FMR53 DS
FMR53 DS
FMR53 DS
Technical Information
Micropilot FMR53, FMR54
Free space radar
Application
• Continuous, non-contact level measurement of liquids, pastes and slurries
• Rod antenna (FMR53); horn or planar antenna (FMR54)
• Maximum measuring range: 20 m (66 ft);
for FMR54 with planar antenna in stilling well: 38 m (125 ft)
• Temperature: –196 to +400 °C (–321 to +752 °F)
• Pressure: –1 to +160 bar (–14.5 to +2 320 psi)
• Accuracy: ± 6 mm
• International explosion protection certificates; WHG; marine approvals
• Linearity protocol (3-point, 5-point)
Ihre Vorteile
• Reliable measurement even for changing product and process conditions
• HistoROM data management for easy commissioning, maintenance and
diagnostics
• Highest reliability due to Multi-Echo Tracking
• SIL2 according to IEC 61508, SIL3 in case of homogeneous or heterogeneous
redundancy
• Seamless integration into control or asset management systems
• Intuitive user interface in national languages
• Easy proof test for SIL and WHG
• Heartbeat Technology™
Micropilot FMR53, FMR54
Table of contents
2 Endress+Hauser
Micropilot FMR53, FMR54
Application Packages . . . . . . . . . . . . . . . . . . . . . . . 92
Heartbeat Diagnostics . . . . . . . . . . . . . . . . . . . . . . . . . 92
Heartbeat Verification . . . . . . . . . . . . . . . . . . . . . . . . . 93
Heartbeat Monitoring . . . . . . . . . . . . . . . . . . . . . . . . . 94
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95
Device-specific accessories . . . . . . . . . . . . . . . . . . . . . . 95
Communication-specific accessories . . . . . . . . . . . . . . . . 99
Service-specific accessories . . . . . . . . . . . . . . . . . . . . . 100
System components . . . . . . . . . . . . . . . . . . . . . . . . . . 100
Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . 101
Standard documentation . . . . . . . . . . . . . . . . . . . . . . . 101
Supplementary documentation . . . . . . . . . . . . . . . . . . . 101
Safety Instructions (XA) . . . . . . . . . . . . . . . . . . . . . . . 101
Patents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105
Endress+Hauser 3
Micropilot FMR53, FMR54
Symbol Meaning
DANGER!
DANGER This symbol alerts you to a dangerous situation. Failure to avoid this situation will
result in serious or fatal injury.
WARNING!
WARNING This symbol alerts you to a dangerous situation. Failure to avoid this situation can
result in serious or fatal injury.
CAUTION!
CAUTION This symbol alerts you to a dangerous situation. Failure to avoid this situation can
result in minor or medium injury.
NOTE!
NOTICE This symbol contains information on procedures and other facts which do not result in
personal injury.
Electrical symbols
Symbol Meaning
Direct current
Alternating current
Ground connection
A grounded terminal which, as far as the operator is concerned, is grounded via a
grounding system.
Equipotential connection
A connection that has to be connected to the plant grounding system: This may be a
potential equalization line or a star grounding system depending on national or
company codes of practice.
Symbol Meaning
Permitted
Procedures, processes or actions that are permitted.
Preferred
Procedures, processes or actions that are preferred.
Forbidden
Procedures, processes or actions that are forbidden.
Tip
Indicates additional information.
Reference to documentation
A Reference to page
Reference to graphic
Visual inspection
4 Endress+Hauser
Micropilot FMR53, FMR54
Symbols in graphics
Symbol Meaning
1. , 2. , 3. … Series of steps
A, B, C, ... Views
Hazardous area
- Indicates a hazardous area.
Symbol Meaning
Safety instructions
Observe the safety instructions contained in the associated Operating Instructions.
Endress+Hauser 5
Micropilot FMR53, FMR54
D
100%
F
L
0%
A0017871
Input
The reflected radar impulses are received by the antenna and transmitted into the electronics. A
microprocessor evaluates the signal and identifies the level echo caused by the reflection of the radar
impulse at the product surface. The unambiguous signal identification is accomplished by the
PulseMaster® eXact software together with the Multi-echo tracking algorithms, based on many
years of experience with time-of-flight technology.
The distance D to the product surface is proportional to the time of flight t of the impulse:
D = c · t/2,
with c being the speed of light.
Based on the known empty distance E, the level L is calculated:
L=E–D
The reference point R of the measurement is located at the process connection. For details see the
dimensional drawing:
• FMR53: → 62
• FMR54: → 65
The Micropilot is equipped with functions to suppress interference echoes. The user can activate
these functions. Together with the multi-echo tracking algorithms they ensure that interference
echoes (i.e. from edges and weld seams) are not interpreted as level echo.
6 Endress+Hauser
Micropilot FMR53, FMR54
Output
The Micropilot is commissioned by entering an empty distance "E" (=zero), a full distance "F" (=span)
and application parameters which automatically adapt the instrument to the process conditions. For
models with a current output, the factory adjustment for zero point "E" and span "F" is 4 mA and 20
mA. For digital outputs and the display module, the factory adjustment for zero point "E" and span "F"
is 0 % and 100 %.
A linearization with max. 32 points, based on a table entered either manually or semi-automatically,
can be activated locally or remotely. This function provides a measurement in engineering units and
a linear output signal for spheres, horizontal cylindrical tanks and vessels with conical outlet.
Endress+Hauser 7
Micropilot FMR53, FMR54
Input
Measured variable The measured variable is the distance between the reference point and the product surface.
The level is calculated from this distance, taking into account the empty distance "E" entered by the
user.
If required, the level can be converted into other variables (volume, mass) by means of a linearization
(up to 32 points).
Media groups
Media groups DC (εr) Example
D > 10 conducting liquids, e.g. aqueous solutions, dilute acids and alkalis
For dielectric constants (DC values) of many media commonly used in various industries refer
to:
• the Endress+Hauser DC manual (CP01076F)
• the Endress+Hauser "DC Values App" (available for Android and iOS)
8 Endress+Hauser
Micropilot FMR53, FMR54
A0018833
A0018835
FMR54 1) Horn 150 mm (6 in) Horn 200 mm (8 in) Horn 150 mm (6 in) Horn 200 mm (8 in)
Horn 250 mm (10 in) Horn 250 mm (10 in)
B C D B C D B C D B C D
5
(16)
7.5 7.5
(25) (25)
10 10 10
(33) (33) (33)
12.5
A0018846
(41)
15 15
A0018847
(49) (49)
20 20 20
(66) (66) (66)
A0018844 A0018845
1) FMR54 with the antenna version BC (80mm/3") and BD: (100mm/4") should not be mounted directly in the tank. They are only suited for
bypasses or stilling wells.
Endress+Hauser 9
Micropilot FMR53, FMR54
A0018840
A0018839
A0018837
FMR53 Rod - - - -
390 mm (15 in)
Rod
540 mm (21 in)
B C D B C D A, B, C, D A, B, C, D C, D
4
(13) 6 6
(20) 8 (20) 8
(26) (26)
10
A0018848 (33)
A0018850
20 20
(66) (66)
A0018851 A0018852
38
(125)
A0018854
10 Endress+Hauser
Micropilot FMR53, FMR54
Endress+Hauser 11
Micropilot FMR53, FMR54
Output
Output signal HART
PROFIBUS PA
FOUNDATION Fieldbus
Switch output
For HART devices, the switch output is available as an option. See product structure, feature 20:
"Power Supply, Output", option B: "2-wire; 4-20mA HART, switch output"
Devices with PROFIBUS PA and FOUNDATION Fieldbus always have a switch output.
Switch output
Switching behavior Binary (conductive or non-conductive), switches when the programmable switch
point is reached
Insulation voltage floating, Insulation voltage 1 350 VDC to power supply aund 500 VAC to ground
Switch point freely programmable, separately for switch-on and switch-off point
Switching delay freely programmable from 0 to 100 s, separately for switch-on and switch-off
point
12 Endress+Hauser
Micropilot FMR53, FMR54
Linearization The linearization function of the device allows the conversion of the measured value into any unit of
length or volume. Linearization tables for calculating the volume in cylindrical tanks are pre-
programmed. Other linearization tables of up to 32 value pairs can be entered manually or semi-
automatically.
Galvanic isolation All circuits for the outputs are galvanically isolated from each other.
Manufacturer ID 17 (0x11)
HART device variables The measured values can be freely assigned to the device variables.
Measured values for PV (primary variable)
• Level linearized
• Distance
• Electronic temperature
• Relative echo amplitude
• Area of incoupling
• Analog output adv. diagnostics 1
• Analog output adv. diagnostics 2
Measured values for SV, TV, FV (second, third and fourth variable)
• Level linearized
• Distance
• Electronic temperature
• Terminal voltage
• Relative echo amplitude
• Absolute echo amplitude
• Area of incoupling
• Analog output adv. diagnostics 1
• Analog output adv. diagnostics 2
Start-up time 40 s
Endress+Hauser 13
Micropilot FMR53, FMR54
Set-up time 1s
PROFIBUS PA
Manufacturer ID 17 (0x11)
FOUNDATION Fieldbus
Manufacturer ID 0x452B48
14 Endress+Hauser
Micropilot FMR53, FMR54
Number of VCRs 44
Permanent entries 1
Client VCRs 0
Server VCRs 10
Source VCRs 43
Sink VCRs 0
Subscriber VCRs 43
Publisher VCRs 43
Slot time 4
Transducer Blocks
Block Content Output values
Setup Transducer Block Contains all parameters for a standard commissioning • Level or volume 1)
procedure (Channel 1)
• Distance (Channel 2)
Advanced Setup Contains all parameters for a more detailed no output values
Transducer Block configuration of the device
Display Transducer Block Contains all parameters for the configuration of the no output values
display module
Advanced Diagnostic Contains parameters for the Advanced Diagnostic no output values
Transducer Block
Expert Configuration Contains parameters which require detailed knowledge no output values
Transducer Block of the functionalities of the device
Expert Information Contains information about the state of the device no output values
Transducer Block
Service Sensor Transducer Contains parameters which can only be operated by no output values
Block Endress+Hauser service personnel
Service Information Contains information on the state of device which is no output values
Transducer Block relevant for service operations
Data Transfer Transducer Contains parameters which allow to backup the device no output values
Block configuration in the display module and to restore it
into the device. Access to these parameters is restricted
to the Endress+Hauser service.
