Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

2018 Doppler Catalog

Download as pdf or txt
Download as pdf or txt
You are on page 1of 24
At a glance
Powered by AI
Doppler is a Chinese company that develops ultrasonic instruments, probes, and scanning systems. It has received several national and provincial honors.

Doppler offers phased array instruments, probes, scanners, and automatic systems. It can customize special probes and instruments.

Doppler has received ISO 9001 quality management certification, CE certification, and EN12668 standard compliance certification. It has also received several national and provincial science and technology awards in China.

Company Profile Contents

Guangzhou Doppler Electronic Technologies Co., Ltd. is a high-tech enterprise engaged in R&D, manufacturing of ultrasonic Company Profile
instruments & transducers (probes), and is committed to provide high-level solutions to the nondestructive testing industry. The
company's products cover phased array instruments, probes, scanners and automatic systems, with the capability of customize all
kinds of special probes, phased array instruments. A variety of products meet the advanced international level. Instruments
At present, Doppler has built production lines with advanced level and passed the ISO 9001: 2008 quality management system
certification, CE certification and EN12668 standard compliance certification. Doppler is the first enterprise that has established Phascan Portable Ultrasosic Phased Array Flaw Detector ............................ 03
advanced probe production line, also has developed the domestic first phased array unit. Flexscan Compact Portable Phased Array Detector ................................ 04
Anyscan-36/30/20 Digital Ultrasonic Flaw Detector ........................................... 07
Doppler will continue to focus on industrial non-destructive testing industry, promote advanced technology development and industry
standards establishing, and strive to build a high level, diversified modern enterprise.
Phased Array Probes
Linear Small Series .................. 09 DLA/DMA .............................. 14
Wedge Integrated Series .............. 09 Wheel Series ........................... 15
Linear Medium Series ................. 10 Flexible Array Series .................... 16
Linear Large Series ................... 11 Complicated Workpiece Probe ............ 16
Linear Immersion Series ............... 12 Connectors and Cables ................. 17
Matrix 2D/1.5D ........................ 12 Adaptors & Extension Cables ............ 18
Laterally Focused Array ................. 13 Wedge & Protective Film ............... 19
Concave Array Concave Series ......... 14

Ultrasonic Probes
Doppler has received numerous national,provincia and ministerial honors over several years of development.
Normal Beam Probe ................... 21 TOFD Probe ............................ 27
Soft Protective Membrane Probe ........ 22 PVDF Piezoelectric Thin Film Probe ....... 28
Dual Element Probe ................... 23 High Frequency Self Focusing Probe ...... 28
Angle Beam Probe .................... 24 TRL Probe ............................ 29
Delay Line Probe ...................... 25 Custom and Special Probe .............. 30
Immersion Probe ...................... 26 Probe Cable ........................... 30

Scanners
PA+TOFD Scanner FC-01 ..................................................................... 31
Bracelet Scanner CRS-1/CRS-2/CRS-3 .......................................................... 31
Science and technology achievement award
HIGH-Tech Enterprise of China National key new product certificate
of China Instrument and meter Association PA+TOFD Scanner FC-02 ..................................................................... 32
PA+TOFD Scanner FC-02+ .................................................................... 33
MOS-01 Mouse Type Girth Weld Scanner ....................................................... 33
CCE-2 Single Probe Mini Scanner .............................................................. 34
MOS-02 Mouse Type TKY Conner Weld Scanner ................................................. 34
MOS-03 Mouse Type PA/TOFD Dual Probes Scanner .............................................. 34
MINI Scanner:DSC-01 / DSC-02 ............................................................... 35
GECKO Automated Crawler Scanner ........................................................... 36

Automatic Systems
Certificate of National CE Certificate Certificate of Adopting Guangdong province European EN-12668 ISO9001 Quality Managemet System Certification
Torch Program project International Standard high tech product certificate Standard Compliance
Product Mark Certificate Multichannel Ultrasonic Inspection System ....................................................... 37
Powerscan 256 ........................................................................... 38
01 www.cndoppler.com
02

Benefit of Human Security and Healty


Service to the Community for the
CORPORATE MISSION
Culture Strong Technology

Mission
Service to the Community for the Benefit to Human Safety and Health Probe frequency range: 0.2 MHz ~ 20 MHz.

Probe elements optional range: 4 ~ 1024 elements


Vision
Creating a World-Class Ultrasound Brand Elements array mode: Linear, Matrix, Concave, 1.5D Matrix, Annular, Internal focused, etc.

With the ability to process piezoelectric single crystal composite materials and transducers
Core Values Phased array instrument channel: 256 / 256PR
Love, Integrity, Innovation, Dedication
With all kinds of scanners for flat plate, pipe weld and base metal inspection

Philosophy
Pursuit of Excellence - Constantly Improving, and Try the Best!
Honest and Trustworthy - Be Sincerely, and Keep the Promise!
Solidarity and Cooperation
- Integrating Resources and Create a Prosperous Business.

A high-level of technical team


World-class equipments
Innovative production methods
Complete quality management

An Innovative Global Enterprise

Quality Control
Complete Quality Management in Production Process。

Quality is the foundation for the company, which is essential for the future.With to the company concept of “Service to the community for the
benefit of human security and health”, all staff in Doppler regard quality as the lifeline, adhering to the principle of “Technology innovation,
consistent improvement, and customer satisfactory” in all processes including product development, production and service, taking zero defect
as the responsibility, combining high-tech and high-quality perfectly, and building a renowned world brand of ultrasound .

Quality Management Objectives


Qualified rate of finished products: 100%
Doppler products are designed to offer brilliant qualities to supply NDT Ultrasonic Instruments & probes in the world. Customer satisfaction rate: 95%, annual growth rate of 0.5%
With Doppler's strong technology power, products are well accepted by the domestic & oversea markets, such as Product one-time inspection pass rate: 95%, annual growth rate of 0.5%
USA, Germany, UK, France, Japan, Israel, Czech, Russia, India, Argentina, Korea, Indonesia, etc. Due to our Wrong or missing inspection on delivered goods: 0
excellent R&D teams and advanced production lines, Doppler's UT flaw detectors & UT probes have been ISO9001: 2008 Quality Management System Certification
accepted and well commented in every international NDT fairs. Doppler is the first company that passes EU EN12668 standard
Doppler is powered by senior UT experts, oversea Doctors, and a group of young engineers to form a professional conformance certification in China
team with technologies in acoustics, material science, electronics, mechanical & application sectors, and also
employ UT experts as consultants from US famous universities. Together to develop & create a world-class NDT
Ultrasonic Instruments & probes company, and build a renowned world-brand of ultrasonic.
www.cndoppler.com PAGE- 04
Portable Phased Array Flaw Detector
Linear-Scan Sectorial-Scan

2017 New Upgrade,


Support AutoCAD Import Function!

16/64;32/64;32/128;32/128PR pulser/receiver channels for phased array.


Dual independent channels for high-performance TOFD detection.
Embedded focal law calculator, which can perform: Reporting Phascan Offline Data Analysis
With four kinds of scanning methods linear, sectorial, depth and static. and Reporting Software
True depth, Sound path, Projection, and Focal Plane four kinds of focus types available. The Phascan is designed to inspect, analyse and generate
reports directly on the instrument, or off-line on computer.
Optional display mode of A / S / B / C, etc. This offline software is the perfect PC-based
software companion to the Phascan
Calibration is more convenient to implement and can be calibrated for each beam. instruments, and seamlessly imports Phascan
Multiple group for parallel scanning, equivalent of more than one instrument working simultaneously. files foradvanced processing and analysis in it.
Negative square-wave emission, with resolution up to 2.5ns, PRF up to 20KHz.
10.4" TFT LCD color touch screen, resolution 800*600 pixel.

