Electrostatic Discharge

Measurement & Control Instruments Catalog

An Advanced Energy Company


www.trekinc.com
Trek ESD Measurement & Control Instruments - Table of Contents
AC Feedback Electrostatic Voltmeters Model 520-1, Model 876..... p.1
AC Feedback Electrostatic Voltmeters Model 523-1, Model 884..... p.1
DC Feedback Electrostatic Voltmeter / USB Model 541A-1 .................................. p.2
AC Feedback Electrostatic Voltmeter / USB Model 542A-1 .................................. p.2
Application Software Model 541A, 542A...................... p.3
Hand-Held Contacting Electrostatic Voltmeter Model 821HH..................................... p.3
Charged Plate Monitor Model 156A.......................................... p.4
Charged Plate Monitor Model 157 ............................................. p.4
Charged Plate Monitor Model 158A.......................................... p.5
ESD Audit Kit Model 511/1501.............................. p.6
Electrostatic Field Meter Model 511 ............................................ p.6
Surface Resistance Meter Model 1501 ......................................... p.6
Surface Resistance / Volume Resistance Meter Model 152-1........................................ p.7
High Sensitivity ESD Event Detector Model 901HS ................................... p.7
Nozzle Ionizer Model 950 ............................................ p.8
Electrostatic Voltmeters – Measurement Distance & Measurement Area .................................. p.10

Theory of Operation – DC Feedback Electrostatic Voltmeter ....................................................... p.11

Theory of Operation – AC Feedback Electrostatic Voltmeter ....................................................... p.11

Additional Information – Sales & Service ............................................................................. Back Cover

www.trekinc.com
Model 520-1, Model 876  AC Feedback Electrostatic Voltmeters

Features
• Non-contacting voltage measurement
• No need to maintain fixed spacing; accurate at a wide range of spacings
• Portable (battery operated)
• Good for difficult-to-reach locations (Model 876 has probe-on-cable design)
• Drift-free operation in ionized environments
• Low cost

Applications
Static charge measurement for LCD, semiconductor devices, MR heads.
Monitor electrostatic levels in IC production processes. Surface potential
measurement of silicon wafers, films and papers. Materials testing. Model 520-1
Standard static charge measurements.

Specifications
Measurement Range....................................................................... 0 to ±2kV
Voltage Display............................................................................ 0 to ±1999V
Voltage Resolution..................................................................................... 1V Model 876
Probe-to-Surface Separation . ....................................... Range of 5 to 25mm
Accuracy............................................................................... ±5% (Full Scale)
Speed of Response..............................................................................400ms
Model 520-2 (with analog output function)
Operating Conditions
Output Ratio................................................. 1/1000 of the measured voltage
Temperature...............................................................................15 to 35°C
Speed of Response . .............................................................................25ms
Relative Humidity..............................................to 85%RH, noncondensing
Output Terminal . ......................................................................... 1.3mm jack
Power Supply...............................................................9V alkaline battery (1)
Dimensions................5.9cm W x 3.1cm H x 14.6cm L (without cable sensor)
Weight.....................................................................................................185g

Model 523-1, Model 884  AC Feedback Electrostatic Voltmeters

Features
• Non-contacting voltage measurement
• No need to maintain fixed spacing; accurate at a wide range of spacings
• Portable (battery operated)
• Good for difficult-to-reach locations (Model 884 has probe-on-cable design)
• Drift-free operation in ionized environments
• Low cost

Applications
Static charge measurement for LCD, semiconductor devices. Monitor
electrostatic levels in IC production processes. Surface potential
measurement of silicon wafers, films and papers. Materials testing.
Standard static charge measurements. Model 523-1

Specifications
Measurement Range..................................................................... 0 to ±20kV
Voltage Display......................................................................... 0 to ±19.99kV
Model 884
Voltage Resolution................................................................................... 10V
Probe-to-Surface Separation........................................ Range of 30 to 60mm
Accuracy............................................................................... ±5% (Full Scale) Power Supply...............................................................9V alkaline battery (1)
Speed of Response..............................................................................400ms Dimensions . .............5.9cm W x 3.1cm H x 14.6cm L (without cable sensor)
Operating Conditions Weight.....................................................................................................200g
Temperature...............................................................................15 to 35°C
Relative Humidity..............................................to 85%RH, noncondensing

www.trekinc.com 1
Model 541A-1  DC Feedback Electrostatic Voltmeter - USB Supported

Features
• USB or RS-232 serial port enables computer-based control & monitoring
• Visual and audible alarms
• LCD screen displays present voltage and offers peak data hold function
• Very small probe-to-test surface distances, excellent spot resolution
and accuracy
• Chopper probe is DC stable with/without incident air ion flow

Applications
Static charge measurement of semiconductor devices. Monitor electrostatic
levels in IC production processes, semiconductor production processes
and various production lines.

