Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

3kl Superswitch Catalogue 3k 2016

Download as pdf or txt
Download as pdf or txt
You are on page 1of 28

s

Superswitch
Power Distribution Redefined

www.siemens.co.in
Superswitch 3KL8/ 3KA8

Highlights Application
 Switch Disconnector Fuse available  Siemens 3K range of Superswitch SDFs
from 20A to 800A in 2P, 3P, 3P+N & are used as short circuit protection
3P + Switched Neutral Versions. device with fuses and main controls
switches in industrial switchboards
 Switch Disconnector available from 63A
as well as building (residential &
to 1600A.
commercial) switchboards.
 Motor duty as well as Power Distribution
 The switch is also available in Switch
Switches.
Disconnector versions, it ensures
 Superswitch suitable for applications making and breaking of the specified
up to 690V AC. rated current with or without load. At
the same time, they are used for safety
 Suitable for high temperature
isolating function as isolation device in
applications up to 60°C.
various low-voltage circuits.
 Option of isolable neutral as well as
 Superswitch conforms to
switched neutral pole for the entire
IS/ IEC 60947‑3. Superswitch has a very
range.
high life compared to the contemporary
 Increased safety through IP20 Fuse products offered today.
Covers and terminal cover.
 Superswitch 3KL8 is suitable for
 Suitable for Isolation as per protection & switching Motor feeders
IS/ IEC 60947-3. as the complete range is Type-2
Coordinated.
 Unique Positive OFF indication to
indicate the true position of contacts.
 Fuse monitoring provision via 3VU1340
fuse monitor.
 Type 2 Coordinated combination
available for the entire range.
 Rotary handle with telescopic shaft for
depth adjustment.

2
Superswitch 3KL8/ 3KA8

Product Features
 Moving roller contacts
The heart of Superswitch is the self cleaning moving
roller contacts comprising multiple silver-plated copper
rollers which are spring loaded and free to rotate around
their axes and firmly anchored to the moving contact
bridge. With each switching operation the roller contacts
rotate around their axes and move along the knife type
fixed contacts and share the switching current strength.
 Positive OFF indication
High level of safety is offered by Superswitch for the
operating personnel with the Unique Positive OFF
Indication. A GREEN indication flag is actuated directly
Moving Roller Contacts
with the physical movement of the contacts, and not
with the position of the Operating handle which in some
cases may give a false indication if contacts are welded
inside. The sequence of switching operation with the
position of the indicating flag is shown in diagrams
below.
 High Short Circuit Making and Withstand Capacity
Due to multiple rollers the sharing of current reduces
electro-dynamic force and high closing speed ensures
high making capacity. Parallel current paths in roller
contacts ensure high short circuit withstand capacity.
 High Short Circuit breaking Capacity
Due to sharing of Current strength by the parallel rollers,
high breaking capacity is achieved corresponding to the
AC23 utilization category at 550V AC.
 High Electrical Life
Division of current loading leads to reduction of contact
Positive OFF Indication
erosion and offers high Electrical life.

Lyra contacts Moving contacts Fixed contacts

Positive OFF indication

OFF position ON position

3
Superswitch 3KL8/ 3KA8

Product Features

 Positive Isolation
Superswitch satisfies the isolation requirements of
IS/ IEC 60947 standards. This is to ensure that the
contacts inside the Switch are in physically isolated
position when it is in the OFF position. This is tested as
per IS/IEC 60947-3.
Positive Isolation Feature
Also in the OFF position the fuses and the lyra contacts
are not live as they are isolated from both line as well as
load side by the moving roller type contacts. (Please refer
to the schematic on the left side).
 No deration upto 60°C
Superswitch is designed with the indian conditions in
mind where summer temperature in certain areas can
go upto 60°C. 3KL8 can be used without deration upto
an ambient temperature of 60°C.This means that the
customer does not have to select next higher rating for
SDF and offers a great saving in terms of cost and panel
space
 Certifications & Standards
Superswitch is tested in accordance with IS/IEC 60947-3
and is also CE marked
 Availability of Type 2 tested Combinations
3KL8 range of SDFs is truly type tested for type 2
combinations with 3TF contactor and 3UA Birelay.This
helps in easy selection of switchgear for motor feeders
and enhances reliabiility of the system

Tested type 2 combinations

4
Superswitch 3KL8 Switch Disconnector Fuse

Superswitch 3KL8 Switch Disconnector fuses are superior to most other SDFs available in
the market. It offers superior quality, superior technical parameters, higher life in terms of
switching cycles and much more.

Highlights Application
 Conforms to IS/IEC 60947-3 3KL8 Switch Disconnector Fuses are suitable for diverse
applications up to 690V AC, 50/60Hz in Motor feeders
 Range – 20A to 800A
with Direct-on-line, Star-Delta, Soft starters, and VVVF
 Suitable for application up to 690V AC Drive. They are also suitable for, capacitor feeders, motor
control centres, and power control centres. 3KL8 switch
 Available in 2P, 3P, 3P+N and 3P + Switched Neutral
disconnector fuses are also available in special executions
versions
for operations in corrosive environments. Superswitch 3KL8
 Available in Open Execution & SS Enclosure versions is also specially designed for higher ambient temperature
applications and do not require any de-rating upto 60°C.
 Utilization category AC23A at 690V AC
 Suitable for DC Application
 IP20 fuse Cover and terminal covers
 Type-2 coordinated combination available at Iq = 65kA
 Suitable for application up to 60°C without deration

5
Superswitch 3KA8 Switch Disconnector

Highlights Application:
 Conforms to IS/IEC 60947-3 3KA8 Switch Disconnectors are designed to handle wide
ranges of application up to 690V 50Hz AC. 3KA8 can
 Range – 63A to 1600A
be used as a Main Isolator Switch for Inductive Loads,
 Rated utilization category – AC23A at 690V AC small motor loads, mixed loads and Power distribution
application. These Switches can also be used as Isolators in
 Suitable for DC application upto 1000V
DC systems up to 1000V.
 Suitable for application up to 60°C
 Unique Positive Indication Feature
 Unique Roller contact system
 Very High switching Life
 High Short time withstand current

6
Superswitch 3KL8

Accessories for Superswitch

Switched 4th Pole Auxiliary Switch


Certain applications demand Auxiliary switches can be used
switching of the neutral pole for signalling and as part of
along with the main poles.For control circuit of feeders. We can
such requirements Switched 4th install maximum of 1NO+1NC
pole is available as an accessory contacts in switches upto 63A and
upto 160A. 2NO+2NC contacts in switches
upto 800A. They conform to
IS 13947-5.

Castell lock SS Enclosure


In addition to the padlocking Sheet Steel enclosure is available
facility available in Superswitch as an accessory for the entire
a castell key interlock can also be range of Superswitch.
installed in them providing an
additional layer of safety against
unauthorized operation.

DIN Rail mounting Kit Fuse Safety barrier


3KL8 Superswitch upto 63A can Fuse safety barrier provides
be mounted on a 35 mm DIN rail additional safety in the field as
with the help of this accessory. it prevents removal of fuse in
ON condition even if the door
interlock is defeated.

Fuse monitoring system for Superswitch

The motor protection circuit breaker type


3VU1340‑1MS00 is offered with Superswitch for
Fuse monitoring application.
The three poles of this Circuit Breaker are
connected in parallel to the fuses. If any of the
fuses blow, the Circuit Breaker gets actuated
through its release and offers tripping signal
through its auxiliary contacts. Thus the motor is
not subjected to single phasing and costly motor
burn-outs are prevented. 3VU1340-1MS00

7
8UC6 Rotary Operating Mechanism for Superswitch

Features
 The retractable locking device integrated in the handles  Door interlock in OFF position when padlocked
is suitable for padlocks with shackle diameters of 4.5 mm
 Telescopic extension shaft helps the user to readily use it
to 8.5 mm.
for varying panel depth
 Door interlock in ON position with defeat.
 IP 65 degree of protection when installed on Panel door

Ordering info
Shaft Cross Section**
Switching device MLFB
(in mm)

3KL 3KA Size 1 8UC616 6x6

3KL 3KA Size 2 8UC626 8x8

3KL 3KA Size 3 8UC6314-1BB00 12 x 12

3KL 3KA Size 4 8UC6414-1BB00 12 x 12

8UC6 ROH is supplied as standard with Superswitch


** Operating Shafts are also available as spare

8
Superswitch 3KL8 Switch Disconnector Fuse

General Technical Information

Superswitch 3KL8 - Conforms to IS/IEC 60947-3 3KL811 3KL812 3KL815


No. of Poles TP/ TPN/ TPSN
Rated operational voltage Ue @ 50/60 Hz AC V 690 690 690
Rated insulation voltage Ui V 800 800 800
Rated impulse voltage Uimp kV 6 6 6
Rated Operational Current Ie at AC23A @ 690V AC A 20 32 63
Rated Operational Current Ie at AC23A, @ 550V AC A 20 32 63
Mechanical endurance - no. of cycles 25000 25000 25000
Suitable for max. capacitor bank kVAR 12 14 29
Rated Conditional S/C current (rms) with fuses @ 690V AC kA 80 80 80
Rated Conditional S/C current (rms) with fuses @ 500V AC kA 100 100 100
Degree of Protection with Fuse & Terminal cover (from front - panel door open) IP20 IP20 IP20

