Sans 10400 Disabled
Sans 10400 Disabled
Sans 10400 Disabled
pub
li
cofS
out
hAf
ri
ca
≠ EDI
CTOFGOVERNMENT±
Inor
dertopromotepubl
iceduca
ti
onandpubl
ics
afet
y,equ
aljus
ti
cefora
ll
,
abet
te
ri n
for
me dcit
iz
enry,th
eruleo
flaw,worl
dtra
deandworldpea
ce,
t
hisl
egaldoc
ume n
tisherebymadeav
ail
abl
eonan onc
ommerci
albas
is
,asit
i
stheri
ghtofallhumanstoknowandspe
akthela
wsthatgov
ernthe
m.
Table of changes
Change No. Date Scope
Acknowledgement
The SABS Standards Division wishes to acknowledge the work of the South African Institute of
Architects and the South African Institution of Civil Engineering in updating this document.
Foreword
This South African standard was approved by National Committee SABS SC 59Q, Construction
standards – Facilities for persons with disabilities in buildings and the built environment, in accordance
with procedures of the SABS Standards Division, in compliance with annex 3 of the WTO/TBT
agreement.
This document supersedes the corresponding parts of SABS 0400:1990 (first revision) and
SABS 0246:1993 (edition 1).
Compliance with the requirements of this document will be deemed to be compliance with the
requirements of part S of the National Building Regulations, issued in terms of the National Building
Regulations and Building Standards Act, 1977 (Act No. 103 of 1977).
SANS 10400 consists of the following parts, under the general title The application of the National
Building Regulations:
Part C: Dimensions.
Part G: Excavations.
Part H: Foundations.
Part J: Floors.
Part K: Walls.
Part L: Roofs.
Part M: Stairways.
Part N: Glazing.
SANS 10400-S:2011
Edition 3
Foreword (concluded)
Part O: Lighting and ventilation.
Part P: Drainage.
This document should be read in conjunction with SANS 10400-A. The requirements of this document
form part of SANS 10400-D, SANS 10400-M and SANS 10400-T.
1
SANS 10400-S:2011
Edition 3
Contents
Page
Acknowledgement
Foreword
1 Scope ..................................................................................................................................... 3
3 Definitions .............................................................................................................................. 4
4 Requirements ......................................................................................................................... 8
Annex B (informative) Access needs of persons with disabilities in the context of the
South African legislative framework ...................................................... 27
Annex D (informative) Notes on the design and layout of toilet facilities for
persons with disabilities ......................................................................... 38
Bibliography .............................................................................................................................. 46
2
SANS 10400-S:2011
Edition 3
Part S:
Facilities for persons with disabilities
1 Scope
This part of SANS 10400 provides deemed-to-satisfy requirements for compliance with part S (Facilities
for Persons with Disabilities) of the National Building Regulations.
NOTE 1 Part S of the National Building Regulations, issued in terms of the National Building Regulations and
Building Standards Act, 1977 (Act No. 103 of 1977), is reproduced in annex A.
NOTE 2 Compliance with the requirements of this part of SANS 10400 does not necessarily ensure compliance
with all legislative provisions (see annexes B and C). Other standards may be applicable for dealing with specific
matters that are not covered by the National Building Regulations, e.g. ISO 7193 should be used to ensure that
workbenches etc. are accessible to wheelchair users.
2 Normative references
The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced
document (including any amendments) applies. Information on currently valid national and international
standards can be obtained from the SABS Standards Division.
SANS 1186-1, Symbolic safety signs – Part 1: Standard signs and general requirements.
SANS 10389-1, Exterior lighting – Part 1: Artificial lighting of exterior areas for work and safety.
SANS 10400-A, The application of the National Building Regulations – Part A: General principles and
requirements.
SANS 10400-D, The application of the National Building Regulations – Part D: Public safety.
SANS 10400-M, The application of the National Building Regulations – Part M: Stairways.
SANS 10400-O, The application of the National Building Regulations – Part O: Lighting and ventilation.
SANS 10400-P, The application of the National Building Regulations – Part P: Drainage.
SANS 10400-T, The application of the National Building Regulations – Part T: Fire protection.
3
SANS 10400-S:2011
Edition 3
3 Definitions
For the purposes of this document, the definitions given in SANS 10400-A (some of which are repeated
for convenience) and the following apply.
3.1
access
approach, entry or exit
3.2
accessible
characteristic of a building, that can be reached, entered and used
NOTE Accessibility is evaluated in terms of the safe, comfortable and convenient use of the site, building or facility
by persons with disabilities.
3.3
accessible building
building that complies with the requirements of this part of SANS 10400
3.4
accessible route
walking space that complies with the requirements of this part of SANS 10400
3.5
adequate
adequate
b) in relation to any document issued by the council, in the opinion of the council
3.6
approved
approved
b) by the Review Board on appeal to the Review Board in terms of the Act
3.7
circulation space
unobstructed area, for a minimum height of 2,1 m above finished floor level, within and around buildings,
elements, fixtures and fittings required for movement into and within buildings
3.8
clear opening width
clear open space of an open door through which the user of a building passes
NOTE Clear opening width is not the same as the door width, as it also accounts for the thickness of the door, and
any obstructions caused by door furniture on the door, or obstructions such as doorstops fixed to the floor or walls.
3.9
competent person
as defined in SANS 10400-A
4
SANS 10400-S:2011
Edition 3
3.10
competent person (environmental access)
person who is
a) registered in terms of the Architectural Profession Act, 2000 (Act No. 44 of 2000), as either a
Professional Architect, Professional Senior Architectural Technologist or a Professional Architectural
Technologist, and has suitable contextual knowledge and experience to undertake a rational design
or rational assessment in terms of the requirements of part S of the Regulations; or
3.11
deemed-to-satisfy requirement
non-mandatory requirement, the compliance with which ensures compliance with a functional regulation
3.12
easy-to-use
descriptive of a fixture or fitting that has been designed and fitted in such a way that persons with
disabilities are able to use it safely, comfortably and conveniently, both in terms of the mechanism used
for its operation and the force required to operate it
3.13
emergency route
that part of an escape route which provides fire protection to the occupants of any building and which
leads to an escape door
3.14
entrance
any access point to a building or portion of a building or facility, used for the purposes of entering
NOTE An entrance includes the approach walk, the vertical access leading to the entrance platform, the entrance
platform itself, vestibule if provided, the entry door or gate, and the hardware of the entry door or gate.
3.15
escape door
door in an escape route which, at ground level, leads directly to a street or public place or to any
approved open space which leads to a street or public place
3.16
escape route
entire path of travel for all persons, including persons with disabilities, from the furthest point in any
storey in a building to the nearest escape door and may include an emergency route
3.17
exit door
door that is a component of an escape route from any room
3.18
flush finish
finishing of two adjacent surfaces in such a way that they provide no vertical or horizontal gap, gradient
or camber that might affect the safe, comfortable and convenient passage of persons with disabilities
5
SANS 10400-S:2011
Edition 3
3.19
functional regulation
regulation that sets out in qualitative terms what is required of a building or building element or building
component in respect of a particular characteristic, without specifying the method of construction,
dimensions or materials to be used
3.20
grab rail
rail used as a support to transfer a person on or off a toilet, or to assist with other functions
3.21
handrail
rail used in circulation areas, such as corridors, passageways, ramps or stairways, to assist continuous
and safe movement
3.22
impaired
lower than generally accepted optimum performance in a human ability, which might be a temporary or
permanent condition
3.23
impairment
indicative of any one impaired ability
3.24
kerb cut
link between a road traffic surface and an elevated or lowered pedestrian pavement
3.25
landing
platform between two consecutive flights of a stairway or ramp
3.26
light reflectance value
LRV
measurement, using a spectrophotometer, of the light reflected from a surface in standard conditions
NOTE It is expressed on a scale of 0 to 100, with black being about 5 and white about 90.
