Flowsic600 XT
Flowsic600 XT
Flowsic600 XT
FLOWSIC600-XT
THE PERFECT MATCH
2 U l t r a s o n i c g a s f l o w m e a s u r i n g d e v i c e s | SIC K 8018938/2016-06
Subject to change without notice
8018938/2016-06 U l t r a s o n i c g a s f l o w m e a s u r i n g d e v i c e s | SIC K 3
Subject to change without notice
FLOWSIC600-XT Gas flow meters
Measurement data reliability and Simple device integration – even Quick and easy device commis-
availability in compact systems sioning and checks
The FLOWSIC600 ultrasonic gas flow Continuous improvement of ultrasound i-diagnosticsTM helps make device
measuring device already provided technologies has become something commissioning and status checks
best-in-class long-term stability in ex- of a tradition in Dresden, Germany. The quick and easy, and provides extensive
treme ambient conditions, and now the FLOWSIC600-XT boasts state-of-the-art flow meter and application diagnostics
FLOWSIC600-XT combines the features measurement technology, meaning it during operation. Should maintenance
of its predecessor with unprecedented delivers extremely precise measurement ever be required, the intelligent solution
usability. It meets all the requirements results. Compliant with ISO 17089 and assistant provides support. The built-in
for safe and stable custody transfer gas AGA9 and compatible with its prede- infrared interface means measured
measurement throughout its service life. cessor the FLOWSIC600, it can be value and diagnostics data can be
Measurement and diagnostics data and integrated successfully into any system. accessed in no time, making servicing
status changes can be recorded perma- Plus, the new FLOWSIC600-XT Forte quick and efficient.
nently in six accessible data archives, meets the requirements of compact
and the FLOWSIC600-XT’s PowerIn Tech- installations and complies with all of the
nology™ ensures that measurements specifications of OIML R 137 Classes
continue to be taken and data stored in 1.0 and 0.5.
the event of a mains power failure.
4 U l t r a s o n i c g a s f l o w m e a s u r i n g d e v i c e s | SIC K 8018938/2016-06
Subject to change without notice
Gas flow meters FLOWSIC600-XT
8018938/2016-06 U l t r a s o n i c g a s f l o w m e a s u r i n g d e v i c e s | SIC K 5
Subject to change without notice
FLOWSIC600-XT Gas flow meters
IR
6 U l t r a s o n i c g a s f l o w m e a s u r i n g d e v i c e s | SIC K 8018938/2016-06
Subject to change without notice
Gas flow meters FLOWSIC600-XT
i-diagnostics™ – an essential tool for effective and efficient device and application diagnostics
i-diagnostics™ has so much more to offer than just diagnostics – it is an intelligent combination of firmware and software that
means the device is safe, reliable, and easy to use for the entire operating time. i-diagnostics™ builds on the FLOWSIC600’s CBM
(condition based maintenance) smart self-diagnosis functionality, providing useful information about the system status and any
changes to it, in addition to device diagnostics. In order to assess the application, diagnostics data from cross-eyed beams is
first factored in, with application faults, such as blocked flow conditioners, background noise, contamination, and liquids in the
gas, being detected immediately – making lengthy troubleshooting a thing of the past. Process data is constantly assessed on
the basis of the integrated FingerPrint concept. This means that the measurement conditions during calibration can be compared
with the measurement conditions during commissioning and with the current measurement and diagnostics data. An internal
data logger continuously logs measured values for trend analyses to allow the historical measurement processes to be checked,
as well as the results of the self-monitoring. A retroactive thorough check of the measurement process in the form of a graphic
trend analysis is also possible.
