Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

E&H Radar Manual

Download as pdf or txt
Download as pdf or txt
You are on page 1of 84

TI01303F/00/EN/03.

17 Products Solutions Services


71375858

Technical Information
Micropilot FMR62
Free space radar

Level measurement in liquids

Application
• Continuous, non-contact level measurement of liquids,
pastes and sludges
• Integrated PEEK antenna or PTFE-plated, flush-mounted antenna
• Maximum measuring range: 80 m (262 ft)
• Temperature: –40 to +200 °C (–40 to +392 °F)
• Pressure: –1 to +25 bar (–14.5 to +362.6 psi)
• Accuracy: ± 1 mm (0.04 in)
• Linearity protocol (3-point, 5-point)

Your benefits
• Reliable measurement thanks to improved focusing and small beam angle,
particularly in vessels with many internal fittings
• Compact design enables installation in the case of small vessels and small process
connections
• Safety by design - ensures highest safety
• Easy, guided commissioning with intuitive user interface
• Maximum reliability thanks to multi-echo tracking
• HistoROM configuration memory makes for easier commissioning,
maintenance and diagnostics
• SIL2 as per IEC 61508, SIL3 for homogeneous or diverse redundancy
• Easy proof testing for SIL and WHG
• RFID TAG - easy identification of measuring points for improved data access
• Heartbeat Technology
Micropilot FMR62

Table of contents

Important document information . . . . . . . . . . . . . . . 4 Storage temperature . . . . . . . . . . . . . . . . . . . . . . . . . . 37


Safety symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Climate class . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Electrical symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Altitude according to IEC61010-1 Ed.3 . . . . . . . . . . . . . . 37
Symbols for certain types of information . . . . . . . . . . . . . . 4 Degree of protection . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Symbols in graphics . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Vibration resistance . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Symbols at the device . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Electromagnetic compatibility (EMC) . . . . . . . . . . . . . . . 38

Terms and abbreviations . . . . . . . . . . . . . . . . . . . . . 6 Process . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39


Process temperature, process pressure . . . . . . . . . . . . . . . 39
Dielectric constant . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Registered trademarks . . . . . . . . . . . . . . . . . . . . . . . 7

Mechanical construction . . . . . . . . . . . . . . . . . . . . 43
Function and system design . . . . . . . . . . . . . . . . . . . 8
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Measuring principle . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Materials: GT18 housing (stainless steel, corrosion-
Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 resistant) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
Measured variable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Materials: GT19 housing (plastic) . . . . . . . . . . . . . . . . . . 52
Measuring range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Materials: GT20 housing (die-cast aluminum, powder-
Operating frequency . . . . . . . . . . . . . . . . . . . . . . . . . . 13 coated) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
Transmission power . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Materials: antenna and process connection . . . . . . . . . . . 54
Materials: Weather protection cover . . . . . . . . . . . . . . . . 56
Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Output signal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Operability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
Signal on alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Operating concept . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
Linearization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Local operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
Galvanic isolation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Operation with remote display and operating module
Protocol-specific data . . . . . . . . . . . . . . . . . . . . . . . . . . 16 FHX50 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
Remote operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
SupplyCare inventory management software . . . . . . . . . . 60
Power supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Terminal assignment . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Device plug connectors . . . . . . . . . . . . . . . . . . . . . . . . . 21 Certificates and approvals . . . . . . . . . . . . . . . . . . . 63
Supply voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 CE mark . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Power consumption . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 RoHS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Current consumption . . . . . . . . . . . . . . . . . . . . . . . . . . 23 RCM-Tick marking . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Power supply failure . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Ex approval . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Potential equalization . . . . . . . . . . . . . . . . . . . . . . . . . 23 Dual seal according to ANSI/ISA 12.27.01 . . . . . . . . . . . . 63
Cable entries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Functional safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Cable specification . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 WHG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Overvoltage protection . . . . . . . . . . . . . . . . . . . . . . . . . 24 Hygienic compatibility . . . . . . . . . . . . . . . . . . . . . . . . . 63
NACE MR 0175 / ISO 15156 . . . . . . . . . . . . . . . . . . . . . 64
NACE MR 0103 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
Performance characteristics . . . . . . . . . . . . . . . . . . 26
Pressure equipment with allowable pressure
Reference operating conditions . . . . . . . . . . . . . . . . . . . 26
≤ 200 bar (2 900 psi) . . . . . . . . . . . . . . . . . . . . . . . . . . 64
Reference accuracy . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Marine approval . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
Measured value resolution . . . . . . . . . . . . . . . . . . . . . . 26
Radio standard EN 302729-1/2 . . . . . . . . . . . . . . . . . . . 64
Response time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Radio standard EN 302372-1/2 . . . . . . . . . . . . . . . . . . . 65
Influence of ambient temperature . . . . . . . . . . . . . . . . . 27
FCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
Influence of gas phase . . . . . . . . . . . . . . . . . . . . . . . . . 27
Industry Canada . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
CRN approval . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Test, certificate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
Installation conditions . . . . . . . . . . . . . . . . . . . . . . . . . 28 Hard-copy product documentation . . . . . . . . . . . . . . . . . 67
Installation: integrated antenna . . . . . . . . . . . . . . . . . . . 32 Other standards and guidelines . . . . . . . . . . . . . . . . . . . 68
Installation: flush mount antenna . . . . . . . . . . . . . . . . . . 33
Container with heat insulation . . . . . . . . . . . . . . . . . . . . 35
Ordering information . . . . . . . . . . . . . . . . . . . . . . . 69
Ordering information . . . . . . . . . . . . . . . . . . . . . . . . . . 69
Environment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 3-point linearity protocol . . . . . . . . . . . . . . . . . . . . . . . 70
Ambient temperature range . . . . . . . . . . . . . . . . . . . . . 36 5-point linearity protocol . . . . . . . . . . . . . . . . . . . . . . . 71
Ambient temperature limits . . . . . . . . . . . . . . . . . . . . . 36 Customer-specific configuration . . . . . . . . . . . . . . . . . . . 72

2 Endress+Hauser
Micropilot FMR62

Tagging (TAG) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
Services . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72

Application Packages . . . . . . . . . . . . . . . . . . . . . . . 73
Heartbeat Diagnostics . . . . . . . . . . . . . . . . . . . . . . . . . 73
Heartbeat Verification . . . . . . . . . . . . . . . . . . . . . . . . . 74
Heartbeat Monitoring . . . . . . . . . . . . . . . . . . . . . . . . . 75

Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76
Device-specific accessories . . . . . . . . . . . . . . . . . . . . . . 76
Communication-specific accessories . . . . . . . . . . . . . . . . 79
Service-specific accessories . . . . . . . . . . . . . . . . . . . . . . 80
System components . . . . . . . . . . . . . . . . . . . . . . . . . . . 80

Supplementary documentation . . . . . . . . . . . . . . . 81
Standard documentation . . . . . . . . . . . . . . . . . . . . . . . . 81
Safety Instructions (XA) . . . . . . . . . . . . . . . . . . . . . . . . 81

Endress+Hauser 3
Micropilot FMR62

Important document information


Safety symbols Symbol Meaning

DANGER!
DANGER This symbol alerts you to a dangerous situation. Failure to avoid this situation will
result in serious or fatal injury.

WARNING!
WARNING This symbol alerts you to a dangerous situation. Failure to avoid this situation can
result in serious or fatal injury.

CAUTION!
CAUTION This symbol alerts you to a dangerous situation. Failure to avoid this situation can
result in minor or medium injury.

NOTE!
NOTICE This symbol contains information on procedures and other facts which do not result in
personal injury.

Electrical symbols Symbol Meaning

Direct current

Alternating current

Direct current and alternating current

Ground connection
A grounded terminal which, as far as the operator is concerned, is grounded via a
grounding system.

Protective Earth (PE)


A terminal which must be connected to ground prior to establishing any other
connections.
The ground terminals are situated inside and outside the device:
• Inner ground terminal: Connects the protectiv earth to the mains supply.
• Outer ground terminal: Connects the device to the plant grounding system.

Symbols for Symbol Meaning


certain types of information
Permitted
Procedures, processes or actions that are permitted.

Preferred
Procedures, processes or actions that are preferred.

Forbidden
Procedures, processes or actions that are forbidden.

Tip
Indicates additional information.

Reference to documentation.

A Reference to page.

Reference to graphic.

Visual inspection.

Symbols in graphics Symbol Meaning

1, 2, 3 ... Item numbers

1. , 2. , 3. … Series of steps

A, B, C, ... Views

4 Endress+Hauser
Micropilot FMR62

Symbol Meaning

A-A, B-B, C-C, ... Sections

Hazardous area
- Indicates a hazardous area.

Safe area (non-hazardous area)


. Indicates the non-hazardous area.

Symbols at the device Symbol Meaning

Safety instructions
Observe the safety instructions contained in the associated Operating Instructions.

Temperature resistance of the connection cables


Specifies the minimum value of the temperature resistance of the connection cables.

Endress+Hauser 5
Micropilot FMR62

Terms and abbreviations


Term/abbreviation Explanation

BA Document type "Operating Instructions"

KA Document type "Brief Operating Instructions"

TI Document type "Technical Information"

SD Document type "Special Documentation"

XA Document type "Safety Instructions"

PN Nominal pressure

MWP Maximum Working Pressure


The MWP can also be found on the nameplate.

ToF Time of Flight

FieldCare Scalable software tool for device configuration and integrated plant asset management
solutions

DeviceCare Universal configuration software for Endress+Hauser HART, PROFIBUS,


FOUNDATION Fieldbus and Ethernet field devices

DTM Device Type Manager

DD Device Description for HART communication protocol

DC Relative dielectric constant εr

Operating tool The term "operating tool" is used in place of the following operating software:
FieldCare / DeviceCare, for operation via HART communication and PC

BD Blocking Distance; no signals are analyzed within the BD.

6 Endress+Hauser
Micropilot FMR62

Registered trademarks
HART®
Registered trademark of the HART Communication Foundation, Austin, USA
KALREZ®, VITON®
Registered trademark of DuPont Performance Elastomers L.L.C., Wilmington, USA
TEFLON®
Registered trademark of E.I. DuPont de Nemours & Co., Wilmington, USA
TRI CLAMP®
Registered trademark of Ladish Co. Inc., Kenosha, USA

Endress+Hauser 7
Micropilot FMR62

Function and system design


Measuring principle The Micropilot is a "downward-looking" measuring system, operating based on the frequency
modulated continuous wave method (FMCW). The antenna emits an electromagnetic wave at a
continuously varying frequency. This wave is reflected by the product and received again by the
antenna.

D
A0032017

1 FMCW principle: transmission and reflection of the continuous wave


R Reference point of measurement
D Distance between reference point and product surface

The frequency of this wave is modulated in the form of a sawtooth signal between two limit
frequencies f1 and f2:

f 1
2
f2

Δf
Δt

f1

t
A0023771

2 FMCW principle: result of frequency modulation


1 Transmitted signal
2 Received signal

This results in the following difference frequency at any time between the transmitted signal and the
received signal:

Δf = k Δt

where Δt is the run time and k is the specified increase in frequency modulation.
Δt is given by the distance D between the reference point R and the product surface:

D = (c Δt) / 2

where c is the speed of propagation of the wave.


In summary, D can be calculated from the measured difference frequency Δf. D is then used to
determine the content of the tank or silo.

8 Endress+Hauser
Micropilot FMR62

Input
Measured variable The measured variable is the distance between the reference point and the product surface. The level
is calculated based on "E", the empty distance entered. Optionally, the level can be converted to other
variables (volume, mass) by linearization (32 value pairs).

Measuring range Maximum measuring range

Device Antenna 1) Maximum measuring range

FMR62 GE: 10 m (32.8 ft)


integrated, PEEK, 20 mm / 3/4"

GF: 22 m (72 ft)


integrated PEEK, 40 mm / 1-1/2"

GM: 50 m (164 ft)


PTFE cladded flush mount 50 mm / 2"

GN: 80 m (262 ft)


PTFE cladded flush mount 80 mm / 3"

1) Feature 070 in the product structure

Usable measuring range


The usable measuring range depends on the antenna size, the medium's reflective properties, the
installation position and any possible interference reflections.
The following tables describe the groups of media as well as the achievable measuring range as a
function of application and media group. If the dielectric constant of a medium is unknown, it is
recommended to assume media group B to ensure a reliable measurement.

Media groups
Media group DC (εr) Example

A0 1.2 to 1.4 Butane, liquid nitrogen, liquefied hydrogen

A 1.4 to 1.9 non-conducting liquids, e.g. liquefied gas 1)

B 1.9 to 4 non-conducting liquids, e.g. benzene, oil, toluene, …

C 4 to 10 e.g. concentrated acids, organic solvents, esters, aniline, alcohol, acetone, …

D > 10 conducting liquids, e.g. aqueous solutions, dilute acids and alkalis

1) NH3 falls into medium group A.

For dielectric constants (DC values) of many media commonly used in various industries refer
to:
• the Endress+Hauser DC manual (CP01076F)
• the Endress+Hauser "DC Values App" (available for Android and iOS)

Endress+Hauser 9
Micropilot FMR62

FMR62

Antenna: Integrated, PEEK, 20mm/ 3/4" 1)

Storage tank Buffer tank Process tank with agitator

A0034565
A0034566 A0034567

Calm product surface (e.g. intermittent


Moving surfaces (e.g. continuous filling, Turbulent surface (e.g. filling from above, agitators, baffles)
filling, filling from bottom, immersion
from above, mixing jets)
tubes)

A0 A B C D A0 A B C D A B C D

1 1
1.5 (3.3) 1.5 (3.3) 1,5
(5) 2.5 (5) (5)
(8) 3 3
(10) (10)
5 5
(16) 6 (16)
A0034585
(20)
8 8
(26) (26)
A0034580
10
(33)
A0034575

Measuring range [m (ft)]

1) Product structure: feature 070; option GE

10 Endress+Hauser
Micropilot FMR62

FMR62

Antenna: Integrated, PEEK, 40mm/ 1-1/2" 1)

Storage tank Buffer tank Process tank with agitator

A0034565
A0034566 A0034567

Calm product surface (e.g. intermittent


Moving surfaces (e.g. continuous filling, Turbulent surface (e.g. filling from above, agitators, baffles)
filling, filling from bottom, immersion
from above, mixing jets)
tubes)

A0 A B C D A0 A B C D A0 A B C D

1
1.5 (3.3) 1,5
(5) (5)
3 3 3
(10) (10) (10)

6 6
(20) (20) 7
(23)

11 11
(36) 13 (36)
15 (43) A0034586

(49)
20
22
(66)
(72) A0034581
A0034576

Measuring range [m (ft)]

1) Product structure: feature 070; option GF

Endress+Hauser 11
Micropilot FMR62

FMR62

Antenna: PTFE cladded flush mount 50mm/2" 1)

Storage tank Buffer tank Process tank with agitator

A0034565
A0034566 A0034567

Calm product surface (e.g. intermittent


Moving surfaces (e.g. continuous filling, Turbulent surface (e.g. filling from above, agitators, baffles)
filling, filling from bottom, immersion
from above, mixing jets)
tubes)

A0 A B C D A0 A B C D A0 A B C D

2
(7)
4 4
(13) (13)

7 7
(23) (23)
7
(23)
12
13
(39)
(43) 15
(49)

23
25
(75) 28 (82)
(92) A0034587

40
44
(131) 50
(144)
(164) A0034582

A0034577

Measuring range [m (ft)]

1) Product structure: feature 070; option GM

12 Endress+Hauser
Micropilot FMR62

FMR62

Antenna: PTFE cladded flush mount 80mm/3" 1)

Storage tank Buffer tank Process tank with agitator

A0034565
A0034566 A0034567

Calm product surface (e.g. intermittent


Moving surfaces (e.g. continuous filling, Turbulent surface (e.g. filling from above, agitators, baffles)
filling, filling from bottom, immersion
from above, mixing jets)
tubes)

A0 A B C D A0 A B C D A0 A B C D

7
(23)

12
13
(39)
(43)

22
(72) 23 25
(75) (82)

40
(131) 50 45
(148) 50
(164) 60 (164) 60
65 (197) 70 (197)
(213) (230)
A0034588

80 A0034583

(262)
A0034578

Measuring range [m (ft)]

1) Product structure: feature 070; option GN

Operating frequency Approx. 80 GHz


Up to 8 devices can be installed in the same tank without interfering with each other.