Specifications
Measurement Range.......................... 0 to ±1kV (Model 541A-2: 0 to ±100V) Please specify probe type(s) when
Output Monitor ordering Model 541A-1 or 541A-2.
Output Voltage.................................................................0 to ±10V (1/100)
Output Current............................................................................ 4 to 20mA
Probe-to-Surface Separation.......................................... Range of 1 to 10mm
Probes for Model 541A....................................... Model 541PR-S (side view)
Accuracy.................................................................±1% (Full Scale) or better
Model 541PR-E (end view)
Speed of Response........................................ 50ms for 1kV step (10 to 90%)
Model 541P-S (side view)
Operating Conditions
Vacuum application probes also available
Temperature...............................................................................15 to 35°C
Walking Test Adapter........ For analysis of charge levels on the human body
Relative Humidity...........................................5 to 85%RH, noncondensing
Compliant with ANSI/ESD STM97.2; IEC 61340-4-5
Power Supply............................................................ Line to 15V DC adapter
Dimensions............................................... 15.2cm W x 10.2cm H x 21.6cm D
Weight.....................................................................................................770g

Model 542A-1  AC Feedback Electrostatic Voltmeter - USB Supported

Features
• USB or RS-232 serial port enables computer-based control & monitoring
• Visual and audible alarms
• LCD screen displays present voltage and offers peak data hold function
• Drift-free measurements
• Chopper probe is DC stable with/without incident air ion flow
• Voltage output monitor for remote monitoring or control

Applications
Static charge measurement of plastic and polymer film. Monitor electrostatic
levels in LCD production processes and for various production lines.

Specifications
Measurement Range........................ 0 to ±10kV (Model 542A-2: 0 to ±20kV)
Output Monitor
Please specify probe type(s) when
Output Voltage....................... 0 to ±10V (1/1000); Model 542A-2: (1/2000) ordering Model 542A-1 or 542A-2.
Output Current............................................................................ 4 to 20mA
Probe-to-Surface Separation........................................ Range of 15 to 30mm
(Model 542A-2: 30 to 60mm)
Accuracy.............................................. ±5% (of Reading); ±0.2% (Full Scale) Probes for Model 542A...........................................Model 542P-S (side view)
Speed of Response........................................ 50ms for 1kV step (10 to 90%) Model 542P-45D (45 degree angle)
Operating Conditions Vacuum application probes also available
Temperature...............................................................................15 to 35°C Walking Test Adapter........ For analysis of charge levels on the human body
Relative Humidity...........................................5 to 85%RH, noncondensing In support of EN 1815; Assessment of Static Electrical
Power Supply............................................................ Line to 15V DC adapter Propensity on Resilient and Textile Floor Coverings
Dimensions............................................... 15.2cm W x 10.2cm H x 21.6cm D
Weight.....................................................................................................770g
2 www.trekinc.com
Model 541A, 542A   Application Software

Explanation of the Screen


1. Voltage display (V)............................................ Display measured voltage 1
2. Positive (+) threshold (V).........................................................Set the level
3. Negative (-) threshold (V)........................................................Set the level
4
4. Positive (+) peak value (V)....................... Display maximum voltage value
2 3
of positive (+) side
5. Negative (-) peak value (V)....................... Display maximum voltage value 4
of negative (-) side 5
6. Menu screen......................Display the screen setting of the measurement
10 5
7. Data save...........................................................Save measurement value 6
8
8. Reset.........................................................................Reset the peak value
7
9. Exit..........................................................................Terminate the software
9
10. Length of time . ......................Select the length of time for displaying the
measurement value (storage time)

To enhance the utility of Model 541A and Model 542A, Trek provides Trek’s software thereby enables touchscreen setting of threshold values
application software (available for download at www.trekinc.com) and a USB and preservation of data. The data can be viewed graphically (screen shot
or RS-232 serial port on both models for interfacing with a Windows® PC. above), in real time. Other PC-friendly adjustments include threshold
setting, alarm ON/OFF, and storage time.

