GENERAL NOTES
1. ALL DIMENSIONS ARE IN MILLIMETERS UNLESS 8. IN TWO WAY SLAB THE REINFORCEMENT ALONG
OTHERWISE SPECIFIED. DRAWING SHALL NOT BE THE SHORTER SPAN SHALL BE AT LOWER LEVEL
SCALED-OUT. ONLY WRITTEN DIMENSION SHALL BE UNLESS OTHERWISE SPECIFIED.
FOLLOWED. G
MENTIONED BELOW:
11. THE SAFE BEARING CAPACITY OF THE SOIL HAS
a. M25 GRADE FOR ALL RCC WORKS. BEEN TAKEN AS 180 kN / Sq.m AT 1.50 m BELOW THE
EXISTING GROUND LEVEL, AS INFORMED BY THE
5. CLEAR COVER FOR MAIN REINFORCEMENT EE/ CED 3 VIDE EMAIL DATED 31.08.2018. D
SHALL BE:
a. FOOTINGS = 50mm
b. COLUMNS = 40mm
c. BEAMS = 30mm 12. THE STRUCTURE HAS BEEN DESIGNED FOR
d. SLABS = 20mm STILT + 2 STOREYS ONLY .
C
7. THE WATER USED FOR ALL CONCRETE WORKS ENGINEERING PROJECT MANAGEMENT CONSULTANCY AND RESEARCH PVT. LTD. B
AN IIT- MADRAS INCUBATED COMPANY
SHALL CONFORM TO CLAUSE 5.4 OF I.S456-2000. CREATING VALUES FOR YOUR INVESTMENT
CLIENT : CONSULTANT :
PROJECT :
ARCHITECT :
SUPPLIER / CONTRACTOR :
JOB No. :
TITLE :
DRG. No.
1 2 3 4 5 6 7 8 9 10 11 12