Endress+Hauser 13
Micropilot FMR62

Transmission power • Peak power: 6.3 mW


• Average output power: 63 µW

14 Endress+Hauser
Micropilot FMR62

Output
Output signal HART

Signal coding FSK ±0.5 mA over current signal

Data transmission rate 1 200 Bit/s

Galvanic isolation Yes

Switch output
For HART devices, the switch output is available as an option. See product structure, feature 20:
"Power Supply, Output", option B: "2-wire; 4-20mA HART, switch output"

Switch output

Function Open collector switching output

Switching behavior Binary (conductive or non-conductive), switches when the programmable switch
point is reached

Failure mode non-conductive

Electrical connection U = 16 to 35 VDC, I = 0 to 40 mA


values

Internal resistance RI < 880 Ω


The voltage drop at this internal resistance has to be taken into account on
planning the configuration. For example, the resulting voltage at a connected
relay must be sufficient to switch the relay.

Insulation voltage floating, Insulation voltage 1 350 VDC to power supply aund 500 VAC to ground

Switch point freely programmable, separately for switch-on and switch-off point

Switching delay freely programmable from 0 to 100 s, separately for switch-on and switch-off
point

Number of switching cycles corresponds to the measuring cycle

Signal source • Level linearized


device variables • Distance
• Terminal voltage
• Electronic temperature
• Relative echo amplitude
• Diagnostic values, Advanced diagnostics

Number of switching cycles unlimited

Signal on alarm Depending on the interface, failure information is displayed as follows:


• Current output (for HART devices)
– Failsafe mode selectable (in accordance with NAMUR Recommendation NE 43):
Minimum alarm: 3.6 mA
Maximum alarm (= factory setting): 22 mA
– Failsafe mode with user-selectable value: 3.59 to 22.5 mA
• Local display
– Status signal (in accordance with NAMUR Recommendation NE 107)
– Plain text display
• Operating tool via HART communication or service interface (CDI)
– Status signal (in accordance with NAMUR Recommendation NE 107)
– Plain text display

Linearization The linearization function of the device allows the conversion of the measured value into any unit of
length or volume. Linearization tables for calculating the volume in cylindrical tanks are pre-
programmed. Other linearization tables of up to 32 value pairs can be entered manually or semi-
automatically.

Galvanic isolation All circuits for the outputs are galvanically isolated from each other.

Endress+Hauser 15
Micropilot FMR62

Protocol-specific data HART

Manufacturer ID 17 (0x11)

Device type ID 0x112B

HART specification 7.0

Device description files (DTM, DD) Information and files under:


• www.endress.com
• www.fieldcommgroup.org

HART load min. 250 Ω

HART device variables The measured values can be freely assigned to the device variables.
Measured values for PV (primary variable)
• Level linearized
• Distance
• Electronic temperature
• Relative echo amplitude
• Area of incoupling
• Analog output adv. diagnostics 1
• Analog output adv. diagnostics 2
Measured values for SV, TV, FV (second, third and fourth variable)
• Level linearized
• Distance
• Electronic temperature
• Terminal voltage
• Relative echo amplitude
• Absolute echo amplitude
• Area of incoupling
• Analog output adv. diagnostics 1
• Analog output adv. diagnostics 2

Supported functions • Burst mode


• Additional transmitter status

Wireless HART data

Minimum start-up voltage 16 V

Start-up current 3.6 mA

Start-up time 65 s

Minimum operating voltage 14.0 V

Multidrop current 4.0 mA

Set-up time 15 s

16 Endress+Hauser
Micropilot FMR62

Power supply
Terminal assignment 2-wire: 4-20mA HART

! 2- w
4-2 ire le
0 vel
H A mA
[21 RT
4-2
0m
A ]
ope
A

n Sp
a
711 re pa

HA 20mA
08x rt
xx

RT
4...
+
1 -
1 2 4 5 6

mm
2

10
+ +


# 4...20 mA
3 B

7 +
1-c 1 -
1 2 4 5 han
nel 4-2 2
ove 0m
[16
] rvo A
ltag
e pro
tec
tion
+ +


# 4...20 mA
3
A0011294

3 Terminal assignment 2-wire; 4-20mA HART


A Without integrated overvoltage protection
B With integrated overvoltage protection
1 Active barrier with power supply (e.g. RN221N): Observe terminal voltage
2 HART communication resistor (≥ 250 Ω): Observe maximum load
3 Connection for Commubox FXA195 or FieldXpert SFX350/SFX370 (via VIATOR Bluetooth modem)
4 Analog display device: Observe maximum load
5 Cable screen; observe cable specification
6 4-20mA HART (passive): Terminals 1 and 2
7 Overvoltage protection module
8 Terminal for potential equalization line
9 Cable entry

Endress+Hauser 17
Micropilot FMR62

2-wire: 4-20mA HART, switch output

10
9
8

% 2- w
4-2 ire
0
H A mA
[02 RT
PF
S
A /03
] ope
n Sp
a
711 re pa

HA 20 mA
08x rt
3+ ++ xx

31 --

RT
4...
42 +
7
1 -

mm
2 6
4-

10
+ +

-
≥250 Ω 4...20 mA
$
1 2 3 4 5 B
3+ 11 +
3 -
4-2 4
0m +
2-c
A/ 1 -
han 4-2 2
4- [17
nel
ove FIE 0mA
] rvo LD /
ltage BU
pro S
tec
tion
+ +

-
≥250 Ω 4...20 mA
$
1 2 3 4 5
A0013759

4 Terminal assignment 2-wire; 4-20mA HART, switch output


A Without integrated overvoltage protection
B With integrated overvoltage protection
1 Active barrier with power supply (e.g. RN221N): Observe terminal voltage
2 HART communication resistor (≥ 250 Ω): Observe maximum load
3 Connection for Commubox FXA195 or FieldXpert SFX350/SFX370 (via VIATOR Bluetooth modem)
4 Analog display device: Observe maximum load
5 Cable screen; observe cable specification
6 4-20mA HART (passive): Terminals 1 and 2
7 Switch output (open collector): Terminals 3 and 4
8 Terminal for potential equalization line
9 Cable entry for 4-20mA HART line
10 Cable entry for switch output line
11 Overvoltage protection module

18 Endress+Hauser
Micropilot FMR62

2-wire: 4-20mA HART, 4-20mA

14
13
12

# 2- w
4-2 ire le
0 v el
H A mA
[04 RT
4-2
0m
A /05
]
A
ope

A
n Sp

20m
a
711 re pa

HA 20mA
08x rt
xx
+

4 ...
3 -

RT
11

4 ...
4 +
1 -

mm
2
+ +

10
1 " –
-
4...20 mA
9 8 4
+ +
2 " –
-
4...20 mA
3 5 6 7 4
B
+ +
1 " –
- +
3 -
4...20 mA 4-2 4
10 0m +
9 8 4 2-c
A/ 1 -
han
nel 4- 2
[17
ove FIE 20mA
] rvo LD /
ltag
ep
B U
ro S
tec
tion
+ +
2 " –
-
4...20 mA
3 5 6 7 4
A0013923

5 Terminal assignment 2-wire, 4-20 mA HART, 4...20mA


A Without integrated overvoltage protection
B With integrated overvoltage protection
1 Connection current output 2
2 Connection current output 1
3 Supply voltage for current output 1 (e.g. RN221N); Observe terminal voltage
4 Cable screen; observe cable specification
5 HART communication resistor (≥ 250 Ω): Observe maximum load
6 Connection for Commubox FXA195 or FieldXpert SFX350/SFX370 (via VIATOR Bluetooth modem)
7 Analog display device ; observe maximum load
8 Analog display device ; observe maximum load
9 Supply voltage for current output 2 (e.g. RN221N); Obeserve terminal voltage
10 Overvoltage protection module
11 Current output 2: Terminals 3 and 4
12 Terminal for the potential equalization line
13 Cable entry for current output 1
14 Cable entry for current output 2

This version is also suited for single-channel operation. In this case, current output 1 (terminals
1 and 2) must be used.

Endress+Hauser 19
Micropilot FMR62

Connection examples for the switch output


For HART devices, the switch output is available as an option. See product structure, feature 20:
"Power Supply, Output", option B: "2-wire; 4-20mA HART, switch output"

+
3+ 1
2
Ri + 3+
-
Ri
4-
A0015909
4-
6 Connection of a relay A0015910

7 Connection of a digital input


Suitable relays (examples):
• Solid-state relay: Phoenix Contact OV-24DC/480AC/5 with mounting 1 Pull-up resistor
rail connector UMK-1 OM-R/AMS 2 Digital input
• Electromechanical relay: Phoenix Contact PLC-RSC-12DC/21

For optimum interference immunity we recommend to connect an external resistor (internal


resistance of the relay or Pull-up resistor) of < 1 000 Ω.

20 Endress+Hauser
Micropilot FMR62

Device plug connectors For the versions with fieldbus plug connector (M12 or 7/8"), the signal line can be connected
without opening the housing.

Pin assignment of the M12 plug connector


Pin Meaning
4 3 1 Signal +

2 not connected
1 2 3 Signal -

A0011175
4 Ground

Pin assignment of the 7/8" plug connector


Pin Meaning
1 3 1 Signal -

2 Signal +
2 4 3 Not connected

A0011176
4 Screen

Endress+Hauser 21
Micropilot FMR62

Supply voltage An external power supply is necessary.


Various power supply units can be ordered as an accessory from Endress+Hauser.

2-wire, 4-20mA HART, passive

"Power "Approval" 2) Terminal Maximum load R,


supply, voltage U depending on the supply voltage
output" 1) at device U0 of the power supply unit

A: • Non- 14 to 35 V R [W]
2-wire; hazardous
4-20mA • Ex nA 500
HART • Ex ic
• CSA GP

Ex ia / IS 14 to 30 V

• Ex d(ia) / XP 14 to
• Ex ic(ia) 35 V 3)
• Ex nA(ia) 0
• Ex ta / DIP 10 20 30 35 U0 [V]
14 25
  A0031745

Ex ia + Ex d(ia) / 14 to 30 V
IS + XP

1) Feature 020 in the product structure


2) Feature 010 in the product structure
3) At ambient temperatures Ta≤ -20 °C, a terminal voltage U ≥ 16 V is required to start the device with the
min. error current (3.6 mA).

"Power "Approval" 2) Terminal Maximum load R,


supply, voltage U depending on the supply voltage
output" 1) at device U0 of the power supply unit

B: • Non- 16 to 35 V R [W]
2-wire; hazardous
4-20 mA • Ex nA 500
HART, • Ex nA(ia)
switch • Ex ic
outpu • Ex ic(ia)
• Ex d(ia) / XP
• Ex ta / DIP
• CSA GP
0
• Ex ia / IS 16 to 30 V
U0 [V]
• Ex ia + Ex 10 20 30 35
16 27
d(ia) / IS + XP A0031746

1) Feature 020 in the product structure


2) Feature 010 in the product structure

22 Endress+Hauser
Micropilot FMR62

"Power "Approval" 2) Terminal Maximum load R,


supply, voltage U at depending on the supply voltage
output" 1) device U0 of the power supply unit

C: All 16 to 30 V R [W]
2-wire;
4-20mA 500
HART,
4-20mA

0
10 20 30 35 U0 [V]
16 27
A0031746

1) Feature 020 in the product structure


2) Feature 010 in the product structure

Integrated polarity reversal protection Yes

Permitted residual ripple with f = 0 to 100 Hz USS < 1 V

Permitted residual ripple with f = 100 to 10000 Hz USS < 10 mV

Power consumption "Power supply; Output" 1) Power consumption

A: 2-wire; 4-20mA HART < 0.9 W

B: 2-wire; 4-20mA HART, switch output < 0.9 W

C: 2-wire; 4-20mA HART, 4-20mA < 2 x 0.7 W

1) Feature 020 of the product structure

Current consumption
HART

Nominal current 3.6 to 22 mA the start-up current for multidrop mode can be parametrized
(is set to 3.6 mA on delivery)

Breakdown signal (NAMUR NE43) adjustable: 3.59 to 22.5 mA

Power supply failure • Configuration is retained in the HistoROM (EEPROM).


• Error messages (incl. value of operated hours counter) are stored.

Potential equalization No special measures for potential equalization are required.


If the device is designed for hazardous areas, observe the information in the documentation
"Safety Instructions" (XA).

Endress+Hauser 23
Micropilot FMR62

Cable entries Connection of power supply and signal line


To be selected in feature 050 "Electrical connection"
• Gland M20; Material dependent on the approval:
– For Non-Ex, ATEX, IECEx, NEPSI Ex ia/ic:
Plastics M20x1.5 for cable ⌀5 to 10 mm (0.2 to 0.39 in)
– For Dust-Ex, FM IS, CSA IS, CSA GP, Ex nA:
Metal M20x1.5 for cable ⌀7 to 10 mm (0.28 to 0.39 in) 1)
– For Ex d:
No gland available
• Thread
– ½" NPT
– G ½"
– M20 × 1.5
• Plug M12 / Plug 7/8"
Only available for Non-Ex, Ex ic, Ex ia

Connection of remote display FHX50


Dependent on feature 030: "Display, Operation":
• "Prepared for display FHX50 + M12 connection":
M12 socket
• "Prepared for display FHX50 + custom connection":
M16 cable gland

Cable specification • Devices without integrated overvoltage protection


Pluggable spring-force terminals for wire cross-sections 0.5 to 2.5 mm2 (20 to 14 AWG)
• Devices with integrated overvoltage protection
Screw terminals for wire cross-sections 0.2 to 2.5 mm2 (24 to 14 AWG)
• For ambient temperature TU≥60 °C (140 °F): use cable for temperature TU +20 K.

HART
• A normal device cable suffices if only the analog signal is used.
• A shielded cable is recommended if using the HART protocol. Observe grounding concept of the
plant.

Overvoltage protection If the measuring device is used for level measurement in flammable liquids which requires the use of
overvoltage protection according to DIN EN 60079-14, standard for
test procedures 60060-1 (10 kA, pulse 8/20 μs), overvoltage protection has to be ensured by an
integrated or external overvoltage protection module.

