389 1996
389 1996
389 1996
Sponsor
Electronics Transformer Technical Committee
of the
IEEE Power Electronics Society
Abstract: A number of tests are presented for use in determining the significant parameters and
performance characteristics of electronics transformers and inductors. These tests are designed
primarily for transformers and inductors used in all types of electronics applications, but they may
apply to the other types of transformers of large apparent-power rating used in the electric power
utility industry.
Keywords: common-mode rejection tests, corona tests, current transformer tests, electronic induc-
tors, electronic power transformers, inductance measurements, inrush-current evaluation, insula-
tion tests, large rectifiers, noise tests, product rating, pulse transformers, quality factor, resistance
tests, self-resonance, temperature rise tests, terminated impedance measurements, transformer
capacitance, voltage-time shielding
ISBN 1-55937-761-5
No part of this publication may be reproduced in any form, in an electronic retrieval system or otherwise, without the prior
written permission of the publisher.
IEEE Standards documents are developed within the IEEE Societies and the Standards Coordinat-
ing Committees of the IEEE Standards Board. Members of the committees serve voluntarily and
without compensation. They are not necessarily members of the Institute. The standards developed
within IEEE represent a consensus of the broad expertise on the subject within the Institute as well
as those activities outside of IEEE that have expressed an interest in participating in the develop-
ment of the standard.
Use of an IEEE Standard is wholly voluntary. The existence of an IEEE Standard does not imply
that there are no other ways to produce, test, measure, purchase, market, or provide other goods and
services related to the scope of the IEEE Standard. Furthermore, the viewpoint expressed at the
time a standard is approved and issued is subject to change brought about through developments in
the state of the art and comments received from users of the standard. Every IEEE Standard is sub-
jected to review at least every five years for revision or reaffirmation. When a document is more
than five years old and has not been reaffirmed, it is reasonable to conclude that its contents,
although still of some value, do not wholly reflect the present state of the art. Users are cautioned to
check to determine that they have the latest edition of any IEEE Standard.
Comments for revision of IEEE Standards are welcome from any interested party, regardless of
membership affiliation with IEEE. Suggestions for changes in documents should be in the form of a
proposed change of text, together with appropriate supporting comments.
Interpretations: Occasionally questions may arise regarding the meaning of portions of standards as
they relate to specific applications. When the need for interpretations is brought to the attention of
IEEE, the Institute will initiate action to prepare appropriate responses. Since IEEE Standards rep-
resent a consensus of all concerned interests, it is important to ensure that any interpretation has
also received the concurrence of a balance of interests. For this reason, IEEE and the members of its
societies and Standards Coordinating Committees are not able to provide an instant response to
interpretation requests except in those cases where the matter has previously received formal
consideration.
Note: Attention is called to the possibility that implementation of this standard may
require use of subject matter covered by patent rights. By publication of this standard,
no position is taken with respect to the existence or validity of any patent rights in
connection therewith. The IEEE shall not be responsible for identifying patents for
which a license may be required by an IEEE standard or for conducting inquiries into
the legal validity or scope of those patents that are brought to its attention.
Authorization to photocopy portions of any individual standard for internal or personal use is
granted by the Institute of Electrical and Electronics Engineers, Inc., provided that the appropriate
fee is paid to Copyright Clearance Center. To arrange for payment of licensing fee, please contact
Copyright Clearance Center, Customer Service, 222 Rosewood Drive, Danvers, MA 01923 USA;
(508) 750-8400. Permission to photocopy portions of any individual standard for educational class-
room use can also be obtained through the Copyright Clearance Center.
Introduction
(This introduction is not part of IEEE Std 389-1996, IEEE Recommended Practice for Testing Electronics Transformers
and Inductors.)
This recommended practice has been prepared to serve as a guide in the design, testing, and specifying of
electronics transformers and inductors. This document contains many tests and experimental methods for
evaluating almost every aspect of electronics transformer performance, including a number of tests for deter-
mining transformer environmental characteristics such as audible-noise generation. The tests and specifica-
tions included are aimed primarily at the testing and evaluation of transformers of relatively low apparent-
power rating, such as those used in communications, instrumentation, control, small appliances, and com-
puter applications. However, most of these tests are perfectly applicable to transformers of any rating. A use-
ful feature of this recommended practice is the listing, in clause 4, of all standard tests used in the
specification of a transformer. This clause will provide a useful starting point for many users of this recom-
mended practice.
MKS units (Standard International or SI units) are used throughout this recommended practice; equivalent
CGS units are sometimes given where their usage is still common practice. Definitions and symbols are in
accordance with those of the International Electrotechnical Commission (IEC) wherever possible.
The Electronics Transformer Technical Committee (ETTC) wishes to acknowledge its indebtedness to those
who have so freely given of their time and knowledge in the development of the original version of this rec-
ommended practice. The fellowship of authors of the inaugural publication, IEEE Std 389-1979, includes
the following distinguished members:
Paul K. Goethe, Chair
This recommended practice was prepared by the Working Group on Transformer Tests of the Test Codes
Subcommittee of the Electronics Transformer Technical Committee of the IEEE Power Electronics Society,
which was comprised of the following membership:
When the Electronics Transformer Technical Committee balloted and approved this recommended practice,
the membership was as follows:
Rohn R. Grant, Chair
iii
When the IEEE Standards Board approved this recommended practice on 20 June 1996, it had the following
membership:
*Member Emeritus
Also included are the following nonvoting IEEE Standards Board liaisons:
Satish K. Aggarwal
Alan H. Cookson
Chester C. Taylor
Valerie E. Zelenty
IEEE Standards Project Editor
iv
Contents
CLAUSE PAGE
1. Overview.............................................................................................................................................. 1
1.1 Scope............................................................................................................................................ 1
1.2 Transformers and inductors ......................................................................................................... 1
2. References............................................................................................................................................ 2
3. Definitions............................................................................................................................................ 3
5.1 General......................................................................................................................................... 3
5.2 Electric strength test (hi-pot test)................................................................................................. 7
5.3 Induced potential test ................................................................................................................... 8
5.4 Corona tests................................................................................................................................ 10
6.1 General....................................................................................................................................... 13
6.2 Resistance values under 1 Ω—Kelvin double-bridge method................................................... 13
6.3 Resistance values from 1 Ω to many kilohms ........................................................................... 14
6.4 Digital ohmmeter—Resistance values from under 1 Ω to many kilohms ................................. 17
8.1 General....................................................................................................................................... 26
8.2 Measurement methods ............................................................................................................... 28
8.3 Impedance unbalance................................................................................................................. 29
8.4 Balance tests............................................................................................................................... 31
8.5 Polarity tests............................................................................................................................... 31
9. Transformer capacitance.................................................................................................................... 33
9.1 General....................................................................................................................................... 33
9.2 Interwinding capacitance ........................................................................................................... 34
9.3 Distributed capacitance.............................................................................................................. 35
9.4 Bridge methods .......................................................................................................................... 36
v
CLAUSE PAGE
10.1 General....................................................................................................................................... 36
10.2 Method of measurement ............................................................................................................ 37
13.1 General....................................................................................................................................... 46
13.2 Return-loss method .................................................................................................................... 46
15. Self-resonance.................................................................................................................................... 50
15.1 General....................................................................................................................................... 50
15.2 Measurement.............................................................................................................................. 50
16.1 General....................................................................................................................................... 51
16.2 Recommended voltage-time product test methods .................................................................... 52
vi
CLAUSE PAGE
20.1 Measurement.............................................................................................................................. 64
20.2 Calculation ................................................................................................................................. 64
20.3 Other considerations .................................................................................................................. 65
21.1 General....................................................................................................................................... 66
21.2 Recommended test procedure for current-transformation ratio and phase angle ...................... 66
ANNEX
Annex A (informative) Instrumentation for voltage and current measurements on inductors and
transformers ................................................................................................................................. 69
vii
IEEE Recommended Practice for
Testing Electronics Transformers and
Inductors
1. Overview
1.1 Scope
This recommended practice presents a number of tests for use in determining the significant parameters and
performance characteristics of electronics transformers and inductors. These tests are designed primarily for
transformers and inductors used in all types of electronics applications, but they may apply to the other types
of transformers of large apparent-power rating used in the electric power utility industry. Some of the tests
described are intended for qualifying a product for a specific application, while others are test practices used
widely for manufacturing and customer acceptance testing. Clause 4 is intended to serve as a guide for
particular application categories.
The tests described in this recommended practice include those most commonly used in the electronics
transformer industry: electric strength, resistance, power loss, inductance, impedance, balance, ratio of
transformation, and many others used less frequently.
The following are the specific types of transformers and inductors to which this recommended practice is
applicable:
a) Electronic power
1) Power
2) Isolating
3) Current limiting
4) Rectifier
5) Combination (rectifier and filament)
6) Ferroresonant
7) Converter
8) Polyphase
9) Switch mode
10) Magnetic amplifiers
b) Large rectifiers
c) Pulse
1
IEEE
Std 389-1996 IEEE RECOMMENDED PRACTICE FOR TESTING
1) Voltage stepdown
2) Voltage stepup
3) Low ratio inverting
4) Low power pulse
5) Square-loop
d) Broadband
1) Impedance matching
2) DC insulating
3) Common-mode rejection
4) Potential transformers
5) Current transformers
6) Filter inductors
7) Charging inductors
8) Hybrid transformers
2. References
This recommended practice shall be used in conjunction with the following publications. When the follow-
ing standards are superseded by an approved revision, the revision shall apply.
IEEE Std 4-1995, IEEE Standard Techniques for High-Voltage Testing (ANSI).2
IEEE Std 100-1996, IEEE Standard Dictionary of Electrical and Electronics Terms.
IEEE Std 119-1974, IEEE Recommended Practice for General Principles of Temperature Measurement as
Applied to Electrical Apparatus.4
IEEE Std 260.1-1993, IEEE Standard Letter Symbols for Units of Measurement (SI Units, Customary Inch-
Pound Units, and Certain Other Units) (ANSI).
IEEE Std 272-1970 (Reaff 1976), IEEE Standard for Computer-Type (Square-Loop) Pulse Transformers.5
IEEE Std 280-1985, IEEE Standard Letter Symbols for Quantities Used in Electrical Science and Electrical
Engineering (ANSI).
IEEE Std 295-1969 (Reaff 1993), IEEE Standard for Electronics Power Transformers (ANSI).
IEEE Std 315-1975 (Reaff 1993), IEEE Standard Graphic Symbols for Electrical and Electronics Diagrams
(ANSI/DoD).
1ANSI publications are available from the Sales Department, American National Standards Institute, 11 West 42nd Street, 13th Floor,
New York, NY 10036, USA.
2IEEE publications are available from the Institute of Electrical and Electronics Engineers, 445 Hoes Lane, P.O. Box 1331, Piscataway,
NJ 08855-1331, USA.
3IEEE Std 111-1984 has been withdrawn; however, copies can be obtained from Global Engineering, 15 Inverness Way East, Engle-
wood, CO 80112-5704, USA, tel. (303) 792-2181.
4IEEE Std 119-1974 has been withdrawn; however, copies can be obtained from Global Engineering, 15 Inverness Way East, Engle-
wood, CO 80112-5704, USA, tel. (303) 792-2181.
5IEEE Std 272-1970 has been withdrawn; however, copies can be obtained from Global Engineering, 15 Inverness Way East, Engle-
wood, CO 80112-5704, USA, tel. (303) 792-2181.
2
IEEE
ELECTRONICS TRANSFORMERS AND INDUCTORS Std 389-1996
IEEE Std 390-1987 (Reaff 1993), IEEE Standard for Pulse Transformers (ANSI).
IEEE Std 393-1991, IEEE Standard Test Procedures for Magnetic Cores (ANSI).
IEEE Std 436-1991, IEEE Guide for Making Corona (Partial Discharge) Measurements of Electronics
Transformers (ANSI).
IEEE Std C57.12.91-1995, IEEE Standard Test Code for Dry-Type Distribution and Power Transformers
(ANSI).
