Section 2 Structure and Function
Section 2 Structure and Function
Section 2 Structure and Function
45070MP00
2-1
1) MAIN PUMP(1/2)
The main pump consists of two piston pumps(front & rear) and valve block.
45070MP03
2-2
04 Gear pump 262 Cover 548 Feed back pin
080 Proportional reducing 271 Pump casing 702 O-ring
valve assy 312 Valve cover 709 O-ring
111 Drive shaft 313 Valve plate(R) 711 O-ring
113 Driven shaft 314 Valve plate(L) 712 O-ring
123 Roller bearing 405 Hexagon socket bolt 724 O-ring
124 Needle bearing 406 Hexagon socket bolt 725 O-ring
126 Spacer 408 Hexagon socket bolt 726 O-ring
127 Spacer 409 Hexagon socket bolt 728 O-ring
128 Bearing spacer 410 Hexagon socket bolt 732 O-ring
129 Bearing spacer 411 Hexagon socket bolt 752 Seat packing
130 Booster 412 Hexagon socket bolt 774 Oil seal
131 Booster cover 413 Hexagon socket bolt 789 Back up ring
141 Cylinder block 467 Plug 792 Back up ring
151 Piston 469 Plug 806 Nut
152 Shoe 490 Plug 807 Nut
153 Plate 491 Plug 823 Snap ring
156 Bushing 492 Restrictor 824 Snap ring
157 Cylinder spring 493 Plug 825 Snap ring
171 Front casing 531 Tilting pin 827 Snap ring
191 Drive gear 532 Servo piston 828 Snap ring
192 Driven gear 534 Stopper(L) 885 Valve plate pin
211 Shoe plate 535 Stopper(S) 886 Spring pin
212 Swash plate 536 Servo cover 888 Pin
214 Tilting bushing 541 Seat 901 Eye bolt
251 Swash plate support 543 Stopper 953 Set screw
261 Front cover 545 Steel ball 954 Set screw
2-3
MAIN PUMP(2/2)
45070MP04
2-4
2) REGULATOR(1/2)
45070RG01
Pm Qmax cut port PF 1/4 - 15
2-5
REGULATOR(2/2)
45070RG02
2-6
3) GEAR PUMP
45070RG03
2-7
2. FUNCTION
1) MAIN PUMP
The pumps may classified roughly into the rotary group performing a rotary motion and working as
the major part of the whole pump function: the swash plate group that varies the delivery rates: and
the valve cover group that changes over oil suction and discharge.
2-7 (210-7)
2-8
(3) Valve cover group
The valve cover group consists of valve
cover(312), valve plate(313, 314),
booster(130), boost cover(131) and valve
plate pin(885).
The valve plate having two melon-shaped
ports is fixed to the valve cover and feeds
and collects oil to and from the cylinder
cover.
The oil changed over by the valve plate is
connected to an external pipeline by way
of the valve cover.
Now, if the drive shaft is driven by a prime
mover(electric motor, engine, etc), it
rotates the cylinder block via a spline
linkage at the same time. If the swash
plate is tilted as in Fig(previous page) the
pistons arranged in the cylinder block
make a reciprocating motion with respect
to the cylinder block, while they revolve
with the cylinder block.
If you pay attention to a single piston, it
performs a motion away from the valve
plate(oil sucking process) within 180
degrees, and makes a motion towards the
valve plate(or oil discharging process) in
the rest of 180 degrees. When the swash
plate has a tilting angle of zero, the piston
45070RG06
makes no stroke and discharges no oil.
2-9
2) REGULATOR
Regulator consists of the negative flow control, total horse power control and power shift control
function.
Delivery flow, Q
control in which the delivery flow Q
decreases as the pilot pressure Pi rises.
With this mechanism, when the pilot
pressure corresponding to the flow
required for the work is commanded, the
pump discharges the required flow only,
and so it does not consume the power Pilot pressure, Pi
uselessly.
