IP Intelligent System Controller: CAT-6A
IP Intelligent System Controller: CAT-6A
IP Intelligent System Controller: CAT-6A
DEACTIVATE/DEFEAT THE DOOR LOCKS ALONG EGRESS ROUTE. INTERFACE UNIT AND SUPPORTING D8.0-10/1 C1A X 1 1 1 1
D8.0-13/1 C1A X 1 1 1 1
TR9.1 IDF 9.1-18 CABLING SHALL BE INSTALLED BY FIRE ALARM SYSTEM INSTALLER
D8.0-14/1 C1A X 1 1 1 1
FIRST LEVEL D8.0-15/2 C1A X 1 1 1 1 X
D8.0-16/1 C1A X 1 1 1 1
D8.0-17/1 C1A X 1 1 1 1 X
RS-485 MULTIDROP 22/4 COND. SHEILDED D8.0-19/1 C2C X 2 1 1 1 X INTERCOM INTEGRATION
D8.0-27/1 C1A X 1 1 1 1
D8.0-28/1 C1A X 1 1 1 1
CONTACT CLOSURE - 22/2 COND. INTERCOM
C1A C1A C1A C1A C1A C1A C1A C1A C1A C1A C2B C2B D8.0-29/2 C1A X 1 1 1 1 X
CONTROL
D8.0-34/1 C1A X 1 1 1 1
D9.0-13/1 D9.0-12/1 D9.0-11/1 D9.0-10/1 D9.0-21/1 D9.0-07/1 D9.0-06/1 D9.0-05/1 D9.0-04/1 D9.0-02/1 D9.0-24/1 D9.0-24/2 COORDINATE WITH GENERAL CONTRACTOR AND GATE
PED GATE 1 CP X 1 1 1 1 X
CONTRACTOR
RS-485 MULTIDROP 22/4 COND. SHEILDED COORDINATE WITH GENERAL CONTRACTOR AND GATE
PED GATE 2 CP X 1 1 1 1 X
CONTRACTOR
COORDINATE WITH GENERAL CONTRACTOR AND GATE
PED GATE 3 CP X 1 1 1 1 X
CONTRACTOR
C2B C1A C1A C1A C1A C1A C1A C1A C1A
COORDINATE WITH GENERAL CONTRACTOR AND GATE
PED GATE 4 CP X 1 1 1 1 X
INTELLIGENT D9.0-15/2 D9.0-16/1 D9.0-17/1 D9.0-18/1 D9.0-19/1 D9.0-20/1 D9.0-23/1 D9.0-08/1 D9.0-09/1 CONTRACTOR
D9.0-02/1 C1A X 1 1 1 1
D9.0-04/1 C1A X 1 1 1 1
D9.0-05/1 C1A X 1 1 1 1
D9.0-06/1 C1A X 1 1 1 1
D9.0-07/1 C1A X 1 1 1 1
C1A C1A C1A C1A C1A C1A C1A C1A D9.0-15/2 C2B X 2 1 1 1 X
D9.0-16/1 C1A X 1 1 1 1
D8.1-21/1 D8.1-18/1 D8.1-17/1 D8.1-16/1 D8.1-13/1 D8.1-12/1 D8.1-11/1 D8.1-10/1 D9.0-17/1 C1A X 1 1 1 1
D9.0-18/1 C1A X 1 1 1 1
INTELLIGENT RS-485 MULTIDROP 22/4 COND. SHEILDED D9.0-19/1 C1A X 1 1 1 1
IP SYSTEM D9.0-20/1 C1A X 1 1 1 1
CAT-6A D9.0-23/1 C1A X 1 1 1 1
CONTROLLER C1A C1A C1A C1A C1A C1A C1A C1A C1A C1A C1A C1A C1A D9.0-24/1 C2B X 2 1 1 1 1 X
D9.0-24/2 C2B X 2 1 1 1 1 X INTERCOM INTEGRATION
D8.1-20/1 D8.1-29/1 D8.1-30/1 D8.1-36/1 D8.1-01/1 D8.1-02/1 D8.1-03/1 D8.1-04/1 D8.1-05/1 D8.1-06/1 D8.1-07/1 D8.1-08/1 D8.1-09/1 D9.0-39/1 C1A X 1 1 1 1
INTERCOM INTEGRATION - COORDINATE WITH GENERAL
VEHICLE GATE CV 1 1
CONTRACTOR AND GATE CONTRACTOR
D9.1-01/1 C1A X 1 1 1 1
NOTE: DOOR POWER SUPPLIES SHALL INTERFACE WITH SIGNAL FROM FIRE ALARM SYSTEM TO D9.1-03/1 C1A X 1 1 1 1
TR8.1 IDF 8.1-21 DEACTIVATE/DEFEAT THE DOOR LOCKS ALONG EGRESS ROUTE. INTERFACE UNIT AND SUPPORTING D9.1-04/1 C1A X 1 1 1 1
CABLING SHALL BE INSTALLED BY FIRE ALARM SYSTEM INSTALLER FIRST LEVEL D9.1-05/1 C1A X 1 1 1 1
D9.1-06/1 C1A X 1 1 1 1