Endress+Hauser 15
Micropilot FMR53, FMR54
Function Blocks
Block Content Number of Number of Execution Functionality
permanent instantiable time
blocks blocks
16 Endress+Hauser
Micropilot FMR53, FMR54
Up to 20 blocks can be instantiated in the device altogether, including the blocks already
instantiated on delivery.
Endress+Hauser 17
Micropilot FMR53, FMR54
Power supply
Terminal assignment 2-wire: 4-20mA HART
! 2- w
4-2 ire le
0 vel
HA mA
[21 RT
4-2
0m
A ]
ope
A
n Sp
a
711 re pa
HA 20mA
08x rt
xx
RT
4...
+
1 -
1 2 4 5 6
mm
2
10
+ +
–
–
# 4...20 mA
3 B
7 +
1-c 1 -
1 2 4 5 han
nel 4-2 2
ove 0m
[16
] rvo A
ltag
e pro
tec
tion
+ +
–
–
# 4...20 mA
3
A0011294
18 Endress+Hauser
Micropilot FMR53, FMR54
10
9
8
% 2- w
4-2 ire
0
HA mA
[02 RT
PF
S
A /03
] ope
n Sp
a
711 re pa
HA 20 mA
08x rt
3+ ++ xx
31 --
RT
4...
42 +
7
1 -
mm
2 6
4-
10
+ +
–
-
≥250 Ω 4...20 mA
$
1 2 3 4 5 B
3+ 11 +
3 -
4-2 4
0m +
2-c
A / 1 -
han 4-2 2
4- [17
n el o
v erv FIE 0mA
] olta LD /
ge BU
pro S
tec
tion
+ +
–
-
≥250 Ω 4...20 mA
$
1 2 3 4 5
A0013759
Endress+Hauser 19
Micropilot FMR53, FMR54
14
13
12
# 2- w
4-2 ire le
0 v el
HA mA
[04 RT
4-2
0m
A /05
]
A
ope
A
n
20m
Sp
a
711 re pa
HA 20mA
08x rt
xx
+
4...
3 -
RT
11
4...
4 +
1 -
mm
2
+ +
10
1 " –
-
4...20 mA
9 8 4
+ +
2 " –
-
4...20 mA
3 5 6 7 4
B
+ +
1 " –
- +
3 -
4...20 mA 4-2 4
10 0m +
9 8 4 2-c
A / 1 -
han
nel 4- 2
[17
ove FIE 20mA
] rvo LD /
ltag
ep
B U
ro S
tec
tion
+ +
2 " –
-
4...20 mA
3 5 6 7 4
A0013923
This version is also suited for single-channel operation. In this case, current output 1 (terminals
1 and 2) must be used.
20 Endress+Hauser
Micropilot FMR53, FMR54
13
12
11
! 2- w
4-2 ire
0
HA mA
[08 RT
A ]
V=
ope
48
n Sp
4...
a
711 re pa
HA 20 mA
08x rt
10.
L+ xx
1 L-
RT
4...
2 +
10 9
3 -
mm
4 8
10
7
+ !
-
≥250 Ω 4...20 mA
6
1 2 3 4 5
A0011340
Endress+Hauser 21
Micropilot FMR53, FMR54
13
12
11
! 2- w
4-2 ire
0
HA mA
[09 RT
A ]
~
3V
ope
n
..25
Sp
a
711 re pa
HA 20 mA
90.
08x rt
xx
L
1 N
RT
4...
2 +
10 9
3 -
mm
4 8
10
7
+ !
-
≥250 Ω 4...20 mA
6
1 2 3 4 5
A0018965
LCAUTION
To ensure electrical safety:
‣ Do not disconnect the protective connection (6).
‣ Disconnect the supply voltage before disconnecting the protective earth (7).
Connect protective earth to the internal ground terminal (7) before connecting the supply
voltage. If necessary, connect the potential matching line to the external ground terminal (11).
In order to ensure electromagnetic compatibility (EMC): Do not only ground the device via the
protective earth conductor of the supply cable. Instead, the functional grounding must also be
connected to the process connection (flange or threaded connection) or to the external ground
terminal.
An easily accessible power switch must be installed in the proximity of the device. The power
switch must be marked as a disconnector for the device (IEC/EN61010).
22 Endress+Hauser
Micropilot FMR53, FMR54
! 2-
F4IEwire
-20L lev
mD
ABU el
P
FAIE/F S
26/ LD
[0 F B PFS
A 07]
2 U S
op en Sp
a
7110 re pa
S
0283x4 rt
BU
3+ ++ x5x7
/LFDF
31 --
PIAE
42 +
F
2
1 2-
mm
4-
10
3
1
B
3+ 6 +
3 -
4-2 4
0m +
2-c
A/ 1 -
han
nel 4-2 2
4- [17
o ver F IEL 0m
A
] volt
age DB /
1 pro
tec
US
tion
A0011341
Endress+Hauser 23
Micropilot FMR53, FMR54
+
3+ 1
2
+ 3+
-
4-
A0015909
4-
8 Connection of a relay A0015910
24 Endress+Hauser
Micropilot FMR53, FMR54
Device plug connectors For the versions with fieldbus plug connector (M12 or 7/8"), the signal line can be connected
without opening the housing.
2 not connected
1 2 3 Signal -
A0011175
4 Ground
2 Signal +
2 4 3 Not connected
A0011176
4 Screen
Endress+Hauser 25
Micropilot FMR53, FMR54
"Power Supply, Output" 1) "Approval" 2) Terminal voltage U at the Maximum load R, depending on the supply voltage U0 at the
device supply unit
Ex ia / IS 10.4 to 30 V 3)
0
10 20 30 35 U0 [V]
10.4 21.4
A0017140
4)
• Ex d(ia) / XP 12 to 35 V R [W]
• Ex ic(ia)
• Ex nA(ia) 500
• Ex ta / DIP
Ex ia + Ex d(ia) / IS + XP 12 to 30 V 4)
0
10 20 30 35 U0 [V]
12 23
A0019136
"Power Supply, Output" 1) "Approval" 2) Terminal voltage U Maximum load R, depending on the supply voltage U0 at the
at the device supply unit
• Ex ia / IS 12 to 30 V 3)
0
• Ex ia + Ex d(ia) / IS + XP
10 20 30 35 U0 [V]
12 23
A0019136
26 Endress+Hauser
Micropilot FMR53, FMR54
"Power Supply, Output" 1) "Approval" 2) Terminal voltage U at the Maximum load R, depending on the supply voltage U0 at the
device supply unit
0
10 20 30 U0 [V]
12 23
A0017055
Endress+Hauser 27
Micropilot FMR53, FMR54
Polarity sensitive No
Nominal current 3.6 to 22 mA, the start-up current for multidrop mode can be parametrized (is
set to 3.6 mA on delivery)
PROFIBUS PA
Nominal current 14 mA
28 Endress+Hauser
Micropilot FMR53, FMR54
FOUNDATION Fieldbus
FISCO
Ui 17.5 V
Ii 550 mA
Pi 5.5 W
Ci 5 nF
Li 10 μH
Endress+Hauser 29
Micropilot FMR53, FMR54
HART
• A normal device cable suffices if only the analog signal is used.
• A shielded cable is recommended if using the HART protocol. Observe grounding concept of the
plant.
• For 4-wire devices: Standard device cable is sufficient for the power line.
PROFIBUS
Use a twisted, screened two-wire cable, preferably cable type A.
For further information on the cable specifications, see Operating Instructions BA00034S
"PROFIBUS DP/PA: Guidelines for planning and commissioning", PNO Guideline 2.092
"PROFIBUS PA User and Installation Guideline" and IEC 61158-2 (MBP).
FOUNDATION Fieldbus
Endress+Hauser recommends using twisted, shielded two-wire cables.
For further information on the cable specifications, see Operating Instructions BA00013S
"FOUNDATION Fieldbus Overview", FOUNDATION Fieldbus Guideline and IEC 61158-2 (MBP).
Overvoltage protection If the measuring device is used for level measurement in flammable liquids which requires the use of
overvoltage protection according to DIN EN 60079-14, standard for
test procedures 60060-1 (10 kA, pulse 8/20 μs), overvoltage protection has to be ensured by an
integrated or external overvoltage protection module.
Technical data
30 Endress+Hauser
Micropilot FMR53, FMR54
Performance characteristics
Reference operating • Temperature = +24 °C (+75 °F) ±5 °C (±9 °F)
conditions • Pressure = 960 mbar abs. (14 psia) ±100 mbar (±1.45 psi)
• Humidity = 60 % ±15 %
• Reflector: metal plate with a minimum diameter of 1 m (40 in)
• No major interference reflections inside the signal beam
Maximum measured error Typical data under reference operating conditions: DIN EN IEC 61298-2 / DIN EN IEC 60770-1;
percentage values in relation to the span.
digital analog 1)
1) Only relevant for 4-20mA current output; add error of the analog value to the digital value.