3.27
main entrance
entrance that leads directly to
a) a reception area or point that provides information about the building or services within it, or
3.28
means of access
means of entering a building, site of buildings or building complex, and safe egress from the building,
site of buildings or building complex, including the use of all facilities within and around the building, site
of buildings or building complex
NOTE The means of access relates to the safety, comfortable and convenient use of both the building, site of
buildings or building complex and the facilities within it for persons with disabilities.
6
SANS 10400-S:2011
Edition 3
3.29
obstruction
any of the following:
a) anything impeding or preventing passage or progress in relation to a building or facility, which denies
or removes from persons with disabilities, any supporting or enabling facility for their functioning
within the building or facility; or
b) obstacles that unfairly limit or restrict persons with disabilities from enjoying the opportunities
provided within a building or facility on equal terms with persons without disabilities
NOTE The failure to take steps to reasonably accommodate the needs of persons with disabilities within the
building or facility can also be seen as a type of obstruction.
3.30
occupancy
particular use or type of use to which a building or portion thereof is normally put or intended to be put
NOTE Regulation A20 (see SANS 10400-A) classifies and designates occupancies.
3.31
path of travel
circulation route or circulation space normally used by persons using the site, building or facility,
including all external and internal routes and spaces in common usage, and the entrances and exits
within these routes and spaces
3.32
person with disabilities
person who has long-term physical, mental, intellectual or sensory impairments which, in interaction with
various barriers, might hinder his full and effective participation in society on an equal basis with others
3.33
ramp
internal or external walkway with a slope between 1:20 and 1:12, in the direction of travel
3.34
rational assessment
assessment by a competent person of the adequacy of the performance of a solution in relation to
requirements including as necessary, a process of reasoning, calculation and consideration of accepted
analytical principles, based on a combination of deductions from available information, research and
data, appropriate testing and service experience
3.35
rational design
design by a competent person involving a process of reasoning and calculation and which may include a
design based on the use of a standard or other suitable document
3.36
sanitary fixture
receptacle to which water is permanently supplied, and from which waste water or soil water is
discharged
3.37
secondary entrance
entrance that is not the main entrance, and that leads directly to
a) a reception area or point that provides information about the building or services within it; or
7
SANS 10400-S:2011
Edition 3
3.38
site
erf, lot, plot, stand or other piece of land on which a building has been, is being or is to be erected
3.39
space
definable area, such as a room, toilet room, hall, assembly area, entrance, storage room, alcove,
courtyard, or lobby
3.40
storey
that part of a building which is situated between the top of any floor and the top of the floor next above it
or, if there is no floor above it, that portion between such floor and the ceiling above it (any open work
floor, catwalk or gallery being taken to be part of the storey in which it is situated); and in relation to a
building
a) the ground storey is taken as the storey in which there is situated an entrance to the building from the
level of the adjoining ground or, if there is more than one such storey, the lower or lowest of these,
b) a basement is taken to be any part of the building which is below the level of the ground storey,
c) an upper storey is taken to be any storey of the building which is above the level of the ground storey,
and
d) the height expressed in storeys is taken to be that number of storeys which includes all storeys other
than a basement
3.41
suitable
capable of fulfilling or having fulfilled the intended function, or fit for its intended purpose
3.42
tactile
that can be perceived by using the sense of touch
3.43
transfer space
space required by a wheelchair user to transfer to or from a vehicle, toilet or seat
3.44
turning space
circulation space in which a wheelchair can turn through 360°
3.45
wheelchair-accessible toilet
toilet designed to include use by wheelchair users
4 Requirements
NOTE The requirements of this part of SANS 10400 form part of SANS 10400-D, SANS 10400-M and
SANS 10400-T.
4.1 General
The functional regulation S2 contained in part S of the National Building Regulations (see annex A) shall
be deemed to be satisfied where
8
SANS 10400-S:2011
Edition 3
b) any entrance or route used as part of an escape route in order to comply with the requirements of
part T of the National Building Regulations is also accessible to persons with disabilities.
NOTE Regulation S1 identifies the buildings to which Regulation S2 applies (see annex A).
4.2 Signage
4.2.1 Facilities that are included in a building specifically for use by persons with disabilities, such as
wheelchair-accessible parking spaces, wheelchair-accessible toilets, and platform or stair lifts, shall be
indicated by the international symbol for access (see figure 1) and shall comply with 4.2.2 and 4.2.4. The
international symbol shall be exhibited
a) at the main entrance of, and at any other suitable position in, a building, and
b) in suitable positions to indicate to persons with disabilities the route to the exit of such facilities.
4.2.2 The sign used to indicate facilities provided for persons with disabilities shall be the SANS 1186-1
type designation GA 22 (allocated to or accessible to wheelchairs) sign. Such signage shall comply with
the requirements of SANS 1186-1 and shall have a symbol height of not less than 110 mm.
4.2.3 Facilities that are not in accordance with the requirements of this part of SANS 10400 shall not
bear the international symbol.
NOTE 1 The symbol is the property of the International Standards Office and its use can only be sanctioned where
the minimum requirements of the National Building Regulations have been complied with.
NOTE 2 Signs should be in clear, visible and tactile format to ensure that persons with visual impairments are also
fully informed. In buildings where persons with visual impairments work or live, evacuation instructions in large print
and Braille should be provided, so that persons with visual impairments can familiarize themselves with escape
routes.
4.2.4 Clear legible signs shall indicate the direction and name of an accessible facility and shall
incorporate the international symbol. The height of the lettering shall not be less than 50 mm.
Where the viewing distance is greater than 10 m, the height of the lettering shall be increased
accordingly (see table 1).
To enable persons with impaired vision to read location signs adjacent to doors or directional signs on
walls, the signs should be placed at a height of between 1,4 m and 1,7 m above finished floor level.
NOTE Raised letters and symbols, in contrasting light and dark colours, on identification or location signs assist
those who are blind or have impaired vision.
9
SANS 10400-S:2011
Edition 3
All internal signage to indicate escape routes in case of total blackout shall comply with the requirements
of SANS 10400-T.
4.2.5 For demarcating parking areas for wheelchair users, signs should be not less than 2,0 m vertically
above driveway level, so that the sign can be seen whilst driving a car.
4.2.6 Where electronic aids are installed to assist persons with hearing loss, a suitable sign shall be
displayed to indicate such facilities.