Integrated overvoltage protection


An integrated overvoltage protection module is available for 2-wire HART devices.
Product structure: Feature 610 "Accessory mounted", option NA "Overvoltage protection".

Technical data

Resistance per channel 2 × 0.5 Ω max.

Threshold DC voltage 400 to 700 V

Threshold impulse voltage < 800 V

Capacitance at 1 MHz < 1.5 pF

Nominal arrest impulse voltage (8/20 μs) 10 kA

1) The material of the gland is dependent on the housing type; GT18 (stainless steel housing): 316L (1.4404); GT19 (plastic housing) and GT20
(aluminum housing): nickel-coated brass (CuZn).

24 Endress+Hauser
Micropilot FMR62

External overvoltage protection


HAW562 or HAW569 from Endress+Hauser are suited as external overvoltage protection.
For detailed information please refer to the following documents:
• HAW562: TI01012K
• HAW569: TI01013K

Endress+Hauser 25
Micropilot FMR62

Performance characteristics
Reference operating • Temperature = +24 °C (+75 °F) ±5 °C (±9 °F)
conditions • Pressure = 960 mbar abs. (14 psia) ±100 mbar (±1.45 psi)
• Humidity = 60 % ±15 %
• Reflector: metal plate with diameter ≥ 1 m (40 in)
• No major interference reflections inside the signal beam

Reference accuracy Typical data under reference operating conditions: DIN EN IEC 61298-2 / DIN EN IEC 60770-1;
percentage values in relation to the span.

Output: digital analog 1)

Accuracy (Sum of non- Measuring distance up to 0.8 m (2.62 ft): max. ±0.03 %
linearity, nonrepeatability ±4 mm (±0.16 in)
and hysteresis) 2)
Measuring distance > 0.8 m (2.62 ft): ±1 mm (±0.04 in) ±0.02 %
3)
Non-repeatability ≤ 1 mm (0.04 in)

1) Add error of the analogous value to the digital value.


2) If the reference conditions are not met, the offset/zero point arising from the mounting conditions may be
up to ±4 mm (0.16 in). This additional offset/zero point can be compensated for by entering a correction
(parameter "level correction") during commissioning.
3) The non-repeatability is already considered in the accuracy.

Differing values in near-range applications

4 (0.16)
∆ [mm (in)]

1 (0.04)
0
-1 (-0.04)

-4 (-0.16)

R 0.8 (2.62) D [m (!)]


A0032636

8 Maximum measured error in near-range applications


Δ Maximum measured error
R Reference point of the distance measurement
D Distance from reference point of antenna

Measured value resolution Dead band according to DIN EN IEC 61298-2 / DIN EN IEC 60770-1:
• Digital: 1 mm
• Analog: 1 µA

Response time The response time can be configured. The following step response times (in accordance with
DIN EN IEC 61298-2 / DIN EN IEC 60770-1) 2) are when damping is switched off:

2) According to DIN EN IEC 61298-2 / DIN EN IEC 60770-1, the step response time is the time that elapses after an abrupt change in the input
signal until the change in the output signal has adopted 90% of the steady-state value for the first time.

26 Endress+Hauser
Micropilot FMR62

Sampling rate ≥1.3 s–1 at U ≥ 24 V

Response time < 3.6 s

Influence of ambient The measurements are performed according to DIN EN IEC 61298-3 / DIN EN IEC 60770-1
temperature • Digital (HART): average TK = 3 mm/10 K
• Analog (current output):
– Zero point (4 mA): average TK = 0.02 %/10 K
– Span (20 mA): average TK = 0.05 %/10 K

Influence of gas phase High pressure reduces the speed of propagation of the measuring signals in the gas/vapor above the
medium. This effect depends on the type of gas phase and its temperature. This results in a
systematic measured error that increases with increasing distance between the reference point of
the measurement (flange) and the surface of the product. The following table shows this measured
error for a few typical gases/vapors (with regard to the distance, a positive value means that a too
large distance is measured):

Gas phase Temperature Pressure

°C °F 1 bar (14,5 psi) 10 bar (145 psi) 25 bar (362 psi)

Air/nitrogen 20 68 0.00 % 0.22 % 0.58 %

200 392 –0.01 % 0.13 % 0.36 %

400 752 –0.02 % 0.08 % 0.29 %

Hydrogen 20 68 –0.01 % 0.10 % 0.25 %

200 392 –0.02 % 0.05 % 0.17 %

400 752 –0.02 % 0.03 % 0.11 %

Water (saturated steam) 100 212 0.02 % - -

180 356 - 2.1 % -

263 505,4 - - 4.15 %

310 590 - - -

364 687 - - -

With a known, constant pressure, it is possible to compensate for this measured error with a
linearization, for example.

Endress+Hauser 27
Micropilot FMR62

Installation
Installation conditions Mounting position

1 2 3

A0016882

• Recommended distance A wall - nozzle outer edge: ~1/6 of the container diameter. However, the
device must not under any circumstances be mounted closer than 15 cm (5.91 in) to the tank wall.
• Not in the center (2) as interference can cause signal loss.
• Not above the filling curtain (3).
• The use of a weather protection cover (1) is recommended to protect the transmitter from direct
sunlight or rain.

28 Endress+Hauser
Micropilot FMR62

Internal container fittings

A0031777

Avoid the location of internal fittings (limit switches, temperature sensors, struts, vacuum rings,
heating coils, baffles etc.) inside the signal beam. Take into account the beam angle →  30.

Endress+Hauser 29
Micropilot FMR62

Avoiding interference echoes

A0031813

Metal deflection plates installed at an angle to scatter the radar signals help prevent interference
echoes.

Optimization options
• Antenna size
The larger the antenna the smaller the beam angle α,resulting in fewer interference echoes
→  30.
• Mapping
Measurement can be optimized by electronically suppressing interference echoes.

Beam angle

α
W= 2 . D . tan_
2
D

W
A0031824

9 Relationship between beam angle α, distance D and beamwidth diameter W

The beam angle is defined as the angle α where the energy density of the radar waves reaches half
the value of the maximum energy density (3dB width). Microwaves are also emitted outside the
signal beam and can be reflected off interfering installations.

30 Endress+Hauser
Micropilot FMR62

FMR62

A0032081 A0032082

1)
Antenna integrated integrated, PTFE cladded PTFE cladded
, PEEK, 40 mm / 1-1/2" flush mount flush mount 80 mm / 3"
PEEK, 20 50 mm / 2"
mm / 3/4"

Beam angle α 14 ° 8° 7° 3°

Distance (D) Beamwidth diameter W

5 m (16 ft) 1.32 m 0.70 m (2.29 ft) 0.61 m 0.26 m (0.85 ft)
(4.33 ft) (2.00 ft)

10 m (33 ft) 2.63 m 1.40 m (4.58 ft) 1.22 m 0.52 m (1.71 ft)
(8.63 ft) (4.00 ft)

15 m (49 ft) - 2.09 m (6.87 ft) 1.83 m 0.79 m (2.59 ft)


(6.01 ft)

20 m (66 ft) - 2.79 m (9.16 ft) 2.44 m 1.05 m (3.44 ft)


(8.01 ft)

25 m (82 ft) - - 3.05 m 1.31 m (4.30 ft)


(10.02 ft)

30 m (98 ft) - - 3.66 m 1.57 m (5.15 ft)


(12.02 ft)

35 m (115 ft) - - 4.27 m 1.83 m (6.00 ft)


(14.02 ft)

40 m (131 ft) - - 4.88 m 2.09 m (6.86 ft)


(16.03 ft)

45 m (148 ft) - - 5.50 m 2.36 m (7.74 ft)


(18.03 ft)

50 m (164 ft) - - 6.11 m 2.62 m (8.60 ft)


(20.03 ft)

60 m (197 ft) - - - 3.14 m (10.30 ft)

70 m (230 ft) - - - 3.67 m (12.04 ft)

80 m (262 ft) - - - 4.19 m (13.75 ft)

1) Feature 070 in the product structure

Endress+Hauser 31
Micropilot FMR62

Measurement through a ball valve

A0034564

• Measurements can be performed through an open full bore ball valve without any problems.
• At the transitions, no gap may be left exceeding 1 mm (0.04 in).
• Diameter of opening of ball valve must always be equivalent to pipe diameter; avoid edges and
constrictions.

Measuring through plastic tank ceilings or dielectric windows


• Dielectric constant of the medium: εr ≥ 10
• The distance from the lower edge of the antenna to the tank ceiling or window should be about
100 mm (4 in).
• If possible, avoid mounting locations where condensation or build-up might occur.
• In case of outdoor mounting, the space between antenna and vessel has to be protected from the
elements.
• Do not mount any potential reflectors (e.g. pipes) outside the tank in the signal beam.

Suitable thickness of the tank ceiling or dielectric window


Material PE PTFE PP Perspex

DK (= εr) 2.3 2.1 2.3 3.1


1)
Optimum thickness 1.25 mm 1.3 mm (0.051) 1.25 mm 1.07 mm
(0.049 in) 1) (0.049 in) 1) (0.042 in) 1)

1) or an integer multiple of this value; however, take into account that the microwave transparency is
significantly reduced when increasing the thickness of the window.

Installation: integrated Radial alignment of the antenna


antenna
Based on the directional characteristic, radial alignment of the antenna is not necessary.

Information concerning nozzles


The maximum nozzle length Hmax depends on the nozzle diameter D:
Hmax

øD
A0032208

32 Endress+Hauser
Micropilot FMR62

Inner nozzle diameterD Maximum nozzle height Hmax 1)

Antenna GE 2): Antenna GF 2):


20mm / 3/4" 40mm / 1-1/2"

40 to 50 mm (1.6 to 2 in) 200 mm (8 in) 400 mm (16 in)

50 to 80 mm (2 to 3.2 in) 300 mm (12 in) 550 mm (22 in)

80 to 100 mm (3.2 to 4 in) 450 mm (18 in) 850 mm (34 in)

100 to 150 mm (4 to 6 in) 550 mm (22 in) 1 050 mm (42 in)

≥ 150 mm (6 in) 850 mm (34 in) 1 600 mm (64 in)

1) In case of longer nozzles, a reduced measuring performance is to be expected.


2) Feature 070 of the product structure

Note the following if the antenna does not project out of the nozzle:
• The end of the nozzle must be smooth and free from burrs. The edge of the nozzle should be
rounded if possible.
• Mapping must be performed.
• Please contact Endress+Hauser for applications with nozzles that are higher than indicated in
the table.

Information concerning threaded connections


• When screwing in, turn by the hex bolt only.
• Tool: open-ended wrench 36 mm (Sensor 3/4");
open-ended wrench 55 mm (Sensor 1 1/2")
• Maximum permissible torque: 50 Nm (36 lbf ft)

Installation: flush mount Radial alignment of the antenna


antenna
Based on the directional characteristic, radial alignment of the antenna is not necessary.

Information concerning nozzles


Hmax

øD
A0032206

Inner nozzle diameterD Maximum nozzle height Hmax 1)

Antenna GM 2): Antenna GN 2):


50mm / 2" 80mm / 3"

50 to 80 mm (2 to 3.2 in) 600 mm (24 in) -

80 to 100 mm (3.2 to 4 in) 1 000 mm (40 in) 1 750 mm (70 in)

Endress+Hauser 33
Micropilot FMR62

Inner nozzle diameterD Maximum nozzle height Hmax 1)

Antenna GM 2): Antenna GN 2):


50mm / 2" 80mm / 3"

100 to 150 mm (4 to 6 in) 1 250 mm (50 in) 2 200 mm (88 in)

≥ 150 mm (6 in) 1 850 mm (74 in) 3 300 mm (132 in)

1) In case of longer nozzles, a reduction of the measuring performance is to be expected.


2) Merkamal 070 der Produktstruktur

Note the following if the antenna does not project out of the nozzle:
• The end of the nozzle must be smooth and free from burrs. The edge of the nozzle should be
rounded if possible.
• Mapping must be performed.
• Please contact Endress+Hauser for applications with nozzles that are higher than indicated in
the table.

Mounting cladded flanges


Note the following for cladded flanges:
• Use the same number of flange screws as the number of flange bores provided.
• Tighten the screws with the necessary torque (see Table).
• Retighten after 24 hours or after the first temperature cycle.
• Depending on the process pressure and temperature, check and retighten the screws, where
necessary, at regular intervals.
The PTFE flange cladding normally acts simultaneously as a seal between the nozzle and the
device flange.

Flange size Number of screws Recommended tightening torque [Nm]

Minimum Maximum

EN

DN50/PN16 4 45 65

DN80/PN16 8 40 55

DN100/PN16 8 40 60

DN150/PN16 8 75 115

ASME

2"/150lbs 4 40 55

3"/150lbs 4 65 95

4"/150lbs 8 45 70

6"/150lbs 8 85 125

JIS

10K 50A 4 40 60

10K 80A 8 25 35

10K 100A 8 35 55

10K 150A 8 75 115

34 Endress+Hauser
Micropilot FMR62

Container with heat


insulation

A0032207

If process temperatures are high, the device should be included in the usual container insulation
system (2) to prevent the electronics from heating as a result of thermal radiation or convection. The
insulation should not be higher than the neck of the device (1).

Endress+Hauser 35
Micropilot FMR62

Environment
Ambient temperature range Measuring device –40 to +80 °C (–40 to +176 °F)

Local display –20 to +70 °C (–4 to +158 °F), the readability of the display may be impaired at
temperatures outside the temperature range.

Outdoor operation in strong sunlight:


• Mount the device in the shade.
• Avoid direct sunlight, particularly in warm climatic regions.
• Use a weather protection cover (see accessories).

Ambient temperature limits The following diagrams only consider functional aspects. Additional restrictions may apply for
certified device versions. See the separate Safety Instructions for more information →  81.
In the event of temperature (Tp) at the process connection, the permitted ambient temperature (Ta)
is reduced as indicated in the following diagram (temperature derating) in the table header.