2-10
① Flow reducing function
45070RG07
As the pilot pressure Pi rises, the pilot piston(643) moves to the right to a position where the force of the
pilot spring(646) balances with the hydraulic force.
The groove(A) in the pilot piston is fitted with the pin(875) that is fixed to lever 2(613). Therefore, when
the pilot piston moves, lever 2 rotates around the fulcrum of point B [Fixed by the fulcrum plug(614) and
pin(875)]. Since the large hole section(C) of lever 2 contains a protruding pin(897) fixed to the feedback
lever(611), the pin(897) moves to the right as lever 2 rotates. Since the opposing-flat section(D) of the
feedback lever is fitted with the pin(548) fixed by the tilting pin(531) that swings the swash plate, the
feedback lever rotates around the fulcrum of point D, as the pin(897) moves.
Since the feedback lever is connected with the spool(652) via the pin(874), the spool moves to the right.
The movement of the spool causes the delivery pressure P1 to connect to port CL through the spool
and to be admitted to the large diameter section of the servo piston. The delivery pressure P1 that is
constantly admitted to the small diameter section of the servo piston moves the servo piston to the right
due to the area difference, resulting in decrease of the tilting angle.
When the servo piston moves to the right, point D also moves to the right. The spool is fitted with the
return spring(654) and is tensioned to the left at all times, and so the pin(897) is pressed against the
large hole section(C) of lever 2.
Therefore, as point D moves, the feedback lever rotates around the fulcrum of point C, and the spool is
shifted to the left. This causes the opening between the sleeve(651) and spool(652) to close slowly,
and the servo piston comes to a complete stop when it closes completely.
2-11
② Flow increasing function
45070RG08
As the pilot pressure Pi decreases, the pilot piston(643) moves to the left by the action of the pilot
spring(646) and causes lever 2(613) to rotate around the fulcrum of point B. Since the pin(897) is
pressed against the large hole section(C) of lever 2 by the action of the return spring(654) via the
spool(652), pin(874), and feedback lever(611), the feedback lever rotates around the fulcrum of
point D as lever 2 rotates, and shifts the spool to the left. Port CL opens a way to the tank port as
the spool moves. This deprives the large diameter section of the servo piston of pressure, and
shifts the servo piston to the left by the discharge pressure P1 in the small diameter section,
resulting in an increase in the flow rate.
As the servo piston moves, point D also moves to the left, the feedback lever rotates around the
fulcrum of point C, and the spool moves to the right till the opening between the spool and sleeve is
closed.
2-12
③ Adjustment of flow control characteristic
The flow control characteristic can be
adjusted with the adjusting screw.
Adjust it by loosening the hexagon nut 801
(801) and by tightening(or loosening) the 924
hexagonal socket head screw(924).
Tightening the screw shifts the control
chart to the right as shown in the figure.
Delivery flow, Q
amount
Pilot pressure, Pi
2-13
(2) Total horsepower control
The regulator decreases the pump tilting
angle(delivery flow) automatically to limit
the input torque within a certain value with
Delivery flow, Q
a rise in the delivery pressure P1 of the
self pump and the delivery pressure P2 of
the companion pump.
(The input horsepower is constant when
the speed is constant.)
Since the regulator is of the simultaneous Delivery pressure, (P1+P2)
total horsepower type that operates by the
sum of load pressures of the two pumps
in the tandem double-pump system, the
prime mover is automatically prevented
from being overloaded, irrespective of the
load condition of the two pumps, when
horsepower control is under way.
Since this regulator is of the simultaneous
total horsepower type, it controls the tilting
angles(displacement volumes) of the two
pumps to the same value as represented
by the following equation :
Tin = P1×q/2Л + P2×q/2Л
= (P1+P2)×q/2Л
The horsepower control function is the
same as the flow control function and is
summarized in the following.(For detailed
behaviors of respective parts, refer to the
section of flow control).
