Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Rack Modulador 9825 S.A

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

Analog Headend

Continuum Headend System


Model 9811 and 9814 Controllers
Model 9801 and 9802 Rear Interface Modules

Introduction
The Continuum Headend System product family provides
users with a vertically-oriented, compact, full featured
ensemble of headend functions. The Model 9811 and 9814
Controllers manage all activities between application modules
in addition to supporting external monitoring and control.

Description
All Continuum configurations require one controller and its
corresponding rear interface module per chassis. The Model
9811 and 9814 Controller Modules support all chassis level
functions required by any combination of application modules.
A controller and its Model 9801 or 9802 Rear Interface
Module (RIM) provide access to vital system connections
such as AC or DC power input, all back-up connections,
Transmission Network Control System (TNCS) connections,
and alarm interfacing. The controller also directs setup and
T22621
control of all application modules.

Model 9811/9814 Controller Modules are required to take advantage of the additional features and capabilities of
the Continuum Series 9825 Modulators. The Model 9811/9814 controllers are fully compatible with all versions of
Continuum Application Modules and can be used in place of Model 9810/9813 Controller Modules if required.

Note: Existing Model 9810/9813 Controller Modules need not be upgraded to Model 9811/9814 Controllers unless
Continuum Series 9825 Modulator Modules are present in that respective chassis. However, Model 9810/9813
Controllers can be upgraded to Model 9811/9814 Controller compatibility if necessary. Contact Scientific-Atlanta
factory service for details.

Features
Controller:
• Model 9811 Controller supports AC and DC powering
• Model 9814 Controller supports dual DC (-48 V DC) powering
• Expanded memory for new Model 9825M and 9825S Modulators
• Supports all Continuum Headend System application modules
• Microprocessor control and configuration
• Front panel remote terminal access (RS-232)
• 57.15 mm x 25.40 mm (2.25 in. x 1 in.) LCD display for all configuration and control functions
• Supports application module automatic back-up
• Plug & Play capability
• Universal AC powering with DC back-up input or dual DC powering
• Power factor corrected AC power supply
• Mechanically improved connector system

Rear Interface Module


• Interface for universal AC powering with DC back-up input or dual DC powering
• Back-up bus access supports external back-up control and large back-up groups (more than eight application
modules) with TNCS
• Provides SMC access to all application modules in the chassis (RS-485 and TTL)
Model 9811 / 9814 Controllers & Model 9801 / 9802 RIMs
Technical Details
Automatic Back-up
The controller initiates and maintains command over back-up signal routing in the event of an application module
malfunction. Continuous communication between the controller module and its application modules maintains up-
to-the-second system status. Extensive internal diagnostics within application modules, in coordination with
controller communication, speeds signal re-routing to a designated back-up module.

Dual Powering Options


Available powering options include AC powering with DC back-up (Model 9811), and DC powering with DC back-up
(Model 9814). For international applications, AC powering is universal (90 V AC to 264 V AC, 47 Hz to 63 Hz). DC
input range is -42 V DC to -60 V DC SELV. Both controllers support full chassis powering of any mix of application
modules.

Alarm Outputs
"Dry" contact closures are provided on the rear interface module for alarm connection. Users can select either
Normally Open (NO) or Normally Closed (NC) contact types for alarm outputs.

SMC (Status Monitoring and Control)


The SMC bus allows complete remote control operation of all application module functions and chassis level
functions managed by the controller module. Interface is via two RJ-14 style jacks on the controller that are
designed for loop-through cabling. This feature allows daisy-chaining of multiple SMC equipped units.

Local Control Port


The controller provides front panel access for local control of all functions. The local control port is equivalent to,
but electrically isolated from, the SMC interface. SMC activity has priority and is not affected by use of the local
control port.

Back-up Bus Access


This feature allows an external module outside the Continuum Headend System chassis to back-up a faulty
application module inside the chassis. This feature is useful when back-up groups larger than eight application
modules are desired. Back-up busses are available for audio (L, R, SAP, subcarrier) and baseband video.

