ACX 780, ACX 781 Access Control Units and Expansion Module
The Infinity ACX 780 is a programmable, stand-alone access controller that is a basic building block
of the Infinity Security Management System. Each ACX 780 controls access to 8 doors, and makes
F E A T U R E S
access decisions based on its own distributed data base. Each door may be controlled by a reader,
• Robust Stand-Alone Eight-Door
keypad, or a combination of both for high security. Up to 62 ACX 780s may be networked to one Access/Security Controller
network controller. In addition, the ACX 780 may be networked with other Infinity controllers
• UL 294, UL 1076 Agency Listings
including the IDX 800 Intrusion Detection Controller, LCX 890 Lighting Controller, and the DCX 250
Touch Screen Display for a fully integrated system. Resident intelligence at the ACX 780 level allows • Peer-to-Peer Communications
Provide Transparent Data
for database storage up to 6,500 cardholders.
Transfer
a built-in UPS provides up to 2 1/2 hours full operation in the event of a power failure.
• UPS Back Up for 2 1/2 Hours Full
Operation
The ACX 781 is designed to meet the access demands of larger sites with storage capacity for up
• Two Built-In Tamper Switches
to 20,000 cardholders on an Infinity system, or 15,000 cardholders on a Continuum system. The ACX with Alarm Notification
781 ensures both high-volume and reliable data storage and fast validation speed at the local
• Software-Selectable Wiegand or
controller level for facilities with thousands of employees, a single perimeter entrance, or a large
ABA Reader Protocols
parking area.
• Wiegand, Proximity, and
Magnetic Stripe Reader Support
With the addition of the field-mountable ACX 781 Expansion Module, personnel record storage
• Support for Up to 8 Keypads and
capacity can be expanded even more. Up to 57,000 card records can be stored in an ACX 781
32 Supervised Alarm Inputs Offers
controller with Infinity versions 2.16 or later; storage capacity increases to 80,000 card records with Optimum Flexibility in Door
Continuum. The Expansion Module mounts conveniently in the door of the ACX 781 controller unit. Control
Power and data communication signals from the ACX 781 to the Expansion Module are provided via
a 25-pin cable.
Infinity ACX 780, ACX 781 Access Control Unit and Expansion Module
COMMUNICATIONS
Communication to the Infinity ACX 780 series is handled via the Infinet bus, a twisted pair, half duplex RS-485 interface.
Communication is accomplished with a token passing protocol which provides full transparent data transfer between all
Infinity controllers on the network. ACX 780 series nodes have priority status on the bus to ensure the fastest possible
alarm throughput.
INPUTS
The ACX 780 contains inputs for eight Wiegand or ABA protocol card readers (software selectable), eight 3 x 4 matrix
keypads, and 32 supervised alarm inputs. (On an Infinity system, the ACX 781 supports Wiegand only.) The alarm inputs can
be used for door status contacts, request-to-exit devices, and any other two-state or three-state (on/off/trouble) alarm
device. Two built-in tamper switches provide alarm notification when either the cabinet door is opened or when the unit is
removed from the wall.
OUTPUTS
The ACX 780 series has eight 5 amp, Form C relay outputs for door control. A ninth Form C relay is available for local
alarm functions, or can be controlled by a custom program residing in the controller. Each output has an integral hand-off-
auto switch for manual operation, and includes software feedback of the switch position.
PROGRAMMING
A fully prompted access control database editor makes data entry easy for reader and door configuration, personnel
changes, scheduling, and alarm definition. Additional database storage capacity is provided at the network controller
level, and at the workstations. Site codes, card formats and other degrade mode parameters are stored in non-volatile
EEPROM in each ACX 780. In addition, the ACX 780 series allows for a maximum event buffer of 1000 events. Events are
automatically uploaded to the workstation when communications resume.
Each door can be configured to operate based on card only, card plus personal ID number (PIN), or keypad only (ACX 781
does not support keypad only). The door’s operating mode can even be changed based on time-of-day or other events for
optimum flexibility, through Andover’s easy-to-use Plain English programming language. Each keypad can also permit entry
of a duress alarm code that can initiate an alarm sequence at any of the controllers or at the workstation.
Time-based anti-passback and entry/egress anti-passback are available to prevent tailgating. Entry/egress anti-passback
is system-wide and can be performed by readers located on different controllers across the network.
Using Plain English, the ACX 780 series can also be used for custom access control sequences such as two-man rule,
optical turnstile control, and man trap configurations.
ACX 780 Dimensional Drawing
9.40 “
(239 mm)
6.70 “ 1.54 “
(171 mm) (39 mm)
ELECTRICAL
Power Consumption: 75 VA ACX 780, ACX 781); 80 VA (ACX 781 w/Expansion Board)
Real-Time Clock: Battery backed clock, synchronized through Infinet by Network Controller.
MECHANICAL
BATTERY
Battery Backup: Two 12V 6.5AH sealed rechargeable batteries programmable for 2 1/2 hours full
UPS/72 hours memory and real-time clock. Expandable by use of greater amp hour
batteries. Charge time will vary. Contact Andover Controls for details.
COMMUNICATIONS
Bus Length: 4,000 ft. (1,220m) standard for Infinet, InfiLink amplification module allows
extension to longer distances and is required after every group of 32 units on the
network.
Bus Media: Infinet: twisted, shielded pair, approved low capacitance cable
INPUTS/OUTPUTS
Inputs
Card Readers: 8
Card Reader Type: Wiegand or ABA, software-selectable. Supports Wiegand, Proximity, and Magnetic
Stripe readers. Wiegand/ABA selection applies to whole panel.
ACX 781: Wiegand only on Infinity systems; Wiegand or ABA on Continuum
systems.
Distance Card Rdr. to ACX 780: 500 ft. maximum using 18 gauge wire
Keypad Inputs: 8
Alarm Inputs: 32
Outputs
Overrides: Each output is equipped with a three-position switch for manual control of the relay.
Switch position is viewable and logged through software.
CONNECTIONS
GENERAL
Copyright 2003
Andover Controls Corporation.
Data subject to change without notice.
All brand names, trademarks and
registered trademarks are the property
of their respective holders. Consult
Andover Product Installation Guides
for exact installation instructions
and specifications.
#DS-ACX780-E