Pump
Pump
Pump
Hydro 1000
Product data
Performance range 3
Hydro 1000 4
Type key 4
Operating conditions 4
Other versions on request 4
Function 5
Grundfos Control 1000 for 1 pump 5
Grundfos Control 1000 for 2-4 pumps 5
Flange dimensions 6
System components 6
Pump 7
Shaft seal 7
Motor 7
Materials CR 3, 5, 10, 15 and 20 7
Materials CR 32, 45, 64 and 90 8
Materials CRI, CRN 8
Dimensions and weights 8
Construction 8
Mechanical installation 9
Electrical installation 9
Performance curves
CR 3 10
CR 5 11
CR 10 12
CR 15 13
CR 20 14
CR 32 15
CR 45 16
CR 64 17
CR 90 18
Diaphragm tank
Diaphragm tank selection 27
2
Product data Hydro 1000
Performance range
H
[m] Hydro 1000
50 Hz
100
90
80
70
60
50
CR 5 CR 15 CR 32 CR 64
CR 3 CR 10 CR 20 CR 45 CR 90
40
30
3
Product data Hydro 1000
To ensure stable operation the booster set must be Operating pressure: max. 16 bar
fitted with a suitable diaphragm tank. The size of the Liquid temperature: 0°C to +70°C
diaphragm tank can be calculated according to the
Ambient temperature: +5°C to +40°C.
section "Diaphragm tank selection" at page 27.
Maximum suction lift (H):
The maximum suction lift (H) can be calculated as
And/or follows:
H= 10.33 m -
NPSH of the pump -
other suction losses -
a safety margin of 0.5 metres.
CS 1000
Maximum inlet pressure: 6.0 bar
Hydro 1000
Power range: up to 30 kW
DOL starting: up to 7.5 kW
SD starting: 11 to 30 kW
Power supply: 3 x 400 V, 50 Hz, PE.
Non-Return Isolating
TM04 3144 3808
4
Product data Hydro 1000
Pr2
Pr3
One pump in Two pumps Three pumps
operation in operation in operation
of all pumps.
After-run delay: Keeps pumps in operation after cut-
out pressure is reached.
Time control is particularly convenient to reduce the
Fig. 3 Control 1000 display for 1 pump
number of starts and stops per hour, to prevent water
hammer and negative pressure in the suction manifold
Protection:
A pressure switch or a level switch at the suction side as well as other problems that can arise under certain
can be used as dry-running protection. When the water conditions.
level or pressure has been restored, automatic or
manual resetting is possible.
5
Product data Hydro 1000
Flange dimensions
PN 16 flanges
System components
Versions
Pos. Description Quantity
"G" "P" "B" "L" "W" "N"
1 Control cabinet 1 Metal, painted Metal, painted Metal, painted Metal, painted Metal, painted Metal, painted
1.4301 1.4301
2 Panel stand 2 Galvanized steel Galvanized steel Galvanized steel Galvanized steel
(AISI 304) (AISI 304)
1.4301 1.4301 1.4301 1.4571 1.4571
3 Suction manifold 1 Galvanized steel
(AISI 304) (AISI 304) (AISI 304) (AISI 316 Ti) (AISI 316 Ti)
Brass NiCr- Brass NiCr- Brass NiCr- Brass NiCr- 1.4401 (AISI
2 per "Belgaqua"
4 Isolating valve plated or cast plated or cast plated or cast plated or cast 316) and cast
pump approved
iron iron iron iron iron
1.4301 1.4301
5 Base frame 1 Galvanized steel Galvanized steel Galvanized steel Galvanized steel
(AISI 304) (AISI 304)
1 per POM or 1.4401 1.4401
6 Non-return valve POM or cast iron POM or cast iron POM or cast iron POM or cast iron
pump (AISI 316) (AISI 316)
1.4301 1.4301 1.4301 1.4517 1.4517
7 Discharge manifold 1 Galvanized steel
(AISI 304) (AISI 304) (AISI 304) (AISI 316 Ti) (AISI 316 Ti)
8 Pump 1-4 CR CR* CR CRI CR(I) CRN
9 Diaphragm tank 1 Not in the standard scope of supply
* Version ACS on request.
Available also version "Z" with all components listed above in 1.4401 (AISI 316), including ball and nuts and fittings.
6
Product data Hydro 1000
between the pump head and the base by means of 50 Hz 3 x 220-240/380-415 V, for P2 ≤3 kW.