Superswitch 3KL8 - Conforms to IS/IEC 60947-3 3KL821 3KL822 3KL823


No. of Poles DP/ TP/ TPN/ TPSN DP/ TP/ TPN/ TPSN DP/ TP/ TPN/ TPSN
Rated operational voltage Ue @ 50/60 Hz AC V 690 690 690
Rated insulation voltage Ui V 1000 1000 1000
Rated impulse voltage Uimp kV 8 8 8
Rated Operational Current Ie at AC23A @ 690V AC A 100 125 160
Rated Operational Current Ie at AC23A, @ 550V AC A 100 125 160
Mechanical endurance - no. of cycles 25000 25000 25000
Suitable for max. capacitor bank kVAR 46 58 58
Rated Conditional S/C current (rms) with fuses @ 690V AC kA 80 80 80
Rated Conditional S/C current (rms) with fuses @ 500V AC kA 100 100 100
Degree of Protection with Fuse & Terminal cover (from front - panel door open) IP20 IP20 IP20

Superswitch 3KL8 - Conforms to IS/IEC 60947-3 3KL831 3KL832 3KL833


No. of Poles DP/ TP/ TPN/ TPSN DP/ TP/ TPN/ TPSN DP/ TP/ TPN/ TPSN
Rated operational voltage Ue @ 50/60 Hz AC V 690 690 690
Rated insulation voltage Ui V 1000 1000 1000
Rated impulse voltage Uimp kV 8 8 8
Rated Operational Current Ie at AC23A @ 690V AC A 200 250 315
Rated Operational Current Ie at AC23A, @ 550V AC A 200 250 315
Mechanical endurance - no. of cycles 20000 20000 20000
Suitable for max. capacitor bank kVAR 95 116 145
Rated Conditional S/C current (rms) with fuses @ 690V AC kA 80 80 80
Rated Conditional S/C current (rms) with fuses @ 500V AC kA 100 100 100
Degree of Protection with Fuse & Terminal cover (from front - panel door open) IP20 IP20 IP20

Superswitch 3KL8 - Conforms to IS/IEC 60947-3 3KL834 3KL841 3KL842 3KL843


No. of Poles DP/ TP/ TPN/ TPSN DP/ TP/ TPN/ TPSN DP/ TP/ TPN/ TPSN DP/ TP/ TPN/ TPSN
Rated operational voltage Ue @ 50/60 Hz AC V 690 690 690 690
Rated insulation voltage Ui V 1000 1000 1000 1000
Rated impulse voltage Uimp kV 8 8 8 8
Rated Operational Current Ie at AC23A @ 690V AC A 315 500 630 710
Rated Operational Current Ie at AC23A, @ 550V AC A 400 500 630 800
Mechanical endurance - no. of cycles 20000 15000 15000 15000
Suitable for max. capacitor bank kVAR 186 294 294 374
Rated Conditional S/C current (rms) with fuses @ 690V AC kA 80 80 80 80
Rated Conditional S/C current (rms) with fuses @ 500V AC kA 100 100 100 100
Degree of Protection with Fuse & Terminal cover IP20 IP20 IP20 IP20
(from front - panel door open)

Auxiliary Switch: General Data for 3KL8 Switch Disconnector Fuse 3KL81/2/3/4
Rated Voltage AC 50Hz V 500
Rated Voltage DC V 600
Continuous Current A 10
Rated Operational Current Ie at AC12 @ 415V AC A 10
Rated Operational Current Ie at DC12 @ 110V DC A 4
Maximum Fuse rating for S/C Protection - delayed action cartridge type A 10

9
Superswitch 3KA8 Switch Disconnector

General Technical Information

Superswitch 3KA8 - Conforms to IS/IEC 60947-3 3KA815 3KA821 3KA822 3KA823


No. of Poles TPN TPN/TPSN TPN/TPSN TPN/TPSN
Rated operational voltage Ue @ 50/60 Hz AC V 690V 690V 690V 690V
Rated insulation voltage Ui V 800V 1000V 1000V 1000V
Rated impulse voltage Uimp kV 6kV 8kV 8kV 8kV
Rated uninterrupted current Iu A 80A 100A 125A 160A
Rated Operational Current Ie at AC23A, @ 690V AC A 63A 100A 125A 160A
Rated Operational Current Ie at AC21A, @ 500V AC A 80A 125A 125A 160A
Rated Operational Current Ie at AC21A, AC22A @ 690V AC A 80A 125A 125A 160A
Mechanical endurance - no. of cycles 25000 25000 25000 25000
Rated Short time withstand current Icw (1s) kA 2 8 8 8
Rated Conditional S/C current (rms) with fuses @ 690V AC kA 80kA 80kA 80kA 80kA
Rated Conditional S/C current (rms) with fuses @ 500V AC kA 100kA 100kA 100kA 100kA

Superswitch 3KA8 - Conforms to IS/IEC 60947-3 3KA831 3KA832 3KA834 3KA835


No. of Poles TPN/TPSN TPN/TPSN TPN/TPSN TPN/TPSN
Rated operational voltage Ue @ 50/60 Hz AC V 690V 690V 690V 690V
Rated insulation voltage Ui V 1000V 1000V 1000V 1000V
Rated impulse voltage Uimp kV 8kV 8kV 8kV 8kV
Rated uninterrupted current Iu A 250A 315A 500A 630A
Rated Operational Current Ie at AC23A, @ 690V AC A 200A 250A 400A 630A
Rated Operational Current Ie at AC21A, @ 500V AC A 200A 250A 400A 630A
Rated Operational Current Ie at AC21A, AC22A @ 690V AC A 200A 250A 400A 630A
Mechanical endurance - no. of cycles 20000 20000 20000 15000
Rated Short time withstand current Icw (1s) kA 14 14 20 25
Rated Conditional S/C current (rms) with fuses @ 690V AC kA 80kA 80kA 80kA 80kA
Rated Conditional S/C current (rms) with fuses @ 500V AC kA 100kA 100kA 100kA 100kA

Superswitch 3KA8 - Conforms to IS/IEC 60947-3 3KA843 3KA844 3KA845 3KA846


No. of Poles TPN/TPSN TPN TPN TPN
Rated operational voltage Ue @ 50/60 Hz AC V 690V 690V 690V 690V
Rated insulation voltage Ui V 1000V 1000V 1000V 1000V
Rated impulse voltage Uimp kV 8kV 8kV 8kV 8kV
Rated uninterrupted current Iu A 800A 1000A 1200A 1600A
Rated Operational Current Ie at AC23A, @ 690V AC A 800A 1000A – –
Rated Operational Current Ie at AC21A, @ 500V AC A 800A 1000A 1200A 1600A
Rated Operational Current Ie at AC21A, AC22A @ 690V AC A 800A 1000A – –
Mechanical endurance - no. of cycles 5000 5000 5000 5000
Rated Short time withstand current Icw (1s)* kA – – – –
Rated Conditional S/C current (rms) with fuses @ 690V AC kA 80kA 80kA 80kA 80kA
Rated Conditional S/C current (rms) with fuses @ 500V AC kA 100kA 100kA 100kA 100kA

Auxiliary Switch: General Data for 3KA8 Switch Disconnector 3KA81/2/3/4


Rated Voltage AC 50Hz V 500V
Rated Voltage DC V 600V
Continuous Current A 10A
Rated Operational Current Ie at AC12 @ 415V AC A 10A
Rated Operational Current Ie at DC12 @ 110V DC A 4A
Maximum Fuse rating for S/C Protection - delayed action cartridge type A 10A

* - Upon request

10
Superswitch 3KL8/ 3KA8

Selection Guide: DC Applications

Rating Type Type of Connection DC Rating


Two Poles in series Ie/DC23 @ 220V = 20A
20A 3KL811
Three Poles in series Ie/DC23 @ 440V = 20A
Two Poles in series Ie/DC23 @ 220V = 32A
32A 3KL812
Three Poles in series Ie/DC23 @ 440V = 32A
3KL815 Two Poles in series Ie/DC23 @ 220V = 63A
63A
3KA815 Three Poles in series Ie/DC23 @ 440V = 63A
Two Poles in series Ie/DC23 @ 220V = 100A
3KL821
Three Poles in series Ie/DC23 @ 440V = 100A
100A Two Poles in series Ie/DC23 @ 220V = 125A
3KA821 Three Poles in series Ie/DC23 @ 440V = 125A
----- Ie/DC20 @ 1000V = 100A
3KL822 Two Poles in series Ie/DC23 @ 220V = 125A
125A Three Poles in series Ie/DC23 @ 440V = 125A
3KA822
----- Ie/DC20 @ 1000V = 125A
3KL823 Two Poles in series Ie/DC23 @ 220V = 160A
160A Three Poles in series Ie/DC23 @ 440V = 160A
3KA823
----- Ie/DC20 @ 1000V = 160A
3KL831 Two Poles in series Ie/DC22 @ 220V = 200A
200A Two Poles in series Ie/DC22 @ 440V = 200A
3KA831
----- Ie/DC20 @ 1000V = 200A
3KL832 Two Poles in series Ie/DC22 @ 440V = 250A
250A Two Poles in series Ie/DC22 @ 440V = 250A
3KA832
----- Ie/DC20 @ 1000V = 250A
315A 3KL833 Two Poles in series Ie/DC22 @ 440V = 250A
3KL834 Two Poles in series Ie/DC22 @ 440V = 250A
400A
3KA834 ----- Ie/DC20 @ 1000V = 400A
500A 3KL841 Two Poles in series Ie/DC22 @ 440V = 500A
3KL842 Two Poles in series Ie/DC22 @ 440V = 630A
630A Two Poles in series Ie/DC22 @ 440V = 250A
3KA835
Ie/DC20 @ 1000V = 630A
3KL843 Two Poles in series Ie/DC22 @ 440V = 630A
800A Two Poles in series Ie/DC22 @ 440V = 630A
3KA843
----- Ie/DC20 @ 1000V = 800A
1000A 3KA844 Two Poles in series Ie/DC22 @ 440V = 630A
1250A 3KA845 ----- Ie/DC20 @ 1000V = 1250A
1600A 3KA846 ----- Ie/DC20 @ 1000V = 1600A