Model 821HH   Infinitron® Hand-Held Contacting Electrostatic Voltmeter

Features
• Portable, battery-operated, compact design
• Trek contacting technology enables precise surface voltage
measurements
• Measure conductive and insulative objects/surfaces with virtually zero
charge transfer to the measurement probe
• Save test data to internal memory
• Data graphing capabilities (via connection with PC)

Specifications
Input Characteristics......................... Resistance >1014Ω, Capacitance <10-14F
Measurement Range……....................................... 0 to ±2kV DC or peak AC
Bandwidth.....................................................................................1kHz (-3dB)
Accuracy............................................................................... ±1% (Full Scale)
Operating Conditions
Temperature...............................................................................15 to 35°C
Relative Humidity...........................................5 to 75%RH, noncondensing
Power Supply.....................................Internal NiMH battery (approx. 8 hours
continuous usage from a full charge) or external
15V @ 1A supply/charger for line operation
Dimensions…………………...................... 14.0cm W x 24.0cm H x 5.25cm D
Weight..................................................................... 1.13kg (includes battery)

www.trekinc.com 3
Model 156A  Charged Plate Monitor

Features
• Compliance to IEC 61340-5-1 and ANSI/ESD STM3.1
• Mode of operation is easy to select via three-position toggle switch
• Standard ion collection plate, 6” x 6”

Specifications
Measurement Range.......................................... 0 to ±1100V DC or peak AC
Small Signal Bandwidth................................................................1kHz (-3dB)
Output Monitor........................................................ 1/200 of the plate voltage
Accuracy . ......................................................................... ±0.1% (Full Scale)
Offset Voltage...................................................................................... ±10mV
Output Noise ................................................................................. 10mV rms Please specify plate type(s) when
Operating Conditions ordering Model 156A
Temperature.................................................................................5 to 35°C
Relative Humidity..............................................to 80%RH, noncondensing Dimensions................................................. 31.8cm W x 8.3cm H x 28.0cm D
Power Supply..........................Built-in rechargeable battery (approx. 8 hours Weight....................................................................................................2.0kg
of continuous usage from a full charge) or by using a recharge/operating
AC adapter. AC power adapter for all global areas is available.

Model 157  Charged Plate Monitor

Features
• Compliance to IEC 61340-5-1 and ANSI/ESD STM3.1
• Store & retrieve data as data points or graphs; internal memory
• USB connection (to PC) enables real time data
• Connect to the optional Thermohygrometer Kit (Omega Model HH331)
• Bar code wand also available

Specifications
Measurement Range . ....................................... 0 to ±1020V DC or peak AC
Large Signal Bandwidth............................................................... 80Hz (-3dB)
Monitor Output........................................................ 1/200 of the plate voltage
Accuracy............................................................................ ±0.1% (Full Scale) Please specify plate type(s) when
Offset Voltage............................................................................ under ±10mV ordering Model 157
Output Noise ................................................................................. 10mV rms
Operating Conditions
Temperature.................................................................................5 to 35°C Dimensions............................................... 25.4cm W x 10.2cm H x 24.1cm D
Relative Humidity..............................................to 80%RH, noncondensing Weight....................................................................................................2.0kg
Power Supply ....................Built-in rechargeable battery (approx. 8 hours of
continuous usage from a full charge) or by using a recharge/operating
AC adapter. AC power adapter for all global areas is available.

Ion Collecting Plates (can be used with Model 156A and 157)
Standard Charged Plate, 15cm x 15cm (6” x 6”) - Model 156AP-C150x150-R3M**; Standard Charged Plate, 25mm x 25mm (1” x 1”) - Model 156P-C25x25-S3M; High Temperature Charged Plate,
15cm x 15cm (6” x 6”) - Model 156P-HT-150x150-R3M**; High Temperature Charged Plate, 25mm x 25mm (1” x 1”) - Model PD04002AP
.** Complies with IEC 61340 Standard Note: Other sizes and shapes of charge plates are available. Deionized water probes are also available (PM08035)

Deionized Water Probe

Standard Charged Plate, 6” x 6”

High Temperature Charged Plate, 6" x 6"


Standard Charged Plate, 1” x 1” High Temperature Charged Plate, 1" x 1"

4 www.trekinc.com
Model 158A   Charged Plate Monitor

Trek Model 158A Charged Plate Monitor is the premier instrument


to evaluate the performance of air ionization systems. Its design
includes a color graphics display for viewing of discharge waveforms
and offset voltage in the time domain and the ability to store test data
and waveforms for hundreds of ionizer tests. This unit employs Trek’s
patented voltage-follower technique to provide accuracy, stability and
bandwidth well beyond the performance capabilities of field meter
technology.

