Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                
Download as pdf or txt
Download as pdf or txt
You are on page 1of 6

All-Metal Variable Area

Flowmeter and Counter


for liquids and gases

BGN

OOMeasuring range:
0.5 - 5.0 ... 13 000 - 130 000 l/h water
0.015 - 0.15 ... 240 - 2 400 m³/h air
(20 °C, 1.013 bar)
OO Accuracy class: 1.6
OO pmax: PN 40; tmax: -40 ... +350 °C
OO Connection: flange DN 15 ... DN150
OO  aterial: stainless steel
M
1.4404/1.4571, Hastelloy® C, PTFE
OO  ption: contacts, analogue output
O
with HART®, Profibus® PA or
Fieldbus® Foundation™, counter

Special
versions up to
600 bar
O
Nominal
diameter up to
DN 150

base@basesistemas.com
976 587 019
https://basesistemas.com/kobold-elementos-de-instrumentacion-y-control-industrial/
All-Metal Variable Area Flowmeter and Counter Model BGN

Technical Details
Fitting
Wetted parts: st. st. 1.4404 (316 L) /
1.4571 (316 Ti),
Hastelloy® C-22/C4, PTFE
other materials on request
Process connection: Flanges acc. EN 1092-1
ASME B16.5, DIN 2512,
JIS, NPT, screw pipe
connection,
special connections on request
Nominal pressure: PN 40, ASME Cl150 / 300
(standard) (BGN-S/H)
Functions PN 16, ASME Cl150
(standard) (BGN-P)
The fluid flows from bottom to top through the meter tube of
the flowmeter. The float is lifted until an annular gap between higher pressure rates optional
the meter ring and the cone-shaped float is produced (max. 600 bar)
which corresponds to the flow. The forces acting on the
float are in equilibrium. The forces that are mainly acting on Process temperature: -40 °C ... +200 °C
the float comprise buoyancy according to the principle of (BGN-S/H without electr. output)
Archimedes, the flow force of the medium and the weight -40 °C ... +150 °C
force. Each position of the float corresponds to a flow value (BGN-S/H with electr. output)
measured during calibration, which is transferred to a scale. -40°C ... +350 °C
The BGN variable area flowmeter consists of a meter tube (BGN-S/H with option V/ H / W)
with connections, a meter ring, and a conical float. By
-40 °C ... +125 °C (BGN-P)
means of a magnet, the position of the float is transferred to
an encapsulated follow magnet, which has been fitted to a Ambient temperature: -40 °C  ... +80°C
pointer axle. The position of a second annular follow magnet
fitted on the pointer axle is transferred to the scale by means
Accuracy
of the pointer.
Liquid: ± 1.6 % of full scale (BGN-S/H)
Application ± 2.0 % of full scale (BGN-P)
The KOBOLD-BGN meter is suitable for flow measurement of Gas: ± 1.8 % of full scale (BGN-S/H)
liquid or gaseous products in pipes. It shows the current flow ± 2.2 % of full scale (BGN-P)
rate in volume or mass per unit in time. Additional inaccuracy
through transmitter (ES): ± 0.2 %
Applications Repeatability: ± 0.5 % of full scale
Flow measurement, monitoring, adjusting and control of liquid Protection: IP 65 (aluminium housing)
and gaseous products. The meter’s design makes it ideal for IP 67 (stainless steel housing)
processes under difficult and rough operating conditions. The
devices are available with additional electrical equipment for
process monitoring and control. Certification
Explosion protection: BVS 03 ATEX H/B 112
OO A large spectrum of wetted materials CE-Marking: Pressure Equipment Directive
97/23/Eg
OO Magneto-resistive signal transmission
OO Gas- or liquid damping (option)
OO Special design for high-pressure and high-temperature
applications
OO Excellent heat tracing technology (option)
OO Double eddy current damping (special version)
OO Self draining (special version)
OO Backflow stop (special version)
OO Flow Controller (special version)

base@basesistemas.com
976 587 019
https://basesistemas.com/kobold-elementos-de-instrumentacion-y-control-industrial/
All-Metal Variable Area Flowmeter and Counter Model BGN