Standard voltages 3 x 380-415Δ V, for P 2 ≥ 4 kW.
staybolts. The base has suction and discharge ports on
the same level (in-line). Motor protection
All pumps are equipped with a maintenance-free All motors are protected by the control panel of the
mechanical shaft seal. booster set.
Three-phase Grundfos motors from 3 kW upwards have
a built-in thermistor (PTC) according to DIN 44082.
Single-phase motors have a built-in thermal overload
Motor
switch.
Pump head
High efficency Minimised energy cost
Low NPSH Improves suction capability
Air handling Reduces risks of dry-running
Allows to service the pump directly on site
New cartridge concept
without dismantling it from the booster set
mechanical seal
nor disassembling the liquid end
Outer sleeve Staybolt Allows to service the mechanical seal
Spacer coupling without disassembling the motor from the
pump (for 11 kW motor onwards)
Provices high resistance to pressure
Sleeve sealing pulses and withstands temperature
fluctuations as well as external forces
Wear resistance, improved dry-running
Silicon carbide
capability and handling of thermal shocks
bearings
enable longer operating time
Strong axial locking force and high torque
Reinforced shaft lock
lock system enable robust and reliable
Base ring
operation of rotating assembly
GR7376
shaft seal (cartridge type). Impeller Stainless steel 1.4301 AISI 304
Chamber Stainless steel 1.4301 AISI 304
Outer sleeve Stainless steel 1.4301 AISI 304
Shaft seal Description Max. temp. range [°C]
Cast iron
O-ring (cartridge) (balanced Base EN-JL1030 ASTM 25B
HQQE –30°C to +120°C EN-GJL-200
seal), SiC/SiC, EPDM
Neck ring PTFE
7
Product data Hydro 1000
Motor stool
Cast iron
EN-JL1030 ASTM 25B
based on construction:
EN-GJL-200
Shaft Stainless steel 1.4057 AISI 431 • Systems with the control cabinet mounted on the
Impeller Stainless steel 1.4301 AISI 304 pump base frame.
Chamber Stainless steel 1.4301 AISI 304 • Systems with the control cabinet mounted on a
Outer sleeve Stainless steel 1.4301 AISI 304 separate base frame.
O-ring for outer sleeve EPDM or FKM
• Systems with the control cabinet without a base
Cast iron ASTM
Base
EN-GJS-500-7
EN-JL1050
80-55-06
frame. therefore suitable for floor mounting.
Carbon- For further information, see the paragraph Dimensions
Neck ring graphite filled
PTFE A discharge manifold is mounted on the discharge side
Bearing ring Bronze of the pumps. An isolating valve and non-return valve
Bottom bearing ring TC/TC are mounted between the discharge manifold and the
Rubber parts EPDM or FKM individual pumps. The non-return valve may be
TC = Tungsten carbide (cemented).
mounted on the suction side on request.
Materials CRI, CRN A suction manifold is mounted on the suction side of the
The base, the pump head cover as well as vital pump pumps. An isolating valve is mounted between the
components of CRI and CRN pumps are made as suction manifold and the individual pumps.
follows:
8
Product data Hydro 1000
The pipework connected to the booster system must be Which is the right damper varies from installation to
of adequate size. installation, and a wrong damper may increase the
The pipes are connected to the manifolds of the booster vibration level. Vibration dampers should therefore be
system. sized by the supplier.
To optimize operation and mimimise noise and vibra- If the booster system is installed on a base frame with
tion, it may be necessary to consider vibration damp- vibration dampers, expansion joints should always be
ening of the booster system. fitted on the manifolds. This is important to prevent the
booster system from "hanging" in the pipework.
Noise and vibration are generated by the rotations in
the motor and pump and by the flow in pipework and
Electrical installation
fittings. The effect on the environment is subjective and
depends on correct installation and the state of the The electrical installation should be carried out by an
remaining system. authorized person in accordance with local regulations.
If booster systems are installed in blocks of flats or the • The electrical installation of the booster set must be
carried out in accordance with enclosure class
first consumer on the line is close to the booster
IP 54.
system, it is advisable to fit expansion joints on the
suction and discharge pipes to prevent vibration being • Make sure that the booster set is suitable for the
electricity supply to which it is connected.
transmitted through the pipework.
• Make sure that the wire cross-section corresponds
to the specifications in the wiring diagram.
Note: The mains connection should be carried out as
shown in the wiring diagram.