FLOWgateTM overview
8018938/2016-06 U l t r a s o n i c g a s f l o w m e a s u r i n g d e v i c e s | SIC K 7
Subject to change without notice
FLOWSIC600-XT Gas flow meters
A
B THE PERFECT MATCH
C Product description
F
and 8 measurement paths to meet ure. These functions help ensure usabil-
the requirements of every application, ity and unparalleled operational safety –
whether it is being used as a stand- and what’s more, the equipment offers
alone or system solution. In addition to the very best possible measurement
the OIML R 137 Class 1.0 requirements, accuracy and long-term stability.
the FLOWSIC600-XT meets the require-
H
ments of Class 0.5 and AGA9 in their
At a glance
K backup operation
Your benefits
L • Low measurement uncertainty in
every application
• Simple device integration – even in
compact systems
• Excellent measurement data reliabili- • Quick and easy commissioning and
M ty and availability
• The right ultrasonic gas flow mea-
checks
N C
®
US
without compromise
O
Additional information
P Fields of application ����������������������������9
Detailed technical data������������������������9
R
Ordering information������������������������� 14
Dimensional drawings����������������������� 14
Dimensions ��������������������������������������� 15
-- www.mysick.com/en/FLOWSIC600-XT
S Instruction for installation ��������������� 18 For more information, just enter the link and get direct access to technical data, CAD design models, operating
instructions, software, application examples and much more.
T 8 U l t r a s o n i c g a s f l o w m e a s u r i n g d e v i c e s | SIC K 8018938/2016-06
Subject to change without notice
Gas flow meters FLOWSIC600-XT
Fields of application
• Custody transfer measurement of natural gas • Onshore and offshore applications
A
• Transport and storage of gas • Gas production applications with H2S and CO2 content
System
Measured values Volumetric flow, a. c., volume a. c., gas velocity, sound velocity, optional volume correction
with integrated EVC
D
E
Number of measuring paths 4, 4+1 (2plex), 4+4 (Quatro), 8 (Forte)
Measurement principle Ultrasonic transit time difference measurement
Measuring medium Natural gas, air, natural gases with contents of CO2, N2, H2S, O2
Measuring ranges
Qmin from ... to 5 ... 750 m³/h
F
Qmax from ... to 1,000 ... 120,000 m³/h
Measuring ranges depend on nominal pipe size
Repeatability ± 0.05 % of the measured value
Accuracy
Error limits Q t ... Qmax H
4-path and 8-path version: ≤ ± 0.5 %
Installation
4-path and 8-path version: ≤ ± 0.3 % for GOST; with uncertainty of the calibration test facility ≤ ± 0.23 %
K
L
4-path version According OIML Class 1.0: with straight inlet section of ≥ 10D or ≥ 5D with flow conditioner
According OIML Class 0.5: with straight inlet section of ≥ 10D and flow conditioner
8-path version According OIML Class 1.0: with straight inlet section of ≥ 2D
According OIML Class 0.5: with straight inlet section of ≥ 5D
Diagnostics functions
For details see operating instructions
i-diagnostics™: integrated device diagnostics and intelligent extended device and application
M
diagnostics via FLOWgate™ software
Gas temperature
–40 °C ... +180 °C
N
O
On request: –194 °C ... +280 °C
Operating pressure
0 bar (g) ... 160 bar (g)
P
On request: 0 bar (g) ... 450 bar (g)
Nominal pipe size
3 ″ ... 56 ″
Q
(DN 80 ... DN 1400),
Other nominal pipe sizes on request
Ambient temperature
R
–40 °C ... +70 °C (–60 °C ... +70 °C with enclosure for electronics)
Storage temperature –40 °C ... +70 °C (–60 °C ... +70 °C meter body only)
Ambient humidity ≤ 95 %
S
Relative humidity; non-condensing
8018938/2016-06
Subject to change without notice
U l t r a s o n i c g a s f l o w m e a s u r i n g d e v i c e s | SIC K 9
T
FLOWSIC600-XT Gas flow meters
B AGA-Report Nr. 9