3. Definitions
Electrical and magnetics terms used in this recommended practice are in accordance with those given in
IEEE Std 100-19966. Certain parameters and symbols of particular significance in the evaluation of
electronics transformers are given where required in the text.
3.1 burden: That property of the circuit connected to the secondary winding that determines the real and
reactive power at the secondary terminals. It is expressed either as total impedance with effective resistance
and reactance components or as the total voltamperes and power factor at the specified value of current and
frequency.
3.2 current-transformation ratio (as opposed to turn ratio): The ratio of the root mean square (rms) value
of the primary current to the rms value of the secondary current under specified conditions.
3.3 phase angle (of a current transformer): The phase displacement between the primary and secondary
currents. The phase angle is positive when the secondary current leads the primary current.
Recommended tests and specifications for specific transformer groups are listed in table 1.
5.1 General
An abnormally high alternating voltage is applied between two (or more) isolated elements of the
transformer (windings, shields, core, frame, etc.) to test the integrity of major insulation systems in order to
demonstrate that the design, materials, and workmanship are adequate.
Unless otherwise specified, the tests should be made in accordance with IEEE Std 4-1995.
3
IEEE
Std 389-1996 IEEE RECOMMENDED PRACTICE FOR TESTING
Common-mode rejection
Potential transformers
Impedance matching
Current transformers
Hybrid transformers
Low ratio inverting
Charging inductors
Applicable ratings and
Voltage stepdown
Current limiting
performance
Filter inductors
Converter (HF)
Voltage stepup
Ferrorresonant
Large rectifier
specifications
Switch mode
Combination
DC isolating
Polyphase
Filament
Isolating
Rectifier
Power source
Voltage and range; ac x x x x x x x x x x x x x x x x x x x x
or dc; polyphase
Frequency and range x x x x x x x x x x x x x x x x x x
Pulse width(s) and x x x x
shape
Repetition rate and x x x x
max duty cycle
Effective impedance x x x x x x x x x
Primary ratings
Voltages and taps x x x x x x x x x x x x x x x x x x
Currents and taps x x x x x x x x x x x x x x x x x x x x x
Polarity x x x x x x x x x x x x x x x
DC resistance x x x x x x x x x x x x x x x x x x x x x
Inductance at rated dc x x x x x x
Exciting current x x x x x x x x x x x x
Effective impedance x x x x x x x
under load
Distributed x x x x x x
capacitance
Insulation voltages x x x x x x x x x x x x x x x x x x
Secondary ratings
Voltage (open circuit x x x x x x x x x x x x x x x x x x
or loaded, or both)
Currents x x x x x x x x x x x x x x x x x x x
Voltage waveshape x x x x x
under load
Frequency response x x x x
under load
Distortion x x x x
Voltage ratio and x
errors
Current ratio and x
errors
Leakage impedances x x x x x x x x x x x
and reactances
4
IEEE
ELECTRONICS TRANSFORMERS AND INDUCTORS Std 389-1996
Common-mode rejection
Potential transformers
Impedance matching
Current transformers
Hybrid transformers
Applicable ratings and
Charging inductors
Voltage stepdown
performance
Current limiting
Filter inductors
Converter (HF)
Voltage stepup
Large rectifier
Ferroresonant
specifications
Switch mode
Combination
DC isolating
Polyphase
Filament
Isolating
Rectifier
Secondary ratings
(Continued)
Regulation for input x
voltage range
Insulation voltages x x x x x x x x x x x x x x x x x x x
Polarities x x x x x x x x x x x x x x x
DC resistances x x x x x x x x x x x x x x x x x x x
Losses
Core x x x x x x x x x x x x x x x
Conductor x x x x x x x x x x x x x x x
Efficiency x x x x x x x x x x x x x
Load x
Capacitance x x x x x
Commutation x
Insertion x x x x
Trans-hybrid x x
Temperature rise
Case x x x x x x x x x x x x x x x
Conductor x x x x x x x x x x x x x x x
Hot spot x x x x x x x x x x x x
Shielding
Electrostatic x x x x x x x x x x x x
Electromagnetic x x
Load
Resistance x x x x x x x x x x x x x x x x x x x x
Inductance x x x x x x x x x x
Capacitance x x x x x x x x x x x x x x x x x
Range x x x x x x x x x x x x x x
Nonlinear x
(transmitter tube)
Rectifier x x x x x x x
Recommended
acceptance tests
Conductor resistances x x x x x x x x x x x x x x x x x x x x x
Winding terminal x x x x x x x x x x x x x x x x x x x x x
polarities
5
IEEE
Std 389-1996 IEEE RECOMMENDED PRACTICE FOR TESTING
Common-mode rejection
Potential transformers
Impedance matching
Current transformers
Hybrid transformers
Applicable ratings and
Charging inductors
Voltage stepdown
performance
Current limiting
Converter (HF)
Filter inductors
Voltage stepup
Large rectifier
Ferroresonant
specifications
Switch mode
Combination
DC isolating
Polyphase
Filament
Isolating
Rectifier
Insulation tests
Resistance x x x x x x x x x x x x x x x x x x x x x
Applied potential x x x x x x x x x x x x x x x x x x x x x
(hipot)
Induced potential x x x x x x x x x x x x x x x x x x
Impulse voltage x
Corona extinction x x x x x x x x x x x x x x
voltage above 500 V
Electrical
characteristics
Open-circuit secondary
(secondaries)
Primary inductance at x x x x x x
rated dc
Primary exciting x x x x x x x x x x x x
current
Primary exciting x x x
impedance
Primary excit. power x x x x x x x x x x
Primary-to-secondary x x x x x x x x x x x x x x x x x x
voltage ratios
Short-circuit secondary
(secondaries)
Primary voltage for x x x x x
rated primary current
Primary voltage for x x x x
rated second. current
Primary power for x x x x x x
rated primary current
Primary inductance x x x x x x x x x x x x
(leakage inductance)
Current ratios x
Commutating x
inductance
Primary distributed x x x x x x
capacitance
Short-circuit primary
Secondary distributed x x x x x x
capacitance
6
IEEE
ELECTRONICS TRANSFORMERS AND INDUCTORS Std 389-1996
Electric strength testing shall always be done with all the windings short-circuited. Windings and shields
on one side of the insulation system should be connected to frame and ground, while windings and shields
on the other side should be connected together (see figures 1 and 2). An essentially sine-wave voltage with
a frequency in the range of 45–65 Hz, having adequate current capacity for the application, is applied to
the two sets of terminals. The criterion for passing this test is that no electrical breakdown occurs (refer to
annex B). All voltages should be defined in the same terms [e.g., root mean square (rms)], peak, or
average.
The voltage should be increased at a convenient rate of not greater than 2000 V/s from zero to the specified
value, maintained for 1 min (unless breakdown occurs), and then decreased to zero at the same rate. For
production purposes, a voltage 20% higher may be specified for 2 s.
a) Primary windings with rated voltages 600 V or less line-to-line should be tested at an alternating
voltage equal to twice the rated voltage of the highest tap plus 1000 V rms, unless otherwise
specified.
b) Primary windings with rated voltages over 600 V line-to-line should be tested in accordance with
IEEE Std C57.12.91-1995, unless otherwise specified.
7
IEEE
Std 389-1996 IEEE RECOMMENDED PRACTICE FOR TESTING
c) Secondary windings that have no special test voltage specified should be tested with applied
alternating voltage equal to twice the rated voltage of the highest voltage tap plus 1000 V rms, unless
otherwise specified.
d) Secondary windings that may have a specific operating direct or alternating voltage derived else-
where, unless otherwise specified, should be tested at twice the working voltage plus 1000 V rms.
High alternating voltage should not be substituted for a direct voltage unless agreed upon between
user and manufacturer.
e) Inductors used in line-voltage circuits should be tested in accordance with item a) or b), as applica-
ble. Inductors used in transformer secondary winding circuits should be tested in accordance with
item c) or d), as applicable.
f) In case of repeated electric strength testing, since the application of test potentials may impair the
strength of the transformer or inductor insulation, any test carried out in accordance with items a)
through e) should, if repeated, be made at not more than 80% of the specified test potential for the
same time interval.
This test applies primarily to insulation systems between layers of windings and between adjacent turns of
windings under simulated abnormal functional conditions.
Each secondary winding shall be terminated in an open circuit or into a load resistance that is not less than
2.5 times its normal operating load resistance. All terminals normally grounded shall be grounded during
this test and any windings normally biased shall be biased for this test.
Transformers normally driven by a voltage pulse train with pulse duration modulation (or pulse time modu-
lation) should withstand across the primary an induced voltage pulse train for 1 min or 7200 cycles, which-
ever is less, with each pulse having an amplitude equal to twice the highest normal operating voltage. The
pulse should have a duration equal to half the longest normal pulse duration such that the test voltage-time
product does not exceed the normal maximum operating voltage-time product.
di
An alternative test is based on current interruption in an inductance producing a voltage pulse E = L ----- .
dt
By means of the induced potential surge test, electrical coils may be conveniently tested for the integrity of
turn-to-turn and layer-to-layer insulation by means of high-voltage pulses generated within the coil
(figure 3).
8
IEEE
ELECTRONICS TRANSFORMERS AND INDUCTORS Std 389-1996
This type of testing is especially applicable to coils wound without interlayer insulation, in a random,
controlled random, universal, or layer-wound manner, since the method may cause failure of the coil when
one or more of the following faults exist:
It should be kept in mind that the test itself is destructive in nature and cannot be applied to a sound coil for
an extended period. Therefore, the test duration should be carefully controlled to limit it to the minimum
time required to obtain a meaningful indication.
The test consists of applying a controlled train of current pulses to the coil. The leading edge of the pulses
may have a moderate slope to allow the current in the coil to rise to a predetermined level. Once this level is
reached, the current is disconnected from the coil, and the resultant voltage rise, due to the fast collapse of
the current through the inductance of the coil, is observed on an oscilloscope or by means of a comparator to
establish the peak value reached E = L ----
di
- .
dt
The coil should be unloaded during this observation so that the voltage is not limited by some unspecified
loading. A high-impedance input oscilloscope coupled to the circuit with a frequency-compensated high-
impedance voltage divider may be used. Loading should be of the order of 1–10 MΩ.
It is not necessary to have a horizontal sweep operating on the oscilloscope. Prior to the application of the
test, the spot on the oscilloscope can be conveniently centered horizontally and can rest on some base level
near the bottom of the screen. During the test the excursion of the spot is observed against the calibration of
the screen, which acts as a peak reading voltmeter. A 0.5–1.0 s time interval at a 120 Hz rate is sufficient to
allow an operator to visually detect any drop or instability in the image caused by internal short circuits that
load the coil.
A more sophisticated method uses a comparator consisting of a dc-biased diode bucked against the rising
waveform as a detecting device. With the dc bias set to the desired test voltage level, the peak current
through the coil is adjusted until the peak exceeds the dc bias by some predetermined amount (10–20 V).
The top of the pulse train is clipped and fed to a counter. Pass or fail can be determined by comparing the
count with the total number of pulses. If the clipped pulse count is less than the total number of pulses
applied by more than, for example, two or three counts, a failure indication is obtained.
In order to ensure the successful generation of high-voltage pulses without the use of excessive current, the
test coil should be placed over an iron core during the test. Best results are obtained from cores made up of
thin nickel-iron laminations. The core should be grounded for operator protection.
As a precaution against unwarranted damage to the coil, the test current should always be increased from
zero until the observation yields the desired voltage level. A test coil may be used for calibration and saved if
production of an item is apt to be repeated. The proper current level set on this coil can then be used on the
production coils without further adjustment.
Some suggestions as to the determination of the desired voltage level to be used in a specific coil follow.
Assume a coil consisting of 10 000 turns of 36 AWG magnet wire with an insulation rated at 400 V/mil,
wound on a form with 250 turns per layer, and therefore having 40 layers. The insulation thickness of the
wire is 0.0005 in; therefore two wires laid tightly side by side, having 2 × 0.0005 in separation (0.001 in)
should withstand 400 V for an extended time.