Measured value resolution Dead band according to DIN EN IEC 61298-2 / DIN EN IEC 60770-1:
• digital: 1 mm
• analog: 1 μA
Reaction time The reaction time can be parametrized. The following step response times (as per DIN EN IEC
61298-2 / DIN EN IEC 60770-1) 1)are valid if the damping is switched off:
Influence of ambient The measurements are carried out in accordance with DIN EN IEC 61298-3 / DIN EN IEC
temperature 60770-1
• Digital (HART, PROFIBUS PA, FOUNDATION Fieldbus): average TK = 3 mm/10 K
• Analog (current output):
– zero point (4 mA): average TK = 0.02 %/10 K
– span (20 mA): average TK = 0.05 %/10 K
Influence of gas layer High pressures reduce the propagation velocity of the measuring signals in the gas/vapor above the
fluid. This effect depends on the kind of gas/vapor and of its temperature. This results in a
systematic measuring error that gets bigger as the distance increases between the reference point of
the measurement (flange) and the product surface. The following table illustrates this measured
error for a few typical gases/vapors (with regard to distance; a positive value means that too large a
distance is being measured):
°C °F 1 bar (14,5 psi) 10 bar (145 psi) 50 bar (725 psi) 100 bar (1450 psi) 160 bar (2320 psi)
1) According to DIN EN IEC 61298-2 / DIN EN IEC 60770-1 the response time is the time which passes after a sudden change of the input signal
until the output signal for the first time assumes 90% of the steady-state value.
Endress+Hauser 31
Micropilot FMR53, FMR54
°C °F 1 bar (14,5 psi) 10 bar (145 psi) 50 bar (725 psi) 100 bar (1450 psi) 160 bar (2320 psi)
310 590 - - - 22 % -
When the pressure is known and constant, this measured error can, for example, be
compensated by means of a linearization.
Gas phase compensation PROFIBUS devices can receive the signal of an external pressure sensor through the bus and use it to
with external pressure perform a pressure dependent time-of-flight correction. In the case of saturated steam in the
sensor (PROFIBUS PA, temperature range from 100 to 350 °C (212 to 662 °f), for example, the measuring error of the
FOUNDATION Fieldbus) distance measurement can be reduced by this method from up to 29 % (without compensation) to
less than 3 % (with compensation).
32 Endress+Hauser
Micropilot FMR53, FMR54
Installation
Installation conditions Mounting position
A0016882
Vessel installations
A0018944
Endress+Hauser 33
Micropilot FMR53, FMR54
A0016890
3
1
A0017123
34 Endress+Hauser
Micropilot FMR53, FMR54
Optimization options
• Antenna size
The bigger the antenna, the smaller the beam angle α and the fewer interference echoes
→ 35.
• Mapping
The measurement can be optimized by means of electronic suppression of interference echoes.
• Antenna alignment
Take into account the marker on the flange or threaded connection → 38 → 39 .
• Stilling well
A stilling well can be applied to avoid interferences → 41.
• Metallic screens mounted at a slope
They spread the radar signals and can, therefore, reduce interference echoes.
Beam angle
a
W = 2 . D . tan _
2
D
a
A0016891
The beam angle is defined as the angle α where the energy density of the radar waves reaches half
the value of the maximum energy density (3-dB-width). Microwaves are also emitted outside the
signal beam and can be reflected off interfering installations.
Beam diameter W as a function of beam angle α and measuring distance D:
FMR53
Endress+Hauser 35
Micropilot FMR53, FMR54
6 m (20 ft) 2.44 m (8 ft) 2.01 m (6.6 ft) 1.58 m (5.2 ft)
9 m (30 ft) 3.66 m (12 ft) 3.01 m (9.9 ft) 2.37 m (7.8 ft)
12 m (39 ft) 4.88 m (16 ft) 4.02 m (13 ft) 3.16 m (10 ft)
15 m (49 ft) 6.1 m (20 ft) 5.02 m (16 ft) 3.95 m (13 ft)
20 m (66 ft) 8.14 m (27 ft) 6.69 m (22 ft) 5.27 m (17 ft)
Measuring conditions • In case of boiling surfaces, bubbling or tendency for foaming use FMR53 or FMR54. Depending
on its consistence, foam can either absorb microwaves or reflect them off the foam surface.
Measurement is possible under certain conditions. For FMR50, FMR51 and FMR52, the additional
option "Advanced dynamics" is recommended in these cases (feature 540: "Application Package",
option EM).
• In case of heavy steam development or condensate, the maximum measuring range of FMR50,
FMR51 and FMR52 may decrease depending on density, temperature and composition of the
steam → use FMR53 or FMR54.
• For the measurement of absorbing gases such as ammonia NH3 or some fluorocarbons 2), please
use Levelflex or Micropilot FMR54 in a stilling well.
• The measuring range begins, where the beam hits the tank bottom. Particularly with dish bottoms
or conical outlets the level cannot be detected below this point.
• In stilling well applications, the electromagnetic waves do not propagate completely outside the
tube. It must be taken into account that the accuracy may be reduced in the area C. In order to
guarantee the required accuracy in these cases, it is recommended to position the zero-point at a
distance C above the end of the tube (see figure).
• In case of media with a low dielectric constant (εr = 1.5 to 4) 3) the tank bottom can be visible
through the medium at low levels (low height C). Reduced accuracy has to be expected in this
range. If this is not acceptable, we recommend positioning the zero point at a distance C (see
figure) above the tank bottom in these applications.
• In principle it is possible to measure up to the tip of the antenna with FMR51, FMR53 and FMR54.
However, due to considerations regarding corrosion and build-up, the end of the measuring range
should not be chosen any closer than A (see figure) to the tip of the antenna.
• When using FMR54 with planar antenna, especially for media with low dielectric constants, the
end of the measuring range should not be closer than A: 1 m (3.28 ft) to the flange.
• The smallest possible measuring range B depends on the antenna version (see figure).
• The tank height should be at least H (see table).
36 Endress+Hauser
Micropilot FMR53, FMR54
A
100%
H
B
C
0%
øD
A0018872
Device A B C H
Mounting cladded flanges For cladded flanges of FMR53, observe the following:
• Use flange screws according to the number of flange holes.
• Tighten the screws with the required torque (see table).
• Retighten the screws after 24 hours or after the first temperature cycle.
• Depending on process pressure and process temperature check and retighten the screws at
regular intervals.
Usually, the PTFE flange cladding also serves as a seal between the nozzle and the device
flange.
minimum maximum
EN
DN50/PN16 4 45 65
DN80/PN16 8 40 55
DN100/PN16 8 40 60
DN150/PN16 8 75 115
ASME
2"/150lbs 4 40 55
3"/150lbs 4 65 95
4"/150lbs 8 45 70
6"/150lbs 8 85 125
Endress+Hauser 37
Micropilot FMR53, FMR54
minimum maximum
JIS
10K 50A 4 40 60
10K 80A 8 25 35
10K 100A 8 35 55
A B
°
90
°
90
°
90
° °
°
90 90
90
90 90
° °
90 90
° °
A0018974
Depending on the device version the marking may be a circle or two short parallel lines.
38 Endress+Hauser
Micropilot FMR53, FMR54
Nozzle mounting
H
1 1
2 2
A0016821
Nozzle height H < 100 mm (3.94 in) < 250 mm (9.84 in)
The inactive part (1) of the rod antenna must extend below the nozzle.
• For flanges with PTFE cladding: Observe the notes on the mounting of cladded flanges
→ 37.
• Usually, the PTFE flange cladding also serves as a seal between the nozzle and the device
flange.
Threaded connection
• Tighten with the hexagonal nut only.
• Tool : 55 mm hexagonal wrench
• Maximum permissible torque:
– Thread PVDF: 35 Nm (26 lbf ft)
– Thread 316L: 60 Nm (44 lbf ft)
Alignment
• Align the antenna vertically to the product surface.
• A marking at the flange (somwhere between the flange holes) enables alignment of the antenna.
This marking must be aligned towards the tank wall as well as possible.
Endress+Hauser 39
Micropilot FMR53, FMR54
A B
°
90
°
90
°
90
° °
°
90 90
90
90 90
° °
90 90
° °
A0018974
Depending on the device version the marking may be a circle or two short parallel lines.
Nozzle mounting
The horn antenna must extend below the nozzle; if necessary select the device version with antenna
extension 100 to 400 mm (4 to 16 in) 4).
øD
A0016822
1) Feature 070 of the product structure; the antenna versions BC (Horn 80mm/3") and BD (Horn 100mm/4")
should not be mounted directly into the tank. They are only suited for bypass and stilling well applications.
2) valid for antennas without antenna extension
4) See product structure: feature 610 "Accessory Mounted", options OM, ON, OR, OS.
40 Endress+Hauser
Micropilot FMR53, FMR54
Optimum thickness 16 mm (0.65 in) 17 mm (0.68 in) 16 mm (0.65 in) 14 mm (0.56 in)
°
90
A0016841
• For horn antenna: Align the marking towards the slots of the stilling well.
• No alignment is required for planar antennas.
• Measurements can be performed through an open full bore ball valve without any problems.
• After mounting, the housing can be turned 350° in order to facilitate access to the display and the
terminal compartment.
Endress+Hauser 41
Micropilot FMR53, FMR54
• The stilling well must be smooth on the inside (average roughness Rz ≤ 6.3 μm (248 μin)). Use
extruded or parallel welded metal pipe. An extension of the pipe is possible with welded flanges or
pipe sleeves. Flange and pipe have to be properly aligned at the inside.