4.2.7 Any mark or sign shall comply with the relevant requirements of SANS 1186-1.
4.3 Parking
4.3.1 For employee parking, at least one parking space shall be accessible for persons with disabilities.
4.3.2 In addition to the requirement of 4.3.1, where provision has been made within a building, or on
the site on which such building is erected, for the parking of more than 50 motor vehicles,
a) at least one parking space per 25 parking spaces (or part thereof) and at least 20 % of the parking
spaces at rehabilitation and medical facilities shall be provided for parking of vehicles used by
persons with disabilities;
b) the parking spaces provided for vehicles used by persons with disabilities shall be of a suitable
length, shall be at least of the dimensions shown in figure 2, and shall be situated on and accessed
from a surface that is not steeper than 1:50;
c) any parking space provided for vehicles used by persons with disabilities shall be located within 50 m
of an accessible entrance;
d) any parking space provided for vehicles used by persons with disabilities shall be clearly demarcated
as being intended for the use of persons with disabilities only;
e) entry and routing to any parking space designated for persons with disabilities shall be provided with
a clear height of at least 2,4 m and shall allow for the entry of vehicles suitable for use by wheelchair
users, particularly those that have a hoist to carry the wheelchair on top of the car.
4.3.3 Parking spaces shall be identified by a vertical sign incorporating the international symbol for
access by persons with disabilities, in accordance with 4.2. The international symbol shall also be clearly
painted on the road surface (see figure 2) and it shall be 1 000 mm × 1 000 mm.
NOTE Road signs for persons with disabilities should be provided in accordance with the latest edition of The
Southern African Development Community Road Traffic Signs Manual (SADC RTSM) published by the Department
of Transport.
10
SANS 10400-S:2011
Edition 3
Dimensions in millimetres
a) Full width for wheelchair needed b) Marked out shared space between
adjacent to standard bay two standard bays
4.4.1 General
4.4.1.1 An accessible route shall form part of an external and internal circulation route.
NOTE The space allowances of this part of SANS 10400 should accommodate the use of self-propelled
wheelchairs. The minimum dimensions might need to be increased to accommodate the full range of different types
of wheelchair.
4.4.1.2 At least one accessible route shall be provided within the boundary of the site from all public
transportation stops, accessible parking spaces, passenger loading zones and public streets and
pavements to the accessible building entrance which they serve and the facilities inside the building.
4.4.1.3 There shall be a means of access suitable for use by persons with disabilities from the outside
of the building to the ground storey.
4.4.1.4 The clear width of the walking surfaces shall not be less than 900 mm (such as between
bollards in parking areas, or between planters and seating) and shall not be reduced by protruding
objects. If the clear width is less than 1,5 m, an accessible route shall be provided with passing spaces
of 1,5 m × 1,5 m (minimum) at intervals not exceeding 5,0 m, or an intersection of two walking surfaces
which provide a T-shaped space.
4.4.1.5 Each accessible entrance to a building shall have at least one door or doorway in accordance
with the requirements of 4.6.1.
4.4.1.6 Revolving doors, revolving gates and turnstiles shall not form part of an accessible route.
4.4.1.7 Pause areas, with suitable seating, shall be provided adjacent to an accessible route at intervals
that do not exceed 25 m.
11
SANS 10400-S:2011
Edition 3
4.4.2.1 The turning space allowance, e.g. for a wheelchair, guide dog or person on crutches, shall be a
minimum of 1,5 m in diameter, inclusive of any toe and knee clearances.
4.4.2.2 Doors shall not be permitted to swing into the turning spaces.
4.4.3.1 Protruding objects shall not reduce the clear width required for accessible routes.
4.4.3.2 Hanging signs, lights, awnings and objects that protrude into circulation spaces shall have a
clearance of at least 2 m above the trafficable surface.
4.4.3.3 Windows and doors shall not open across a walkway, corridor, stair or ramp. Doorstops shall be
so positioned that any door will open to its maximum, and that they will not create a hazard.
4.4.3.4 Wall-mounted fire extinguishers, hose reels, telephones, litter bins and any other wall-mounted
fittings shall
c) be accompanied by a feature that warns of the presence of the potential hazard and that is possible
to detect by a person using a white cane or stick.
4.4.3.5 A dished channel shall not be constructed within the boundaries of a path.
4.4.3.6 A drainage grating that is within the boundaries of a path shall be set flush with the surface of
the path. Such grating shall be placed so that its longitudinal elements are perpendicular to the main
walking direction, and the gap between them shall not exceed 13 mm.
4.4.3.7 Where identified parking for persons with disabilities is provided, a kerb cut that has a slip-
resistant finish and gradient that does not exceed 1:12 shall be provided immediately adjacent to the bay
(see figure 3).
NOTE 1 Kerb cuts should be provided where required, and in conjunction with pedestrian crossings, taxi and bus
ranks and parking garages.
NOTE 2 The recommended surface between a pavement and roadway is a ramp fitted with tactile guidance
surface indicators. This provides a safe and trafficable surface for wheelchair users, and a detectable surface to
indicate to persons with visual impairments that they are leaving a pedestrian footpath and entering a traffic
roadway.
12
SANS 10400-S:2011
Edition 3
Dimension “x” equals width of crossing, unless the kerb cut leads from a parking bay, in which case x shall not
be less than 1 400 mm.
A buffer of 300 mm is provided (in accordance with SANS 784) from the edge of the roadway.
13
SANS 10400-S:2011
Edition 3
4.5.2 Carpet, carpet tiles or other floor finishes shall be securely attached and level across all types of
pile. Pile height of carpets shall not exceed 3 mm.
4.5.3 Openings in the floor finish or ground surface shall not exceed 13 mm in diameter and, where the
opening is elongated, the long dimension shall be placed perpendicular to the dominant direction of
travel.
4.5.4 The vertical change in level between two floor surfaces, or at thresholds, shall have a flush finish
and shall not exceed 5 mm in height.
4.5.5 Where a surface is cambered for drainage purposes, the camber shall not exceed 1:50 (see
figure 4).
4.5.6 Cobbles (whether fixed or loose), gravel sand and other raised or loose finishes shall not form
part of an accessible route.
4.6.1.1 Doorways shall allow free access for wheelchair users. The clear opening shall be at least
750 mm when approached along a line that is perpendicular to the opening, as shown in figure 5.
NOTE It is recommended that, where possible, the clear opening width should be 800 mm.
14
SANS 10400-S:2011
Edition 3
4.6.1.2 Where a two-leaf door is used, the clear opening provided by the leading leaf shall be at least
750 mm, as shown in figure 6, when approached along a line perpendicular to the opening.
4.6.1.3 Minimum access dimensions to enable wheelchair users to make 90° turns, shall be as shown
in figure 7.
4.6.1.4 Where a person in a wheelchair is required to open a door towards the wheelchair, a nib of at
least 450 mm shall be provided at the handle side of the door, as shown in figure 8.
Dimensions in millimetres
15
SANS 10400-S:2011
Edition 3
4.6.1.5 The minimum distance between doors shall be as shown in figures 9 and 10.
4.6.1.6 Sliding doors may be installed in places where a hinged door would hinder circulation or
manoeuvrability.
4.6.1.7 Where revolving doors, turnstiles or other barriers are installed, an alternative means of access
shall be installed.
NOTE 1 Doors are a hindrance and their use should be avoided. Where doors cannot be avoided, for example, in
a route used for emergency egress, doors should be held open by a mechanism that is safe, comfortable and
convenient for persons with disabilities to operate, such as magnetic closers.