MID: 2014/32/EU
PED: 2014/68/EU
C
ATEX: 2014/34/EU
EMC: 2014/30/EU
GOST 8.611-2013
GOST 8.733-2011
D Ex-approvals
IECEx Ex db ia op is [ia Ga] IIA /IICT4 Gb
E
Ex db eb ia op is [ia Ga] IIA/IIC T4 Gb
Ex ia op is IIA/IIC T4 Ga
Ex ia nA op is IIC T4 Gc
Ultrasonic transducers intrinsically safe
I
Cl I, Div. 2 Groups A, B, C, D, T4 /Ex ia nA IIC T4 Gc / Cl I Zone 2, AEx ia nA op is IIC T4 Gc
CI I, Div. 1 Groups B, C, D, T4 / Ex d ia [ia Ga] IIC T4 Gb / Cl I, Zone 1 AEx d ia op is [ia Ga] IIC
T4 Gb
CI I, Div. 2 Groups A, B, C, D, T4 / Ex ia nA IIC T4 Gc / Cl I, Zone 2, AEx ia nA op is IIC T4 Gc
J Intrinsically safe:
CI I, Div. 1 Group D T4 / Ex ia IIA T4 Ga / Cl I, Zone 0, AEx ia op is IIA T4 Ga
CI I, Div. 1 Groups A, B, C, D, T4 / Ex ia IIC T4 Ga / Cl I, Zone 0, AEx ia op is IIC T4 Ga
K
Non-incendive:
Cl I, Div. 2, Groups A, B, C, D, T4 / Ex ia nA IIC T4 Gc / Cl I Zone 2, AEx ia nA op is IIC T4 Gc
Ultrasonic transducers intrinsically safe
L Electrical safety
TP TC 012/2011
CE
M Enclosure rating IP 66 / IP 67
Analog outputs 1 output:
4 ... 20 mA, 250 Ω
N
Active/passive, electrically isolated
Digital outputs 4 outputs:
Max. 30 V, 50 mA
Passive, electrically isolated, Open Collector or according to NAMUR (EN 50227),
O Interfaces
fmax = 10 kHz (scalable)
Optical service interface (IR, according IEC 62056-21)
RS-485 (3x)
P
Ethernet TCP/IP (1x optional)
HART master (external pressure and temperature transmitter)
Encoder
Q
Bus protocol Modbus ASCII
Modbus RTU
Modbus TCP
Operation Via display and software FLOWgate™
S Material in contact with media Low temperature carbon steel, stainless steel, duplex steel
T 10 U l t r a s o n i c g a s f l o w m e a s u r i n g d e v i c e s | SIC K 8018938/2016-06
Subject to change without notice
Gas flow meters FLOWSIC600-XT
Electrical connection
Voltage Electrically isolated: 12 ... 24 V DC,
A
6 ... 16 V DC intrinsically safe
Power consumption
PowerIn Technology™ with back-up battery (2,400 mAh, 10.8 V), optional
0.45 W ... 2.45 W
B
Depending on electronics configuration
Integrated components Integrated pressure sensor and temperature sensor for correction of pressure and tempera-
ture effects (option)
C
Volume correction
Correction method PTZ (optional integrated)
D
E
Compressibility SGERG-88
AGA 8 Gross method 1
AGA 8 Gross method 2
AGA NX-19
AGA NX-19 mod.
NX-19 mod. (GOST)
F
GERG91 mod. (GOST)
Fixed value
Data archives 1 diagostics archive (6,000 entries)
2 measurement periodic archives (6,000 entries each)
Logbooks Event log book (1,000 entries)
Parameter log book (250 entries)
Metrology log book (50 entries)
H
I
J
K
L
M
N
O
P
Q
R
S
8018938/2016-06
Subject to change without notice
U l t r a s o n i c g a s f l o w m e a s u r i n g d e v i c e s | SIC K 11
T
FLOWSIC600-XT Gas flow meters
B Qmin
m³/h
Qt 3) Qmax Vmax 2)
m/s
Vt
DN 80 (3″) 5 40 1,000 61 2.5
C DN 100 (4″)
DN 150 (6″)
8
16
65
100
1,600
3,000
63
52
2.6
1.7
D
DN 200 (8″) 20 160 4,500 44 1.6
DN 250 (10″) 25 240 7,000 44 1.5
DN 300 (12″) 35 310 8,000 39 1.5
E DN 350 (14″)
DN 400 (16″)
45
60
420
550
10,000
14,000
36
38
1.5
1.5
DN 450 (18″) 100 700 17,000 37 1.5
F DN 500 (20″)
DN 550 (22″)
130
150
850
1,000
20,000
24,000
35
35
1.5
1.5
DN 600 (24″) 180 1,200 32,000 39 1.5
DN 650 (26″) 240 1,400 35,000 36 1.5
DN 700 (28″) 280 1,700 40,000 36 1.5
H DN 750 (30″)
DN 800 (32″)
320
360
1,900
2,200
45,000
50,000
35
34
1.5
1.5
I
DN 850 (34″) 400 2,500 55,000 33 1.5
DN 900 (36″) 450 2,800 66,000 36 1.5
DN 950 (38″) 500 3,100 70,000 34 1.5
J DN 1000 (40″)
DN 1050 (42″)
550
600
3,400
3,800
80,000
85,000
35
34
1.5
1,5
K
DN 1100 (44″) 650 4,100 90,000 32 1.5
DN 1150 (46″) 700 4,500 95,000 34 1.5
DN 1200 (48″) 750 4,800 100,000 30 1.5
L DN 1300 (52″)
DN 1400 (56″)
900
1,000
5,600
6,500
110,000
120,000
28
27
1.5
1.5
1)
Type approval may limit Qmin/Qmax values.
M 2)
3)
When using an installation configuration with flow conditioner the maximum allowed gas velocity in the pipe is limited to 40 m/s.
Minimum transition flow rate according to MID type approval.
N
O
P
Q
R
S
T 12 U l t r a s o n i c g a s f l o w m e a s u r i n g d e v i c e s | SIC K 8018938/2016-06
Subject to change without notice
Gas flow meters FLOWSIC600-XT
3)
When using an installation configuration with flow conditioner the maximum allowed gas velocity in the pipe is limited to 131 ft/s.
Minimum transition flow rate according to MID type approval. M
N
O
P
Q
R
S
8018938/2016-06
Subject to change without notice
U l t r a s o n i c g a s f l o w m e a s u r i n g d e v i c e s | SIC K 13
T
FLOWSIC600-XT Gas flow meters
A Ordering information
Our regional sales organization will help you to select the optimum device configuration.
C
D
B
D
C
F A E
H
B + 165 mm
I
J
K
D
C
L A E
N
O
B
D
C
P A E
Q
R
S
T 14 U l t r a s o n i c g a s f l o w m e a s u r i n g d e v i c e s | SIC K 8018938/2016-06
Subject to change without notice
Gas flow meters FLOWSIC600-XT
Dimensions
Nominal Connection Standard Weight1) Length (A) Hight (B)2) Flange diame- Width of mea- Internal diame-
A
pipe size flange ter (C) suring section ter (E)
DN 80
Cl. 900
PN 16 DIN 2633
120
75
400
240
461
454
240
200 D
PN 63 DIN 2636 75 454 215
4″
PN 100
Cl. 150
DIN 2637
ANSI B16.5
75
100 300
454
490
230
230 248 95
E
F
Cl. 300 110 490 255
Cl. 600 120 490 275
Cl. 900 130 500 490 290
DN 100 PN 16 DIN 2633 110 300 490 220
PN 63 DIN 2636 120 490 250
H
PN 100 DIN 2637 126 490 265
6″ Cl. 150 ANSI B16.5 128 450 540 280 330 142
Cl. 300 145 540 320
Cl. 600
Cl. 900
170
238 750
540
540
355
380
I
DN 150 PN 16 DIN 2633 140 450 540 285
PN 63
PN 100
DIN 2636
DIN 2637
162
176
540
540
345
355
J
8″ Cl. 150
Cl. 300
ANSI B16.5 255
276
600 617
617
345
380
415 190
K
Cl. 600 316 617 420
DN 200
Cl. 900
PN 16 DIN 2633
360
260
617
617
470
340
L
M
PN 63 DIN 2636 298 617 415
PN 100 DIN 2637 360 617 430
10″ Cl. 150 ANSI B16.5 377 750 691 405 420 235
Cl. 300
Cl. 600
411
485
691
691
445
510
N
Cl. 900 528 691 545
DN 250 PN 16
PN 63
DIN 2633
DIN 2636
383
434
691
691
405
470
O
12″
PN 100
Cl. 150
DIN 2637
ANSI B16.5
486
445 900
691
728
505
485 500 270 P
Cl. 300 494 728 520
Cl. 600
Cl. 900
560
645
728
685
560
610
Q
R
DN 300 PN 16 DIN 2633 441 728 460
PN 63 DIN 2636 509 728 530
PN 100 DIN 2637 585 638 585
S
8018938/2016-06
Subject to change without notice
U l t r a s o n i c g a s f l o w m e a s u r i n g d e v i c e s | SIC K 15
T
FLOWSIC600-XT Gas flow meters
A Nominal
pipe size
Connection
flange
Standard Weight1) Length (A) Hight (B)2) Flange diame-
ter (C)
Width of mea- Internal diame-
