Oil in Water Analysis Kit: User Manual
Oil in Water Analysis Kit: User Manual
Analysis Kit
User Manual
2I-8900 Issue 5
Oil In Water
Analysis Kit
User Manual
2I-8900 Issue 5
User Manual
USER MANUAL
1. INTRODUCTION ................................................................................. 3
2. UNPACKING AND CHECKLIST ............................................................. 4
3. LOCATING THE CELL IN THE CELL HOLDER ........................................ 5
4. SPARE PARTS .................................................................................. 6
2
Oil In Water Analysis Kit
1. Introduction
Thank you for purchasing a Specac Product.
The Oil In Water Analysis Kit enables the analysis of total recoverable
oil and grease or petroleum hydrocarbons in water using a new
method of analysis D7066-04 approved by the ASTM (American
Society for Testing and Materials). The existing standard EPA methods
413.2 and 418.1 have been replaced as they called for use of Freon as
the extraction solvent for the recovery of oil and grease within a water
sample. Freon is now banned from usage as it is an Ozone depleting
chemical and harmful to the environment. The D7066-04 method is
very similar to the EPA methods but the Freon solvent is replaced by
use of the dimer/trimer of chlorotrifluoroethylene (C2ClF3). This solvent
is known as S-316 and as an IR spectroscopy grade solvent is
manufactured by Horiba Instruments in Irvine, California. (The ASTM
does not advocate the use of one vendor over another for procurement
of the solvent).
The quartz cuvette cells in the Oil and Water Kit are in matched pairs,
which allow for precise repeat measurements of each sample and
therefore continual use of calibration data, even if one cell should be
broken. They also enable the use of the kit in dual beam dispersive
spectrometers when an additional holder is purchased.
3
User Manual
When being used, carefully remove the cells from their packing.
4
Oil In Water Analysis Kit
A) Remove the protective wrapper from the cell holder and the cells.
B) The cell holder is supplied with two different length thumb screws.
After sliding the holder into position onto a spectrometers sample
mounting baseplate via the 3” x 2” back plate, select the
appropriate screw to secure the holder to the baseplate mount.
Choice of screw will depend on the spectrometer.
D) The 50mm and 100mm cylindrical cells lie in the ‘V’ shaped groove
of the cell holder. To secure these cells move the retaining clip
from the vertical post and fix it to the horizontal post attached to
the right hand side of the holder. Use the clip to secure the
cylindrical cell after filling with sample.
For use of the appropriate liquid cell depending upon the level of oil
and grease to be determined, please follow the analytical procedures
as outlined in the method D7066-4 obtainable from the ASTM via the
ANSI webstore website.
5
User Manual
4. Spare Parts
6
Oil In Water Analysis Kit
Notes
7
User Manual
Notes
8
Worldwide Distribution
France Switzerland
Eurolabo - Paris. Portmann InstrumentsAG
Tel.01 42 08 01 28 Biel-Benken
Fax 01 42 08 13 65 Tel: 061 726 6555
email: contact@eurolabo.fr Fax: 061 726 6550
email: info@portmann-instruments.ch
Germany Website:www.portmann-instruments.ch
L.O.T. - Oriel GmbH & Co,
KG - Darmstadt USA
Tel: 06151 88060 SPECAC INC.
Fax: 06151 880689 414 Commerce Drive
email:info@LOT-Oriel.de Suite 175,
Website: www.LOT-Oriel.com/de Fort Washington,
PA 19034, USA
Japan Tel: 215 793 4044
Systems Engineering Inc. -Tokyo Fax: 215 793 4011
Tel: 03 3946 4993
Fax: 03 3946 4983 United Kingdom
email:systems-eng@systems-eng.co.jp Specac Ltd. - London
Website: www.systems-eng.co.jp River House, 97 Cray Avenue,
Orpington
Spain Kent BR5 4HE
Teknokroma S.Coop C. Ltda Tel: +44 (0) 1689 873134
Barcelona Fax: +44 (0) 1689 878527
Tel: 93 674 8800 Registered No. 1008689 England
Fax: 93 675 2405
email: comercial@teknokroma.es
Brilliant Spectroscopy™
www.specac.com