9
IEEE
Std 389-1996 IEEE RECOMMENDED PRACTICE FOR TESTING
The voltage across each layer is obviously 1/40 of the total voltage across the coil. Therefore, the maximum
voltage between two wires touching one another, if there is no dropoff at the ends of the coil, occurs between
the end turns on adjacent layers and amounts to 1/20 of the voltage across the entire coil.
Suppose our test criterion is that a coil where the end turn drops two layers should be acceptable. The volt-
age between these turns then can be 1/10 of the total across the coil. If 400 V is a passing level, then 400
times 10, or 4000 V, should be the peak voltage generated in the coil.
It can be seen from the preceding text that long coils with fewer layers are more apt to fail a surge test than
short coils of many layers.
In the preceding example, it now becomes obvious that the crossover lead insulation should withstand at
least 4000 V peak.
Transformers normally driven by a sine-wave or square-wave source should withstand, across the primary,
an induced voltage of twice the highest normal operating voltage at a frequency of twice the normal operat-
ing frequency.
In case of repeated induced voltage testing, since the application of test potentials may impair the strength of
the transformer insulation, any test carried out in accordance with 5.3.1 or 5.3.2 should, if repeated, be made
at not more than 90% of the specified test potential for the same time interval.
The input currents should be monitored during the test to check for erratic variations in value. A subsequent
normal excitation test should not show a significant change in value from that of a previous test.
5.4.1 General
Corona is a partial discharge of electrical charges distributed in an insulation system due to the transient
ionization of a gas that is part of the insulation system. The gas may be surrounding the conductor as in the
case of a terminal, or it may be trapped in a solid or liquid dielectric in the form of a void or bubble in a loca-
tion where the electric field strength exceeds that necessary to ionize the gas. For detailed treatment of the
subject, see [B3]7 and [B7].
Many insulating materials will rapidly fail when in contact with ionized gasses, making the detection and
measurement of corona in insulation systems important.
The unit of test sensitivity of measuring or detecting corona discharges is the picocoulomb, representing the
charge transferred due to partial ionization. The quantity affecting the life of the insulation system is the
energy that can be transferred by the discharges and is normally expressed in nanojoules. The two units are
related:
10
IEEE
ELECTRONICS TRANSFORMERS AND INDUCTORS Std 389-1996
1
W = --- Q a V 1 (1)
2
where
W is energy, in nanojoules
Qa is discharge magnitude, in picocoulombs
V1 is applied peak voltage, in kilovolts
The detection of corona at the levels normally encountered in electronics transformers is done by sensing the
sudden change of potential distribution in the circuit made up of the insulation system under stress, the cou-
pling impedances, and the test voltage source, caused by the discharge current pulses.
Typical test circuits are shown in figures 4 and 5. For details see IEEE Std 436-1991.
Corona discharges of higher levels may be detected by acoustical means (hissing, cracking sounds, ultra-
sonic) or by visual means (blue haze).
LEGEND
Ccc is coupling capacitor
Cc is calibration coupling capacitor
Zc is coupling impedance
E is high-impedance test voltage supply
For reliable operation, an insulation system should be free of corona discharges. The insulation system may
be characterized by the corona inception voltage, i.e., the voltage where corona discharges of a specified
magnitude first appeared; or by the corona extinction voltage, i.e., the lowest voltage where corona
discharges were detected as the applied voltage was reduced from a level above the corona inception voltage.
The corona extinction voltage is equal to or less than the corona inception voltage.
11
IEEE
Std 389-1996 IEEE RECOMMENDED PRACTICE FOR TESTING
LEGEND
Ccc is coupling capacitor
Cc is calibration coupling capacitor
Zc is coupling impedance
E is high-impedance test voltage supply
Where the maximum voltage that can stress the insulation is well defined (including the transients), the insu-
lation quality may be assured by determining that the corona inception voltage is above that level by a spec-
ified amount.
Where this is not possible, the insulation system should have a corona extinction voltage that is above the
maximum continuous voltage that can stress the insulation.
The normal requirement is no detectable corona at the specified test voltage and pulse or energy level.
The pulse energy levels recommended by IEEE Std 436-1991 are as follows:
— Class I. 70 nJ maximum for insulation systems with a history of satisfactory life at the voltage stress
used
— Class II. 700 nJ maximum for insulation with considerable tolerance for corona such as inorganic
insulation
— Class III. Pulse energy level to be specified
12
IEEE
ELECTRONICS TRANSFORMERS AND INDUCTORS Std 389-1996
6. DC resistance tests
6.1 General
A number of tests for measuring dc resistance of transformer and inductor coils are presented in this clause.
The range of resistance values that can be measured using these tests varies from a few microhms to many
thousands of ohms. The recommended methods of testing dc resistance are the kelvin double bridge for
resistance values less than 1 Ω and the Wheatstone bridge for resistance values greater than 1 Ω. The digital
ohmmeter is recommended for both of these resistance ranges. The ammeter-voltmeter and substitution
methods are presented for possible use when the previously mentioned equipment is not available.
Methods of measurement that are suitable for measurements above 1 Ω may be unsuitable for low-resistance
measurements chiefly because contact resistance causes serious errors.
It is usually essential with low resistance that the two points between which the resistance shall be measured
be very precisely defined. The methods that are specially adapted to low-resistance measurement employ
potential connections, i.e., connecting leads that form no part of the circuit whose resistance is to be mea-
sured but that connect two points, in this circuit, to the measuring circuit. These two points are referred to as
the potential terminals and serve to fix, definitely, the length of the circuit under test. In the methods used for
the precise measurement of low resistance, the “unknown” resistance is compared with a low-resistance
standard of the same order as the unknown, and with which it is connected in series. Both resistances are fit-
ted with four terminals, two current terminals to be connected to the supply circuit and two potential termi-
nals to be connected to the measuring circuit. This arrangement is shown in figure 6.
This method is a development of the Wheatstone bridge by which the errors due to contact and load resis-
tances are eliminated. The connections of the bridge are shown in figure 7.
X is the low resistance to be measured and S is the standard resistance of the same order of magnitude. These
are connected in series with a low-resistance link r, connecting their adjacent current terminals. A current is
passed through them from a battery supply. A regulating resistance and an ammeter are connected in the cir-
cuit for convenience. Q, M, q, and m are four known noninductive resistances, one pair of which (M and m or
Q and q) are variable. These are connected to form two sets of ratios as shown, a sensitive galvanometer G
connecting the dividing points of QM and qm. The ratio Q/M is kept the same as q/m, these ratios being var-
ied until zero deflection of the galvanometer is obtained. Then X/S = Q/M = q/m, from which X is obtained in
terms of S, Q, and M:
Q
X = ----- ⋅ S (2)
M
13
IEEE
Std 389-1996 IEEE RECOMMENDED PRACTICE FOR TESTING
In order to take into account thermoelectric electromotive forces (EMF), a measurement should be made
with the direction of the current reversed, and the mean of the two readings should be taken as the correct
value of X.
This method, which is the simplest of all, is in common use for the measurement of low resistances when an
accuracy of 1% is sufficient. However, this is a relatively rough method, the accuracy being limited by that of
the ammeter and voltmeter used, even if corrections are made for the “shunting” effect of the voltmeter. In
figure 8, R is the resistance to be measured and V is a high-resistance voltmeter of resistance Rv. A current
from a steady dc supply is passed through R in series with a suitable ammeter.
14
IEEE
ELECTRONICS TRANSFORMERS AND INDUCTORS Std 389-1996
Assuming the current through the unknown resistance to be the same as that measured by ammeter A, the
former is given by
voltmeter reading
R = ------------------------------------------
ammeter reading
If the voltmeter resistance is not very large compared with the resistance to be measured, the voltmeter
current will be an appreciable fraction of current I, measured by the ammeter, and a serious error may result.
To correct for the shunting effect of the voltmeter, if the actual value of the unknown resistance is R, its
measured value Rm, the voltmeter and R in parallel is
R⋅R
---------------v
R + Rv
R ⋅ Rv
I --------------- = voltmeter reading (3)
R + Rv
I R⋅R R⋅R
- ---------------v = ---------------v (4)
I R + Rv R + Rv
and
Rm ⋅ Rv
R = ------------------ (5)
Rv – Rm
NOTE—The current I required to give an acceptable reading for the voltmeter should not cause a heating of the resistor.
The diagram of connections for this method is given in figure 9. X is the resistance to be measured while R is
a variable known resistance. A battery of adequate capacity is used for the supply, since it is important in this
method that the supply voltage be a constant. A is an ammeter of suitable range or a galvanometer with a
shunt that can be varied as required.
With switch S2 closed and switch S1 on stud a, the deflection of the ammeter or galvanometer is observed.
S1 is then closed onto stud b, and the variable resistance is adjusted until the same deflection is obtained on
the indicator. The value of R that produces the same deflection gives the resistance of the unknown directly.
The resistances R and X should be large compared with the resistance of the rest of the circuit.
The accuracy of the measurement depends upon the consistency of the supply voltage of the resistance of the
circuit excluding X and R and upon the sensitivity of the indicating instrument as well as the accuracy with
which the resistance R is known.
15
IEEE
Std 389-1996 IEEE RECOMMENDED PRACTICE FOR TESTING
The general arrangement is shown in figure 10. P and Q are known fixed resistors, S being a known variable
resistance, and R the unknown resistance. G is a sensitive galvanometer shunted by a variable resistance N to
avoid excessive deflection of the galvanometer when the bridge is out of balance. This shunt is increased as
the bridge approaches balance so that the shunting is zero, giving full sensitivity of the galvanometer when
balance is almost obtained. B is a battery and M is a reversing switch, so that the battery connections to the
bridge may be reversed and two separate measurements of the unknown resistance may be made in order to
eliminate thermoelectric errors. KB and KG are keys fitted with insulating press buttons, so that the hand
does not come into contact with metal parts of the circuit, thus introducing thermoelectric EMFs. The battery
key KB should be closed first, followed by the closing of KG after a short interval. This avoids a sudden (pos-
sibly excessive) galvanometer deflection due to self-induced EMFs when the unknown resistance R has
appreciable self-inductance.
At balance (obtained by adjustment of S) the same current i1 flows in both arms P and Q since the galvanom-
eter takes no current, and the same current i2 flows in arms R and S.
The voltage drop across arm P equals the voltage drop across arm R, and the voltage drop across arm Q
equals the voltage drop across arm S. Then
16
IEEE
ELECTRONICS TRANSFORMERS AND INDUCTORS Std 389-1996
i1 P = i2 R
i1 Q = i2 S
(6)
PS
R = -------
Q
Arms P and Q are the “ratio arms” of the bridge, and the ratio P/Q may be varied as required to increase the
range of the bridge.
Wheatstone bridges are normally constructed with either four or six pairs of ratio coils (tens, hundreds, thou-
sands, and ten thousands in the bridge containing four pairs) and either four or five decades of resistance
coils that constitute the variable arm S.
6.3.4 Ohmmeter
The ohmmeter has a moving coil meter, a dry cell, a fixed resistor R1 and a variable resistance R2, all
mounted within the instrument (figure 11). The unknown resistance R to be measured is connected across the
two terminals A and B when the battery circuit is completed. The current flowing through the meter depends
on the total resistance of this circuit of which R forms a part, and if R is large the current is small, while if R
is small the current is large. The dial of the meter is marked to read directly in ohms. The meter reading
would depend to some degree on the state of the battery, but this difficulty is avoided by adjusting the instru-
ment just before each measurement as follows.
Terminals A and B are first short-circuited by a thick piece of copper wire of negligible resistance, and R2 is
adjusted until the meter shows its maximum deflection, indicating zero resistance. The copper wire is then
removed and the resistance to be measured is connected across AB when the deflection of the pointer indi-
cates the value of R. The instrument scale is very cramped at the higher resistance end, for the deflections
correspond more to values of I/R than of R, and it is most sensitive for low resistances. Usually several
ranges of resistance are marked on the dial (e.g., 0–1000 Ω, 0–10 000 Ω, 1–100 000 Ω).