1 1
TM03 2154 3805
2 2
3 3
Fig. 7 Schematic view of hydraulic installation
Pos. Description
1 Expansion joint
2 Pipe support
3 Machine shoe
9
Performance curves Hydro 1000
with 1, 2, 3 or 4 pumps CR 3
CR 3
p H
[kPa] [m]
100 Hydro 1000
900 CR 3-15
90
50 Hz
800 80 ISO 9906 Annex A
700 70
600 60
500 50
400 40
1 2 3 4
300 30
p H
[kPa] [m]
70 CR 3-12
600 60
500 50
400 40
300 30 1 2 3 4
200 20
p H
[kPa] [m]
60 CR 3-10
500 50
400 40
300 30
1 2 3 4
200 20
p H
[kPa] [m]
50 CR 3-8
400 40
300 30
200 20 1 2 3 4
100 10
p H
[kPa] [m]
40 CR 3-7
300 30
200 20
1 2 3 4
100 10
p H
[kPa] [m]
40 CR 3-6
300 30
200 20
1 2 3 4
100 10
p H
[kPa] [m]
300 30 CR 3-5
200 20
100 10 1 2 3 4
0 0
TM02 2119 4003
0 2 4 6 8 10 12 14 16 18 Q [m³/h]
0 1 2 3 4 5 Q [l/s]
10
Performance curves Hydro 1000
with 1, 2, 3 or 4 pumps CR 5
CR 5
p H
[kPa] [m]
100
Hydro 1000
CR 5-15
900 90 50 Hz
800 80 ISO 9906 Annex A
700 70
600 60
500 50
1 2 3 4
400 40
p H
[kPa] [m]
80 CR 5-13
700 70
600 60
500 50
400 40 1 2 3 4
300 30
p H
[kPa] [m]
60 CR 5-10
500 50
400 40
300 30 1 2 3 4
200 20
p H
[kPa] [m]
60 CR 5-9
500 50
400 40
300 30
1 2 3 4
200 20
p H
[kPa] [m]
50 CR 5-8
400 40
300 30
1 2 3 4
200 20
p H
[kPa] [m]
40 CR 5-7
300 30
200 20 1 2 3 4
100 10
p H
[kPa] [m]
300 30 CR 5-5
200 20
100 10 1 2 3 4
0 0
TM02 2132 4003
0 4 8 12 16 20 24 28 32 Q [m³/h]
0 2 4 6 8 Q [l/s]
11
Performance curves Hydro 1000
with 1, 2, 3 or 4 pumps CR 10
CR 10
p H
[kPa] [m]
100 Hydro 1000
900 CR 10-10
90
50 Hz
800 80 ISO 9906 Annex A
700 70
600 60 1 2 3 4
500 50
p H
[kPa] [m]
90 CR 10-9
800 80
700 70
600 60
1 2 3 4
500 50
p H
[kPa] [m]
80 CR 10-8
700 70
600 60
500 50
1 2 3 4
400 40
p H
[kPa] [m]
70 CR 10-7
600 60
500 50
400 1 2 3 4
40
p H
[kPa] [m]
60 CR 10-6
500 50
400 40
1 2 3 4
300 30
p H
[kPa] [m]
50 CR 10-5
400 40
300 30 1 2 3 4
200 20
p H
[kPa] [m]
40 CR 10-4
300 30
200 20 1 2 3 4
100 10
p H
[kPa] [m]
30 CR 10-3
200 20
1 2 3 4
100 10
0 0
TM02 7779 4003
0 5 10 15 20 25 30 35 40 45 50 Q [m³/h]
0 2 4 6 8 10 12 14 Q [l/s]
12
Performance curves Hydro 1000
with 1, 2, 3 or 4 pumps CR 15
CR 15
p H
[kPa] [m]
110
Hydro 1000
CR 15-8
1000 100 50 Hz
900 90 ISO 9906 Annex A
800 80
700 70
600 1 2 3 4
60
500 50
p H
[kPa] [m]
100 CR 15-7
900 90
800 80
700 70
600 60
1 2 3 4
500 50
p H
[kPa] [m]
80 CR 15-6
700 70
600 60
500 50
1 2 3 4
400 40
p H
[kPa] [m]
70 CR 15-5
600 60
500 50
400 40 1 2 3 4
300 30
p H
[kPa] [m]
50 CR 15-4
400 40
300 30 1 2 3 4
200 20
p H
[kPa] [m]
40 CR 15-3
300 30
200 20 1 2 3 4
100 10
p H
[kPa] [m]
300 30 CR 15-2
200 20
1 2 3 4
100 10
0 0
0 10 20 30 40 50 60 70 80 90 Q [m³/h]
TM02 7780 4003
0 5 10 15 20 25 Q [l/s]
13
Performance curves Hydro 1000
with 1, 2, 3 or 4 pumps CR 20
CR 20
p H
[kPa] [m]
100
Hydro 1000
CR 20-7
900 90 50 Hz
800 80 ISO 9906 Annex A
700 70
600 60
500 50 1 2 3 4
400 40
p H
[kPa] [m]
900 90 CR 20-6
800 80
700 70
600 60
500 50
1 2 3 4
400 40
p H
[kPa] [m]
700 70 CR 20-5
600 60