FLEXSCAN Portable Phased Array Detector

lighter, more compact


conventional UT, TOFD, 32 / 64PR phased array
support XY two dimensional scanner
a variety of welds can be selected
8.4 inch touch screen
Phased Array Typical Application Case Performance www.cndoppler.com PAGE- 06
Parameter PA module Conventional UT

Receiver / Pulser 32/128 2/4


Config. Range 9900μs 9900μs

Velocity 635-15240m/s 635-15240m/s


Focal Law 1024
Turbine Leaf Root Inspection GIS Straight Conductor Weld Inspection
Test Mode PE / PC PE / PC / TT / TOFD
Voltage 50V / 100V 50V / 100V / 200V
Pulse Shape Negative Square Wave Negative Square Wave
Pulse Width 30-500ns 30-500ns
Pulser
Rise Time <8ns <8ns
20KHz 20KHz
Delay 10μs / 2.5ns 10μs / 2.5ns
Damping NA 50Ω/ 500Ω

Weld Penetration Measurement of Gain 0-80dB 0-80dB


Stainless Steel in Nuclear Power Plant Polyethylene Pipe Joint
Bandwidth 0.5-15MHz 0.5-15MHz
Receiver Input Impendance 200Ω 200Ω
Input Capacitance 60pF 60pF
Delay 10μs / 2.5ns 10μs / 2.5ns
Type Linear/Sectorial/Static/Depth NA
Scan/Display Display Mode A/B/C/S A/B TOFD
Unit mm / inch mm / inch
DAC Points 16
Points 16
TCG Dynamic Range 40dB
Composite Material Inspection Aerospace Propulsion Shell
Max Gain Slope 40dB/μs
Gates A/B/I
Gate Threshold 0-98%
Trig Mode Peak / Edge
Report HTML
Data Storage Storage Devices USB Devices / SD Card

Size 10.4 inch


Display Screen Resolution 800*600 pixel

Complex Surface Inspection Type TFT LCD Touch Screen


Flange Inspection USB 3
Internet 10/100M
I/O Port
Video Output DVI / VGA Compatible
Encoder Applicable
Language English / Chinese
Power Supply 15V DC 4A
Battery Lithiumlon Battery
Power Supply
Charging Operatable While Charging
Battery Life 6h
Dimensions 325mm*230mm*130mm
Housing
Weight 4.5Kg (without battery)
www.cndoppler.com PAGE- 08
Anyscan - 20/30/36 Ultrasonic Flaw Detector
Ordering Instructions
Conventional Ultrasonic Phased Array transducer frequency is 1MHz ~15MHz. Element quantity is from 8 to 128, custom order can be up to
1024 elements. In this handbook, contains full information of transducers including Linear(L), Matrix(M), Annular(A), Concave(C), Wedge
Integrated and so on. Other type of transducers can be customized according to customers’requirements. Wedges, connectors, connector
Professional Manufacturer switchs and extension cables also can be customized.
Of Ultrasonic Instruments & Transducers

Linear(L) Internal Focused(S) 1.5D Array(M) 2D Array(M) Convex(V) Concave (C )

Annular(A) Annular Sectorial(S) Variable angle(L) Skew(S) Dual linear(S) Dual 1.5(S)

6
nyscan - 3 A: Active aperture Px:Primary Pitch
A g:Internal element spacing Py:Secondary Pitch
W:Element width Iex:Primary element spacing
p:Elementary pitch Iey:Secondary element spacing
E:Elevation Lx:Primary Aperture
Ly:Secondary Aperture
n:Number of elements in the PA probe

nyscan - 30 Active aperture:A = 2n × p

A Precise active aperture: A = (n - 1)× p + W


Near field:N =D /(4λ)

Anyscan - 20
Probe Model Illustration:
L B U
Frequency Array No. Pitch Elevation Probe Casing Cable Cable Cable Connector
type elements type type
Comparison type jacket
type
capacitance
(/m)
length

Instrument model
A20 A30 A36
Wedge Model Illustration:
SB 6 - N 55 S - I H C - AOD 50
Comparison function
Wedge Mounting Refraction Wave Irrigation Scanner yoke Adjustable Radius Tube
Spike wave √ √ √
type method angle type attachment carbide type diameter
Square wave √
points wear pins
Weld graph illustration √ √ √
Series storage √ √ √
RF √ √ √ Probe Model Illustration Wedge Model Illustration
Chinese/English √ √ √
Peak holding √ √ √ Frequency :1=1MHz 2=2MHz 3.5=3.5 MHz 5=5 MHz 7.5=7.5 MHz 10=10 MHz 15=15MHz Wedge Type :S××:Casing type matched to the wedge ××
Array Type :L(linear) V(convex) C(concave) M (matrix ) A(Annular) S(special) Mounting Method :N = Normal
Envelope √ √ √ :64=64 Elements L = Lateral
No. Elements
Surface amend √ √ √ Pitch :0.8=0.8mm(Elementary pitch) Refraction Angle :0=0° 45=45° 55=55°
Auto gain √ √ √ Elevation :10=10mm Wave Type :S=Share Wave  L=Longitudal Wave 
Probe Type :A:Wedge integrated (A45: Integration 45°wedge,A0:Integration 0°wedge) IHC :I=Irrigation
DAC √ √ √ B :Wedge un-integrated contact probe (B1 ,B2 …) H =Scaner yoke attachment points
AVG √ √ R :Radius of concave or convex probe (R29 :Radius 29 ) C =Adjustable carbide wear pins
AWS √ √ I :Immersion probe Radius Type : AOD= Axial outside diameter ( circumferential scan)
:According probe serial  COD=Circumferential outside diameter (axial scan)
Echo compare √ Casing Type P:PVC U:PU ( Required by nuclear industry )
Cable Jacket Type :50=50PF 60=60PF 75=75PF 90=90PF 110=110PF Tube Diameter :50=50mm
Noise immersion √ √ :
Cable Capacitance 2.0=2.0m
Hot key √ √ Cable Length

Shuttle key √ :H1:Hypetronics P1 :Omni Connector 160PIN D3:DL-96P
Connector Type
D1:DL-156P D2:DL-260P M2:MOLEX 160PIN
J1:D38999/26FF35SN M1:MOLEX 78PIN
C1:CONEC 78PIN T1:ITT-cannon QLC260P
Phased Array Probes www.cndoppler.com PAGE- 10

Linear Small Series Linear Medium Series


Applications Features Applications Features
Power: conventional welding inspection, pressure vessels, Tiny outlines
Power: conventional welding inspection, pressure vessels, Cable side leads
oil refineries, etc. Cable top or side leads
Aviation / Aerospace: Welding, landing gears inspection Electronic controls beam angle, focusing, and scanning step size oil refineries, etc. Electronic controls beam angle, focusing, and scanning step size
Automotive: engine parts, frames, axles, brake discs. Fixed angle & focused probes, without the need of multiple detections Aviation / Aerospace: Welding, landing gears inspection Fixed angle & focused probes, without the need of multiple detections
Conventional: Weldings, Forgings, Castings, Pipes, Can detect conventional undetectable areas Automotive: engine parts, frames, axles, brake discs Can detect conventional undetectable areas
Bridges & construal steels Replaceable two types of wedges - flatted & curved surfaces Conventional: Weldings, Forgings, Castings, Pipes, Replaceable two types of wedges - flatted & curved surfaces
Bridges & construal steels

L
W
L W

Specifications and Dimensions B54 B20 B55

Active Casing Dimensions


Frequency Pitch Elevation Case
Model Elements Aperture Long (L) Width (W) Height (H)
(MHz) (mm) (mm) Type
(mm) mm in mm in mm in H
5L10-0.6*6 5 10 0.6 6 6 13 0.51 10 0.39 23 0.91
B54
10L10-0.6*5 10 10 0.6 6 5 13 0.51 10 0.39 23 0.91 L
W
5L8-0.5*5 5 8 0.5 4 5 12 0.47 20.5 0.81 18 0.71
7.5L8-0.5*5 7.5 8 0.5 4 5 12 0.47 20.5 0.81 18 0.71 B20 D1 D2
10L16-0.31*5 10 16 0.31 4.96 5 12 0.47 20.5 0.81 18 0.71
5L16-0.31*5 5 16 0.31 4.96 5 11.5 0.45 11.5 0.45 23 0.91
B55
10L16-0.31*5 10 16 0.31 4.96 5 11.5 0.45 11.5 0.45 23 0.91

Wedge Integrated
Applications Features
Power: conventional welding inspection, pressure vessels, Electronic controls beam angle, focusing, and scanning step size
pipelines, rotor inspection Fixed angle & focused probes, without the need of multiple detections B56 B10
Petroleum: Pipelines, tanks Can detect conventional undetectable areas
Aviation / Aerospace: Composites delamination & Replaceable two types of wedges - flatted & curved surfaces
abhesion, welding, landing gears inspection Specifications and Dimensions
Transportation: Composites delamination & abhesion,
planks Casing Dimensions
Active
Pitch Elevation Case
W