Utilisation Categories**
AC21 Switching of resistive loads with moderate overloads
AC22 Switching of mixed resistive and inductive loads including moderate overload
AC23 Switching of Motor or other highly inductive loads
DC20 Connecting & disconnecting load under no-load
DC21 Switching of resistive loads with moderate overloads
DC22 Switching of mixed resistive and inductive loads including moderate overload (eg: shunt motors)
DC23 Switching of highly inductive loads (eg. Series motors)
** To be suffixed with A (Frequent operation) or B (Infrequent Operation)

11
Superswitch 3KL8/ 3KA8

General Ordering Information

3KL8 SDF (DP) 3KL8 SDF (TP)


Ie @ 440V 50Hz AC MLFB Rated current Ie @ SDF suitable for DIN type HRC
690V AC, 50Hz Fuses
100A 3KL8211-2TA00
20A 3KL8111-1TA00
125A 3KL8221-2TA00
32A 3KL8121-1TA00
160A 3KL8231-2TA00
63A 3KL8151-1TA00
200A 3KL8311-2UA00
100A 3KL8211-1TA00
250A 3KL8321-2UA00
125A 3KL8221-1TA00
315A 3KL8331-2UA00
160A 3KL8231-1TA00
400A& 3KL8341-2UA00
200A 3KL8311-1UA00
500A 3KL8411-2UA00
250A 3KL8321-1UA00
630A 3KL8421-2UA00
315A 3KL8331-1UA00
800A& 3KL8431-2UA00
400A$ 3KL8341-1UA00

500A 3KL8411-1UA00
3KL8 SDF (TPN)
630A 3KL8421-1UA00
Ie @ 690V 50Hz AC Order Code
800A$ 3KL8431-1UA00
20A# 3KL8111-3T _ _ 0

32A 3KL8121-3T _ _ 0
3KL8 SDF (TPSN)
63A 3KL8151-3T _ _ 0
Ie @ 690V 50Hz AC MLFB
100A 3KL8211-3T _ _ 0
200A 3KL8311-4UA00
125A 3KL8221-3T _ _ 0
250A 3KL8321-4UA00
160A 3KL8231-3T _ _ 0
315A 3KL8331-4UA00
200A 3KL8311-3U _ _ 0
400A$ 3KL8341-4UA00
250A 3KL8321-3U _ _ 0
500A 3KL8411-4UA00
315A 3KL8331-3U _ _ 0
630A 3KL8421-4UA00
400A$ 3KL8341-3U _ _ 0
800A$ 3KL8431-4UA00
500A 3KL8411-3U _ _ 0

630A 3KL8421-3U _ _ 0
3KA Switch Disconnectors (TPN)
800A$ 3KL8431-3U _ _ 0
Ie @ 440V 50Hz AC MLFB
A DIN Fuse
63A 3KA8151-3TE00
J BS Fuse
100A 3KA8211-3TE00
C NFC Fuse1)
125A 3KA8221-3TE00
0 Open Execution
1) 160A 3KA8231-3TE00
3KL8111/3KL8121/3KL8151 1 Sheet Steel Housing
200A 3KA8311-3UE00
NFC = Cylindrical Fuses
250A 3KA8321-3UE00

400A$ 3KA8341-3UE00
DP - Two Pole
630A 3KA8351-3UE00
TP - Three Pole
TPN - Three Pole + Isolable Neutral 800A$ 3KA8431-3UE00
TPSN - Three Pole + Switched Neutral 1000A 3KA8441-3UE00
$ Rating AC23A @ 550V, This can be utilized to AC23B @ 690V. 1200A@ 3KA8451-3UE00
# AC22A = 32A, AC23A = 20A. 1600A@ 3KA8461-3UE00
@ Rating AC21 at 500V, 50Hz AC
& Rating AC23A @ 550V, This can be utilized to AC23B @ 690V.
Switched neutral as accessory for the Size 1-2

12
Superswitch 3KL8

Fuse Selection Guide

Ie SDF Type DIN Fuse Size DIN Fuse Type BS Fuse Size BS Fuse Type NFC Fuse Size

20A 3KL8111 00/000 3NA78 A2/A3 TSA/TIA 14X51

32A 3KL8121 00/000 3NA78 A2/A3 TSA/TIA 14X51

63A 3KL8151 00/000 3NA78 A3 TIS/TSS 14X51

100A 3KL8211 00/000 3NA78 A4 TCP –

125A 3KL8221 00/000 3NA78 A4 TCP/TSFP –

160A 3KL8231 00/000 3NA78 A4 TCP/TSFP –

200A 3KL8311 1-2 3NA71, 72 B2/B3/B4 TSF/TF –

250A 3KL8321 1-2 3NA71, 72 B2/B3/B4 TSF/TF/TKF/TSK –

315A 3KL8331 1-2 3NA72 B2/B3/B4 TSF/TF/TKF/TSK –

400A 3KL8341 1-2 3NA72 B2/B3/B4 TSF/TF/TKF/TSK/TMF –

500A 3KL8411 3 3NA33 C1/C2/C3 TTM –

630A 3KL8421 3 3NA33 C1/C2/C3 TTM –

800A 3KL8431 3 3NA33 C1/C2/C3 TSLS –

MLFB Structure

3 K L 8 1 1 1 3 T A 0 0

0 – Normal Atmosphere
L – Switch Disconnector Fuse 1 – Corrossive Atmosphere
A – Switch Disconnector
X – Accessories
0 – Open Execution, Standard
1 – Enclosed

1-4 Frame Size

A – DIN Fuse
1-6 Current rating C – NFC Fuse
J – BS Fuse

1 – Three Pole
2 – Two Pole
T – Handle with Fixed Coupler
3 – Three Pole+ Isolable Neutral
U – Handle with Movable Coupler
4 – Three Pole+ Switched Neutral

13
SuperSwitch 3KL8/3KA8

Accessories for Superswitch

3KL811/12/15 3KL821/22/23 3KL831/32/33/34 3KL841/42/43


Image Description
3KA815 3KA821/22/23 3KA831/32/34/35 3KA843/44/45/46

Fuse Cover 3KX8150-0AC 3KX8230-0AC 3KX8340-0AC 3KX8430-0AC

Terminal Cover – 3KX8231-0AC 3KX8341-0AC 3KX8431-0AC

Isolable Neutral cover – 3KX8232-0AC 3KX8342-0AC 3KX8432-0AC

Phase Barrier 3KX8153-0AC 3KX8233-0AC 3KX8343-0AC 3KX8433-0AC

Auxiliary Switch
3SB5400-0A 3KX3522-1YC 3KX3552-1YC 3KX3582-1YC
(1NO+1NC)

Auxiliary Switch
– 3KX3522-1YD 3KX3552-1YD 3KX3582-1YD
(2NO+2NC)

Auxiliary switch cover 3KX8154-0AC 3KX8234-0AC – –

Front Drive
8UC616 8UC626 8UC6314-1BB00 8UC6414-1BB00
(Handle)

3KX3588-1YN
Add on Switched 4th (3KL841/2/3) (3KA843/4)
3KX8155-5AC 3KX3528-1YN 3KX3558-1YN
Pole 3KX8465-6AC
(3KA845/6 )

14
Accessories for Superswitch

3KL811/12/15 3KL821/22/23 3KL831/32/33/34 3KL841/42/43


Image Description
3KA815 3KA821/22/23 3KA831/32/34/35 3KA843/44/45/46
3KX8225-7AC 3KX8345-7AC 3KX8435-7AC
3KX8125-7AC
(3KL821/822) (3KL831/2/3/4) (3KL841/2/3)
(3KL811/3KL812)
Add on neutral link (3KA821/822) (3KA831/2//4) (3KA843/4/5/6)
3KX8155-7AC 3KX8235-7AC
(3KL815/3KA815) (3KL823) (3KA823)
3KX8425-6AC
3KX8315-6AC
(3KL841/42)
3KX8225-6AC (3KL831) (3KA831)
3KX8125-6AC 3KA835
(3KL821/822)
(3KL811/ 3KL812) 3KX8335-6AC
(3KA821/822)
Add-on Isolable neutral (3KL832/3)
(3KA832)
3KX8435-6AC
3KX8155-6AC 3KX8235-6AC 3KX8345-6AC
(3KL843)
(3KL815/3KA815) (3KL823) (3KA823) (3KL834)(3KA834)
(3KA843/4/5/6)

Key interlock – – 3KX3588-1YP(.) # 3KX3588-1YP(.) #

Castell Interlock1 8UC6070-0YQ.. 8UC6070-1YQ.. 8UC6070-2YQ.. 8UC6070-2YQ..

