Laurel: Laureate™ Digital Panel Meter For Process, Strain & Potentiometer Follower Signals
Laurel: Laureate™ Digital Panel Meter For Process, Strain & Potentiometer Follower Signals
Laurel: Laureate™ Digital Panel Meter For Process, Strain & Potentiometer Follower Signals
Features
• Selectable ±0.2, ±2, ±20, ±200, ±300 & ±600 Vdc voltage ranges
• Selectable ±2, ±20, ±200 mA and ±5A dc current ranges
• All ranges factory calibrated
• 99.99% full scale accuracy
• Scalable to ±99,999 for display in engineering units
• Up to 60 conversions per second
• Peak or valley capture & display
• Universal AC power: 85-264 Vac
• Built-in isolated excitation supply: 5, 10 or 24 Vdc
• Ratiometric compensation for variations in excitation voltage
• 1/8 DIN case sealed to NEMA-4X from front panel
• Optional serial I/O: Ethernet, USB, RS232, RS485, Ethernet-to-RS485 converter
• Optional relay output: dual or quad relays, contact or solid state
• Optional isolated analog output: 4-20 mA, 0-20 mA, 0-10V, -10 to +10V
• Optional low voltage power: 10-48 Vdc or 12-32 Vac
Description
Laureate™ digital process and strain panel meters are a cost- Peak and valley values are automatically captured. These may
effective solution to monitoring and control applications which be displayed via a front panel pushbutton command or control
require zero and span adjustment for process signals such as signal at the rear connector, or be transmitted as serial data.
4-20 mA, 0-5 V, 0-10 V, or strain gauges. The meters are also
suitable for potentiometer follower applications, where the High read rates at up to 60 or 50 conversions per second while
transducer output is a changing resistance. integrating the signal over a full power cycle are provided by
Concurrent Slope (US Pat 5,262,780) analog-to-digital conver-
The display is scalable to five digits from -99,999 to +99,999 sion. High read rates are ideal for peak or valley capture, real-
from the front panel to read directly in engineering units, such time computer interface, and control. Peak and valley values are
as PSI. Three scaling methods are selectable: scale and offset, automatically captured. These may be displayed via a front panel
two-point method, and system-level calibration using actual pushbutton command or a control signal at the rear connector, or
transducer signals. All ranges are precalibrated at the factory, so be transmitted as serial data.
that recalibration is not needed when changing ranges or signal
conditioners. Digital filtering is selectable for electrically noisy environments,
including a batch averaging filter and an adaptive moving aver-
Strain gauges with a 20 mV output can be scaled to display up age filter which provides a choice of 8 time constants from 80 ms
to 10,000 counts with a 4-wire ratiometric connection, while 200 to 9.6 s. When a significant change in signal level occurs, that
mV outputs of can be scaled to display up to 99,999 counts. For filter adapts by briefly switching to the shortest time constant to
higher sensitivity, 20 mV signals can be scaled to 99,999 counts follow the change, then reverts back to the selected time con-
with a 4- or 6-wire connection using the Laureate load cell meter. stant. In a selectable Auto filter mode, the filter time constant is
automatically selected based on detected signal noise.
A high input impedance of 1 Gohm is provided on 200.00 mV
and 2.000 V ranges to minimize the load on the voltage signal. Designed for system use. Optional plug-in boards include
Ethernet and other serial communication boards, dual or quad
An isolated 5, 10 or 24 Vdc isolated excitation output is relay boards, and an isolated analog output board. Laureates
standard to power external transducers and transmitters. Up to may be powered from 85-264 Vac or optionally from 12-32 Vac
120 mA is provided at 10V to power four 350 ohm load cells in or 10-48 Vdc. The display is available with red or green LEDs.
parallel. When powering strain gauges, load cells or potentio- The 1/8 DIN case meets NEMA 4X (IP65) specifications from the
meters, the excitation output is monitored by the meter to front when panel mounted. Any setup functions and front panel
eliminate errors due to voltage variations. keys can be locked out for simplified usage and security. A built-
High read rates at up to 60 or 50 conversions per second while in isolated 5, 10, or 24 Vdc excitation supply can power trans-
integrating the signal over a full power cycle are provided by ducers and eliminate the need for an external power supply. All
Concurrent Slope (US Pat 5,262,780) analog-to-digital conver- power and signal connections are via UL / VDE / CSA rated
sion. High read rates are ideal for peak or valley capture, real- screw clamp plugs.
time computer interface, and control.
