7030
7030
7030
: 104780-7030
조 정 데 이 터 ENG. Type : T-2 H/All A/T
INJ. PUMP CALIBRATION DATA A kind of car : Grace
Drawing No. : 97 - 01 - 09 - 04 Company : HYUNDAI MOTORS
General Ass'y No. : KP-VE4/10F2100RNP.... Date : 1997. 01. 09.
Pre - Stroke : Pump rotation:Clockwise-viewed from drive side
1. Test Conditions
1-1 Nozzle ; 105780-0000(KP-DN12SD12T) 1-4 Injection pipe : 2mm×6mm×840mm
1-2 Nozzle holder : 105780-2080 1-5 Fuel oil temperature : 45 + 5℃
1-3 Nozzle opening pressure : 150+
150+5 Kgf/
Kgf/㎠ 1-6 Supply pump pressure : 0.2 Kgf/
Kgf/㎠
2. Setting Pump speed Settings Charge air Difference
(r/min) pressure(mmHg) in delivery
2-1 Timing device travel 1,100 3.2±0.2 mm
2-2 Supply pump pressure 1,100 4.
4.7±0.3 Kgf/
Kgf/㎠
2-3 Full load delivery(FULL) 1,100 50.1±1.0 cc/1000st 3.0
※ Potentiometer adjustment
Pump speed Control lever Fuel injection In-put Out-put Remark
(r/min) position Q'ty(cc/1000st) voltage voltage
- Idling - 10V 1.3±0.3 V Adjusting point
- Full speed - 10V (6.0±0.6) V Check point
In-put Line(+10V)
Out-put Line
Ground Line
Ass'y No. : 104780 - 7020, 7030, 7040, 7050