Depth setting template 8UC6046

DIN Rail mounting kit 3KX8155-3AC – – –

Fuse Monitor 3VU1340-1MS00

Adapter Plate to
replace old 3KL with 3KX8155-1AC – – –
3KL8

Fuse safety Barrier 3KX8150-1AC 3KX8230-1AC – –

SS Enclosure 3KX8155-4AC 3KX8235-4AC 3KX8345-4AC 3KX8435-4AC

1 The 11th and 12th place of the type reference will indicate the alphabet type of lock & key. Combinations available are A, B, C, D, A-, -B, -C, AB, AC.
11th place will be A, B, C, D for castell lock type A, B, C, D respectively. 11th and 12 place will be A0, 0B, 0C, AB, AC for castell lock type A-, -B, -C,
AB, AC respectively.

# Type of keys are Type A-F depending on the last digit (.) to be replaced by letters A-F.

15
LV HRC Fuses

DIN Type Fuse

Short data description: 3NA7 LV HRC Fuses whether healthy or blown. This necessitates requirement of
additional front indication.
Standards IS 13703 Part 2 Section 1(1993); IEC 269
Dimensions IS 13703; IEC 269 The combination indicator Fuse has two indicators as
against one indicator in conventional fuses. One indicator
Operating class gG
is on top cover plate similar to conventional fuses and other
Rated Voltage AC 500V / DC 440V upto 630A indicator is at the centre of the ceramic body of the fuse
(DC 250V for size 00)
link. This helps in clear identification of status of fuse even
AC 690V/DC 440V (DC 250V for size 00) from front side.
Rated Current Range 2 to 800A: (500 Vac) 800A@415V.
3NA7 LV HRC Fuses are available in 5 different sizes from
40 to 500 A (690 Vac) 2 to 800A. The main part of the LV HRC fuses is the fuse
Rated Breaking Capacity AC 120kA / DC 25kA element of high-grade copper. The important factors are
Mounting position as desired but preferably vertical the reistance value per meter, the material thickness and
Resistance to climate -30° C to +50° C at 95% relative humidity
the dimensional accuracy. Three criteria decisive in the
production of the fuse elements are:
 Accurate cutting and punching
LV HRC Fuses  Precise application of the solder deposit
During installations, when the conventional HRC Fuses  Accurate and concentric insertion of the fuse-element in
are mounted on the fuse bases or Switch Disconnector the fuse body.
Fuse Units in panels as in Fuse Rails above certain height,
Where several fuse elements are involved, these are fitted
it is very difficult to identify the status of the fuse link
exactly parallel to each other in the fuse body. This ensures
adequate cooling of the individual arcs. The precision of the
parallel arrangement can be verified by observing the beads
of molten metal after the fuse has switched off a short
circuit. The fuse-element must not be too close to the wall
of the fuse body as otherwise there is no protective layer of
sand. If the arc were to touch the wall of the fuse body, the
fuse might burst or blow.
The fuse elements of 3 NA7 fuses are of operating class gG
and of copper. The use of silver-plated or pure silver fuse-
elements is not required for physical reasons.
Oxidation, also called scalling of copper, which reduces
the cross-section of the fuse-element, occurs only at a
temperature of approx. 350° C. In the time/current range
Indicator not Released - Healthy Fuse within which a fuse operates, however, only temperatures
of 180° C to 240° C are attained. Hence safe tripping is
ensured with this fuse element.

Advantages
 Consistently high quality LVHRC fuses
 Least stresses to downstream equipments during short
circuit due to lower let through current
 Low power losses resulting in high economy and minimal
heating.
 Safe and reliable breaking capacity from the smallest and
dangerous overload current upto the largest short-circuit
current.
 Finely graded selectivity level for the optim use of cable
cross sections
 High resistance to ageing thus avoids unnecessary
operational faults
Indicator Released- Blown Fuse  Constant characteristics even under different
temperature conditions

16
LV HRC Fuses

DIN Type Fuse LV HRC fuse links


 According to IEC 60269/IS 13703
 Rated voltage: 500 V AC / 415 VAC for 800 A
 Rated voltage (DC): 440 V DC, upto 630A (250 V for size
000/00)
Selection & Ordering Data  Utilization Catagory gG#
LV HRC fuses: 500V AC  Rated breaking capacity : 120 kA (AC), 25 kA (DC)

Rating Let Through Energy


Size Order Watt Loss
A (I2T)
2 3NA7 802-0RC 1.3 9
4 3NA7 804-0RC 0.9 27
6 3NA7 801-0RC 1.3 150
10 3NA7 803-0RC 1 370
16 3NA7 805-0RC 1.7 1,000
20 3NA7 807-0RC 2 1,900
000 25 3NA7 810-0RC 2.3 3,300
32 3NA7 812-0RC 2.6 6,400
40 3NA7 817-0RC 3.1 12,100
50 3NA7 820-0RC 3.8 16,000
63 3NA7 822-0RC 4.6 26,500
80 3NA7 824-0RC 5.8 43,000
100 3NA7 830-0RC 6.6 80,000
125 3NA7 832-0RC 8.9 130,000
00
160 3NA7 836-0RC 11.3 223,000
50 3NA7 120-0RC 4.6 6,800
63 3NA7 122-0RC 6 9,800
80 3NA7 124-0RC 7.5 16,000
1
100 3NA7 130-0RC 8.9 30,600
125 3NA7 132-0RC 10.7 50,000
160 3NA7 136-0RC 13.9 85,000
200 3NA7 140-0RC 15 135,000
1 224 3NA7 142-0RC 16.1 170,000
250 3NA7 144-0RC 17.3 230,000
200 3NA7 240-0RC 14.9 135,000
2
250 3NA7 244-0RC 17.9 230,000

315 3NA7 252-0RC 21.4 433,000

400 3NA7 260-0RC 27.5 676,000

315 3NA3 352-0RC 21.4 433,000


400 3NA3 360-0RC 27.5 676,000
500 3NA3 365-0RC 36.5 1,270,000
3
630 3NA3 372-0RC 44 2,700,000

*800 3NA3 375-4RC 51.9 2,740,000

* 800A fuses - Rated Voltage at 415V AC.

17
LV HRC Fuses

DIN Type Fuse LV HRC fuse links


 According to IEC 60269/IS 13703
Selection & Ordering Data  Rated voltage: 690V AC
LV HRC fuses : 690V AC  Rated voltage (DC): 440V DC, (250V for size 00)
 Utilization Category gG#
 Rated short circuit breaking capacity:
120kA (AC), 25kA (DC)

Rating Order
Size
A No.

00 40 3NA7 817-6RC
50 3NA7 820-6RC
63 3NA7 822-6RC
80 3NA7 824-6RC
100 3NA7 830-6RC

125 3NA7 132-6RC


1 160 3NA7 136-6RC
200 3NA7 140-6RC

250 3NA7 244-6RC


2
315 3NA7 252-6RC

400 3NA3 360-6RC


3 425 3NA3 362-6RC
500 3NA3 365-6RC

Utilization category as per VDE 0636/IEC 60269


Semiconductor aR, gR, gS
Cable & Conductor gG
Switchgear / Motor aM

1st letter 2nd letter


a = Partial range of protection (accompanied fuses) G(-L) = Cable & conductor protection (general purpose fuses)
g = Complete range protection (general purpose fuses) M = Switchgear / Motor protection (Motor Circuit Protection)
R, S = Semiconductor protection

18
LV HRC Fuses

BS Type Fuse

General
Siemens low voltage HRC fuses of BS type have been
developed for industrial applications. Due to the special
design, they provide high rupturing capacity combined with
low temperature rise under normal load conditions. The
quick acting characteristics of the fuses ensure that under
the worst fault conditions, cut off occurs before the peak
value of fault current is reached. This ultimately reduces the
electromagnetic stress and fire risk, thus avoiding premature
failure of the downstream equipment.

Construction
The fuse links consist of one or more elements contained
in ceramic barrel of exceptional strength and filled by
carefully graded, chemically purified silica quartz sand. The
end of cartridges are closed by electro-tinned/ silver plated
end caps which are forced on to the ground barrel under
pressure, thus entirely eliminating the use of cement with
its attendant disadvantages.
The fuse elements are made of pure copper/ silver
composite type and manufactured to very close tolerance to
ensure that the characteristics of the fuses are consistent.
All fuse links are manufactured under strict quality control
and tested as per relevant standards.

Applications
The fuses are ideally suited for general industrial
applications as well as protection of lighting and heating
circuits.

