Sika® Carbodur® Calculation Software: PROJECT: Pontilhão ELEMENT: Potilhão MRX
Sika® Carbodur® Calculation Software: PROJECT: Pontilhão ELEMENT: Potilhão MRX
Sika® Carbodur® Calculation Software: PROJECT: Pontilhão ELEMENT: Potilhão MRX
PROJECT: pontilhão
ELEMENT: potilhão Mrx
INDEX
5.- RESULTS............................................................................................................................................................................ 5
5.1.- Summary of results............................................................................................................................................... 5
5.2.- Ultimate limit states............................................................................................................................................. 5
5.3.- Serviceability limit states...................................................................................................................................... 9
5.4.- Fire resistance (t=0 min.)...................................................................................................................................... 10
5.5.- FRP arrangement.................................................................................................................................................. 11
- ACI 440.2R-17
- ACI 318
- Country: Brazil
2.1.- Geometry
Cross section = Slab
Height = 250 mm
250
2.2.- Concrete
Compressive strength of concrete
Concrete strength (f'c) = 30 MPa
Cylinder specimen = 30 MPa
Cube specimen = 37 MPa
To prevent such an intermediate crack-induced debonding failure mode, the effective strain in FRP reinforcement must be
limited to the strain level at which debonding may occur, efd, as defined in Eq. (ACI 440.2R-17, Section 10.1):
f 'c
e fd 0.41 £ 0.9 e fu
n Ef t f
An additional reduction factor for FRP, Yf , is applied to the flexural-strength contribution of the FRP reinforcement. The
recommended value of Yf is 0.85.
Force balance of section. Initial loads
Su = Si = 17.24 kN·m/m
ε = 0.0 ‰
εmin
Strengthening limits. Minimum combination of loads to be resisted by the un-strengthened member (ACI440.2R-17, Section
9.2).
Su = 1.10 · SDL + 0.75 · SLL
f Mn ³ Mu 141.56 kN·m/m ³ 97.23 kN·m/m
Nominal moment Mn : 157.29 kN·m/m
Strength reduction factor f : 0.90
0.0 ‰
εmin
ε = 0.0 ‰
εmin
ε = 0.0 ‰
εmin
The nominal strength of the un-strengthened member exceeds the combination of loads corresponding to the fire situation.
The FRP strengthening is therefore not necessary during a fire situation, and does not need to be protected. If a certain fire
rating is necessary, the designer must evaluate the need for a protection of the RC element (concrete and steel
250
The material shall be a pultruded, unidirectional CFRP plate, and exhibit a fibre volume content >68%.
The material shall have a long track record (> 25 years) for structural strengthening.
Test reports regarding reaction of adhesive joint to artificial weathering after 100 days shall be provided.
The actual strength of the concrete substrate shall be verified with at least three pull-off tests.
The laitance layer on the substrate surface shall be removed and an open-textured surface shall be created.
The material shall not release substances dangerous to health, hygiene and the environment.
The material shall meet the requirements of EN 1504-4 as structural bonding product for bonded plate reinforcement.
The plates shall be cleaned and degreased with Sika® Colma® Cleaner or an Isopropyl alcohol based cleaner.
The adhesive shall be applied to the plates in a way that it is approximately 1 mm thick on the sides and 2 mm thick in the
middle of the plate.
A very thin layer of the adhesive shall be applied to the prepared substrate surface to fill any small voids and irregularities.
The plate shall be placed on the prepared area and pressed onto the substrate, first gently by hand and second with a hard
rubber roller, until adhesive material is squeezed out on both sides of the plate. The excess material shall be removed.
In case of plate intersections, the surface of the underlying plate shall be cleaned from dirt and grease and an adhesive ramp
shall be applied on both sides of the underlying plate so the top plate is connected to the substrate on the entire area.
The freshly bonded system shall not be disturbed for at least 24 hours and any vibrations shall be kept at a minimum during
the curing period of the adhesive.
If necessary, the applied system shall be protected with a suitable coating (compatibility tests between the coating and the
laminate shall be available).
With respect to the software application and results derived from its use, SIKA MAKES NO WARRANTIES OF ACCURACY,
RELIABILITY, COMPLETENESS, MERCHANTABILITY OR FITNESS FOR ANY PURPOSE. THE SOFTWARE APPLICATION IS PROVIDED
ON AN "AS-IS" BASIS AND SIKA EXPRESSLY DISCLAIMS ANY WARRANTIES WITH RESPECT TO THE SOFTWARE APPLICATION
AND RESULTS DERIVED FROM ITS USE.
Sika shall not be liable for any consequential, punitive, incidental, exemplary, or special damages (including but not limited
to loss of business opportunity or loss of profit) arising out of the evaluation or use of the software application and results
derived from its use.
The information, and, in particular, the recommendations relating to the application and end-use of Sika products, are given
in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied
under normal conditions in accordance with Sika’s recommendations. In practice, the differences in materials, substrates
and actual site conditions are such that no warranty in respect of merchantability or of fitness for a particular purpose, nor
any liability arising out of any legal relationship whatsoever, can be inferred either from this information, or from any
written recommendations, or from any other advice offered. The user of the product must test the product’s suitability for
the intended application and purpose. Sika reserves the right to change the properties of its products. The proprietary rights
of third parties must be observed. All orders are accepted subject to our current terms of sale and delivery. Users must
always refer to the most recent issue of the local Product Data Sheet for the product concerned, copies of which will be
supplied on request.
Except as indicated otherwise, all information, text, graphic images, features, functions, and layout contained in this
software are the exclusive property of Sika and may not be copied or distributed, in whole or in part, without the Company's
express written consent.
By transmitting information to Sika, you grant to the Company the unrestricted irrevocable license to use, reproduce,
display, modify, distribute and perform such information. Personal identity information is used by Sika only to process a
request for information by you or for marketing our products and services.
Engineered by: