Type 10

Air Regulators

Pressure Regulator Series

Features Applications
Highly Accurate Industrial processes, inspection procedures,
Pressure Regulation control and analytical instrumentation require
The Bellofram Type 10 Regulator controls precise regulation of air pressure in pipes and
output pressure with an accuracy of 0.1%, vessels. Maintaining constant pressures in
and has very low sensitivity to changes in these applications is usually complicated by
supply pressure and flow. the presence of numerous disturbances, such
Start-Up Stability
as changes in supply pressure, flow, and ambi-
ent temperature, that tend to upset prevailing
The Type 10 Regulator has been designed to conditions.
eliminate the need for any readjustment of the
regulated pressure after long “down time.” Bellofram Pressure Regulators provide accuracy,
At start-up, the regulated pressure will return precision control, and maximum stability under
to its output setting. the most adverse operating conditions.
Flow Stability Type 10
The regulated pressure is held constant over Type 10 Pressure Pressure Regulator Series
substantial changes in flow due to the high-gain Regulator Applications
pneumatic servo amplifier. Particularly good • Gas Mixing
from dead end to 20 cubic meters per hour
• Valve Operators
(12 SCFM).
• Gate Actuators
Automatic High
Downstream Relief Capacity
• Positioner Signal
An integral relief valve provides for exhaust • Calibration Stands
flow whenever the regulated pressure is reset • Air Hoists
to a lower value. The exceptionally large • Air Gauging
capacity of this relief valve assures immedi- • Cylinder Loading
ate response when the downstream regulated • Force Balance Hoists
pressure must be reduced under dead-end
• Disc and Shoe Air Brakes
conditions.
• Clamp Units
Pressure Stability
• Web Tensioning
A high performance servo-operated control • Press Units
mechanism is utilized in the regulator. The
pressure supplied to the pneumatic servo • Roll Loading
amplifier is reduced and held constant.
Locking Capability
The standard Type 10 regulator has a locking
nut which, when tightened, prevents inadver-
tent adjustment of pressure.
Temperature Stability
Shifts in the regulated pressure over wide
ambient temperature variations are minimized
by the use of a measuring capsule made of
specially selected stainless steel alloys.
Proven Reliability
Thousands of Type 10 Regulators are in the field.
Proof of the accuracy of the regulator is reflected
by its use in most air gauging systems and other
precision pressure control applications.
Mounting
The unit may be installed in any position.
It can be panel mounted or supported by in-line
plumbing.

 800.727.5646 • www.marshbellofram.com
Type 10PL

Air Regulators
Plunger Operated Regulator
This reliable plunger operated Plunger Travel
regulator provides unmatched
Pressure Range Plunger Travel*
accuracy and repeatability.
Regulated pressure is changed BAR psig mm inch
by direct linear actuation of 0.1–1.7 2-25 1.9 .075
the plunger instead of turning 0.1–4.1 2-60 2.3 .090
a knob. 0.1–8.3 2-120 2.5 .100
*±10% manufacturing tolerance
Return Spring
0.4 in. (10mm) nominal return height; 7 oz. (200g) approximate preload
Plunger
force; 7.5 lb./in. (135g/mm) approximate spring rate, between 0.4 in.
(10mm) and 0.24 in. (6.5mm) compressed height.
Plunger Knob Material: Steel

The basic Type 10 Regulator is offered with a choice of three port sizes
and three output ranges.

Type 10HR & 10EXHR


High Relief Regulators
Similar in proven accuracy and rugged construction to other Type 10
Regulators, these units provide extra fast “blowdown” for very rapid
release of down stream pressure. The extra relief feature makes these
regulators suitable for cylinder return stroke actuation, air hoists, and
similar applications requiring fast exhaust.

Knob

Type 10LR
Low Range Regulator
The main feature of the Type 10LR is its low-range pressure characteris-
tic. It operates on a maximum of 50 psig / 3.4 BAR supply pressure and of-
fers an output pressure range of 0.5 psig / 0.03 BAR to 25 psig / 1.7 BAR

Tamper Resistant

The Type 10 Regulator is available with The Type 10 Regulator


a tamper resistant cover, as illustrated. is also available with
The cover is threaded over the adjusting bottom ports,
screw to prevent inadvertent or unwar- (Type 10BM)
ranted adjustment of output pressure. consult factory.

www.marshbellofram.com • 800.727.5646 
Type 10LR Type 10 / 10PL Type 10 BM Type 10HR Type 10 EXHR Type 10 HF Type 10 Motorized
Air Regulators