500 50
400 40
1 2 3 4
300 30
p H
[kPa] [m]
600 60 CR 20-4
500 50
400 40
300 30 1 2 3 4
200 20
p H
[kPa] [m]
400 40
CR 20-3
300 30
200 20 1 2 3 4
100 10
p H
[kPa] [m]
300 30
CR 20-2
200 20
1 2 3 4
100 10
0 0
TM02 7781 4003
0 5 10 15 20 25 30 Q [l/s]
14
Performance curves Hydro 1000
with 1, 2, 3 or 4 pumps CR 32
CR 32
p H
[kPa] [m]
120 Hydro 1000
1100 CR 32-6
110
50 Hz
1000 100 ISO 9906 Annex A
900 90
800 80
700 70
600 60
1 2 3 4
500 50
p H
[kPa] [m]
100 CR 32-5
900 90
800 80
700 70
600 60
1 2 3 4
500 50
p H
[kPa] [m]
80 CR 32-4
700 70
600 60
500 50
400 40 1 2 3 4
300 30
p H
[kPa] [m]
60 CR 32-3
500 50
400 40
300 30 1 2 3 4
200 20
p H
[kPa] [m]
400 40
CR 32-2
300 30
200 20
1 2 3 4
100 10
p H
[kPa] [m]
300 30
CR 32-2-2
200 20
100 10 1 2 3 4
TM01 3610 4003
0 0
0 20 40 60 80 100 120 140 160 Q [m³/h]
15
Performance curves Hydro 1000
with 1, 2, 3 or 4 pumps CR 45
CR 45
p H
[kPa] [m]
1000
Hydro 1000
100 CR 45-4
50 Hz
900
90 ISO 9906 Annex A
800 80
700 70
600 60
1 2 3 4
500 50
p H
[kPa] [m]
800 CR 45-3
80
700 70
600 60
500 50
400 40 1 2 3 4
300 30
p H
[kPa] [m]
CR 45-2
500 50
400 40
300 30
1 2 3 4
200 20
p H
[kPa] [m]
CR 45-2-2
400 40
300 30
200 20
1 2 3 4
100 10
p H
[kPa] [m]
CR 45-1
300 30
200 20
100 10 1 2 3 4
0 0
TM01 3611 4003
0 10 20 30 40 50 60 Q [l/s]
16
Performance curves Hydro 1000
with 1, 2, 3 or 4 pumps CR 64
CR 64
p H
[kPa] [m]
1200 Hydro 1000
120
CR 64-4
1100 50 Hz
110
ISO 9906 Annex A
1000 100
900 90
800 80
700 70 1 2 3 4
600 60
p H
[kPa] [m]
1000 CR 64-4-2
100
900 90
800 80
700 70
600 60
1 2 3 4
500 50
p H
[kPa] [m]
800 CR 64-3-1
80
700 70
600 60
500 50
1 2 3 4
400 40
p H
[kPa] [m]
CR 64-2
600 60
500 50
400 40
1 2 3 4
300 30
p H
[kPa] [m]
CR 64-2-2
400 40
300 30
200 20
1 2 3 4
100 10
TM01 3612 4003
0 20 40 60 80 100 Q [l/s]
17
Performance curves Hydro 1000
with 1, 2, 3 or 4 pumps CR 90
CR 90
p H
[kPa] [m]
110 Hydro 1000
1000 CR 90-4-2
100
50 Hz
900 90 ISO 9906 Annex A
800 80
700 70
600 60
500 50
1 2 3 4
400 40
p H
[kPa] [m]
100 CR 90-3
900 90
800 80
700 70
600 60
500 50
1 2 3 4
400 40
p H
[kPa] [m]
80 CR 90-3-2
700 70
600 60
500 50
400 40
300 30
1 2 3 4
200 20
p H
[kPa] [m]
60 CR 90-2
500 50
400 40
300 30
1 2 3 4
200 20
p H
[kPa] [m]
40 CR 90-2-2
300 30
200 20
100 10
1 2 3 4
0 0
p H
[kPa] [m]
300 30 CR 90-1
200 20
100 10
1 2 3 4
0 0
TM01 3613 4003
0 50 100 150 200 250 300 350 400 450 500Q [m³/h]
18
Dimensions and weights Hydro 1000
1 pump
HQ
H
Fig. 8 Dimensional sketch of a Hydro 1000 booster set with a control cabinet centred the base plate
HQ
H
B1
L B
Fig. 9 Dimensional sketch of a Hydro 1000 booster set with a control cabinet centred on the base plate
TM04 3143 3808
Fig. 10 Dimensional sketch of a Hydro 1000 booster set with a control cabinet centred on the base plate
19
Dimensions and weights Hydro 1000
1 pump
Design A: Hydro 1000 booster set with a control cabinet mounted on the same base plate as the pumps.