2-14
① Overload preventive function
45070RG09
When the self pump delivery pressure P1 or the companion pump delivery pressure P2 rises, it
acts on the stepped part of the compensating piston(621). It presses the compensating rod(623)
to the right till the force of the outer spring(625) and inner spring(626) balances with the hydraulic
force. The movement of the compensating rod is transmitted to lever 1(612) via pin(875).
Lever 1 rotates around the pin(875) (E) fixed to the casing(601).
Since the large hole section(F) of lever 1 contains a protruding pin(897) fixed to the feedback
lever(611), the feedback lever rotates around the fulcrum of point D as lever 1 rotates, and then
the spool(652) is shifted to the right. As the spool moves, the delivery pressure P1 is admitted to
the large diameter section of the servo piston via port CL, causes the servo piston move to the
right, reduces the pump delivery, flow rate, and prevents the prime mover from being overloaded.
The movement of the servo piston is transmitted to the feedback lever via point D. Then the
feedback lever rotates around the fulcrum of point F and the spool is shifted to the left. The
spool moves till the opening between the spool(652) and sleeve(651) is closed.
2-15
② Flow reset function
45070RG10
As the self pump delivery pressure P1 or the companion pump delivery pressure P2 decreases,
the compensating rod(623) is pushed back by the action of the springs(625 & 626) to rotate lever
1(612) around point E. Rotating of lever 1 causes the feedback lever(611) to rotate around the
fulcrum of point D and then the spool(652) to move to the left. As a result, port CL opens a way
to the tank port.
This causes the servo piston to move to the left and the pump's delivery rate to increase.
The movement of the servo piston is transmitted to the spool by the action of the feedback
mechanism to move it till the opening between the spool and sleeve is closed.
2-16
③ Low tilting angle(low flow) command preferential function
As mentioned above, flow control and horsepower control tilting angle commands are
transmitted to the feedback lever and spool via the large-hole sections(C & F) of levers 1 and 2.
However, since sections C and F have the pins(Ø4) protruding from the large hole(Ø8), only the
lever lessening the tilting angle contacts the pin(897) ; the hole(Ø8) in the lever of a larger tilting
angle command is freed without contacting the pin(897). Such a mechanical selection method
permits preference of the lower tilting angle command of the flow control and horsepower
control.
④ Adjustment of input horsepower
Since the regulator is of total cumulative horsepower type, adjust the adjusting screws of both
the front and rear pumps, when changing the horsepower set values. The pressure change
values by adjustment are based on two pumps pressurized at the same time, and the values will
be doubled when only one pump is loaded.
Speed
Tightening Compens- Input torque
amount of ating control change
adjusting starting amount
Delivery flow, Q
screw(C) pressure
(628) change
amount
2-17
b. Adjustment of inner spring
626
Adjust it by loosening the hexagon nut
(801) and by tightening(or loosening)
the adjusting screw QI(925).
Tightening the screw increases the flow 801
and then the input horsepower as
925
shown in the figure.
※ Adjusting valves are shown in table.
Delivery flow, Q
(min -1) (Turn) (kgf/cm2) (kgf·m)
2-18
(3) Power shift control
45070RG11
2-19
(4) Adjustment of maximum and minimum flows
① Adjustment of maximum flow
Adjust it by loosening the hexagon
nut(806) and by tightening(or loosening)
the set screw(953).
The maximum flow only is adjusted without
changing other control characteristics.
45070RG12
Delivery flow, Q
amount of amount
adjusting screw
(953)
Speed
Tightening Flow change
amount of amount
adjusting screw
(954)
2-20
GROUP 1 PUMP DEVICE(#0464~)
1. STRUCTURE
The pump device consists of main pump, regulator.
Pi1 Pm1 Psv2
a5
(a1) (a2)
a1
a4
Psv1 PB Pi2
(a1)
Dr3
Dr1 PB
Dr2 A1 A2
Dr4
(a2)
a2
B1
Front pump Port block Rear pump
470072MP01
a4 Psv1 A1 a1 a2 A2 Psv2 a5
2-20-1
1) MAIN PUMP(1/2)
The main pump consists of two piston pumps(front & rear) and valve block.