NOTE 2 Frequently used doors, such as main entrance self-closing doors, should preferably open automatically and
be equipped with a fail-safe system that enables the door to open under emergency conditions
Dimensions in millimetres
Dimensions in millimetres
4.6.2.1 A handle fitted to a door leaf of a door in an emergency route or in a feeder route or in any
compartment containing toilet facilities for use by persons with disabilities, shall be of the lever type, with
a lever at least 150 mm long, and shall be installed at a height that does not exceed 1,0 m above floor
level.
16
SANS 10400-S:2011
Edition 3
4.6.2.2 Round door knobs do not provide an adequate grip for persons with impaired dexterity and shall
be avoided.
4.6.2.5 Door furniture with sharp protruding edges is hazardous and shall not be used.
4.7.1 In trafficable areas for public use, any changes in level shall comply with the requirements of
SANS 10400-D, and with the requirements given in 4.7.2 and 4.7.3.
4.7.2 A raised kerb, not less than 75 mm high, or a skirting rail not more than 300 mm high, measured
vertically above the surface, shall be provided on exposed sides of any ramp, stairway, balcony or any
similar area where a change in level occurs.
4.7.3 Where a change in level of more than 600 mm occurs, a handrail shall also be provided.
4.8 Ramps
NOTE 1 Ramps might be required for use by persons without disabilities, for example, persons pushing trolleys
who require ramps as an alternative to stepped access.
NOTE 2 Ramps should only be provided where level access cannot be achieved. Where a ramp is provided,
stepped access should normally accompany it for persons with ambulant disabilities who find ramps difficult to use.
4.8.1 Any ramp or series of ramps shall provide a safe, comfortable and convenient route for
wheelchair users.
4.8.2 Any ramp provided in terms of this part of SANS 10400 shall
a) have a gradient, measured along the centre line, that is not steeper than 1:12 ;
d) have a landing at the top and bottom of each ramp of not less than 1,2 m in length (clear of any door
swing) and of width not less than that of the ramp;
e) comply with the requirements between landings as given in table 2 and figure 11;
f) have a handrail on both sides of the ramp or, where the width is greater than 2,4 m, a central handrail
in accordance with the requirements of 4.10 where the gradient is steeper than 1:15;
g) where ramps in the same direction are used for a vertical rise of more than 600 mm, be staggered by
the width of the ramp, in order to prevent a long straight line of ramps (see also 4.8.2(d)).
NOTE Where the total rise contemplated for a series of ramps is greater than 2 m, consideration should be given
to alternative means of vertical circulation.
17
SANS 10400-S:2011
Edition 3
1 2 3
Maximum Maximum ramp
vertical length
Gradient
rise between landings
mm m
1:12 500 6
1:15 665 10
1:20 750 15
NOTE For goings between 6 m and 15 m, it is permissible to interpolate between the maximum gradients,
e.g. 1:16 for an 11 m going.
4.8.3 No door leaf or window shall open onto a ramp or landing (see also 4.8.2(d)).
4.8.4 The camber or banking on walkways and ramps shall not exceed 1:50, as shown in figure 4.
4.8.5 At any point where the clear height of the area below the soffit is less than 2,1 m, and it is not
enclosed, the means of limiting inadvertent access to such area shall be indicated.
18
SANS 10400-S:2011
Edition 3
4.9 Stairways
4.9.1 Stairways shall comply with the requirements of SANS 10400-M, SANS 10400-T and the
following requirements:
a) the width of any stairway, measured to an enclosing wall or balustrade, shall be at least 900 mm;
b) a landing that serves two flights of stairs in the same straight line shall be of length at least
1 100 mm;
c) the rise of each tread step shall be of the same height and shall not exceed 170 mm;
e) a stairway shall be provided with handrails on both sides of the stairway in accordance with the
requirements of 4.10;
f) The maximum height allowed in a flight of stairs, between landings, shall not exceed 1,530 m;
g) The stairway shall not include any winders (as defined in SANS 10400-M);
4.9.2 Nosings shall effectively contrast with their immediate surroundings. The minimum dimensions of
each nosing shall be 40 mm × 40 mm.
NOTE Further guidance on contrast and methods of measurement is provided in SANS 784.
4.9.3 Outdoor stairs and outdoor approaches to stairs shall be so designed that water will not
accumulate on walking surfaces.
4.9.4 Tactile guidance, where provided, shall be in accordance with the relevant provisions of
SANS 784.
4.10 Handrails
The design and construction of handrails shall be in accordance with the following:
a) handrails shall have an elliptical gripping surface profile that is approximately 50 mm wide and 40 mm
deep, or a circular profile of diameter not less than 35 mm and not more than 50 mm;
b) the height to the top of a handrail from the nosing of the tread of the stairs or from the surfaces of
a ramp shall be in the range 900 mm to 1 000 mm and shall remain consistent along the length;
d) the surface of the handrail and wall, or any other surface adjacent to them, shall be free of any sharp
or abrasive elements;
e) the clear width between a handrail and an adjacent wall shall be at least 60 mm;
f) handrails shall extend 300 mm horizontally beyond the top and bottom of the ramp or stairway (see
figure 12 and shall return to the supporting structure or shall be finished with a positive return, and the
minimum dimensions for landings on escape routes as required in SANS 10400-T shall be
maintained;
g) handrails shall be continuous between landings where this does not create a hazard;
19
SANS 10400-S:2011
Edition 3
h) handrails shall be supported centrally from below with not less than 50 mm between the underside of
the handrail and the top of the support;
i) where a stairway is wider than 2,4 m, a handrail shall be provided at no more than 2,4 m intervals.
NOTE Handrails that extend at the top and bottom of a stairway are a tactile aid for persons with visual
impairments, and a balancing aid for ambulant persons with disabilities.
Dimensions in millimetres
a) Elevation of handrails
4.11 Lifts
a) passenger lifts serve all the storeys of the building that can be accessed by the stairway, and
b) through-floor lifts may be used to serve a partial storey (see SANS 10400-A) of area greater than
100 m2.
NOTE A through-floor lift can be used in small buildings, as an alternative to a passenger lift.
20
SANS 10400-S:2011
Edition 3
a) have a minimum internal dimension of 1,1 m in width and 1,4 m in depth, clear of surface finishes;
b) have a doorway with an unobstructed width of not less than 800 mm;
c) be fitted with horizontal handrails the full length of the lift car sides at a height of between 850 mm
and 1 000 mm above the floor level of the lift;
d) have a mirror on the top half of the rear wall equal to the width of the lift to enable wheelchair users to
back out of the lift where the lift has internal dimensions less than 1,5 m in width and 2,0 m in depth;
e) have a clear circulation space of not less than 1,5 m × 1,5 m at the entrance of the lift on each floor;
f) have audible and visible warnings in the lift lobby and lift car to indicate the lift car approaching, the
arrival of the lift, the lift doors opening, the lift doors closing, the floor requested and at which floor the
lift stops;
g) have control buttons, including emergency control buttons, that are in accordance with 4.14;
h) have illuminance on the control panel that is not less than 150 lx;
i) stop level with the landing on each floor that they serve.
NOTE 1 The provision of the number and size of lifts should take into account the number of persons (persons
with disabilities and persons without disabilities) using the site, complex or building. In buildings with large building-
user numbers and flow, the size and number of lifts should reflect the fact that a wheelchair user needs to be able
to turn when entering or exiting the lift.