Design B: Hydro 1000 booster set with a control cabinet centred on the base plate.
Design C: Hydro 1000 booster set with a floor-mounted control cabinet.
Design D: Hydro 1000 booster set with a control cabinet mounted on a separate base plate.
Dimensions may vary by ± 20 mm.
20
Dimensions and weights Hydro 1000
2 pumps
HQ
H
B1
L
B
Fig. 11 Dimensional sketch of a Hydro 1000 booster set with a control cabinet centred the base plate
HQ
H
L B1
B
Fig. 12 Hydro 1000 booster set with a control cabinet mounted on the same base plate as the pumps.
HQ
H
L LQ B1
B
Fig. 13 Hydro 1000 booster set with a control cabinet mounted on a separate base plate.
21
Dimensions and weights Hydro 1000
2 pumps
Design A: Hydro 1000 booster set with a control cabinet mounted on the same base plate as the pumps.
Design B: Hydro 1000 booster set with a control cabinet centred on the base plate.
Design C: Hydro 1000 booster set with a floor-mounted control cabinet.
Design D: Hydro 1000 booster set with a control cabinet mounted on a separate base plate.
Dimensions may vary by ± 20 mm.
22
Dimensions and weights Hydro 1000
3 pumps
HQ
H
B1
L
B
Fig. 14 Hydro 1000 booster set with a control cabinet mounted on the same base plate as the pumps.
HQ
H
B1
L B
Fig. 15 Hydro 1000 booster set with a control cabinet mounted on the same base plate as the pumps.
HQ
H
B1
L LQ
B
Fig. 16 Hydro 1000 booster set with a control cabinet mounted on a separate base plate.
23
Dimensions and weights Hydro 1000
3 pumps
Design A: Hydro 1000 booster set with a control cabinet mounted on the same base plate as the pumps.
Design B: Hydro 1000 booster set with a control cabinet centred on the base plate.
Design C: Hydro 1000 booster set with a floor-mounted control cabinet.
Design D: Hydro 1000 booster set with a control cabinet mounted on a separate base plate.
Dimensions may vary by ± 20 mm.
24
Dimensions and weights Hydro 1000
4 pumps
HQ
H
B1
L B
Fig. 17 Hydro 1000 booster set with a control cabinet mounted on the same base plate as the pumps.
HQ
H
B1
L LQ B
Fig. 18 Hydro 1000 booster set with a control cabinet mounted on a separate base plate.
HQ
H
B1
L LQ B
25
Dimensions and weights Hydro 1000
4 pumps
Design A: Hydro 1000 booster set with a control cabinet mounted on the same base plate as the pumps.
Design B: Hydro 1000 booster set with a control cabinet centred on the base plate.
Design C: Hydro 1000 booster set with a floor-mounted control cabinet.
Design D: Hydro 1000 booster set with a control cabinet mounted on a separate base plate.
Dimensions may vary by ± 20 mm.