789 732 532 214 531,548 724 702 792 534 719 901 492 130 706 954 468,728 151 152 113 263 406
535
808
953
886
717
251
406
824
111
774
261
127
710
123
401 490 212 211 153 156 157 490 313 311 124 114 719 466,725 312 885 314 012 271 402
492
470072MP02
2-20-2
2) FRONT REGULATOR(1/2)
Hydraulic circuit
B
Pm
801
641
SECTION B-B
Psv
470072RG01
466 Pi
755 Pm Port Port name Port size
2-20-3
FRONT REGULATOR(2/2)
655 734 653 654 836 651 652 601 624 629 630 628
641
814
801
C
925
898
631
627
732
732
733
622
SECTION A-A
470072RG02
2-20-4
3) REAR REGULATOR(1/2)
470072RG03
2-20-5
REAR REGULATOR(2/2)
655 734 653 654 836 651 652 601 624 629 630 628
641
814
801
C
925
898
631
627
732
732
733
622
SECTION A-A
470072RG02
2-20-6
4) GEAR PUMP
Dr Dr
B A
G G
12 7 6 8,9
16
Dr
3
A 5
B
10,11
14,15
G
Hydraulic circuit
2 4 13
470072GP01
2-20-7
2. FUNCTION
1) MAIN PUMP
The pumps may classified roughly into the rotary group performing a rotary motion and working as
the major part of the whole pump function: the swash plate group that varies the delivery rates: and
the valve cover group that changes over oil suction and discharge.
2-7 (210-7)
2-20-8
(3) Valve cover group
The valve cover group consists of valve
cover(F, 311), valve cover(R, 312), valve
plate(313, 314), spline coupling(114),
booster(130) and valve plate pin(885).
The valve plate having two melon-shaped
ports is fixed to the valve cover and feeds
and collects oil to and from the cylinder
cover.
314
The oil changed over by the valve plate is 312
connected to an external pipeline by way
of the valve cover. 130
Now, if the drive shaft is driven by a prime 114
885
mover(electric motor, engine, etc), it 311
rotates the cylinder block via a spline
linkage at the same time. If the swash
plate is tilted as in Fig(previous page) the
pistons arranged in the cylinder block
make a reciprocating motion with respect
885
to the cylinder block, while they revolve 313
with the cylinder block.
If you pay attention to a single piston, it
performs a motion away from the valve
plate(oil sucking process) within 180
degrees, and makes a motion towards the
valve plate(or oil discharging process) in
the rest of 180 degrees. When the swash
plate has a tilting angle of zero, the piston
36072MP03
makes no stroke and discharges no oil.
2-20-9
2) REGULATOR
Regulator consists of the negative flow control, total horse power control and power shift control
function.
Delivery flow, Q
control in which the delivery flow Q
decreases as the pilot pressure Pi rises.
With this mechanism, when the pilot
pressure corresponding to the flow
required for the work is commanded, the
pump discharges the required flow only,
and so it does not consume the power Pilot pressure, Pi
uselessly.
2-20-10
① Flow reducing function
P1 CL
B(E)
874
897
C
A
875
611
2-10
As the pilot pressure Pi rises, the pilot piston(643) moves to the right to a position where the force of the
pilot spring(646) balances with the hydraulic force.
The groove(A) in the pilot piston is fitted with the pin(875) that is fixed to lever 2(613). Therefore, when
the pilot piston moves, lever 2 rotates around the fulcrum of point B [Fixed by the fulcrum plug(614) and
pin(875)]. Since the large hole section(C) of lever 2 contains a protruding pin(897) fixed to the feedback
lever(611), the pin(897) moves to the right as lever 2 rotates. Since the opposing-flat section(D) of the
feedback lever is fitted with the pin(548) fixed by the tilting pin(531) that swings the swash plate, the
feedback lever rotates around the fulcrum of point D, as the pin(897) moves.
Since the feedback lever is connected with the spool(652) via the pin(874), the spool moves to the right.
