EQ10 Rev 2

Download as pdf or txt
Download as pdf or txt
You are on page 1of 11

Type

Conductor

Project Specification
CG-61A-06-7320-260219
Flame retardant according to IEC
60332-3-22
Stranded tinned copper wire
according to IEC 60228 class 2

French Standard (NF M 87-202)

NEK 606

BS5308

NF M 87-202 EIFA

RFOU (i) Instrumentation Cable,


250V, mud resistant

Part 1 Type 2 IAM CAM SWA

Solid or Stranded copper


conductor

0.5sqmm & 0.75sqmm class 5


Flexible copper,
1.0sqmm class 1 solid copper,
1.5sqmm class 2 stranded
copper
PE (Polyethylene)

Tinned Stranded Annealed


Copper Conductor to IEC60228
Class 2 (Flexible Class 5
conductors available upon
request)

Insulation
Twinning

Lay-up
Individual screen

Overall screen

XLPE, low smoke, low halogen


(<10%).
Each pair/triad/quad shall be
wrapped with polyester tape 0.023
mm thick, helically wound with 25 %
overlap
The pairs shall be laid up to form a
cable with a minimum of cross talk
Each pair/triad/quad shall be
screened with aluminium backed
Mylar tape helically applied with 25
% overlap. Aluminium on the inside
shall be in continuous contact with a
tinned stranded copper drain wire of
the same diameter as the conductor.
Thickness of screen shall be 0.018
mm aluminium on 0.023 mm Mylar
tape. Each screen shall be insulated
from the remaining cable
components by the application of
suitable tapes numbered in
accordance with the pair/triad/quad
numbering system
The pair/triad/quad shall be
screened with aluminium backed
Mylar tape helically wrapped with a
25 % overlap. Aluminium on the

PVC

EPR Complying with IEC60092351

Polyster tape

70 mm maximum pair length


Aluminium/polyester tape

Two / Three insulated cores


shall be twisted together to
form a pair/triple
-

Aluminium or Copper Mylar


Tape Screen in contact with
Tinned Copper drain wire

Aluminium/polyester tape

Pairs/Triples/Quads

None

IAM (Individual aluminium


mylar)

CAM (Collective aluminium


mylar)

Inner sheath
Wrapping below inner sheath
Armour

Overall outer sheath

Outer sheath colour


Conductor Colours
Standards

inside shall be in continuous contact


with a tinned stranded copper drain
wire of the same diameter as the
conductor. Thickness of screen shall
be 0.018 mm aluminium on 0.023
mm Mylar tape.
PVC, low smoke, low halogen

PVC

PE (Polyethylene)

Flame Retardant Halogen Free


Compound, PETP-tape

The screened cable shall be wrapped


with Polyester tape helically wound
Galvanised Steel Wire Braids
coverage (density and thickness in
accordance with IEC 60092-376).
PVC, low smoke, low halogen
(<10%), flame retardant type in
accordance with IEC 60332-3-22.
The outer-sheath shall be resistant
to water, UV, and aliphatic
hydrocarbons or aromatic
hydrocarbons (when required)

Polyester tape

non-intrinsically safe Light Grey


intrinsically safe Dark Blue
Pairs Red/White

Light-blue

Black/Blue

Black/Blue

Pairs Red/White
NF M 87-202
UTE C 32-014
NF C 32-020
IEC 60332-1
IEC 60332-3-24

Pairs: Black & Blue


NEK 606 / IEC 60092-3
IEC 60092-351
IEC 60332 part 3 (Category A)
IEC 60092-359
Stranded class 2 or tinned
annealed copper conductors to
IEC60228

BS5308 Colour Code


BS5308 Part 1 ,Insulated
cables, instrumentation, PE
BS6234: Specification for
polyethylene insulation and
sheath of electric cables
Flame Propagation Test to BS
EN 60332-1-2

Double Steel Tape

Tinned Copper Wire Braid to NVE

SWA (Single wire armour)

FEA-M 1238.5, PETP-tape

PVC (Flame retardant, sunlight,


mineral oil and hydrocarbon
resistant)

SHF2 dual Compound thermoset


rubber - IEC60092-359 Type SHF2,
Dual rated as being

PVC (Polyvinyl-Chloride)

Both halogen free and mud resistant


in accordance with NEK606, and
meets cold bend and
Impact test (-20C) cross sectional
area C22.2.