suring section ter (E)
(D)
C Cl. 600
Cl. 900
675
850
677
700
605
640
D DN 350 PN 16
PN 63
DIN 2633
DIN 2636
475
625
635
675
520
600
PN 100 DIN 2637 750 705 655
F
Cl. 300 760 844 650
Cl. 600 857 844 685
Cl. 900 926 800 755 705
DN 400 PN 16 DIN 2633 658 762 844 580
PN 63 DIN 2636 794 844 670
18″ Cl. 150 ANSI B16.5 660 820 754 635 620 405
H Cl. 300
Cl. 600
760
960
792
820
710
745
I DN 450
Cl. 900
PN 16
1,300 900 830
Data on request
785
20″ Cl. 150 ANSI B16.5 750 902 815 700 670 450
J Cl. 300
Cl. 600
930
1,080
853
872
775
815
K
Cl. 900 1,500 1,000 892 855
DN 500 PN 16 DIN 2633 700 902 823 715
22″ Data on request
L DN 550
24″ Cl. 150 ANSI B16.5 1,090 991 927 815 760 540
Cl. 300 1,390 978 915
M Cl. 600
Cl. 900
1,615
2,100 1,200
990
1,040
940
1,040
N DN 600
26″
PN 16
Cl. 150
DIN 2633
ASME B16.47
1,015
1,475
991
1,050
940
965
840
870 828 585
Cl. 300 1,825 1,016 972
O Cl. 600
Cl. 900
2,100
2,500 1,250
1,038
1,073
1,016
1,086
P
DN 650 PN16 Data on request
28“ Cl. 150 ASME B16.47 1,950 1,100 1,027 927 862 630
Cl. 300 2,225 1,080 1,035
Q Cl. 600
Cl. 900
2,450
3,000 1,300
1,100
1,150
1,073
1,169
DN 700 PN16 Data on request
R
S
T 16 U l t r a s o n i c g a s f l o w m e a s u r i n g d e v i c e s | SIC K 8018938/2016-06
Subject to change without notice
Gas flow meters FLOWSIC600-XT
Nominal
pipe size
Connection
flange
Standard Weight1) Length (A) Hight (B)2) Flange diame-
ter (C)
Width of mea- Internal diame-
suring section ter (E) A
(D)
DN 900
Cl. 900
PN 16
5,225 1,450 1,396
Data on request
1,461
H
38″ Cl. 150
Cl. 300
ASME B16.47 3,800
3,725
1,300 1,310
1,275
1,238
1,169
1,160 855
I
Cl. 600 4,300 1,325 1,270
DN 950
Cl. 900
PN 16
Data on request 1,421
Data on request
1,461
J
K
40″ Cl. 150 ASME B16.47 3,825 1,350 1,359 1,289 1,213 900
Cl. 300 4,125 1,334 1,239
Cl. 600 4,675 1,375 1,321
DN 1000
Cl. 900
PN 16
Data on request 1,470
Data on request
1,512
L
42″ Cl. 150 ASME B16.47 4,675 1,450 1,415 1,346 1,261 945
Cl. 300
Cl. 600
4,650
5,450
1,386
1,444
1,289
1,404
M
DN 1050
Cl. 900
PN 16
Data on request 1,523
Data on request
1,562
N
44″ Data on request
DN 1100
46″ Data on request
O
P
DN 1150
48″ Cl. 150 ASME B16.47 6,400 1,600 1,574 1,511 1,416 1,080
Cl. 300 6,475 1,552 1,467
Cl. 600
Cl. 900
7,850
12,100 1,900
1,615
1,711
1,594
1,785
Q
DN 1200 PN 16 Data on request
1)
2)
Devices with single SPU; devices with double SPU: weight + 7 kg
Optional neck extension: B + 200 mm
R
S
8018938/2016-06
Subject to change without notice
U l t r a s o n i c g a s f l o w m e a s u r i n g d e v i c e s | SIC K 17
T
FLOWSIC600-XT Gas flow meters
B
≥ 3 DN
≥A 1 ... 5 DN
C
DN
D
A
E
≥A ≥ 3 DN
≥B ≥C 1 ... 5 DN
F
B
H 1 FLOWSIC600-XT
2 Temperature measuring point