Maximum 50 psig / 3.4 BAR 150 psig / 10.3 BAR 150 psig / 10.3 BAR 150 psig / 10.3 BAR 150 psig / 10.3 BAR 50 psig / 3.4 BAR 150 psig / 10.3 BAR
Supply Pressure
0.5-25, 2-25, 2-60,
2-25, 2-60, 2-120 psig 2-25, 2-60, 2-120 psig 2-120 psig
.5-25 psig 2-120 psig 2-120 psig 2-25 psig
Pressure Ranges 0.03 – 1.7 BAR
0.14–1.7, 0.14–4.1, 0.14–1.7, 0.14–4.1,
0.14–8.3 BAR 0.14–8.3 BAR 0.14–1.7 BAR
0.03–1.7, 0.14–1.7,
0.14–8.3 BAR 0.14–8.3 BAR 0.14–4.1, 0.14–4.1,
0.14–8.3 BAR
Port Sizes 1/4 1/8, 1/4, 3/8 N/A 1/8, 1/4, 3/8 1/8, 1/4, 3/8 3/8 1/8, 1/4, 3/8
0.005 psig / 0.005 psig / 0.005 psig / 0.005 psig / 0.005 psig / 0.005 psig / 0.005 psig /
Effect of Supply 0.3 mBAR 0.3 mBAR 0.3 mBAR 0.3 mBAR 0.3 mBAR 0.3 mBAR 0.3 mBAR
Pressure Variation per 25 psig / per 25 psig / per 25 psig / per 25 psig / per 25 psig / per 25 psig / per 25 psig /
on Outlet Pressure 1.7 BAR change 1.7 BAR change 1.7 BAR change 1.7 BAR change 1.7 BAR change 1.7 BAR change 1.7 BAR change
1/8" / 3.2mm 1/8" / 3.2mm 1/8" / 3.2mm 1/8" / 3.2mm 1/8" / 3.2mm 1/8" / 3.2mm 1/8" / 3.2mm
Sensitivity of water of water of water of water of water of water of water
Bleed Rate 4.8 scfh / 2.3 LPM 4.8 scfh / 2.3 LPM 4.8 scfh / 2.3 LPM 4.8 scfh / 2.3 LPM 4.8 scfh / 2.3 LPM 4.8 scfh / 2.3 LPM 4.8 scfh / 2.3 LPM
Forward Flow Capacity 4 scfm / 113 LPM 14 scfm / 396 LPM 3 scfm / 85 LPM 14 scfm / 396 LPM 14 scfm / 396 LPM 40 scfm / 1132 LPM 10 scfm / 283 LPM
Exhaust Capacity
@ 5 psig (0.4 BAR) 2 scfm / 56 LPM 2 scfm / 56 LPM 2 scfm / 56 LPM 10 scfm / 283 LPM 15 scfm / 424 LPM 2 scfm / 56 LPM 2 scfm / 56 LPM
above setpoint
-20 to 160˚F -20 to 160˚F -20 to 160˚F -20 to 160˚F -20 to 160˚F -20 to 160˚F 0 to 140˚F
Temperature Range -29 to 71˚C -29 to 71˚C -29 to 71˚C -29 to 71˚C -29 to 71˚C -29 to 71˚C -18 to 60˚C
Effect of Changes in 0.25 psig / 0.01 BAR 0.25 psig / 0.01 BAR 0.25 psig / 0.01 BAR 0.25 psig / 0.01 BAR
0.25 psig / 0.01 BAR
Flow on Regulated N/A per 10 scfm / N/A per 10 scfm / per 10 scfm / per 10 scfm / 283
per 10 scfm / 283 LPM
Pressure 283 LPM 283 LPM 283 LPM LPM

Effect of Changes in Flow on Regulated Pressure Manual Type 10 Ordering Information


BAR psig
3.46 50.1 Range
Port Size Control Range
3.45 50.0 0.1–8.3 BAR Type Part Number NPT BAR psig
2–120 psig
3.44 49.9
Supply 10 960-001-000 1/8 0.1–1.7 2-25
3.43 49.8 6.2 BAR 960-003-000 1/4 0.1–1.7 2-25
3.42 49.7 90 psig
SCFM 0 1.7 3.4 5.1 6.8 8.5 10.2 11.9 13.6 15.3 17.0 960-005-000 3/8 0.1–1.7 2-25
m3/hr 0 1 2 3 4 5 6 7 8 9 10
2.08 30.1 Range
10 960-007-000 1/8 0.1–4.1 2-60
Regulated Pressure

2.07 30.0 0.1–4.1 BAR 960-009-000 1/4 0.1–4.1 2-60


2.06 29.9 2–60 psig
Supply 960-011-000 3/8 0.1–4.1 2-60
2.05 29.8 6.2 BAR 10 960-013-000 1/8 0.1–8.3 2-120
2.0 29.7 90 psig
SCFM 0 1.7 3.4 5.1 6.8 8.5 10.2 11.9 13.6 15.3 17.0 960-015-000 1/4 0.1–8.3 2-120
m3/hr 0 1 2 3 4 5 6 7 8 9 10
0.70 10.1 Range 960-017-000 3/8 0.1–8.3 2-120
0.69 10.0 0.1–1.7 BAR 10BM 960-126-000 0.1–1.7 2-25
0.683 9.9 2–25 psig
Supply 960-127-000 N/A 0.1–4.1 2-60
0.68 9.8 6.2 BAR
0.67 9.7 90 psig
960-128-000 0.1–8.3 2-120
SCFM 0 1.7 3.4 5.1 6.8 8.5 10.2 11.9 13.6 15.3 17.0 10HR 960-028-000 1/8 0.1–8.3 2-120
m3/hr 0 1 2 3 4 5 6 7 8 9 10
Effect of Upstream Pressure Variations on Regulated Pressure 960-029-000 1/4 0.1–8.3 2-120
BAR psig 960-030-000 3/8 0.1–8.3 2-120
0.70 10.1 Range
0.69 10.0 0.1–1.7 BAR 10EXHR 960-072-000 1/8 0.1–8.3 2-120
2.5 SCFM
0.68 39.9 2–25 psig 960-073-000 1/4 0.1–8.3 2-120
BAR 2.76 3.45 4.14 4.83 5.52 6.21 6.9
psig 40 50 60 70 80 90 100 960-074-000 3/8 0.1–8.3 2-120
0.70 10.1 Range 10PL 960-019-000 1/8 0.1–1.7 2-25
0.69 10.0 0.1–1.7 BAR
0.683 9.9 2.0 SCFM 960-020-000 1/4 0.1–1.7 2-25
Regulated Pressure

