YL 007M2BX User - Manual PDF
YL 007M2BX User - Manual PDF
YL 007M2BX User - Manual PDF
System disarmed
11/26/2013
User’s Manual
Profile
For a better understanding of this product, please read this user
manual thoroughly before using it.
CONTENTS
Chapter 1. Features 1
Chapter 2. Control Panel Introduction 2
Chapter 3. Initialization 4
Chapter 4. System Settings 4
1. Enter Settings 4
2. Add Remote Controls 5
3. Delete Remote Controls 5
4. Pair Wireless Sensors 6
5. Delete Wireless Sensors 7
6. Defense Zone Place Setting 7
7. Defense Zone Mode Setting 8
8. Siren Ring Time Setting 9
9. Alarm Delay Setting 9
10. Alarm Number Setting 10
11. Delete Alarm Number 11
12. SMS Number Setting 11
13. Delete SMS Number 12
14. Voice Recording 12
15. Record Play 13
16. System Date Setting 13
17. System Time Setting 14
18. Timely Arm Setting 14
19. Timely Disarm Setting 15
20. Wireless Siren Setting 16
21. Wireless Siren Encryption 17
22. Change Operate Password 18
23. Change Program Password 19
24. Arm Delay Time Setting 20
25. Alarm Delay Time Setting 20
26. Voice Prompt Function 21
27. Siren Prompt for Arm/Disarm 21
28. Backlight Setting 22
29. Siren Setting in SOS Mode 23
30. SMS Reply for Arm/ Disarm 24
31. SMS Alert for External Power Failure/ Recovery 25
32. Language Setting 25
33. Factory Reset 26
34. Forget Password 26
Chapter 5. Operation Instructions 26
1. Away arm 26
2. Home Arm 27
3. Disarm 28
4. Answer Alarm Call 29
5. Remote Control 29
6. Emergency Help 30
7. System Dialing Function 30
8. Alarming Record Checking 30
Chapter 6. Technical Parameters 31
Chapter 7. Components List 32
Chapter 8. Care and Maintenance 33
Features
Chapter 1. Features
Elegant and advanced touch keypad for easy operation;
128x64 lattice LCD screen with clock display;
4 wired and 10 wireless defense zones; each wireless zone supports
maximum 10 sensors;
Support maximum 8 remote controls;
One relay switch: it will be connected when alarming;
Built-in high-volume speaker, and artificial intelligent digital voice
announcer;
Built-in artificial intelligent English message;
10-second automatic voice message recording;
Can preset 6 phone numbers: when alarming, system will make audio
call to these numbers automatically;
Can preset 3 SMS numbers: when alarming, system will send SMS;
Timely arm and disarm;
Can be used as a wireless telephone by using keypad to make calls;
One-key-control: out arm, home arm, arm by remote controller or
phone call;
SOS, fire, gas, door, hall, window, balcony, and boundary places
alarm;
Real-time, delay, 24 hours, bypass defense zones programming
function;
Wireless learning code: easy to add additional wireless accessories;
Remote control the device to arm, disarm, monitor, and intercom by
phone;
Record checking: the device can store 30 alarm records;
Different arm status: out arm, home arm, delay arm and timely arm;
Arm by different ways: panel keypad, remote controller, remote call;
Alarm call has the priority: even when the number of the device is busy;
Built-in LI battery: automatically recharge.
1
Control Panel Introduction
3
1 System disarmed
11/26/2013
2 M
2
Control Panel Introduction
press this button. Pressing it during the phone call will hang up the call.
SOS: emergency alarm
ESC: clear the input content or back to last operation
ENTER: confirm
POWER IN
OFF ON
10
11
12
1
2
3
4
5
6
7
8
9
SIREN+
SIREN-
T-GND
JDQ-1
JDQ-2
Zone1
Zone2
Zone3
Zone4
T-Vcc
GND
GND
SIREN+
SIREN-
T-GND
Zone 2
Zone 3
Zone 4
JDQ-1
JDQ-2
Zone l
T-Vcc
GND
GND
RED BLACK
The alarm SMS for wire zone: 1/2/3/4 Wired zone SOS Alarm
5. Power switch. (Note: you should turn on this switch even you have
connected the power adaptor.)
3
Initialization
6. SIM card slot: Please pay attention to the direction arrow marked
on the slot: “LOCK” “OPEN”. Do not insert or take
out the SIM card when the main unit is power on.
Chapter 3. Initialization
Correct initiation of the main panel is important to its normal working
and lifespan.
