RS-232/RS-485 CONVERTER: Users Manual Revision 2

Download as pdf or txt
Download as pdf or txt
You are on page 1of 7

RS-232/RS-485 CONVERTER

USERS MANUAL
REVISION 2

06/11/1989

COPYRIGHT © 1989 MIILLE APPLIED RESEARCH CO., INC.

Proprietary rights of MIILLE APPLIED RESEARCH CO., INC. are involved in this subject matter
and all manufacturing, reproduction, use and sales rights pertaining to such subject matter are
expressly reserved. It is submitted in confidence for a specified purpose and the recipient, by
accepting this material, agrees that this material will not be used, copied or reproduced in whole
or in part, nor its contents revealed in any manner or to any person except to meet the purpose
for which it was delivered.

CUSTOM ENGINEERED DESIGNS


RS232/485 CONVERTER i
TABLE OF CONTENTS

TABLE OF CONTENTS

1 GENERAL INFORMATION ..................................................................... 1


1.1 INTRODUCTION ..................................................................... 1
1.2 GENERAL DESCRIPTION ...................................................... 1
2 INSTALLATION AND OPERATION ........................................................ 2
2.1 INTRODUCTION ..................................................................... 2
2.2 SERIAL INTERFACE OPTION SELECTION .......................... 2
2.2.1 BAUD RATE SELECTION....................................... 2
2.2.2 NUMBER OF DATA BITS SELECTION ................. 3
2.2.3 STOP BIT SELECTION........................................... 3
2.2.4 PARITY SELECTION .............................................. 3
2.3 SERIAL INTERFACE CONNECTIONS................................... 4
2.4 POWER CONNECTION .......................................................... 4
2.5 PANEL MOUNTING LOCATIONS .......................................... 4
3 SPECIFICATIONS ................................................................................... 5
3.1 INTRODUCTION ..................................................................... 5
3.2 RS-232/RS485 CONVERTER SPECIFICATIONS.................. 5

LIST OF FIGURES
Figure 2.1 Mounting Panel Hole Locations ................................................ 5

LIST OF TABLES
Table 2.1 Baud Rate Selection................................................................... 2
Table 2.2 Number of Data Bits Selection................................................... 3
Table 2.3 Parity Selection........................................................................... 4
Table 2.4 Serial Interface Connections ...................................................... 4

APPENDIX
PARTS LIST RS-232/RS-485 CONVERTER
ASSY. DRAWING RS-232/RS-485 CONVERTER
SCHEMATIC RS-232/RS-485 CONVERTER

COPYRIGHT © 1989 MIILLE APPLIED RESEARCH CO., INC. i


HOUSTON, TEXAS
RS232/485 CONVERTER 1
GENERAL INFORMATION

GENERAL INFORMATION

1.1 INTRODUCTION
This Users Manual provides the information necessary for installation, maintenance and
operation of the MARC RS-232 to RS-485 converter module. This module is identified as Part
Number MP122-002.

1.2 GENERAL DESCRIPTION


The MARC MP122-002 converter provides a convenient method of interfacing RS-232
based equipment with an RS-485 network using a half duplex, single twisted pair transmission
line. Up to thirty two (32) RS-485 users can be connected together at rates up to 9600 baud and
separations of up to 6000 feet. The MP122-002 is a small (3.85" X 3.00") printed circuit module
designed for panel mounting. The board includes a power supply, an RS-485 Transceiver,
RS-232 Driver/Receivers, a Single Character Buffer and Terminal Strips for wiring termination.
Only Transmit, Receive and Ground signal lines are used on the RS-232 side of the converter to
allow its use in many different applications. Data Terminal Ready (DTR), Request to Send
(RTS), Carrier Detect (CD) and Clear to Send (CTS) interface signals are not required for
operation of the converter. Operation in an RS-485 environment requires that all devices have
some level of intelligence in order to establish an orderly flow of data on the single twisted pair.
The MP122-002 can be used to connect devices with RS-232 interfaces into almost any type of
RS-485 network as long as the devices have the requisite level of intelligence. The RS-485
transceiver is normally in the ’receive’ mode. Any data on the RS-485 bus is converted to RS-
232 voltage levels and immediatly transmitted out the RS-232 side of the converter to the
RS-232 device. When the RS-232 device determines that it can transmit data onto the bus it
sends a character to the converter board. The converter board buffers the incoming serial data
until a complete character has been received. After a complete character has been received the
converter board will switch its RS-485 transceiver to the ’transmit’ mode and send the character
onto the RS-485 bus. The converter can receive the next character from the RS-232 device at
the same time that it is sending the first character onto the RS-485 bus.

COPYRIGHT © 1989 MIILLE APPLIED RESEARCH CO., INC. 1


HOUSTON, TEXAS
RS232/485 CONVERTER 2
INSTALLATION AND OPERATION

INSTALLATION AND OPERATION

2.1 INTRODUCTION
This section details the information necessary for set-up and operation of the
RS-232/RS-485 converter.

2.2 SERIAL INTERFACE OPTION SELECTION


Since the converter board must temporarily buffer an incoming character from the
RS-232 side the board must have its serial interface receiver set up to match the transmitted
serial data. The set-up parameters include the baud rate, number of data bits, number of stop
bits and parity. Switch S1, a nine position DIP switch is used to select the serial interface
parameters as detailed in the following sections.

2.2.1 BAUD RATE SELECTION

The baud rate is selected using switch positions 5 thru 8 on switch S1. The switch
should be set as shown in Table 2.1 below.