This method is a development of the ammeter and voltmeter method. The general arrangement of this test
method is shown in figure 12. Digital ohmmeters utilize constant current sources, digital electronics, and
four terminal connections to provide an accurate indication of resistance values.
Digital ohmmeters provided as dedicated stand-alone instruments incorporating the previously mentioned
technologies can provide accurate measurements of resistance from a few microhms to many kilohms. Digi-
tal ohmmeters provided as one of the functions of a digital multimeter generally do not incorporate all the
previously indicated technologies.
17
IEEE
Std 389-1996 IEEE RECOMMENDED PRACTICE FOR TESTING
NOTE—Digital ohmmeters that utilize pulsed dc current sources, as opposed to constant dc sources, may introduce
errors due to the inductance associated with the coil’s winding.
The accuracy of this type of digital ohmmeter is limited at lower values of resistance. Vendor specifications for the accu-
racy of these devices should be checked against the measurement requirements.
7. Loss measurements
Transformer no-load loss is defined as the power measured in one transformer winding under specified con-
ditions of excitation and with the voltage-current product equal to zero in all other windings of the trans-
former. For voltage transformers, the voltage current product is zero when the winding is open-circuited; for
current transformers, when the winding is short-circuited. The following discussions refer only to voltage
transformers; tests associated with current transformers are presented in clause 21. The term no-load loss is
often interchanged with the terms core loss, magnetic loss, or excitation loss, and, under many conditions of
operation, there is little difference between the no-load loss and the loss components described by the other
three terms. In general there are three components of transformer no-load loss: core loss, ohmic loss in the
winding being excited, and (in high-voltage transformers) dielectric loss. In transformers with a magnetic
core, the core-loss component is usually much larger in magnitude than the other two components. However,
in air-core transformers this component is zero.
The core-loss component of no-load loss is a function of several parameters determined by the source used
to excite the transformer. This is a nonlinear functional dependence, which also varies greatly with the type
and construction of core material. The principal characteristics of the excitation source affecting transformer
core loss are its frequency, waveshape, and voltage (as it affects the magnetic flux density in the core). These
parameters, along with the ambient or core temperature, should be specified for all no-load tests.
Until recently, most transformer and core testing was specified in terms of the parameters associated with
sinusoidal excitation; most core-loss data supplied by the manufacturers of core material are still given only
for sinusoidal excitation. Tests using only sinusoidal excitation may not give an adequate measure of the
transformer core loss for many applications in which electronics transformers are used, such as in inverter
circuits, choppers, switching circuits, and various pulse applications. Therefore the no-load test excitation
source should be specified to be as close as possible to that which will excite the transformer in actual oper-
ation. Guides for specifying source waveforms are discussed below.
18
IEEE
ELECTRONICS TRANSFORMERS AND INDUCTORS Std 389-1996
The core is excited with a sinusoidal alternating voltage source of very low internal impedance to minimize
distortion caused by the nonlinear exciting current. The total harmonic distortion of the induced voltage
should be less than 5% in order for this distortion not to affect core loss. This is a very common mode of
excitation for core-loss testing and the one by which most manufacturers’ loss data are obtained. Magnetic
flux density and induced voltage are related by the following well-known relationship:
where
Note that the constant in equation (7) results from the values relating average and rms values to maximum
values that are peculiar to a sine wave:
2 1
M av = --- M m ; M rms = ------- M m
π 2
Suggested values for specifying no-load tests for various core materials are given in table 2.
Operating flux
density Operating
Material thickness
Material frequency
(in)
(Hz)
(G) (T)
19
IEEE
Std 389-1996 IEEE RECOMMENDED PRACTICE FOR TESTING
The core is excited with a sinusoidal current provided by a high-impedance source to minimize the distortion
of the current wave by the voltage induced across the core winding. This induced voltage and the associated
flux density in the core will generally be nonsinusoidal due to the nonlinear B-H characteristic of the core
material. There is no simple relationship between flux density and voltage as in equation (7) or in 7.1.1.1.
Peak flux density can be determined graphically from the core material B-H characteristic and the specified
input current, if desired. One method for specifying the current source for this type of excitation is given in
6.4.1 of IEEE Std 393-1991.
The core is excited with an alternating square-wave voltage source of very low output impedance to
minimize distortion caused by the nonlinear exciting current. The auxiliary-commutated silicon controlled
rectifier (SCR) bridge inverter, or McMurray-Bedford inverter [B5], with lead-acid battery energy source, is
a simple circuit for achieving such a square-wave excitation source, although many commercial inverters are
readily available. With ideal square-wave excitation from a low-impedance source, the flux-density variation
in the transformer core is triangular in shape as shown in figure 13, and the maximum flux density in the core
is related to the induced voltage by the relationship
where E represents the maximum, rms, and half-wave average of the square-wave-induced voltage, and the
other symbols have the same meaning as in equation (7).
In practical circuits the ideal square-wave voltage source can seldom be realized. Therefore, for the purposes
of no-load transformer loss testing, a source may be considered a square-wave source if it contains the fun-
damental frequency component and measurable values of all odd harmonics of the fundamental through the
15th harmonic. Suggested values for specifying flux densities and frequencies may be taken from table 2.
Transformer no-load losses can be measured easily by means of instrumentation available in the average lab-
oratory. The accuracy of the measurement is a function of the accuracy of the instruments used, and instru-
ments with rated accuracy of 1% of full-scale deflection or less are recommended. For measurements in
systems with irregular or very nonsinusoidal waveshapes, wattmeters with accuracies of even 1% will be dif-
ficult to find. The simplest test circuit is shown in figure 14. The measurement may be performed on any of
the transformer windings. Care should be taken to isolate the other windings, which shall be left open-cir-
cuited, from test personnel and other equipment. In this circuit an electrodynamometer type wattmeter is
illustrated. This the most common type of wattmeter, available in most laboratories. The requirements of the
wattmeter and other instruments will now be discussed.
20
IEEE
ELECTRONICS TRANSFORMERS AND INDUCTORS Std 389-1996
7.1.2.1 Wattmeter
The wattmeter used to measure no-load transformer losses should be of the low-power-factor type, should
have a frequency response equal to the highest frequency components in the voltage and current signals
being measured, and should have a certified accuracy. The power factors in transformer no-load tests may
easily be 0.1 or less, and the wattmeter should be designed and calibrated for power measurements in this
power-factor range.
The most common type of wattmeter is the electrodynamometer (dynamometer) type, which indicates aver-
age power. Low-power-factor dynamometer wattmeters are generally calibrated for power factors up to 0.2,
which means that the full-scale value on the wattage scale is 0.2 times the product of current-coil rating and
voltage-coil rating. The calibrated accuracy of this type of wattmeter is achievable, and an upscale reading is
obtained only when current and voltage coils are connected to the proper voltage points in the circuit. Each
coil has one terminal designated by a polarity mark (±), and these terminals should be connected as shown in
figure 14. With connections as shown, the power loss in the voltage coil is not included in the wattmeter
reading. Standard dynamometer wattmeters have a frequency range up to 800 Hz and accuracies of 0.25% to
1% of full scale, and can be used on all sine-voltage or sine-current excitation tests in this frequency range.
Specially calibrated low-power-factor instruments for use at excitation frequencies up to 3200 Hz are also
available. Dynamometer wattmeters may also be used with square-wave excitation if the inductive reactance
of the voltage-coil circuit is minimized (or compensated for) so as to be 1/1000 of the voltage-coil circuit
resistance at the fundamental frequency of the square wave. However, even with this precaution, the wattme-
ter reading will be less accurate with square-wave excitation than with sinusoidal excitation due to phase-
angle errors unless specifically recalibrated with square-wave excitation by means of a calorimeter. In using
the circuit of figure 14, the sum of the power losses in the voltmeter and ammeter should be less than the
wattmeter probable error times the wattmeter scale reading.
NOTE—The meter I should be shorted out and meter V should be opened to ensure that they do not affect the wattmeter
reading.
There are other types of wattmeters that can be used to measure no-load losses in transformers excited by
highly nonsinusoidal signals, such as those associated with inverters, SCR choppers, pulse generators, etc.
These include thermal, Hall-effect, and electronic-multiplier wattmeters. These devices generally have a
much higher frequency response than the dynamometer type; however, their accuracies seldom achieve 1%,
and most have not been calibrated for low-power-factor service and may have large phase-angle errors.
These wattmeters and their applications are discussed in more detail in 6.3.2 of IEEE Std 393-1991.
7.1.2.2 Ammeters
A thermocouple (or true rms responding) meter is suggested for all types of excitation since current during
the no-load test is nonsinusoidal except with sine-current excitation. Commercial thermocouple ammeters
have frequency response capabilities into the megahertz range and accuracies of 0.5–1% of full scale, which
are adequate for no-load tests. Thermocouple meters indicate true rms current or voltage regardless of wave-
shape.
21
IEEE
Std 389-1996 IEEE RECOMMENDED PRACTICE FOR TESTING
NOTE—Care must be exercised to avoid introducing errors due to the self heating effect.
7.1.2.3 Voltmeters
A thermocouple voltmeter (or true rms responding) meter is suggested for all the same reasons as discussed
in 7.1.2.2.
NOTE—Care must be exercised to avoid introducing errors due to the self heating effect.
The transformer no-load loss varies with voltage, frequency, and waveform. These parameters and ambient
temperature should be specified for each no-load loss measurement and should be stated when presenting or
listing the value of the loss. Specifications for various types of transformer excitation are discussed in 7.1.1.
The wattmeter reading represents the total no-load loss of the transformer; the core loss (or excitation loss) is
found by subtracting ohmic loss in the exciting winding from the no-load loss. The ohmic loss should be cal-
culated using the no-load current measured during the no-load test. In transformers with high-voltage wind-
ings, part of the no-load loss may also be composed of dielectric and corona losses. These may be separated
from the other no-load test. For more complete analysis of corona loss, see IEEE Std 436-1991.
The excitation apparent-power also is found from the no-load test as described in 7.1. The average excitation
voltamperes are
2
P ex = ( VI ) 2 – W [voltampere] (9)
where
The excitation apparent power is often termed voltamperes reactive and abbreviated as VAR.
Stray-load loss is a third component of transformer loss (in addition to the no-load and the ohmic or I2R loss)
and results from the flow of load current in the transformer windings. The two principal sources of the stray-
load loss are the increased ohmic loss in the transformer windings due to skin effect and eddy currents in the
windings, and the induced or eddy-current losses in the transformer case, mounting brackets, etc., due to
leakage fluxes. The stray-load loss is a component of the transformer load loss, so termed because it is a
function of the transformer load current. The other component of the load loss is the ohmic or I2R loss in the
windings, always much larger than the stray-load component. Both components are obtained from the short-
circuit power test of 7.4. The stray-load loss component may be separated out from the total load loss by the
method shown in 7.3.2.
The stray-load loss decreases with increasing temperature, in contrast to the ohmic component of the load
loss. This is due to the fact that the stray-load loss is an electromagnetically induced or eddy-current type
22
IEEE
ELECTRONICS TRANSFORMERS AND INDUCTORS Std 389-1996
loss that varies inversely with the magnitude of the resistance in the eddy paths. The stray-load loss may be
referred to another temperature by means of the relationship
( 234.5 + θ′ )
Copper conductors: P′ SL = P SL ----------------------------- [watt]
( 234.5 + θ )
( 226 + θ′ )
Aluminum conductors: P′ SL = P SL ------------------------- [watt] (10)
( 226 + θ )
where PSL and PSL are the stray-load losses at θ′ and θ, in °C, respectively.