Short Data Description

BS Fuses - Type 3NW

Rated Voltage : 415V AC, 240V DC

Rated Current : 2A to 800A

Rated short circuit : 80kA (AC), 40kA (DC)


breaking capacity

Utilization Category : gG

Fusing Factor : 1.6

Fuse fixing arrangement : Blade Tag, Offset Tag,


Centre Tag

Relevant Standards : IS13703-2 (1993),


BS 88 Part 1 & 2 (1988),
IEC 60269 –2-1(1987)

19
LV HRC Fuses

Selection & Ordering Data

Rated Power Rated Power


Rated Rated
Type Type Reference Dissipation Type Type Reference Dissipation
Current (A) Current (A)
(Watts) (Watts)

Offset Tag 2 3NW TIA2 1.5 Centre Tag 80 3NW TSDC80 7.2
4 3NW TIA4 2.7 100 3NW TSDC100 8.5
6 3NW TIA6 3.3
10 3NW TIA10 2.8 Centre Tag 80 3NW TC80 7.2
16 3NW TIA16 3.3 100 3NW TC100 8.2
20 3NW TIA20 3.1
Centre Tag 125 3NW TF125 10.0
25 3NW TIA25 3.6
160 3NW TF160 13.0
32 3NW TIA32 3.8
200 3NW TF200 16.0
Offset Tag 6 3NW TSA6 1.8
Centre Tag 125 3NWTSF125 11.0
10 3NW TSA10 2.1
160 3NW TSF160 13.0
16 3NW TSA16 1.8
200 3NW TSF200 14.0
20 3NW TSA20 1.8
25 3NW TSA25 2.0 Centre Tag 250 3NW TKF250 19.0
32 3NW TSA32 2.9 315 3NW TKF315 25.0
Offset Tag 40 3NW TIS40 4.7 Centre Tag 250 3NW TSK250 18.0
50 3NW TIS50 4.9 315 3NW TSK315 22.0
63 3NW TIS63 5.6
Centre Tag 355 3NW TSMS355 24.0
Offset Tag 36 3NW TSS36 4.4 400 3NW TSMS400 29.0
40 3NW TSS40 4.7
50 3NW TSS50 4.9 Centre Tag 355 3NW TMF355 24.0
63 3NW TSS63 5.6 400 3NW TMF400 29.0

Offset Tag 80 3NW TCP80 7.2 Centre Tag 450 3NW TSTS450 31.0
100 3NW TCP100 8.2 500 3NW TSTS500 39.0

Offset Tag 80 3NW TSDS80 7.2 Centre Tag 500 3NW TTM500 38.0
100 3NW TSDS100 8.5 630 3NW TTM630 50.0

Offset Tag 125 3NW TSFP125 11.0 Centre Tag 560 3NW TSLS560 38.0
160 3NW TSFP160 13.0 630 3NW TSLS630 44.0
200 3NW TSFP200 14.0 800 3NW TSLS800 68.0

Offset Tag 125 3NW TFP125 10.0 Centre Tag 710 3NW TLM710 53.0
160 3NW TFP160 13.9 800 3NW TLM800 64.0
200 3NW TFP200 16.0

20
Dimension Details: Superswitch 3KL8/ 3KA8 - Size 1

Drilling plan for mounting plate

Type A
3KL 811/12 M5
3KA/3KL 815 M6

8UC Depth Value

8UC6 Type Kmin Kmax


8UC616 183 240

3KL 3KA
WITH ACCESSORIES WITHOUT ACCESSORIES

Dimension Details for SDF in Enclosure

# All the dimensions are in mm # All the dimensions are to scale


# Terminal Shroud, Fuse Cover, Phase Barrier are standard feature of 3KL TPN switches only

21
Dimension Details: Superswitch 3KL8/ 3KA8 - Size 2

Drilling plan for mounting plate

1
2

Type A B

Type C D F I K M N 3KL/3KA 821/822 20 41

ISO Neutral 100A/125A 12 2 14 20 22 74 90 3KL/3KA/3KT 823 25 43.5

ISO Neutral 160A 15 3 17 25 27 85 100

8UC Depth Value

8UC6 Type Kmin Kmax


8UC626 183 240

3KA 3KL
WITHOUT ACCESSORIES WITH ACCESSORIES

Dimension Details for SDF in Enclosure

# All the dimensions are in mm # All the dimensions are to scale


# Terminal Shroud, Fuse Cover, Phase Barrier are standard feature of 3KL TPN switches only
1 Supplied as standard with the Switch 2 Available as accessory

22
Dimension Details: Superswitch 3KL8/ 3KA8 - Size 3

Drilling plan for mounting plate

Center of shaft

8UC Depth Value

3KL/3KT 3KA
WITH ACCESSORIES WITHOUT ACCESSORIES

G K
Type A B C D E F H J M L
min max min max
3K3
3KL/3KT 831/832/833 30 12.5 75.5 4 214 239 3 30 72.8 5.5 287 313 285 310
3KA 831/832
3K3
40 15 75.5 4 229 259 3 30 72.8 5.5 287 313 285 310
3KA 834
3K3
40 15 67.5 6 240 270 3 30 72.8 5.5 287 313 285 310
3KL/3KT 834
3K3
40 15 67.5 6 240 270 4 30 72.8 5.5 233 259 231 256
3KA 835
3K1
3KL 831/832/833 25 12.5 53.5 4 186.4 211.4 – – – – 233 259 231 256
3KA 831/832/834
3K1
3KA 835 25 12.5 55.5 6 191 216 – – – – 233 259 231 256
3KL 834

# All the dimensions are in mm # All the dimensions are to scale


# Terminal Shroud, Fuse Cover, Phase Barrier are standard feature of 3KL TPN switches only

23
Dimension Details: Superswitch 3KL8 - Size 4

3KL84
Drilling plan for mounting plate

Center of
shaft

8UC Depth Value

Type E
ISO Neutral 315A 5
ISO Neutral 400A 5
ISO Neutral 630A 6
ISO Neutral 800A 8

WITH ACCESSORIES WITHOUT ACCESSORIES

G K
Type A B C D F H
min max min max
3K3
3KL/3KT 841/842/843 55 22 288 332 95 M16 287 313 285 310
3KA 843/844
3K1
40 20 230 270 39 M12 287 313 285 310
3KL 841/842/843

# All the dimensions are in mm # All the dimensions are to scale


# Terminal Shroud, Fuse Cover, Phase Barrier are standard feature of 3KL TPN switches only

24
Dimension Details: Superswitch 3KA8 - Size 4

Drilling plan for mounting plate

Center of
shaft

G K
Type A B C D E F H I J L M
min max min max
3KA2
3KA3 40 6 64.4 20 – – 274 – – 153.9 234 312.4 338.4 310.4 335.4
843/844
3KA2
3KA3 50 10 58.4 – 40 20 – 314 354 159.9 234 312.4 338.4 310.4 335.4 8UC Depth Value
845/846
3KA84513UE00/
50 10 114 – 40 20 – 392 432 – 312 299.7 325.7 310.4 335.4
3KA84613UE00

Dimension Details for SDF in Enclosure 3KL831/2/3/4, 3KL841/2/3

Type of SDF A B C D E F G H I J
3KL831/2 80 4 425 300 60 215 26.5 180 176 6.5
3KL834 75 6 425 300 60 215 26.5 180 176 6.5
3KL842 95 6 425 395 96 262 25 208 223.5 2.5

Type of SDF A B C D E
3KL831/2/3/4 370 180 15 60 40
3KL841/2/3 360 208 40 96 40

# All the dimensions are in mm # All the dimensions are to scale

25
Dimensional Drawing: DIN Fuse

t1 t2

Sizes Rating MLFB b h1 h2 t1 t2

h1
h2
000 2A - 100A 3NA78... 21 54 80 45 8

00 125A - 160A 3NA78... 30 54 80 45 14

1 50A - 160A 3NA71... 30 75 137 50 15

1 200A - 250A 3NA71... 47 75 137 51 9

2 200A - 250A 3NA72... 47 75 151 58 10


b

2 315A - 400A 3NA72... 58 74 151 59 13

3 315A - 800A 3NA33... 71.2 74 151 69.5 12.8

Dimensional Drawing: BS Fuse

Current Rating
Type Reference A B C D E F G H I
Range Amps.

3NW TIA 2-32 53.00 73.00 85.00 22.00 22.10 9.20 7.90 5.40 1.00

3NW TSA 6-32 35.50 73.50 85.00 13.70 14.00 8.70 8.00 5.50 1.20

3NW TIS 40-63 54.50 73.50 87.00 21.00 22.50 12.70 8.00 5.50 1.20

3NW TSS 36-63 54.50 73.50 87.00 21.00 22.50 12.70 8.00 5.50 1.20
Off-Set Tag
3NW TCP 80-100 66.00 94.00 111.00 35.50 37.00 20.00 10.30 8.70 2.64

3NW TSDS 80-100 54.50 73.00 95.00 21.00 22.50 12.70 8.00 5.50 1.20

3NW TSFP 125-200 47.00 94.00 110.00 31.00 29.50 19.00 10.00 9.00 3.20

3NW TFP 125-200 66.00 94.00 111.00 38.00 38.00 19.00 10.00 8.50 2.64

Note: For dimensions of other ratings and types of BS fuses suitable for Superswitch; please refer to the BS Fuse Datasheet.

