Lambda Vega
Lambda Vega
• Up to 11 outputs
• Voltages up to 62V, Current up to 114 Amps
• Screw, Fast-on or IEC connection
• Worldwide approvals & CB report
• Medical Approval Option
• 3 Year Warranty
Vega Series
Medical ATE
Automation Industrial Computing
450, 650 & 900 Watts Security Lifesciences/Laboratory
Modular Power Solution Network Servers and Routers
INPUT
Vega 450, 650, and 900 Vega dc (450W)
Input Voltage 90 - 264Vac 34 - 75Vdc
900W version is 150-264Vac only, 650W below 150Vac Derate linearly below 44V to 340W at 34V
Input Frequency 47 - 63Hz (440Hz with reduced PFC - consult factory) dc only
Inrush Current <40A at 25°C and 264Vac (cold start) <40A at 25°C, ETSI EN300 132-2
Input Fuse 16A / 250Vac HBC Fast Acting (not user accessible) 20A Fast Acting (not user accessible)
Leakage Current 1.5mA max at 264Vac & 63Hz n/a
Lower Leakage Option see configuring guide n/a
Power Factor 0.99 typical n/a
OUTPUT
Voltage / Current See module output table
Turn on Delay 1.5s max at 90Vac (150Vac for 900W, 48Vdc for Vega dc) & 100% rated output power
Rise Time <50ms to 90% of voltage, monotonic rise above 10%
Turn on Overshoot <5% or 250mV Load type dependant, no overshoot with resistive load
Efficiency 75% typical at 230Vac (48Vdc for Vega dc) & 100% rated power, config dependent
Hold up 16ms min at 90Vac (150Vac for 900W) & 100% rated output power. 10ms min for Vega dc
Ripple & Noise <1% or 50mV Pk- Pk, using EIAJ test method & 20MHz bandwidth
Voltage Accuracy <1% of set Voltage
Standard on single output modules, max 0.75V total line drop
Remote Sense Yes
Option for twin output modules
Minimum Load No on any output
Temperature Coefficient <0.02% of rated voltage per °C
Load Regulation <0.5% or 25mV for 0-100% load change
Line Regulation <0.1% for 90 - 264Vac input change (34-75Vdc for Vega dc)
Cross Regulation <0.2% for 100% load change on any other output
<6% or 300mV of set voltage for 50% load change (above 25% load)
Transient Response Recovery
500µs for recovery to 1% or 100mV of set voltage
120 - 130% of set voltage for outputs > 4.1V (Tracking OVP)
Over Voltage Protection 140 - 150% of set voltage for outputs < 4.1V (Tracking OVP)
120 - 150% of max rated output (Fixed OVP)
Over Current Protection 105 - 125% of rated current, constant current characteristic
Vega Series 1
SAFETY APPROVALS
ENVIRONMENT
Temperature 0° to 65° operational, -40° to 70°C storage (max 12 months)
Derating 50°C to 65°C derate each output by 2.5% per °C
Low Temperature Start-up -20°C
Humidity 5-95% RH non condensing
±3 x 20g shocks in each plane, total 18 shocks
20g shock = 11ms (±0.5ms), half sine
Shock
conforms to EN60068-2-27, EN60068-2-47, IEC68-2-27, IEC68-2-47, JIS C0041-1987
conforms to MIL-STD-810E/F, Method 516.5, Pro I, IV, VI
Single axis 10 - 500Hz at 2g (sweep and endurance at resonance) in all 3 planes
Vibration Conforms to EN60068-2-6, IEC68-2-6
Conforms to MIL-STD-810E, Method 514.4, Pro I, Cat 1, 9
Altitude 5000 metres operational / non operational (IEC inlet 3000m operational, 5000m non-operational)