FMR62
Antenna 1)
• GE:
Integrated, PEEK, 3/4"
• GF:
Integrated, PEEK, 1-1/2" Ta
• GM: P1 P2
PTFE cladded flush mount DN50
• GN:
PTFE cladded flush mount DN80 P3

Seal 2) Tp
• A6: P5 P4
FKM Viton GLT, –40 to 200 °C (–40 to 392 °F)
A0032024
• C2:
FFKM Kalrez, –20 to 200 °C (–4 to 392 °F)
• F6:
PTFE cladded, –40 to 200 °C (–40 to 392 °F)
Temperature specifications: °C (°F)

Housing type 3) P1 P2 P3 P4 P5
Tp Ta Tp Ta Tp Ta Tp Ta Tp Ta

B: –40 76 76 76 200 63 200 –40 –40 –40


GT18 two-chamber (–40) (168.8) (168.8) (168.8) (392) (145.4) (392) (–40) (–40) (–40)
316L

A: –40 60 60 60 200 42 200 –40 –40 –40


GT19 two-chamber (–40) (140) (140) (140) (392) (107.6) (392) (–40) (–40) (–40)
Plastic PBT

C: –40 76 76 76 200 68 200 –40 –40 –40


GT20 two-chamber (–40) (168.8) (168.8) (168.8) (392) (154.4) (392) (–40) (–40) (–40)
Aluminum, coated

1) Feature 070 in the product structure


2) Feature 090 in the product structure
3) Feature 040 in the product structure

36 Endress+Hauser
Micropilot FMR62

FMR62
Antenna 1)
• GE:
Integrated, PEEK, 3/4"
• GF:
Integrated, PEEK, 1-1/2"
• GM:
Ta
PTFE cladded flush mount DN50
• GN: P1 P2 P2+
PTFE cladded flush mount DN80
P3
Seal 2)
• A5:
FKM Viton GLT,
Tp
P5 P4
–40 to 150 °C (–40 to 302 °F)
• C1: A0032025

FFKM Kalrez,
–40 to 150 °C (–40 to 302 °F)
• F5:
PTFE cladded,
–40 to 150 °C (–40 to 302 °F)
Temperature specifications: °C (°F)

Housing type 3) P1 P2 P2+ P3 P4 P5

Tp Ta Tp Ta Tp Ta Tp Ta Tp Ta Tp Ta

B: –40 76 76 76 109 71 150 47 150 –40 –40 –40


GT18 two-chamber (–40) (168.8)(168.8)(168.8) (228.2)(159.8)(302) (116.6) (302) (–40) (–40) (–40)
316L

A: –40 60 60 60 127 45 150 24 150 –40 –40 –40


GT19 two-chamber (–40) (140) (140) (140) (260.6)(113) (302) (75.2) (302) (–40) (–40) (–40)
Plastic PBT

C: –40 76 76 76 112 72 150 55 150 –40 –40 –40


GT20 two-chamber (–40) (168.8)(168.8)(168.8) (233.6)(161.6)(302) (131) (302) (–40) (–40) (–40)
Aluminum, coated

1) Feature 070 in the product structure


2) Feature 090 in the product structure
3) Feature 040 in the product structure

Storage temperature –40 to +80 °C (–40 to +176 °F)

Climate class DIN EN 60068-2-38 (test Z/AD)

Altitude according to • Generally up to 2 000 m (6 600 ft) above MSL.


IEC61010-1 Ed.3 • Above 2 000 m (6 600 ft) if the following conditions are met:
– Ordering feature 020 "Power supply; Output" = A, B, C, E or G (2-wire versions)
– Supply voltage U < 35 V
– Supply voltage of overvoltage category 1

Degree of protection • With closed housing tested according to:


– IP68, NEMA6P (24 h at 1.83 m under water surface)
– For plastic housing with transparent cover (display module): IP68 (24 h at 1.00 m under water
surface) 3)
– IP66, NEMA4X
• With open housing: IP20, NEMA1
• Display module: IP22, NEMA2
Degree of protection IP68 NEMA6P applies for M12 PROFIBUS PA plugs only when the
PROFIBUS cable is plugged in and is also rated IP68 NEMA6P.

3) This restriction is valid if the following options of the product structure have been selected at the same time: 030 ("Display, Operation") = C
("SD02") or E ("SD03"); 040 ("Housing") = A ("GT19").

Endress+Hauser 37
Micropilot FMR62

Vibration resistance DIN EN 60068-2-64 IEC 60068-2-64 at 5 to 2 000 Hz: 1.5 (m/s2)2/Hz
A limited vibration resistance applies according
DIN EN 60068-2-64/IEC 60068-2-64 at 5 to 2 000 Hz of 0.39 (m/s2)2/Hz,
if the following order features are selected in the product structure at the same time:
• 040 ("Housing"): B ("GT18 two-chamber, 316L)
and
• 090 ("Seal"):
– A6 ("FKM Viton GLT, –40 to 200 °C (–40 to 392 °F), incl. gas-tight feedthrough")
or
– C2 ("FKM Viton GLT, –40 to 200 °C (–40 to 392 °F), incl. gas-tight feedthrough")
or
– F6 ("FKM Viton GLT, –40 to 200 °C (–40 to 392 °F), incl. gas-tight feedthrough")

Electromagnetic Electromagnetic compatibility in accordance with all of the relevant requirements outlined in the
compatibility (EMC) EN 61326 series and NAMUR Recommendation EMC (NE 21). For details, please refer to the
Declaration of Conformity 4).
A normal device cable suffices if only the analog signal should be used. Use a shielded cable for
digital communication (HART/ PA/ FF).
Maximum measured error during EMC testing: <0.5 % of the span. By way of derogation, for devices
with a plastic housing and see-through lid (integrated display SD02 or SD03) the measured error can
be up to 2 % of the span in the event of strong electromagnetic radiation in the 1 to 2 GHz frequency
range.

4) Available for download at www.de.endress.com.

38 Endress+Hauser
Micropilot FMR62

Process
Process temperature, process
The pressure ranges indicated can be reduced by the choice of process connection. The nominal
pressure
pressure (PN) indicated on the nameplate refers to a reference temperature of 20 °C, and of
100 °F for ASME flanges. Observe pressure-temperature dependency.
Please refer to the following standards for the pressure values permitted at higher
temperatures:
• EN 1092-1: 2001 Tab. 18
In terms of their stability-temperature property, the materials 1.4435 and 1.4404 are
grouped in EN 1092-1 table 18 under 13E0. The chemical composition of the two materials
can be identical.
• ASME B 16.5a – 1998 Tab. 2-2.2 F316
• ASME B 16.5a – 1998 Tab. 2.3.8 N10276
• JIS B 2220

FMR62, integrated antenna, PEEK, 150 °C (302 °F)

[bar] ([psi]) p

1 2
20 (290)

0 (0)
-1 (-14.5) Tp
-40 -20 0 +150 [°C]
(-40) (-4) (+32) (+302) ([°F])
A0032182

 10 FMR62: Permitted range for process temperature and process pressure, integrated antenna, PEEK (feature
070: GE, GF), 150 °C (302 °F)
1 Feature 90, seal: A5, FKM Viton GLT
2 Feature 90, seal: C1, FFKM Kalrez

FMR62, integrated antenna, PEEK, feature 070: GE, GF


Feature 100 "Process connection" Feature 90 Process temperature Process pressure range
"Seal" range

• GDJ: A5: –40 to +150 °C


Thread ISO228 G3/4, 316L FKM Viton GLT (–40 to +302 °F)
• GGJ:
prel =
Thread ISO228 G1-1/2, 316L
–1 to 20 bar
• RDJ: C1: –20 to +150 °C (–14.5 to 290 psi) 1)
Thread ANSI MNPT3/4, 316L FFKM Kalrez (–4 to +302 °F)
• RGJ:
Thread ANSI MNPT1-1/2, 316L

1) The pressure range may be further restricted in the event of a CRN approval

Endress+Hauser 39
Micropilot FMR62

FMR62, integrated antenna, PEEK, 200 °C (392 °F)

[bar] ([psi]) p

1 2
20 (290)

0 (0)
-1 (-14.5) Tp
-40 -20 0 +200 [°C]
(-40) (-4) (+32) (+392) ([°F])
A0032183

 11 FMR62: Permitted range for process temperature and process pressure, integrated antenna, PEEK (feature
070: GE, GF), 200 °C (392 °F)
1 Feature 90, seal: A6, FKM Viton GLT
2 Feature 90, seal: C2, FFKM Kalrez

FMR62, integrated antenna, PEEK , feature 070: GE, GF


Feature 100 "Process connection" Feature 90 Process temperature Process pressure range
"Seal" range

• GDJ: A6: –40 to +200 °C


Thread ISO228 G3/4, 316L FKM Viton GLT (–40 to +392 °F)
• GGJ:
prel =
Thread ISO228 G1-1/2, 316L
–1 to 20 bar
• RDJ: C2: –20 to +200 °C (–14.5 to 290 psi) 1)
Thread ANSI MNPT3/4, 316L FFKM Kalrez (–4 to +392 °F)
• RGJ:
Thread ANSI MNPT1-1/2, 316L

1) The pressure range may be further restricted in the event of a CRN approval

FMR62, Tri-Clamp 2" process connection

[bar] ([psi]) p

1 2
16 (232)

0 (0)
-1 (-14.5) Tp
-40 0 +150 +200 [°C]
(-40) (+32) (+302) (+392) ([°F])
A0032618

 12 FMR62: Permitted range for process temperature and process pressure, Tri-Clamp 2" process connection
1 Feature 90, seal: F5
2 Feature 90, seal: F6

40 Endress+Hauser
Micropilot FMR62

FMR62, Tri-Clamp 2" process connection


Feature 100 "Process Feature 90 Process temperature range Process pressure range
connection" "Seal"

TDK: F5: –40 to +150 °C


Tri-Clamp ISO2852 PTFE cladded (–40 to +302 °F) prel =
DN40-51 (2") –1 to 16 bar
F6: –40 to +200 °C (–14.5 to 232 psi) 1)
PTFE cladded (–40 to +392 °F)

1) The pressure range may be further restricted in the event of a CRN approval

FMR62, Tri-Clamp 3" or Tri-Clamp 4" process connection

[bar] ([psi]) p

1 2
14 (203)

0 (0)
-1 (-14.5) Tp
-40 0 +150 +200 [°C]
(-40) (+32) (+302) (+392) ([°F])
A0032619

 13 FMR62: Permitted range for process temperature and process pressure, Tri-Clamp 3" or Tri-Clamp 4"
process connection
1 Feature 90, seal: F5
2 Feature 90, seal: F6

FMR62, Tri-Clamp 3" or Tri-Clamp 4" process connection


Feature 100 "Process connection" Feature 90 Process temperature Process pressure range
"Seal" range

• TFK: F5: –40 to +150 °C


Tri-Clamp ISO2852 DN70-76.1 PTFE cladded (–40 to +302 °F)
prel =
(3")
–1 to 14 bar
• THK: F6: –40 to +200 °C (–14.5 to 203 psi) 1)
Tri-Clamp ISO2852 DN101.6 PTFE cladded (–40 to +392 °F)
(4")

1) The pressure range may be further restricted in the event of a CRN approval

Endress+Hauser 41
Micropilot FMR62

FMR62, flange or DIN11851 process connection, PTFE flush mount

[bar] ([psi]) p

1 2
25 (362.6)

0 (0)
-1 (-14.5) Tp
-40 0 +150 +200 [°C]
(-40) (+32) (+302) (+392) ([°F])
A0032184

 14 FMR62: Permitted range for process temperature and process pressure, flange or DIN11851 process
connection
1 Feature 90, seal: F5
2 Feature 90, seal: F6

FMR62, flange or DIN11851 process connection


Feature 100 "Process connection" Feature 90 Process Process pressure
"Seal" temperature range range

• AFK: F5:
–40 to +150 °C
NPS 2" Cl.150 RF, PTFE > 316/316L PTFE
(–40 to +302 °F)
• AGK: cladded
NPS 3" Cl.150 RF, PTFE > 316/316L
• AHK:
NPS 4" Cl.150 RF, PTFE > 316/316L
• AJK:
NPS 6" Cl.150 RF, PTFE > 316/316L
• CFK:
DN50 PN10/16 B1, PTFE > 316L
• CGK:
DN80 PN10/16 B1, PTFE > 316L
• CHK: prel =
DN100 PN10/16 B1, PTFE > 316L –1 to 25 bar
• CJK: F6: (–14.5 to
DN150 PN10/16 B1, PTFE > 316L –40 to +200 °C 362.6 psi) 1)
PTFE
• KFK: (–40 to +392 °F)
cladded
10K 50A RF, PTFE > 316L
• KGK:
10K 80A RF, PTFE > 316L
• KHK:
10K 100A RF, PTFE > 316L
• KJK:
10K 150A RF, PTFE > 316L
• MRK:
DIN11851 DN50 PN25 slotted nut, PTFE > 316L
• MTK:
DIN11851 DN80 PN25 slotted nut, PTFE > 316L

1) The pressure range may be further restricted in the event of a CRN approval

Dielectric constant For liquids


εr ≥ 1.9
Please contact Endress+Hauser for applications with lower dielectric constants than indicated.
For dielectric constants (DC values) of many media commonly used in various industries refer
to:
• the Endress+Hauser DC manual (CP01076F)
• the Endress+Hauser "DC Values App" (available for Android and iOS)

42 Endress+Hauser
Micropilot FMR62

Mechanical construction
Dimensions Dimensions of the electronics housing

R110 98 (3.86)*
78 (3.07) 90 (3.54)

07)
(4.
3.5

146 (5.75)
ø108.5 (4.27)

142 (5.59)
115.25 (4.54)
ø10
A0011666

 15 Housing GT18 (316L); Dimensions in mm (in)


*for devices with integrated overvoltage protection.

R110
99 (3.9)*
78 (3.07) 90 (3.54)
)
.17
6 (4

144 (5.67)
ø106 (4.17)
ø10

113.5 (4.47)
A0011346

 16 Housing GT19 (Plastics PBT); Dimensions in mm (in)


*for devices with integrated overvoltage protection.

R110 98 (3.86)*
78 (3.07) 90 (3.54)
07)
(4.

ø112 (4.41)

145.5 (5.73)
3.5

141.5 (5.57)
ø108.5 (4.27)
ø10

61 (2.4)

A0020751

 17 Housing GT20 (Alu coated); Dimensions in mm (in)


*for devices with integrated overvoltage protection.