Model 9825M and 9825S Modulators Memory Expansion


The new Continuum Modulators (Models 9825M and 9825S) contain added feature sets that require additional
memory in the controller module for proper operation. The Model 9811 and 9814 Controller Modules contain this
necessary memory expansion. Models 9810 and 9813 Controller Modules may be upgraded to Model 9811/9814
Controller capability.

Signal Flow Diagram

2
Model 9811 / 9814 Controllers & Model 9801 / 9802 RIMs
Specifications

Description Specification
AC Input Model 9811 (only)
90 V AC to 264 V AC, 50 Hz to 60 Hz, 375 W (max)
Power factor correction Model 9811 (only)
≥0.99 at 320 W load
Powering Mode # of Application Max. Controller Max. App. Module
Modules Power Dissipation Power Dissipation

AC Input 8 60 W 320 W

DC Input 0-8 10 W 320 W*


*Application module
powered directly
from external –48
V DC source
DC Input Model 9811 backup power (with Model 9801 RIM)
Model 9814 primary power (with Model 9802 RIM)
-42 V DC to -60 V DC SELV
Controller Interface
SMC Interface on rear interface module RS-422 or TTL
RS-485 compatible
9600 baud max
Local Control Port on Application Module RS-232, 9600 baud
Alarms-Terminal Strip Connectors
Normally Open Contact
Normally Closed Contact 1A DC max, 60 V SELV open circuit max. for all contacts
Common Contact

Ref Input 6.000 MHz ±60 Hz @ 1 V p-p ±10 dB, 75Ω

Ref Output 6.000 MHz ±60 Hz @ 1 V p-p minimum, 75Ω


Operating temperature 0°C to 50°C (32°F to 122°F)
Shipping weight Controller: 10 lbs (4.5 kg)
RIM: 3 lbs (1.4 kg)

Ordering Information
Description Part Number
Model 9811 AC & DC Controller Module 741160
Model 9814 DC & DC Controller Module 748030
Model 9811/9814 Memory Upgrade service for Model 9810/9813 Controller 748606
(contact S-A factory service)
Note: A controller rear interface module must be present in the chassis for the controller module to be operational.

3
Model 9811 / 9814 Controllers & Model 9801 / 9802 RIMs
Specifications

Connector Type
SMC Loop Two RJ-14 telephone connectors (loop through)
Video Backup BNC style connector 75Ω, 1 V p-p, DC - 8 MHz
Subcarrier Backup BNC style connector; 4.5 MHz audio subcarrier
75Ω, 1 V p-p, 4 MHz - 8 MHz
IF Backup (future feature) F style connector
Reference Input F style connector
Reference Output F style connector
R+, R- Terminal block, 2 terminals 600Ω, 0 dBm, 20 Hz - 20 kHz
GND Terminal block, 3 terminals
L/MONO +, L/MONO - Terminal block, 2 terminals 600Ω, 0 dBm, 20 Hz - 20 kHz
SAP+, SAP- Terminal block, 2 terminals 600Ω, 0 dBm, 20 Hz - 20 kHz
ALM (normally closed), ALM (normally open), COMMON Terminal block, 3 terminals

T22623
Ordering Information

Description Part Number


Model 9801 AC & DC Controller Rear Interface Module 546020
Model 9802 DC & DC Controller Rear Interface Module 546280
Note: A controller rear interface module must be present in the chassis for the controller module to be operational.

Scientific-Atlanta, the Scientific-Atlanta logo, and Continuum are registered trademarks of Scientific-Atlanta, Inc.
Specifications and product availability are subject to change without notice.
 2001 Scientific-Atlanta, Inc. All rights reserved.

Scientific-Atlanta, Inc.
1-800-722-2009 or 770-236-5400
www.scientificatlanta.com Part Number 750986 Rev A
November 2001

You might also like