Instrumentation Cables
French Standard (NF M 87-202)

NF M 87-202 EIFA
Applications:
These NF M 87-202 EIFA instrumentation cables are used for safety extra-low use in petroleum and
petrochemical units particularly for the transmission of a.c. or d.c. analogue signals, They are well adapted
to underground use in industrial applications where hydrocarbons may be present and mechanical
protections are needed (refinery areas, chemical plant).

Construction:

PVC Inner Sheath


Aluminium/Polyester tape
Polyster tape
Polyster Tape
PVC Insulation
Copper Conductor
Aluminium/Polyester Tape
PVC Individual Sheath
Double Steel Tape
PVC Outer Sheath

Conductor:
Solid or Stranded copper conductor
Insulation:
PVC (70 mm maximum pair length)
Individual Binder Tape:
Polyster tape
Individual Screen:
Aluminium/polyester tape
Individual Sheath:
PVC
Overall Binder Tape :
Polyster tape
Collective Screen:
Aluminium/polyester tape

www.caledonian-cables.co.uk www.addison-cables.com

17

Instrumentation Cables
French Standard (NF M 87-202)
Inner Sheath: PVC
Amouring:
Double Steel Tape
Outer Sheath:
PVC (Flame retardant, sunlight, mineral oil and hydrocarbon resistant)
Outer Sheath Colour:
Light-blue
Core identification:
Colours

Natural

Red

Blue

1 pair

1 triple

1 quad

Natural cores printed with pair/triple number

Standards References:
NF M 87-202
UTE C 32-014
NF C 32-020
IEC 60332-1
IEC 60332-3-24

Characteristics:
Voltage Rationg: 300/500V
Operating Temperature: -40C/+90C
Installation Temperature: MAX+50C
Maximum Voltage: 250V
Voltage Test: 2000V
Maximum conductor d.c. Resistance:

18

Conductor Size

Ohm/km at +20C

1/0.80mm(0.50 sqmm)

37.50

7/0.40mm(0.88 sqmm)

21.40

www.caledonian-cables.co.uk www.addison-cables.com

Yellow

Instrumentation Cables
French Standard (NF M 87-202)
7/0.53mm(1.50 sqmm)

12.50

Capacitance between cond. (nf/km):


0.5 sqmm 145
0.88 sqmm 160
1.50 sqmm 180
Type/codification:
1 Serie

Number of pairs, triples or quads / 01 to 27

2 Serie

Lay up in pair(IP) ,triple (IT) , quads (IQ)

3 Serie

Core section 05 (0.5mm2) , 09 (0.88 mm2) or 15(1.5mm2)

4 Serie

Overall screen(EG) or individual screen + overall screen(EI)

5 Serie

Mechanical protection: without armour (SF), with armour (FA), with lead + armour(PF)

Dimensions and Weight:

NF M 87-202

Number of
beams
x cross
section

Cond.
mm2

03 IP 05 EIFA
07 IP 05 EIFA
12 IP 05 EIFA
19 IP 05 EIFA
27 IP 05 EIFA
03 IP 09 EIFA
07 IP 09 EIFA
12 IP 09 EIFA
19 IP 09 EIFA
27 IP 09 EIFA
03 IP 09 EIFA
07 IP 09 EIFA
12 IP 09 EIFA
19 IP 09 EIFA
27 IP 09 EIFA
01 IP 15 EIFA
07 IT 05 EIFA
12 IT 05 EIFA
12 IT 09 EIFA
01 IT 15 EIFA

3X2X0.50
7X2X0.50
12X2X0.50
19X2X0.50
27X2X0.50
3X2X0.88
7X2X0.88
12X2X0.88
19X2X0.88
27X2X0.88
3X2X0.88
7X2X0.88
12X2X0.88
19X2X0.88
27X2X0.88
1X2X1.50
7X3X0.50
12X3X0.50
12X3X0.88
1X3X1.50

0.50
0.50
0.50
0.50
0.50
0.88
0.88
0.88
0.88
0.88
0.88
0.88
0.88
0.88
0.88
1.50
0.50
0.50
0.88
1.50