The movement of the spool causes the delivery pressure P1 to connect to port CL through the spool
and to be admitted to the large diameter section of the servo piston. The delivery pressure P1 that is
constantly admitted to the small diameter section of the servo piston moves the servo piston to the right
due to the area difference, resulting in decrease of the tilting angle.
When the servo piston moves to the right, point D also moves to the right. The spool is fitted with the
return spring(654) and is tensioned to the left at all times, and so the pin(897) is pressed against the
large hole section(C) of lever 2.
Therefore, as point D moves, the feedback lever rotates around the fulcrum of point C, and the spool is
shifted to the left. This causes the opening between the sleeve(651) and spool(652) to close slowly,
and the servo piston comes to a complete stop when it closes completely.
2-20-11
② Flow increasing function
P1 CL
B(E)
874
897
C
875
611
Small diameter
Servo piston D 548 chamber
Large diameter
chamber
531
2-11
As the pilot pressure Pi decreases, the pilot piston(643) moves to the left by the action of the pilot
spring(646) and causes lever 2(613) to rotate around the fulcrum of point B. Since the pin(897) is
pressed against the large hole section(C) of lever 2 by the action of the return spring(654) via the
spool(652), pin(874), and feedback lever(611), the feedback lever rotates around the fulcrum of
point D as lever 2 rotates, and shifts the spool to the left. Port CL opens a way to the tank port as
the spool moves. This deprives the large diameter section of the servo piston of pressure, and
shifts the servo piston to the left by the discharge pressure P1 in the small diameter section,
resulting in an increase in the flow rate.
As the servo piston moves, point D also moves to the left, the feedback lever rotates around the
fulcrum of point C, and the spool moves to the right till the opening between the spool and sleeve is
closed.
2-20-12
③ Adjustment of flow control characteristic
The flow control characteristic can be
adjusted with the adjusting screw.
Adjust it by loosening the hexagon nut 801
(801) and by tightening(or loosening) the 924
hexagonal socket head screw(924).
Tightening the screw shifts the control
chart to the right as shown in the figure.
※ Adjusting values are shown in table.
Adjustment of flow control
characteristic 2-12 (210-7)
Speed
Tightening Flow Flow
amount of control change
adjusting starting amount
screw(924) pressure
Delivery flow, Q
change
amount
Pilot pressure, Pi
2-20-13
(2) Total horsepower control
The regulator decreases the pump tilting
angle(delivery flow) automatically to limit
the input torque within a certain value with
Delivery flow, Q
a rise in the delivery pressure P1 of the
self pump and the delivery pressure P2 of
the companion pump.
(The input horsepower is constant when
the speed is constant.)
Since the regulator is of the simultaneous Delivery pressure, (P1+P2)
total horsepower type that operates by the
sum of load pressures of the two pumps
in the tandem double-pump system, the
prime mover is automatically prevented
from being overloaded, irrespective of the
load condition of the two pumps, when
horsepower control is under way.
Since this regulator is of the simultaneous
total horsepower type, it controls the tilting
angles(displacement volumes) of the two
pumps to the same value as represented
by the following equation :
Tin = P1×q/2Л + P2×q/2Л
= (P1+P2)×q/2Л
The horsepower control function is the
same as the flow control function and is
summarized in the following.(For detailed
behaviors of respective parts, refer to the
section of flow control).
2-20-14
① Overload preventive function
45070RG09
When the self pump delivery pressure P1 or the companion pump delivery pressure P2 rises, it
acts on the stepped part of the compensating piston(621). It presses the compensating rod(623)
to the right till the force of the outer spring(625) and inner spring(626) balances with the hydraulic
force. The movement of the compensating rod is transmitted to lever 1(612) via pin(875).
Lever 1 rotates around the pin(875) (E) fixed to the casing(601).
Since the large hole section(F) of lever 1 contains a protruding pin(897) fixed to the feedback
lever(611), the feedback lever rotates around the fulcrum of point D as lever 1 rotates, and then
the spool(652) is shifted to the right. As the spool moves, the delivery pressure P1 is admitted to
the large diameter section of the servo piston via port CL, causes the servo piston move to the
right, reduces the pump delivery, flow rate, and prevents the prime mover from being overloaded.