• Do not weld through the pipe wall. The inside of the stilling well must remain smooth. In case of
unintentional welding through the pipe, the weld seam and any unevenness on the inside need to
be carefully removed and smoothened. Otherwise, strong interference echoes will be generated
and material build-up will be promoted.
• In the case of smaller nominal widths flanges must be welded to the pipe such that they allow for a
correct orientation (marker aligned toward slots).
The performance of Micropilot FMR54 with planar antenna is not dependent on the alignment
or geometry of standard stilling wells. No special alignment is required. However, make sure
that the planar antenna is installed vertically relative to the stilling well axis.
42 Endress+Hauser
Micropilot FMR53, FMR54
A B A-A
A A 1
1 C
2 3
100%
100%
4
5
(5.91...19.7)
150…500
≤ 1 (0.04)
(5.91...19.7)
150…500
≤ 1 (0.04)
D 6
0%
0%
mm (in)
A0019009
Endress+Hauser 43
Micropilot FMR53, FMR54
Installation in bypass
°
90
1
°
90
A0019446
14 Installation in bypass
1 Marking for antenna alignment
2 Tank connectors
44 Endress+Hauser
Micropilot FMR53, FMR54
A
A-A
A A
≤ 1 (0.04)
2
C
(7.87) (7.87)
200
100%
200
3
4 B
4
3
(7.87) (7.87)
200
0%
200
mm (in)
A0019010
Endress+Hauser 45
Micropilot FMR53, FMR54
1
2
A0019142
If process temperatures are high, the device must be included in normal tank insulation to prevent
the electronics heating up as a result of heat radiation or convection. The insulation may not exceed
beyond the neck of the housing.
46 Endress+Hauser
Micropilot FMR53, FMR54
Environment
Ambient temperature range Measuring device –40 to +80 °C (–40 to +176 °F); –50 °C (–58 °F) with manufacturer declaration on
request
Local display –20 to +70 °C (–4 to +158 °F), the readability of the display may be impaired at
temperatures outside the temperature range.
Ambient temperature limits The following diagrams take into account only functional aspects. There may be further
restrictions for certified device versions. Please refere to the separate Safety Instructions
→ 101.
With a temperature (Tp) at the process connection the admissible ambient temperature (Ta) is
reduced according to the following diagram (temperature derating):
FMR53 Ta
Process connection: Thread PVDF P1 P2
Housing: GT18 (316 L) P3
Temperature unit: °C (°F)
Tp
P5 P4
A0019351
Endress+Hauser 47
Micropilot FMR53, FMR54
FMR53 Ta
Process connection: Thread PVDF P1 P2
Housing: GT18 (316 L) P3
Temperature unit: °C (°F)
Tp
P5 P4
A0019351
FMR53 Ta
Process connection: Thread PVDF P1 P2
Housing: GT19 (Plastics PBT) P3
Temperature unit: °C (°F)
Tp
P5 P4
A0019351
FMR53 Ta
Process connection: Thread PVDF P1 P2
Housing: GT20 (Alu, coated) P3
Temperature unit: °C (°F)
Tp
P5 P4
A0019351
48 Endress+Hauser
Micropilot FMR53, FMR54
FMR53 Ta
Process connection: Thread PVDF P1 P2
Housing: GT20 (Alu, coated) P3
Temperature unit: °C (°F)
Tp
P5 P4
A0019351
FMR53 Ta
P1 P2
Process connection:
• Thread 316L P3
• Flange
Housing: GT18 (316 L) Tp
Temperature unit: °C (°F) P5 P4
A0019351
Endress+Hauser 49
Micropilot FMR53, FMR54
FMR53 Ta
P1 P2
Process connection:
• Thread 316L P3
• Flange
Housing: GT19 (Plastics PBT) Tp
Temperature unit: °C (°F) P5 P4
A0019351
FMR53 Ta
P1 P2
Process connection:
• Thread 316L P3
• Flange
Housing: GT20 (Alu, coated) Tp
Temperature unit: °C (°F) P5 P4
A0019351
50 Endress+Hauser
Micropilot FMR53, FMR54
FMR54 Ta
Horn antenna P1 P2
Seal: P3
• Viton
• EPDM Tp
• Kalrez P5 P4
Housing: GT18 (316 L) A0019351
FMR54 Ta
Horn antenna P1 P2
Seal: P3
• Viton
• EPDM Tp
• Kalrez P5 P4
Housing: GT19 (Plastics PBT) A0019351
Endress+Hauser 51
Micropilot FMR53, FMR54
FMR54 Ta
Horn antenna P1 P2
Seal: P3
• Viton
• EPDM Tp
• Kalrez P5 P4
Housing: GT20 (Alu, coated) A0019351
FMR54 Ta
Horn antenna P1 P2
Seal: Graphite –196 to 280 °C (–321 to 536 °F) P3
Housing: GT18 (316 L)
Temperature unit: °C (°F)
P6 Tp
P5 P4
A0019344
52 Endress+Hauser
Micropilot FMR53, FMR54
FMR54 Ta
Horn antenna P1 P2
Seal: Graphite –196 to 280 °C (–321 to 536 °F) P3
Housing: GT19 (Plastics PBT)
Temperature unit: °C (°F)
P6 Tp
P5 P4
A0019344
FMR54 Ta
Horn antenna P1 P2
Seal: Graphite –196 to 280 °C (–321 to 536 °F) P3
Housing: GT20 (Alu, coated)
Temperature unit: °C (°F)
P6 Tp
P5 P4
A0019344
Endress+Hauser 53
Micropilot FMR53, FMR54
FMR54 Ta
Horn antenna P1 P2
Seal: Graphite –196 to 400 °C (–321 to 752 °F) P3
Housing: GT18 (316 L)
Temperature unit: °C (°F)
P6 Tp
P5 P4
A0019344
FMR54 Ta
Horn antenna P1 P2
Seal: Graphite –196 to 400 °C (–321 to 752 °F) P3
Housing: GT19 (Plastics PBT)
Temperature unit: °C (°F)
P6 Tp
P5 P4
A0019344
54 Endress+Hauser
Micropilot FMR53, FMR54
FMR54 Ta
Horn antenna P1 P2
Seal: Graphite –196 to 400 °C (–321 to 752 °F) P3
Housing: GT20 (Alu, coated)
Temperature unit: °C (°F)
P6 Tp
P5 P4
A0019344
FMR54 Ta
Planar antenna P1 P2
Housing: GT18 (316 L) P3
Temperature unit: °C (°F)
Tp
P5 P4
A0019351
Endress+Hauser 55
Micropilot FMR53, FMR54
FMR54 Ta
Planar antenna P1 P2
Housing: GT19 (Plastics PBT) P3
Temperature unit: °C (°F)
Tp
P5 P4
A0019351
FMR54 Ta
Planar antenna P1 P2
Housing: GT20 (Alu, coated) P3
Temperature unit: °C (°F)
Tp
P5 P4
A0019351
56 Endress+Hauser
Micropilot FMR53, FMR54
Cleaning the antenna The antenna can get contaminated, depending on the application. The emission and reception of
microwaves can thus eventually be hindered. The degree of contamination leading to an error
depends on the medium and the reflectivity, mainly determined by the dielectric constant εr.
If the medium tends to cause contamination and deposits, cleaning on a regular basis is
recommended. Care has to be taken not to damage the antenna in the process of a mechanical or
hose-down cleaning. The material compatibility has to be considered if cleaning agents are used! The
maximum permitted temperature at the flange should not be exceeded.
Electromagnetic Electromagnetic compatibility to all relevant requirements of the EN 61326- series and NAMUR
compatibility (EMC) recommendation EMC (NE21). For details see declaration of conformity. 6).
If only the analogue signal is used, unshielded interconnection lines are sufficient for the
installation. In case of using the digital signal (HART/ PA/ FF) use shielded interconnection lines.
Max. fluctuations during EMC- tests: < 0.5 % of the span. As an exception to this, the maximum
fluctuations may amount to 2 % of the span for devices with plastic housing and see-through lid
(integrated display SD02 or SD03) if strong electromagnetic interferences in the frequenency range
of 1 to 2 GHz are present.
5) This restriction is valid if the following options of the product structure have been selected at the same time: 030 ("Display, Operation") = C
("SD02") or E ("SD03"); 040 ("Housing") = A ("GT19").
6) Can be downloaded from www.endress.com.
Endress+Hauser 57
Micropilot FMR53, FMR54
Process
Process temperature, Process
The specified pressure range may be reduced due to the selected process connection. The
pressure
pressure rating (PN) specified on the flanges refers to a reference temperature of 20 °C, for
ASME flanges 100 °F. Pay attention to pressure-temperature dependencies.
Please refer to the following standards for the pressure values permitted for higher
temperatures:
• EN 1092-1: 2001 Tab. 18
With regard to their temperature stability properties, the materials 1.4435 and 1.4404 are
grouped under 13E0 in EN 1092-1 Tab. 18. The chemical composition of the two materials
can be identical.
