Pressure-Reducing Valve, Pilot-Controlled Type VDM: Product Documentation
Pressure-Reducing Valve, Pilot-Controlled Type VDM: Product Documentation
Pressure-Reducing Valve, Pilot-Controlled Type VDM: Product Documentation
Product documentation
pilot-controlled
Operating pressure pmax: 400 bar
Flow rate Qmax: 120 lpm
D 5579
09-2018-1.1
© by HAWE Hydraulik SE.
The reproduction and distribution of this document as well as the use and communication of its contents to others without explicit
authorisation is prohibited.
Offenders will be held liable for the payment of damages.
All rights reserved in the event of patent or utility model applications.
Brand names, product names and trademarks are not specifically indicated. In particular with regard to registered and protected names
and trademarks, usage is subject to legal provisions.
HAWE Hydraulik respects these legal provisions in all cases.
Printing date / document generated on: 25.09.2018
3 Parameters......................................................................................................................................................... 7
4 Dimensions...................................................................................................................................................... 10
4.1 Pipe connection................................................................................................................................................. 10
4.2 Manifold mounting............................................................................................................................................. 11
6 Other information.............................................................................................................................................14
6.1 Functional description........................................................................................................................................ 14
Pressure reducing valves are a type of pressure control valve. They maintain a
largely constant outlet pressure even at a variable (higher) inlet pressure.
The pressure reducing valve type VDM is hydraulically pilot-controlled. These
valves feature an override compensation, i.e. acting like a pressure-limiting valve
if the secondary pressure exceeds the set pressure e.g. due to external forces.
There is a design-related leakage ow.
Pressure reducing valve type VDM
Features and benets:
■ With safety valve function
■ Various adjustment options
■ Various additional functions
Intended applications:
■ General hydraulics
■ Jigs
■ Test benches
VDM 3 G H R - 250
Table 2 Size
Coding Adjustment area for outlet pressure max. inlet pressure max. pressure difference between
(bar) (bar) inlet pressure and outlet pressure
(bar)
N 8 ... 100 400 300
H 10 ... 400 400 300
Note
Always monitor the pressure gauge when setting or changing the pressure yourself!
Table 5 Adjustment
Coding Description
No designation Series, xed (tool adjustable)
R Manually adjustable
General information
Material Steel; nitrided valve housing, hardened and ground functional inner parts
Flow direction Work ow direction always P d A, in opposite direction free back pressure possible (see Sp-
Q characteristics), P = supply ow (primary side), A = consumer (secondary side)
Leakage oil (control oil drain) • with all valves independently of the pressure setting approx. 0.40 lpm
• escaping at L, unpressurised to the tank
Hydraulic uid Hydraulic oil: as per Part 1 to 3; ISO VG 10 to 68 according to DIN 51 519
Viscosity range: min. approx. 4 mm2/s
Optimal operating range: max. approx. 1500 mm2/s
Also suitable for biologically degradable pressure uids type HEPG (polyalkylene glycol) and
HEES (synthetic ester) at operating temperatures up to approx. +70°C.
Temperatures Ambient: approx. -40 ... +80°C, Fluid: -25 ... +80°C, Note the viscosity range!
Permissible temperature during start: -40°C (observe start-viscosity!), as long as the service
temperature is at least 20K higher for the following operation.
Biologically degradable pressure uids: Observe manufacturer's specifications. By considera-
tion of the compatibility with seal material not over +70°C.
A ow in the opposite direction A d P is only possible with the pilot valve closed, i.e. below
the outlet pressure set (control piston in open home position). The return ow should not
be greater than approx. 50% of Qmax here. If reversal of the ow direction is to be expected
during the control process (control piston in throttle position), the control piston would then
block the return ow. In such cases or when the full return ow must be possible in control
terms, a bypass check valve is required.
1 Size 4
2 Size 5
3 Size 3
Δp-QA characteristics
1 Pressure setting
2 Pressure drop approx. 5%
Type
VDM 3 G, VDX 3 G = 1.1 kg
VDM 4 G, VDX 4 G = 1.5 kg
VDM 5 G, VDX 5 G = 2.0 kg
VDM 4 P, VDX 4 P = 2.0 kg
VDM 5 P, VDX 5 P = 2.5 kg
Type a b c d e f g h i k l
VDM 3 G 60 65 30 25 34 27 11 51.5 7.5 8.5 56.5
VDM 4 G 65 71 40 26.5 39 25 15 55 10 7 60
Pilot valves
VDM VDX
Fixed Coding R
VDM 4 P VDM 5 P
VDX 4 P VDX 5 P
VDM 4 P VDM 5 P
VDX 4 P VDX 5 P
Danger
Risk to life caused by sudden movement of the hydraulic drives when dismantled incorrectly!
Risk of serious injury or death.
■ Depressurise the hydraulic system.
■ Perform safety measures in preparation for maintenance.
Note
■ Read the documentation carefully before usage.
■ The documentation must be accessible to the operating and maintenance staff at all times.
■ Keep documentation up to date after every addition or update.
Caution
Risk of injury on overloading components due to incorrect pressure settings!
Risk of minor injury.
■ Always monitor the pressure gauge when setting and changing the pressure.
Note
Fresh hydraulic uid from the drum does not always have the highest degree of purity. Under some circumstances the fresh
hydraulic uid must be ltered before use.
Adhere to the cleanliness level of the hydraulic uid in order to maintain faultless operation.
(also see cleanliness level in Chapter 3, "Parameters").
Conduct a visual inspection at regular intervals, but at least once per year, to check if the hydraulic connections are damaged. If
external leakages are found, shut down and repair the system.
Clean the device surface of dust deposits and dirt at regular intervals, but at least once per year.
Function
The pressure reducing valve type VDM and VDX is hydraulically pilot-controlled. It consists of a main valve and a pilot valve.
The required outlet pressure is set with the pilot valve (ange-mounted pressure-limiting valve).
In the main valve a spring-loaded piston (pressure maintenance valve) is controlled via the pilot valve. The piston continuously changes
a ow cross section as a function of the inlet pressure. If the inlet pressure increases, the throttle resistance increases by the same
amount. If the inlet pressure drops, the throttle resistance falls by the same amount. This maintains the outlet pressure (= difference
between inlet pressure and throttle resistance) at a constant level.
The control oil ow, which is necessary for the control action of the piston, is drained externally via the pilot valve as leakage ow.
Schematic diagram
1 Input
2 Output
3 Leakage oil
4 Main valve
5 Pilot valve
6 Sealing disc
Additional versions
■ Pressure-limiting valve type DV, DVE and DF: D 4350
■ Pressure-reducing valve type ADM: D 7120
■ Pressure-reducing valve type CDK: D 7745
■ Proportional pressure-reducing valve type PDM and PDMP: D 7584/1
■ Proportional pressure-limiting valve type PDV and PDM: D 7486
D 5579 - 09-2018-1.1
HAWE Hydraulik SE
Einsteinring 17 | 85609 Aschheim/Munich | Postfach 11 55 | 85605 Aschheim | Germany
Tel +49 89 379100-1000 | Fax +49 89 379100-91000 | info@hawe.de | www.hawe.com