Outer Diameter(mm)
Min.
14.20
18.60
23.30
28.10
32.80
18.50
22.90
29.00
34.80
40.60
16.70
22.40
28.10
34.10
39.80
10.20
20.30
25.40
25.00
10.50

Max.
16.20
21.40
26.70
32.30
37.60
20.40
25.30
32.00
38.40
44.80
19.20
25.70
32.30
39.10
45.70
11.70
23.30
28.00
28.70
12.00

Weight
(kg/km)
355
570
850
1210
1600
465
792
1205
1709
2275
270
800
1185
1720
2285
200
690
1005
1025
220

www.caledonian-cables.co.uk www.addison-cables.com

19

BS6883
RFOU(i) Pairs/Triples Armoured
Cables Individually Screened:

NEK606

Offshore Instrumentation Cables to NEK606 Specification

Applicable Standards
NEK 606 / IEC 60092-3
IEC 60092-351
IEC 60332 part 3 (Category A)
IEC 60092-359
Stranded class 2 or tinned annealed copper
conductors to IEC60228

IEEE

150/250V
Flame Retardant

This range of cables is designed for use in fixed


wiring on ships and offshore platforms and drilling rigs,
especially used where life may be endangered by
smoke and noxious fumes, and where sensitive
equipment may be damaged by acid forming gases.

IEC

Application

Conductor Identification
Single Pair: Black/ Light Blue
Triples: Black/ Light Blue/ Brown
Note: picture is for illustration purposes only

New harmonised core colours or project specified colours


can be supplied upon special request

Construction

Specifications

(1) Conductor:

Tinned Stranded Annealed Copper Conductor to IEC60228 Class 2 (Flexible Class 5 conductors available upon
request)

(2) Insulation:

(R) EPR Complying with IEC60092-351

(3) Individual Screen:

Aluminium or Copper Mylar Tape Screen in contact with Tinned Copper drain wire

(4) Bedding:

(F) - Flame Retardant Halogen Free Compound, PETP-tape

(5) Armour:

(O) - Tinned Copper Wire Braid to NVE FEA-M 1238.5, PETP-tape

(6) Outer Sheath:

(U) - SHF2 dual Compound thermoset rubber - IEC60092-359 Type SHF2, Dual rated as being
Both halogen free and mud resistant in accordance with NEK606, and meets cold bend and
Impact test (-20C) cross sectional area C22.2.

INTERKAB House
Aberdeen, AB11 5DY
Tel: 0044 (0)1224 595 640
Fax: 0044 (0)1224 594 416
Email: info@interkab.com

