015 Tray Efficiencies PDF
015 Tray Efficiencies PDF
015 Tray Efficiencies PDF
3
Overall Tray Efficiencies
Typical No.
Typical No. Typical
of
Column Service of Actual Overall
Theoretical
Trays Efficiency
Trays
Simple Absorber/Stripper 20 – 30 20 – 30
Steam Side Stripper 5–7 2
Reboiled Side Stripper 7 – 10 3–4
Reboiled Absorber 20 – 40 40 – 50
Deethanizer 25 – 35 65 – 75
Depropanizer 35 – 40 70 – 80
Debutanizer 38 – 45 85 – 90
Alky DeiC4 (reflux) 75 – 90 85 – 90
Alky DeiC4 (no reflux) 55 – 70 55 – 65
Naphtha Splitter 25 – 35 70 – 75
C2 Splitter 110 – 130 95 – 100
C3 Splitter 200 – 250 95 – 100
C4 Splitter 70 – 80 85 – 90
Amine Contactor 20 – 24 4–5
Amine Stripper 20 – 24 45 - 55 9 – 12
Crude Distillation 35 – 50 50 – 60 20 – 30
Stripping Zone 5–7 30 2
Flash Zone – 1st draw 3–7 30 1–2
1st Draw – 2nd Draw 7 – 10 45 – 50 3–5
2nd Draw – 3rd Draw 7 – 10 50 – 55 3–5
Top Draw – Reflux 10 – 12 60 – 70 6–8
Vacuum Column (G.O. Operation)
Stripping 2–4 1
Flash Zone – HGO Draw 2–3 1–2
HGO Section 3–5 2
LGO Section 3–5 2
FCC Main Fractionator 24 – 35 50 – 60 13 – 17
Quench Zone 5–7 2
Quench – HGO Draw 3–5 2–3
HGO – LCGO 6–8 3–5
LCGO – Top 7 – 10 5–7