26
Type-2 Co-ordination Charts: Superswitch 3KL8

Fuse protected selection type 2, lq = 65kA, IS/IEC 60947-4-1


• The selection is valid only for complete Siemens combinations i.e. SDF + DIN Fuse + Contactor + Birelay (+ timer).
• In case this combination is changed to accommodate another brand/rating of SDF/DIN Fuse/Contactor/BMR,
it shall be the responsibility of the person making such a change to assure type 2 performance.
• Selection is for normal starting conditions with starting time ≤ 6 seconds. For heavy starting applications, please consult Siemens.
• At 60oC service temperature the bi-relay has to be derated. The bi-relay can be used upto the maximum current setting indicated. For
example - A bi-relay with setting 32-50A, at 60oC can be used only upto 47A. This however does not mean that at 60oC, the 50A setting
corresponds to 47A. It means that, the bi-relay should not be set beyond 47A.
• The electronic star-delta timer type 3RP should be used in star-delta feeders.
• SDF: Switch Disconnector Fuse. All contactors are with 2NO + 2NC. All fuses are proper DIN HRC type.
• Tested Type 2 combinations
• Low LCC = Low Life Cycle Cost

Direct-on-line feeder, for Low LCC


SL Motor Motor SDF HRC Fuse Contactor Bi-Relay Bi-Relay
kW/HP 415V, IL Set-Range Available Set-
Type Rating Type 3NA7 Amp Type Amp Type (50°C) Type (60°C)
3ph, 50 Hz Amp Amp Range Amp
0.37/0.5 1 3KL811 20 3NA7804 4 3TF30 9 3UA5000-0K 0.8 - 1.25 3UA5000-0K 0.8 - 1.17
0.55/0.75 1.3 3KL811 20 3NA7804 4 3TF30 9 3UA5000-1A 1 - 1.6 3UA5000-1A 1 - 1.5
0.75/1 1.9 3KL811 20 3NA7801 6 3TF30 9 3UA5000-1B 1.25 - 2 3UA5000-1C 1.6 - 2.3
1.1/1.5 2.6 3KL811 20 3NA7801 6 3TF30 9 3UA5000-1D 2 - 3.2 3UA5000-1D 2-3
1.5/2 3.7 3KL811 20 3NA7803 10 3TF30 9 3UA5000-1E 2.5 - 4 3UA5000-1E 2.5 - 3.7
2.2/3 4.8 3KL811 20 3NA7805 16 3TF30 9 3UA5000-1F 3.2 - 5 3UA5000-1G 4 - 5.9
3.7/5 7.8 3KL811 20 3NA7807 20 3TF30 9 3UA5000-1H 5-8 3UA5000-1J 6.3 - 9.4
5.5/7.5 11.2 3KL812 32 3NA7810 25 3TF31 12 3UA5000-1K 8 - 12.5 3UA5000-1K 8 - 11.7
7.5/10 16 3KL812 32 3NA7812 32 3TF32 16 3UA5200-2A 10 - 16 3UA5200-2B 12.5 - 18.7
9.3/12.5 19 3KL815 63 3NA7820 50 3TF34 32 3UA5500-2B 12.5 - 20 3UA5500-2C 16 - 23.4
11/15 20.8 3KL815 63 3NA7820 50 3TF34 32 3UA5500-2C 16 - 25 3UA5500-2C 16 - 23.4
15/20 28 3KL815 63 3NA7822 63 3TF34 32 3UA5500-2D 20 - 32 3UA5500-2D 20 - 30
18.5/25 34 3KL815 63 3NA7822 63 3TF35 38 3UA5500-2Q 25 - 36 3UA5500-2R 32 - 37.4
22/30 40 3KL821 100 3NA7824 80 3TF46 45 3UA5800-2FZ1 32 - 50 3UA5800-2FZ1 32 - 47
30/40 53 3KL821 100 3NA7830 100 3TF47 63 3UA5800-2TZ1 40 - 57 3UA5800-2PZ1 50 - 59
37/50 65 3KL822 125 3NA7832 125 3TF477 70 3UA5800-2VZ2 57 - 70 3UA5800-2VZ2 57 - 65.5
45/60 78 3KL822 125 3NA7832 125 3TF49 85 3UA5800-8YZ1 70 - 95 3UA5800-8YZ1 70 - 88.9
55/75 96 3KL823 160 3NA7836 160 3TF50 110 3UA5830-5C 85 - 105 3UA5830-5C 85 - 98.2
75/100 131 3KL831 200 3NA7140 200 3TF51 140 3UA6230-5A 85 - 135 3UA6230-5B 115 - 168
90/125 156 3KL832 250 3NA7144 250 3TF52 170 3UA6230-5B 115 - 180 3UA6230-5B 115 - 168
110/150 189 3KL832 250 3NA7144 250 3TF53 205 3UA6230-5C 160 - 250 3UA6230-5C 160 - 234
132/180 227 3KL833 315 3NA7252 315 3TF54 250 3UA6230-5C 160 - 250 3UA6230-5C 160 - 234
160/215 271 3KL834 400 3NA7260 400 3TF55 300 3UA6230-5D 200 - 320 3UA6230-5D 200 - 299
200/270 339 3KL841 500 3NA7365 500 3TF56 400 3UA6230-5E 250 - 400 3UA6230-5E 250 - 374
250/335 398 3KL841 500 3NA7365 500 3TF57 475 3UA6830-3F 320 - 500 3UA6830-3F 320 - 468

Star-Delta feeder, for Low LCC


SL Motor Motor SDF HRC Fuses Contactor Line/Delta Contactor Star Bi-Relay Bi-Relay Timer
kW/HP Set- Available
IL Iph Type
415V, 3ph, Type Rating Amp Type Amp Type Amp Type (50°C) Range Type (60°C) Set-Range Type
Amp Amp 3NA7
50 Hz Amp Amp
2.2/3 4.8 2.8 3KL811 20 3NA7801 6 3TF30 9 3TF30 9 3UA5000-1D 2-3.2 3UA5000-1D 2-3 3RP15
3.7/5 7.8 4.5 3KL811 20 3NA7803 10 3TF30 9 3TF30 9 3UA5000-1F 3.2-5 3UA5000-1F 3.2-4.7 3RP15
5.5/7.5 11.2 6.5 3KL811 20 3NA7805 16 3TF30 9 3TF30 9 3UA5000-1H 5-8 3UA5000-1H 5-7.5 3RP15
7.5/10 16 9.2 3KL811 20 3NA7807 20 3TF31 12 3TF30 9 3UA5000-1J 6.3-10 3UA5000-1J 6.3-9.4 3RP15
9.3/12.5 19 11 3KL812 32 3NA7810 25 3TF31 12 3TF30 9 3UA5000-1K 8-12.5 3UA5000-1K 8-11.7 3RP15
11/15 20.8 12 3KL812 32 3NA7810 25 3TF31 12 3TF30 9 3UA5000-1K 8-12.5 3UA5000-2S 10-13.6 3RP15
15/20 28 16.2 3KL812 32 3NA7812 32 3TF33 22 3TF32 16 3UA5200-2B 12.5-20 3UA5200-2B 12.5-18.7 3RP15
18.5/25 34 19.7 3KL815 63 3NA7820 50 3TF34 32 3TF34 32 3UA5500-2B 12.5-20 3UA5500-2C 16-23.4 3RP15
22/30 40 23.2 3KL815 63 3NA7820 50 3TF34 32 3TF34 32 3UA5500-2C 16-25 3UA5500-2D 22-30 3RP15
30/40 53 30.6 3KL815 63 3NA7822 63 3TF34 32 3TF34 32 3UA5500-2D 20-32 3UA5500-2Q 25-33.7 3RP15
37/50 65 37.5 3KL821 100 3NA7824 80 3TF35 38 3TF34 32 3UA5500-2R 32-40 3UA5500-8M 36-45 3RP15
45/60 78 45 3KL821 100 3NA7830 100 3TF46 45 3TF34 32 3UA5800-2FZ1 32-50 3UA5800-2FZ1 32-47 3RP15
55/75 96 55.4 3KL821 100 3NA7830 100 3TF47 63 3TF34 32 3UA5800-2TZ1 40-57 3UA5800-2PZ1 50-59 3RP15
75/100 131 75.6 3KL823 160 3NA7836 160 3TF49 85 3TF47 63 3UA5800-8YZ1 70-95 3UA5800-8YZ1 70-88.9 3RP15
90/125 156 90.1 3KL823 160 3NA7836 160 3TF50 110 3TF47 63 3UA5830-5B 70-95 3UA5830-5C 85-98.2 3RP15
110/150 189 109 3KL831 200 3NA7140 200 3TF50 110 3TF50 110 3UA5830-5D 95-120 3UA5830-5D 95-112 3RP15
132/180 227 131.1 3KL832 250 3NA7144 250 3TF51 140 3TF50 110 3UA6230-5B 115-180 3UA6230-5B 115-168 3RP15
160/215 271 156.5 3KL833 315 3NA7252 315 3TF52 170 3TF50 110 3UA6230-5B 115-180 3UA6230-5B 115-168 3RP15
200/270 339 195.7 3KL834 400 3NA7260 400 3TF54 250 3TF52 170 3UA6230-5C 160-250 3UA6230-5C 160-234 3RP15
250/335 398 229.8 3KL841 500 3NA7260 400 3TF54 250 3TF54 250 3UA6230-5C 160-250 3UA6230-5D 200-299 3RP15