Endress+Hauser 43
Micropilot FMR62

FMR62: integrated antenna, PEEK, 20mm / 3/4"

Relevant ordering features


Ordering feature Options

070: Antenna GE: Integrated, PEEK, 20mm/3/4"

090: Seal • A5: FKM Viton GLT, -40...150°C / -40...302°F


• A6: FKM Viton GLT, -40...200°C / -40...392°F, incl. gas-tight feed through
• C1: FFKM Kalrez, -20...150°C / -4...302°F
• C2: FFKM Kalrez, -20...200°C / -4...392°F, incl. gas-tight feed through

100: Process Connection • GDJ: Thread ISO228 G3/4, 316L


• RDJ: Thread ANSI MNPT3/4, 316L

1
A B

186 (7.32)
143 (5.63)

22 (0.87)

R
ø32.2 (1.27)
ø23.8 (0.94)

A0031557

 18 Dimensions: mm (in)
A Seal: FKM Viton GLT, -40 to 150°C/-40 to 302°F or FFKM Kalrez, -20...150oC/-4...302°F
B Seal: FKM Viton GLT, -40 to 200°C/-40 to 392°F or FFKM Kalrez, -20...200oC/-4...392°F
R Reference point of the measurement
1 Bottom edge of housing

44 Endress+Hauser
Micropilot FMR62

FMR62: integrated antenna, PEEK, 40mm / 1-1/2"

Relevant ordering features


Ordering feature Options

070: Antenna GF: Integrated, PEEK, 40mm/1-1/2"

090: Seal • A5: FKM Viton GLT, -40...150°C / -40...302°F


• A6: FKM Viton GLT, -40...200°C / -40...392°F, incl. gas-tight feed through
• C1: FFKM Kalrez, -20...150°C / -4...302°F
• C2: FFKM Kalrez, -20...200°C / -4...392°F, incl. gas-tight feed through

100: Process Connection • GGJ: Thread ISO228 G1-1/2, 316L


• RGJ: Thread ANSI MNPT1-1/2, 316L

1
A B

227 (8.94)
184 (7.24)

30 (1.18)

ø54.8 (2.18)

ø42.5 (1.67)

A0032787

 19 Dimensions: mm (in)
A Seal: FKM Viton GLT, -40 to 150°C/-40 to 302°F or FFKM Kalrez, -20...150oC/-4...302°F
B Seal: FKM Viton GLT, -40 to 200°C/-40 to 392°F or FFKM Kalrez, -20...200oC/-4...392°F
R Reference point of the measurement
1 Bottom edge of housing

Endress+Hauser 45
Micropilot FMR62

FMR62: flush mount antenna with sanitary adapter DIN11851, PTFE cladded

Relevant ordering features


Ordering feature Options

070: Antenna • GM: PTFE cladded flush mount 50mm/2"


• GN: PTFE cladded flush mount 80mm/3"

090: Seal • F5: PTFE cladded, -40...150°C / -40...302°F


• F6: PTFE cladded, -40...200°C / -40...392°F, incl. gas-tight feed through

100: Process Connection • MRK: DIN11851 DN50 PN25 slotted nut, PTFE>316L
• MTK: DIN11851 DN80 PN25 slotted nut, PTFE>316L

A B 1

L2
L1

L3

L4
R

øD1

øD2
A0032175

 20 Dimensions: mm (in)
A Seal: PTFE cladded, -40 to 150°C/-40 to 302°F
B Seal: PTFE cladded, -40 to 200°C/-40 to 392°F
R Reference point of the measurement
1 Bottom edge of housing

Feature 100 "Process øD1 øD2 L1 L2 L3 L4


connection"

MRK:
48 mm 65.5 mm 148 mm 191 mm 5 mm 19 mm
DN50 PN25 slotted nut,
(1.89 in) (2.58 in) (5.83 in) (7.52 in) (0.20 in) (0.75 in)
PTFE>316L

MTK:
75 mm 97 mm 161 mm 204 mm 6 mm 32 mm
DN80 PN25 slotted nut,
(2.95 in) (3.82 in) (6.33 in) (8.03 in) (0.24 in) (1.26 in)
PTFE>316L

46 Endress+Hauser
Micropilot FMR62

FMR62: flush-mount antenna with Tri-Clamp ISO2852, PTFE cladded

Relevant ordering features


Ordering feature Options

070: Antenna • GM: PTFE cladded flush mount 50mm/2"


• GN: PTFE cladded flush mount 80mm/3"

090: Seal • F5: PTFE cladded, -40...150°C / -40...302°F


• F6: PTFE cladded, -40...200°C / -40...392°F, incl. gas-tight feed through

100: Process Connection • TDK: Tri-Clamp ISO2852 DN40-51 (2"), PTFE>316L


• TFK: Tri-Clamp ISO2852 DN70-76.1 (3"), PTFE>316L
• TDK: Tri-Clamp ISO2852 DN101.6 (4"), PTFE>316L

A B 1

L2
L1

2.6 (0.10)

1.6 (0.06) R

L4
øD1

øD2

øD3
A0032176

 21 Dimensions: mm (in)
A Seal: PTFE cladded, -40 to 150°C/-40 to 302°F
B Seal: PTFE cladded, -40 to 200°C/-40 to 392°F
R Reference point of the measurement
1 Bottom edge of housing

Feature 70 "Antenna" øD1 L1 L2 L4

GM:
48 mm (1.89 in) 145 mm (5.71 in) 188 mm (7.40 in) 19 mm (0.75 in)
PTFE cladded flush mount DN50

GN:
75 mm (2.95 in) 158 mm (6.22 in) 201 mm (7.91 in) 32 mm (1.26 in)
PTFE cladded flush mount DN80

Feature 100 "Process connection" øD2 øD3

TDK:
56.5 mm (2.22 in) 64 mm (2.52 in)
DN40-51 (2")

TFK:
83.5 mm (3.29 in) 91 mm (3.58 in)
DN70-76.1 (3")

THK:
110 mm (4.33 in) 119 mm (4.69 in)
DN101.6 (4")

Endress+Hauser 47
Micropilot FMR62

FMR62: flush mount antenna with flange EN1092-1, ASME B16.5 or JIS B2220; PTFE cladded

Relevant ordering features


Ordering feature Options

070: Antenna • GM: PTFE cladded flush mount 50mm/2"


• GN: PTFE cladded flush mount 80mm/3"

090: Seal • F5: PTFE cladded, -40...150°C / -40...302°F


• F6: PTFE cladded, -40...200°C / -40...392°F, incl. gas-tight feed through

100: Process Connection • AFK: NPS 2" Cl.150, PTFE>316/316L flange ASME B16.5
• AGK: NPS 3" Cl.150, PTFE>316/316L flange ASME B16.5
• AHK: NPS 4" Cl.150, PTFE>316/316L flange ASME B16.5
• AJK: NPS 6" Cl.150, PTFE>316/316L flange ASME B16.5
• CFK: DN50 PN10/16, PTFE>316L flange EN1092-1
• CGK: DN80 PN10/16, PTFE>316L flange EN1092-1
• CHK: DN100 PN10/16, PTFE>316L flange EN1092-1
• CJK: DN150 PN10/16, PTFE>316L flange EN1092-1
• KFK: 10K 50A, PTFE>316L flange JIS B2220
• KGK: 10K 80A, PTFE>316L flange JIS B2220
• KHK: 10K 100A, PTFE>316L Flansch JIS B2220
• KJK: 10K 150A, PTFE>316L flange JIS B2220

1
A B

L2
L1

4 (0.16)

L3

R
L4

øD1

øD2

øD3

A0032177

 22 Dimensions: mm (in)
A Seal: PTFE cladded, -40 to 150°C/-40 to 302°F
B Seal: PTFE cladded, -40 to 200°C/-40 to 392°F
R Reference point of the measurement
1 Bottom edge of housing

Feature 70 "Antenna" øD1 L1 L2 L4

GM:
48 mm (1.89 in) 147 mm (5.79 in) 186 mm (7.32 in) 19 mm (0.75 in)
PTFE cladded flush mount DN50

GN:
75 mm (2.95 in) 159 mm (6.26 in) 202 mm (7.95 in) 32 mm (1.26 in)
PTFE cladded flush mount DN80

48 Endress+Hauser
Micropilot FMR62

Feature 100 "Process connection" øD2 øD3 L3

AFK:
92 mm (3.62 in) 150 mm (5.91 in) 17.5 mm (0.69 in)
NPS 2" Cl.150, PTFE>316/316L

AGK:
127 mm (5.00 in) 190 mm (7.48 in) 22.3 mm (0.88 in)
NPS 3" Cl.150, PTFE>316/316L

AHK:
158 mm (6.22 in) 230 mm (9.06 in) 22.3 mm (0.88 in)
NPS 4" Cl.150, PTFE>316/316L

AJK:
212 mm (8.35 in) 280 mm (11.02 in) 23.9 mm (0.94 in)
NPS 6" Cl.150, PTFE>316/316L

CFK:
102 mm (4.02 in) 165 mm (6.50 in) 18 mm (0.71 in)
DN50 PN10/16, PTFE>316L

CGK:
138 mm (5.43 in) 200 mm (7.87 in) 20 mm (0.79 in)
DN80 PN10/16, PTFE>316L

CHK:
158 mm (6.22 in) 220 mm (8.66 in) 20 mm (0.79 in)
DN100 PN10/16, PTFE>316L

CJK:
212 mm (8.35 in) 285 mm (11.22 in) 22 mm (0.87 in)
DN150 PN10/16, PTFE>316L

KFK:
96 mm (3.78 in) 155 mm (6.10 in) 16 mm (0.63 in)
10K 50A, PTFE>316L

KGK:
127 mm (5.00 in) 185 mm (7.28 in) 18 mm (0.71 in)
10K 80A, PTFE>316L

KHK:
151 mm (5.94 in) 210 mm (8.27 in) 18 mm (0.71 in)
10K 100A, PTFE>316L

KJK:
212 mm (8.35 in) 280 mm (11.02 in) 22 mm (0.87 in)
10K 150A, PTFE>316L

Endress+Hauser 49
Micropilot FMR62

Weight Housing
Part Weight

GT18 housing - stainless steel Approx. 4.5 kg (9.9 lb)

GT19 housing - plastic Approx. 1.2 kg (2.7 lb)

GT20 housing - aluminum Approx. 1.9 kg (4.2 lb)

Antenna and process connection


Device Antenna 1) Weight of antenna /
process connection

GE: Max. 1.5 kg (3.31 lb) + flange weight 2)


Integrated, PEEK, 3/4"

GF: Max. 2.3 kg (5.07 lb) + flange weight 2)


Integrated, PEEK, 1-1/2"
FMR62
GM: Max. 1.7 kg (3.75 lb) + flange weight 2)
PTFE cladded flush mount DN50

GN: Max. 2.9 kg (6.39 lb) + flange weight 2)


PTFE cladded flush mount DN80

1) Order code 070


2) For flange weights (316/316L) see Technical Information TI00426F.

50 Endress+Hauser
Micropilot FMR62

Materials: GT18 housing


1
(stainless steel, corrosion-
resistant) 2.1
2.2

5.2
6
5.1
7
4 3 9 8
A0013788

No. Part Material

1 Housing CF3M similar to 316L/1.4404

2.1 Cover of the electronics compartment • Cover: CF3M (similar to 316L/1.4404)


• Window: glass
• Cover seal: NBR
• Seal of the window: NBR
• Thread-coating: Graphite-based lubricant varnish

2.2 Cover of the terminal compartment • Cover: CF3M (similar to 316L/1.4404)


• Cover seal: NBR
• Thread-coating: Graphite-based lubricant varnish

3 Cover lock • Screw: A4


• Clamp: 316L (1.4404)

4 Lock at the housing neck • Screw: A4-70


• Clamp: 316L (1.4404)

5.1 Dummy plug, cable gland, adapter or plug • Dummy plug, depending on the device version:
(depending on the device version) – PE
– PBT-GF
• Cable gland: 316L (1.4404) or nickel-plated brass
• Adapter: 316L (1.4404/1.4435)
• Seal: EPDM
• M12 plug: Nickel-plated brass 1)
• 7/8" plug: 316 (1.4401) 2)

5.2 Dummy plug, cable gland or adapter (depending on • Dummy plug: 316L (1.4404)
the device version) • Cable gland: 316L (1.4404) or nickel-plated brass
• Adapter: 316L (1.4404/1.4435)
• Seal: EPDM

6 Dummy plug or M12 socket (depending on the • Dummy plug: 316L (1.4404)
device version) • M12 socket: 316L (1.4404)

7 Pressure relief stopper 316L (1.4404)

8 Ground terminal • Screw: A4


• Spring washer: A4
• Clamp: 316L (1.4404)
• Holder: 316L (1.4404)

9 Nameplate • Plate: 316L (1.4404)


• Groove pin: A4 (1.4571)

1) For the version with M12 plug the sealing material is Viton.
2) For the version with 7/8" plug, the sealing material is NBR.

Endress+Hauser 51
Micropilot FMR62

Materials: GT19 housing


1
(plastic)
2.1
2.2

5.2
6
5.1
7
4 9 8
A0013788

No. Part Material

1 Housing PBT

2.1 Cover of the electronics compartment • Cover glass: PC


• Cover frame: PBT-PC
• Cover seal: EPDM
• Thread-coating: Graphite-based lubricant varnish

2.2 Cover of the terminal compartment • Cover: PBT


• Cover seal: EPDM
• Thread-coating: Graphite-based lubricant varnish

4 Lock at the housing neck • Screw: A4-70


• Clamp: 316L (1.4404)

5.1 Dummy plug, cable gland, adapter or plug • Dummy plug, depending on the device version:
(depending on the device version) – PE
– PBT-GF
• Cable gland, depending on the device version:
– Nickel-plated brass (CuZn)
– PA
• Adapter: 316L (1.4404/1.4435)
• Seal: EPDM
• M12 plug: Nickel-plated brass 1)
• 7/8" plug: 316 (1.4401) 2)

5.2 Dummy plug, cable gland or adapter (depending on • Dummy plug, depending on the device version:
the device version) – PE
– PBT-GF
– Nickel-plated steel
• Cable gland, depending on the device version:
– Nickel-plated brass (CuZn)
– PA
• Adapter: 316L (1.4404/1.4435)
• Seal: EPDM

6 Dummy plug or M12 socket (depending on the • Dummy plug: Nickel-plated brass (CuZn)
device version) • M12 socket: Nickel-plated GD-Zn

7 Pressure relief stopper Nickel-plated brass (CuZn)

8 Ground terminal • Screw: A2


• Spring washer: A4
• Clamp: 304 (1.4301)
• Holder: 304 (1.4301)

9 Adhesive nameplate Plastic

1) For the version with M12 plug the sealing material is Viton.
2) For the version with 7/8" plug, the sealing material is NBR.

52 Endress+Hauser
Micropilot FMR62

Materials: GT20 housing


1
(die-cast aluminum, powder-
coated) 2.1
2.2

5.2
6
5.1
7
4 3 9 8
A0013788

Nr. Part Material

1 Housing, RAL 5012 (blue) • Housing: AlSi10Mg(<0,1% Cu)


• Coating: Polyester

2.1 Cover of the electronics compartment; RAL 7035 • Cover: AlSi10Mg(<0,1% Cu)
(gray) • Window: Glass
• Cover seal: NBR
• Seal of the window: NBR
• Thread-coating: Graphite-based lubricant varnish

2.2 Cover of the terminal compartment; RAL 7035 • Cover: AlSi10Mg(<0,1% Cu)
(gray) • Cover seal: NBR
• Thread-coating: Graphite-based lubricant varnish

3 Cover lock • Screw: A4


• Clamp: 316L (1.4404)

4 Lock at the housing neck • Screw: A4-70


• Clamp: 316L (1.4404)

5.1 Dummy plug, cable gland, adapter or plug • Dummy plug, depending on the device version:
(depending on the device version) – PE
– PBT-GF
• Cable gland, depending on the device version:
– Nickel-plated brass (CuZn)
– PA
• Adapter: 316L (1.4404/1.4435)
• Seal: EPDM
• M12 plug: Nickel-plated brass 1)
• 7/8" plug: 316 (1.4401) 2)

5.2 Dummy plug, cable gland or adapter (depending on • Dummy plug, depending on the device version:
the device version) – PE
– PBT-GF
– Nickel-plated steel
• Cable gland, depending on the device version:
– Nickel-plated brass (CuZn)
– PA
• Adapter: 316L (1.4404/1.4435)
• Seal: EPDM

6 Dummy plug or M12 socket (depending on the • Dummy plug : Nickel-plated brass (CuZn)
device version) • M12 socket: Nickel-plated GD-Zn

7 Pressure relief stopper Nickel-plated brass (CuZn)

Endress+Hauser 53
Micropilot FMR62

Nr. Part Material

8 Ground terminal • Screw: A2


• Spring washer: A2
• Clamp: 304 (1.4301)
• Holder: 304 (1.4301)

9 Adhesive nameplate Plastic

1) For the version with M12 plug the sealing material is Viton.
2) For the version with 7/8" plug, the sealing material is NBR.