Datasheet Ref: OFS-NK-INS-IS-FR

www.interkab.com

150/250V
Flame Retardant

Offshore Instrumentation Cables to NEK606 Specification

RFOU(i) Pairs/Triples Armoured Cables - Table 1/2


Cable

1x2x0.75 2x2x0.75 4x2x0.75 8x2x0.75 12x2x0.75 16x2x0.75 24x2x0.75

1x2x1.5

2x2x1.5

4x2x1.5

8x2x1.5

12x2x1.5 16x2x1.5 24x2x1.5

Stranding mm

7/0.37

7/0.37

7/0.37

7/0.37

7/0.37

7/0.37

7/0.37

7/0.53

7/0.53

7/0.53

7/0.53

7/0.53

7/0.53

7/0.53

Insulation Thickness mm

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

Thickness of Inner Sheath mm

1.1

1.1

1.1

1.1

1.3

1.4

1.6

1.1

1.1

1.1

1.1

1.3

1.4

1.8

Diameter over Inner Sheath


(min/max) mm

7.2/8.8

10.5/12.5

12.5/14.5

17.5/19.5

20.0./23.0

22.5/25.5

28.0/31.0

8.2/9.8

12.5/14.5

14.5/16.5

19.5/22.5

23.5/26.5

26.5/29.5

32.5/36.5

Diameter of Armour/Braid mm

0.2

0.2

0.3

0.3

0.3

0.3

0.3

0.2

0.3

0.3

0.3

0.3

0.3

0.4

Thickness of Outer Sheath mm

1.1

1.2

1.3

1.5

1.6

1.7

1.9

1.1

1.3

1.4

1.6

1.8

1.9

2.2

Overall Diameter (min/max) mm

10.0/12.0

14.0/16.0

16.5/18.5

21.0/24.0

24.5/27.5

27.0/30.0

33.0/37.0

11.0/13.0

16.0/18.0

18.5/20.5

24.0/27.0

28.0/32.0

31.0/35.0

38.0/43.0

Gland Size

C2

C2

Weight kg/km

200

330

470

790

1080

1330

1920

240

450

620

1070

1530

1860

2760

Bend Radius - xOD

Conductor Temperature - C

85

85

85

85

85

85

85

85

85

85

85

85

85

85

Short Circuit Rating, 1second


250c - A

100

100

100

100

100

100

100

100

100

100

100

100

100

100

Inductance/ Resistance mH/km

0.75

0.75

0.75

0.75

0.75

0.75

0.75

0.68

0.68

0.68

0.68

0.68

0.68

0.68

Capacitance nF/KM

90

90

90

90

90

90

90

110

110

110

110

110

110

110

DC Resistance @ 20c Ohms/km

24.8

24.8

24.8

24.8

24.8

24.8

24.8

12.2

12.2

12.2

12.2

12.2

12.2

12.2

Sheath Colour

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/ Blue

Grey/ Blue

Grey/ Blue

Grey/Blue

Grey/Blue

RFOU(i) Pairs/Triples Armoured Cables - Table 2/2


1x3x1.5

2x3x1.5

4x3x1.5

8x3x1.5

Stranding mm

Cable

1x3x0.75 2x3x0.75 4x3x0.75 8x3x0.75 12x3x0.75 16x3x0.75 24x3x0.75


7/0.37

7/0.37

7/0.37

7/0.37

7/0.37

7/0.37

7/0.37

7/0.53

7/0.53

7/0.53

7/0.53

12x3x1.5 16x3x1.5 24x3x1.5


7/0.53

7/0.53

7/0.53

Insulation Thickness mm

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

Thickness of Inner Sheath mm

1.1

1.1

1.1

1.1

1.3

1.4

1.8

1.1

1.1

1.1

1.1

1.3

1.6

1.8

Diameter over Inner Sheath


(min/max) mm

7.7/9.3

12.0/14.0

14.0/16.0

18.5/21.5

23.0./26.0

25.0/29.0

31.5/35.5

8.7/10.3

14.0/16.0

16.5/18.5

21.5/24.5

27.0/30.0

30.0/34.0

37.5/41.5

Diameter of Armour/Braid mm

0.2

0.3

0.3

0.3

0.3

0.3

0.3

0.2

0.3

0.3

0.3

0.3

0.3

0.4

Thickness of Outer Sheath mm

1.1

1.3

1.4

1.6

1.7

1.8

1.1

1.4

1.5

1.7

1.9

2.3

Overall Diameter (min/max) mm

10.5/12.5

15.5/17.5

18.0/20.0

23.0/26.0

27.5/30.5

30.0/34.0

37.5/41.5

12.0/14.0

18.0/20.0

20.0/23.0

26.5/29.5

31.5/35.5

35.5/39.5

43.5/48.5

Gland Size

C2

C2

C2

Weight kg/km

210

420

560

950

1350

1630

2550

300

550

780

1390

1970

2570

3790

Bend Radius - xOD

Conductor Temperature - C

85

85

85

85

85

85

85

85

85

85

85

85

85

85

Short Circuit Rating, 1second


250c - A

100

100

100

100

100

100

100

100

100

100

100

100

100

100

Inductance/ Resistance mH/km

0.75

0.75

0.75

0.75

0.75

0.75

0.75

0.68

0.68

0.68

0.68

0.68

0.68

0.68

Capacitance nF/KM

90

90

90

90

90

90

90

110

110

110

110

110

110

110

DC Resistance @ 20c Ohms/km

24.8

24.8

24.8

24.8

24.8

24.8

24.8

12.2

12.2

12.2

12.2

12.2

12.2

12.2

Sheath Colour

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/Blue

Grey/ Blue

Grey/ Blue

Grey/ Blue

Grey/Blue

Grey/Blue

INTERKAB House
Aberdeen, AB11 5DY
Tel: 0044 (0)1224 595 640
Fax: 0044 (0)1224 594 416
Email: info@interkab.com