2–25 psig
BAR 2.76 3.45 4.14 4.83 5.52 6.21 6.9 960-021-000 3/8 0.1–1.7 2-25
psig 40 50 60 70 80 90 100
0.70 10.1 Range 10PL 960-022-000 1/8 0.1–4.1 2-60
0.69 10.0 0.1–1.7 BAR 960-023-000 1/4 0.1–4.1 2-60
0.683 9.9 1.0 SCFM 2–25 psig
BAR 2.76 3.45 4.14 4.83 5.52 6.21 6.9 960-024-000 3/8 0.1–4.1 2-60
psig 40 50 60 70 80 90 100 10PL 960-025-000 1/8 0.1–8.3 2-120
0.70 10.1 Range
0.69 10.0 0.1–1.7 BAR
960-026-000 1/4 0.1–8.3 2-120
0.683 9.9 0.2 SCFM 2–25 psig 960-027-000 3/8 0.1–8.3 2-120
BAR 2.76 3.45 4.14 4.83 5.52 6.21 6.9
psig 40 50 60 70 80 90 100 10LR 960-053-000 1/4 0.03–1.7 0.5-25

 800.727.5646 • www.marshbellofram.com
Type 10 Motorized

Air Regulators
Regulator-Motor Specifications
Pressure Regulators
Pressure Range Approximate Time to Cover
Bellofram’s high precision Type 10 pressure regulator – a servo Full Range (seconds)
balanced system in which the main valve is operated by a pilot BAR psig 2 rpm 6 rpm
valve – is also available in a motorized configuration. This combina- 0.1–1.7 2-25 75 25
tion is particularly attractive because it offers low power require- 0.1–4.1 2-60 90 30
ments (2 rpm/4 watts; 6 rpm/6 watts) with extremely high accuracy.
0.1–8.3 2-120 150 50
Applications *±10% manufacturing tolerance

The motorized Type 10 pressure regulator can be used for any


application where electric control of a pneumatic system is desired.
It is often used for remote pressure control and for ventilation sys-
tems. It can also be easily integrated into open or closed loop process
control systems and may be used with programmable controllers.
Features
• Mountable at any angle
• In the event of power failure, the pneumatic output remains
constant at last setting
• Low electrical power requirements
• Adjustable mechanical stop limits maximum output pressure
• No electrical power is required when operating at constant output pressure
• No pre-regulation of supply pressure required
• Built-in overload slip clutch prevents damage to gear train at end of travel,
eliminating the need for limit switches in most applications.
Construction Typical Installation
The regulator and motor are mounted to a bracket and
Control Circuit Diagram
connected to each other through a flexible coupling. The
assembly can be mounted through holes in the bracket.
Motor Specifications
Reversible, synchronous motor with gear drive
and slip clutch.
Operating Voltage 110VAC, 24VAC, 24VDC or 220VAC.
Frequency
60 Hz, Except 220 Vac model is 50 Hz.
Power Consumption (maximum) Note
2 rpm/4 watts, 6 rpm/6 watts. To increase output pressure,
apply voltage to unmarked leads.
Speeds Available 2 and 6 rpm.
To decrease output pressure,
Torque Approx. 8 in. oz. apply voltage to marked leads.
Motorized Type 10 Ordering Information
9 6 0 - 1 8 0 -
Motor Specifications
1 2 RPM 110 VAC 4 WATTS 60 Hz
2 6 RPM 110 VAC 6 WATTS 60 Hz
3 6 RPM 220 VAC 6 WATTS 50 Hz
4 2 RPM 24 VAC 4 WATTS 60 Hz
5 6 RPM 24 VAC 6 WATTS 60 Hz
6 6 RPM 24 VDC
Pressure Range
1 2-25 psig / 0.1–1.7 BAR
2 2-60 psig / 0.1–4.1 BAR
3 2-120 psig / 0.1–8.3 BAR
4 L. R. Model, 0.5-25 psig / 0.03–1.7 BAR
5 H.R. Model, 2-120 PSI / 0.1–8.3 BAR
Port Size
1 1/8 NPT Drawings and dimensions
2 1/4 NPT are for reference only.
3 3/8 NPT