Pollution Degree 2, Material group 3
IP Rating IP 10
ISOLATION
Input to Output Reinforced 4kV (ac), 5.7kV (dc) type tested, production tested to 4.3kVdc. Vega dc = 4.3kVdc
Input to Earth Basic 2.3 kV (dc) Output to Output / Output to Earth Operational 200 V (dc)
2 Vega Series
OUTPUT VOLTAGES (single output modules) (twin output modules)
Adjustment Range V1 Adjustment V2 Adjustment
Module Amps Slots Module Amps Amps Slots
(Volts) Range (Volts) Range (Volts)
B1L 1.8 - 3.8e 20 1 H1L/1L 1.8 - 3.8n 8 1
C1 1.8 - 4.1e 35 1 H1L/1H 3.9 - 5.5d 8 1
C1Y 1.8 - 4.1e 40 1 H1L/2 1.8 - 3.8n 12 5.6 - 9f 6 1
D1L 1.8 - 3.8 50 1.5 H1L/3 9.1 - 16.2u 6 1
E1 1.8 - 3.8e 60 2 H1L/4 16.3 - 25p 4.5 1
F1a 1.8 - 3.8 80 2 H1H/1L 1.8 - 3.8n 8 1
Z2 1.8 - 3.8e 95 3 H1H/1H 3.9 - 5.5d 8 1
Z3 1.8 - 3.8e 114 4 H1H/2 3.9 - 5.5d 12 5.6 - 9f 6 1
B1H 3.9 - 5.5d 20 1 H1H/3 9.1 - 16.2u 6 1
L1 4.2 - 5.5d 35 1 H1H/4 16.3 - 25p 4.5 1
D2 3.8 - 9k 45 1.5 H2/1L 1.8 - 3.8n 8 1
D1H 3.9 - 5.5d 50 1.5 H2/1H 3.9 - 5.5d 8 1
E2 3.8 - 8k 60 2 H2/2 5.6 - 9f 10 5.6 - 9f 6 1
Z18 4.2 - 5.5 66 2 H2/3 9.1 - 16.2u 6 1
F2a 3.8 - 8 75 2 H2/4 16.3 - 25p 4.5 1
Z4 3.9 - 5.5d 95 3 H3/1L 1.8 - 3.8n 8 1
Z6 3.9 - 5.5d 104 3.5 H3/1H 3.9 - 5.5d 8 1
B2 5 - 9f 25 1 H3/2 9.1 - 16.2u 10 5.6 - 9f 6 1
B3 9.1 - 16.2g 12 1 H3/3 9.1 - 16.2u 6 1
C3 9.1 - 16.2g 18 1 H3/4 16.3 - 25p 4.5 1
D3 8 - 16.5g 24 1.5 H5/1L 1.8 - 3.8n 8 1
E3L 8 - 13.9l 40 2 H5/1H 3.9 - 5.5d 8 1
Z7 8 - 16.5g 45 3 H5/2 16.2 - 28 5 5.6 - 9f 6 1
EE2 7.6 - 16g 45 4 H5/3 9.1 - 16.2u 6 1
D4 14 - 21.5i 18 1.5 H5/4 16.3 - 25p 4.5 1
E4 14 - 19.9m 30 2 Wide Range Programmable Modules
E3H 14 - 15 36 2 Module Voltage Range Amps Slots
C4 16.3 - 21.5i 14 1 W2a 1 - 7.5 30 1 Select features from table
CC3 18.2 - 32.4j 18 2 W5 0.5 - 32 8.5 1 below
E5Lv 20 - 24 27 2
B5 21.6 - 31h 6 1 Follow by F or T Fixed or Tracking Overvoltage protection
C5 21.6 - 31j 10 1 F or S Fast-on or Screw terminal
D5 21 - 28 15 1.5 Resistance (0-32kOhm)
R or V
E5Hv 24 - 28 25 2 Voltage (0-5V) programming
Z19co 24 - 28 36 3.5 1 Inhibit, Fixed Current Limit
HH5/3 25.3 - 44.2b 5 1 1, 2, 3 2 Inhibit, Programmable current limit (0-5V)
DD4 28 - 43s 18 3 or 4 3 Enable, Fixed Current Limit
EE4c 28 - 38 22.5 4 4 Enable, Programmable current limit (0-5V)
HH5/4 32.5 - 53t 4.5 1
BB4 32.6 - 43q 10 2 Follow non wide range modules by F (Fast-on) or S (Screw) terminal
EE5Lco 40 - 48 18 4 Options - Single output Modules* Options - Twin Output Modules*
C5B4 43 - 48 10 2 Output Inhibit, Module Good,
Output Inhibit, Module Good N
EE5Ho 48 - 56 18 4 N Remote Sense
Current Sharing
CC5 48.1 - 62r 10 2 R Remote sense only
DD5 42 - 56 15 3 * see configuring guide
Vega Series 3
Vega Configuring Guide
The extensive range of output modules and options make it possible to achieve almost any combination of Volts and Amps. The ‘online’ con-
figurator is the best way to achieve the optimum configuration, however you can also create your own Vega configuration from this datasheet
by using the guide below.