SWITCH BAUD RATE


8765
0000 110
0001 150
0010 300
0011 2400
0100 1200
0101 1800
0110 4800
0111 9600
1000 2400
1001 600
1010 200
1011 134.5
1100 75
1101 50
1110 Invalid
1111 Invalid
Note: A ’1’ in the table above indicates a switch in
the ON position. A ’0’ indicates a switch in the OFF
position

Table 2.1 BAUD RATE SELECTION

COPYRIGHT © 1989 MIILLE APPLIED RESEARCH CO., INC. 2


HOUSTON, TEXAS
RS232/485 CONVERTER 3
INSTALLATION AND OPERATION

2.2.2 NUMBER OF DATA BITS SELECTION

The number of data bits to be transmitted or received is selected using positions 3 and
4 of switch 1.

SWITCH NUMBER OF DATA BITS


34
00 8 Data Bits
01 7 Data Bits
10 6 Data Bits
11 5 Data Bits
Note: A ’1’ in the table above indicates a switch in the ON
position. A ’0’ indicates a switch in the OFF position

Table 2.2 NUMBER OF DATA BITS SELECTION

2.2.3 STOP BIT SELECTION

The number of stop bits expected on receive data and the number to be transmitted is
selected using position 2 of switch S1. If the switch is ON or CLOSED the number of stop bits
will be set to one (1). If position 2 is OFF or OPEN then the number of stop bits will be set to
two (2) except when the number of data bits is selected to be 5. If the number of data bits
selection is 5 then setting position 2 OFF will set the number of stop bits to 1.5 instead of 2.

2.2.4 PARITY SELECTION

A parity bit can be optionally received or transmitted following the last data bit. The
parity selection can be set to be either even, odd or none. Switch positions 1 and 9 of switch S1
are used to select the desired parity options. Table 2.3 defines the possible selections.

SWITCH PARITY SELECTION


91
00 Disabled
01 Disabled
10 Even Parity
11 Odd Parity
Note: A ’1’ in the table above indicates a switch in
the ON position. A ’0’ indicates a switch in the OFF
position
Table 2.3 PARITY SELECTION

COPYRIGHT © 1989 MIILLE APPLIED RESEARCH CO., INC. 3


HOUSTON, TEXAS
RS232/485 CONVERTER 4
INSTALLATION AND OPERATION

2.3 SERIAL INTERFACE CONNECTIONS


A terminal strip is used for connection of the serial interface wiring. The terminal strip is
clearly marked to identify the connections. Table 2.4 details the serial interface connections.

TERMINAL FUNCTION
T Transmitted Data (from RS-485 to RS-232)
R Received Data (from RS-232 to RS-485)
GND Ground Reference
GND Ground Reference
A RS-485 (normally low)
B* RS-485 (normally high)

Table 2.4 SERIAL INTERFACE CONNECTIONS

2.4 POWER CONNECTION


The RS-232/RS-485 Converter can be powered from a low voltage DC or AC source.
The power supply leads should be terminated on the input terminal strips marked ’H’ and ’N’.
There are two positions marked ’H’ and two positions marked ’N’. They are connected in parallel
on the board so either connection can be used. The second set can be used to chain power to
other devices if required. The converter will accept input voltages from 9 to 17 volts, peak, either
AC or DC. The polarity of the applied voltage is immaterial. If an AC source is used it should be
transformer coupled to isolate it from the AC power lines. Note that the input voltage range is
given as volts peak not RMS. The maximum AC input RMS voltage is 12.0 volts.

2.5 PANEL MOUNTING LOCATIONS


The converter board is designed for panel mounting. An integral standoff is located in
each corner of the board. The standoff is 1/4 inch long and has a clearance hole for a number
six screw (.140"). The standoffs are located .200" in from each corner of the board. Figure 2.1
shows the locations of the panel mounting holes.

2.6"

I/O TERMINAL STRIP

3.45"
Figure 2.1 MOUNTING PANEL HOLE LOCATION

COPYRIGHT © 1989 MIILLE APPLIED RESEARCH CO., INC. 4


HOUSTON, TEXAS
RS232/485 CONVERTER 5
SPECIFICATIONS

SPECIFICATIONS

3.1 INTRODUCTION
This section lists the electrical, mechanical and environmental specifications for the
RS-232/RS-485 Converter.

3.2 RS-232/RS-485 CONVERTER SPECIFICATIONS


• Mechanical:
Size: 3.00" W x 3.85" L x 1.25" H
Panel Mounted
Weight: 3 oz.
• Interface:
RS-232 Conforms to EIA RS-232 specifications
Signals Supported Terminal Strip
TD Transmit Data T
RD Receive Data R
GND Ground
RS-485 Conforms to EIA RS-485 specification
• Power:
9 to 17 Volts DC, 70 ma. max.
6.3 to 12 Volts AC (RMS), 70 ma. max.
• Connections:
10-position Clamp Screw Terminal Strip
• Switch Options:
50 to 9600 Baud
5 to 8 Data Bits
1 or 2 Stop Bits
Even, Odd or No Parity
• Environmental:
Operating Temperature 0 to 70 Deg. C.
Storage Temperature -25 to 85 Deg. C.
Humidity 10 to 90% RH, Non Condensing

COPYRIGHT © 1989 MIILLE APPLIED RESEARCH CO., INC. 5


HOUSTON, TEXAS