Materials: antenna and FMR62, integrated antenna


process connection

5
1
A0032019

No. Component part Material

1 Antenna Antenna: PEEK


Antenna seal: Viton (FKM); KALREZ (FFKM)

2 Antenna adapter 316L / 1.4404

3 housing adapter 316L / 1.4404

4 Housing seal EPDM

5 Process connection 316L / 1.4404

FMR62; antenna cladded, flush mount

4 4 4

3 3 3

2 2 2
5 5 5
6
1 1 1
A0031815

No. Component part Material

1 Antenna PTFE
Antenna seal: Viton (FKM)

2 Antenna adapter 316L / 1.4404

3 housing adapter 316L / 1.4404

4 Housing seal EPDM

54 Endress+Hauser
Micropilot FMR62

No. Component part Material

5 Process connection 316L / 1.4404 , PTFE cladded

6 DIN11851 slotted nut 304L / 1.4307

Endress+Hauser 55
Micropilot FMR62

Materials: Weather
protection cover 1

2
3

7 4
5
6
A0015473

No Part: Material

1 Protection cover: 316L (1.4404)

2 Molded rubber part (4x): EPDM

3 Clamping screw: 316L (1.4404) + carbon fibre

4 Bracket: 316L (1.4404)

5 • Cheese head screw: A4-70


• Nut: A4
• Spring washer: A4

6 Ground terminal
• Screw: A4
• Spring washer: A4
• Clamp: 316L (1.4404)
• Holder: 316L (1.4404)

7 • Washer: A4
• Cheese head screw: A4-70

56 Endress+Hauser
Micropilot FMR62

Operability
Operating concept Operator-oriented menu structure for user-specific tasks
• Commissioning
• Operation
• Diagnostics
• Expert level
Operating languages
• English
• Deutsch
• Français
• Español
• Italiano
• Nederlands
• Portuguesa
• Polski
• русский язык (Russian)
• Svenska
• Türkçe
• 中文 (Chinese)
• 日本語 (Japanese)
• 한국어 (Korean)
• Bahasa Indonesia
• tiếng Việt (Vietnamese)
• čeština (Czech)
Feature 500 of the product structure determines which of these languages is preset on delivery.

Quick and save commissioning


• Interactive wizard with graphical interface for easy commissioning via FieldCare/DeviceCare
• Menu guidance with brief explanations of the individual parameter functions
• Standardized operation at the device and in the operating tools
Integrated data storage device (HistoROM)
• Enables transfer of configuration when changing electronic modules
• Records up to 100 event messages in the device
• Records up to 1000 measured values in the device
• Saves the signal curve on commissioning which can later be used as a reference.
Efficient diagnostics increase measurement reliability
• Remedy information is integrated in plain text
• Diverse simulation options and line recorder functions

Endress+Hauser 57
Micropilot FMR62

Local operation Operation Pushbuttons Touch Control


with

Order code for Option C "SD02" Option E "SD03"


"Display;
Operation"

A0032219 A0032221

Display 4-line display 4-line display


elements white background lighting; switches to red in
event of device error

Format for displaying measured variables and status variables can be individually configured

Permitted ambient temperature for the display: –20 to +70 °C (–4 to +158 °F)
The readability of the display may be impaired at temperatures outside the temperature
range.

Operating local operation with 3 push buttons (, , external operation via touch control; 3 optical
elements ) keys: , , 

Operating elements also accessible in various hazardous areas

Additional Data backup function


functionality The device configuration can be saved in the display module.

Data comparison function


The device configuration saved in the display module can be compared to the current device
configuration.

Data transfer function


The transmitter configuration can be transmitted to another device using the display module.

Operation with remote


1 2
display and operating
module FHX50

A0032215

 23 FHX50 operating options


1 Housing of the remote display and operating module FHX50
2 Display and operating module SD02, push buttons; cover must be removed
3 Display and operating module SD03, optical keys; can be operated through the glass of the cover

58 Endress+Hauser
Micropilot FMR62

Remote operation Via HART protocol

2 3 6 8

1 4 5 7
A0028746

 24 Options for remote operation via HART protocol


1 PLC (programmable logic controller)
2 Transmitter power supply unit, e.g. RN221N (with communication resistor)
3 Connection for Commubox FXA191, FXA195 and Field Communicator 375, 475
4 Field Communicator 475
5 Computer with operating tool (e.g. DeviceCare/FieldCare , AMS Device Manager, SIMATIC PDM)
6 Commubox FXA191 (RS232) or FXA195 (USB)
7 Field Xpert SFX350/SFX370
8 VIATOR Bluetooth modem with connecting cable
9 Transmitter

Via service interface (CDI)

1
A0032466

1 Service interface (CDI) of the measuring device (= Endress+Hauser Common Data Interface)
2 Commubox FXA291
3 Computer with DeviceCare/FieldCare operating tool

Endress+Hauser 59
Micropilot FMR62

SupplyCare inventory SupplyCare is a web-based operating program for coordinating the flow of material and information
management software along the supply chain. SupplyCare provides a comprehensive overview of the levels of
geographically distributed tanks and silos, for instance, providing complete transparency over the
current inventory situation, regardless of time and location.
Based on the measuring and transmission technology installed onsite, the current inventory data are
collected and sent to SupplyCare. Critical levels are clearly indicated and calculated forecasts provide
additional security for material requirements planning.
The main functions of SupplyCare:
Inventory visualization
SupplyCare determines the inventory levels in tanks and silos at regular intervals. It displays current
and historical inventory data and calculated forecasts of future demand. The overview page can be
configured to suit the user's preferences.
Master data management
With SupplyCare you can create and manage the master data for locations, companies, tanks,
products and users, as well as user authorization.
Report Configurator
The Report Configurator can be used to create personalized reports quickly and easily. The reports
can be saved in a variety of formats, such as Excel, PDF, CSV and XML. The reports can be
transmitted in many ways, such as by http, ftp or e-mail.
Event management
Events, such as when levels drop below the safety stock level or plan points, are indicated by the
software. In addition, SupplyCare can also notify pre-defined users by e-mail.
Alarms
If technical problems occur, e.g. connection issues, alarms are triggered and alarm e-mails are sent to
the System Administrator and the Local System Administrator.
Delivery planning
The integrated delivery planning function automatically generates an order proposal if a pre-set
minimum inventory level is undershot. Scheduled deliveries and disposals are monitored
continuously by SupplyCare. SupplyCare notifies the user if scheduled deliveries and disposals are not
going to be met as planned.
Analysis
In the Analysis module, the most important indicators for the inflow and outflow of the individual
tanks are calculated and displayed as data and charts. Key indicators of material management are
automatically calculated and form the basis for optimizing the delivery and storage process.
Geographical visualization
All the tanks and the tank inventories are represented graphically on a map (based on Google Maps).
The tanks and inventory situations can be filtered by tank group, product, supplier or location.
Multi-language support
The multi-language user interface supports 9 languages, thereby enabling global collaboration on a
single platform. The language and settings are recognized automatically using the browser settings.

SupplyCare Enterprise
SupplyCare Enterprise runs by default as a service under Microsoft Windows on an application server
in an Apache Tomcat environment. The operators and administrators operate the application via a
Web browser from their workstations.

60 Endress+Hauser
Micropilot FMR62

2
3

10
5 7 8
9

.
A0034288

 25 Example of inventory management platform with SupplyCare Enterprise SCE30B


1 SupplyCare Enterprise (via Web browser)
2 SupplyCare Enterprise installation
3 SupplyCare Enterprise on mobile devices (via Web browser)
4 Ethernet/WLAN/UMTS
5 Fieldgate FXA42
6 Power supply 24 V DC
7 Modbus TCP via Ethernet as server/client
8 Converter from Modbus to HART Multidrop
9 HART Multidrop
10 4 x 4 to 20 mA analog input (2-wire/4-wire)

Endress+Hauser 61
Micropilot FMR62

Cloud-based application: SupplyCare Hosting


SupplyCare Hosting is offered as a hosting service (software as a service). Here, the software is
installed within the Endress+Hauser IT infrastructure and made available to the user in the Endress
+Hauser portal.

1
3
WWW

4
10
5 7 8
9

.
A0034289

 26 Example of inventory management platform with SupplyCare Hosting SCH30


1 SupplyCare Hosting installation in Endress+Hauser data center
2 PC workstation with Internet connection
3 Warehouse locations with Internet connection via 2G/3G with FXA42 or FXA30
4 Warehouse locations with Internet connection with FXA42
5 Fieldgate FXA42
6 Power supply 24 V DC
7 Modbus TCP via Ethernet as server/client
8 Converter from Modbus to HART Multidrop
9 HART Multidrop
10 4 x 4 to 20 mA analog input (2-wire/4-wire)

With SupplyCare Hosting, users do not need to make the initial software purchase or install and run
the IT infrastructure needed. Endress+Hauser constantly update SupplyCare Hosting and enhance
the capability of the software in conjunction with the customer. The hosted version of SupplyCare is
thus always up-to-date and can be customized to meet different customer requirements. Other
services are also offered in addition to the IT infrastructure and the software that is installed in a
secure, redundant Endress+Hauser data center. These services include defined availability of the
global Endress+Hauser Service and Support Organization and defined response times in a service
event.

62 Endress+Hauser
Micropilot FMR62

Certificates and approvals


CE mark The measuring system meets the legal requirements of the applicable EC guidelines. These are listed
in the corresponding EC Declaration of Conformity together with the standards applied.
Endress+Hauser confirms successful testing of the device by affixing to it the CE mark.

RoHS The measuring system complies with the substance restrictions of the Restriction on Hazardous
Substances Directive 2011/65/EU (RoHS 2).

RCM-Tick marking The supplied product or measuring system meets the ACMA (Australian Communications and Media
Authority) requirements for network integrity, interoperability, performance characteristics as well
as health and safety regulations. Here, especially the regulatory arrangements for electromagnetic
compatibility are met. The products are labelled with the RCM- Tick marking on the name plate.

A0029561

Ex approval • ATEX
• IECEx
• CSA
• FM
• NEPSI
• KC
• INMETRO
• TIIS 5)
• EAC
Additional safety instructions must be followed for use in hazardous areas. Please refer to the
separate "Safety Instructions" (XA) document included in the delivery. Reference to the applicable XA
can be found on the nameplate.
For details on the available certificates and associated XAs: →  81

Dual seal according to The devices have been designed according to ANSI/ISA 12.27.01 as dual seal devices, allowing the
ANSI/ISA 12.27.01 user to waive the use and save the cost of installing external secondary process seals in the conduit
as required by the process sealing sections of ANSI/NFPA 70 (NEC) and CSA 22.1 (CEC) These
instruments comply with the North-American installation practice and provide a very safe and cost-
saving installation for pressurized applications with hazardous fluids.
Further information can be found in the Safety Instructions (XA) of the relevant devices.

Functional safety Use for level monitoring (MIN, MAX, range) up to SIL 3 (homogeneous or diverse redundancy),
independently evaluated by TÜV Rheinland in accordance with IEC 61508, refer to the "Functional
Safety Manual" for information.

WHG WHG approval: No. requested

Hygienic compatibility FMR62 with flange cladding made of PTFE complies with FDA 21 CFR 177.1550 and
USP <88> Class VI.

5) in preparation

Endress+Hauser 63
Micropilot FMR62

3A and EHEDG approval for versions with Tri-Clamp and DIN11851 process connections. 6)
To avoid any risk of contamination, install the device according to the “Hygienic Equipment
Design Criteria (HDC)” which was published by the Subgroup "Design Principles" of the EHEDG
on April 8 2004.
Suitable fittings and seals must be used to ensure hygiene-compliant design according to the
specifications of 3-A SSI and EHEDG.
The gap-free connections can be cleaned of all residue using the usual cleaning methods within
this industry.
The 316L housing (GT18), option B in order feature 40, is not suitable for use in applications
which require a 3A approval.

NACE MR 0175 / ISO 15156 • The wetted, metal materials comply with the requirements of NACE MR 0175 / ISO 15156.
• Declaration of Conformity: see the product structure, feature 580, version JB

NACE MR 0103 • The wetted, metal materials comply with the requirements of NACE MR 0103.
• The Declaration of Conformity is based on NACE MR 0175.
The hardness and intergranular corrosion have been tested, and heat treatment (solution
annealed) has been performed. The materials used therefore meet the requirements of
NACE MR 0103.
• Declaration of Conformity: see the product structure, feature 580, version JE.

Pressure equipment with Pressure instruments with a flange and threaded boss that do not have a pressurized housing do not
allowable pressure fall within the scope of the Pressure Equipment Directive, irrespective of the maximum allowable
≤ 200 bar (2 900 psi) pressure.

Reasons:
According to Article 2, point 5 of EU Directive 2014/68/EU, pressure accessories are defined as
"devices with an operational function and having pressure-bearing housings".
If a pressure instrument does not have a pressure-bearing housing (no identifiable pressure chamber
of its own), there is no pressure accessory present within the meaning of the Directive.

Marine approval Device Marine approval 1)

LF: LG: LH: LJ:


ABS marine LR marine approval BV marine approval DNV GL marine
approval approval

FMR62    

1) See order code for 590 "Additional approval"

Radio standard The devices FMR62 with antenna 40 mm / 2" integrated PEEK, comply with the Level Probing Radar
EN 302729-1/2 (LPR) radio standard EN 302729-1/2. The devices FMR62 with antenna 40 mm / 2" integrated
PEEK, are approved for unrestricted use inside and outside closed containers in countries of the EU
and the EFTA . that have already implemented this standard.
The following countries are those that have currently implemented the directive:
Belgium, Bulgaria, Germany, Denmark, Estonia, France, Greece, UK, Ireland, Iceland, Italy,
Liechtenstein, Lithuania, Latvia, Malta, The Netherlands, Norway, Austria, Poland, Portugal,
Romania, Sweden, Switzerland, Slovakia, Spain, Czech Republic and Cyprus.
Implementation is still underway in all of the countries not listed.

Please note the following for operation of the devices outside of closed vessels:
1. Installation must be carried out by properly trained, expert staff.
2. The device antenna must be installed in a fixed location pointing vertically downwards.

6) EHEDG pending

64 Endress+Hauser
Micropilot FMR62

3. The installation site must be located at a distance of 4 km from the astronomy stations listed
below or otherwise approval must be provided by the relevant authority. If the device is
installed at a distance of 4 to 40 km from one of the listed stations, it must not be installed at a
height of more than 15 m (49 ft) above the ground.

Astronomy stations
Country Name of the station Latitude Longitude

Germany Effelsberg 50°31'32" North 06°53'00" East

Finland Metsähovi 60°13'04" North 24°23'37" East

Tuorla 60°24'56" North 24°26'31" East

France Plateau de Bure 44°38'01" North 05°54'26" East

Floirac 44°50'10" North 00°31'37" West

Great Britain Cambridge 52°09'59" North 00°02'20" East

Damhall 53°09'22" North 02°32'03" West

Jodrell Bank 53°14'10" North 02°18'26" West

Knockin 52°47'24" North 02°59'45" West

Pickmere 53°17'18" North 02°26'38" West

Italy Medicina 44°31'14" North 11°38'49" East

Noto 36°52'34" North 14°59'21" East

Sardinia 39°29'50" North 09°14'40" East

Poland Fort Skala Krakow 50°03'18" North 19°49'36" East

Russia Dmitrov 56°26'00" North 37°27'00" East

Kalyazin 57°13'22" North 37°54'01" East

Pushchino 54°49'00" North 37°40'00" East

Zelenchukskaya 43°49'53" North 41°35'32" East

Sweden Onsala 57°23'45" North 11°55'35" East

Switzerland Bleien 47°20'26" North 08°06'44" East

Spain Yebes 40°31'27" North 03°05'22" West

Robledo 40°25'38" North 04°14'57" West

Hungary Penc 47°47'22" North 19°16'53" East

As a general rule, the requirements outlined in EN 302729-1/2 must be observed.

