where:
b = base width of the beam
d = effective depth
h = depth of the beam = d + (90 to 100)
Mu = moment due to load carried by the beam
Wu = factored load
DL = dead load
LL = live load
LOAD DISTRIBUTION
For short span:
WD∗Ls
WS = 3
𝑓𝑦
Ru = ϕρfy (1 − 0.59ρ )
𝑓𝑐′
𝑓𝑐′ 600
𝜌b = 0.85 𝑓𝑦 β1 (600+𝑓𝑦)
3 𝑓𝑐′
𝜌max = 7 0.85β1 𝑓𝑦
3 𝑓𝑐′
𝜌0.005 = 8 0.85β1 𝑓𝑦
1.4 √𝑓𝑐′
𝜌min = ;
𝑓𝑦 4𝑓𝑦
For 𝜌b:
21 600
𝜌b = 0.85(275)(0.85) (600+275) = 0.0378
1.4 √21
𝜌min = 275 = 0.0005 ; = 0.0004 The larger one controls
4(275)
∴ 𝜌min = 0.0005
𝜌b > 𝜌max and 𝜌min.
Say: 𝜌 = 70% (𝜌max)
𝜌 = 0.70(0.0236) = 0.0165
For 𝜌0.0005:
3 21
𝜌0.005 = 8 0.85(0.85) 275 = 0.0207
Since (𝜌 = 0.0165) < (𝜌0.005 = 0.0207) this means that the strain εt is larger than 0.005
∴ ϕ = 0.90
For Ru:
275
Ru = 0.90(0.0165)(275) (1 − 0.59(0.0165)( 21 ))
Ru = 3.56
B.1) For Roof Beam Dimensions
LONGITUDINAL BEAM
𝐿𝑠 2
DL∗Ls 3−( )
𝐿𝑙
WDL = 3
x 2
3.8 2 2.50 2
2.55∗3.8 3−( ) 2.55∗2.50 3−( )
WDL = [ 3
x 4.5
2
] +[ 3
x 2
4.5
] = 6.55 KN/m
1 1
Mu = 12 WuL2 = 12 (15.67) (4.5)2
Mu = 26.44 KN.m
TRANSVERSE BEAM
DL∗Ls 2.55∗3.80 2.55∗3.80
WDL = =[ ] +[ ] = 6.46 KN/m
3 3 3
𝑀𝑢
Effective depth, d = √𝑅𝑢∗𝑏 where: Ru = 3.56 from previous
computation
Check:
(Actual wt. of beam = 1.767 KN/m) < (Assumed wt. of beam = 4 KN/m), SAFE!
B.2) First Floor Beam
LONGITUDINAL BEAM
𝐿𝑠 2
DL∗Ls 3−( )
𝐿𝑙
WDL = 3
x 2
3.8 2 2.50 2
5.13∗3.8 3−( ) 5.13∗2.50 3−( )
WDL = [ 3
x 4.5
2
] +[ 3
x 2
4.5
] = 13.18 KN/m
3.8 2 2.50 2
1.9∗3.8 3−( ) 1.9∗2.50 3−( )
WLL = [ 3
x 4.5
2
] +[ 3
x 4.5
2
] = 4.88 KN/m
1 1
Mu = 12 WuL2 = 12 (36.52) (4.5)2
Mu = 61.63 KN.m
TRANSVERSE BEAM
DL∗Ls 5.13∗3.80 5.13∗3.80
WDL = =[ ] +[ ] = 13 KN/m
3 3 3
1 1
Mu = 12 WuL2 = 12 (36.2) (3.80)2
Mu = 43.56 KN.m
𝑀𝑢
Effective depth, d = √𝑅𝑢∗𝑏 where: Ru = 3.56 from previous computation
Check:
(Actual wt. of beam = 2.36 KN/m) < (Assumed wt. of beam = 4 KN/m), SAFE!