The stray-load loss can be calculated from the results of the short-circuit power test (see 7.4) and the dc
resistance test (see clause 6) by means of the following steps:
a) Specify the winding temperature and load current at which the stray-load loss is desired.
b) Obtain voltage, current, power, and temperature measurements from the short-circuit power test at
the specified load current and temperature as outlined in 7.4.
c) Obtain the dc resistance of each transformer winding by means of the methods outlined in clause 6,
noting the winding temperature at the time of measurement.
d) Refer the dc resistances measured in step c) to the winding in which the short-circuit test measure-
ments were taken in step b) by means of the transformation ratios listed on the transformer name-
plate (or as measured by the technique outlined in clause 8). The sum of these referred resistances is
the transformer equivalent dc resistance RDCe.
e) Refer the equivalent dc resistance RDCe obtained in step d) to the specified temperature by the
relationship
( 234.5 + θ′ )
Copper conductors: R′ DCe = R DCe ----------------------------- [ohm]
( 234.5 + θ )
( 226 + θ′ )
Aluminum conductors: R′ DCe = R DCe ------------------------- [ohm] (11)
( 226 + θ )
where RDCe is the equivalent dc resistance at the temperature at which the resistance measurements were
performed, θ (°C), and R′DCe is the equivalent dc resistance at the temperature specified in step a), θ′ (°C).
P DC = ( I SC ) 2 ⋅ R′ DCe
(12)
h) If a negative number results from equation (13), assume that the stray-load loss PSL is zero.
23
IEEE
Std 389-1996 IEEE RECOMMENDED PRACTICE FOR TESTING
7.4.1 Purpose
The purpose of the short-circuit power test is to determine the losses due to the effective ac resistance of the
transformer, excluding the hysteresis losses of the core, at rated current.
The simplified diagram is shown in figure 15. The circuit consists of a power source of specified frequency,
an ammeter to monitor the primary current of the transformer, and a wattmeter to measure the losses in the
transformer’s primary circuit. The secondary winding is short-circuited with the least impedance practical.
a) The power source shall furnish the required voltage and current with a specified limit on harmonic
distortion.
b) The wattmeter shall indicate the real power lost in the transformer under test with the specified accu-
racy.
c) The ammeter shall indicate the rms current in the primary winding with a specified accuracy.
d) The short-circuiting conductor and its connections to the terminals of the secondary winding shall
have negligible impedances with respect to the secondary winding.
The transformer is connected in the test circuit. The input voltage should be raised from 0 V until the input
current, as read on the ammeter, shall equal the rated current. The power indicated by the wattmeter then is
where
NOTE—The measurement should be made as quickly as possible after excitation is applied to minimize the effects of
self heating.
24
IEEE
ELECTRONICS TRANSFORMERS AND INDUCTORS Std 389-1996
7.5.1 Efficiency
The efficiency of a device is the ratio of the power output from it to the total power input to the device,
expressed in percent:
power output
η = ------------------------------- ⋅ 100 (15)
power input
The efficiency of transformers can be more accurately calculated when the core and copper losses are known
from independent measurements or estimates:
input power–losses
η = ---------------------------------------------- ⋅ 100
input power
(16)
output power ⋅ 100
= ----------------------------------------------------
output power + losses
For a two-winding transformer supplying a load with a power factor (PF), the efficiency can be calculated as
V 2 I 2 ( PF )
η = ----------------------------------------------------------------------------------------- ⋅ 100 (17)
V 2 I 2 ( PF ) + core loss + copper losses
V 2 I 2 ( PF )
η = ------------------------------------------------------------------------------------------
- ⋅ 100 (18)
V 2 I 2 ( PF ) + core loss + I 12 R e 1 + I 22 R e 2
where
The core loss should be measured or estimated at the flux level required to induce V2 volt at the output under
operating conditions.
For multiple-winding transformers the power output to each load shall be added to get the total, and the
losses in all the windings shall be summed to obtain the total copper loss.
The power factor (PF) of a reactive circuit component is the ratio of the power input to the device to the total
voltampere product flowing into it:
P
PF = ---------- (19)
V⋅I
25
IEEE
Std 389-1996 IEEE RECOMMENDED PRACTICE FOR TESTING
where
Alternately,
P = V ⋅ I ( PF ) [watt] (20)
Since the power factor is also the cosine of the phase angle θ between V and I
If the device can be described by its component parameters, the resistive component R, the reactive compo-
nent X, and the total impedance Z, its power factor is
R R
PF = cos θ = ----------------------- = --- (22)
R +X2 2 Z
In an inductive device the current will lag in phase behind the applied voltage, thus the inductor is said to
have a lagging power factor. Accordingly, a capacitor has a leading power factor. In transformers the power
factor is determined by the reflected load impedances unless the magnetizing inductance is very low, or the
leakage inductances are very high with respect to the load (e.g., ferroresonant transformers).
8. Ratio of transformation
8.1 General
The ratio of transformation of two magnetically coupled windings is the transformer parameter determined
primarily by the ratio of the number of turns in each winding. By convention it is measured as the ratio of
voltages induced across each winding by a common exciting current, with the windings connected series
aiding (see 7.2). Thus it can be described as the forward voltage transfer ratio of the transformer with the
currents in the two windings being identical.
For an ideal transformer with windings of N1 and N2 turns, the ratio of transformation equals the turns ratio:
N
a 12 = ------1 (23)
N2
Due to the relationship between the number of turns and the inductance of the windings in an ideal trans-
former, the ratio of transformation is also equal to the square root of the ratio of the winding self-induc-
tances:
L
a 12 = ----1- (24)
L2
26
IEEE
ELECTRONICS TRANSFORMERS AND INDUCTORS Std 389-1996
These relationships are valid only where the coefficient of coupling is unity and the resistive components of
the winding impedances have the same ratio as the square of the turns ratio. They may also be used in equiv-
alent circuits.
The ratio of transformation of a practical transformer with a first winding having N1 turns to a second wind-
ing magnetically coupled to it and having N2 turns may be determined as the ratio of the impedances of the
two windings, including the mutual impedances:
Z 10 + K Z 10 ⋅ Z 20
a 12 = -------------------------------------------
- (25)
Z 20 + K Z 10 ⋅ Z 20
where
In the special case when the phase angles of Z10 and Z20 are equal, the ratio of transformation is equal to the
ratio of the inductances of the two windings, including the mutual inductances:
L 10 + K L 10 ⋅ L 20
a 12 = ------------------------------------------
- (26)
L 20 + K L 10 ⋅ L 20
where
The coefficient of coupling is the ratio of the impedance of the coupling to the square root of the product of
the total impedances of similar elements in the two meshes. In the case of transformers it refers to inductive
coupling:
M
K = ------------------------ (27)
L 10 ⋅ L 20
where
M is mutual inductance
27
IEEE
Std 389-1996 IEEE RECOMMENDED PRACTICE FOR TESTING
L sa – L so
K = --------------------------
- (28)
4 L 10 ⋅ L 20
where
The measurement of the ratio of transformation is performed under the conditions of 8.1.2; that is, the phase
angles of Z1 and Z2 are equalized. This may be accomplished by adding compensating resistance to one of
the windings until the difference between phase angles is eliminated, or by using a method where only the
impedance components that are in phase are compared. The two windings can be connected series aiding to
permit the current to pass through both, thus simplifying the equalization of phase. Then the voltages
appearing across the two windings can be accurately compared using potentiometric methods. The current
through the windings should be limited to where the core and copper losses are negligible.
R1 N 1
a 12 = ------ ≅ ------ (29)
R2 N 2
where
R2 is fixed bridge arm, with a value that is sufficiently high not to load the signal generator
significantly
R1 is precision variable resistor
Rc is compensating resistor
D is detector
28
IEEE
ELECTRONICS TRANSFORMERS AND INDUCTORS Std 389-1996
N1
a ≅ -------------------- (30)
N1 + N2
In this circuit the potentiometer of the bridge described in 8.2.1 is replaced by a precision inductive voltage
divider (ratio transformer).
The recommended method of connection is shown in figure 18. When the conditions of 8.1.1 apply, the ratio
of transformation may be determined from the ratio of voltages across the windings:
E1
a 12 ≅ ------ (31)
E2
This method may not indicate reverse polarity unless special precaution is taken.
Z 20 – Z 10
U = -------------------------------------------- ⋅ 100 (32)
Z 10 + K Z 10 ⋅ Z 20
where
29
IEEE
Std 389-1996 IEEE RECOMMENDED PRACTICE FOR TESTING
For the special case where the phase angles of Z10 and Z20 are equal, the impedances may be replaced with
the corresponding inductances, giving the inductance unbalance
L 20 – L 10
U = ------------------------------------------- ⋅ 100 (33)
L 10 + K L 10 ⋅ L 20
If N1 and N2 are the number of turns of the windings indicated by the corresponding subscripts, and if the
winding impedances are proportional to the squares of the turns in the respective windings, then
N 2( N 2 + K N 1)
- – 1 ⋅ 100
U = ----------------------------------- (34)
N 1( N 1 + K N 2)
For the special case when the coefficient of coupling K = 1, the inductance unbalance is
N2 – N1
U = ------------------- ⋅ 100 (35)
N1
The inductance unbalance between windings 1 and 2 may be expressed in terms of the ratio of transforma-
tion a12 between the windings:
U = ( a 12 – 1 ) ⋅ 100 (36)
The measurement of inductance unbalance may be accomplished with a bridge circuit as shown in figure 19,
where the resistors R1 are ratio-arm resistors and R2 is a calibrated ratio-arm potentiometer. The maximum
unbalance for which this bridge can be balanced is
R2
U max = ------ ⋅ 100 (37)
R1
The null-detector constraints for the ratio of transformation and inductance unbalance testing are as follows:
30
IEEE
ELECTRONICS TRANSFORMERS AND INDUCTORS Std 389-1996
c) Harmonic suppression. Sufficient to prevent errors or lack of precision due to the harmonics present
in the output signal of the bridge.
d) Input impedances. Input to ground impedances should be sufficiently large and so arranged that
errors due to stray currents will not be introduced. An impedance matching transformer with appro-
priate shielding may be used to match the bridge output to the detector input. The differential imped-
ance between the bridge output terminals is not critical since under null conditions both the voltage
and the current approach zero.
e) Phase-sensitive detectors. May be used to reduce the need for compensating resistance for windings
of differing phase angles. They will also reduce the time required to perform tests against minimum
or maximum limits.
8.4.1 General
The test circuits shown in figure 20 should be used where specified for determining the balance of the trans-
former windings. Matched resistors of the precision type should be used for the resistor pairs R1, R2, and R3,
R4. The sums R1 plus R2 and R3 plus R4 should equal, within 5%, the terminating impedance specified for
the associated windings.
The test may be made at any frequency, but frequencies near (1) the low-frequency 1 dB point, (2) the mid-
band frequency, and (3) the high-frequency 1 dB point should be used unless other frequencies are specified.
In general, at the low frequencies the elements contributing to unbalance will usually be winding resistance
and turns; in the middle frequencies, winding turns; and at the high frequencies, leakage inductances and
winding capacitances. The test is not limited to two-winding transformers, and the test circuit may be modi-
fied as required. For additional information on balance measurements see [B8].
Select the appropriate test circuit from figure 20, depending on the anticipated use. The various conditions of
grounding and the appropriate methods of testing are described in the table within figure 20. The accuracy of
measurement will depend on the ability to measure the voltage ratios with sufficient accuracy. Since for
good balance conditions the voltage ratio e4/e3 will be quite large, it is advantageous to use as high a voltage
as possible for the signal e3. This voltage is not limited by core loss since the energized windings are con-
nected flux opposition. Thus this voltage is limited only by the dielectric strength of the insulation between
windings and shield. The voltage e1 is applied directly to the winding (or windings); therefore it is necessary
to limit its level to the normal maximum operating level of the transformer. The impedance level of the sig-
nal source is of no importance since only the ratios of the voltages, namely, e2/e1 and e4/e3, are required. The
impedance of the voltmeter used for the measurement of e2 and e4 must be high compared to the termination
R3 [or R1 in figure 20 (g) and (h)] to avoid improper termination of the transformer under test. Since these
measurements will be sensitive to the values of termination, R1 through R4, it is essential that the resistance
terminations be those appropriate to the circuit in which the transformer is used, even though they might not
be the values that would produce the least in-band loss.