Radio standard The devices comply with the Tanks Level Probing Radar (TLPR) radio standard EN 302372-1/2 and
EN 302372-1/2 are approved for use in closed containers. For installation, points a to f in Annex B of EN 302372-1
must be taken into consideration.

FCC This device complies with Part 15 of the FCC rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
[Any] changes or modifications not expressly approved by the party responsible for compliance could
void the user's authority to operate the equipment.
The devices are compliant with the FCC Code of Federal Regulations, CFR 47, Part 15, Sections
15.205, 15.207, 15.209.
In addition, the devices are compliant with Section 15.256 . For these LPR (Level Probe Radar)
applications the devices must be professionally installed in a downward operating position. In
addition, the devices are not allowed to be mounted in a zone of 4 km around RAS stations and
within a radius of 40 km around RAS stations the maxium operation height of devices is 15 m (49 ft)
above ground.

Endress+Hauser 65
Micropilot FMR62

Industry Canada Canada CNR-Gen Section 7.1.3


This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to
the following two conditions: (1) This device may not interference, and (2) this device must accept
any interference, including interference that may cause undesired operation of the device.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts
de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas
produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique
subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.
[Any] changes or modifications not expressly approved by the party responsible for compliance could
void the user's authority to operate the equipment.
• The installation of the LPR/TLPR device shall be done by trained installers, in strict compliance
with the manufacturer’s instructions.
• The use of this device is on a “no-interference, no-protection” basis. That is, the user shall accept
operations of high-powered radar in the same frequency band which may interfere with or
damage this device. However, devices found to interfere with primary licensing operations will be
required to be removed at the user’s expense.
• This device shall be installed and operated in a completely enclosed container to prevent RF
emissions, which can otherwise interfere with aeronautical navigation.
• The installer/user of this device shall ensure that it is at least 10 km from the Dominion
Astrophysical Radio Observatory (DRAO) near Penticton, British Columbia. The coordinates of the
DRAO are latitude 49°19ʹ15ʹʹ N and longitude 119°37ʹ12ʹʹ W. For devices not meeting this 10 km
separation (e.g., those in the Okanagan Valley, British Columbia,) the installer/user must
coordinate with, and obtain the written concurrence of, the Director of the DRAO before the
equipment can be installed or operated. The Director of the DRAO may be contacted at
250-497-2300 (tel.) or 250-497-2355 (fax). (Alternatively, the Manager, Regulatory Standards
Industry Canada, may be contacted.)
The Model FMR62F is a submodel of the FMR62. "F" indicates the unique option GF of the
feature 070 ("Antenna") that fullfills the requirements for use as LPR (Level Probe Radar).

CRN approval Some device versions have CRN approval. Devices are CRN approved if the following two conditions
are met:
• The device has a CSA approval (product structure: feature 010 "Approval")
• The device has a CRN-approved process connection as per the following table:

Feature 100 in the product structure Process connection

AFK NPS 2" Cl.150, PTFE >316/316L

AGK NPS 3" Cl.150, PTFE >316/316L

AHK NPS 4" Cl.150, PTFE >316/316L

AJK NPS 6" Cl.150, PTFE >316/316L

MRK DIN11851 DN50 PN25 slotted nut, PTFE>316L

MTK DIN11851 DN80 PN25 slotted nut, PTFE>316L

RGJ Thread ANSI MNPT1-1/2, 316L

TDK Tri-Clamp ISO2852 DN40-51 (2"), PTFE>316L

TFK Tri-Clamp ISO2852 DN70-76.1 (3"), PTFE>316L 1)

THK Tri-Clamp ISO2852 DN101.6 (4"), PTFE>316L 1)

1) The CRN certificate applies in a limited pressure range; see the following table.

• Process connections that do not have CRN approval are not listed in this table.
• Please refer to the product structure to discover which process connections are available for a
specific device type.
• CRN-approved devices bear the registration number (tbd.) on the nameplate.
An additional pressure restriction applies for the device versions listed in the table below if they
are CRN-approved. The pressure range indicated in the "Process" section →  39 continues to
apply for device versions not listed in the table below (in preparation).

66 Endress+Hauser
Micropilot FMR62

Test, certificate Feature 580 "Test, Description


certificate"

JA 3.1 Material certificate, wetted metal parts, EN10204-3.1 inspection certificate

JB Declaration of Conformity NACE MR0175, wetted metal parts

JD 3.1 Material certificate, pressurized parts, EN10204-3.1 inspection certificate

JE Declaration of Conformity NACE MR0103, wetted metal parts

JF Declaration of Conformity AD2000, wetted metal parts:


Material conformity for all metal wetted/pressurized parts according to AD2000 (data
sheets W2, W9, W10)

JG Declaration of Conformity AD2000, pressurized metal parts

JJ Declaration of Conformity FDA

JK Declaration of Conformity, TSE Certificate of Suitability

JL Declaration of Conformity EC1935/2004

KE Pressure test, internal procedure, inspection certificate

KI PMI test (XRF), internal procedure, inspection certificate

KV Declaration of Conformity ASME B31.3:


The construction, the material used, the pressure and temperature ranges and the
labeling of the devices meet the requirements of ASME B31.3

Test reports, declarations and inspection certificates are available in electronic format in the
W@M Device Viewer:
Enter the serial number from nameplate (www.endress.com/deviceviewer)
This concerns the options for the following order codes:
• 550 "Calibration"
• 580 "Test, certificate"
• 590 "Additional approval", option LW: "CoC-ASME BPE"

Hard-copy product Hard-copy versions of the test reports, declarations and inspection certificates can also be order via
documentation order code 570 "Service", option I7 "Hard-copy product documentation". The documents are then
supplied with the product.

Endress+Hauser 67
Micropilot FMR62

Other standards and • EN 60529


guidelines Degrees of protection provided by enclosures (IP code)
• EN 61010-1
Safety Requirements for Electrical Equipment for Measurement, Control and Laboratory Use
• IEC/EN 61326
"Emission in accordance with Class A requirements". Electromagnetic compatibility (EMC
requirements).
• NAMUR NE 21
Electromagnetic compatibility (EMC) of industrial process and laboratory control equipment
• NAMUR NE 43
Standardization of the signal level for the breakdown information of digital transmitters with
analog output signal.
• NAMUR NE 53
Software of field devices and signal-processing devices with digital electronics
• NAMUR NE 107
Status classification as per NE107
• NAMUR NE 131
Requirements for field devices for standard applications.
• IEC61508
Functional safety of safety-related electric/electronic/programmable electronic systems

68 Endress+Hauser
Micropilot FMR62

Ordering information
Ordering information Detailed ordering information is available from the following sources:
• In the Product Configurator on the Endress+Hauser website: www.endress.com -> Click "Corporate"
-> Select your country -> Click "Products" -> Select the product using the filters and search field ->
Open product page -> The "Configure" button to the right of the product image opens the Product
Configurator.
• From your Endress+Hauser Sales Center: www.addresses.endress.com
Product Configurator - the tool for individual product configuration
• Up-to-the-minute configuration data
• Depending on the device: Direct input of measuring point-specific information such as
measuring range or operating language
• Automatic verification of exclusion criteria
• Automatic creation of the order code and its breakdown in PDF or Excel output format
• Ability to order directly in the Endress+Hauser Online Shop

Endress+Hauser 69
Micropilot FMR62

3-point linearity protocol The following points must be considered if option F3 (3-point linearity protocol) was selected in
feature 550 ("Calibration").
The 3 points of the linearity protocol are defined as follows:

A
1

6000 (236)

500 (19.7)
2

A0032285

 27 Points of the 3-point linearity protocol; engineering unit: mm (in)


A Distance from the reference point R to the first measuring point
R Reference point of measurement
1 First measuring point
2 Second measuring point (in the middle between the first and third measuring point)
3 Third measuring point

Measuring point Position

1st measuring point • At a distance A from the reference point


• A = length of antenna + 500 mm (19.7 in)
• Minimum distance: Amin = 1 000 mm (39.4 in)

2nd measuring point In the middle between the 1st and 3rd measuring point

3rd measuring point 6 000 mm (236 in) below the reference point R

The position of the measuring points can vary by ±1 cm (±0.04 in).

The linearity check is performed under reference operating conditions.

70 Endress+Hauser
Micropilot FMR62

5-point linearity protocol The following points must be considered if option F4 (5-point linearity protocol) was selected in
feature 550 ("Calibration").
The 5 points of the linearity protocol are evenly distributed over the measuring range (0% - 100%).
Empty calibration (E) and Full calibration (F) must be specified in order to define the measuring
range 7).
The following restrictions must be considered when selecting E and F:

A
E
F
A0032286

Minimum distance between reference point R and Minimum span Maximum value for "Empty
100% mark calibration"

A ≥ length of antenna + 200 mm (8 in) F ≥400 mm (16 in) E ≤24 m (79 ft)
Minimum value: 400 mm (16 in)

The linearity check is performed under reference operating conditions.

The selected values for Empty calibration and Full calibration are only used to create the
linearity protocol. Afterwards, the values are reset to the default values specific for the
antenna. If values other than the default values are required, they must be ordered as a
customized parameterization →  72.

7) If (E) and (F) are not specified, antenna-dependent default values will be used instead.

Endress+Hauser 71
Micropilot FMR62

Customer-specific If the option IJ: "Customized parameterization HART", IK "Customized parameterization PA" or IL
configuration "Customized parameterization FF" has been selected in feature 570 "Service", presettings that differ
from the default settings can be selected for the following parameters:

Parameters Communication Picklist / range of values


protocol

Setup → Unit of length • HART • in


• PA • ft
• FF • mm
• m

Setup → Empty calibration • HART max. 70 m (230 ft)


• PA
• FF

Setup → Full calibration • HART max. <70 m (230 ft)


• PA
• FF

Setup → Extended setup → Curr. output 1 or 2 → Damping HART 0 to 999.9 s

Setup → Extended setup → Curr. output 1 or 2 → Failure HART • Min


mode • Max
• Last valid value

Expert → Comm. → HART config. → Burst mode HART • Off


• On

Tagging (TAG) Ordering feature 895: Marking

Option Z1: Tagging (TAG), see additional spec.

Position of the measuring To be selected in the additional specifications:


point marking • Tag plate Stainless Steel
• Self-adhesive paper label
• Supplied label/plate
• RFID TAG
• RFID TAG + Tag plate Stainless Steel
• RFID TAG + Self-adhesive paper label
• RFID TAG + Supplied label/plate

Definition of the measuring To be defined in the additional specifications:


point designation 3 lines containing up to 18 characters each
The measuring point designation appears on the selected label and/or the
RFID TAG.

Designation in the Electronic The first 32 characters of the measuring point designation
Name Plate (ENP)

Designation on the display The first 12 characters of the measuring point designation
module

Services The following services can be selected via the product structure in the Product Configurator 8):
• PWIS-free (PWIS = paint-wetting impairment substances)
• Customized parameterization HART →  72
• Customized parameterization PA →  72
• Customized parameterization FF →  72
• W/o tooling DVD (FieldCare)
• Hard-copy product documentation

8) Feature 570 in the product structure

72 Endress+Hauser
Micropilot FMR62

Application Packages
Heartbeat Diagnostics Availability
Available in all device versions.

Function
• Continuous self-monitoring of the device.
• Diagnostic messages output to
– the local display.
– an asset management system (e.g. FieldCare/DeviceCare).
– an automation system (e.g. PLC).

Advantages
• Device condition information is available immediately and processed in time.
• The status signals are classified in accordance with VDI/VDE 2650 and NAMUR recommendation
NE 107 and contain information about the cause of the error and remedial action.

Detailed description
See Operating Instructions of the device (→  81); chapter "Diagnostics and trouble shooting"

Endress+Hauser 73
Micropilot FMR62

Heartbeat Verification Availability


Available for the following options of feature 540 "Application Package":
• EH: Heartbeat Verification + Monitoring
• EJ:   Heartbeat Verification

Device functionality checked on demand


• Verification of the correct functioning of the measuring device within specifications.
• The verification result provides information about the condition of the device: Passed or Failed.
• The results are documented in a verification report.
• The automatically generated report supports the obligation to demonstrate compliance with
internal and external regulations, laws and standards.
• Verification is possible without interrupting the process.

Advantages
• No onsite presence is required to use the function.
• The DTM 9) triggers verification in the device and interprets the results. No specific knowledge is
required on the part of the user.
• The verification report can be used to prove quality measures to a third party.
• Heartbeat Verification can replace other maintenance tasks (e.g. periodic check) or extend the
test intervals.

SIL/WHG-locked devices 10)

• The Heartbeat Verification module contains a wizard for the proof test which must be performed
at appropriate intervals for the following applications:
– SIL (IEC61508/IEC61511)
– WHG (German Water Resources Act)
• To perform a proof test, the device must be locked (SIL/WHG locking).
• The wizard can be used via FieldCare, DeviceCare or a DTM-based process control system.
In the case of SIL-locked and WHG-locked devices, it is not possible to perform verification
without additional measures (e.g. by-passing of the output current) because the output current
must be simulated (Increased safety mode) or the level must be approached manually (Expert
mode) during subsequent re-locking (SIL/WHG locking).

Detailed description
SD01870F

9) DTM: Device Type Manager; controls device operation via DeviceCare, FieldCare or a DTM-based process control system.
10) Only relevant for devices with SIL or WHG approval: order code 590 ("Additional approval"), option LA ("SIL") or LC ("WHG").

74 Endress+Hauser
Micropilot FMR62

Heartbeat Monitoring Availability


Available for the following options of feature 540 "Application Package":
EH: Heartbeat Verification + Monitoring

Function
• In addition to the verification parameters, the corresponding parameter values are also logged.
• Existing measured variables, such as the echo amplitude, are used in the Foam detection and
Build-up detection wizards.
The Foam detection and Build-up detection wizards cannot be used together.

"Foam detection" wizard


• The Heartbeat Monitoring module contains the Foam detection wizard.
• This wizard is used to configure automatic foam detection, which detects foam on the product
surface on the basis of the reduced signal amplitude. Foam detection can be linked to a switch
output in order to control a sprinkler system, for example, which dissolves the foam.
• This wizard can be used via FieldCare, DeviceCare or a DTM-based process control system.

"Build-up detection" wizard


• The Heartbeat Monitoring module contains the Build-up detection wizard.
• The wizard is used to configure automatic buildup detection, which detects the buildup of deposits
on the antenna on the basis of the increased area of the coupling signal. Buildup detection can be
linked to a switch output in order to control a compressed air system, for example, to clean the
antenna.
• This wizard can be used via FieldCare, DeviceCare or a DTM-based process control system.

Advantages
• Early detection of changes (trends) to ensure plant availability and product quality.
• Use of information for the proactive planning of measures (e.g. cleaning/maintenance).
• Identification of undesirable process conditions as the basis to optimizing the facility and the
processes.
• Automated control of measures to remove foam or buildup.

Detailed description
SD01870F

Endress+Hauser 75
Micropilot FMR62

Accessories
Device-specific accessories Weather protection cover

Accessory Description

Weather protection cover

222 (8.74)
A0015466

300 (11.8) 275 (10.8)


255.1 (10) 164 (6.46) 54
(2
.13
)
55
5)
(1.