D9.1-07/1 C1A X 1 1 1 1
D9.1-08/1 C1A X 1 1 1 1
RS-485 MULTIDROP 22/4 COND. SHEILDED
D9.1-09/1 C1A X 1 1 1 1
D9.1-10/1 C1A X 1 1 1 1
C1A C1A C1A C1A C1A C1A C1A C1A C1A D9.1-11/1 C1A X 1 1 1 1
D9.1-12/1 C1A X 1 1 1 1
D8.0-17/1 D8.0-15/2 D8.0-14/1 D8.0-13/1 D8.0-10/1 D8.0-09/1 D8.0-08/1 D8.0-07/1 D8.0-06/1 D9.1-15/1 C1A X 1 1 1 1
D9.1-16/1 C1A X 1 1 1 1
RS-485 MULTIDROP 22/4 COND. SHEILDED D9.1-17/1 C1A X 1 1 1 1
D9.1-18/1 C1A X 1 1 1 1
D9.1-23/1 C1A X 1 1 1 1
C2C C1A C1A C1A C1A C1A C1A C1A C1A C1A C1A C1A D9.1-24/1 C1A X 1 1 1 1
INTELLIGENT D8.0-19/1 D8.0-34/1 D8.0-16/1 D8.0-27/1 D8.0-28/1 D8.0-29/2 D8.0-01/1 D8.0-02/1 D8.0-03/2 D8.0-03/1 D8.0-04/1 D8.0-05/1
D9.1-25/1 C1A X 1 1 1 1
D9.1-27/1 C1A X 1 1 1 1
IP SYSTEM D9.1-28/1 C1A X 1 1 1 1
CONTACT CLOSURE - 22/2 COND. INTERCOM
CAT-6A CONTROLLER CONTROL
D9.1-29/1 C1A X 1 1 1 1
RS-485 MULTIDROP 22/4 COND. SHEILDED D9.1-31/1 C1A X 1 1 1 1
D9.1-33/1 C1A X 1 1 1 1
D9.1-34/1 C1A X 1 1 1 1
CP CP CP CP GENERAL NOTES:
A REFERENCE ARCHITECTURAL DRAWINGS QFD033-HAL-DWG-01-0932 TO 0935 AND IRONMONGERY SCHEDULE (DOCUMENT NUMBER: QFD033-HAL-SC-01-0001) FOR FURTHER INFORMATION.
PEDESTRIAN PEDESTRIAN PEDESTRIAN PEDESTRIAN B NUMBERS DEPICTED WITHIN THIS SCHEDULE DENOTE QUANTITY OF DEVICES. THE SECURITY CONTRACTOR SHALL INSTALL AND PROVIDE CONNECTIVITY TO DOOR HARDWARE DEVICES (INCLUDING
GATE #1 GATE #2 GATE #3 GATE #4 AUTOMATIC DOOR OPENERS) FOR INTEGRATION INTO THE ACCESS CONTROL SYSTEM.
C REFERENCE SECURITY DOOR DETAILS FOR CONDUIT AND BOX REQUIREMENTS. IF DOOR REQUIREMENTS ARE IN CONFLICT, PROVIDE MOST STRINGENT REQUIREMENTS TO MEET ALL POSSIBLE
CONFIGURATIONS.
NOTE: DOOR POWER SUPPLIES SHALL INTERFACE WITH SIGNAL FROM FIRE ALARM SYSTEM TO D POWER SUPPLIES FOR DOOR HARDWARE ARE INTENDED TO BE DISTRIBUTED FOR MULTIPLE DOORS. QUANTITIES INDICATED IN THIS SCHEDULE DO NOT REFLECT TOTAL NUMBER OF POWER SUPPLIES
DEACTIVATE/DEFEAT THE DOOR LOCKS ALONG EGRESS ROUTE. INTERFACE UNIT AND SUPPORTING REQUIRED. THE SECURITY CONTRACTOR SHALL PROVIDE AND DISTRIBUTE ADEQUATE DOOR POWER PER MANUFACTURER REQUIREMENTS.
TR8.0 MDF #1 8.0-17 CABLING SHALL BE INSTALLED BY FIRE ALARM SYSTEM INSTALLER E FIRE ALARM INTEGRATION: IN THE EVENT OF FIRE ALARM, THE FIRE ALARM SYSTEM SHALL OVERRIDE SELECT FEATURES OF SPECIFIED DOORS. FIRE ALARM EVENT SHALL INCLUDE BUT NOT BE LIMITED TO:
Halcrow (Consulting Engineers and Architects) Ltd.
GROUND LEVEL RELEASE OF FAIL SECURE (FS) LOCKING DEVICES AND RELEASE OF HOLD OPEN DEVICES. COORDINATE FIRE ALARM REQUIREMENTS WITH FIRE ALARM CONTRACTOR PRIOR TO INSTALLATION.
A CH2M HILL COMPANY