• ASME B 16.5a - 1998 Tab. 2-2.2 F316
• ASME B 16.5a - 1998 Tab. 2.3.8 N10276
• JIS B 2220
FMR53
[bar] ([psi]) p
1 2
40 (580)
3 (43.5)
0 (0)
-1 (-14.5) Tp
-40 0 +80 +150 [°C]
(-40) (+32) (+176) (+302) ([°F])
A0023251-EN
Feature 100 "Process connection" Admissible process temperature Admissible process pressure
• RGF: Thread ANSI MNPT1-1/2, –40 to +80 °C (–40 to +176 °F) prel = –1 to 3 bar (–14.5 to 43.5 psi)
PVDF pabs < 4 bar (58 psi)
• RVF: Thread EN10226 R1-1/2,
PVDF
Any other process connection –40 to +150 °C (–40 to +302 °F) prel = –1 to 40 bar (–14.5 to 580 psi)
58 Endress+Hauser
Micropilot FMR53, FMR54
FMR54
[bar] ([psi]) p
1 2
64 (928)
0 (0)
-1 (-14.5) Tp
-40 0 +150 +200 [°C]
(-40) (+32) (+302)(+392) ([°F])
[bar] ([psi]) p
3 4
64 (928)
0 (0)
-1 (-14.5) Tp
-40 -20 0 +150 +200 [°C]
(-40) (-4) (+32) (+302)(+392) ([°F])
[bar] ([psi]) p
5 6
160 (2320)
100 (1450)
0 (0)
-1 (-14.5) Tp
-196 0 +280 +400 [°C]
(-321) (+32) (+536)(+752) ([°F])
A0023254-EN
16 FMR54 with horn antenna: Admissible range of process temperature and process pressure
1 Seal: Viton (Feature 090 "Seal", Option A8); valid for conductive media
2 Seal: Viton (Feature 090 "Seal", Option A8); enlarged area for non-conductive media
3 Seal: EPDM (Feature 090 "Seal", Option B4)
4 Seal: Kalrez
5 Seal: Graphite (XT) (Feature 090 "Seal", Option D1)
6 Seal: Graphite (HT) (Feature 090 "Seal", Option D2)
Endress+Hauser 59
Micropilot FMR53, FMR54
prel
[bar] ([psi])
25 (375)
20 (300)
10 (150)
5 (75)
-20 (-4)
80 (+176)
100 (+212)
120 (+248)
150 (+302)
[°C] ([°F])
Tp
A0020552-EN
17 FMR54 with planar antenna: Admissible range of process temperature and process pressure
• AA: W/o horn, for pipe installation A8: Viton • conductive media: –1 to 64 bar
• BC: Horn 80mm/3" –40 to +150 °C (–14.5 to 928 psi)
• BD: Horn 100mm/4" (–40 to +302 °F)
• BE: Horn 150mm/6" • non-conductive media:
• BF: Horn 200mm/8" –40 to +200 °C
• BG: Horn 250mm/10" (–40 to +392 °F)
• DA: Planar 150mm/6" A7: Viton –20 to +150 °C Dependent on the process
• DB: Planar 200mm/8" (–4 to +302 °F) temperature, TP;, see the
• DC: Planar 250mm/10" diagram above
• DD: Planar 300mm/12"
1) For devices with CRN approval the pressure range may be reduced → 84
60 Endress+Hauser
Micropilot FMR53, FMR54
Mechanical construction
Dimensions Dimensions of the electronics housing
R100 98 (3.86)*
78 (3.07) 90 (3.54)
07)
(4.
141.9 (5.59)
3.5
ø108.5 (4.27)
144 (5.67)
115.25 (4.54)
ø10 A0011666
R100
99.5 (3.92)*
78 (3.07) 90 (3.54)
)
.17
6 (4
144 (5.67)
ø10
ø106 (4.17)
134.5 (5.3)
A0011346
R100 97 (3.82)*
78 (3.07) 90 (3.54)
7)
4.0
(
141.5 (5.57)
3.5
ø104.5 (4.11)
144 (5.67)
117.1 (4.61)
ø108.5 (4.27)
ø10
A0020751
Endress+Hauser 61
Micropilot FMR53, FMR54
A B
101.5 (4)
99.5 (3.92)
b
b
øD øD
L2
L2
ø33 (1.3) ø33 (1.3)
L1
L1
A0023390
b - 24 mm (0.94 in) - -
PN25/40
D - 200 mm (7.87 in) - -
62 Endress+Hauser
Micropilot FMR53, FMR54
Endress+Hauser 63
Micropilot FMR53, FMR54
A B
26 (1.02)
26 (1.02)
46 (1.81)
46 (1.81)
99.5 (3.92)
99.5 (3.92)
L2
L2
ø33 (1.3) ø33 (1.3)
L1
L1
A0023391
64 Endress+Hauser
Micropilot FMR53, FMR54
A B C D
295.6(11.6)
229.6(9.04)
77(3.03)
b
b
b
b
R
L1
L
L
L
78
(3.07)
ød ød ød
øD øD øD
L
ød
øD
A0017809
Dimension BC: Horn BD: Horn BE: Horn BF: Horn BG: Horn
80mm/3" 100mm/4" 150mm/6" 200mm/8" 250mm/10"
L 68 mm (2.68 in) 105 mm 185 mm (7.28 in) 268 mm (10.6 in) 360 mm (14.2 in)
(4.13 in)
L1 100 mm (3.94 in) / 200 mm (7.87 in) / 300 mm (11.8 in) / 400 mm (15.7 in)
b 20 mm 20 mm 22 mm 24 mm 26 mm
(0.79 in) (0.79 in) (0.87 in) (0.94 in) (1.02 in)
PN10/16
D 200 mm 220 mm 285 mm 340 mm 405 mm
(7.87 in) (8.66 in) (11.2 in) (13.4 in) (15.9 in)
b 24 mm 24 mm - - -
(0.94 in) (0.94 in)
PN25/40
D 200 mm 235 mm - - -
(7.87 in) (9.25 in)
1) For flanges with a higher pressure rating than those listed in the product structure please contact Endress
+Hauser.
2) Feature 100 of the product structure
Endress+Hauser 65
Micropilot FMR53, FMR54
b 28.4 mm 31.8 mm - - -
(1.12 in) (1.25 in)
300 lbs
D 209.5 mm 254 mm - - -
(8.25 in) (10 in)
1) For flanges with a higher pressure rating than those listed in the product structure please contact Endress
+Hauser.
2) Feature 100 of the product structure
b 18 mm 18 mm 22 mm 22 mm 24 mm
(0.71 in) (0.71 in) (0.87 in) (0.87 in) (0.94 in)
10 K
D 185 mm 210 mm 280 mm 330 mm 400 mm
(7.28 in) (8.27 in) (11 in) (13 in) (15.7 in)
1) For flanges with a higher pressure rating than those listed in the product structure please contact Endress
+Hauser.
2) Feature 100 of the product structure
66 Endress+Hauser
Micropilot FMR53, FMR54
A B
b
R
94.5 (3.72)
94.5 (3.72)
30(1.18)
30(1.18)
46.5(1.83)
97(3.82)
46.5(1.83)
97(3.82)
ø150(5.91) ø150(5.91)
øE
L1
øe
øE mm (in)
A0017810
Antenna extension
Dimension Feature 070 "Antenna"
b 25.4 mm (1 in) 28.4 mm (1.12 in) 30.2 mm (1.19 in) 31.8 mm (1.25 in)
150 lbs
E 279.4 mm (11 in) 342.9 mm (13.5 in) 406.4 mm (16 in) 482.6 mm (19 in)
Endress+Hauser 67
Micropilot FMR53, FMR54
Weight Housing
Part Weight
68 Endress+Hauser
Micropilot FMR53, FMR54
5.2
6
5.1
7
4 3 9 8
A0013788
5.1 Dummy plug, cable gland, adapter or plug • Dummy plug, depending on the device version:
(depending on the device version) – PE
– PBT-GF
• Cable gland: 316L (1.4404) or nickel-plated brass
• Adapter: 316L (1.4404/1.4435)
• Seal: EPDM
• M12 plug: Nickel-plated brass 1)
• 7/8" plug: 316 (1.4401) 2)
5.2 Dummy plug, cable gland or adapter (depending on • Dummy plug: 316L (1.4404)
the device version) • Cable gland: 316L (1.4404) or nickel-plated brass
• Adapter: 316L (1.4404/1.4435)
• Seal: EPDM
6 Dummy plug or M12 socket (depending on the • Dummy plug: 316L (1.4404)
device version) • M12 socket: 316L (1.4404)
1) For the version with M12 plug the sealing material is Viton.
2) For the version with 7/8" plug, the sealing material is NBR.
Endress+Hauser 69
Micropilot FMR53, FMR54
5.2
6
5.1
7
4 3 9 8
A0013788
1 Housing PBT
5.1 Dummy plug, cable gland, adapter or plug • Dummy plug, depending on the device version:
(depending on the device version) – PE
– PBT-GF
• Cable gland, depending on the device version:
– Nickel-plated brass (CuZn)
– PA
• Adapter: 316L (1.4404/1.4435)
• Seal: EPDM
• M12 plug: Nickel-plated brass 1)
• 7/8" plug: 316 (1.4401) 2)
5.2 Dummy plug, cable gland or adapter (depending on • Dummy plug, depending on the device version:
the device version) – PE
– PBT-GF
– Nickel-plated steel
• Cable gland, depending on the device version:
– Nickel-plated brass (CuZn)
– PA
• Adapter: 316L (1.4404/1.4435)
• Seal: EPDM
6 Dummy plug or M12 socket (depending on the • Dummy plug: Nickel-plated brass (CuZn)
device version) • M12 socket: Nickel-plated GD-Zn
1) For the version with M12 plug the sealing material is Viton.
2) For the version with 7/8" plug, the sealing material is NBR.