SUMMARY:
BEAM DIMENSIONS
Transverse Longitudinal
Level
b, mm d, mm b, mm d, mm
DEAD LOADS
Wt. of slab = 23.56 x 16.98 x 0.13 = 52.01
Roofing materials = 1.20 x 16.98 = 20.38
Ceiling materials = 0.20 x 16.98 = 3.40
Construction load = 1.10 x 16.98 = 18.68
Transverse beam = (0.25 x 0.30) x (23.56 x 3.815) = 6.74
Longitudinal beam = (0.25 x 0.30) x (23.56 x 4.45) = 7.86
LIVE LOADS
Roof live load = 1.90 x 16.98 = 32.26 KN
Ag = 25858.75 mm2
DEAD LOADS
Wt. of slab = 23.56 x 16.98 x 0.13 = 52
Ceiling materials = 0.20 x 16.98 = 3.40
Construction load = 1.10 x 16.98 = 18.68
Floor finish = 0.77 x 16.98 = 13.07
Interior Partition = (2.25 x 3)(16.98) = 114.615
Transverse beam = (0.25 x 0.40) x (23.56 x 3.815) = 10.48
Longitudinal beam = (0.25 x 0.40) x (23.56 x 4.45) = 8.99
Column = (0.30 x 0.30)(3)(23.56) = 6.36
LIVE LOADS
Roof live load = 1.90 x 16.98 = 32.26 KN
1.8𝑃𝑢
Ag = where: 𝜌𝑔 = 0.02
𝛼𝜙[0.85𝑓𝑐 ′ (1− 𝜌𝑔)+ 𝜌𝑔𝑓𝑦]
𝜙 = 0.65
1.8(324.74∗1000)
Ag = 0.85∗0.65[0.85∗21(1− 0.02)+ 0.02∗275] 𝛼 = 0.85
Ag = 46014.40 mm2
fc’ = 21 MPa
Fy = 275 MPa
RISE – 200mm
TREADS – 300mm
SOL’N
A.) WEIGHT OF SLAB = (23.56) (0.130) (√(200)2 + (300)2 )/1000 = 1.10 KN/m²
WEIGHT OF STEPS = (23.56) (0.30) (0.20) = 1.41 KN/m²
STAIR FINISH = 1KN (GIVEN)
LIVE LOAD = 5KN (GIVEN)
FACTORED LOAD
FACTORED LOAD
Let: Mu = øMn
W = 0.0503
𝑤 𝑓𝑐′ 0.0503 (21)
P= = = 0.00384
𝑓𝑦 275
MAIN BARS
As = P b d
As = 530.40 mm²
TEMP. BARS
As = 0.002bh
As = 260 mm²
SUMMARY
LOADINGS:
ROOFING MATERIAL (Asphalt Roof Shingles)= 0.1 KPa on roof surface
CEILING MATERIALS= 0.20 KPa on horizontal surface
Roof Live Load = 1KPa (Table 205-3)
WIND Velocity= 290 km/hr
BAYLENGTH= 4 m
TOP CHORD PANEL LENGTH (TCPL) = 1/3(2.02+42)1/2 = 1.50 m
BOTTOM CHORD PANEL LENGTH (BCPL) = 0.90 m
LOAD COMPUTATION:
Let :
W1 = Weight of Roofing Materials + Weight of Purlins
W2 = Weight of Ceiling Materials + Weight of Truss + Roof Live Load
W3 = Wind Load
Where:
W1 = (Roofing material) (Bay Length) (TCPL) + (Weight of Purlins) (Bay Length)
W1= (0.1) (4) (1.5) + (Weight of Purlins) (4) = 0.6 KN/PANEL+ Weight of Purlins (3.5)