Features
• Compliance to IEC 61340-5-1 and ANSI/ESD STM3.1
• User-friendly compact design
• Superior data collection and storage capability
• Large LCD color graphic display
• Navigate via touch screen or function keys
• Standard ion collecting plates available (see below) Please specify plate type(s) when ordering Model 158A.
• Operate in Float Mode, (+) Decay Mode, or (-) Decay Mode A Model 158A Charged Plate Monitor Kit is also available.
See details below.
• Programmable voltage balance and (+) and (-) discharge time
• Performs float voltage and discharge time EOS/ESD measurements
• Allows multiple operational and programing options
• Can be pre-set to perform automated tests
• Can store/retrieve previously defined test parameters
• Test data can be saved for future reference/retrieval
• Long battery life
• USB port enables data transfer
• Optional barcode scanner with bluetooth technology

Specifications
Measurement Range . ....................................... 0 to ±1100V DC or peak AC Power Supply......................Built-in rechargeable battery (approx. 6 hours of
Large Signal Bandwidth............................................................... 80Hz (-3dB) continuous usage from a full charge); can also be
Monitor Output........................................................ 1/200 of the plate voltage operated using the supplied AC adapter.
Accuracy............................................................................ ±0.1% (Full Scale) Dimensions................................................. 22.6cm W x 5.3cm H x 18.7cm D
Offset Voltage...................................................................................... ±10mV Weight....................................................................................................2.2kg
Output Noise.................................................................................. 10mV rms2
Operating Conditions
Temperature.................................................................................5 to 35°C
Relative Humidity.............................................to 80%RH, non-condensing

Ion Collecting Plates


Standard ion collecting plates are ordered separately; standard 6” x 6” plate and standard 1” x 1” plate are available.
Refer to relevant photos on prior page.

Model 158A Charged Plate Monitor Kit


This kit includes Model 158A charged plate monitor, standard 6” x 6” collecting plate, standard 1” x 1” collecting plate, charged
.plate handle, walking test adapter assembly, mini-tripod, and custom carrying case.

www.trekinc.com 5
Model 511/1501   ESD Audit Kit

Trek’s Model 511/1501 ESD Audit Kit includes the Model 511 Ionizer Kit
(electrostatic field meter, charger, and charge plate) and Model 1501 (surface
resistance meter) in a compact carrying case. Please refer to specifications
below. Most items can be ordered individually. Refer to details below.

The carrying case and all of its contents are


shown (far left). The kit as packaged for delivery
is also shown (near left). Orders in the USA
include ground plug adaptor, AC receptacle
tester, and 2.75W charger/USB adaptor.
(below).

Model 511   Electrostatic Field Meter


USA only

Features
The Model 511 Ionizer Kit includes
• Switch selectable measurement range the Model 511 electrostatic field
• Hand-held, portable, non-contacting meter (left) and the related charger
• Chopper-stabilized technology and charge plate (below).
• Reliable in ionized or non-ionized environments All items can be ordered individually.
• Complies with ANSI/ESD SP3.3

Specifications
Measurement Range (per inch)……..................0 to ±2kV…OR… 0 to ±20kV
Measurement Accuracy
Voltage Monitor Output.......................better than ±5% of reading, ±10mV
Voltage Display...............................better than ±5% of reading, ±2 counts
Operating Conditions
Temperature..............................................................................10 to 30°C
Relative Humidity............................................to 80%RH, non-condensing Dimensions....................................................2.4cm H x 7.0cm W x 12.6cm L
Power Supply............................................... 9V alkaline battery (1), included Weight...............................................................................140g (with battery)

Model 1501   Surface Resistance Meter

Features
• Auto-ranging
• Lightweight, hand-held
• Displayed values can be stored in internal memory
• Records temperature and relative humidity
• Built-in electrodes with conductive rubber
• Appropriate electrodes can be externally connected for tests
(IEC 61340: -4-1, -2-3, -4-5; ANSI/ESD: S4.1-2006;
ANSI/ESD STM: 11.11-2006, 11.12-2007, 11.13-2004, 12.1-2006,
97.1-2006)