1. Connect the wired accessories that you need.
2. Insert SIM card.
3. Turn on the power switch.
4. Connect the power adaptor. The main panel will start self-inspection
and the POWER indicator LED will turn on. If this LED does not
light on, you need to restart the panel. Please do it at least 10
seconds later as repeated power on and off in short time is bad to
the panel's service life.
5. The signal icon and SIM card icon on the LCD screen will flash when
searching signal. And the SIM card icon will disappear after
searching GSM network successfully.
6. Check the GSM signal icon on the screen. Normal performance will
be affected when the signal has less than 3 bars. Please put the
main panel at the place with good GSM signal.
4
System Settings
Fig 1: disarm status Fig 2: please enter password Fig 3: press ENTER to set
Remote control
System disarmed System disarmed
Enter:
11:49 11/26/2013
123123 Exit Enter
Operation figures:
Fig 1: enter remote control menu Fig 2: choose remote control serial Fig 3: waiting to receive signal
number and pair menu
Fig 4A: recognize successfully Fig 4B: the remote control has Fig 5: press ENTER to save
been paired before
5
System Settings
6
System Settings
Fig 1: enter defense zone setting Fig 2: choose zone number and Fig 3: waiting signal from sensor
press ENTER
Fig 4A: recognize successfully Fig 4B: the host has the same Fig 5: press ENTER to save
code with sensor code
Zone 1 Zone 1
241015162 Error
Save completed
Normal code Repeat code
Zone Zone 1
Pair
Delete completed
Delete
7
System Settings
Operation figures:
Fig 1: enter defense zone setting Fig 2: choose defense zone place Fig 3: press ENTER to confirm
The format of alarm SMS: [1~10] wireless zone [place] alarm. For
example, you set the place of zone 4 as “window”. The alarm SMS you
receive is: 4 wireless zone window alarm.
Method: enter defense zone setting menu, press “2” or “8” to choose
HOME arm status (enable or disable), press ENTER to confirm.
Setting methods for OUT arm and DISARM are the same.
Operation figures:
8
System Settings
Fig 1: enter defense zone setting Fig 2: choose mode Fig 3: press ENTER to confirm
1
9
System Settings
Operation figures:
Fig 1: enter defense zone setting Fig 2: choose delay status Fig 3: press ENTER to confirm
Exit
Exit Enter
Enter Back
Back Enter
Enter Back Enter
Phone 1 Phone 1
123456789
Save completed
Delete
Back Enter
10
System Settings
Operation figures:
Fig 1: enter phone number setting Fig 2: choose the number you Fig 3: choose “delete”
menu want to delete
Delete completed
11
System Settings
Save completed
Delete completed
12
System Settings
Operation figures:
Fig 1: enter record setting Fig 2: start recording Fig 3: record for 10 seconds
Recording
05
Exit Enter
13
System Settings
Operation figures:
Fig 1: enter time setting menu Fig 2: choose date setting menu Fig 3: input the date
Date
Save completed
Time
Back Save
14
System Settings
Save completed
15
System Settings
Operation figures:
Fig 1: enter time setting menu Fig 2: you'll see date setting menu Fig 3: press “6” to choose
“timely disarm”
Save completed
16
System Settings
Operation figures:
Fig 1: enter wireless control Fig 2: control menu Fig 3: press “6” to choose
menu wireless siren
Save completed
17
System Settings
Operation figures:
Fig 1: enter settings menu Fig 2: enter operate password Fig 3: input the 6-digit password
menu
Fig 4: save it
Save completed
18
System Settings
Save completed
Delay arm
08
Please input
Back Save
19
System Settings
Delay alarm
15
Please input
Back Save
20
System Settings
Voice prompt
Disable
Back
Exit Enter
Siren prompt
Enable
Enable
Exit Enter
21
System Settings
The backlight of the LCD screen and keypad will be off automatically
after a certain period of time when there is no operation on the keys.
Users can set it keep on if required. System default is disable.
Method: enter “settings” menu, and then you'll see “operate password”.
Press “6” to choose “backlight on” and choose “enable” or “disable”.
Operation figures:
Fig 1: enter settings menu Fig 2: you'll see operate Fig 3: press “6” to choose
password menu “backlight on”
Backlight on
Enable
Enable
Exit Enter
22
System Settings
Fig 1: enter settings menu Fig 2: you'll see operate Fig 3: press “6” to choose
password menu “remote siren”
Remote siren
Enable
Disable
Exit Enter
23
System Settings
Exit
Back Enter
Enter
You can also use your mobile phone to send SMS “123456#61#” to the
panel to check the system status. Then you can also receive the above
SMS.