70 Endress+Hauser
Micropilot FMR53, FMR54
5.2
6
5.1
7
4 3 9 8
A0013788
2.1 Cover of the electronics compartment; RAL 7035 • Cover: AlSi10Mg(<0,1% Cu)
(gray) • Window: Glass
• Cover seal: NBR
• Seal of the window: NBR
• Thread-coating: Graphite-based lubricant varnish
2.2 Cover of the terminal compartment; RAL 7035 • Cover: AlSi10Mg(<0,1% Cu)
(gray) • Cover seal: NBR
• Thread-coating: Graphite-based lubricant varnish
5.1 Dummy plug, cable gland, adapter or plug • Dummy plug, depending on the device version:
(depending on the device version) – PE
– PBT-GF
• Cable gland, depending on the device version:
– Nickel-plated brass (CuZn)
– PA
• Adapter: 316L (1.4404/1.4435)
• Seal: EPDM
• M12 plug: Nickel-plated brass 1)
• 7/8" plug: 316 (1.4401) 2)
5.2 Dummy plug, cable gland or adapter (depending on • Dummy plug, depending on the device version:
the device version) – PE
– PBT-GF
– Nickel-plated steel
• Cable gland, depending on the device version:
– Nickel-plated brass (CuZn)
– PA
• Adapter: 316L (1.4404/1.4435)
• Seal: EPDM
6 Dummy plug or M12 socket (depending on the • Dummy plug : Nickel-plated brass (CuZn)
device version) • M12 socket: Nickel-plated GD-Zn
Endress+Hauser 71
Micropilot FMR53, FMR54
1) For the version with M12 plug the sealing material is Viton.
2) For the version with 7/8" plug, the sealing material is NBR.
2 3
6 6
A0018954
A Flange version
B Version with threaded connection
PVDF
5 Cladding PTFE
72 Endress+Hauser
Micropilot FMR53, FMR54
A B C
1 1
2 2 2
4
4
A0018956
A Compact version
B Version with antenna extension
C High temperature version
Screw A4
Spring-lock washer A4
Screw A4
Endress+Hauser 73
Micropilot FMR53, FMR54
A B
1 1
2 2
A0018957
Screw A2
74 Endress+Hauser
Micropilot FMR53, FMR54
Materials: Weather
protection cover 1
2
3
7 4
5
6
A0015473
No Part: Material
6 Ground terminal
• Screw: A4
• Spring washer: A4
• Clamp: 316L (1.4404)
• Holder: 316L (1.4404)
7 • Washer: A4
• Cheese head screw: A4-70
Endress+Hauser 75
Micropilot FMR53, FMR54
Operability
Operating concept Operator-oriented menu structure for user-specific tasks
• Commissioning
• Operation
• Diagnostics
• Expert level
Operating languages
• English
• Deutsch
• Français
• Español
• Italiano
• Nederlands
• Portuguesa
• Polski
• русский язык (Russian)
• Svenska
• Türkçe
• 中文 (Chinese)
• 日本語 (Japanese)
• 한국어 (Korean)
• Bahasa Indonesia
• tiếng Việt (Vietnamese)
• čeština (Czech)
Feature 500 of the product structure determines which of these languages is preset on delivery.
A0032219 A0032221
76 Endress+Hauser
Micropilot FMR53, FMR54
Format for displaying measured variables and status variables can be individually configured
Permitted ambient temperature for the display: –20 to +70 °C (–4 to +158 °F)
The readability of the display may be impaired at temperatures outside the temperature
range.
Operating local operation with 3 push buttons (, , external operation via touch control; 3 optical
elements ) keys: , ,
A0013137
2 3 6 8
1 4 5 7
A0013764
Endress+Hauser 77
Micropilot FMR53, FMR54
2 3
PROFIBUS DP
ENDRESS + HAUSER
PROFIBUS PA
T
4 4 4
A0015775
1 Segment coupler
2 Computer with Profiboard/Proficard and operating tool (e.g. FieldCare)
3 PLC (Progrommable Logic Controller)
4 Transmitter
5 Additional functions (valves etc.)
78 Endress+Hauser
Micropilot FMR53, FMR54
IN
BT
FF-HSE
1
FF-H1 SB 2
PS BT
LD 4
3
BT ENDRESS + HAUSER
– +
%
PS
FF-H1
BT
1
2
A0017188
IN Industrial network
SB Safety Barrier
BT Bus Terminator
Endress+Hauser 79
Micropilot FMR53, FMR54
3 –
+
E
2 1
A0014019
1 Service interface (CDI) of the measuring device (= Endress+Hauser Common Data Interface)
2 Commubox FXA291
3 Computer with "FieldCare" operating tool
80 Endress+Hauser
Micropilot FMR53, FMR54
Integration in tank gauging The Endress+Hauser Tank Side Monitor NRF590 provides integrated communications for sites with
system multiple tanks, each with one or more sensors on the tank, such as radar, spot or average
temperature, capacitive probe for water detection and/or pressure sensors. Multiple protocols out of
the Tank Side Monitor guarantee connectivity to nearly any of the existing industry standard tank
gauging protocols. Optional connectivity of analog 4...20 mA sensors, digital I/O and analog output
simplify full tank sensor integration. Use of the proven concept of the intrinsically safe HART bus for
all on-tank sensors yields extremely low wiring costs, while at the same time providing maximum
safety, reliability and data availability.
1 2 3
4 5
8 NXA820
16...253 VAC
A0017982
Endress+Hauser 81
Micropilot FMR53, FMR54
1 1 2
ENDRESS+HAUSER ENDRESS+HAUSER
RN 221N RN 221N
FXN 520
20...45 VDC
-
.
A0011278
The number of instruments which can be connected in mutidrop mode can be calculated by the
"FieldNetCalc" program. A description of this program can be found in Technical Information TI
400F (Multidrop Conncector FXN520). The program is available form your Endress+Hauser
sales organisation or in the internet at: www.de.endress.com/Download (text search =
"Fieldnetcalc").
82 Endress+Hauser
Micropilot FMR53, FMR54
RoHS The measuring system complies with the substance restrictions of the Restriction on Hazardous
Substances Directive 2011/65/EU (RoHS 2).
RCM-Tick marking The supplied product or measuring system meets the ACMA (Australian Communications and Media
Authority) requirements for network integrity, interoperability, performance characteristics as well
as health and safety regulations. Here, especially the regulatory arrangements for electromagnetic
compatibility are met. The products are labelled with the RCM- Tick marking on the name plate.
A0029561
Ex approval • ATEX
• IEC Ex
• CSA
• FM
• NEPSI
• KC
• INMETRO
• TIIS (in preparation)
Additional safety instructions must be observed for applications in hazardous areas. They are
contained in the separate "Safety Instructions" (XA) document, which is included in the scope of
delivery. Reference is made to the XA on the nameplate of the device.
Details on the available certificats as well as the associated XAs can be found in the Associated
documentation chapter in the Safety instructions section: → 101.
Dual seal according to The devices have been designed according to ANSI/ISA 12.27.01 as dual seal devices, allowing the
ANSI/ISA 12.27.01 user to waive the use and save the cost of installing external secondary process seals in the conduit
as required by the process sealing sections of ANSI/NFPA 70 (NEC) and CSA 22.1 (CEC) These
instruments comply with the North-American installation practice and provide a very safe and cost-
saving installation for pressurized applications with hazardous fluids.
Further information can be found in the Safety Instructions (XA) of the relevant devices.
Functional Safety Used for level monitoring (MIN, MAX, range) up to SIL 3 (homogeneous or inhomogeneous
redundancy), independently assessed by TÜV Rhineland as per IEC 61508. Other information see
documentation SD01087F: "Functional Safety Manual".
Sanitary compatibility The PTFE antenna of FMR53 conforms to FDA 21 CFR 177.1550 and USP <88> Class VI.
Endress+Hauser 83
Micropilot FMR53, FMR54
Pressure equipment with Pressure instruments with a flange and threaded boss that do not have a pressurized housing do not
allowable pressure fall within the scope of the Pressure Equipment Directive, irrespective of the maximum allowable
≤ 200 bar (2 900 psi) pressure.
Reasons:
According to Article 2, point 5 of EU Directive 2014/68/EU, pressure accessories are defined as
"devices with an operational function and having pressure-bearing housings".
If a pressure instrument does not have a pressure-bearing housing (no identifiable pressure chamber
of its own), there is no pressure accessory present within the meaning of the Directive.
Note:
A partial examination shall be performed for pressure instruments that are part of safety equipment
for the protection of a pipe or vessel from exceeding allowable limits (equipment with safety
function in accordance with Pressure Equipment Directive 2014/68/EU, Article 2, point 4).
GL ABS LR BV DNV
FMR53 - - - - -
FMR54
Radio standard The devices Micropilot FMR50, FMR51, FMR52, FMR53, FMR54, FMR56 and FMR57 are conform
EN302372-1/2 with the TLPR (Tanks Level Probing Radar) standard EN302372-1/2 and can always be used in
closed tanks or bins. For installation, points a to f in Annex B of EN302372-1 have to be taken into
account.
FCC / Industry Canada This device complies with Part 15 of the FCC rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
Canada CNR-Gen Section 7.1.3
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to
the following two conditions: (1) This device may not interference, and (2) this device must accept
any interference, including interference that may cause undesired operation of the device.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts
de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas
produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique
subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.
[Any] changes or modifications not expressly approved by the party responsible for compliance could
void the user's authority to operate the equipment.
Japanese radio approval The devices FMR50, FMR51, FMR52, FMR54 and FMR57 comply with the Japanese Radio Law,
Article 6, Section 1(1).