Conventional: Large area scanning; planks, sticks, Frequency


Model (MHz)
Elements Aperture Long (L) Width (W) Height (H)
pipelines thickness measurement
H
H (mm) (mm) Type
(mm) mm in mm in mm in
L

L W 5L8-1.0*9 5 8 1.0 8 9 15 0.59 27 1.06 22 0.87


5L16-0.6*10 5 16 0.6 9.6 10 15 0.59 27 1.06 22 0.87 D1
7.5L16-0.5*10 7.5 16 0.5 8 10 15 0.59 27 1.06 22 0.87
2.5L32-0.5*10 2.5 32 0.5 16 10 21 0.83 28 1.10 22 0.87
A36( side) A36( top) A37.5 5L32-0.5*10 5 32 0.5 16 10 21 0.83 28 1.10 22 0.87 D2
Specifications and Dimensions 7.5L32-0.5*10 7.5 32 0.5 16 10 21 0.83 28 1.10 22 0.87

Active Casing Dimensions 2.5L16-1.0*10 2.5 16 1.0 16 10 21 0.83 33.5 1.32 38.5 1.52
Frequency Pitch Elevation Case 4L32-0.5*10 4 32 0.5 16 10 21 0.83 33.5 1.32 38.5 1.52
Model (MHZ)
Elements Aperture Long (L) Width (W) Height (H)
(mm) (mm) Type B10
(mm) mm in mm in mm in 7.5L32-0.5*10 7.5 32 0.5 16 10 21 0.83 33.5 1.32 38.5 1.52
4L16-0.5*9-A37.5 4 16 0.5 8 9 27 1.06 16.5 0.65 22 0.87 A37.5 10L16-1.0*10 10 16 1.0 16 10 21 0.83 33.5 1.32 38.5 1.52
5L12-0.5*6-A36(side) 5 12 0.5 6 6 25 0.98 13 0.51 9.7 0.38 A36(side 5L16-0.6*10 5 16 0.6 9.6 10 16 0.63 23 0.91 20 0.79
5L12-0.5*6-A36(top) 5 12 0.5 6 6 18 0.71 13 0.51 19.7 0.78 A36(top) 7.5L16-0.6*10 7.5 16 0.6 9.6 10 16 0.63 23 0.91 20 0.79 B56
5L12-0.5*6-A40 5 12 0.5 6 6 25 0.98 15 0.59 9 0.35 A40 10L32-0.3*7 10 32 0.3 9.6 7 16 0.63 23 0.91 20 0.79
Phased Array Probes www.cndoppler.com PAGE- 12

Linear Large Series Linear Immersion Series


Applications Features Applications Features
Power: pressure vessels, Pipelines. Electronic controls beam angle, focusing, and scanning step size Power: pressure vessels, Pipelines. Electronic controls beam angle, focusing, and scanning step size
Petroleum: Pipelines, tanks Less settings and scanning time Petroleum: Pipelines, tanks Less settings and scanning time
Aviation / Aerospace: Composites delamination & abhesion, Electronic focusing – Increased sensitivities & Signal-to-noise ratios Aviation / Aerospace: Composites delamination & Electronic focusing – Increased sensitivities & Signal-to-noise ratios
welding, landing gears inspection Reduction or Exemption of mechanical or manual controls abhesion,welding, landing gears inspection Reduction or Exemption of mechanical or manual controls
Transportation: Composites delamination & abhesion, planks Wedges may replaceable when Immersion method applied Transportation: Composites delamination & abhesion, planks Wedges may replaceable when Immersion method applied
Conventional: Large area scanning; planks, sticks, pipelines Conventional: Large area scanning; planks, sticks, pipelines
thickness measurement thickness measurement
H

D27 B60
Specifications and Dimensions
Active Casing Dimensions
Frequency Pitch Elevation Case
D3 B26 D7 Model Elements Aperture Long (L) Width (W) Height (H)
(MHz) (mm) (mm) Type
(mm) mm in mm in mm in
5L128-0.8*10 5 128 0.8 102.4 10 120 4.72 16 0.63 30 1.18 B60
5L128-1.0*10 5 128 1.0 128 10 134 5.28 16 0.63 35 1.38 D27

H
H

L
W
L W
L Matrix 2D/1.5D
Applications Features
Power: conventional welding inspection, pressure vessels, Electronic controls beam angle, focusing, and scanning step size
pipelines, rotor inspection Fixed angle & focused probes, without the need of multiple detections
B7 B6/ B23/ B40 B57 D6
Petroleum: Pipelines, tanks Can detect conventional undetectable areas
Aviation / Aerospace: Welding, landing gears inspection Replaceable two types of wedges - flatted & curved surfaces
Specifications and Dimensions Automotive: engine parts, frames, axles, brake discs Immersion method applicable
Casing Dimensions Conventional: Weldings, Forgings, Castings, Pipes, Bridges &
Active
Frequency Pitch Elevation Case construal steels 3D imaging applicable
Model (MHz)
Elements Aperture Long (L) Width (W) Height (H)
(mm) (mm) Type
(mm) mm in mm in mm in
2.25L64-0.6*10 2.25 64 0.6 38.4 10 45 1.77 28 1.10 28 1.10
5L64-0.6*10 5 64 0.6 38.4 10 45 1.77 28 1.10 28 1.10 D3
10L64-0.6*7 10 64 0.6 38.4 7 45 1.77 28 1.10 28 1.10
2.25L32-1.0*20 2.25 32 1.0 32 20 36 1.42 36 1.42 28 1.10 B15/16/19
D6
2.25L32-0.8*22 2.25 32 0.8 25.6 22 36 1.42 36 1.42 28 1.10 Specifications and Dimensions
5L128-0.75*10 5 128 0.75 96 10 102 4.02 28 1.10 30 1.18 D7
2.25L64-0.75*10 2.25 64 0.75 48 10 57 2.24 29 1.14 35 1.38 Active Active Casing Dimensions
B6 Frequency Pitch Pitch Case
5L64-0.8*10 5 64 0.8 51.2 10 57 2.24 29 1.14 35 1.38 Model (MHz)
Elements Aperture Aperture Long (L) Width (W) Height (H)
X(mm) Y(mm) Type
5L64-0.6*10 5 64 0.6 38.4 10 44 1.73 28 1.10 34 1.34 B7 X(mm) Y(mm) mm in mm in mm in
7.5L60-1.0*10 7.5 60 1.0 60 10 68 2.68 26.8 1.06 40 1.57 B23 5M8*8-1.0*1.0 5 64 1.0 1.0 8 8 35 1.38 19 0.75 45 1.77
B15
5L64-1.0*10 5 64 1.0 64 10 84 3.31 35.5 1.40 32 1.26 B26 10M4*4-2.0*2.0 10 16 2.0 2.0 8 8 35 1.38 19 0.75 45 1.77
5L32-0.8*12 5 32 0.8 25.6 12 33 1.30 29 1.14 30 1.18 B40 5M8*8-1.5*1.5 5 64 1.5 1.5 12 12 34 1.34 20 0.79 47 1.85 B19
5L64-0.6*10 5 64 0.6 38.4 10 45 1.77 23 0.91 20 0.79 5M16*16-1.0*1.0 5 256 1.0 1.0 16 16 40 1.57 27 1.06 55 2.17 B16
B57
10L64-0.6*7 10 64 0.6 38.4 7 45 1.77 23 0.91 20 0.79 15M8*8-1.25*1.25 15 52 1.25 1.25 10 10 25 0.98 22 0.87 30 1.18 D21
Phased Array Probes www.cndoppler.com PAGE- 14

Laterally Focused Array Concave Series

Features Features
Electronic controls beam angle, focusing, and scanning step size
Tiny Outlines
Less settings and scanning time
Sel-Focusing Elements Electronic focusing – Increased sensitivities & Signal-to-noise ratios
Wedge suitable for Φ20-Φ115mm Pipes Reduction or Exemption of mechanical or manual controls
Suitable for Automatic Scanning Systems Wedges may replaceable when Immersion method applied

Applications
Applications Power: pressure vessels, Pipelines.
Petroleum: Pipelines, tanks
R9

Aviation / Aerospace: Composites delamination & abhesion, welding, landing gears inspection
Small diameter pipes inspection Transportation: Composites delamination & abhesion, planks
Thin pipe or plate welds inspection Conventional: Large area scanning; planks, sticks, pipelines thickness measurement
Friction stir welds inspection
Limited space workpiece inspection