The polarity of a transformer winding is determined by the polarity of the voltage induced in the winding
with respect to a voltage applied to a reference or primary winding. For an alternating reference voltage the
winding is either in-phase (with near 0° phase shift) or out-of-phase (with near 180° phase shift) with the
primary or reference winding.
31
IEEE
Std 389-1996 IEEE RECOMMENDED PRACTICE FOR TESTING
NOTES
1—Winding with terminations R1 and R2 is the winding under test.
2—Test method I is the same as that for longitudinal balance; transformer balance is 6.02 dB greater than longi-
tudinal balance.
3—Where both windings are balanced, center tap C should be grounded or floating as required to simulate use
condition.
4—Where e1 = e3, balance = 20 log10 2e2/e4.
5—Ideally, e3 = –e4; only a small approximation gives balance ≅ 20 log10 e3/e4.
6—(a), (d), and (g) require a balanced source. If the transformer balance is 20 dB or better, an unbalanced gen-
erator may be used as in (b), (e), and (h) with less than 1 dB error.
7—In all cases, R1 = R2 and R3 = R4.
32
IEEE
ELECTRONICS TRANSFORMERS AND INDUCTORS Std 389-1996
Polarity tests for transformer windings may be combined with the ratio-of-transformation tests. The ratio
bridges in accordance with 8.2.1 and 8.2.2 will not balance properly due to the negative coefficient of cou-
pling when the windings are connected series opposing.
The relative winding polarities may be observed by using an oscilloscope to compare the phases of input and
output waveforms. The polarity of single pulses may also be detected by galvanometers or similar instru-
ments.
Since the induced voltages can be added as vectors, the winding polarities can be determined from voltage
measurements. For windings properly assembled with the shown polarity (figure 21),
E3 = E1 + E2 (38)
E3 = E1 – E2 (39)
9. Transformer capacitance
9.1 General
Transformer capacitance is the result of energizing the transformer. When the transformer is energized, dif-
ferent voltage gradients arise almost everywhere. In the pervasive electric field there are a large variety of
capacitances that correspond to each of these gradients:
— Between turns
— Between layers
— Between windings
— Between terminals
— Between the core and the end turn of a layer
— Between the core and each terminal
Only the lumped rather than the distributed parameter will be considered and only three capacitances (C12,
C22, and C11) will be used (see [B6]). The measuring techniques for the three capacitances are as follows.
Given a two-winding transformer [figure 22 (a)] whose equivalent circuits are as shown in figure 22 (b), and
transferring C12 and C22 to the left-hand side and eliminating the ideal transformer, we have the circuit
shown in figure 22 (c). Since the resistance has no effect in measuring the inductance and capacitance, the
circuit can be simplified further as shown in figure 23.
33
IEEE
Std 389-1996 IEEE RECOMMENDED PRACTICE FOR TESTING
The interwinding capacitance may be determined by connecting the shorted primary terminals and the
shorted secondary terminals, respectively, to the two unknown terminals of a capacitance bridge or digital
34
IEEE
ELECTRONICS TRANSFORMERS AND INDUCTORS Std 389-1996
LCR meter. The core, shield (if any), and additional secondaries should be appropriately guarded or con-
nected to ground in order to eliminate them from the measurement, as specified by the equipment manufac-
turer. Figure 24 shows a typical measurement setup. The measured values of interwinding capacitance can
vary with frequency or due to stray inductances. It is therefore recommended that, for design verification
purposes, more than one test frequency is used. For production testing, test frequencies below 10 kHz gener-
ally are chosen.
The distributed capacitance (or self-capacitance) may be determined by either of the following methods:
The distributed capacitance so measured is actually a lumped capacitance made up of multiple capacitances
all reflected to the particular winding under test. The separation of this one lumped capacitance into its con-
stituents is very difficult and is not within the scope of this recommended practice.
Figure 25 shows a measurement circuit with a transformer having a balanced primary, an unbalanced sec-
ondary, and an electrostatic shield.
The two terminals of the winding under test are connected to a digital LCR meter or equivalent. The test fre-
quency is varied until the winding impedance appears to be purely resistive. The distributed capacitance can
be calculated from the equation
35
IEEE
Std 389-1996 IEEE RECOMMENDED PRACTICE FOR TESTING
1
C dist = ---------------------
2
- (40)
2
4π f r L m
where Lm is the open-circuit inductance of the winding under test and ƒr is the resonant frequency.
NOTE—Lm usually varies with frequency and core flux density, so care should be taken to account for these effects.
The distributed capacitance can be measured on a digital LCR meter at a frequency where the phase angle
approaches –90°. In actual practice, phase angles less than –89° may be the best that can be achieved, in
which case the accuracy is suspect.
Another way to judge the best test frequency is to set it near the point of inflection (minimum capacitance) in
the curve of effective capacitance versus frequency.
Bridge methods can be used for transformer capacitances. Typical capacitance bridge circuits are shown in
figure 26.
10.1 General
Unless careful attention is paid to the measurement of impedance, serious inaccuracy may result. It is the
purpose of this clause to point out possible ways in which inductance and effective resistance or capacitance
and conductance may be represented and measured.
36
IEEE
ELECTRONICS TRANSFORMERS AND INDUCTORS Std 389-1996
In a wideband transformer, the core is usually of high-permeability material wound as a continuous strip or
with a very small air gap. Under these conditions the Q, or the ratio of effective series reactance to effective
series resistance, is small. Both inductances L and Q are dependent on the voltage level and frequency used.
Winding resistance ordinarily has a much smaller value than the core-loss equivalent series resistance in this
kind of transformer. Short-circuit inductance also is very small compared to mutual inductance. Therefore, it
is more representative of actual performance to regard open-circuit inductance Lsh and core-loss resistance
Rsh as parallel elements.
As frequency increases above the minimum, open-circuit reactance increases proportionately, so that at mid-
band and higher frequencies open-circuit reactance becomes so large as to be virtually negligible. Core-loss
resistance does not change nearly as fast with frequency. Both inductance Lsh and equivalent parallel resis-
tance Rsh are most significant at the lowest frequency, but at midband the open-circuit reactance may be ordi-
narily neglected, whereas the parallel equivalent resistance may contribute appreciably to midband
transformer loss. For the parallel representation, Q equals R sh ⁄ 2πf L sh . At any frequency it is possible to con-
vert from series to parallel equivalence by using the two expressions for Q. This conversion is unnecessary if
the proper bridge configuration is used.
Bridge measurements are applicable not only to measurements of high Q but also to open-circuit measure-
ments on low-score materials, capacitance between windings, low Q; to measurements on lossy materials,
and measurements of terminated impedance to determine the reflection coefficient. The accuracy of mea-
surement for each type can be optimized by the method in which the initial measurement or zero balance is
made.
As noted, the method in which the initial balance is made is of significance. Four appropriate methods are
listed in 10.2.1 through 10.2.4, depending on the type of measurement to be made. See figure 27 for typical
bridge circuits.
In order to obtain highest accuracy, it is necessary to use rather heavy straps from the bridge terminals to the
terminals of the apparatus. A shorting strap comparable in length to the distance between terminals of the
apparatus should be used and the straps to the bridge should be disturbed as little as possible.
L x = L1 – L0 + Lc
(41)
R x = R1 – R0 + Rc
where
Lc and Rc are corrections for the inductance and effective resistance of the strap. The value of the strap
inductance Lc is given by
37
IEEE
Std 389-1996 IEEE RECOMMENDED PRACTICE FOR TESTING
38
IEEE
ELECTRONICS TRANSFORMERS AND INDUCTORS Std 389-1996
where
R c = R dc = [ l + 28.5 f 2 d 4 ⋅ 10 6 ] (43)
39
IEEE
Std 389-1996 IEEE RECOMMENDED PRACTICE FOR TESTING
where
NOTE—This method may also be used for high impedance, in which case the correction terms may be negligible.
This method is applicable for terminated measurements to determine the reflection coefficient when the
impedance to be measured is essentially resistive. In place of the shorting strap used in the method described
in 10.2.1, a noninductive, low-capacitance resistor of value as close as possible to the ideal nominal value
looking into the terminals of the apparatus is selected. If the resistor has low parasitic inductance and capac-
itance, the impedance being measured may be determined from the formulas
Rx = R2 – Ra + RR
(44)
Lx = L2 – La + LR
where
To avoid errors when connecting the bridge to the apparatus under test, fairly rigid leads should be used. The
grounded terminal of the bridge should be connected to the ground terminal of the apparatus to be measured,
and the high terminal lead should be near but not touching the terminal or terminals of the apparatus. The
value of impedance is then merely the difference between the zero (open) measurement and the value
measured with the terminals of the apparatus connected to the bridge (corrected in accordance with the
bridge instructions where necessary). If a balanced to ground or direct capacitance measurement is to be
made, only the grounded terminal of the apparatus should be connected to the grounded terminal of the
bridge for the zero or open-circuit measurement with both high-potential terminals of the apparatus.
A parallel bridge may also be used for terminated impedance measurements as in the method described in
10.2.2. As before, a low-capacitance, low-inductance resistor should be used for the zero measurement. For
this case the admittance being measured may be determined from the formulas
Rp = R3 – RB + RR
(45)
Cp = C3 – CB + CR
where
40
IEEE
ELECTRONICS TRANSFORMERS AND INDUCTORS Std 389-1996
When transformers are designed to operate over a fairly wide range of frequencies and serve the function(s)
of matching a load to a power source with a linear response over that range, to provide voltage isolation
between source and load, or to provide rejection of common-mode voltages between source and load, such
transformers are usually tested to determine their frequency response characteristic over a specified range
when operated in an amplifier circuit for which they were designed. Also, where transformers are used in
control systems, the transformer frequency response is often valuable in evaluating the stability and other
dynamic properties of the control system.
The frequency response of a simple two-winding transformer can be measured in a relatively simple circuit
consisting of a variable frequency low-impedance sine-wave source of low harmonic content, a linear and
noninductive load resistor of a value equal to the rated secondary load resistance, a linear capacitor equal in
capacitance to the rated load shunt capacitance, and a linear noninductive resistor in series between the vari-
able-frequency source and the transformer primary, which is equal in value to the internal resistance of the
power source from which the transformer under test is designed to operate. Figure 28 shows such a test
circuit.
The voltage and power levels used to make frequency response tests should never exceed the rated values of
the transformer. Voltage and power levels less than rated values may be used, but they should not be less than
about 1% power (10% voltage) at the low-frequency end of the rated frequency range in order to avoid the
effects of low initial permeability of core materials. Also, a full voltage test at the lowest rated frequency
should be included to ensure that core saturation is not a problem.
If the primary (or secondary, or both) is required to carry unbalanced components of direct current, means
should be provided to inject the required values of direct current into the windings. Figure 29 shows one
method of accomplishing this.
41
IEEE
Std 389-1996 IEEE RECOMMENDED PRACTICE FOR TESTING
In figure 29 the direct-current supply voltage Edc is chosen to be high enough to supply a sufficient bias cur-
rent to primary P when the resistance of Rb1 is made high enough that it will not unduly load the variable-
frequency generator FG. Capacitor C1 should have negligible reactance at the lowest test frequency. If the
secondary winding must carry a direct current, the value of Edc must be high enough to supply the required
bias current through the secondary winding resistance plus the load resistance. Capacitor C2 should have a
low reactance at the lowest test frequency relative to the resistance of RL. Capacitor C2 is required if voltme-
ter VL has no internal blocking capacitor. The frequency response of a single-ended to push-pull transformer
should include separate response curves for each half-secondary winding to show the extent, if any, of differ-
ences in response at the high-frequency end of the response curves. Differences in response at that end of the
characteristic may be due to differences in capacitance couplings from the primary to each half-secondary or
differences in leakage inductances from the primary to each half-secondary, or both.