Datasheet Ref: OFS-NK-INS-IS-FR

www.interkab.com

BS5308 Cable Part 1 Type 2 IAM CAM SWA


Applications:

Conductors:

Insulation:
Core identification:
Screen:
Sheath/Jacket:
Colour:
Voltage:
Bedding:
Armour / Protection:
Bending Radius:
Temperature range:
Standards:

Note:

BS5308 part 1 type 2 armoured instrumentation cable suitable for use


underground. Indoor and outdoor installations, generally used within industrial process
plants and for data & voice transmission services. Also used for the interconnection of
electrical equipment and instruments, particularly in and around process plants, where
transducer generated signals are transmitted through marshalled circuits to panels,
controllers and associated devices
Part 1 cables are widely used throughout the petroleum industry.
Type 2 armoured cables are suitable for direct burial
0.5sqmm & 0.75sqmm class 5 Flexible copper,
1.0sqmm class 1 solid copper,
1.5sqmm class 2 stranded copper
PE (Polyethylene)
Please see colour code link in technical information
IAM (Individual aluminium mylar) & CAM (Collective aluminium mylar)
PVC (Polyvinyl-Chloride)
Black or Blue
300/500v
PE (Polyethylene)
SWA (Single wire armour)
6 x overall diameter
Operating -40 to +65C. Installation 0 to +50C
BS5308 Part 1 ,Insulated cables, instrumentation, PE
BS6234: Specification for polyethylene insulation and sheath of electric cables
Flame Propagation Test to BS EN 60332-1-2
If you are considering installing in high UV exposure and/or high/low ambient
temperatures i.e. desert/arctic conditions then special sheathing may be required

Electrical Characteristics
Conductor size
Mutual Capacitance:
a. Cables with only collective screens (except one pair
and two pair)- pf/fm
b. One pair and two pair cables collectively screened
and all cables with individually screened pairs. pf/fm
Conductor resistance: Max resistance: Max dc
resistance at 20C ohms/Km
L/R ratio (maximum value) microH/ohm

0.5mm
(16/.2)

0.75mm
(24/.2)

1.00mm (1/1.13)

1.5mm (7/0.53)

75

75

75

85

115

115

115

120

39.7

26.5

18.4

12.3

25

25

25

40

www.batt.co.uk
battindustrial.sales@batt.co.uk

BS5308 Part 1 Type 2 Collectively screened and armoured - pairs


Conductor
size (mm)
16/0.20
(0.5mm)

24/0.20
(0.75mm)
Generally
to BS5308

1/1.13
(1.00mm)

7/0.53
(1.5mm)

7/0.67
(2.5mm)

No of Pairs
BATT part no Black
BATT part no Blue
Under Armour
Over Armour
Overall Diameter
Weight Kg/KM
Gland CW /Size
Gland part no
BATT part no Black
BATT part no Blue
Under Armour
Over Armour
Overall Diameter
Weight Kg/KM
Gland CW/Size
Gland part no
BATT part no Black
BATT part no Blue
Under Armour
Over Armour
Overall Diameter
Weight Kg/KM
Gland CW /Size
Gland part no
BATT part no Black
BATT part no Blue
Under Armour
Over Armour
Overall Diameter
Weight Kg/KM
Gland CW/Size
Gland part no
BATT part no Black
BATT part no Blue
Under Armour
Over Armour
Overall Diameter
Weight Kg/KM
Gland CW /Size
Gland part no

1
85123
85001
7
8.8
11.4
210
20s
88591
85251
85250
7.3
9.1
11.7
240
20s
88591
85181
85226
7.4
9.2
11.8
230
20s
88591
85012
85011
8.3
10.1
12.9
310
20s
88591
85691
8.5
10.3
13.1
363
-