W2 = (Ceiling material) (Bay Length) (BCPL) + (w) (Bay Length) (BCPL) + (RL) (Bay Length)
(BCPL )
But w = 0.019+0.0063L
= 0.019+0.0063(4.5)
= 0.05KPa
RL = 1KPa
W2= (0.20) (4) (0.9) + (0.05) (4) (0.9) + (1) (4) (0.9)
W2 = 4.5 KN/Panel
q = 0.613(0.724)(1)(0.85)(80.562)(1.15) = 2.815KPa
P Windward = 2.815((0.85)(0.054+0.18)) = 0.56 Kpa
P Leeward = 2.815((0.85)(-0.6-0.18)) = -1.87 KPa
ϴ = 23.96
2𝑆𝑖𝑛𝛳
Pn = 𝑃𝑣
1 + 𝑆𝑖𝑛2 𝛳
2𝑆𝑖𝑛(23.96)
Pn = 0.56
1 + 𝑆𝑖𝑛(23.96)2
Pn = 0.39 Kpa
W3 Windward = (0.39) (4) (1.5) = 2.34 KN/Panel
2𝑆𝑖𝑛𝛳
Pn = 𝑃𝑣
1 + 𝑆𝑖𝑛2 𝛳
2𝑆𝑖𝑛(23.96)
Pn = −1.87
1 + 𝑆𝑖𝑛(23.96)2
Pn = -1.30 Kpa
W3 Leeward = (-1.22) (4) (1.5) = -7.32 KN/Panel
Design of Purlins:
Solution:
WD = (1.5) (0.1) = 0.15 KN/m
WLr = (1.0) (1) = 1.0 KN/m
Wwindward = (1.5) (0.56) = 0.84 KN/m
WLeeward = (1.5) (1.87) = 2.81 KN/m
4.5 42
MDx = 0.15 (4.92) ( 8 ) = 0.27 KN.m
4.5 42
MLrx = 1 (4.92) ( 8 ) = 1.83 KN.m
42
Mwindward x = 0.84 ( 8 ) = 1.68 KN.m
42
MLeeward x = 2.81 ( 8 ) = 5.62 KN.m
2 42
MDy = 0.15 ( ) ( ) = 0.12 KN.m
4.92 8
2 42
MLry = 1 ( ) ( ) = 0.81 KN.m
4.92 8
LRFD Interaction Equation for Loads not applied thru Shear Center
𝑀𝑢𝑋 𝑀𝑢𝑌
+ Ø𝑏 𝑀𝑛𝑌 <1
Ø𝑏 𝑀𝑛𝑋
2
Where: Ø𝑏 = 0.9
𝑀𝑛𝑌 = FY ZY
𝑀𝑛𝑋 = FY ZX
Additional Weight due to Self-Weight
4.5 42
MDx = 1.2 Wsw (4.92) ( 8 ) = 2.20 Wsw
2 42
MDy = 1.2 Wsw (4.92) ( 8 ) = 0.98 Wsw
0.63 < 1 ok
Use W 100 X 19.3 for Purlins
Thus;
W1= 0.6 KN/PANEL+ Weight of Purlins (4)
W1= (0.6) + (0.189) (4) = 1.36 KN/PANEL
Computation for Reactions and Member Stresses
For Windward Direction
Rav = 19.02 Kn
Rah = 14.84 Kn
Rb = 22.96 Kn
Try:
L51 X 51 X 9.5 (AG = 879 mm2, r= 9.95)
AG = 879 mm2 > 216.61 mm2 OK!
AG = 879 mm2 > 198.56 mm2 OK!
𝐿
Min. r = 300
1500
= 300
FOR WELDING:
P=T= 41.59 KN
Use E60
ASD:
T = 0.3FexxAw
0.101325
Fexx = 60,000( )
14.7
= 413.57 MPa
41.59 = 0.3(413.57)Aw
33.61(1000)
Aw = = 335.21 mm
0.3(413.57)
LRFD:
Pu = Ø(0.6)(Fexx)(Aw)
41.59=(0.75)(0.6)(413.57)(Aw)
41.59(1000)
Aw =(0.75)(0.6)(413.57) = 223.47 mm
Use Aw = 335.21 mm
Aw = 0.707wL
335.21 = 0.707wL
335.21
L = 0.707(4.0)
L = 118.53 mm
ADOPT:
Weld size, w = 4.0 mm
Length of weld, L =120 mm