Likewise, for push-pull to single-ended transformers, frequency response tests include tests made with first
one half-primary excited and then the other half-primary excited for the same reasons as given for single-
ended to push-pull transformers. These frequency response tests are in addition to tests of the frequency
response with 180° out-of-phase balanced input voltages to the two primary windings. Separate resistors
should be used to simulate the driver internal resistances. Here again, if negative feedback from the second-
ary of 10 dB or more is provided in the circuit in which the transformer is to be used, the internal resistance
of the driver stage is thereby made so low that it can be neglected in a test circuit.
When the driver stage is of the push-pull amplifier type known as class AB or is a class B amplifier, the vari-
able-frequency generator circuit should be modified to simulate the type of amplifier stage in which the
transformer is to be used. A class B type amplifier may be simulated by inserting a diode in series with each
resistor, which simulates the internal resistance of the driver stage. The rectifier polarities should be the same
as they would be to form a full-wave rectifier circuit. For class AB operation without negative feedback from
the output terminals, the combination of the diodes and a direct-voltage bias may be used to simulate the
driver amplifier. However, if the application is a class AB amplifier with negative feedback from the output
terminals, the best way to make frequency response tests is to use a low-power-level amplifier of approxi-
mately one-tenth the voltage output of the rated amplifier for the high-frequency response tests and then rely
upon the single-ended response tests at rated power for determining any core saturation effects at the lowest
rated operating frequency.
An alternate method of measuring transformer response is by using the circuit shown in figure 30.
NOTE—By keeping the generator voltage constant when the frequency varies, the generator impedance is not critical.
Also, to eliminate voltmeter errors, it is recommended that the same voltmeter for E and Vout readings is used.
To measure the transformer loss, also referred to as insertion loss at fm (figure 31), set the generator level E
at a convenient decibel value and then switch the voltmeter to read Vout:
E RL
transformer loss at fm = 20 log --------- + 10 log --------- [dB]
V out 4 Rg
42
IEEE
ELECTRONICS TRANSFORMERS AND INDUCTORS Std 389-1996
To measure transformer loss at any other frequency with respect to the loss at frequency fm, set Vout at a con-
venient voltage reference, switch voltmeter to check generator voltage E, then change frequency and adjust
generator voltage for the voltage reading E. Switch voltmeter to the output of the transformer and read the
voltage V´out. The transformer response at that frequency is the difference between Vout and V´out, or
V out
response = 20 log ----------
- [dB]
V ′ out
When conducting all frequency-response tests, an oscilloscope should be used to observe the waveform of
the output (secondary) voltage across the load. Any distortion of this voltage wave should be noted. The
frequency at the high-frequency end and that at the low-frequency end at which the distortion sets in should
be recorded.
If the phase angle of the output (load) voltage with respect to the input (generator) voltage is required, an X-
Y oscilloscope display may be used to obtain data for plotting a curve of frequency versus phase perfor-
mance of the transformer in the amplifier circuit for which it is designed to operate.
When transformers are designed to operate between a source of pulse voltages and a load, they should be
designed to be capable of operating over a wide range of frequencies, but they are usually tested in the time-
domain mode, i.e., by determining their pulse responses, as this kind of information is most useful to the sys-
tem designers. Pulse transformers may perform one or more of the following functions:
For more detailed evaluation of pulse transformers and of magnetic materials under pulsed excitation,
consult IEEE Std 390-1987 and IEEE Std 393-1991.
Although much information regarding the ability of a pulse transformer to provide its rated performance in a
specified system can be had by low-level tests in a circuit simulating the operations conditions, a final evalu-
ation of the design and construction may require a full-scale test in the system in which it is to be used. The
performance of the pulse transformer is evaluated by displaying the output (secondary) voltage of the trans-
former under rated load and driven by a specified power source. In those applications where the nonlinearity
of the load impedance versus voltage curve exerts a large effect upon the waveshape of the output voltage,
the load versus current waveshape should also be displayed. The test results consist of photographic record-
ings of the calibrated oscilloscope display or curves plotted point by point from that display.
43
IEEE
Std 389-1996 IEEE RECOMMENDED PRACTICE FOR TESTING
Pulse transformers usually are driven by either a so-called hard-tube type pulse generator (amplifier), which
also includes transistor-type amplifiers, or by a delay-line type pulse generator consisting of a pulse-forming
network in which energy is stored during the interpulse period and discharged into the primary of the pulse
transformer during the power pulse period through an electronic switch such as a thyratron or a thyristor.
The load on a pulse transformer may be the control element of an electronic device such as an electron tube
grid, a transistor base, a thyristor gate, a magnetron, a klystron, a traveling wave tube, an amplitron, or an
X-ray tube. All those listed require a unidirectional pulse voltage and many have negative-slope impedance
versus voltage characteristics; i.e., as the voltage impressed upon them increases, the load impedance they
present to the transformer secondary decreases.
For the purposes of low-level testing of pulse transformers, the pulse generator can be simulated by a unidi-
rectional pulse generator of low internal impedance, the rise time of which can be controlled from a fast rise
time of about 20 ns over a range to a slower rise time of about 1 µs, or even longer for long-pulse applica-
tions. The overshoot of the rise time should be less than 2%. The top of the pulse should be flat with a ripple
and droop of less than 0.5%. The pulse width should be continuously adjustable from 0.1 µs to 100 µs. The
pulse output voltage should be at least 10 V into a 50 Ω load and preferably 50 V into a 50 Ω load. The fall
time at the end of the pulse should be no more than double the rise time. The rated internal resistance of the
system generator is then simulated by a series resistor between the test generator and the transformer pri-
mary. A fast-recovery diode in series with this resistor is required to simulate hard-tube and transistor-type
pulse generators.
The various characteristics of loads into which pulse transformers operate can be simulated reasonably well
at low levels by a shunt capacitor, a fast-recovery diode in series with a noninductive linear resistor, and, for
magnetrons and negative-biased vacuum tube grids, a direct voltage bias supply.
Figure 32 depicts a low-level pulse response test circuit. Here diode DG would be used to simulate a hard-
tube or transistor-type switch, and for that type of pulse generator RG is relatively low and is determined by
the voltage-saturation portion of the switch device. For a so-called line-type pulse generator, resistor RG is
made equal to the characteristic impedance Z0 of the pulse-forming network.
Referring again to figure 32, but to the simulated load portion, RI is a noninductive resistor of the order of
0.1 Ω for supplying a voltage to the current trace of the oscilloscope. Capacitor CL represents the shunt
capacitance of the rated load device. Diode DL simulates the rectifying properties of most pulse-type loads.
Resistor RL simulates the dynamic resistance of the load during the pulse. To simulate a magnetron of a
biased-off grid load, the direct voltage Edc represents the knee (Hartree) voltage of the magnetron or the grid
bias voltage of an amplifier tube.
44
IEEE
ELECTRONICS TRANSFORMERS AND INDUCTORS Std 389-1996
Low-level pulse tests using simulated pulse generator characteristics and load characteristics are quite accu-
rate for measuring the rise time, overshoot, and ripple of the pulse voltage supplied to the load at full power
levels. However, for determining the voltage droop, pulse fall time, and back-swing characteristics, the non-
linearity of the magnetization characteristics of low pulse voltage levels are not the same as they are at high
voltage levels, hence low-level tests for those characteristics may be subject to substantial errors.
The transformers shall be mounted in an enclosure having a sound level of at least 4 dB, and preferably 7 dB
or more, lower than the sound level of the transformer and the ambient combined. The ambient sound level
shall be the average of the measurements taken immediately before and immediately after the transformer is
tested at each of the locations as indicated in 12.2 item b). Corrections shall be applied in accordance with
table 3.
The enclosure should be free of any noise-reflecting surface. Whenever possible, the transformer should
be bolted on the chassis or other mechanical structures on which it is to be permanently mounted during
operation.
The transformer is to be energized at rated voltage and frequency, and at full load or with no load as
specified.
a) Sound levels shall be measured with an instrument that is in accordance with ANSI S1.4-1983.
Response curve A (for 40 dB sound level) shall be used.
b) Measurements shall be taken with the probe of the sound-level meter located not more than 30 cm
from the surface being measured. The readings shall be taken at the center of each of the vertical
planes of the transformer and at the center of the top horizontal plane.
c) The average sound level is defined as the arithmetic mean of the sound levels measured according
to item b).
45
IEEE
Std 389-1996 IEEE RECOMMENDED PRACTICE FOR TESTING
d) Electromagnetic interference (EMI) testing shall be performed on the total system utilizing a
transformer or inductor, and cannot be effectively performed on a transformer or inductor as a
component.
13.1 General
Terminated impedance measurements may be required when it is necessary to limit reflections on a trans-
mission line to a minimum value. The degree of mismatch is given in terms of the reflection coefficient
between the impedance of the line and the impedance looking into the transformer when it is terminated in
its nominal termination. The reflection coefficient may be determined from series impedance measurements,
from parallel measurements using an appropriate impedance bridge, or by means of return-loss measure-
ments described in 13.2.
A rapid and convenient method of making return-loss or reflection coefficient measurements requires an
appropriate return-loss bridge. The bridge may take the form of the examples shown in figure 33.
To obtain highest accuracy, an impedance match should exist at each port except for the unknown port. The
output voltage at the detector is directly related to the mismatch and therefore the reflection coefficient at
this port.
The two-core hybrid bridge of figure 33 (b) is the most complex but permits matching of arbitrary imped-
ance at input, detector, standard, and unknown ports. The single-core hybrid bridge of figure 33 (c) permits
matching of arbitrary impedances at input and at standard and unknown ports. Unless an additional trans-
former is used at the detector port, the detector impedance should be half the standard impedance. In the
resistance bridge of figure 33 (d) and the reflectometer of figure 33 (e) the balance is derived from the resis-
tors of the resistance bridge rather than the balance of the transformer. The transformers in the latter two
cases are unbalanced-to-balanced devices to permit grounding both the signal source and the detector. In the
case of the resistance bridge, the transformer permits arbitrary match at the input. The reflectometer requires
equal impedance at all ports.
The test method is similar for all devices of figure 33. Figure 34 shows that the test procedure requires four
transmission voltage ratios to be measured at each test frequency.
Let
E0
T 1 = 20 log ------ [dB] for position 1
E1
(46)
E0
T 2 = 20 log ------ [dB] for position 2
E1
1 (T + T ) 2
For a resistive bridge or resistance reflectometer the average, T 0 = ----------------------- , will be approximately 12 dB if
2
the value Rs is the design value and will be greater as R2 deviates from the ideal value.
46
IEEE
ELECTRONICS TRANSFORMERS AND INDUCTORS Std 389-1996
For hybrid transformer bridge, T0 will be about 6 dB ideally, and will also increase as Rs is changed from the
design value. T3 in position 3 is a check measurement to test the balance of the bridge. The difference
( T 3 – T 0 ) is a measure of the precision of the bridge. This difference should be 20 dB greater than the
requirement of return loss imposed on the transformer to obtain a reasonable accuracy of measurement.
T4 is obtained when the transformer under test is connected to the “unknown” terminal of the bridge. The
return loss RL is given by
RL = T 4 = T 0 [dB] (47)
for the case where R1, R2, and Rs are the values for which the bridge was designed.
It is possible to obtain satisfactory accuracy in certain cases merely by measuring the output voltage E0,
which for the four conditions will be designated e1, e2, e3, and e4. The voltage e0 corresponds to T0 in the
preceding case and is determined from the formula
e0 = e1 e2 (48)
47
IEEE
Std 389-1996 IEEE RECOMMENDED PRACTICE FOR TESTING
e
e3 provides a test of the bridge and should always be no greater than ----4- . The return loss RL is given by
2
e0
RL = 20 log ---- [dB] (49)
e4
NOTE—Errors will always be in the direction to show optimistic values of return loss.
The error will be on the order of ( T 2 – T 1 ) ⁄ 2 due to mismatch and will vary from approximately 1 dB if the
balance of the bridge is 20 dB better than that measured from the transformer, to 6 dB if the bridge balance
is equal to the balance of the transformer.