Exit Enter
24
System Settings
language
English
Exit Enter
25
System Settings
Fig 1: enter settings menu Fig 2: you'll see operate Fig3: press “6” to choose
password menu “factory setting”
Please wait
Return to default
setting
Operation figures:
Fig 1: under disarm status Fog 2: input 95175308246 Fig 3: confirm the operation
26
Operation Instructions
System armed
11:49 11/26/2013
2. Home Arm
Home arm means part of the defense zones are in arm status. When
there's someone at home, it is recommended, for safety purpose, to
enable some of the detectors (such as sensors for door, window,
balcony, etc), and disable the others (such as sensors for the hall or
some places easy to be triggered by person at home).
Use main panel keypad to press [STAY]. The screen will display
“system armed”.
Remote control operation: press home arm button [ ] on the remote
control.
Main panel operation: press [STAY].
27
Operation Instructions
Home arm
11:49 11/26/2013
3. Disarm
The purpose of disarming the system is to let it not in alert status. One
way is normal disarming after operation of arming, and the other is to
stop the main unit alarming. After the operation of disarm, all the
defense zones except 24-hour zone shall not work.
Use main panel keypad to input operate password + ENTER. The
screen will display “system disarmed”.
Remote controller operation: press disarm button [ ] on the remote
controller.
Main panel operation: password+ENTER
System Disarmed
11:49 11/26/2013
28
Operation Instructions
5. Remote Control
Dial the number associated to the alarm main unit by phone (mobile
phone), and after the ringing cycle, you can hear a voice prompt
“Please enter password”. If the password is right, you will here “Press 1
to arm, Press 2 to disarm, Press 3 to Monitor, Press 4 to Intercom”. If
the password is wrong, you will hear a prompt voice “wrong password,
please re-enter”. System default password is 1234.
Press [1]: arm, if finished successfully, you will hear a voice prompt
“System armed”.
Press [2]: disarm, if finished successfully, you will hear a voice prompt
“System disarmed”.
Press [3]: monitoring for 30 seconds, to continue monitoring, press [3]
again to monitor for another 30 seconds.
29
Operation Instructions
Press [4]: two-way intercom for 30 seconds. You can't operate the main
unit during this time.
6. Emergency Help
Sometimes, an accident may happen, e.g. a senior person or child
suddenly becoming ill or being in great pain, a fire emergency, burglar
intrusion. Press [SOS] button on keypad, or [SOS] button on remote
controller or wireless panic button, the main unit will alarm and make
call to the preset user numbers.
Remote control operation: press [SOS] button on the remote control.
Alarm SMS: X remote control SOS alarm (X: the remote control serial
number 1~8).
Main panel operation: press [SOS].
Alarm SMS: SOS alarm!
7. System Dialing Function
During disarm status, you can use the main unit to make any call just
like using a land-line telephone. Dial telephone number on keypad,
press [CALL] button, the main unit will make a beep and the LCD
screen will display the number you are calling. After the call, press
[CALL] button again, the call will be hanged up and main unit will be in
disarm status.
8. Alarming Record Checking
This alarm system can store 30 alarm records. When the record
number exceeds 30, the most previous record will be deleted
automatically.
The icon [ ] will keep flashing if there's alarm record not been
checked.
Checking method: In disarm state, input [ESC] button on the panel,
you can check the alarm record. Press “4” or “6” to upturn or downturn,
and press “ESC” to exit checking. If there's not alarm record, it will
display “No alarm record”.
30
Technical Parameters
Operation figures:
Fig 1: press ESC in disarm Fig 2: press 4 or 6 to check Fig 3: press 4 or 6 to check
status
31
Components List
List 2
Emergency
Zone 7-10button effective invalid invalid 7/8/9/10 wireless zone
SOS alarm
Wired defense effective invalid invalid 1/2/3/4 wired zone
zone (7-10) SOS alarm
SOS button on effective invalid effective SOS alarm
the panel
Remote control effective effective effective X remote control SOS
SOS button alarm (X: 1~8)
Program Password 123123 Operate 123456
Password
Wireless
Siren Ring Time 1min Enable
Control
Arm Delay 40s Alarm 60s
Delay
32
Care and Maintenance
33
Care and Maintenance
Please read the suggestions above carefully and follow the instructions
herein. If any of the equipment does not work properly, please send it
to the dealer or authorized service point for repair. We will try our best
to solve the problem for you as soon as possible.
34
The following sensors are optional:
35
MOBILE CALL
3 12 1 -EN
GSM Alarm System