Benjamin Moore - ULTRA SPEC 500
Benjamin Moore - ULTRA SPEC 500
Benjamin Moore - ULTRA SPEC 500
Product Information
Colors — Standard: Technical Data White
White (01)
Vehicle Type Acrylic Copolymer
— Tint Bases: Pigment Type Titanium Dioxide
Benjamin Moore® Gennex® Bases 1X, 2X, 3X, & 4X
Volume Solids 41 ± 2%
— Special Colors: Coverage per Gallon at
350 – 400 sq. ft.
Contact your Benjamin Moore representative Recommended Film Thickness
Benjamin Moore & Co., 101 Paragon Drive, Montvale, NJ 07645 Tel: 866-708-9180 Fax: 201-573-9046 www.benjaminmoore.com M72 N536 US 020419
Ultra Spec® 500 Interior Flat Finish N536
Surface Preparation Application
Surfaces to be painted must be clean, dry, and free of dirt, dust, grease, oil, Stir thoroughly before use. Apply one or two coats. For best results, use
soap, wax, scaling paint, water-soluble materials, and mildew. Remove any a Benjamin Moore® Professional custom-blended nylon/polyester brush,
peeling or scaling paint and sand these areas to feather edges smooth with Benjamin Moore® Professional roller, or a similar product. This product
adjacent surfaces. Glossy areas should be dulled. Drywall surfaces must be can also be sprayed.
free of sanding dust.
New plaster or masonry surfaces must be allowed to cure 30 days before Conditioning with Benjamin Moore® 518 Extender may be necessary
applying base coat. Cured plaster should be hard, have a slight sheen and under certain conditions to adjust open time or spray
characteristics. The chart below is for general guidance
maximum PH of 10; soft, porous or powdery plaster indicates improper cure.
Never sand a plaster surface; knife off any protrusions and prime plaster Mild conditions Severe conditions
before and after applying patching compound. Poured or pre-cast concrete Humid (RH> 50%) with no Dry (RH<50%), in
with a very smooth surface should be etched or abraded to promote direct sunlight & with little direct sunlight, or
adhesion, after removing all form release agents and curing compounds. to no wind windy conditions
Remove any powder or loose particles before priming. Wood substrates
Brush:
must be thoroughly dry. Add 518 Extender
Nylon / Polyester
Difficult Substrates: Benjamin Moore offers a variety of specialty primers or water:
Roller:
for use over difficult substrates such as bleeding woods, grease stains, Premium Quality
crayon markings, hard glossy surfaces or other substrates where paint No thinning Max of 8 fl. oz. to a
3/8" roller cover
adhesion or stain suppression is a particular problem. Your Benjamin necessary gallon of paint
Moore® retailer can recommend the right problem-solving primer for your Spray: Airless
special needs. Pressure: Never add other
1500-2500 psi paints or solvents.
WARNING! If you scrape, sand or remove old paint, you may release lead dust. Tip: 0.015-0.017
LEAD IS TOXIC. EXPOSURE TO LEAD DUST CAN CAUSE SERIOUS
ILLNESS, SUCH AS BRAIN DAMAGE, ESPECIALLY IN CHILDREN.
PREGNANT WOMEN SHOULD ALSO AVOID EXPOSURE. Wear a NIOSH-
approved respirator to control lead exposure. Carefully clean up with a HEPA Thinning/Clean Up
vacuum and a wet mop. Before you start, find out how to protect yourself and your Thinning is unnecessary, but if required to obtain desired
family by contacting the National Lead Information Hotline at 1-800-424-LEAD or application properties, a small amount of clean water may be added.
log on to www.epa.gov/lead.
Never add other paints or solvents.
Primer/Finish Systems Clean up: Use soap and water. Spray equipment should be given a final
New surfaces should be fully primed, and previously painted surfaces may rinse with mineral spirits to prevent corrosion.
be primed or spot primed as necessary. For best hiding results, tint the USE COMPLETELY OR DISPOSE OF PROPERLY. Dry empty
primer to the approximate shade of the finish coat, especially when a containers may be recycled in a can recycling program. Local disposal
significant color change is desired. Special Note: Certain custom colors requirements vary; consult your sanitation department or state-
require a Deep Color Base Primer tinted to a special prescription formula to designated environmental agency on disposal options.
achieve the desired color. Consult your retailer.