I
3 Flow conditioner
J Number of
measuring
paths
OIML R 137 A
Number of
measuring
paths
OIML R 137 A B C
K 4
8
Class 1.0
Class 1.0
10 DN
2 DN
4
4
Class1.0
Class 0.5
5 DN
10 DN
2 DN
2 DN
3 DN
8 DN
8 Class 0.5 5 DN 8 Class 1.0/0.5 5 DN 2 DN 3 DN
L
M
N
O
P
Q
R
S
T 18 U l t r a s o n i c g a s f l o w m e a s u r i n g d e v i c e s | SIC K 8018938/2016-06
Subject to change without notice
Gas flow meters FLOWSIC600-XT
DN
A
C
D
≥A ≥A
≥B ≥C ≥C ≥B
1 DN 1 DN
E
DN
F
B
1 FLOWSIC600-XT
2 Alternative temperature measurement points
H
3 Flow conditioner
A
B
C
D
E
F
H
I
J
K
L
M
N
O
P
Q
R
S
T U l t r a s o n i c g a s f l o w m e a s u r i n g d e v i c e s | SIC K 8018938/2016-06
Subject to change without notice
NOTES
A
B
C
D
E
F
H
I
J
K
L
M
N
O
P
Q
R
S
8018938/2016-06
Subject to change without notice
U l t r a s o n i c g a s f l o w m e a s u r i n g d e v i c e s | SIC K 21
T
NOTES
A
B
C
D
E
F
H
I
J
K
L
M
N
O
P
Q
R
S
T U l t r a s o n i c g a s f l o w m e a s u r i n g d e v i c e s | SIC K 8018938/2016-06
Subject to change without notice
SERVICES
8018938/2016-06 U l t r a s o n i c g a s f l o w m e a s u r i n g d e v i c e s | SIC K 23
Subject to change without notice
SICK AT A GLANCE
8018938/2016-06 ∙ Pre USmod en44
SICK is a leading manufacturer of intelligent sensors and sensor solutions for industrial applications. With
almost 7,000 employees and over 50 subsidiaries and equity investments as well as numerous represen-
tative offices worldwide, we are always close to our customers. A unique range of products and services
creates the perfect basis for controlling processes securely and efficiently, protecting individuals from
accidents and preventing damage to the environment.
We have extensive experience in various industries and understand their processes and requirements.
With intelligent sensors, we can deliver exactly what our customers need. In application centers in Europe,
Asia and North America, system solutions are tested and optimized in accordance with customer specifica-
tions. All this makes us a reliable supplier and development partner.
Comprehensive services round out our offering: SICK LifeTime Services provide support throughout the
machine life cycle and ensure safety and productivity.
Worldwide presence:
Australia, Austria, Belgium, Brazil, Canada, Chile, China, Czech Republic, Denmark, Finland, France,
Germany, Great Britain, Hungary, India, Israel, Italy, Japan, Malaysia, Mexico, Netherlands, New Zealand,
Norway, Poland, Romania, Russia, Singapore, Slovakia, Slovenia, South Africa, South Korea, Spain,
Sweden, Switzerland, Taiwan, Thailand, Turkey, United Arab Emirates, USA, Vietnam.