Unit 3
Unit 3
Unit 3
3. The rate of drop in frequency of control inlet valve due to an increase in generation of power (dPG) on prime
mover is called
A. speed regulation B. speed efficiency C. governer operation D. none of the above
4.in which control the input to the turbine and are actuated by the speed control mechanism?
A. Speed control mechanism B. Speed changer C. Governor controlled valves D.Speed governor
UNIT 4
4. What is the condition for uncontrolled case in a two area system
A. ΔPc1=0 B. ΔPc2=0 C. ΔPc1=ΔPc2=0 D. none of the above
5. Two alternators are running in parallel. If the field of one of the alternator is adjusted it will
A. reduces its speed B. change its load C. change its p.f. D. change its frequency
6. The synchronizing coefficient between two areas of a two area power system is
A. A B. B C. C D. D
7. Frequency of the resonant vibrations lies in the range of
A. 50-100 Hz B. 10-20 Hz C. 100-200 Hz D. none of the above
10. The system frequency must be maintained is requirement for successful for operation of the system is
A.Figid limits. B.Within narrow C.Within narrow and rigid limits. D.49.9 Hz
UNIT 5
1. Shunt capacitance is usually neglected in the analysis of
A. short transmission lines B. medium transmission lines C. long transmission lines D. medium + long lines
2. For the same voltage boost, reactive power capacity is more for a
A. shunt capacitor B. series capacitor C. same for both D. none of the above
3. If a line is considered with negligible power losses, then the real power transmitted will be proportional to
______ and the reactive power drop is proportional to ____
a) sinδ, voltage drop across line
b) cosδ, voltage drop across line
c) δ, voltage drop across line
d) voltage drop across line, sinδ
5. If a line is considered with negligible power losses, then the real power transmitted will be proportional to
___________
a) sinδ
b) cosδ
c) δ
d) sin2δ
View Answer
6. If a line is considered with negligible power losses, then the reactive power transmitted is proportional to
receiving end voltage.
a) True
b) False
7. Choose the most feasible method for raising the power to be delivered at the reactive end.
(i)Reducing the line reactance
(ii)Raising the voltage level
a) (i)
b) (ii)
c) (i), (ii)
d) None of the methods
8. The lagging reactive power delivered by a line is proportional to the line _____ and independent of _____
a) voltage,δ
b) δ, voltage
c) voltage, sinδ
d) voltage drop, cos δ
A. Series reactors
B. Shunt capacitors
C. Series capacitors
D. Shunt reactors
1. For a good voltage profile under no-load condition, a long line needs _________________ at receiving end.
2. For a small KVAR requirements ____________________ is more economical.
3. The series compensation increase ______________________.
4. For a lumped inductive load with increase in supply frequency, P ________________ and Q
____________________.
5. the power balance equation is_____________________(interm of PG, PL, PD )
6. For stability and economical reasons, we operate the transmission lines with power angle in the range
______________________.
7. Series Controllers provide independent__________ compensation
8. Shunt reactors are used for ________power factor circuits
9. overvoltage may cause___________failure ( voltage/current/insulation/frequency)
10. fully loaded line __________reactive power (generates/absorbs)