Web Configurator
1 Visit http://www.emea.tdk-lambda.com, select ‘Vega Configurator’ and follow the online instructions.
2 Enter your required Volts / Amps, type of output connection and any additional functions (if required)
3 Enter preferred type of cooling, input connection, lower leakage current (if required) and controls & signal functions, (if required)
4 Configurator will select the most suitable modules and options and give a unique part number.
V0 450Wdc
Output V4 450W
Power V6 650W V4 F S S F
V9 900W
F Forward air - Standard
Qd Forward air - Quiet fan
Cooling Ra Reverse air
Pad Reverse air - Quiet fan
Cb Customer air - no fan
S Screw terminal
Input
Fd Fast-on terminal
Connection
Id IEC320 with switch
S Standard 1.5 mA
M 650µA
Leakage (max leakage current at
L 290µA
Current 264Vac, 63Hz)
R 175µA
T 60µA
F ac Fail, Global PSU + fan Inhibit, 5V/100mA standby
FV ac Fail, Global PSU + fan Inhibit, 5V/300mA standby
Controls & xFWcd ac Fail, Global PSU + fan Inhibit, 5-15V/1A standby
Signals E ac Fail, Global PSU + fan Enable, 5V/100mA standby
EV ac Fail, Global PSU + fan Enable, 5V/300mA standby
xEWcd ac Fail, Global PSU + fan Enable, 5-15V/1A standby
Notes:
a) Not available for Vega 900 c) xFW and xEW options increase leakage current by 90µA
b) Thermocoupled sample recommended to ensure ade- Replace ‘x’ with required output voltage (5FW = 5V aux supply)
quate cooling - consult sales d) Not available for Vega dc.
2 Select Output Modules and Options from the Output Voltages tables.
Example - if you require 5.2V / 18A with output inhibit : -
a) select B1H as closest match for voltage and current and prefix with voltage (eg 5.2B1H)
b) add suffix S or F for Screw or Fast-on connection (eg 5.2B1HS)
c) add suffix N for output inhibit eg 5.2B1HSN
d) repeat for other outputs
Ensure you do not select more than a total of 5 slots width of module. This will create a complete product description eg:-
V6FSSF 5L1SN 12/12H3/3S 24C5S which represents a four output 650W Vega with Forward air, Screw input terminals, 1.5mA Earth Leak-
age, ac Fail, Global Inhibit & 5V / 100mA aux supply with the following outputs:-
Output 1 = 5V / 35A with output inhibit, Module Good and Current Share option
Output 2 = 12V / 10A
Output 3 = 12V / 6A
Output 4 = 24V / 10A
4 Vega Series
126.5
15.00
80.50 23.00
7.50 218.00
30.00
31.30
62.80
56.90
31.00
21.00
26.90
22.00
104.30
226.50 M3 countersink
endcap fixings
19.00
All versions have:-
8 x M4 Customer fixings
12.00 268.35 (TO PANEL) Max thread penetration:- 4.5mm
271.35 (TO FRONT OF CONNECTOR)
218.00 126.5
7.50
31.30
Endcap Fixings
62.80
226.50
Customer Air Case (no fan)
19.00
92.00
12.00
.50
249.30
62.80
31.00
22.00
7.60
65.60 19.37
226.50
126.5
45.50
92.00
62.80
31.00
18.35
65.60
270.65 (INCLUDING FAN GRILLE)
Vega Series 5
TDK-LAMBDA EMEA www.emea-tdk-lambda.com
LOCAL DISTRIBUTION
6 Vega Series