7 Power Cable EWLV1 - (CU/XLPE/GSWA/PVC), Flame Retardant
7 Power Cable EWLV1 - (CU/XLPE/GSWA/PVC), Flame Retardant
7 Power Cable EWLV1 - (CU/XLPE/GSWA/PVC), Flame Retardant
7
EWLV1 - (CU/XLPE/GSWA/PVC), Flame Retardant
8 Earthing Cable
9 Earthing Cable
11 Substation Building
B CABLE PULLING
Power Cable
1
EWLV1 - (CU/XLPE/GSWA/PVC), Flame Retardant
Power Cable
2
EWLV1 - (CU/XLPE/GSWA/PVC), Flame Retardant
Power Cable
3
EWLV1 - (CU/XLPE/GSWA/PVC), Flame Retardant
Power Cable
4
EWLV1 - (CU/XLPE/GSWA/PVC), Flame Retardant
Power Cable
5
EWLV1 - (CU/XLPE/GSWA/PVC), Flame Retardant
Power Cable
6
EWLV1 - (CU/XLPE/GSWA/PVC), Flame Retardant
Power Cable
7
EWLV1 - (CU/XLPE/GSWA/PVC), Flame Retardant
Power Cable
8
EWLV1 - (CU/XLPE/GSWA/PVC), Flame Retardant
9 Earthing Cable
- NYA - 1C - 95mm2
- Insulation grade : 450/750V
- Conductor : class 2, multi stranded annealed high conductivity copper, circular cross section
- Outer sheath : extruded PVC, green/yellow colored, flame retardant as per IEC 60332-1
- NYA - 1C - 150mm2
- Insulation grade : 450/750V
- Conductor : class 2, multi stranded annealed high conductivity copper, circular cross section
- Outer sheath : extruded PVC, green/yellow colored, flame retardant as per IEC 60332-1
- 4C - 240mm2
- Insulation Grade : 0.6/1kV
- Conductor : Multi-stranded, circular or shaped cross section annealed copper, Class 2 in accordance with IEC
60228
- Insulation : Cross linked polyethylene (XLPE) rated for 90deg.C
- Conductor Lay : cores laid up with non-hygroscopic fillers and binder tape (polyester tape) for above 5 cores
- Bedding : Extruded PVC
- Inner Sheath : Extruded PVC
- Armour : Galvanized steel wire armour
- Outer sheath : Extruded PVC, Black Colored, Flame retardant as per IEC 60332-3-22 category-A, anti vermin &
termites, UV protective
- 4C - 120mm2
- Insulation Grade : 0.6/1kV
- Conductor : Multi-stranded, circular or shaped cross section annealed copper, Class 2 in accordance with IEC
60228
- Insulation : Cross linked polyethylene (XLPE) rated for 90deg.C
- Conductor Lay : cores laid up with non-hygroscopic fillers and binder tape (polyester tape) for above 5 cores
- Bedding : Extruded PVC
- Inner Sheath : Extruded PVC
- Armour : Galvanized steel wire armour
- Outer sheath : Extruded PVC, Black Colored, Flame retardant as per IEC 60332-3-22 category-A, anti vermin &
termites, UV protective
- 4C - 95mm2
- Insulation Grade : 0.6/1kV
- Conductor : Multi-stranded, circular or shaped cross section annealed copper, Class 2 in accordance with IEC
60228
- Insulation : Cross linked polyethylene (XLPE) rated for 90deg.C
- Conductor Lay : cores laid up with non-hygroscopic fillers and binder tape (polyester tape) for above 5 cores
- Bedding : Extruded PVC
- Inner Sheath : Extruded PVC
- Armour : Galvanized steel wire armour
- Outer sheath : Extruded PVC, Black Colored, Flame retardant as per IEC 60332-3-22 category-A, anti vermin &
termites, UV protective
- 4C - 70mm2
- Insulation Grade : 0.6/1kV
- Conductor : Multi-stranded, circular or shaped cross section annealed copper, Class 2 in accordance with IEC
60228
- Insulation : Cross linked polyethylene (XLPE) rated for 90deg.C
- Conductor Lay : cores laid up with non-hygroscopic fillers and binder tape (polyester tape) for above 5 cores
- Bedding : Extruded PVC
- Inner Sheath : Extruded PVC
- Armour : Galvanized steel wire armour
- Outer sheath : Extruded PVC, Black Colored, Flame retardant as per IEC 60332-3-22 category-A, anti vermin &
termites, UV protective
- 4C - 35mm2
- Insulation Grade : 0.6/1kV
- Conductor : Multi-stranded, circular or shaped cross section annealed copper, Class 2 in accordance with IEC
60228
- Insulation : Cross linked polyethylene (XLPE) rated for 90deg.C
- Conductor Lay : cores laid up with non-hygroscopic fillers and binder tape (polyester tape) for above 5 cores
- Bedding : Extruded PVC
- Inner Sheath : Extruded PVC
- Armour : Galvanized steel wire armour
- Outer sheath : Extruded PVC, Black Colored, Flame retardant as per IEC 60332-3-22 category-A, anti vermin &
termites, UV protective
- 4C - 25mm2
- Insulation Grade : 0.6/1kV
- Conductor : Multi-stranded, circular or shaped cross section annealed copper, Class 2 in accordance with IEC
60228
- Insulation : Cross linked polyethylene (XLPE) rated for 90deg.C
- Conductor Lay : cores laid up with non-hygroscopic fillers and binder tape (polyester tape) for above 5 cores
- Bedding : Extruded PVC
- Inner Sheath : Extruded PVC
- Armour : Galvanized steel wire armour
- Outer sheath : Extruded PVC, Black Colored, Flame retardant as per IEC 60332-3-22 category-A, anti vermin &
termites, UV protective
- 4C - 10mm2
- Insulation Grade : 0.6/1kV
- Conductor : Multi-stranded, circular or shaped cross section annealed copper, Class 2 in accordance with IEC
60228
- Insulation : Cross linked polyethylene (XLPE) rated for 90deg.C
- Conductor Lay : cores laid up with non-hygroscopic fillers and binder tape (polyester tape) for above 5 cores
- Bedding : Extruded PVC
- Inner Sheath : Extruded PVC
- Armour : Galvanized steel wire armour
- Outer sheath : Extruded PVC, Black Colored, Flame retardant as per IEC 60332-3-22 category-A, anti vermin &
termites, UV protective
- 4C - 6mm2
- Insulation Grade : 0.6/1kV
- Conductor : Multi-stranded, circular or shaped cross section annealed copper, Class 2 in accordance with IEC
60228
- Insulation : Cross linked polyethylene (XLPE) rated for 90deg.C
- Conductor Lay : cores laid up with non-hygroscopic fillers and binder tape (polyester tape) for above 5 cores
- Bedding : Extruded PVC
- Inner Sheath : Extruded PVC
- Armour : Galvanized steel wire armour
- Outer sheath : Extruded PVC, Black Colored, Flame retardant as per IEC 60332-3-22 category-A, anti vermin &
termites, UV protective
- NYA - 1C - 25mm2
- Insulation grade : 450/750V
- Conductor : class 2, multi stranded annealed high conductivity copper, circular cross section
- Outer sheath : extruded PVC, green/yellow colored, flame retardant as per IEC 60332-1
M 50
M 50
lot 1
lot 1
M 2,160
M 650
M 130
M 350
M 730
M 550
M 180
M 1,300
M 200
lot 1