NOTE 2 Wheelchair users should not have to travel further than non-wheelchair users to find a means of vertical
circulation accessible to them, and they should not have to cross roads or endanger their safety to reach such
means.
NOTE 3 To aid persons with visual impairments to operate automatic lifts, tactile identification, both raised
numbers on buttons, in contrasting light and dark colours, and Braille lettering adjacent to the number, should be
provided at the control panel within the lift car and external to it.
4.12.1 In any building where facilities for persons with disabilities are required in terms of Regulation S1
(see annex A), there shall be one or more toilets or unisex toilet facilities suitable for use by wheelchair
users, provided that
a) In any building requiring toilet facilities to which part S of the Regulations applies, the first toilet
provided shall be a unisex toilet facility, for use by persons with and without disabilities, preferably in
accordance with the details shown in annex D.
1) bedrooms are provided with private toilet facilities, at least one such bedroom in every 25 (or part
thereof) shall be provided with a toilet, washbasin and bath or shower accessible to persons with
disabilities; and
2) bedrooms are not provided with private toilet facilities, on each floor, at least one bathroom for
every 25 bedrooms shall be provided with a toilet and a washbasin accessible to persons with
disabilities, and at least one bathroom shall be provided with a bath or shower accessible to
persons with disabilities, regardless of the number of bedrooms in the hotel, lodging house, hostel
or hospitality accommodation.
21
SANS 10400-S:2011
Edition 3
c) In any building other than buildings of occupancy class H1, where in terms of SANS 10400-P, a toilet
is required, not fewer than one toilet accessible to persons with disabilities shall be provided within
every group of toilets provided.
d) Persons with disabilities shall not be required to travel further than persons without disabilities to get
to a toilet that is accessible to them (see annex B).
e) Persons with disabilities shall not be required to travel a distance of more than 45 m on the same
floor, or 25 m where horizontal and vertical distances are combined, in order to reach a toilet
accessible to them, regardless of the number of toilets available to persons without disabilities.
a) the door of the compartment that contains the toilet facilities shall open outwards unless a 1,2 m
diameter area that is clear of all fittings, fixtures and the line of the door swing is provided. It shall be
fitted with a grab rail on the inside and an easy-to-use locking device. The door leaf shall be
openable from the outside by the use of a suitable device in the case of an emergency, and such
leaf shall be fitted with a suitable means of indicating whether the compartment is occupied;
b) the minimum finished wall-to-wall dimensions of the compartment shall be not less than
1,8 m × 1,8 m;
c) a distance of not less than 450 mm and not more than 500 mm shall be provided between the centre
line of the toilet and the nearer side wall of such compartment, and suitable grab rails shall be fixed
to such side wall and the rear wall;
d) the distance from the front edge of the toilet to the rear wall of such compartment shall be not less
than 690 mm;
e) the top surface of the seat of the toilet shall be not less than 480 mm and not more than 500 mm
above the floor level;
f) unless the toilet is provided with a special back rest, the lid and seat thereof, when raised to the
upright position, shall remain in such position;
g) sanitary fixtures and fittings, such as the soap dispenser, hand drier, mirror, coat hooks and toilet
paper holder shall be easy to use and easily accessible to any person in a wheelchair. Hand-
operated metering faucets shall remain open for a minimum of 10 s;
h) the toilet flushing control shall be positioned on the outer side, on top of or behind the toilet, operable
from the transfer space and shall be easy to use;
1) be mounted without legs or pedestal, and the height from the floor to the top edge of such basin
shall be not more than 820 mm, and
2) have a vertical clearance of 650 mm from under the basin to the floor, measured at a point not
less than 160 mm from the front of and under the basin.
j) either a vanity slab or shelf shall be fitted in such compartment, level with the top of the washbasin,
with a clear height beneath it of 750 mm;
k) water supply to such a washbasin shall be by way of a single lever mixer unit with a lever handle at
least 100 mm long within reach of any person sitting on the toilet;
22
SANS 10400-S:2011
Edition 3
l) grab rail assemblies shall be manufactured and installed so as to meet the purpose for which they
are intended. The installation shall be sufficiently sturdy to withstand the loads imposed on them;
m) grab rails suitable for use by persons with disabilities shall be provided at the side and back of the
toilet. The tube of any grab rail shall have an outside diameter between 32 mm and 38 mm. The
back and side grab rail may be an integral unit;
n) In addition to the grab rails indicated in (m), a hinged support arm may be added to the transfer side
of the toilet, at 300 mm from the centre of the toilet
o) doors into accessible toilets shall have a clear opening of 900 mm minimum.
NOTE It is recommended that the maximum temperature of water discharging from any hot water outlet in any
building, should not exceed 45 °C. This is of particular importance in ablutions accessible by persons with
disabilities.
4.12.3 Any bath or shower cubicle provided for the use of persons with disabilities shall be so designed
that a wheelchair user should be able to roll into such cubicle without being obstructed by a kerb or
change of level.
4.12.4 Floor surfaces to any bath or shower cubicle provided for the use of persons with disabilities shall
have a firm and slip-resistant surface under wet and dry conditions.
NOTE Annex D provides further guidance on the design and layout of toilet facilities.
4.13.1 Where any building contains one or more auditoriums or halls fitted with fixed seating, floor
space accessible to any person in a wheelchair shall be set aside for the accommodation of wheelchairs
in such auditoriums or halls. Such space shall
a) be situated adjacent, or in close proximity, to an exit door and shall be so arranged that a wheelchair
will not obstruct any aisle or exit door, and
1) a minimum of one wheelchair where the number of fixed seats for which the auditorium or hall is
designed is not more than 50,
2) a minimum of two wheelchairs where the number of fixed seats for which the auditorium or hall is
designed is more than 50 but not more than 400, and
3) a minimum of three wheelchairs or a number of wheelchairs equal to 0,5 % of the number of fixed
seats for which the auditorium or hall is designed, whichever is the greater, where such number of
fixed seats is more than 400.
4.13.2 Wheelchair positions shall be distributed evenly throughout the facility. For each wheelchair
position a companion seat shall be provided.
4.13.3 Each space accessible to a wheelchair shall be not less than 900 mm × 1,4 m. Such a space
shall provide a line of vision of the performance comparable to the full range of seating that is not
wheelchair accessible.
4.14.1 All security controls and light switches shall be horizontally aligned with door handles and other
23
SANS 10400-S:2011
Edition 3
fixtures and fittings (other than socket outlets) between 900 mm and 1,2 m above the finished floor level,
as shown in figure 13.
NOTE 2 For persons with visual or dexterity impairments, rocker action, or push-pad switches that operate in the
vertical plane are preferable as long as they are easy to use. Push buttons of light switches should project clear of
the switch plate and have a width of at least 15 mm.
4.14.2 General-purpose socket outlets (power points) shall be fixed at least 500 mm above the finished
floor level, 150 mm above the worktop and at least 450 mm from the corners (see figure 13).
4.14.3 Emergency controls and other controls shall show their effective operation so that they include
persons with hearing loss. For example, an emergency alarm in a lift shall light up when pressed.