Specifications
Measuring Range......................................................................... 103Ω to 1012Ω
Display Range ………1x10z to 9x10z where z = measuring range exponent
Accuracy ……………10% to 25% of reading (depends on measuring range)
Operating Conditions Power Supply............................ Rechargeable lithium battery, 3.6V 900mAh
Temperature.............................................................................. -5 to 40°C Dimensions................................................... 14.5cm H x 8.0cm W x 3.5cm D
Relative Humidity............................................to 75%RH, non-condensing Weight.....................................................................................................290g

6 www.trekinc.com
Model 152-1   Surface Resistance / Volume Resistance Meter

Features
• Accuracy, stability and repeatability in a lightweight, portable design
• Complies with IEC 61340-5-1 for Surface Resistance Measurements
• Complies with IEC 61340-2-3 for Volume Resistance Measurements
• Technique used to measure surface resistance and volume resistance
conforms to ANSI/ESD Association standards (STM2.1, 4.1, 7.1, 9.1,
11.11, 11.12, 12.1, 11.13, 97.1)
• Wide measurement ranges of 103 to 1013 Ω
• Variety of probes available (see photo at right)
Model 152P-CR-1........... Surface resistance/volume resistance (center top)
Model 152P-2P…….............Two-point surface resistance (center bottom)
Model 152BP-5P.............. Point-to-point surface resistance (lower right)
Model 152AP-3mm x 25.4mm………..Miniature resistance probe (pair)
Part CN 1K039..................................Walking test adapter kit (lower left)

Please specify probe type(s) when


Specifications ordering Model 152-1

Measurement Range..................................................................... 103 to 1013Ω Operating Conditions


(using probe 152BP-5P, 152P-2P, or 152P-CR-1) Temperature...............................................................................15 to 35°C
Test Voltage................ Select 10V or 100V (±2%) using the selection switch Relative Humidity...........................................5 to 80%RH, noncondensing
Power Supply...................Two 9V alkaline batteries provide approx. 6 hours Dimensions................................................. 10.0cm W x 18.0cm H x 4.4cm D
of power for portable operation. AC line adapter Weight........................................................................ 500g (includes battery)
available for all global areas.

Model 901HS   High-Sensitivity ESD Event Detector

Features
• Sensitive to ESD voltage levels as low as 10V at 50mm
• Well-suited for Charge Device Model (CDM) and discharge between
metallic electrodes
• ESD event detection conveyed through visual and audible alert systems
• Good for difficult-to-reach locations (antenna-on-cable design)
• Compact, lightweight design and highly accurate data
• Operates on four AA batteries; AC power adapter for continuous
• Alternate antenna for less sensitive detection (50V @ 90mm)

Specifications
Indicators…………............ Audible alarm and 5 color-coded LEDs to visually
indicate intensity
Alarm………………....................................Automatic or manual reset control
Dimensions................................................... 8.0cm W x 11.0cm H x 4.5cm D
Weight........................................................................ 500g (includes battery)

www.trekinc.com 7
Model 950   Nozzle Ionizer

The Model 950 is a nozzle type air ionizer which removes dust
contamination and eliminates static electricity by use of high pressure
ionized air flow. The compact nozzle body contains a built-in high-voltage
power supply and an abnormal operation detection/warning output circuit.
Model 950 is operated by connecting a compressed air supply and a 24V
power supply to the unit.

Using a high-frequency corona discharge, Model 950 enables the efficient


elimination of static electricity. Selection of specific nozzles (from a variety
of options, as shown on p.7) to transfer ionized air provides utility for Model
950 in a wide range of applications. The Model 950 uses an LED display
and contact output to indicate abnormal conditions. The high voltage supply
and ionizing electrode can be replaced easily through the back of the unit.
These features facilitate easy cleaning and maintenance at the production
line site, thereby reducing downtime. Please specify nozzle type(s) when ordering Model 950

Features
• Ultra-small compact body • Easy maintenance – built-in power supply with a replaceable emitter unit
• High voltage failure and emitter needle contamination detector function makes for easy cleaning and replacement
• Outputs a relay signal when abnormal operating conditions occur • Excellent ion balance
• Optional tubes allow transfer of ionized air to remote or difficult-to-reach • A wide range of optional nozzles and tubes for various applications
locations