CRN approval Some device versions have a CRN approval. Devices are CRN approved if the folowing two conditions
are met:
• The device has a CSA approval (Product structure: Feature 010 "Approval")
• The device has a CRN approved process connection according to the following table.
84 Endress+Hauser
Micropilot FMR53, FMR54
• Process connections without CRN approval are not included in this table.
• Refer to the product structure to see which process connections are available for a specific
device type.
• For some process connections not listed in the product structure a CRN approval is available
on request.
• CRN approved devices are marked with the registration number OF15872.5C on the
nameplate.
For device versions listed in the table below, the maximum allowed pressure is reduced if they
have a CRN approval. For device versions not listed in the table below the pressure range as
indicated in the "Process" chapter → 58 is not affected by the CRN approval.
Track record FMR5x is the upgrade model of the corresponding FMR2xx series.
Endress+Hauser 85
Micropilot FMR53, FMR54
KG 3.1 Material certificate+PMI test (XRF), internal procedure, wetted metallic FMR54
parts, EN10204-3.1 inspection certificate
KR Liquid penetrant test ASME VIII-1 (PT), wetted/pressurized metallic parts, • FMR53
inspection certificate • FMR54
Test reports, declarations and material test certificates can be obtained electronically from the
W@M Device Viewer :
Enter the serial number from the nameplate (www.endress.com/deviceviewer)
This applies to the options of the following ordering features:
• 550 "Calibration"
• 580 "Test, Certificate"
Product documentation on Test reports, declarations and material certificates can be ordered as hardcopies via ordering feature
paper 570 "Service", option I7 „Product documentation on paper“. The printouts will be enclosed in the
product delivery.
86 Endress+Hauser
Micropilot FMR53, FMR54
Endress+Hauser 87
Micropilot FMR53, FMR54
Ordering information
Ordering information Detailed ordering information is available from the following sources:
• In the Product Configurator on the Endress+Hauser website: www.endress.com -> Click "Corporate"
-> Select your country -> Click "Products" -> Select the product using the filters and search field ->
Open product page -> The "Configure" button to the right of the product image opens the Product
Configurator.
• From your Endress+Hauser Sales Center: www.addresses.endress.com
Product Configurator - the tool for individual product configuration
• Up-to-the-minute configuration data
• Depending on the device: Direct input of measuring point-specific information such as
measuring range or operating language
• Automatic verification of exclusion criteria
• Automatic creation of the order code and its breakdown in PDF or Excel output format
• Ability to order directly in the Endress+Hauser Online Shop
88 Endress+Hauser
Micropilot FMR53, FMR54
3-point linearity protocol The following notes must be taken into account if option F3 ("3 point linearity protocol") has
been selected in feature 550 ("Calibration").
The 3 points of the linearity protocol are defined as follows:
R R
500 (19.7)
A
1
6000 (236)
6000 (236)
A
500 (19.7)
1
2
2
3 3
A0023274
2nd measuring point centrally between 1st and 3rd measuring point
3rd measuring point 6 000 mm (236 in) below the reference point, R
Endress+Hauser 89
Micropilot FMR53, FMR54
5-point linearity protocol The following notes must be taken into account if option F4 ("5 point linearity protocol") has
been selected in feature 550 ("Calibration").
The five points of the linearity protocol are evenly distributetd across the measuring range (0% to
100%). In order to define the measuring range, Empty calibration (E) and Full calibration (F) have
to be specified 7).
The following restrictions have to be taken into account when defining E and F:
R R
A
E
E
F
F
A0019161
FMR54 with antenna extension 2) A ≥ antenna length + F ≥ 400 mm (16 in) E ≤ 20 m (66 ft)
antenna extension +
200 mm (8 in) 3)
1) Minimum value for FMR53: 590 mm (23.6 in); Minimum value for FMR54: 400 mm (16 in)
2) Feature 610 "Accessory Mounted", option OM, ON, OR or OS
3) Minimum value: 400 mm (8 in)
The selected values of Empty calibration and Full calibration are only used to record the
linearity protocol and are reset to their probe specific default values thereafter. If values
different from the default are required, they must be ordered as a customized parametrization
→ 91.
7) If E and F are not specified, probe dependent default values will be used instead.
90 Endress+Hauser
Micropilot FMR53, FMR54
Customized parametrization If the option IJ "Customized parametrization HART", IK "Customized parametrization PA" or IL
"Customized parametrization FF" has been selected in feature 570 "Service", customer specific
presettings can be selected for the following parameters:
Setup → Adv. Setup → Current output 1/2 → Failure mode HART • Min
• Max
• Last valid value
Setup → Adv. Setup → Current output 1/2 → Burst mode HART • Off
• On
Services The following services can be selected via the product structure in the Product Configurator 8):
• PWIS free (PWIS: paint wetting impairment substances)
• Customized parametrization HART → 91
• Customized parametrization PA→ 91
• Customized parametrization FF → 91
• Without tooling DVD (FieldCare)
Endress+Hauser 91
Micropilot FMR53, FMR54
Application Packages
Heartbeat Diagnostics Availability
Available in all device versions.
Function
• Continuous self-monitoring of the device.
• Diagnostic messages output to
– the local display.
– an asset management system (e.g. FieldCare/DeviceCare).
– an automation system (e.g. PLC).
Advantages
• Device condition information is available immediately and processed in time.
• The status signals are classified in accordance with VDI/VDE 2650 and NAMUR recommendation
NE 107 and contain information about the cause of the error and remedial action.
Detailed description
See Operating Instructions of the device (→ 101); chapter "Diagnostics and trouble shooting"
92 Endress+Hauser
Micropilot FMR53, FMR54
Advantages
• No onsite presence is required to use the function.
• The DTM 9) triggers verification in the device and interprets the results. No specific knowledge is
required on the part of the user.
• The verification report can be used to prove quality measures to a third party.
• Heartbeat Verification can replace other maintenance tasks (e.g. periodic check) or extend the
test intervals.
• The Heartbeat Verification module contains a wizard for the proof test which must be performed
at appropriate intervals for the following applications:
– SIL (IEC61508/IEC61511)
– WHG (German Water Resources Act)
• To perform a proof test, the device must be locked (SIL/WHG locking).
• The wizard can be used via FieldCare, DeviceCare or a DTM-based process control system.
In the case of SIL-locked and WHG-locked devices, it is not possible to perform verification
without additional measures (e.g. by-passing of the output current) because the output current
must be simulated (Increased safety mode) or the level must be approached manually (Expert
mode) during subsequent re-locking (SIL/WHG locking).
Detailed description
SD01871F
9) DTM: Device Type Manager; controls device operation via DeviceCare, FieldCare or a DTM-based process control system.
10) Only relevant for devices with SIL or WHG approval: order code 590 ("Additional approval"), option LA ("SIL") or LC ("WHG").
Endress+Hauser 93
Micropilot FMR53, FMR54
Function
• In addition to the verification parameters, the corresponding parameter values are also logged.
• Existing measured variables, such as the echo amplitude, are used in the Foam detection and
Build-up detection wizards.
The Foam detection and Build-up detection wizards cannot be used together.
Advantages
• Early detection of changes (trends) to ensure plant availability and product quality.
• Use of information for the proactive planning of measures (e.g. cleaning/maintenance).
• Identification of undesirable process conditions as the basis to optimizing the facility and the
processes.
• Automated control of measures to remove foam or buildup.
Detailed description
SD01871F
94 Endress+Hauser
Micropilot FMR53, FMR54
Accessories
Device-specific accessories Weather protection cover
Accessory Description
4)
65°
35°
(6.1
156
A0015472
The weather protection cover can be ordered together with the device (product structure, feature 620 "Accessory
Enclosed", option PB "Weather Protection Cover").
Alternatively, it can be separately ordered as an accessory; order code 71162242.
Endress+Hauser 95
Micropilot FMR53, FMR54
Accessory Description
Antenna extension
FAR10 (for FMR54)
ø78 (ø3.07)
ø44.5 (ø1.75)
ø62 (ø2.44)
ø40 (ø1.57)
1 L1 2 mm (in)
A0018879
1 Instrument connection
2 Horn connection
Material:
• 316L (1.4404)
• Alloy B2
• Alloy C4
Length L1:
• 100 mm (4 in)
• 200 mm (8 in)
• 300 mm (12 in)
• 400 mm (16 in)
Detailed ordering information is available from the following sources:
• In the Product Configurator on the Endress+Hauser website: www.endress.com → Select country → Instruments →
Select device → Product page function: Configure this product
• From your Endress+Hauser Sales Center: www.endress.com/worldwide
96 Endress+Hauser
Micropilot FMR53, FMR54
Accessories Description
2.
1.
4.
3.
A0019128
• Material:
– Plastic PBT
– 316L/1.4404
• Degree of protection: IP68 / NEMA 6P and IP66 / NEMA 4x
• Suitable for display modules:
– SD02 (push buttons)
– SD03 (touch control)
• Connecting cable:
– Cable supplied with device up to 30 m (98 ft)
– Standard cable supplied by customer up to 60 m (196 ft)
• Ambient temperature range: –40 to 80 °C (–40 to 176 °F)
• Ambient temperature range (option): –50 to 80 °C (–58 to 176 °F) 1)
• IfL ortheM).remote display should be used, order the device version "Prepared for display FHX50" (feature 030, version
For the FHX50, you must select option A: "Prepared for display FHX50" under feature 050 "Measuring
device version".
• If the device version "Prepared for display FHX50" was not originally ordered and a FHX50 display is to be
retrofitted, you must select version B "Not prepared for display FHX50" under feature 050: "Measuring device
version" when ordering the FHX50. In this case, a retrofit kit for the device is supplied with the FHX50. The kit
can be used to prepare the device so that the FHX50 can be used.
