Concrete Column Design
Concrete Column Design
Concrete Column Design
Engineer: 11/07/2021
Descrip: C-3
ASDIP Concrete 4.4.8 CONCRETE COLUMN DESIGN www.asdipsoft.com
GEOMETRY SLENDERNESS
Width .... 40.0 cm , Height ... 40.0 cm Clear Member Length Lu ....... 3.66 m
Use 8-D25 Longitudinal Bars , ρ = 0.025 OK Effective Length Kx-factor ..... 1.00
Use Ties D10 @ 20.0 cm d' = 6.3 cm OK Effective Length Ky-factor ..... 1.00
Concrete Clear Cover ............. 4.0 cm Lateral Stability .......... Sway Column
Slenderness Ratio = 32 > Limit = 22, Slender
FACTORED LOADS (1st-Order Analysis)
Axial Force Pu ................. 637.6 KN AMPLIFIED FACTORED LOADS
Bottom Top Design Method: Approximate Second Order
Mux due to Gravity .. -5.7 10.5 KN-m Inter-story Drift Δo ........... 0.71 cm
Mux due to Lateral ... 46.2 -14.8 KN-m Moment Magnifier δs ....... 1.19 < 1.5 OK
Story Axial Force ΣPu ...... 97452 KN Amplified Moment Mcx .... 49.5 KN-m
Story Shear Force Vus ..... 1076 KN Mcx / M2 Moment Ratio .... 1.22 < 1.4 OK
INTERACTION DIAGRAM
k= Steel Fs Steel Ms Conc Fc Conc Mc Pn Mn
Condition (KN) (KN-m) (KN) (KN-m) (KN) (KN-m)
c/d
Pure Compression Inf. 1536.1 0.0 3618.0 0.0 5154.1 0.0
Max. Usable Axial 1.20 979.6 61.1 3143.7 95.9 4123.3 157.0
Zero Steel Stress 1.00 792.7 79.0 2619.0 153.9 3411.7 232.9
Steel Stress = 0.5 fy 0.74 375.3 120.8 1947.5 185.0 2322.8 305.8
Balanced Condition 0.59 -38.9 162.3 1550.2 180.5 1511.2 342.8
Steel Strain = 0.005 0.38 -539.6 140.4 982.1 144.4 442.5 284.8
Pure Bending 0.28 0.0 121.6 0.0 118.5 0.0 240.1
Pure Tension 0.00 1624.9 0.0 0.0 0.0 1624.9 0.0
1 of 2
Your Company Name Project: Xentro Mall Tabuk Page # ___
Engineer: 11/07/2021
Descrip: C-3
ASDIP Concrete 4.4.8 CONCRETE COLUMN DESIGN www.asdipsoft.com
COLUMN STRENGTH
Pu Mu k= Steel Fs Steel Ms Conc Fc Conc Mc ϕ ϕPn ϕMn Mu/ϕMn
Comb (KN) (KN-m) (KN) (KN-m) (KN) (KN-m) Factor (KN) (KN-m) Ratio
c/d
User 637.6 49.5 0.44 -345.9 148.8 1145.3 158.3 0.80 637.6 244.9 0.20 OK
2 of 2