R1/5/7/8
Specifications and Dimensions
Active Casing Dimensions
Frequency Pitch Radius Elevation Case
Model (MHz)
Elements Aperture Long (L) Width (W) Height (H)
(mm) R (mm) Type
(mm) mm in mm in mm in
3.5C128-0.625*13-R32 3.5 128 0.625 R32 80 13 111 4.37 19 0.75 56 2.20 R8
3.5C96-0.6*12-R22.9 3.5 96 0.6 R22.9 57.6 12 95.1 3.74 19 0.75 52 2.05 R7
4C64-1.0*10-R50 4 64 1.0 R50 64 10 124 4.88 18 0.71 60 2.36 R1
10C64-1.0*10-R29 10 64 1.0 R29 64 10 106 4.17 18 0.71 47 1.85 B5

DLA / DMA

Suitable for Austenitic, Nickel, and Other Coarse Grain Alloys


Friction stir welds Small diameter pipe welds GIS Line conductor

Specifications and Dimensions


Specifications and Dimensions
Active Casing Dimensions
Frequency Pitch Elevation Case Casing Dimensions
Model Elements Aperture Long (L) Width (W) Height (H) Frequency Px Py Lx Ly Lx*Ly Case
(MHz) (mm) (mm) Type Model Elements Long (L) Width (W) Height (H)
(mm) mm in mm in mm in (MHz) (mm) (mm) (mm) (mm) (mm) Type
mm in mm in mm in
5S16-0.5*10 5 16 0.5 8 10 25 0.98 22 0.87 10 0.39
4DM16*2-1.0*3.0 4 Dual 32 1.0 3 16 6 96 29 1.14 10 0.39 20 0.79 E73
7.5S16-0.5*10 7.5 16 0.5 8 10 25 0.98 22 0.87 10 0.39
D10 2.25DM7*4-2.71*3.0 2.25 Dual 28 2.71 3 18.97 12 227.64 34 1.34 17 0.67 25 0.98 G19
10S16-0.5*10 10 16 0.5 8 10 25 0.98 22 0.87 10 0.39
1.5DL32-2.0*20 1.5 Dual 32 / / / / / 86 3.39 26 1.02 30 1.18 D8
10S16-0.3*10 10 16 0.3 4.8 10 25 0.98 22 0.87 10 0.39
2.25DL16-1.2*12 2.25 Dual 16 / / / / / 34 1.34 17 0.67 31 1.22 D96
D96
Phased Array Probes www.cndoppler.com PAGE- 16

Wheel Series Flexible Array Series


Applications
Features
Delamination, debonding of Composites
Corrosion Inspection of Plates
Axial Direction Corrosion Inspection of Large Diameter Pipes Suitable for uneven surface, variable curvature
With thickness of 3.0mm, suitable for narrow space inspection

Tire Parameter
Outer Diameter 70mm / 90mm
Thickness 8 ~ 15mm (8: 5MHz; 15: 1 or 2MHz) Applications
Length 70mm / 120mm
Impedance 1.5MRayl Complex curvature workpiece inspection

Material Attenuation 0.14dB / mm / MHz Narrow space workpiece inspection


On-site inspection

Specifications and Dimensions


Active
Frequency Pitch Elevation
Model (MHz)
Elements Aperture
(mm) (mm) (mm)

5S64-1.0*10 5 64 1.0 64 10
7.5S32-0.5*10 7.5 32 0.5 16 10

Features & Applications (Variable Angle Wheel Probe)


Complicated Workpiece Probe
Variable Angles
Axis Direction Corrosion Inspection for Diameter Over 100mm Pipes
Delamination, Debonding Inspection of Composites
Corrosion Inspection of Plates
Applications
For Flat & Curved Combined Surface inspection

Specifications and Dimensions


Specifications and Dimensions
Active Casing Dimensions
Frequency Pitch Elevation Case
Model Elements Aperture Long (L) Width (W) Height (H) Active Casing Dimensions
(MHz) (mm) (mm) Type Frequency Pitch Elevation Case
(mm) mm in mm in mm in Model Elements Aperture Long (L) Width (W) Height (H)
(MHz) (mm) (mm) Type
5L64-0.8*6.4 5 64 0.8 51.2 6.4 60 2.4 14 0.55 35 1.38 B18 (mm) mm in mm in mm in
5L128-0.8*6.4 5 128 0.8 102.4 6.4 112 4.4 14 0.55 35 1.38 B60 5S16-0.5*10 5 16 0.5 8 10 25 0.98 22 0.87 10 0.39 R11
Adapters & Extension Cables www.cndoppler.com PAGE- 18

Connectors Phased Array Adapters & Extension Cables


Doppler provides the most compatible connectors for all kind of Phased Array Probes in the
market.

C1 : CONEC(TD) M1 : MOLEX T1 : QLC260P


J1(Male)-P1(Female) P1(Male)-H1(Female) P1(Male)-[2xP1(Female)+4xLemo00]
P1(Probe)-J1(Instrument-Isonic) H1(Probe)-P1(Instrument-Omniscan) 2xP1(Probe)-P1(Instrument-Omniscan)

P1 : Omni Connector 30056 H1 : Hypertronic J1 : D38999

T1(Male)-2T1(Female) T1(Male)-P1(Female) T1(Male)-J1(Female)


2T1(Probe)-T1(Instrument-Phascan) P1(Probe)-T1(Instrument-Phascan) J1(Probe)-T1(Instrument-Phascan)

D2 : DL-260P D2 : DL-260P(C) R1 : HIROSE

D1 : DL-156P D3 : DL-96P© D3 : DL-96P


P1(Male)-T1(Female) T1(Male)-D1(Female) H1(Male)-T1(Female)
T1(Probe)-P1(Instrument-Omniscan) D1(Probe)-T1(Instrument-Phascan) T1(Probe)-H1(Instrument-Dynary)

Cable Types
We select the best coaxial cable from world famous brands, with excellent performance.

Cable Type 50 Ohm coaxial cable with dual shield


Long service life cables Probe Elements 16 64 128 192
Low signal attenuation
Good flexibility Diameter of Cable 4.0 mm 5.9 mm 6.8 mm 8.0 mm
Great mechanical performance Color Black / Ivory
Compatible to most of industrial environment J1(Male)-T1(Female) D3(Male)-D3(Female)(TDscan) H1(Male)-T1(Female)(Isonic)
Jacket Material PVC / PU
T1(Probe)-J1(Instrument-Isonic) 5m, 10m, 15m 5m, 10m, 15m
Wedge Specifications 20
www.cndoppler.com PAGE-

Wedge Wedge Specifications and Dimensions

AXIAL OUTSIDE DIAMETER CIRCUMFERENTIAL OUTSIDE DIAMETER


AOD COD

Features
 0°, 45°, 55°and 60°, and more refractable angles
 SW or LW detection of steel angle from 30° to 70°
 Wedges fixed by stainless screws
 Can Auto-scan with IHC wedges
AXIAL INSIDE DIAMETER SPHERICAL OUTSIDE DIAMETER
 Rotatable in fixed way AID SOD

 Wedge shapes and parameters can be customized

Wedge Parameters Format


CIRCUMFERENTIAL INSIDE DIAMETER SPHERICAL INSIDE DIAMETER
Wedge parameters with OmniScan ○ R

CID SID
X Primary offset
Y Secondary offset (0 when probe is centered) Refraction Dimension (mm)
Model Case Scan Angle Angle
Angle in Steel L H W
Z Height
SB10 -N0L(20mm) B10 0°LW -15°
~15° 21.00 33.60 20.00 0°
SB10 -N45L B10 45°
°LW 30°~60° 31.64 33.50 32.35 16.5°
SB10 -N45S B10 45°SW 30°~60° 32.60 33.50 19.51 30°
Wedge parameters with TomoView
TM

SB10 -N55S B10 55°SW 40°~70° 32.60 33.50 18.50 36°


XT Primary axis offset of the middle of the first element (mm) SB10 -N60S B10 60°SW 32.60 33.50 20.78 38°
45°~70°
Y Secondary axis offset of the middle of the first element SD1 -N0L D1 0 °LW -15°
~15° 23.00 30.00 20.00 0°

Z Height at the middle of the first element (mm) SD1 -N45L D1 45°LW 30°~60° 30.00 30.00 24.00 16.5°
SD1 -N45S D1 45°SW 30°~60° 25.50 30.00 15.00 30°
SD1 -N55S D1 55°SW 40°~70° 24.60 30.00 15.30 36°
SD1 -N60L D1 60°LW 45°~70° 30.00 30.00 20.60 20°
SD1 -N60S D1 60°SW 45°~70° 25.50 30.00 15.00 38 °
Wedge parameters with ISONIC SD2 -N0L D2 0 °LW -15°
~15° 31.00 30.00 20.00 0°
W2 The length of wedge SD2 -N0L-IHC D2 0 °LW -15°
~15° 31.00 42.50 20.00 0°
SD2 -N45L D2 45°LW 30°~60° 30.72 30.00 29.25 16.5°
The distance from center of the first
Probe offset element to edge SD2 -N45S D2 45°SW 30°~60° 32.60 30.00 19.50 30°
SD2 -N55S-IHC D2 55°SW 40°~70° 32.60 42.00 18.50 36°
H2 The minimum height of wedge
SD2 -N55S D2 55°SW 40°~70° 32.60 30.00 18.50 36°
SD2 -N60L D2 60°LW 45°~70° 30.69 30.00 24.93 20°
SD2 -N60S D2 60°SW 45°~70° 32.60 30.00 18.93 38 °
SD3 -N0L D3 0°LW -15°
~15° 62.00 30.00 20.00 0°

High Acoustic Penetration Protective Film (Replacement of Wedge) SD3 -N45L D3 45°LW 30°~60° 62.28 30.00 54.89 16.5°
SD3 -N45S D3 45°SW 30°~60° 66.31 30.00 41.88 31°

Use High Acoustic Penetration Protective Film, can be attached to contact surface SD3 -N55S D3 55°SW 40°~70° 63.74 30.00 36.51 36 °
SD3 -N60L D3 60°LW 45°~70° 60.94 30.00 54.83 20°
of PA probe with no need of 0°wedge, which is effectively reduce the multi-echo
SD3 -N60S D3 60°SW 45°~70° 66.51 30.00 36.07 39°
noise interference by the wedge, can save inspection cost effectively. SD10-N60S-IH-AODXX D10 60°SW 45°~70° 18.00 22.00 12.00 39°
SD10-N60S-IH-CODXX D10 60°SW 45°~70° 18.00 22.00 12.00 39°
Ultrasound Probes www.cndoppler.com PAGE- 22

Normal Beam Probe Soft Protective Membrane Probe

A B C
Dimension
mm in mm in mm in
No.1 20 0.8 42 1.7 25 1.0
No.2 25 1.0 47 1.9 35 1.4
No.3 30 1.2 59 2.3 45 1.8
A B C
Dimension
mm in mm in mm in
No.1 20 0.8 42 1.7 25 1.0
No.2 25 1.0 47 1.9 35 1.4
A B No.3 30 1.2 59 2.3 45 1.8
Dimension
mm in mm in
No.4 34 1.3 49.5 1.9 55 2.2
No.4 16 0.6 12 0.5
No.5 25 1.0 17 0.7
No.6 29 1.1 18 0.7
No.7 33 1.3 24.5 1.0

Applications Applications
General applications, large parts with simple shapes
General applications, simple structural metal parts
Forgeable pieces and castings
Detection of plank stuffs, large forgings, blank materials, castings
Plank stuffs and bar materials

Performance Features
Performance Features
Good abrasion resistance
Replaceable protective films, convenient to coupling on uneven surface of workpiece, extended lifetime of probes.
BNC(Q9), Q6 connectors, applied for Domestic, and American standards
LEMO-00 (C5), LEMO-1(9) connectors
LEMO-00 (C5), LEMO-1 (C9), Microdot (L5) connectors, applied for European standard

Specific Models & Parameters


Frequency Crystal Size Near Field

Echo Wave & Spectrum Specific Models & Parameters Echo Wave & Spectrum Model
MHz in mm
Length
in mm
Dimension Remarks

Frequency Crystal Size Near Field Length


PF1P10N 1 0.39 10 0.2 4
Model Dimension Remarks
MHz in mm in mm PF2P10N 2 0.39 10 0.3 8
No.1
N5P5L 5 0.20 5 0.2 5 PF4P10N 4 0.39 10 0.7 17
N10P5L 10 0.20 5 0.4 10 No.4
PF5P10N 5 0.39 10 0.8 21
N10P6L 10 0.24 6 0.6 15
N 1P10 L 1 0.39 10 0.2 4
PF1P20N 1 0.79 20 0.7 17
N 2P10 L 2 0.39 10 0.3 8 PF2P20N 2 0.79 20 1.3 34
No.1 / No.5 No.2
N 4P10 L 4 0.39 10 0.7 17 PF4P20N 4 0.79 20 2.7 68
N 5P10 L 5 0.39 10 0.8 21
PF5P20N 5 0.79 20 3.3 85
N 10P10 L 10 0.39 10 1.7 42
N 1P20 L 1 0.79 20 0.7 17 PF0.5P24N 0.5 0.94 24 0.5 12
N 2P20 L 2 0.79 20 1.3 34 PF1P24N 1 0.94 24 0.9 24
N1P10L 4 0.79 20 2.7 68 No.2 / No.7
PF2P24N
N 4P20 L PF2P24N 2 0.94 24 1.9 49 No.3
N 5P20 L 5 0.79 20 3.3 85
PF4P24N 4 0.94 24 3.8 97
N 1P24 L 1 0.94 24 0.9 24
N 2P24 L 2 0.94 24 1.9 49 No.3
PF5P24N 5 0.94 24 4.8 122
N 4P24 L 4 0.94 24 3.8 97 PF0.5P40N 0.5 1.57 40 1.3 34 No.4
N 5C10 L 5 0.39 10 0.8 21 No.1 / No.5 PF2C10N 2 0.39 10 0.3 8
N 1C20 L 1 0.79 20 0.7 17
Composite PF4C10N 4 0.39 10 0.7 17 No.1
N 2C20 L 2 0.79 20 1.3 34 No.2 / No.7
N 4C20 L 4 0.79 20 2.7 68
Crystal PF5C10N 5 0.39 10 0.8 21
N 1C24 L 1 0.94 24 0.9 24 PF1C20N 1 0.79 20 0.7 17
No.3 No.2
N 2C24 L 2 0.94 24 1.9 49 PF2C20N 2 0.79 20 1.3 34
PF1C24N 1 0.94 24 0.9 24
Note: type the order arranged in the chip size, special models can be customized No.3
PF2C24N 2 0.94 24 1.9 49

N4P24L PF5P20N Note: type the order arranged in the chip size, special models can be customized
Ultrasound Probes www.cndoppler.com PAGE- 24

Dual Element Probe Angle Beam Probe

A B C
Dimension
mm in mm in mm in
A B C
Dimension No.1 20 0.8 16 0.6 12 0.5
mm in mm in mm in
No.2 29 1.1 22 0.9 14 0.6
No.1 20 0.8 42 1.7 25 1.0
No.3 28 1.1 22 0.9 16.5 0.6
No.2 25 1.0 47 1.9 35 1.4
No.4 32 1.3 23 0.9 18.5 0.7
No.3 30 1.2 59 2.3 45 1.8
No.5 44 1.7 30 1.2 19 0.7
No.6 54 2.1 38 1.5 25 1.0

A B C
A B Dimension
Dimension mm in mm in mm in
mm in mm in
Applications No.4 29 1.1 18 0.7 Applications No.7 27 1.1 22 0.9 17 0.7
No.8 36 1. 4 30.5 1.2 21 0.8
No.5 33 1.3 24.5 1.0
Detection of wall thickness margin, rust-eaten, corrosion Common welding inspection No.9 54 2.1 44 1.7 32 1.3
No.6 40 1.6 31 1.2
Near surface flaw detection Pipe casting, pressure vessels, storage tanks
Small Parts – screws, bolts, pins Turbine blades
Inspection of weld overlay & cladding bond Wheel axles, forgings, and castings parts
Adhesive detection Train wheels, and railway tracks
Train wheels
Shafts, rods, billet cores defects