LAUREL ELECTRONICS INC., 3183-G Airway Ave., Costa Mesa, CA 92626, USA • Tel 714-434-6131 • www.laurels.com 1
Specifications
±200.00 mV 10 µV 1 GΩ 0.01% FS
±2.0000 V 100 µV 1 GΩ 0.01% FS
±20.000 V 1 mV 10 MΩ 0.01% FS
±200.00 V 10 mV 10 MΩ 0.01% FS
±600.0 V * (not UL) 100 mV 10 MΩ 0.02% FS
300.0 V 100 mV 10 MΩ 0.02% FS
Display
A-to-D Conversion
Accuracy
Noise Rejection
CMR, DC to 60 Hz 130 dB
NMR at 50/60 Hz 90 dB with min filtering
Maximum Signal
Max applied voltage 600 Vac for 20, 200 and 300 V ranges, 125 Vac for other ranges
Current protection 25x for 2 mA, 8x for 20 mA, 2.5x for 200 mA, 1x for 5 A
Power
Voltage, standard 85-264 Vac or 90-300 Vdc (DC operation is not UL approved)
Voltage, optional 12-32 Vac or 10-48 Vdc
Frequency DC or 47-63 Hz
Power Isolation 250V rms working, 2.3 kV rms per 1 min test
Selectable levels 5 Vdc ± 5%, 100 mA; 10 Vdc ± 5%, 120 mA; 24 Vdc ± 5%, 50 mA
Output isolation 50 Vdc to meter ground
Output levels 4-20 mA, 0-20 mA, 0-10V, -10 to +10V (jumper selectable)
Current compliance 2 mA at 10V ( > 5 kΩ load)
Voltage compliance 12V at 20 mA (< 60Ω load)
Scaling Zero and full scale adjustable from -99999 to +99999
Resolution 16 bits (0.0015% of full scale)
Isolation 250V rms working, 2.3 kV rms per 1 min test
LAUREL ELECTRONICS INC., 3183-G Airway Ave., Costa Mesa, CA 92626, USA • Tel 714-434-6131 • www.laurels.com 2
Relay Outputs (optional)
Relay types 2 Form C contact relays or 4 Form A contact relays (normally open)
2 or 4 Form A, AC/DC solid state relays (normally open)
Current ratings 8A at 250 Vac or 24 Vdc for contact relays
120 mA at 140 Vac or 180 Vdc for solid state relays
Output common Isolated commons for dual relays or each pair of quad relays
Isolation 250V rms working, 2.3 kV rms per 1 min test
Signal Connections
Environmental
Mechanical
LAUREL ELECTRONICS INC., 3183-G Airway Ave., Costa Mesa, CA 92626, USA • Tel 714-434-6131 • www.laurels.com 3
Application Examples
Potentiometer Application
In potentiometric (or potentiometer follower) applications, the For use with a 1 kohm potentiometer, the recommended applied
signal from a sliding contact voltage divider can be converted to excitation voltage is 10 V, and a 2 kohm resistor should be
engineering units such as position, level or percentage. By ope- placed in series with the excitation output and excitation return
rating in a ratiometric mode, the meter will remove any effects leads. This will allow the meter's 2.0000 V scale with a high input
caused by variations in the excitation supply. impedance of 1 Gohm to be used.
The Laureate DC meter with the Extended main board option The Extended computer board allows the display of rate based
allows exceptionally accurate custom curve linearization. For on successive readings, for instance flow rate based on changes
setup, up to 180 data points can be entered into a spreadsheet. in liquid level or static pressure in a tank. In the above illustration,
The system then creates multiple non-linear spline-fit segments, the meter displays the rate in gallons at which a horizontal tank
which provide much better accuracy than linear segments. is being emptied. The input to the meter can be nonlinear, since
Illustrated, is the readout of volume of irregularly shaped tanks only the linearized readings are compared for the determination
based on measured liquid level or pressure. Altimeters and of rate.
thermistors are further applications.
LAUREL ELECTRONICS INC., 3183-G Airway Ave., Costa Mesa, CA 92626, USA • Tel 714-434-6131 • www.laurels.com 4
Ordering Guide
Create a model a model number in this format: L10000P, IPC
Note: Extended capability is required for custom curve linearization or for display of
time rate of change, such as flow rate from changing tank level or acceleration from
changing speed.
Note: The same DC signal conditioner board can be user-configured for process,
strain, potentiometer follower, DC Volts and DC Amps. It is precalibrated in EEPROM
for all Laureate DC Volt and DC Amp ranges.
LAUREL ELECTRONICS INC., 3183-G Airway Ave., Costa Mesa, CA 92626, USA • Tel 714-434-6131 • www.laurels.com 5