27
Your partners
Sales offices:
Ahmedabad Chandigarh Hyderabad Kolkata Nagpur
3rd Floor, Prerna Arbour SCO 188/191, 3rd Floor, Sector-17 C 5-9-19, 4th & 5th Floor 5th Floor, Infinium Digispace 5th Floor, Land Mark Building
Girish Coldrinks Cross Roads Chandigarh - 160 017 Laxmi Narasinh Estate CP - 15, Sector V, Salt Lake Wardha Road, Ramdas Peth
Navrangpura ( : +91 172 4690300 Opp. Secretariat Road Kolkata - 700091 Nagpur - 440 010
Ahmedabad - 380 009 Fax: +91 172 4690399 Saifabad ( : +91 33 30171911 ( : +91 712 3093000
( : +91 79 30927600 Hyderabad - 500 004 Fax: +91 33 30171328 Fax: +91 712 3093111
Chennai
Fax: +91 79 30927699 ( : +91 40 30922500
4th Floor, ETA Mount Central Lucknow Pune
Fax: +91 40 30923145
Baroda Seethakathi Business Centre, Mount Road 28/45, Ashok Marg Tower B/701-705, ICC Trade Tower
Ground Floor, Urja Bhavan Chennai - 600006 Jaipur Opp. Indira Bhawan 403A, Senapati Bapat Road
Opp.Makarpura Railway Station ( : +91 44 30474000 6, Park Street Lucknow - 226001 Pune - 411016
Maneja Fax: +91 44 30474080 Opp. Pink City Petrol Pump ( : +91 522 4031022, 4031000 ( : +91 20 30466000
Vadodara - 390 013 M.I.Road Fax: +91 522 4031019 Fax: +91 20 30466060
Coimbatore
( : +91 265 3957701 Jaipur - 302 006, Rajasthan
1st Floor, “Senthil Towers” Mumbai Vishakhapatnam
Fax: +91 265 3039190 ( : +91 141 5152108
1078, Avinashi Road Business Centre-1 2nd Floor, 30-8-47
Fax: +91 141 2370482
Bengaluru Coimbatore - 641018 Thane Belapur Road Lakshmi Narasimha Towers
1st Floor, Jyoti Mahal ( : +91 422 3076300 Jamshedpur Thane - 400 601 Banu Street, Daba Gardens
No. 49, St. Marks Road Fax: +91 422 3076310 “Roshan Tower” ( : +91 22 39663000 Visakhapatnam - 530 020
Bengaluru - 560 001 Main Road, Bistupur (2nd Floor) Fax: +91 22 39663721 Andhra Pradesh
Gurgaon
( : +91 80 33422000 Jamshedpur - 831001 ( : +91 891 3050200
Plot No -78, Tower –B
Fax: +91 80 33424131 ( : +91 657 6682201 Fax: +91 891 3050222
Jagatjit Industries Building (JIL)
Opposite SBI Academy, Sector-18
Gurgaon - 122015
( : +91 124 2842000, 3810200