Performance Features Angle Beam Probe


BNC (Q9), Microdot (L5) connectors, applied Specific Models and Parameters
Performance Features
for Domestic, and American standards
Frequency a×b β Focus Length
Excellent near surface resolution LEMO-00 (C5), LEMO-1 (C9) connectors, Model Dimension Remarks
MHz in mm Steel in mm
Small scattered noise applied for European standard
2P8×9A45 2 0.31×0.35 8×9 45 0.6 15
Q6 connector, applied for Domestic, and American
2P8×9A60 2 0.31×0.35 8×9 60 0.6 15
standards
LEMO-00 (C5), Microdot (L5) connectors, applied for Specific Models & Parameters 2P8×9A70 2 0.31×0.35 8×9 70 0.6 15
No.7
4P8×9A 45 4 0.31×0.35 8×9 45 1.2 30
European standard
4P8×9A60 4 0.31×0.35 8×9 60 1.2 30
Frequency a×b Focus Length
Model Dimension Remarks
MHz in mm in mm Echo Wave & Spectrum 4P8×9A70 4 0.31×0.35 8×9 70 1.2 30

Echo Wave & Spectrum DA2.5P20FS10 2.5 0.79 Φ20/2 0.4 10 5P9×9A45 5 0.35×0.35 9×9 45 1.7 42
DA2.5P20FS15 2.5 0.79 Φ20/2 0.6 15
5P9×9A60 5 0.35×0.35 9×9 60 1.7 42 No.2
DA2.5P2 0FS20 2.5 0.79 Φ20/2 0.8 20
No.5
DA2.5P20FS25 2.5 0.79 Φ20/2 1.0 25 5P9×9A70 5 0.35×0.35 9×9 70 1.7 42
DA2.5P20FS30 2.5 0.79 Φ20/2 1.2 30 2P14×14A45 2 0.55×0.55 14×14 45 1.5 39
DA5P20FS15 5 0.79 Φ20/2 0.6 15
2P14×14A60 2 0.55×0.55 14×14 60 1.5 39
DA2.5P25FS10 2.5 1 Φ25/2 0.4 10
No.6
DA5P25FS10 5 1 Φ25/2 0.4 10 2P14×14A70 2 0.55×0.55 14×14 70 1.5 39
No.8
DA2P3.5×10FS8 2 0.14×0.39 3.5×10 0.3 8
4P14×14A45 4 0.55×0.55 14×14 45 1.5 39
DA2P3.5 ×10FS10 2 0.14×0.39 3.5×10 0.4 10
500 mV/Div 250n S/Div 3dB/Div 1MHz/Div 4P14×14A60 4 0.55×0.55 14×14 60 1.5 39
DA2P3.5 ×10FS18 2 0.14×0.39 3.5×10 0.7 18
DA5P20FS35 DA4P3.5 ×10FS10 4 0.14×0.39 3.5×10 0.4 10 No.1 2.5P13×13A70 4P14×14A70 4 0.55×0.55 14×14 70 1.5 39
DA4P3.5 ×10FS18 4 0.14×0.39 3.5×10 0.7 18 2P20×22A45 2 0.79×0.87 20×22 45 3.6 92
DA5P9FS 25 5 0.35 Φ9/2 1.8 25
2P20×22A60 2 0.79×0.87 20×22 60 3.6 92
DA2P11FS8 2 0.43 Φ11/2 0.3 8
DA2P7 ×18FS15 2 0.28×0.71 7×18 0.6 15 2P20×22A70 2 0.79×0.87 20×22 70 3.6 92 No.9
DA2P7×18FS30 2 0.28×0.71 7×18 1.2 30
4P20×22A45 4 0.79×0.87 20×22 45 7.2 184
DA4P6 ×20FS12 4 0.24×0.79 6×20 0.5 12 No.3
4P20×22A60 4 0.79×0.87 20×22 60 7.2 184
DA4P6 ×20FS25 4 0.24×0.79 6×20 1.0 25
DA1P21FS20 1 0.83 Φ21/2 0.8 20

50 mV/Div 250n S/Div 3dB/Div 1MHz/Div 500 mV/Div 500n S/Div 3dB/Div 1MHz/Div
Note: type the order arranged in the chip size, special models can be customized Note: type the order arranged in the chip size, special models can be customized
DA4P3.5×10F18 4P8×9A45
Ultrasound Probes www.cndoppler.com PAGE- 26

Delay Line Probe Immersion Probe

A B C
Dimension
mm in mm in mm ft
Drawing 1 9.5 0.4 45 1.8 1.8 5.9
Drawing 2 15 0.6 50 2.0 1.8 5.9
A B C Drawing 3 19 0.7 53 2.1 1.8 5.9
Dimension
mm in mm in mm in Drawing 4 25 1.0 60 2.4 1.8 5.9
No.1 14 0.6 22.5~29.5 0.9~1.2 7.6 0.3

Applications
Match hydroacoustics performance to raise efficiency.

Applications Realize point focusing (spherical surface) or line focusing (cylinder), raise resolution, sensitivity and signal-to-noise ratio.
BNC(Q9) connector or with cable.
 Thickness measurement
 Near surface flaw detection
 Thin materials flaw detection Performance Features
With anomalous or complex geometrical shape components.
Automated system.
For application situation requires high resolution detection.
Performance Features
 Excellent near flaw resolution
Specific Models & Parameters
 Replaceable delay lines, long service life Frequency Ceramic size Near-field length
Model Dimension Remark
 Microdot connector MHZ in mm in mm

l5P6SJ**DJ 5 0.24 6 1.1 29

l5P6SJ**XJ 5 0.24 6 1.1 29


Custom-made for
Echo Wave & Spectrum l10P6SJ**DJ 10 0.24 6 2.3 58 point focusing
Drawing 1 length (not surpass
l10P6SJ**XJ 10 0.24 6 2.3 58 near field length)
l15P6SJ**DJ 15 0.24 6 3.4 87
Echo Wave & Spectrum l15P6SJ**XJ 15 0.24 6 3.4 87

l2.5P10SJ**DJ 2.5 0.39 10 1.6 40


Custom-made for
l2.5P10SJ**XJ 2.5 0.39 10 1.6 40 point focusing
Drawing 2 length (not surpass
l5P10SJ**DJ 5 0.39 10 3.2 81 near field length)
l5P10SJ**XJ 5 0.39 10 3.2 81

DL5P6L l2.5P14SJ**DJ 2.5 0.55 14 3.1 79


Custom-made for
l2.5P14SJ**XJ 2.5 0.55 14 3.1 79 point focusing
Specific Models & Parameters 500 mV/Div 250n S/Div
Drawing 3 length (not surpass
l5P14SJ**DJ 5 0.55 14 6.2 158 near field length)
Frequency Crystal Size Near Field Length
Model Dimension Remarks l5P14SJ**XJ 5 0.55 14 6.2 158
MHz in mm in mm
10P6Y 10 0.24 6 0.6 15 l2.5P20SJ**DJ 2.5 0.79 20 6.3 161
Matching of three types Custom-made for
DL10P6Y - H 10 0.24 6 0.6 15 of delay blocks: l2.5P20SJ**XJ 2.5 0.79 20 6.3 161 point focusing
DL15P6Y 15 0.24 6 0.9 23 9.5mm ( 0.38in ) Drawing 4 length (not surpass
No.1
12.5mm ( 0.5in ) l5P20SJ**DJ 5 0.79 20 12.7 323 near field length)
15P6Y - H 15 0.24 6 0.9 23
16.5mm ( 0.65in )
DL5P6L 15 0.24 6 0.9 23 l5P20SJ**XJ 5 0.79 20 12.7 323
3dB/Div 1MHz/Div

Note: Special type can be customized. I5P10F30 Note: type the order arranged in the chip size, special models can be customized
Ultrasound Probes 28
www.cndoppler.com PAGE-

TOFD Probe PVDF Piezoelectric Thin Film Probe


Echo Wave & Spectrum
A B
Dimension
mm in mm in
Drawing 1 16.5 0.6 10 0.4
Drawing 2 18 0.7 12 0.5

Specific Models & Parameters


Applications Applications
Frequency Ceramic size Near-field length
Usually match with microdot (L5) connetor Model Dimension Remark
MHz in mm in mm Near surface flaw detection 15C8-4(Annular)
(top direction ).
TF5C3N 5 0.12 3 0.1 2 Thin workpiece detection
Drawing 1
TF10C3N 10 0.12 3 0.2 4 High frequency detection and thickness measurement
Performance Features TF2C6N 2 0.24 6 0.1 3
Available for
TF5C6N 5 0.24 6 0.3 8 Drawing 2 A45/A60/A70
Weld detection for boiler, pressure vessel wedges
TF10C6N 10 0.24 6 0.6
and pressure pipe. 15
Performance Features
TF2C10N 2 0.39 10 0.3 8
Drawing 3
TF5C10N 5 0.39 10 0.8 Excellent resolution
Echo Wave & Spectrum 21