The movement of the servo piston is transmitted to the feedback lever via point D. Then the
feedback lever rotates around the fulcrum of point F and the spool is shifted to the left. The
spool moves till the opening between the spool(652) and sleeve(651) is closed.
2-20-15
② Flow reset function
45070RG10
As the self pump delivery pressure P1 or the companion pump delivery pressure P2 decreases,
the compensating rod(623) is pushed back by the action of the springs(625 & 626) to rotate lever
1(612) around point E. Rotating of lever 1 causes the feedback lever(611) to rotate around the
fulcrum of point D and then the spool(652) to move to the left. As a result, port CL opens a way
to the tank port.
This causes the servo piston to move to the left and the pump's delivery rate to increase.
The movement of the servo piston is transmitted to the spool by the action of the feedback
mechanism to move it till the opening between the spool and sleeve is closed.
2-20-16
③ Low tilting angle(low flow) command preferential function
As mentioned above, flow control and horsepower control tilting angle commands are
transmitted to the feedback lever and spool via the large-hole sections(C & F) of levers 1 and 2.
However, since sections C and F have the pins(Ø4) protruding from the large hole(Ø8), only the
lever lessening the tilting angle contacts the pin(897) ; the hole(Ø8) in the lever of a larger tilting
angle command is freed without contacting the pin(897). Such a mechanical selection method
permits preference of the lower tilting angle command of the flow control and horsepower
control.
④ Adjustment of input horsepower
Since the regulator is of total cumulative horsepower type, adjust the adjusting screws of both
the front and rear pumps, when changing the horsepower set values. The pressure change
values by adjustment are based on two pumps pressurized at the same time, and the values will
be doubled when only one pump is loaded.
Speed
Tightening Compens- Input torque
amount of ating control change
adjusting starting amount
Delivery flow, Q
screw(C) pressure
(628) change
amount
2-20-17
b. Adjustment of inner spring
626
Adjust it by loosening the hexagon nut
(801) and by tightening(or loosening)
the adjusting screw QI(925).
Tightening the screw increases the flow 801
and then the input horsepower as
925
shown in the figure.
※ Adjusting valves are shown in table.
Delivery flow, Q
(min -1) (Turn) (lpm) (kgf·m)
2-20-18
(3) Power shift control
45070RG11
2-20-19
(4) Adjustment of maximum and minimum flows
808
① Adjustment of maximum flow
Adjust it by loosening the hexagon 954
nut(808) and by tightening(or loosening)
the set screw(954).
The maximum flow only is adjusted without
changing other control characteristics.
2-19(1)
Delivery flow, Q
amount of amount
adjusting screw
(954)
Speed
Tightening Flow change
amount of amount
adjusting screw
(953)
2-20-20
(5) Qmax cut control 647
The regulator regulates the maximum 648
delivery flow by inputting the pilot pressure 723
Pm. Since this is a 2-position control 642 438
method, the maximum delivery flow may 801
be switched in two steps by turning on/off 801
924
the pilot pressure Pm.(The maximum
control flow cannot be controlled in 641 730 643 708 644 645 646 728
intermediate level.)
① Functional explanation 2-4
Delivery flow, Q
admitted to the lefthand side of the piston Pm
QMC(648). The piston QMC moves the
stopper(647) and pilot piston(643) to the
right, overcoming the force of the pilot
spring(646), thereby reducing the
delivery flow of the pump.
Pilot pressure, Pi
Since the adjusting screw QMC(642) is
provided with a flange, the piston QMC
stops upon contact with the flange, and
the position of the pilot piston at this time
determines the maximum flow of the
pump.
② Adjustment of Qmax cut flow
Adjust it by loosening the hexagon
nut(801) and by tightening(or loosening)
Delivery flow, Q
Pilot pressure, Pi
2-20-21