Nominal dimensions (mm), Weights and Gland sizes


2
5
10
15
85113
85120
85030
85227
85018
85029
7.9
13.1
17.2
19.8
9.7
14.9
19.7
23
12.3
17.9
22.9
26.4
260
470
810
1160
20s
20
25
32
88591
88592
88594
88594
85416
85418
85419
85619
85583
85620
85566
8.3
14.3
18.7
21.4
10.1
15.8
21.9
24.6
12.9
18.8
25.3
28.2
290
600
1080
1310
20s
25
25
32
88591
88593
88593
88594
85187
85031
85454
85267
85633
8.4
14.2
18.4
21.3
1.2
16.7
20.9
24.5
13
19.7
24.3
28.1
280
690
980
1370
20s
25
25
32
88591
88593
88593
88594
85243
85118
85494
85478
85688
85311
9.7
16.4
21.6
25.2
11.5
18.9
24.8
28.4
14.3
22.1
28.4
32.2
400
850
1600
1850
20s
25
32
32
88591
88593
88594
88594
-

www.batt.co.uk
battindustrial.sales@batt.co.uk

20
85307
85711
22.3
25.5
29.1
1370
32
88893
85501
85621
24.5
27.7
31.3
1560
32
88594
85645
24.4
27.6
31.2
1670
32
88594
85689
85690
28.5
31.7
25.7
2400
40
88593
-

30
26.9
30.1
33.9
1760
40
88919
85605
29.5
33.5
37.5
2290
40
88893
29.0
32.2
36.2
2160
40
88893
85769
34.3
38.3
42.5
3000
50s
88919
-

50
33.9
37.9
42.1
2730
50s
88919
37.4
41.4
45.8
3620
50
88439
37.3
41.4
45.7
3440
50
88439
43.6
48.6
53.4
5000
63s
88918
-

BS5308 Part 1 Type 2 Individual and Collective Screen Armoured Pairs


Conductor
size (mm)
16/0.20
(0.5mm)

24/0.20
(0.75mm)
Generally
to BS5308

1/1.13
(1.00mm)

7/0.53
(1.5mm)

No of Pairs
BATT part no Black
BATT part no Blue
Under Armour
Over Armour
Overall Diameter
Weight Kg/KM
Gland CW /Size
Gland part no
BATT part no Black
BATT part no Blue
Under Armour
Over Armour
Overall Diameter
Weight Kg/KM
Gland CW/Size
Gland part no
BATT part no Black
BATT part no Blue
Under Armour
Over Armour
Overall Diameter
Weight Kg/KM
Gland CW /Size
Gland part no
BATT part no Black
BATT part no Blue
Under Armour
Over Armour
Overall Diameter
Weight Kg/KM
Gland CW/Size
Gland part no

1
-

Nominal dimensions (mm), Weights and Gland sizes


2
5
10
15
85002
85111
85281
85061
85015
85027
85047
85060
12
15.2
21.1
23.2
13.7
17.7
24.3
26.4
16.7
20.9
27.9
30
450
750
1280
1440
20
25
25
32
88592
88593
88593
88594
85254
85257
85064
85253
85165
85104
12.8
16.3
22.7
26.4
14.6
18.8
25.9
29.6
17.6
22
29.5
33.4
500
950
1650
1800
20
25
32
32
88592
88593
88594
88594
85404
85324
85332
85107
86198
85326
12.8
16.2
22.6
26.2
14.6
18.7
25.8
29.4
17.6
21.9
29.4
33.2
520
950
1690
1800
20
25
32
32
88592
88593
88594
88594
85217
85152
85019
85033
85055
85063
14.7
18.8
26.5
30.8
17.2
22
29.7
34
204
25.4
33.5
38.8
750
1200
1900
2500
25
32
40
40
88593
88594
88893
88893

www.batt.co.uk
battindustrial.sales@batt.co.uk

20
85325
85070
27.3
30.5
34.3
1810
40
88893
85098
85304
29.8
33.8
37.8
2400
50s
88919
29.8
33.8
37.8
2500
50s
88919
85381
85079
34.4
38.4
42.6
3100
50s
88919

30
85087
32.3
36.3
40.5
2610
50s
88919
35.5
39.5
43.9
3100
50s
88919
35.4
39.4
43.8
3300
50
88439
85534
85089
41
46
5.8
4000
50
88439

50
85096
41.7
46.7
51.5
4180
63s
88918
45
50
55
4900
63s
88918
44.9
49.9
54.9
5300
63s
88918
52.2
57.2
62.6
6400
63
88895