Use of the FHX50 may be restricted for transmitters with an approval. A device can only be retrofitted with the
FHX50 if the option L or M ("Prepared for FHX50") is listed under Basic specifications, item 4 "Display, operation" in
the Safety Instructions (XA) for the device.
Also pay attention to the Safety Instructions (XA) of the FHX50.
Endress+Hauser 97
Micropilot FMR53, FMR54
Overvoltage protection
Accessory Description
A0021734
Technical data
• Resistance per channel: 2 * 0.5 Ωmax
• Threshold DC voltage: 400 to 700 V
• Threshold impulse voltage: < 800 V
• Capacitance at 1 MHz: < 1.5 pF
• Nominal arrest impulse voltage (8/20 μs): 10 kA
• Suited for wire cross-sections: 0.2 to 2.5 mm2 (24 to 14 AWG)
Gas-tight feedthrough
Accessory Description
Gas-tight feedthrough Chemically inert glass feedthrough; prevents migration of gases into the electronics housing.
To be ordered with the device: product structure, feature 610 "Accessory Mounted", option NC "Gas-tight feedthrough"
98 Endress+Hauser
Micropilot FMR53, FMR54
Accessory Description
Commubox FXA291 Connects Endress+Hauser field devices with CDI interface (= Endress+Hauser
Common Data Interface) to the USB interface of a computer.
Order code: 51516983
Accessory Description
HART Loop Converter Evaluates the dynamic HART variables and converts them to analog current signals
HMX50 or limit values.
Order code: 71063562
Accessory Description
Accessory Description
Fieldgate FXA320 Gateway for remote monitoring of connected 4-20mA measuring devices via web
browser.
Accessory Description
Fieldgate FXA520 Gateway for remote diagnosis and parametrization of connected HART measuring
devices via web browser.
Accessory Description
Field Xpert SFX350 Field Xpert SFX350 is a mobile computer for commissioning and maintenance. It
enables efficient device configuration and diagnostics for HART and FOUNDATION
fieldbus devices in the non-Ex area.
Endress+Hauser 99
Micropilot FMR53, FMR54
Accessory Description
Field Xpert SFX370 Field Xpert SFX370 is a mobile computer for commissioning and maintenance. It
enables efficient device configuration and diagnostics for HART and FOUNDATION
fieldbus devices in the non-Ex area and the Ex area.
Graphic Data Manager The graphic data manager Memograph M provides information on all the relevant
Memograph M process variables. Measured values are recorded correctly, limit values are
monitored and measuring points analyzed. The data are stored in the 256 MB
internal memory and also on an SD card or USB stick.
RN221N Active barrier with power supply for safe separation of 4 to 20 mA current circuits.
Provides bi-directional HART transmission.
RNS221 Transmitter supply for 2-wire sensors or transmitters exclusively for non-Ex areas.
Provides bi-directional communication using the HART communication sockets.
100 Endress+Hauser
Micropilot FMR53, FMR54
Documentation
The following document types are available:
In the Download Area of the Endress+Hauser Internet site: www.endress.com → Download
Safety Instructions (XA) Depending on the approval, the following Safety Instructions (XA) are supplied with the device. They
are an integral part of the Operating Instructions.
BB ATEX: II 1/2 G Ex ia IIC T6-T1 Ga/Gb • FMR53 XA00677F XA00677F XA00677F XA00685F -
• FMR54
BC ATEX: II 1/2 G Ex d [ia] IIC T6-T1 Ga/Gb • FMR53 XA00680F XA00680F XA00680F XA00688F XA00680F
• FMR54
BD ATEX: II 1/2/3 G Ex ic [ia Ga] IIC T6-T1 • FMR53 XA00678F XA00678F XA00678F XA00686F XA00678F
Ga/Gb/Gc • FMR54
Endress+Hauser 101
Micropilot FMR53, FMR54
BL ATEX: II 1/2/3 G Ex nA [ia Ga] IIC T6-T1 • FMR53 XA00678F XA00678F XA00678F XA00686F XA00678F
Ga/Gb/Gc • FMR54
B2 ATEX: II 1/2 G Ex ia IIC T6-T1 Ga/Gb • FMR53 XA00683F XA00683F XA00683F XA00691F -
ATEX: II 1/2 D Ex ia IIIC Txx°C Da/Db • FMR54
B3 ATEX: II 1/2 G Ex d [ia] IIC T6-T1 Ga/Gb • FMR53 XA00684F XA00684F XA00684F XA00692F XA00684F
ATEX: II 1/2 D Ex ta IIIC Txx°C Da/Db • FMR54
B4 ATEX:II 1/2 G Ex ia IIC T6-T1 Ga/Gb • FMR53 XA00681F XA00681F XA00681F XA00689F -
ATEX: II 1/2 G Ex d [ia] IIC T6-T1 Ga/Gb • FMR54
CB CSA C/US XP Cl.I Div.1 Gr.A-D FMR54 XA01112F XA01112F XA01112F XA01114F -
CC CSA C/US XP Cl.I Div.1 Gr.A-D FMR54 XA01113F XA01113F XA01113F XA01115F XA01113F
C2 CSA C/US IS Cl.I,II,III Div.1 Gr.A-G, NI Cl.1 Div. • FMR53 XA01112F XA01112F XA01112F XA01114F -
2, Ex ia • FMR54
C3 CSA C/US XP Cl.I,II,III Div.1 Gr.A-G, NI Cl.1 • FMR53 XA01113F XA01113F XA01113F XA01115F XA01113F
Div.2, Ex d • FMR54
FB FM IS Cl.I,II,III Div.1 Gr.A-G, AEx ia, NI Cl.1 • FMR53 XA01116F XA01116F XA01116F XA01118F -
Div.2 • FMR54
FD FM XP Cl.I,II,III Div.1 Gr.A-G, AEx d, NI Cl.1 • FMR53 XA01117F XA01117F XA01117F XA01119F XA01117F
Div.2 • FMR54
IC IECEx: Ex d [ia] IIC T6-T1 Ga/Gb • FMR53 XA00680F XA00680F XA00680F XA00688F XA00680F
• FMR54
ID IECEx: Ex ic [ia Ga] IIC T6-T1 Ga/Gb/Gc • FMR53 XA00678F XA00678F XA00678F XA00686F XA00678F
• FMR54
IL IECEx: Ex nA [ia Ga] IIC T6-T1 Ga/Gb/Gc • FMR53 XA00678F XA00678F XA00678F XA00686F XA00678F
• FMR54
I3 IECEx: Ex d [ia] IIC T6-T1 Ga/Gb • FMR53 XA00684F XA00684F XA00684F XA00692F XA00684F
IEXEx: Ex ta IIIC Txx°C Da/Db • FMR54
102 Endress+Hauser
Micropilot FMR53, FMR54
MC INMETRO: Ex d[ia] IIC T6 Ga/Gb • FMR53 XA01292F XA01292F XA01293F XA01298F XA01294F
• FMR54
NC NEPSI Ex d[ia] IIC T6 Ga/Gb • FMR53 XA01202F XA01202F XA01202F XA01211F XA01202F
• FMR54
N2 NEPSI Ex ia IIC T6 Ga/Gb, Ex iaD 20/21 T85… • FMR53 XA01205F XA01205F XA01205F XA01214F -
90oC • FMR54
N3 NEPSI Ex d[ia] IIC T6 Ga/Gb, DIP A20/21 • FMR53 XA01206F XA01206F XA01206F XA01215F XA01206F
T85…90oC IP66 • FMR54
8A FM/CSA IS+XP Cl.I,II,III Div.1 Gr.A-G • FMR53 • XA01112F • XA01112F • XA01112F • XA01114F -
• FMR54 • XA01113F • XA01113F • XA01113F • XA01115F
• XA01116F • XA01116F • XA01116F • XA01118F
• XA01117F • XA01117F • XA01117F • XA01119F
For certified devices the relevant Safety Instructions (XA) are indicated on the nameplate.
If the device is prepared for the remote display FHX50 (product structure: feature 030: Display,
Operation", option L or M), the Ex marking of some certificates changes according to the following
table 11):
11) The marking of certificates not mentioned in this table are not affected by the FHX50.
Endress+Hauser 103
Micropilot FMR53, FMR54
N3 L or M NEPSI Ex d [ia] IIC T6-T1 Ga/Gb, DIP A20/21 [ia D] TA, Txx°C
IP6X
104 Endress+Hauser
Micropilot FMR53, FMR54
Registered trademarks
HART®
Registered trademark of the FieldComm Group, Austin, USA
PROFIBUS®
Registered trademark of the PROFIBUS User Organization, Karlsruhe, Germany
FOUNDATIONTM Fieldbus
Registered trademark of the FieldComm Group, Austin, Texas, USA
KALREZ®, VITON®
Registered trademark of DuPont Performance Elastomers L.L.C., Wilmington, USA
TEFLON®
Registered trademark of E.I. DuPont de Nemours & Co., Wilmington, USA
TRI CLAMP®
Registered trademark of Alfa Laval Inc., Kenosha, USA
Patents
This product may be protected by at least one of the following patents.
Further patents are pending.
US Patents EP Patents
6.140.940 -
- 882 955
6.606.904 -
6.640.628 -
- 1 389 337
6.779.397 -
7.201.050 -
7.412.337 -
7.552.634 -
7.730.760 -
7.819.002 -
- 1 774 616
7.966.141 -
8.040.274 -
8.049.371 -
Endress+Hauser 105
*71344171*
71344171
www.addresses.endress.com