Wood, and engineered wood products: Environmental Health & Safety Information
Primer: Ultra Spec® 500 Interior Latex Primer (N534) or Fresh Start® Multi- Use only with adequate ventilation. Do not breathe spray mist or
Purpose Oil Based Primer (024) sanding dust. Ensure fresh air entry during application and drying.
Finish: 1 or 2 coats Ultra Spec® 500 Interior Flat Finish (N536) Avoid contact with eyes and prolonged or repeated contact with
Drywall: skin. Avoid exposure to dust and spray mist by wearing a NIOSH
Primer: Ultra Spec® 500 Interior Latex Primer (N534) or this product. approved respirator during application, sanding and clean up.
Finish: 1 or 2 coats Ultra Spec® 500 Interior Flat Finish (N536) Follow respirator manufacturer’s directions for respirator use. Close
Plaster (Cured): container after each use. Wash thoroughly after handling.
Primer: Ultra Spec® 500 Interior Latex Primer (N534) or Fresh Start® Multi-
Purpose Latex Primer (N023)
Finish: 1 or 2 coats Ultra Spec® 500 Interior Flat Finish (N536)
WARNING Cancer and Reproductive Harm–
Rough or Pitted Masonry:
Primer: Ultra Spec® Masonry Interior/Exterior Hi-Build Block Filler (571) www.P65warnings.ca.gov
Finish: 1 or 2 coats Ultra Spec® 500 Interior Flat Finish (N536)
Smooth Poured or Precast Concrete: FIRST AID: In case of eye contact, flush immediately with plenty of
Primer: Ultra Spec® Masonry Interior / Exterior 100% Acrylic Masonry water for at least 15 minutes; for skin, wash thoroughly with soap
Sealer (608) and water. If symptoms persist, seek medical attention. If you
Finish: 1 or 2 coats Ultra Spec® 500 Interior Flat Finish (N536) experience difficulty breathing, leave the area to obtain fresh air. If
Ferrous Metal (Steel and Iron): continued difficulty is experienced, get medical attention
Primer: Ultra Spec® HP Acrylic Metal Primer (HP04) or Super Spec HP® immediately.
Alkyd Metal Primer (P06)
IN CASE OF SPILL – Absorb with inert material and dispose of as
Finish: 1 or 2 coats Ultra Spec® 500 Interior Flat Finish (N536)
specified under “Clean Up”.
Non-Ferrous Metal (Galvanized & Aluminum): All new metal surfaces
must be thoroughly cleaned with an Oil & Grease Emulsifier Corotech® V600
to remove contaminants. New shiny non-ferrous metal surfaces that will be KEEP OUT OF REACH OF CHILDREN
subject to abrasion should be dulled with very fine sandpaper or a synthetic
steel wool pad to promote adhesion. PROTECT FROM FREEZING
Primer: Ultra Spec® HP Acrylic Metal Primer (HP04)
Finish: 1 or 2 coats Ultra Spec® 500 Interior Flat Finish (N536)
Repaint, All Substrates: Prime bare areas with the primer recommended
Refer to Safety Data Sheet for additional
for the substrate above. health and safety information.
Benjamin Moore & Co., 101 Paragon Drive, Montvale, NJ 07645 Tel: 866-708-9180 Fax: 201-573-9046 www.benjaminmoore.com M72 N536 US 020419
Benjamin Moore, Fresh Start, Gennex, Green Promise, Super Spec HP, Ultra Spec and the triangle “M” symbol are registered trademarks, licensed to Benjamin
Moore & Co. Cradle to Cradle Certified™ is a certification mark licensed by the Cradle to Cradle Products Innovation Institute. All other trademarks belong to their
respective owners. ©2015, 2019 Benjamin Moore & Co. All rights reserved