26
Diaphragm tank Hydro 1000
Diaphragm tank selection The diaphram tank may also be selected on the basis
of the below tables in which the following values have
To ensure stable operation, the Hydro 1000 booster set
been used:
must be installed in combination with an adequate
diaphragm tank. Motors up to and including 3.0 kW: n = 30 to 100
Motors above 3.0 kW: n = 10 to 30
The size of the obligatory diaphragm tank can be
Diff. between cut-in and cut-out: Δp = 1.5 [bar]
calculated by means of the followong formula:
Grundfos pumps and motors are not subject to any
particular limitations as they are tested up to 100 start/
Q × 1000 × ( 1 + ( cut – in ) + Δp ) 1
V = ------------------------------------------------------------------------------------ × -- stops per hour.
4× n × Δp k
max
However when dimensioning the diaphragm tank
V = Tank volume [litres] volume the following parameters may also be
Q = Mean flow [m3/h] considered:
Δp = Difference between cut-in and • maximum number of start/stops per hour allowed by
cut-out pressure local regulations
• maximum number of start/stops per hour described
Cut-in = Cut-in pressure (lowest) [bar] by the system designer
nmax = Max. number of starts/stops per hour • temperature and ventilation conditions
k = Constant for diaphragm tank pre-charge • available space for diaphragm tank installation.
pressure: k = 0.9
Minimum diaphragm tank volume [litres] at Δp = 1.5 [bar] and nmax = 30:
Minimum diaphragm tank volume [litres]
Pump type Cut-in Cut-in Cut-in Cut-in Cut-in Cut-in Cut-in Cut-in
1 [bar] 2 [bar] 3 [bar] 4 [bar] 5 [bar] 6 [bar] 7 [bar] 8 [bar]
CR 3 65 84 102 120 140 158 176 195
CR 5 108 135 170 200 232 263 294 324
CR 10 173 222 272 321 370 420 469 518
CR 15 346 444 543 642 741 839 938 1037
CR 20 432 556 679 802 926 1049 1173 1296
CR 32 691 889 1086 1284 1481 1679 1876 2074
CR 45 972 1250 1528 1805 2083 2361 2639 2916
CR 64 1383 1778 2173 2568 2963 3358 3753 4148
CR 90 1944 2500 3055 3611 4166 4722 5277 5833
Minimum diaphragm tank volume [litres] at Δp = 1.5 [bar] and nmax = 100:
Minimum diaphragm tank volume [litres]
Pump type Cut-in Cut-in Cut-in Cut-in Cut-in Cut-in Cut-in Cut-in
1 [bar] 2 [bar] 3 [bar] 4 [bar] 5 [bar] 6 [bar] 7 [bar] 8 [bar]
CR 3 20 25 30 36 42 47 53 59
CR 5 33 41 51 60 70 78 88 98
CR 10 52 67 81 96 111 126 141 156
CR 15 104 133 163 193 222 252 281 311
CR 20 130 167 204 241 278 315 352 389
CR 32 207 267 326 385 444 504 563 622
CR 45 292 375 458 542 625 708 792 875
CR 64 415 533 652 770 889 1007 1126 1244
CR 90 583 750 917 1083 1250 1417 1583 1750
Refer to the cut-in pressure closest to the lowest setting of the selected booster set.
27
Further product documentation Hydro 1000
WebCAPS
WebCAPS is a Web-based Computer Aided Product
Selection program available on www.grundfos.com.
WebCAPS contains detailed information on more than
185,000 Grundfos products in more than 20 languages.
In WebCAPS, all information is divided into 6 sections:
• Catalogue
• Literature
• Service
• Sizing
• Replacement
• CAD drawings.
Catalogue
Literature
In this section you can access all the lastest documents of a given
pump, such as
• data booklets
• Installation and operating instructions
• service documentation, such as Service kit catalogue and
Service kit instructions
• quick guides
• product brochures, etc.
Service
28
Further product documentation Hydro 1000
Sizing 0 1
Replacement
CAD drawings
2-dimensional drawings
• .dxf, wireframe drawings
• .dwg, wireframe drawings.
3-dimensional drawings
• .dwg, wireframe drawings (without surfaces)
• .stp, solid drawings (with surfaces)
• .eprt, E-drawings.
WinCAPS
WinCAPS is a Windows-based Computer Aided
Product Selection program containing detailed inform-
tion on more than 185,000 Grundfos products in more
than 20 languages.
The program contains the same features and functions
as WebCAPS, but is an ideal solution if no Internet
connection is available.
WinCAPS is available on CD-ROM and updated once a
year.
Fig. 20 WinCAPS CD-ROM
29
30
31
Being responsible is our foundation
Thinking ahead makes it possible
Innovation is the essence