Dimensions in millimetres
Figure 13 — Heights for switches, general-purpose socket outlets and door handles
NOTE 1 Emergency warning signals include smoke detection, fire alarms and evacuation signals.
4.16 Lighting
4.16.1 The minimum illumination levels of lighting shall comply with the requirements of
SANS 10400-O and SANS 10389-1.
NOTE Many persons with disabilities, especially elderly persons and persons with visual impairments, require
higher levels of artificial lighting and reduced glare. Persons with hearing impairments might also require a higher
level of illumination to facilitate lip-reading.
4.16.2 Lighting controlled by passive infrared sensors shall be provided in external circulation areas,
internal circulation areas, and bathrooms, where these facilities are used after dark. Where passive
infrared sensors cannot be provided, night lights shall be provided.
NOTE Contrasting light and dark colours and levels of luminance should be used to assist persons with visual and
intellectual impairments.
24
SANS 10400-S:2011
Edition 3
Annex A
(informative)
S1 Application
(1) Facilities that accommodate persons with disabilities shall be provided in any building except the
following:
(a) any building of which the whole of the ground storey comprises one or more occupancies
classified in terms of regulation A20 as B1, B2, D4, H4, J1 or J2;
(b) any building classified as H1 in terms of regulation A20 where such building has less
than 25 bedrooms and it can be reasonably proven that it is not possible to include
wheelchair access in certain aspects of the design; and
(c) any storey above ground floor level of a building classified as H3 in terms of regulation A20
and not provided with a lift.
S2 Facilities to be Provided
(1) In any building contemplated in regulation S1 requiring facilities for persons with disabilities:
(a) persons with disabilities shall be able to safely enter the building, use all the facilities
subject to the provisions of subregulation (3) within it and leave it;
(b) there shall be a means of access suitable for use by persons with disabilities, from the main
and ancillary approaches of the building to the ground storey; via the main entrance, and any
secondary entrance;
(c) there shall be a means of egress suitable for use by persons with disabilities from any point
in a building to a place of safety in the event of an emergency;
(d) any lift installation that is provided shall be capable of serving the needs of persons with
disabilities who are likely to be using the building;
(e) any commonly used path of travel shall be free of obstacles which limit, restrict or
endanger the travel of persons with disabilities, or which prevent persons with disabilities
from accessing the facilities provided in the building and the presence of such obstruction
shall be made evident in a suitable manner to persons with impaired vision; and
(f) a suitable means of access shall be provided to any auditorium or hall situated in any
building and such auditorium or hall shall, in relation to its seating capacity, be provided with
sufficient open space to accommodate a reasonable number of persons who use
wheelchairs or other assistive devices.
(2) Where parking for more than 50 motor vehicles is provided in or in connection with any
building having a means of access contemplated in subregulation (1), adequate parking space
shall be provided for the parking of motor vehicles used by persons with disabilities and a
suitable means of access shall be provided from the parking area, whether such parking area
be inside or outside such building, to the ground storey of such building.
25
SANS 10400-S:2011
Edition 3
(3) Where, in terms of regulation P1, toilet facilities are required and the building is one requiring
facilities for persons with disabilities in terms of regulation S1, an adequate number of such
facilities shall be suitable for use by persons with disabilities: Provided that toilet facilities shall
not be required in any such building classified as H3 in terms of regulation A20.
S3 Deemed-to-Satisfy Requirements
The requirements of regulation S2 shall be deemed to be satisfied where –
(b) the egress from the building in the event of fire is in accordance with SANS 10400-T.
26
SANS 10400-S:2011
Edition 3
Annex B
(informative)
The provisions for facilities for persons with disabilities contained in the National Building Regulations
provide minimum requirements only and do not necessarily comply with the provisions of other
legislative requirements.
This annex provides the framework against which building owners, architects and other designers can
make decisions about the level of access they should provide. It also provides local authorities with
background information to enable them to make decisions in relation to the reasonableness of the
access that has been provided, when deciding whether to grant or refuse building approval.
Every effort should be made to provide accessible facilities in as many buildings as possible,
notwithstanding the fact that it might not always be a requirement of the National Building Regulations.
The potential to adapt buildings after construction might be prohibitive in terms of cost, and therefore any
decision made to include an inaccessible area of a site or building or facility at the design stage, when
such works are feasible, should not be taken lightly. A factor to be considered is that all facilities, if
designed correctly, can also provide safe, comfortable and convenient use to persons without
disabilities.
Equality (Section 9)
(3) The state may not unfairly discriminate directly or indirectly against anyone on one or more
grounds, including race, gender, sex, pregnancy, marital status, ethnic or social origin, colour,
sexual orientation, age, disability, religion, conscience, belief, culture, language and birth.
(4) No person may unfairly discriminate directly or indirectly against anyone on one or more grounds
in terms of subsection (3). National legislation must be enacted to prevent or prohibit unfair
discrimination.
27
SANS 10400-S:2011
Edition 3
Everyone has inherent dignity and the right to have their dignity respected and protected.
Everyone has the right to an environment that is not harmful to their health or well-being.
(a) promoting equal opportunity and fair treatment in employment through the elimination of unfair
discrimination; and
(b) implementing affirmative action measures to redress the disadvantages in employment experienced
by designated groups, in order to ensure their equitable representation in all occupational categories
and levels in the workforce.
Persons with disabilities are included in the definition of “designated groups” in the Act.
(a) measures to identify and eliminate employment barriers, including unfair discrimination, which
adversely affect people from designated groups;
(b) measures designed to further diversity in the workplace based on equal dignity and respect of all
people;
(c) making reasonable accommodation for people from designated groups in order to ensure that
they enjoy equal opportunities and are equitably represented in the workforce of a designated
employer.
Section 11 places the burden of proof on the employer to establish that an allegation of unfair
discrimination is fair.
Section 54(1) enables the Minister of Labour to issue codes of good practice to provide employers with
information that can assist them in implementing the Act.
The Code of good practice: Key aspects on the employment of people with disabilities asserts that
reasonable accommodation to eliminate barriers in the workplace to persons with disabilities include
Ɣ re-organizing workstations
28
SANS 10400-S:2011
Edition 3
provide and maintain, as far as is reasonably practicable, a working environment that is safe and without
risk to the health of his employees.
conduct his undertaking in such a manner as to ensure, as far as is reasonably practicable, that persons
other than those in his employment who may be directly affected by his activities are not thereby
exposed to hazards to their health or safety.
no person may unfairly discriminate against any person on the ground of disability, including –
(a) denying or removing from any person who has a disability, any supporting or enabling facility
necessary for their functioning in society;
(b) contravening the code of practice or regulations of the South African Bureau of Standards that
govern environmental accessibility;
(c) failing to eliminate obstacles that unfairly limit or restrict persons with disabilities from enjoying equal
opportunities or failing to take steps to reasonably accommodate the needs of such persons.
any act or omission, including a policy, law, rule, practice, condition or situation which directly or
indirectly –
(a) race, gender, sex, pregnancy, marital status, ethnic or social origin, colour, sexual orientation, age,
disability, religion, conscience, belief, culture, language and birth; or
(b) any other ground where discrimination based on that other ground –
(iii) adversely affects the equal enjoyment of a person’s rights and freedoms in a serious manner
that is comparable to discrimination on a ground in paragraph (a).