4)
38

35°
65°
(6.1
156

A0015472

 28 Weather protection cover; Dimensions: mm (in)

 Enclosed",
The weather protection cover can be ordered together with the device (product structure, feature 620 "Accessory
option PB "Weather Protection Cover").
Alternatively, it can be separately ordered as an accessory; order code 71162242.

76 Endress+Hauser
Micropilot FMR62

Remote display FHX50

Accessories Description

Remote display FHX50

2.
1.
4.
3.

A0019128

• Material:
– Plastic PBT
– 316L/1.4404
– Aluminum
• Degree of protection: IP68 / NEMA 6P and IP66 / NEMA 4x
• Suitable for display modules:
– SD02 (push buttons)
– SD03 (touch control)
• Connecting cable:
– Cable supplied with device up to 30 m (98 ft)
– Standard cable supplied by customer up to 60 m (196 ft)
• Ambient temperature range: –40 to 80 °C (–40 to 176 °F)

 • IfL ortheM).remote display should be used, order the device version "Prepared for display FHX50" (feature 030, version
For the FHX50, you must select option A: "Prepared for display FHX50" under feature 050 "Measuring
device version".
• If the device version "Prepared for display FHX50" was not originally ordered and a FHX50 display is to be
retrofitted, you must select version B "Not prepared for display FHX50" under feature 050: "Measuring device
version" when ordering the FHX50. In this case, a retrofit kit for the device is supplied with the FHX50. The kit
can be used to prepare the device so that the FHX50 can be used.

 FHX50
Use of the FHX50 may be restricted for transmitters with an approval. A device can only be retrofitted with the
if the option L or M ("Prepared for FHX50") is listed under Basic specifications, item 4 "Display, operation" in
the Safety Instructions (XA) for the device.
Also pay attention to the Safety Instructions (XA) of the FHX50.

 Retrofitting is not possible on transmitters with:


• An approval for use in areas with flammable dust (dust ignition-proof approval)
• Ex nA type of protection

 For details, see document SD01007F.

Endress+Hauser 77
Micropilot FMR62

Overvoltage protection

Accessory Description

Overvoltage protection for


2-wire-devices
OVP10 (1 channel)
OVP20 (2 channel)

A0021734

Technical data
• Resistance per channel: 2 * 0.5 Ωmax
• Threshold DC voltage: 400 to 700 V
• Threshold impulse voltage: < 800 V
• Capacitance at 1 MHz: < 1.5 pF
• Nominal arrest impulse voltage (8/20 μs): 10 kA
• Suited for wire cross-sections: 0.2 to 2.5 mm2 (24 to 14 AWG)

 Ordering with device


The overvoltage protection module is preferably ordered with the device. See product structure, feature 610
"Accessory mounted", option NA "Overvoltage protection". Separate ordering of the module is only necessary if a
device is to retrofitted with the overvoltage protection.

 Order code for retrofitting


• For 1-channel devices (feature 020, option A)
OVP10: 71128617
• For 2-channel devices (feature 020, option B, C, E or G)
OVP20 : 71128619
Hosuing lid for retrofitting
In order to keep the necessary safety distances, the housing lid needs to be replaced if the device is retrofitted with
the overvoltage protection. Depending on the housing type, the order code of the suitable lid is as follows:
• GT18 housing: Lid 71185516
• GT19 housing: Lid 71185518
• GT20 housing: Lid 71185516

 Restrictions for retrofitting


Depending on the approval of the transmitter the usage of the OVP module may be restricted. A device may only be
retrofitted with an OVP module if the option NA (overvoltage protection) is quoted unter Optional Specifications in
the Safety Instructions (XA) pertaining to the device.

 For details refer to SD01090F.

Gas-tight feedthrough

Accessories Description

Gas-tight feedthrough Chemically inert glass feedthrough; prevents gases from entering the electronics housing
To order with the device: product structure, feature 610 "Accessory mounted", option NC "Gas-tight feedthrough"

78 Endress+Hauser
Micropilot FMR62

Communication-specific Accessory Description


accessories
Commubox FXA195 For intrinsically safe HART communication with FieldCare via the USB interface.
HART
 For details refer to Technical Information TI00404F

Accessory Description

Commubox FXA291 Connects Endress+Hauser field devices with CDI interface (= Endress+Hauser
Common Data Interface) to the USB interface of a computer.
Order code: 51516983

 For details refer to Technical Information TI00405C

Accessory Description

HART Loop Converter Evaluates the dynamic HART variables and converts them to analog current signals
HMX50 or limit values.
Order code: 71063562

 For details refer to Technical Information TI00429F and Operating


Instructions BA00371F

Accessory Description

WirelessHART Adapter Connects field devices to a WirelessHART network.


SWA70 The WirelessHART adapter can be mounted directly at a HART device and is easly
integrated into an existing HART network. It ensures safe data transmission and
can be operated in parallel with other wireless networks.

 For details refer to Operating Instructions BA00061S

Accessories Description

Connect Sensor Fully integrated, battery-powered gateway for simple applications with SupplyCare Hosting.
FXA30/FXA30B Up to 4 field devices with 4 to 20 mA communication (FXA30/FXA30B), serial Modbus
(FXA30B) or HART (FXA30B) can be connected. With its robust design and ability to run for
years on the battery, it is ideal for remote monitoring in isolated locations. Version with LTE
(USA, Canada and Mexico only) or 3G mobile transmission for worldwide communication.

 BA01710S.
For details, see "Technical Information" TI01356S and Operating Instructions

Accessories Description

Fieldgate Fieldgates enable communication between connected 4 to 20 mA, Modbus RS485 and
FXA42 Modbus TCP devices and SupplyCare Hosting or SupplyCare Enterprise. The signals are
transmitted either via Ethernet TCP/IP, WLAN or mobile communications (UMTS). Advanced
automation capabilities are available, such as an integrated Web-PLC, OpenVPN and other
functions.

 BA01778S.
For details, see "Technical Information" TI01297S and Operating Instructions

Accessories Description

SupplyCare Inventory management software that visualizes levels, volumes, masses, temperatures,
Enterprise pressures, densities or other tank parameters. The parameters are recorded and transmitted
SCE30B by means of gateways of the type Fieldgate FXA42.
This Web-based software is installed on a local server and can also be visualized and
operated with mobile terminals such as a smartphone or tablet.

 BA00055S
For details, see "Technical Information" TI01228S and Operating Instructions

Endress+Hauser 79
Micropilot FMR62

Accessories Description

SupplyCare Inventory management software that visualizes levels, volumes, masses, temperatures,
Hosting SCH30 pressures, densities or other tank parameters. The parameters are recorded and transmitted
by means of gateways of the type Fieldgate FXA42, FXA30 and FXA30B.
SupplyCare Hosting is offered as a hosting service (Software as a Service, SaaS). In the
Endress+Hauser portal, the user is provided with the data over the Internet.

 BA00050S.
For details, see "Technical Information" TI01229S and Operating Instructions

Accessory Description

Field Xpert SFX350 Field Xpert SFX350 is a mobile computer for commissioning and maintenance. It
enables efficient device configuration and diagnostics for HART and FOUNDATION
fieldbus devices in the non-Ex area.

 For details, see Operating Instructions BA01202S

Accessory Description

Field Xpert SFX370 Field Xpert SFX370 is a mobile computer for commissioning and maintenance. It
enables efficient device configuration and diagnostics for HART and FOUNDATION
fieldbus devices in the non-Ex area and the Ex area.

 For details, see Operating Instructions BA01202S


Service-specific accessories Accessory Description

DeviceCare SFE100 Configuration tool for HART, PROFIBUS and FOUNDATION Fieldbus devices

 Technical Information TI01134S


 • DeviceCare is available for download at
www.software-products.endress.com. The download requires a
registration in the Endress+Hauser software portal.
• Alternatively, a DeviceCare DVD can be ordered with the device. Product
structure: Feature 570 "Service", Option IV "Tooling DVD (DeviceCare
Setup)".

FieldCare SFE500 Endress+Hauser's FDT-based Plant Asset Management tool.


Helps to configure and maintain all field devices of your plant. By supplying status
information it also supports the diagnosis of the devices.

 Technical Information TI00028S


System components Accessory Description

Graphic Data Manager The graphic data manager Memograph M provides information on all the relevant
Memograph M process variables. Measured values are recorded correctly, limit values are
monitored and measuring points analyzed. The data are stored in the 256 MB
internal memory and also on an SD card or USB stick.

 For details refer to Technical Information TI00133R and Operating


Instructions BA00247R

RN221N Active barrier with power supply for safe separation of 4 to 20 mA current circuits.
Provides bi-directional HART transmission.

 For details refer to Technical Information TI00073R and Operating


Instructions BA00202R

RNS221 Transmitter supply for 2-wire sensors or transmitters exclusively for non-Ex areas.
Provides bi-directional communication using the HART communication sockets.

 For details refer to Technical Information TI00081R and Operating


Instructions KA00110R

80 Endress+Hauser
Micropilot FMR62

Supplementary documentation
For an overview of the scope of the associated Technical Documentation, refer to the following:
• The W@M Device Viewer: enter the serial number from the nameplate
(www.endress.com/deviceviewer)
• The Endress+Hauser Operations App: Enter the serial number from the nameplate or scan the
2-D matrix code (QR code) on the nameplate.
The following document types are available:
In the Download Area of the Endress+Hauser Internet site: www.endress.com → Downloads

Standard documentation Micropilot FMR62

Correlation of documentations to the device:


Device Power supply, Communication Document type Document code
output

FMR62 A, B, C, K, L HART Operating Instructions BA01619F

Brief Operating Instructions KA01252F

Description of device GP01101F


parameters

Safety Instructions (XA) Depending on the approval, the following Safety Instructions (XA) are supplied with the device. They
are an integral part of the Operating Instructions.
The nameplate indicates the Safety Instructions (XA) that are relevant to the device.

Feature 010 Approval Feature 020 "Power Supply; Output"


1)
A B 2) C 3)

BA ATEX II 1G Ex ia IIC T6 Ga XA01549F XA01549F XA01549F

BB ATEX II 1/2G Ex ia IIC T6 Ga/Gb XA01549F XA01549F XA01549F

BC ATEX II 1/2G Ex ia/db [ia Ga] IIC T6 Ga/Gb XA01552F XA01552F XA01552F

BD ATEX II 1/2/3G Ex ia/ic [ia Ga] IIC T6 Ga/Gb/Gc XA01550F XA01550F XA01550F

BG ATEX II 3G Ex ec IIC T6 Gc XA01551F XA01551F XA01551F

BH ATEX II 3G Ex ic IIC T6 Gc XA01551F XA01551F XA01551F

BL ATEX II 1/2/3G Ex ia/ec [ia Ga] IIC T6 Ga/Gb/Gc XA01550F XA01550F XA01550F

B2 ATEX II 1/2G Ex ia IIC T6 Ga/Gb, 1/2D Ex ia IIIC T85°C Da/Db XA01555F XA01555F XA01555F

B3 ATEX II 1/2G Ex ia/db [ia Ga] IIC T6, Ga/Gb 1/2D Ex ta/tb IIIC T85°C Da/Db XA01556F XA01556F XA01556F

B4 ATEX II 1/2G Ex ia IIC T6 Ga/Gb, Ex ia/db [ia Ga] IIC T6 Ga/Gb XA01553F XA01553F XA01553F

CD CSA C/US DIP Cl.II,III Div.1 Gr.E-G * * *


4)
C2 CSA C/US IS Cl.I,II,III Div.1 Gr.A-G, NI Cl.1 Div.2, Ex ia * * *

C3 CSA C/US XP Cl.I,II,III Div.1 Gr.A-G, NI Cl.1 Div.2, Ex db * * *

C5 CSA C/US IS Cl.I Div.1 Gr.A-D, NI Cl.1 Div.2, Ex ia * * *

FA FM IS Cl.I Div.1 Gr.A-D * * *

FB FM IS Cl.I,II,III Div.1 Gr.A-G, AEx ia, NI Cl.1 Div.2 * * *

FD FM XP Cl.I,II,III Div.1 Gr.A-G, AEx db, NI Cl.1 Div.2 * * *

FE FM DIP Cl.II,III Div.1 Gr.E-G * * *

GA EAC Ex ia IIC T6 Ga XA01617F XA01617F XA01617F

GB EAC Ex ia IIC T6 Ga/Gb XA01617F XA01617F XA01617F

GC EAC Ex ia/db [ia Ga] IIC T6 Ga/Gb XA01618F XA01618F XA01618F

IA IEC Ex ia IIC T6 Ga XA01549F XA01549F XA01549F

Endress+Hauser 81
Micropilot FMR62

Feature 010 Approval Feature 020 "Power Supply; Output"


1)
A B 2) C 3)

IB IEC Ex ia IIC T6 Ga/Gb XA01549F XA01549F XA01549F

IC IEC Ex ia/db [ia Ga] IIC T6 Ga/Gb XA01552F XA01552F XA01552F

ID IEC Ex ia/ic [ia Ga] IIC T6 Ga/Gb/Gc XA01550F XA01550F XA01550F

IG IEC Ex ec IIC T6 Gc XA01551F XA01551F XA01551F

IH IEC Ex ic IIC T6 Gc XA01551F XA01551F XA01551F

IL IEC Ex ia/ec [ia Ga] IIC T6 Ga/Gb/Gc XA01550F XA01550F XA01550F

I2 IEC Ex ia IIC T6 Ga/Gb, Ex ia IIIC T85°C Da/Db XA01555F XA01555F XA01555F

I3 IEC Ex ia/db [ia Ga] IIC T6 Ga/Gb, Ex ta/tb IIIC T85°C Da/Db XA01556F XA01556F XA01556F

I4 IEC Ex ia IIC T6 Ga/Gb, Ex ia/db [ia Ga] IIC T6 Ga/Gb XA01553F XA01553F XA01553F

KA KC Ex ia IIC T6 Ga * * *

KB KC Ex ia IIC T6 Ga/Gb * * *

KC KC Ex ia/db [ia Ga] IIC T6 Ga/Gb * * *

MA INMETRO Ex ia IIC T6 Ga * * *

MC INMETRO Ex ia/db [ia Ga] IIC T6 Ga/Gb * * *

MH INMETRO Ex ic IIC T6 Gc * * *

NA NEPSI Ex ia IIC T6 Ga * * *

NB NEPSI Ex ia IIC T6 Ga/Gb * * *

NC NEPSI Ex ia/db [ia Ga] IIC T6 Ga/Gb * * *

NG NEPSI Ex ec IIC T6 Gc * * *

NH NEPSI Ex ic IIC T6 Gc * * *

N2 NEPSI Ex ia IIC T6 Ga/Gb, Ex iaD 20/21 T85...90°C * * *

N3 NEPSI Ex d[ia] IIC T6 Ga/Gb, DIP A20/21 T85…90oC IP66 * * *

8A FM/CSA IS+XP Cl.I,II,III Div.1 Gr.A-G * * *

1) 2-wire; 4-20mA HART


2) 2-wire; 4-20mA HART, switch output
3) 2-wire; 4-20mA HART, 4-20mA
4) in preparation

82 Endress+Hauser
*71375858*
71375858

www.addresses.endress.com

You might also like