Territory managers:
Agra Cochin Jajpur Nashik Rudrapur
31, Maitri Bagh, Dayal Bagh K.G.Oxford Business Centre Kirtan Enclave, Flat No. 316, C Block 1, Nirman Classic Appartment Flat No. 203, Tower Ganges ‘C’
Agra-282005, UP 3A, Shreekandath Rd, Ravipuram Chhordha Chaak, Jajpur Keonjhar Road Thatthe Nagar, Behind HDFC Bank Omaxe Reviera
Mobile: +91 7619047999 Cochin - 682016 Jajpur - 755019 Nashik - 422005 Rudrapur - 263153, Uttarakhand
E-mail: achint.mathur@siemens.com Mobile: +91 9744511109 (Nearest Land Mark - SBI ATM counter) Mobile: +91 9822193204 Mobile: +91 8477022777
Angul E-mail: vinu.pillai@siemens.com Mobile: +91 9937189624 E-mail: shailesh.bakshi@siemens.com E-mail: ashish.bhatt@siemens.com
Plot No. 6097, 1st Floor Dehradun E-mail: probir.mukherjee@siemens.com Nashik Rudrapur
At-Bhandubar (Near RMC Gate) 32, Dhronpuri, Main Lane Jalandhar Flat No. A-4203, Brindavan Gardens Flat No. 104, Tower Rhone ‘C’
Via - Hakimpada. P.O.- Kumanda G.M.S.Road, Deharadun - 248001 H.No. 140, Second Floor, Defence Colony Kedar Nagar, Shramik Nagar Omaxe Reviera Ltd.
Dist. - Angul, Odhisa - 759143 Uttarakhand Jalandhar, Punjab - 144001 Near Satpur MIDC, Nashik 422012 Rudrapur - 263153, Uttarakhand
Mobile: +91 9437114662 Mobile: +91 8650404404 Mobile: +91 8427979870 Mobile: +91 9619620068 Mobile: +91 9621070111
E-mail: sudipta.garnayak@siemens.com E-mail: shashibhushan.prasad@siemens.com E-mail: himanshu.kaushik@siemens.com E-mail: jugal.shah@siemens.com E-mail: abhinav.rastogi@siemens.com
Aurangabad Durg Jammu Neemrana Salem
Flat No. 603, Building A2 Anandvihar Phase-1, Plot No. 18 H.No. # 1A, Sector # 1 Extension Flat No. F 111, Anantraj Apartments Rajagiragham, Lumbini Illam
Disha Sanskruti Silkcity, Paithan Road Borsi South, Durg - 491001, (CG) Friends Colony, Near Marble Market Neemrana Distt. Alwar No. 20, Palaniappa Nagar Hasthampatti
Aurangabad - 431001 (MH) Mobile: +91 9425016197 Trikuta Nagar Extension, Jammu - 190012 Mobile: +91 9650481919 Salem - 636007
Mobile: +91 7720032974 E-mail: jitendra.potdar@siemens.com Mobile: +91 9888851497 E-mail: deepak.beniwal@siemens.com Mobile: +91 8754922245
E-mail: Prashant.Joshi@siemens.com Durgapur E-mail: chander.parkash@siemens.com Panipat E-mail: g.suresh@siemens.com
Belgaum C/o Anjan Sadhu 3/36, A.K. Bithi Jodhpur H.No. 1452, First Floor Sonepat
H.No. 713, Narvekar Lane, Shahpur City Center, P.O. Durgapur - 713216 D-212, Near Sai Baba Mandir, Shankar Nagar Near Police Chownki, HUDA Housing Board H.No. 1103, 1st Floor, Sector-14
Belgaum - 590003, Karnataka Nearest Landmark - Bidisha Residential Pal Road, Jodhpur - 342007 Sector 24, Panipat Sonepat - 131001, Haryana, India
Tel.: +91 0831 2495156 Complex Mobile: +91 7665590333 Mobile: +91 9050068602 Mobile: +91 9855526122
Mobile: +91 9740277991 Mobile: +91 8334977803 E-mail: jain.nitin@siemens.com E-mail: amtinder.singh @siemens.com E-mail: kumar.manish@siemens.com
E-mail: anand.gawade@siemens.com E-mail: saurav.bhowmik@siemens.com Kanpur Patna Sriperumbudur
Belgaum Goa Flat No. 607, Gulmohar Garden Phase I Anubhuti Apartment, Flat No. 201 3/4, Sathyanarayanapuram, Moulivakkam
Flat No. 7, 2nd Floor, Jyotirling Plaza House No S-2, Classque Appartment Shastri Nagar, Kanpur - 208005, UP North Anandpuri, West Boring Canal Road Porur, Chennai - 600 116
Congress Road, Thilakwadi Porvorim, Goa - 403501 Mobile: +91 9839102434 Patna - 800001 Mobile: +91 9884102638
Belgaum - 590011, Karnataka Mobile: +91 7722008113 E-mail: shagun.gupta@siemens.com Mobile: +91 9771414108 E-mail: venkatesh.janakiraman@siemens.com
Mobile: +91 7259400100 E-mail: jithin.jacob@siemens.com Khopoli E-mail: vikash.prasad@siemens.com Surat
E-mail: prathish.t_m@siemens.com Gulbarga Flat A 14, Dutta Krupa Housing Society Pondicherry 3/A, Navrachana Society, Opp. D.K.Park
Bharuch Flat No.13, 3rd Floor, Shubha Residence Upper Khopoli, Near Datta Mandir No. 31, 4th Cross Street, Anna Nagar Bhatar Road, Surat - 395001
Gold B, 804, Samruddhi Residency Deshmukh Layout, Drajmapur, Kalaburagi Khopoli - 410203 Pondicherry - 605005 Mobile: +91 9879510191
Opp. Zadeshwar Bus Stop, Zadeshwar Road Gulbarga District - 585103 Mobile: +91 9930171377 Mobile: +91 9840143536 E-mail: mitul.kapadia@siemens.com
Bharuch - 392011 Karnataka E-mail: vilas.bhosale@siemens.com E-mail: lakshmanan.s@siemens.com Surat
Mobile: +91 9429037805 Mobile: +91 7259661717 Kolhapur Raipur A 604, Stuti Universal, Green City Road
E-mail: kalpeshkumar.darji@siemens.com E-mail: anirudh.ganta@siemens.com RS No. 84-1, Pinac Prasad, Flat No. A-35 103 Risabh Regency Pal-Adajan, Surat - 395009, Gujarat
Bhilai Guwahati New Palace Road, Kolhapur - 416006 Near Shri Medishine Hospital Mobile: +91 9712445504
Flat No. M-203, Rishabh City Prime House No. 20, Ushanagar Mobile: +91 9850836839 New Rajendra Nagar E-mail: harshwardhan.mishra@siemens.com
Potia kala, Durg - 490 001 (CG) Dispur Supermarket, Guwahati E-mail: vinay.todkar@siemens.com Raipur (C G) - 492006 Trichy
Mobile: +91 7869922211 Assam - 781006 Kota Mobile: +91 9425601849 1/1209-B, 6th Cross Street, West Extension
E-mail: pravin.deshbhratar@siemens.com Mobile: +91 9864110684 406, Manglayatan Appartments E-mail: raghuraj.bisen@siemens.com Vasan Nagar, Rettai Vaikkal, Vayalur Road
Bhopal E-mail: biplab.datta@siemens.com Near Jain Mandir, Bhimganj Mandi Rajahmundry Tirchy - 602102
Flat No. 104, Sagar Home Phase-2 Hospet Kota - 324002 Plot No. 401, SVR Residency Mobile: +91 9176609375
Sarvadharma Society, Sector A Ramanand Residency, Flat No. 204 Mobile: +91 9828419111 Door No. 77-2-29/3, Gandhipuram - 3 E-mail: Muthu.kumar@siemens.com
Nayapura Road, Bhopal - 462042 1st Main, Nehru Co-op Colony E-mail: avinash.mathur@siemens.com Rajahmundry Dist. East Godavari - 533106 Trivandrum
Madhya Pradesh Hospet - 583203, Ludhiana Andhra Pradesh No.147-A, Vishnu Bhawan,
Mobile: +91 9977228084 Karnataka H.No. 6920, Street No. 1, Jaswant Nagar Mobile: +91 9948664228 Swathy Nagar (SNRA-4), Kazhakuttom,
E-mail: prajwal.khapekar@siemens.com Mobile: +91 9901400227 Near Samrala Chowk, Ludhiana - 141008 E-mail: naga.ganesna@siemens.com Trivandrum - 685 582
Bhubaneswar E-mail: roy.sanjib@siemens.com Mobile: +91 9876047929 Rajkot Mobile: +91 9947957839
Plot No. 1597, Infront of Fishery Lane Hospet E-mail: sunil.singla@siemens.com “Vrujraj”, Chandanpark Society E-mail: nobin.babu@siemens.com
Chintamaniswar, Bhubaneswar - 751006 # 727, Lakshmi Narasimha Nilaya Ludhiana Opp. Gyanganga Vidhyapith, Nr.Raiya Circle Udaipur
Odisha Near Surbhi Kalyana Mantapa, Amaravathi 149/64, J Block B.R.S.Nagar, Ludhiana (PB) Rajkot - 360005, Gujarat A-39, New Ahinsapuri, Fatehpura
Mobile: +91 9937063598 Hospet - 583203 Mobile: +91 9815434499 Mobile: +91 9825021026 Udaipur (Rajasthan) - 313004, India
E-mail: sumit.sengupta@siemens.com Mobile: +91 9741114877 E-mail: bhatia.sandeep@siemens.com E-mail: hiren.raithatha@siemens.com Mobile: +91 9983691888
Bhubaneswar E-mail: naveen.sn@siemens.com Ranchi E-mail: anurag.shah@siemens.com
Ludhiana
Archid Royal Apartment, Flat No. 302 Hosur R-115 Near DAV School Sarabha Nagar Flat No. A-101, 1st Floor Ujjain
Nageswar Tangi, Bhubaneswar - 751002 # B2, “Sunshine” 1st Floor Extension Phase - 2 Pakhowal Road Sundaram Apartment, Kilburn Colony Amit Singh Bhadauria, Tirupati Hights
Odisha Sipcot Housing Colony, Dharga Ludhiana, Punjab Hinoo, Ranchi, Jharkhand - 834002 B-block, Flat No. 206, Nana Kheda
Mobile: +91 9163442180 Hosur - 635126, Mobile: +91 9888484066 Mobile: +91 8294052647 Dipti Parisar, Ujjain-Indore Road
E-mail: pm.barik@siemens.com Tamilnadu E-mail: padam.sharma@siemens.com E-mail: shyamal.bhattacharyya@siemens.com Ujjain - 456010 (MP)
Boisar Mobile: +91 9880213880 Renukoot Mobile: +91 8889911401
Madurai
Flat No. 101, A Wing E-mail: kamalanaban.tv@siemens.com Raj Bhawan (Near Khatu Shyam Mandir) E-mail: Bhadauria.amit@siemens.com
Anirudh Block F-Top 3, Vasudhara Apt.
Mahavir Shrishti Apartments Hubli 84, TPK Main Road, Andalpuram Awadh Colony, Murdhwa, Renukoot Vapi
Near Madhur Hotel, Navapur Road # 21, Sri Mallikarjuna Nilaya, 1st Floor Madurai - 625003, Tamil Nadu Sonebhadra - 231217 Flat No. 401, A Wing, Madhav Gems
Boisar, Thane (W) - 401506 Somanagowdara Layout, Bengeri Extension Mobile: +91 9894617776 Mobile: +91 9889384222 Nutannagar, Valsad Road, Vapi (East)
Mobile: +91 9819231892 Hubli - 580023, E-mail: sivaprakasam.r@siemens.com E-mail: umesh.pandey@siemens.com Valsad Dist, Vapi - 396191
E-mail: debashis.biswas@siemens.com Karnataka Rourkela Mobile: +91 9687668690
Meerut
Cochin Mobile: +91 9880003724 D/6, Gafoor Colony, 2nd Floor E-mail: pandey.abhishek@siemens.com
E-205, Ansal Courtyard, Roorkee Bypass
K.G.Oxford Business Centre E-mail: kr.purushottam@siemens.com Near LIC Office, Udit Nagar
Modipuram, Meerut - 250110, UP Vapi
3A, Shreekandath Rd, Ravipuram Indore Mobile: +91 9720999887 Rourkela - 769012, Odisha Shubham Tower No.3, ‘C’ Wing
Cochin - 682016 Govind Dham, 13 Ahilyapuri E-mail: singh.vineet@siemens.com Mobile: +91 9776967773 Flat No.1008, Chala, Vapi Daman Road, Vapi
Tel.: +91 4028611/22 Near Residency Club E-mail: prakhar.chaturvedi@siemens.com Mobile: +91 9825147957
Meerut
Mobile: +91 9846006580 Indore - 452001 (MP) Rourkela E-mail: s.anand@siemens.com
C-904, Ansal Courtyard, Roorkee Bypass
E-mail: girish.v_nair@siemens.com Mobile: +91 9977236899 N/6, Flat No. 3A, Civil Township
Modipuram, Meerut - 250110, U P Vijayawada
Cochin E-mail: raghvendra.bhadouria@siemens.com Opposite Hi-tech Medical College & Hospital
Mobile: +91 9999702981 Laxmi Nivas, 1st Floor, Flat No. FF2
K.G.Oxford Business Centre Indore E-mail: shailendra.kumar@siemens.com Rourkela, Odisha - 769004 44/3 & 44/2, Plot No. 08
3A, Shreekandath Rd, Ravipuram C/o Dr. Mahesh Malviya, House No. 336 Mobile: +91 9937972407 Sundarayya Nagar, Payakapuram
Mysore
Cochin - 682016 Scheme No. 114, Part 2 E-mail: shouvik.mitra@siemens.com Vijayawada - 520015, Andhra Pradesh
#43, Ground Floor, 8th Cross
Mobile: +91 9526065551 Indore - 452010, M.P. Mobile: +91 9642351144
3rd Main, 1st Stage, “C” Block, J .P. Nagar
E-mail: abhishek.tyagi@siemens.com Mobile: +91 9713013050 E-mail: venkateswar.d@siemens.com
Mysore - 570008
E-mail: rohit.seth@siemens.com
Mobile: +91 9900855779
E-mail: niranjan.kv@siemens.com

Siemens Ltd. Order No.: 106616362


Digital Factory DF-CP-LP-CC06972015
Control Products
R&D Technology Centre
Kalwa Works, Thane Belapur Road
Thane - 400 601
Product upgradation is a continuous
Fax: +91 22 33265627 process. Hence, data in this catalog is
E-mail: lvsgr-mktg.india@siemens.com Customer Care Toll free no.
subject to change without prior notice. For
1800 209 0987 the latest information, please get in touch
www.siemens.co.in Email: ics.india@siemens.com with our Sales Offices.

You might also like