29
SANS 10400-S:2011
Edition 3
(a) the respondent must prove, on the facts before the court, that the discrimination did not take place
as alleged; or
(b) the respondent must prove that the conduct is not based on one or more of the prohibited grounds.
30
SANS 10400-S:2011
Edition 3
Annex C
(informative)
C.1 Introduction
The individual anthropometric and ergonomic requirements of persons with disabilities vary enormously.
Designers of buildings and local authorities who are responsible for approving alternative proposals
should appreciate the environmental impact for, or access needs of, persons with commonly accepted
categories of disability. The information provided below is given as guidance and is not exhaustive.
C.2 Vision
C.2.1 General considerations
Few persons are totally blind; most persons, even if legally blind, can perceive light and darkness, and
often some colours. The largest group of visually-impaired persons consists of those who have vision
just short of normal vision, to just short of light/dark-only perception. The main issues are to enable the
person to make the most of the sight that he does have by keeping in mind the value of size, lighting
colour and contrast, whilst also assisting those persons who are totally blind, and also to provide a safe
environment where the risk of injury is minimized.
For persons with impaired vision there are four main areas of consideration (see C.2.2 to C.2.5).
C.2.2 Navigation
Persons with visual impairments are likely to make use of white canes as navigational aids to detect
hazards in the built environment. They might also use guide dogs to guide them past obstacles. The
cane will detect objects up to approximately 1,0 m high. Persons with low vision will benefit from the
correct use of size, lighting, colour and contrast, since the majority of these do not use white canes.
Obstacles above waist height or overhanging items which do not have contact with the ground, as well
as windows that open onto pathways, will not be detected by a cane, therefore care should be taken to
avoid such hazards.
Information boards and advertisements along pedestrian routes should not be mounted on poles or
stands in such a way that a blind person's cane passes underneath it. If something that extends at least
300 mm above the ground is not placed beneath such boards or advertisements, this can cause serious
injury to a blind person's face.
Uneven surfaces, steps with irregular risers or open risers on flights of stairs are likely to cause persons
with visual impairments to trip and injure themselves. Quality of workmanship is extremely important in
avoiding gaps between surface finishes, raised thresholds, and to ensure that all steps have uniform
risers.
Environments should be well managed to avoid hazards developing, such as those caused by the
disintegration of a surface, or vegetation growing over a pathway. Consistency should be maintained, as
once a visually impaired person becomes familiar with a certain environment, he will find it easier to
navigate if the environment does not change.
The features required by persons with visual impairments benefit the general safety of the total building
population.
31
SANS 10400-S:2011
Edition 3
C.2.3 Orientation
The built environment can either create confusion or facilitate orientation. External pathways can be
designed to lead directly to the front entrance of a building, and a logical layout with good lighting, colour
and contrast can be provided so that it is easy for someone with impaired sight to learn and remember.
The majority of visually-impaired persons have low vision, which is not obvious as they will not be using
a white cane or guide dog, but try to navigate and orientate themselves by using their level of vision.
An object should be so designed that if it is knocked over by a person, he will not injure himself.
Rounded objects rather than sharp-cornered objects should be used.
Glare introduces debilitating effects to a person with a visual impairment. To avoid glare, attention
should be paid to the location of windows, the location and level of artificial light, the location of mirrors,
and the specification of reflective surfaces, fixtures and fittings.
Lighting should be achieved in such a way that it does not cause confusing shadows, pools of darkness
or over-brightness. Even, defuse lighting should be achieved.
Patterns should be utilized with care, to avoid visual confusion. It is difficult for persons with visual
impairments to locate a desired object against a patterned background. Patterns can be used to
enhance environments, for example, to direct persons towards the reception area or towards fire
escapes.
Colour, tone and luminance contrast should be used to aid the identification of critical surfaces.
Externally, critical surfaces include guiding walls, steps, rails and textured guidance surfaces. Internally,
critical surfaces that require an effective LRV level are ceilings, walls, floors, stairways, doors and
significant fixtures and fittings.
Signage should be designed so that it is easy to see in terms of its positioning, its size and type of font,
lighting and colour and There should be a clear link between information signs, directional signs,
identification signs and safety signs.
However, both landmarks and signage should complement environmental layout, and not be used to
compensate for illogical and confusing spaces.
32
SANS 10400-S:2011
Edition 3
C.3.2 Navigation
Problems with perception can result in an increased likelihood of tripping and falling, and an increased
tendency to bump into objects. Navigational factors that impact on persons with visual impairments
therefore apply equally here (see C.2.2).
C.3.3 Orientation
Difficulties with perception or cognition can lead to problems with orientation. The factors affecting
persons with visual impairments apply equally here (see C.2.3).
C.3.4 Comprehension
The use of symbols to aid comprehension, either to reinforce written information, or as its own universal
language, is recognized internationally.
Information on controls in the built environment should be easy to understand and the use of identical
control devices for different functions should be avoided.
C.4 Hearing
C.4.1 General considerations
The main concern is to enable persons with hearing loss to make use of their residual hearing. Provision
should also be made for persons who are completely deaf.
Care should be taken to ensure that noise from equipment used within the space does not interfere with
the desired acoustic signal.
33
SANS 10400-S:2011
Edition 3
Persons who are completely deaf are still sensitive to vibrations. This can be used positively, for
example, with the use of acoustic flooring.
Deaf persons will find very noisy environments uncomfortable due to the reverberations that they sense.
The factors that create clarity in the environment for persons with visual impairments, also create a safer
environment for persons with hearing impairments, and assist with lip-reading and the observation of
sign language interpreters.
Persons with impaired hearing are likely to be more reliant on their sight to compensate for their hearing
loss. Therefore effective lines of sight should be maintained. For example, persons with a hearing
impairment should be positioned so that they can see a door during a meeting, or when sitting at their
workstation, so that they are aware of who is entering and exiting.
When employing a sign language interpreter, lighting and other conditions within the visual environment
should be carefully planned so that the interpreter can be easily understood.
The use of visual or vibrating alarms integrated with audio-alarm systems, such as fire alarms, shall
receive particular attention in the building design phase.
C.5 Balance
Impaired balance can be caused by sensory loss or by motor dysfunction, therefore, care should be
taken in the built environment to avoid injury to children and adults with impaired balance.
Surfaces should be slip-resistant, friction-free and even, since persons with impaired balance are prone
to tripping and falling.
All steps, stairs and ramps should be fitted with handrails on both sides to reduce the risk of falling.
Protection should be provided from standing water and changes in level where someone could fall and
injure themselves.
Objects should be designed so that they do not cause injury on impact. Visual clarity and enhancement
using other senses will reduce the risk of injury for persons with impaired balance, as well as for persons
with visual impairments.
C.6 Touch
Impairments of sensation can be dangerous when contact with hot or very cold surfaces is likely.
Protection from hot pipes in toilets should be provided. Persons who have had a spinal injury often lose
sensation in their lower limbs, and can be burnt on pipework from taps, or from the heat from the
underside of a metal sink.
Persons with certain cognitive impairments might not react to burning, thus causing themselves injury.
34
SANS 10400-S:2011
Edition 3
Protection from hot surfaces, but also a control on the maximum temperature of hot water should be
considered.
Persons with certain neurological conditions cannot feel when they have come into contact with a sharp
object; therefore object design is important.