BS5308 Part 1 Type 2 Collectively screed and armoured triples


Conductor
size (mm)
16/0.20
(0.5mm)

24/0.20
(0.75mm)
Generally
to BS5308

1/1.13
(1.00mm)

7/0.53
(1.5mm)

No of Pairs
BATT part no Black
BATT part no Blue
Overall Diameter
Under Armour
Over Armour
Weight Kg/KM
BATT part no Black
BATT part no Blue
Overall Diameter
Under Armour
Over Armour
Weight Kg/KM
BATT part no Black
BATT part no Blue
Overall Diameter
Under Armour
Over Armour
Weight Kg/KM
BATT part no Black
BATT part no Blue
Overall Diameter
Under Armour
Over Armour
Weight Kg/KM

1T
85163
85116
11.5
6.5
8.3
242
85252
11.5
6.7
8.5
260
11.7
6.9
8.7
270
85114
85139
12.9
8.1
10
320

Nominal dimensions (mm), Weights and Gland sizes


3T
4T
5T
8T
12T
17.1
18.1
19.5
23.7
26.9
11.5
12.4
13.5
17
20
14
15
16
20.2
23.2
530
590
650
1020
1260
85729
17.6
18.7
21.5
24.8
27.0
11.9
13.0
14.5
18
21
14.5
15.6
17.7
21.3
23.3
560
640
930
1150
1220
17.7
19
21.1
24.7
28.1
12.1
13.3
14.7
17.9
21.1
14.6
15.9
17.8
21.2
24.4
600
680
780
1200
1500
85622
20.0
22.1
24.3
28.2
33.3
14.1
15.5
17.5
21.2
25.3
16.7
18.8
20.8
24.5
29.4
740
970
1150
1500
2150

15T
29.3
22.4
25.6
1450
31
23.8
27.1
1650
30.7
23.5
26.8
1800
36.2
28.0
32.1
2500

20T
33.3
25.4
29.4
1950
32.5
25.2
28.5
2000
35.1
26.9
31
2400
40.5
32.1
36.2
3050

BS5308 Part 1 Type 2 Collectively screened and armoured - quads


Conductor
size (mm)
16/0.20
(0.5mm)

24/0.20
(0.75mm)
Generally
to BS5308

1/1.13
(1.00mm)

7/0.53
(1.5mm)

No of Pairs
BATT part no Black
BATT part no Blue
Overall Diameter
Under Armour
Over Armour
Weight Kg/KM
BATT part no Black
BATT part no Blue
Overall Diameter
Under Armour
Over Armour
Weight Kg/KM
BATT part no Black
BATT part no Blue
Overall Diameter
Under Armour
Over Armour
Weight Kg/KM
BATT part no Black
BATT part no Blue
Overall Diameter
Under Armour
Over Armour
Weight Kg/KM

Nominal dimensions (mm), Weights and Gland sizes


1Q
3Q
4Q
5Q
85113
85227
11.8
18.6
20.3
22.5
7.0
12.9
14.4
15.9
8.9
15.5
17.0
19.2
270
600
800
920
85416
85619
12.3
20
22.1
24.2
7.5
14.1
15.5
17.4
9.4
16.7
18.8
20.7
290
690
920
1050
85187
85267
12.2
20
22.1
24.2
7.5
14.1
15.5
17.4
9.4
16.7
18.8
20.7
300
715
960
1100
85243
85478
13.6
23.4
25
27.5
8.8
16.6
18.2
230.5
10.7
19.9
21.5
23.8
350
1020
1170
1360

8Q
25.8
19.0
22.3
1150
27.9
20.9
24.2
1350
27.9
20.9
24.2
1450
32
24.8
28.1
1800

www.batt.co.uk
battindustrial.sales@batt.co.uk

12Q
30.2
23.2
26.5
1500
33.4
25.4
29.5
2000
33.4
25.4
29.5
2100
38.5
30.1
34.2
2650

15Q
33.8
25.8
29.9
2000
36.6
28.2
32.4
2250
36.6
28.2
32.4
2400
42
33.4
37.5
3050

20Q
37.7
29.5
33.6
2350
41
32.4
36.5
2850
41
32.4
36.5
3000
48.1
38.3
43.4
4200