How to replace or clean the discharge needle

LED Display (displays the information shown in the chart below) Rear of the unit showing
the discharge needle
access and the connector
for power input, output
signal, and failure alarm
output relay signal

Operating Conditions – LED Indicators


“Power” “H. V.” “C. C.” “Alarm”
Condition
Green LED Green LED Yellow LED Red LED

Normal Operation • •
H.V. Malfunction • •
Maintenance Needed
(clean the needle) • • •
H.V. Output Off •
Power Off

8 www.trekinc.com
Specifications
Discharge Method...................High-frequency AC corona discharge method Ozone Density....... 0.05ppm or less (at a distance of 300mm from air outlet)
Input Power Supply Voltage......................................................24V DC±10% Ion Balance......................................................±15V or less (0.05 to 0.5MPa)
Power....................................................................................................2.4VA Material . ................................................................................Enclosure: ABS
Air Purge-Operation Pressure................................................ 0.05 to 0.6MPa Cover: stainless steel
Dimensions..........................8.65cm D x 1.8cm W x 5.0cm H (main unit only) Discharge needle: tungsten
Weight................................................................Approx. 80g (main unit only) Air Piping Dimension...................................................................... 6mm O.D.
Operating Conditions
Temperature.................................................................................0 to 40°C
Relative Humidity.........................................15 to 65%RH, noncondensing

Model 950 Optional Parts (length, material type and part numbers as noted)

Seamless carrier pipe nozzle Bar nozzle Carrier tube nozzle


(950-C200 in photo) (950-200B in photo) (950-TT in photo)
100mm 950-C100 100mm 950-100B Teflon carrier tube nozzle 950-TT
200mm 950-C200 200mm 950-200B Silicon carrier tube nozzle 950-ST
300mm 950-C300 300mm 950-300B
400mm 950-C400
500mm 950-C500

Shower nozzle Flat nozzle AC Adapter (950-24VA in photo)


950-60S 950-F 950-24VA AC Adapter
(power supply + signal cable + grounding wire)
950-24V AC Adapter
(power supply only)

Model 950 Other Optional Parts (part numbers as noted) Bar nozzle L-type Pipe nozzle Mounting Frame
950-100BL 950-120PSP 950-FM
950-200BL

Main Unit Dimensions Mounting Frame Dimensions


7.5mm
22.5mm

50.0mm

50.0mm
14.5mm

10.5mm

18.0mm 24.7mm 86.5mm 24.7mm 71.5mm 15mm


80.5mm

111.2mm
7mm

www.trekinc.com 9
Electrostatic Voltmeters: Measurement Distance & Measurement Area

Model 520, 876 Model 523, 884


25 70

60
Measurement distance (mm) 20

Measurement distance (mm)


50
15
40

10 30

20
5
10

0
0
50 100 150 200 250 150 200 250 300 350 400
Measurement spot size diameter (mm) Measurement spot size diameter (mm)
10% error 5% error 10% error

Model 541 Model 542P-45D probe


7 50

Measurement distance (mm)


Measurement distance (mm)

40
5

30
4

3 20

2
10
1

0 0
10 14 18 22 26 80 100 120 140 160 180 200
Measurement spot size diameter (mm) Measurement spot size diameter (mm)

1% error 5% error 5% error 10% error

Figure 1. Spatial Resolution, Trek AC Feedback Figure 2. Spatial Resolution, Trek DC Feedback
Electrostatic Voltmeter (i.e. Model 520) Electrostatic Voltmeter (i.e. Model 541)

ø25mm d:5mm ø3mm d:1mm

ø50mm d:10mm

ø80mm d:15mm ø25mm d:5mm

ø120mm d:20mm

ø170mm d:25mm ø70mm d:10mm

Figure 3. Measurement Accuracy vs. Measurement Figure 4. Spot Resolution at Selected Distances
+100 Distance
3800S-2:1mm/ø5mm
Measurement Accuracy (%)

541PR-S:2mm/ø10mm
(measurement distance/
measurement spot diameter)
0

−100
0.0 10.0 20.0 30.0 40.0 520, 876:5mm/ø25mm
Measurement Distance (mm) 523, 884:30mm/ø150mm

Model 520 Typical Fieldmeter

10 www.trekinc.com
Theory of Operation – DC Feedback Electrostatic Voltmeter

Trek offers two types of technology in the company’s Electrostatic The DC Feedback Electrostatic Voltmeters use a well-known technology
Voltmeters. One product line utilizes DC feedback technology while that Trek has employed for over 45 years (diagram below). The design
the other product line is based on Trek’s novel approach to utilizes a field-nulling method where the body of the probe is driven to the
electrostatic measurement via patented AC feedback technology. voltage being measured. This provides very high accuracy and fast speed
of response. Since the probe is spaced relatively close to the surface
being measured (1-2 mm typical) it is capable of measuring very small
surface areas, with no arc over.