C.7.2 Incontinence
A range of factors are related to incontinence, from the need to go to the toilet, to the expected travel
distance to get to a toilet, and the toilet design. Many AIDS-related or other terminal illness conditions
cause incontinence, and therefore proximity to a toilet becomes very important. Incontinence is acutely
embarrassing and is often neglected in relation to building design and layout.
Distances between facilities, negotiating public transport and steps and stairs can cause problems for
persons who are predisposed to fatigue, whether or not they have mobility aids. This is a particular
problem for persons who have AIDS. The planning of facilities on the site should take this into account,
and resting facilities should be provided en route.
Predisposition to fatigue could make repetitive tasks or standing difficult, and the operation of doors,
windows, taps, handles, levers, switches, push-buttons, keys, etc. could pose problems. This can be
made easier by selecting operational levers that are easy to use and that require minimal force to
operate. Hands-free or electrically operated fixtures are preferable.
C.8 Height
C.8.1 General
Persons who are short in stature experience problems within the built environment that might not be
catered for by accommodating wheelchair users. Specific problem areas (not including reach (see C.9.2)
and fatigue (see C.7.3)) commonly experienced by persons of short stature are covered in C.8.2 to
C.8.4.
35
SANS 10400-S:2011
Edition 3
C.9.2 Reach
Persons with limited forward or side reach have difficulty operating levers and equipment. Children and
adults without disabilities who are short in stature are also affected. For wheelchair users, the provision
of knee space under surfaces is crucial to effective reach. When carrying out operational tasks, side
reach is not an effective compromise to front reach with the provision of knee space.
Persons operate within two reach ranges: comfortable and extended. Care should be taken to place
equipment and fittings used frequently within universally comfortable reach. Where this is not possible,
alternative methods of operation or individual modification might be necessary.
C.10 Circulation
C.10.1 General considerations
Persons who have mobility impairments might use various assistive devices, either manual or electric
wheelchairs, or wheelchairs pushed by a helper. Persons with ambulant disabilities might use crutches,
walking stick(s) or walking frames.
A wheelchair cannot be designed effectively without considering the person in the wheelchair as well. In
addition, wheelchair users vary in their ability to manoeuvre a wheelchair. This is particularly true when
turning, operating doors and when moving up a ramp.
The Regulations do not necessarily take all these factors into account. Therefore, whilst general
assessment can address most of the problems that affect wheelchair users, individual workplace
assessment that takes into account the individual's anthropometric and ergonomic requirements is likely
to be necessary.
36
SANS 10400-S:2011
Edition 3
Persons that use crutches, walking sticks or walking frames are in danger of tripping or slipping on
uneven or cobbled surfaces. Handrails should be provided on both sides of a stairway, to assist persons
going up or down. Many persons with ambulant disabilities find stairs easier to negotiate than a ramp,
since the travel distance is shorter.
Doorways should be wide enough to enable wheelchair users to pass through. The clear opening width
of the doorway is the key measure, which means that the allowance for the door width and the door
frame shall be in excess of the clear opening width. Where more manoeuvring space is required, such
as within a wheelchair-accessible toilet, a wider clear opening is needed to allow the wheelchair user to
turn within the doorway.
37
SANS 10400-S:2011
Edition 3
Annex D
(informative)
D.1 General
All dimensions are critical, the allowable tolerance being ± 10 mm. The size of a compartment should be
at least 1,8 m × 1,8 mm. The toilet roll holder should be positioned as shown in figures D.1 to D.6. A
shelf should be fitted adjacent to the basin.
D.2 Toilet
A 150 mm lever extension to the flush handle should be fitted to both cistern-type and flush-valve-type
toilets, and such extension should be located away from the side wall, as shown in figures D.1 and D.2.
The height from finished floor level to the top of the toilet seat should be 480 mm. The seat lid should
remain upright when raised, to act as a backrest.
38
SANS 10400-S:2011
Edition 3
Dimensions in millimetres
39
SANS 10400-S:2011
Edition 3
Dimensions in millimetres
Elevation A-A
Plan view
Whb = wash hand basin
Figure D.2 — Plan and elevation of a typical facility with a close-coupled toilet system
40
SANS 10400-S:2011
Edition 3
Dimensions in millimetres
41
SANS 10400-S:2011
Edition 3
Dimensions in millimetres
Elevation A-A
Plan view
Figure D.4 — Plan and elevation of a typical wall-hung toilet system with Flushmaster
42
SANS 10400-S:2011
Edition 3
Dimensions in millimetres
Figure D.5 — Layout of a typical wall-hung toilet system with concealed cistern
43
SANS 10400-S:2011
Edition 3
Dimensions in millimetres
Elevation A-A
Plan view
Figure D.6 — Plan and elevation of a typical wall-hung toilet system with concealed cistern
44
SANS 10400-S:2011
Edition 3
Dimensions in millimetres
Elevation
Plan view
45
SANS 10400-S:2011
Edition 3
Bibliography
Standards
BS 8300, Design of buildings and their approaches to meet the needs of disabled people – Code of
practice.
Other publications
Department of Transport. The Southern African Development Community Road Traffic Signs Manual
(SADC RTSM). 3rd ed., vol. 1 and 4. South Africa: Department of Transport, 1999.
© SABS
46
SABS – Standards Division
The objective of the SABS Standards Division is to develop, promote and maintain South African
National Standards. This objective is incorporated in the Standards Act, 2008 (Act No. 8 of 2008).
South African National Standards are updated by amendment or revision. Users of South African
National Standards should ensure that they possess the latest amendments or editions.
The SABS continuously strives to improve the quality of its products and services and would
therefore be grateful if anyone finding an inaccuracy or ambiguity while using this standard would
inform the secretary of the technical committee responsible, the identity of which can be found in
the foreword.
Tel: +27 (0) 12 428 6666 Fax: +27 (0) 12 428 6928
The SABS offers an individual notification service, which ensures that subscribers automatically
receive notification regarding amendments and revisions to South African National Standards.
Tel: +27 (0) 12 428 6883 Fax: +27 (0) 12 428 6928 E-mail: sales@sabs.co.za
Buying Standards
Contact the Sales Office for South African and international standards, which are available in both
electronic and hardcopy format.
Tel: +27 (0) 12 428 6883 Fax: +27 (0) 12 428 6928 E-mail: sales@sabs.co.za
South African National Standards are also available online from the SABS website
http://www.sabs.co.za
Information on Standards
The Standards Information Centre provides a wide range of standards-related information on both
national and international standards, and is the official WTO/TBT enquiry point for South Africa. The
Centre also offers an individual updating service called INFOPLUS, which ensures that subscribers
automatically receive notification regarding amendments to, and revisions of, international
standards.
Tel: +27 (0) 12 428 6666 Fax: +27 (0) 12 428 6928 E-mail: info@sabs.co.za
Copyright
The copyright in a South African National Standard or any other publication published by the SABS
Standards Division vests in the SABS. Unless exemption has been granted, no extract may be
reproduced, stored in a retrieval system or transmitted in any form or by any means without prior
written permission from the SABS Standards Division. This does not preclude the free use, in the
course of implementing the standard, of necessary details such as symbols, and size, type or grade
designations. If these details are to be used for any purpose other than implementation, prior written
permission must be obtained.