Technical Details (continued)


Display Additional options and special versions:
Material: aluminium (stove-enamelled) • Other materials
stainless steel (as option) • Other flange versions and sizes
Electrical outputs: Inductive switch, • Certifications
SJ 3,5-N NAMUR (standard)*
• Display with pressure compensations
Inductive switch, against condensate build up
SJ 3,5-SN NAMUR (safety
• Microswitch
design)* on request
• Inductive switches with safety design
Microswitch*
• Double eddy current damping
others on request
• Self draining body
Ambient temperature: -40 °C ... +80 °C
(without limit switch) • Backflow stop
-40 °C ... +65 °C • Flow controller
(with limit switch) • Special float for low pressure loss
* Using the segments of the slot-type initiators or the eccentric discs of the
microswitches, any switching point between 10 % and 90 % of the flow rate
can be set.

Transmitter
• ES with HART®-protocol
• ES with HART®-protocol and
2 NAMUR-switches*
• ES with HART®-protocol and
1 NAMUR-switch* / 1 pulse output
• ES with Profibus® PA
• ES with HART®-protocol and counter module
• ES with Fieldbus® Foundation™
* Contact can be configured using HART®

Power supply: 14 - 30 VDC


Output: passive, galvanically isolated
Current: 4-20 mA
Binary 1 and 2: Ui = 30 V, Ii = 20 mA, Pi = 100 mW
Input Binary: Counter reset
(only for ES with counter module)
Ambient temperature: -40 °C ... +70 °C

Certification
Explosion protection: DMT 00 ATEX E 075
Type of protection: II 2G EEx ia IIC T6
CE-Marking: Explosion Protection Directive
94/9/EG

base@basesistemas.com
976 587 019
https://basesistemas.com/kobold-elementos-de-instrumentacion-y-control-industrial/
All-Metal Variable Area Flowmeter and Counter Model BGN

Order Details for Liquids (Example: BGN-S 10 305B A 0 0 0 0 S 1 0 0K)


Model Measuring Measuring Connection Pressure Max. Code2) Code2)
range range air at 20°C, size stage pressure flange flange
[l/h] 1013 mbar (DIN-flange) loss DIN EN1092-1 ASME
[Nm3/h] [mbar] Form B1 Class 150 RF
0.5 - 5 (0.7 - 7)1) 4) 0.015 - 0.15 DN 15, (¾") PN 40 40 10 305B A 10 202R A
1 - 10 (1.2 - 12)1) 4) 0.03 - 0.3 DN 15, (¾") PN 40 44 10 305B B 10 202R B
1.6 - 16 (2 - 20)1) 4) 0.145 - 0.48 DN 15, (¾") PN 40 40 10 305B C 10 202R C
2.5 - 253) 4) 0.075 - 0.75 DN 15, (¾") PN 40 40 10 305B D 10 202R D
4 - 403) 4) 0.13 - 1.3 DN 15, (¾") PN 40 40 10 305B E 10 202R E
5 - 50 0.15 - 1.5 DN 15, (¾") PN 40 40 15 305B F 15 202R F
7 - 70 0.2 - 2.1 DN 15, (¾") PN 40 40 15 305B G 15 202R G
10 - 100 0.3 - 3.0 DN 15, (¾") PN 40 60 15 305B H 15 202R H
16 - 160 0.5 - 4.6 DN 15, (¾") PN 40 60 15 305B I 15 202R I
25 - 250 0.7 - 7.0 DN 15, (¾") PN 40 60 15 305B J 15 202R J
40 - 400 1.0 - 11 DN 15, (¾") PN 40 70 15 305B K 15 202R K
60 - 600 1.7 - 17 DN 15, (¾") PN 40 80 15 305B L 15 202R L
0.5 - 5 (0.7 - 7)1) 4) 0.015 - 0.151) 4) DN 25, 1" PN 40 40 10 309B A 10 203R A
1 - 10 (1.2 - 12)1) 4) 0.03 - 0.31) 4) DN 25, 1" PN 40 44 10 309B B 10 203R B
1.6 - 16 (2 - 20)1) 4) 0.145 - 0.481) 4) DN 25, 1" PN 40 40 10 309B C 10 203R C
2.5 - 253) 4) 0.075 - 0.753) 4) DN 25, 1" PN 40 40 10 309B D 10 203R D
4 - 403) 4) 0.13 - 1.33) 4) DN 25, 1" PN 40 40 10 309B E 10 203R E
5 - 50 0.15 - 1.5 DN 25, 1" PN 40 40 15 309B F 15 203R F
BGN-S =
stainless 7 - 70 0.2 - 2.1 DN 25, 1" PN 40 40 15 309B G 15 203R G
steel 10 - 100 0.3 - 3.0 DN 25, 1" PN 40 60 15 309B H 15 203R H
measuring 16 - 160 0.5 - 4.6 DN 25, 1" PN 40 60 15 309B I 15 203R I
tube 25 - 250 0.7 - 7.0 DN 25, 1" PN 40 60 15 309B J 15 203R J
40 - 400 1.0 - 11 DN 25, 1" PN 40 70 15 309B K 15 203R K
BGN-P = 60 - 600
   