It has a very good matching effect with water,


plastic and other low impedance medium 20C7(Circular)
The pulse period is ≤2, with a sufficiently wide frequency band

High Frequency Self Focusing Probe


100 mV/Div 250n S/Div 3dB/Div 1MHz/Div 50 mV/Div 250n S/Div 3dB/Div 2MHz/Div

TF5C6N TF10C3N
Echo Wave & Spectrum
A B C
Model
mm in mm in mm in
TOFD Wedge 22 0.9 12 0.5 15 0.6
Drawing 4
Drawing 5 24 0.9 13 0.5 16 0.6
Drawing 6 26 1.0 14 0.6 22 0.9

Specific Models & Parameters


20C3-YK
β
Model Dimension Remark
Steel
A45-3N 45 Applications
Collocation Probe Model:
A60-3N 60 Drawing 4 Near surface flaw detection Test 0.4mm thin
TF5C3N TF10C3N
A70-3N 70 Thin workpiece detection workpiece echo
A45-6N 45 High frequency detection and
Collocation Probe Model:
A60-6N 60 Drawing 5 thickness measurement
TF2C6N TF5C6N TF10C6N
A70-6N 70
A45-10N 45 Performance Features
Collocation Probe Model:
A60-10N 60 Drawing 6 Excellent resolution
TF2C10N TF5C10N
A70-10N 70 Focal point diameter is very small
Note: Special type can be customized.
Ultrasound Probes www.cndoppler.com PAGE- 30

TRL Probe Custom and Special Probes


From the beginning of Doppler, it has always been our advantage to provide customers with custom and special probes
design, and leading the probe technique frontiers. To understand customers' demands and application requests, our
experienced application engineers, probe design experts work together with our customers, using the best way to provide perfect
Applications application solutions and product designs, to meet & satisfy the demands of challenging ultrasonic market.

Coarse grain weld detection


Attenuation material
Austenitic stainless steel weld

Performance Features
Excellent near surface resolution
Creeping Wave Probe For prop porcelain Micro Angle Beam Probe For inspect defects
Hollow Shaft Probe For train detection
Small scattering noise insulator,weld and bolt crack detection of engine blade root
Most of the probe interfaces are Lemo-00 connectors (top)

Echo Wave & Spectrum


A B C
Dimension
mm in mm in mm in
Drawing 1 48 1.9 45 1.8 37 1.5
Drawing 2 39.5 1.6 37 1.5 32 1.3
Drawing 3 32 1.3 30 1.2 27 1.1 1T3R Steel Plate Inspection Probe For Spot Weld Probe For Auto Short Welding
Aviation Special Probe For aviation detection
Drawing 4 0.9 0.9 22 0.9 Heavy Plates AUT Systems Detection
22.5 22
200 mV/Div 500n S/Div 3dB/Div 1MHz/Div

DA2C8×15LA60FS10

Specific Models & Parameters


Freq. a×b x 2 ß Focal Length (min ~ max)
Model Dimension
MHz in mm Steel in mm
DA2C20*34LA45FS50~120 2 0.79×0.13×2 20×34×2 45 2~4.7 50~120 Pen Type Probe Wall thickness detection Railroad Special Probe For rail detection
Special Dual Element Probe For coarse
for superficial pit base grain material detection
DA2C20*34LA60FS40~110 2 0.79×0.13×2 20×34×2 60 1.57~4.3 40~110 Drawing 1
DA2C20*34LA70FS40~100 2 0.79×0.13×2 20×34×2 70 1.57~3.93 40~100
DA2C15*25LA45FS30~75 2 0.6×1×2 15×25×2 45 1.18~3 30~75
DA2C15*25LA60FS25~70 2 0.6×1×2 15×25×2 60 1~2.76 25~70 Drawing 2

DA2C15*25LA70FS20~65 2 0.6×1×2 15×25×2 70 0.79~2.6 20~65


Blind Spot Short Pulse Probe Surface Wave Probe Guide Wave Probe High Temperature Probe
DA2C10*18LA45FS25~40 2 0.4×0.7×2 10×18×2 45 1~1.58 25~40
DA2C10*18LA60FS20~35 2 0.4×0.7×2 10×18×2 60 0.8~1.4 20~35 Drawing 3

DA2C10*18LA70FS20~35 2 0.4×0.7×2 10×18×2 70 0.8~1.4 20~35


Probe Cables
DA2C8*15LA45FS15~30 2 0.31×0.6×2 8×15×2 45 0.6~1.19 15~30 The probe cables can
according to customer needs any
DA2C8*15LA60FS15~25 2 0.31×0.6×2 8×15×2 60 0.6~1 15~25 Drawing 4
custom. Unless otherwise
DA2C8*15LA60FS15~25 2 0.31×0.6×2 8×15×2 70 0.6~1 15~25 specified, the length is generally BNC Q6 LEMO-01 C6 LEMO-00 Microdot
Note: Special type can be customized.
Scanners www.cndoppler.com PAGE- 32

PA+TOFD Scanner:FC-01 Bracelet Scanner: CRS-3

Doppler FC-01 Type PA+TOFD welds scanner is


suitable for pipe butt weld inspection with diameter over
6"(150mm) by axial direction, and flat butt weld
inspection. Combine with four probe clamps & one Features
wheel type encoder. Free collocation of PA probes &
TOFD probes by inspection needs. Can perform rapid detectionon small diameter pipe
weld both sides
Easy to assemble and use
Suitable for pipe butt welds inspection with diameter
between 46mm to 78mm
Other specifications can be customized
Parameter
Range Circumferential: φ6"(150mm)~Flat
Dimensions 426*110*125mm
Encoder Step 48Pulses/mm
IP Level Ip67
Operating Temperature -10℃~50℃

PA+TOFD Scanner: FC-02


PA/TOFD (FC02) Scanner support curvature adjustment, applicable to
detection for pipe and plate in direction of circumferential and axial.
Pressure regulator ensures wedge closely attach to work piece for an
effective detection. By equipped with reliable brake device, the scanner
can firmly stay at any position. By simple operation, most of scanning
Bracelet Scanner:CRS-1/CRS-2 Plate Butt Weld functions can be achieved manually. Scanner can be assembled with 4
probes according to detection requirement (PA / UT), convenient
assembly and disassembly.

Doppler CRS-1 / CRS-2 type Bracelet Scanner is suitable for pipe butt welds inspection with diameter between 0.8"(20mm) to Pipeline Ring Weld
Parameter
4.5"(114.3mm) Pipes by axial direction. Single, and Dual Chains are available for different inspection needs. Circumferential:φ6"(150mm)~Flat
Range
Axial:φ17"(425mm)~Flat
Dimensions 446*182*128mm
Parameter Encoder Step 48Pulses/mm
Range φ0.8"(20mm)~φ4.5"(114.3mm) Pipeline Radial Weld(Outside)
IP Level Ip67
Encoder Step 34Pulses/mm Operating Temperature -10℃~50℃
Width 55mm Clamp Width of Wedge 32~48mm
Height 13mm
IP Level Ip65
Operating Temperature -10℃~50℃

Pipeline Radial Weld (Inside) Brake Locking Device Features


Assembly of 4 probes, probe clamping arms can be disassembled
unilateral manually;
Two horizontal bars can be folded to adjust curvature, manual
Standard Kits adjustment can realize detection from 7 inch pipe to plate in direction
of axial ;
Two brackets (including angle adjusting block, handle and Two horizontal bars can be rotated, manually adjust a pair of probe
brake device); clamping arms can realize detection from 6 inch pipe to plate in
Two foldable horizontal bars with total length of 446mm; direction of circumference;
One encoder with 2.8m cable; Both sides have a brake device, scanner can stay at any position;
Four probe clamping arms; Inner water distribution device , save more space ;
One water distribution device; Space of walking wheel adjustable, freely work on short work piece;
Carrying case and other accessories. Clamp wedge for different size, strong adaptability.
Scanners www.cndoppler.com PAGE- 34

PA+TOFD Scanner: FC-02+ CCE-2 Single Probe Mini Scanner


Doppler CCE-2 Single Probe Type Mini Scanner is designed for recordable inspection of Pipe & Plate Welds by using a Single
Phased Array Probe.

Features
Compact Structure, Flexible & Easy Operation, and the probe
clamping is 90 ° direction adjustable, to perform lateral
scanning and vertical scanning.