ESVM Theory of Operation


Figure 5. Theory of Operation – DC Feedback Electrostatic Voltmeter

Test Surface

Probe

Sensitive
Electrode

B
Phase
Sensitive
Demodulator A
Electro
High
Mechanical 99R
Voltage
Modulator Monitor
Amplifier
Output
C V out = V surface /100

R
Oscillator
M Digital
Panel
Meter
Vsurface

Theory of Operation – AC Feedback Electrostatic Voltmeter

The AC Feedback Electrostatic Voltmeters are


based on a unique design developed and Figure 6. Theory of Operation – AC Feedback Electrostatic Voltmeter
patented by TREK, INC. to address some of the
problems associated with electrostatic fieldmeter
technology. The AC feedback technology
(diagram at right) delivers accurate measurements
over a wide range of probe-to-surface spacings Sensor Electrode
without the need to generate high voltage. Measuring R
Compare this to fieldmeter technology which Surface C
requires a specific fixed spacing in order to V1
A1 V2 AC V FB
A2
provide useful measurements. In addition, the AC Amplifier
feedback electrostatic voltmeter can measure
AC Feedback
smaller surface areas than fieldmeters because
Trek’s technology allows the probe to be placed VM
closer to the surface. Oscillator

VS

For a complete technical description of the DC Feedback


Technology and AC Feedback Technology please
contact Trek.

www.trekinc.com 11
Notes

www.trekinc.com
Notes

www.trekinc.com
Trek Sales & Service

Warranty Pricing & Specifications


A ONE (1) YEAR Warranty applies to Trek’s products. TREK, Product pricing and specifications are subject to change.
INC. agrees to correct, either by repair, or in the company’s Please contact Trek’s Sales Department for the most up-to-
sole discretion, by replacement, any defect of material or date information before placing an order.
workmanship which develops within one year from date of
original purchase by the customer (user), provided that
investigation and factory inspection by the company Custom Solutions & OEM Applications
discloses that such defect developed under normal and
proper use. Trek can provide custom solutions for applications needing
more than an “off-the-shelf” product. Trek utilizes its decades
Calibration & Repair of experience and technical expertise to design, develop and
manufacture custom products which address the specific
TREK, INC. provides calibration and repair services for all Trek needs of an OEM application. Please contact Trek’s Sales
products. We have Authorized Service Organizations located Department about custom design services
around the world. Please contact Trek’s Customer Service
Department for assistance or go to www.trekinc.com to locate
a service facility. Demonstration Units

Trek has a variety of demonstration instruments available to


Rental Service introduce products to customers interested in verifying
operation for specific applications. To learn more about demo
Trek’s rental program provides cost-effective access to equipment please contact Trek’s Sales Department.
equipment for short-term projects or emergencies. For more
information, please contact Trek’s Sales Department.

For Assistance
Sales Department: TREK-CA@aei.com
Customer Service Department: TREK-CA@aei.com

In early 2018 Advanced Energy Industries, Inc. acquired Trek. Later in 2018, AE acquired
Monroe Electronics’ Electrostatic & ESD product line and relocated production and sales
to AE's Trek facilities in Lockport, NY.
www.trekinc.com www.trekinc.com/monroe/ www.advancedenergy.com

TREK, INC. TREK JAPAN KK


190 Walnut Street Kudankita 325 Building 7F
Lockport, New York 14094 USA 3-2-5 Kudankita, Chiyoda-ku
Toll Free: 1 800 FOR-TREK (1 800 367-8735) Tokyo, 102-0073, Japan
Tel: 1-716-438-7555 Tel: 81-3-6261-4680
Fax: 1-716-201-1804 Fax: 81-3-6261-4681
www.trekinc.com www.trekj.com
TREK-CA@aei.com sales@trekj.com

ISO 9001:2008

Trek products generate high voltage. Please read the instruction manual and notes carefully before using the instruments.

www.trekinc.com Dig2019June17

You might also like