1.7 - 17 DN 25, 1" PN 40 80 15 309B L 15 203R L
stainless 100 - 1000 3 - 30 DN 25, 1" PN 40 60 25 309B M 25 203R M
steel 160 - 1600 4 - 46 DN 25, 1" PN 40 70 25 309B N 25 203R N
measuring
250 - 2500 7 - 70 DN 25, 1" PN 40 100 25 309B P 25 203R P
tube, PTFE-
lining 400 - 40003) 8) 11 - 1103) 8) DN 25, 1" PN 40 240 25 309B Q 25 203R Q
250 - 2500 7 - 70 DN 40, 1 ½" PN 40 50 40 317B P 40 205R P
400 - 4000 11 - 110 DN 40, 1 ½" PN 40 120 40 317B Q 40 205R Q
BGN-H = 600 - 6000 17 - 170 DN 40, 1 ½" PN 40 180 40 317B R 40 205R R
Hastelloy® 400 - 4000 11 - 110 DN 50, 2" PN 40 80 50 321B Q 50 206R Q
measuring
600 - 6000 17 - 170 DN 50, 2" PN 40 90 50 321B R 50 206R R
tube
1000 - 10 000 29 - 290 DN 50, 2" PN 40 110 50 321B S 50 206R S
1600 - 16 000 46 - 460 DN 50, 2" PN 40 230 50 321B T 50 206R T
2500 - 25 0003) 8) 70 - 7003) 8) DN 50, 2" PN 40 500 50 321B U 50 206R U
1600 - 16 000 46 - 460 DN 80, 3" PN 40 70 80 331B T 80 208R T
2500 - 25 000 70 - 700 DN 80, 3" PN 40 100 80 331B U 80 208R U
4000 - 40 0003) 110 - 1100 DN 80, 3" PN 40 350 80 331B V 80 208R V
4000 - 40 000 110 - 1100 DN 100, 4" PN 16 120 1H 335B V 1H 210R V
6000 - 60 0003)
170 - 1700 DN 100, 4" PN 16 360 1H 335B W 1H 210R W
(5500 - 55 000)1)
8000 - 80 0003) 240 - 24003) DN 100, 4" PN 16 600 1H 335B X 1H 210R X
10 000 -100 0003) 7) - DN 100, 4" PN 16 on request 1H 335B 2 1H 210R 2
4000 - 40 000 on request DN 125, 5" PN 16 on request 1H 340B V 1H 211R V
6000 - 60 0003)
on request DN 125, 5" PN 16 on request 1H 340B W 1H 211R W
(5500 - 55 000)1)
8000 - 80 0003) on request DN 125, 5" PN 16 on request 1H 340B X 1H 211R X
10 000 -100 0003) 7) on request DN 125, 5" PN 16 on request 1H 340B 2 1H 211R 2
10 000 -100 0003) 10) on request DN 150, 6" PN 16 on request H5 345B 2 H5 212R 2
13 000 -130 0003) 10) on request DN 150, 6" PN 16 on request H5 345B 4 H5 212R 4

base@basesistemas.com
976 587 019
https://basesistemas.com/kobold-elementos-de-instrumentacion-y-control-industrial/
All-Metal Variable Area Flowmeter and Counter Model BGN