Parameter
Parameter Parameter Scope of Application:
Circumferential:φ6"(150mm)~Flat Scope of Application: Same as FC-02 Circumferential Direction: From φ110mm to Plate Butt Welds
Range
Axial:φ17"(425mm)~Flat Standard Configuration: Added Four Variable Angle Probe Clamps. Longitudinal Direction: From φ180mm to Plate Butt Welds
Dimensions 446*182*128mm Scanner Size: 94*90*20mm
Encoder Step 48Pulses/mm Features Encoder Step: 38 Pulses/mm
IP Level Ip67 Features: FC-02+ Scanner is based on the model: FC-02, with extra Ingress Protection Ratting: Ip67
1~4 probe clamps, allows to clamp maximum 8 Phased Array or Wedge Clamping Width: 32~48mm
Operating Temperature -10℃~50℃
Clamp Width of Wedge 32~48mm TOFD probes, which is suitable for multi-groups of Phased Array or
TOFD inspection requirements.

MOS-02 Mouse Type TKY Conner Weld Scanner


Doppler MOS-02 Mouse Type Scanner is designed for recordable inspection of TKY conner welds by using Single Phased
Array Probe.
MOS-01 Mouse Type Girth Weld Scanner
Features
Doppler MOS-01 Mouse Type Scanner is designed for recordable inspection of circumferential above φ100mm Pipe Girth Flexible Transformation: Removal of TKY Web-Support-Rod will transform into MOS-01 Scanner.
Welds and Plate Butt Welds by using Phased Array Probe. Using Mouse Type Ergonomic Design, Smart and Comfort to Operate.
Other features are the same with MOS-01.

Parameter
Scope of Application: TKY Conner Welds; Circumferential
above φ100mm Pipe Girth Welds and Plate Butt Welds.
Scanner Size: 196*100*78mm
Encoder Step: 38 Pulses/mm
Ingress Protection Ratting: Ip67
Wedge Clamping Width: 32~48mm

Features
Using Mouse Type Ergonomic Design, Smart and Comfort to Operate.
Conceal Design of Encoder, more beneficial to prevent data loss of encoder track-slipping, and extend the lifetime of encoder. MOS-03 Mouse Type PA/TOFD Dual Probes Scanner
MOS-01 includes 4 strong magnetic wheels, combines pressure springs to make sure tightly closefit between Phased Array
probe and workpiece surface, and make sure sufficient coupling effects. Doppler MOS-03 Mouse Type Scanner is designed for bilateral simultaneous inspection of Plate Butt Welds by using Dual Phased
The probe clamping is 90 ° direction adjustable, to perform lateral scanning and vertical scanning. Array Probes, or single group of TOFD inspection.Equipped with a Laser Guide, to ensure when traveling along the weld center-
line during inspection.

Parameter Parameter
Scope of Application: Circumferential above φ100mm Pipe Girth Welds and Plate Butt Welds Scope of Application: Plate Butt Welds.
Scanner Size: 136*81.5*43mm Scanner Size: 350*182*43mm
Encoder Step: 38 Pulses/mm Encoder Step: 38 Pulses/mm
Ingress Protection Ratting: Ip67 Ingress Protection Ratting: Ip67
Wedge Clamping Width: 32~48mm Wedge Clamping Width: 32~48mm
Scanners 36
www.cndoppler.com PAGE-

MINI Scanner:DSC-01 GECKO Automated Crawler Scanner


Functional Characteristics
Phone WIFI + wired remote controller
360°real time monitoring camera
Support all orientation movements, with cruise control
Multi-probe clamp modes, welds compatible
Base material & corrosion inspections
Battery working up to 5 hours on-site

Application & Dimension

For Inspection of Large Pipes, Plates Base Material, Corrosion Inspection, with
Magnetic Wheels.
Can be fitted with 5L64-D3 Probe plus 0° wedge
Dimension : 153.8*93.0*86.6mm Application Filed
Tanks, big vessel
Plate butt welds
Base metal inspection

MINI Scanner:DSC-02 Spec of Crawler Scanner


Real time acquisition of working environment image, resolution 640*480
Camera steering can be controlled
Angle range in vertical direction: 20°~55°
Angle range in horizontal direction: 20°~140°
Displacement reciprocating precision error<=/-1mm
Speed accuracy error <5%
Static load force / motion >360N
Remote distance>40m(unobstructed)
Minimum tank diameter>5m
Minimum tank thickness>15mm
Speed range 23.14mm/s-129.37mm/s
Motion control mode of scan vehicle for central processor software:
Application & Dimension Free motion model;
Movement mode of shifting;
For Inspection of Large Pipes, Plates Base Material, Corrosion Inspection, with Magnetic Wheels.
Can be fitted with 5L64-D3 Probe plus 0° wedge. Velocity differential motion mode;
Dimension : 138.0*97.0*85.0mm Support video and movie playback;
Mobile terminal remote control software.
Automatic Systems www.cndoppler.com PAGE- 38

Multichannel Ultrasonic Inspection System POWERSCAN 256


System Brief Introduction Features

Multichannel Ultrasonic Inspection System is designed to use 4 channels as a module unit, and install any numbers of modules POWERSCAN256 system provides a platform for complex phased array inspection of nuclear power, aerospace,
into industrial framework according to user needs, then work with its integrated Ultrasonic NDT inspection system software. Can high-speed rail, and special equipments. It is optimized for inspections requiring 2 D matrix arrays probes , long
meet the widely needs of multiple ultrasonic automatic inspection and application of ultrasonic imaging. Reliable performance sound paths, low-frequency probes and complex geometries. Based on its wide band characteristics, it can drive
and easy maintenance. a wide range of probe frequencies, from 0.5 MHz up to 20MHz with a pulser voltage up to 220 Volts.

This system is based on Gigabit Ethernet data transmission, can achieve wire or wireless network configuration, reach up to 400 POWERSCAN2 5 6 is capable of handling data files up to 2 5 G B / s , especially suitable for complex automatic
channels transfer data simultaneously, no delay and no interference. Each channel has independent waveform display and data detection. Driven by a powerful software platform, it offers advanced data acquisition and analysis. Plus the real-
analysis, and with variable automatic functions, convenient to operate. time 3D environment makes the visualization of data analysis.A range of configurations are available to meet your
specific needs, from 64/64 up to 256/256PR.
Offering multiple 32bit encoder interface, I/O Signal Interface, connects with ECU or PLC to achieve automatic inspection.

And offering Secondary Development Library, suitable for institute & Academic research customizing purpose or research of
ultrasonic inspection of variable objects.

Performance
Gain 0.0 dB ~ 110.0 dB
Reject 0 % ~ 80 %
Velocity Max 9999 m/s
Range Achievable 3000 mm
PRF 200Hz, 500Hz, 1KHz, 2KHz
Delay 0.01μs ~ 100.00μs
Pulse Energy 50V, 100V, 200V, 300V
Rectification Full Wave, Positive Half Wave, Negative Half Wave, RF
Bandwidth Select 2MHz ~ 8MHz, 0.5MHz ~ 20MHz
Pulse Width 50ns ~ 1000ns
Transceiver Mode Pulse-Echo, Pitch-Catch
Pulse Dumping 500Ω, 50Ω
Average Count Selectable 1, 2, 4, 8, 16 times
Performance
Relevant Count Selectable 1 ~ 5 time Features Specifications
Receiver/Pulser 256/256PR independent hardware transmission
Imaging Codec Area Spread Spectrum Imaging
Pulser Voltage 50V/100V/220V
Pulser Method negative square wave / multi – pulse coding
Pulser Width 30-1000ns
TCG Range 40dB
Receive Delay 0-20μs/2.5ns
Total gain 0-100dB
Bandwidth 0.5-25MHz
Digital frequency 50-400MHz automatic adjustment, 12bit ADC
Function Features Focusing single point focus / customized focusing / surface fitting
Scan type linear, Sectorial, 3D real time imaging
Can configure any multiple channel simultaneously real-time waveform display, or zoom in assigned channel.
Can achieve whole range automatic inspection, automatic inspection data saving according to input, output signals. No. of Focal Law 8192

Inspection data can be playback at any time, precise defects positioning. Adaptive filtering Yes
Local save parameter configurations, one key to access calibrated parameter. Band filter whole data real-time average of 40 steps
Distant data display of Defects Gate, Back Wave Gate, Interface Wave Gate, and Tracking Gate.
User-defined Interface Style
User-defined Test Reports, and print directly.

You might also like