Continuation Order Details for Liquids (Example: BGN-S 10 305B A 0 0 0 0 S 1 0 0K)


Heating3) / Damping3) / Draining Certificates Display Scale Electrical Accesso-
cooling spring stop body output ries

0 = without
1 = 1 inductive limit
switch, SIL-19)
2 = 2 inductive limit
switches,
SIL-19)
C = 1 micro switch
0 = without S = aluminium
certificate D = 2 micro swit-
V = a
 luminium, ches
1 = certificate assembled
of compli- at distance 6 = transmitter ES
0 = without ance with with HART®,
up to 350 °C Water
R = with flow the order EEx ia, 4-20
2.1 E = stainless 1 = %-scale mA, SIL-19)
restrictor
0 = without steel
for gas 2 = certificate 2 = measu- 7 = transmitter ES
1 = with heating measuring5) of compli- H = stainless ring range with HART®,
Ermeto 12 ance with steel, as- EEx ia,4-20 mA
F = with liquid Media
mm 0 = without the order sembled at and 2 NAMUR- 0K = without
damping
2.2 distance up4 = %-scale switches,
2 = with heating L = with self XK = special
G = with gas to 350 °C SIL-19)
DIN-flange draining B = inspec- 5 = measu- (separate
damping
DN15/PN 40 body tion certi- T = aluminium ring range 8 = transmitter ES specification)
A = with spring ficate with with pressure with HART®,
3 = with heating Please
stop material compensati- EEx ia,4-20 mA,
ANSI-flange specify media
certificate on 1 NAMUR-
½" Class 150 S = with gas data in
damping 3.1 W = aluminium switch and 1
plain text (see
and spring with pressure pulse output,
C = inspec- below)
stop6) compen- SIL-19)
tion certi-
ficate with sation, 9 = electrical
material assembled transmitter ES
certificate at distance with Profibus®
3.2 up to 350 °C PA, EEx ia
I = 4-20 mA with
HART® and
counter module
K = electrical
transmitter ES
with Fieldbus®
Foundation™

Reference conditions: water at 20 °C, 1 mPas For the right design of the flowmeter we need the following data:
1)
Different measuring range for model BGN-P (PTFE-chasing) measuring range with unit, measured media, process temperature
2)
Other flange connections: Form B1, N, D, JIS or Class 300 on request and pressure, viscosity, operating density (liquids), norm density
3)
Not for model BGN-P (PTFE-casing)
(gases), mechanical connections
4)
Not for model BGN-H (Hastelloy®)
5)
Only up to measuring range: 40 l/h
6)
Only for nominal diameter DN 100
7)
Damping not possible
8)
Not available with heating / cooling
9)
IEC 61508-2:2010 Conformity confirmed by EXIDA
10)
Option display only available in »V«, »H« and »W«

base@basesistemas.com
976 587 019
https://basesistemas.com/kobold-elementos-de-instrumentacion-y-control-industrial/
All-Metal Variable Area Flowmeter and Counter Model BGN

250

155
Dimensions [mm]
155
Display: aluminium

145*
A 70

153
250
250

155

47,4
Ø 19 6
250
155 Øl.W.

145*
70
Display: stainless steel 158*

81
A
153
250

153
47,4
Ø 19 6
250

250

68

Øl.W.

Øl.W.

158*

DN PN 81 I. W. (inner width) A (aluminium) A (st. steel)


15 40 26 74 100
25 40 32 77 103
40 40 46 85 110
50 40 70 98 123
153

80 40 102 14 140
100 16 125 127 153
250

125 16 150 142 166


150 16 159 148 171
68

Dimensional deviations:
* +100 mm with forward advanced display and generally at DN 125 and DN 150

base@basesistemas.com
976 587 019
https://basesistemas.com/kobold-elementos-de-instrumentacion-y-control-industrial/