The maximum temperature rise of transformers or inductors can be measured by imbedding a thermocouple
in the center of the coil and measuring the temperature with a thermocouple meter.
If it is not possible to insert a thermocouple in the coil, the temperature rise can be determined by measuring
the resistance change of the inside winding coil.
Since the resistance of conductor materials changes with temperature, the resistance of the coil winding will
change with temperature.
When thermal stability is achieved, disconnect the power source and load, and measure final (hot) dc resis-
tance of the winding.
NOTE—Thermal stability can be defined to occur when two consecutive measurements of winding temperature, taken
30 min apart, are the same, within 1 °C.
48
IEEE
ELECTRONICS TRANSFORMERS AND INDUCTORS Std 389-1996
To determine the mean temperature rise of the coil winding, use the equation
Rh – Rc
T r = ----------------- ( T s + K ) – ( T f – T s ) (50)
Rc
where
Since it is difficult to measure the resistance of a winding while power is still applied to that winding, several
resistance measurements shall be made after power interruption at predetermined time intervals to determine
the resistance at zero time, Rh, as, for example, shown in figure 35. For further information, see IEEE Std
119-1974.
Temperature rise can be measured without interruption of power by installing a bifilar winding (usually on a
single layer), inside the coil. The bifilar winding is connected in series opposition, so that induced voltages
cancel.
This permits continuous monitoring of the “hot” dc resistance while the transformer is under load.
NOTE—In small high-frequency transformers, two problems can arise, resulting from noise pickup, or from a change in
the apparent resistance of the sense winding. Errors in the temperature calculation can therefore be avoided by momen-
tarily turning off power while taking readings of the “hot” value of resistance.
In the case of natural convection, the transformer should be tested in an area free from drafts. Where practi-
cal, ambient temperature should be measured in close proximity to the surface of the transformer (typically
15–30 cm from its surface). In general, the rise in ambient, Tf – Ts, should not exceed 5 °C, which can help
increase the accuracy of the final calculation of temperature rise. The test document should record the exact
location of where the ambient temperature was measured.
In many instances, an accurate measurement of temperature rise will depend on a close simulation of the
physical environment of the inductive component. This can be especially important in a high-frequency
power supply that operates at high levels of power density (rated watts per unit volume).
In the case of forced convection, tests should be performed under conditions that simulate the layout of com-
ponents and with the specified rate of air flow.
49
IEEE
Std 389-1996 IEEE RECOMMENDED PRACTICE FOR TESTING
In the case of conductive heat transfer, it is desirable that the ambient temperature be measured in a region of
the heat sink (e.g., base-plate of chassis) that is in close proximity to the mounting area of the transformer.
14.2.3 Thermocouples
Great care should be taken in the method of attaching a thermocouple to a region inside a coil or to a surface.
To ensure repeatability of measurements, strive to minimize thermal resistance by obtaining intimate contact
at the interface. The test documents should state the exact location of each thermocouple, as well as the tech-
nique used in attaching the thermocouple to the surface.
CAUTION
The best thermocouple attachment is often with minimal insulation; therefore, a
large voltage difference may exist between multiple thermocouples or to ground,
creating a possible shock hazard.
NOTE—The magnetic field of the transformer can induce eddy currents in a thermocouple, and thereby add undesirable
parasitic losses. Precautions should therefore be taken to determine that the size and material of the thermocouple do not
introduce an unacceptable error in the temperature reading.
Substantial errors in temperature rise measurements can be introduced by the attachment of leads to a wind-
ing that has very low resistance (in the order of milliohms). Avoid the use of alligator clips, which are often
responsible for a variation in contact resistance, and can make it difficult to repeat measurements of the tem-
perature rise. Keep exterior leads short. Be sure to subtract the resistance of lead wire, so as to establish the
actual resistance of a winding.
15. Self-resonance
15.1 General
Self-resonance in a transformer or inductor results from the interactions of the various distributed self-induc-
tances and capacitances normally present due to its physical construction. An examination of the midband
and high-frequency equivalent circuits will show that there are several possible self-resonance conditions,
either series or parallel resonance. Of particular concern are those within the frequency band covered by the
device’s application, although in some cases out-of-band self-resonances can cause parasitic damped oscilla-
tions or other effects. Self-resonance may manifest itself in a wideband transformer as an irregularity in fre-
quency response or reflected impedance, or in a wave-filter inductor as an undesired response characteristic.
15.2 Measurement
Self-resonance in an inductive device is indicated by a peak in impedance for a parallel resonance and by a
dip in impedance for a series resonance. While the usual means of measuring impedance described in
clause 13 may be used, they are cumbersome to use in determining frequency of resonance. The technique
described in this clause lends itself to a quick determination of self-resonant frequencies.
Commercial equipment is available giving a direct reading of impedance as well as impedance angle using
techniques similar to that described here. In most cases, however, only the type of self-resonance and the
frequency at which it occurs is needed to determine the probable cause or causes. The technique to be
described should be adequate for most situations.
50
IEEE
ELECTRONICS TRANSFORMERS AND INDUCTORS Std 389-1996
The technique shown in figure 36 consists of monitoring the voltage across the device in an essentially
constant-current circuit for maxima and minima in voltage as frequency is varied. While the technique does
not necessarily apply the normal working voltage across the device, this should cause little problem
provided that the device is operating in a nonsaturated state.
The circuit in figure 36 utilizes an oscillator capable of covering the frequency range of interest and having
an output voltage sufficient to provide readable voltages on the voltmeter at the minimum frequency of inter-
est. The total of the source resistance of the oscillator in series with external resistor R1 should be about 50
times the highest expected value of the open-circuit impedance of the device. The frequency is varied, so
there is a need to watch for changes in direction of meter deflection. A maximum in voltage indicates a
parallel resonance; a minimum indicates a series resonance. The types of resonances and the frequencies at
which they occur should be noted.
The approximate impedance can be calculated using the following formula (the error will increase as Z
approaches R1):
V z
Z ≈ ------1 ⋅ R 1 for R 1 ≥ 50 Z gen (51)
V R
16.1 General
The voltage-time product rating of a magnetic component is intended as an aid in pulse power conversion
applications.
The voltage-time product is often determined by observing the pulse-exciting current on an oscilloscope or
recorder. In that case, the voltage-time product of a winding is specified as the maximum voltage-time inte-
gral of a rectangular voltage pulse that can be applied to the winding before core-saturation effects cause the
resultant exciting-current pulse waveform to deviate from a linear ramp by a given percentage (see 16.2).
Generally, the applied pulse-voltage amplitude shall be that used in 11.2. It shall not exceed the test voltage
used in the induced voltage electric strength test (see 5.3), and the pulse-repetition frequency shall be kept
sufficiently low to prevent transformer heating that could affect the magnetic characteristics or damage the
transformer. The recommended pulse duration for the determination of this rating is that for which the trans-
former was designed. The voltage-time product does not remain constant when the pulse duration is very
short. If the transformer application involves a direct current in any of the windings, the measurement shall
be made with rated direct current ampere turns and polarity applied through a suitable impedance to prevent
pulse-loading effects. Input pulse source impedance and pulse parameters shall be specified for this test. The
preferred test method is described in 11.2.
51
IEEE
Std 389-1996 IEEE RECOMMENDED PRACTICE FOR TESTING
16.2.1 Rectangular voltage pulse applied from low-impedance source, and pulse-exciting
current response observed
NOTE—This test method is nearly the same as the recommended test method for open-circuit parameters (magnetizing
pulse inductance and exciting current) normally used for pulse transformers.
The voltage-time product of a winding shall be measured as the product of the pulse-voltage amplitude of a
rectangular voltage pulse applied to the winding and the pulse duration measured at a time t2 where the
resultant pulse-exciting current has increased to a certain value that is a specified percentage (e.g., 50%)
above the linearly extrapolated value of the linear ramp waveform. The departure of the exciting-current
waveform from a linear ramp is due to a rapid decrease in magnetizing pulse inductance as the core flux
reaches the saturation region (figure 37).
The droop of the applied voltage pulse shall be less than 2%.
An example of a recommended test circuit for rectangular pulse excitation is shown in figure 38. In general,
a pulse source simulating the circuit in which the transformer will be used shall be employed in the test
setup.
L is isolation inductor
C is bypass capacitor
T is current probe
Vp is adjusted to required transformer primary voltage
52
IEEE
ELECTRONICS TRANSFORMERS AND INDUCTORS Std 389-1996
17. Shielding
17.1.1 Symbols
The basic electrostatic symbol is shown in figure 39. Other possible variations of shield configurations are
shown in figures 40 through 45.
53
IEEE
Std 389-1996 IEEE RECOMMENDED PRACTICE FOR TESTING
54
IEEE
ELECTRONICS TRANSFORMERS AND INDUCTORS Std 389-1996
A typical two-winding shielded transformer may be represented as shown in figure 46, where the capaci-
tance has been “lumped” at the center of each winding, and the core has been omitted for clarity. C1 and C2
are the capacitances between the shield and the primary and the secondary, respectively, and Cd is the direct
interwinding capacitance. The representation may be further simplified as shown in figure 47.
The purpose of electrostatic shielding of transformers is to minimize the effect of Cd, the direct interwinding
capacitance, since it is via this capacitance that unwanted signals are coupled between windings.
The degree of shielding obtained depends on how the shields are incorporated in the transformer and how
they are connected in the circuit.
Multiple shielding may be used to isolate specific capacitances to a particular point or points in the circuit in
addition to limiting common-mode coupling. This will provide some “control” of these stray capacitances
that may be effective in particular applications.
The effectiveness of shielding is generally described in terms of direct capacitance between windings, or as
attenuation in decibels of unwanted signals. When measuring transformers for common-mode rejection, it is
advisable to simulate the circuit in which the transformer is intended to be used.
55
IEEE
Std 389-1996 IEEE RECOMMENDED PRACTICE FOR TESTING
V
C d = ------------ (52)
ωRE
where
V is coupled voltage
ω is frequency of generator, in radians per second
R is load resistor (including voltmeter loading)
E is generator voltage
If, for example, ω = 105 (f = 15.9 kHz), E = 100 V, and R = 10 kΩ, then a V of 1 mV corresponds to a Cd of
0.01 pF.
In practice there is a shunt capacitance Cs across R, and a shunt resistance Ri across Cd. Given the values
stated above, Cs may be as high as 100 pF. If Ri = 1010 Ω minimum, the system will measure values of Cd
between 0.01 pF and 100 pF.
An alternate method, which may be used for measuring values of Cd above 1 pF, is direct reading with a
three-terminal capacitance meter. The shield is connected to ground and the windings in question to high and
low.
— Stray capacitances and sensitivity limit applicability to direct (coupling) capacitance above 1 pF
— Grounded winding with floating core may be awkward to implement mechanically
NOTE—Either of the test methods may be used to obtain the ratio of capacitance with and without shield by adding a
switch in the shield lead:
C shield floating
RSE = ----------------------------------------------
C shield connected
56
IEEE
ELECTRONICS TRANSFORMERS AND INDUCTORS Std 389-1996
Magnetic shielding is specified as required either to reduce a magnetic flux field emanating from a trans-
former (or inductor) or to reduce a magnetic flux field entering a transformer (or inductor). Magnetic shield-
ing is utilized, when needed, for magnetic flux with a frequency in the range of zero to approximately
10 kHz.
When an emanating flux is being reduced, the specification should define the maximum flux-density in
millitesla (or in gauss) adjacent to any surface of the device at a specified distance. The flux-density level can
be measured with a high-impedance detector (greater than or equal to 10 MΩ input impedance) and a mag-
netic search coil type of pickup probe (see annex C for description) or with a Hall-effect type gaussmeter.
Because the flux emanating from the transformer (or inductor) may not be perpendicular to its surface, the
flux measuring device (or the transformer or inductor) should be rotated to obtain the point of maximum
emanating flux. If the magnetic shield is removable, the above technique may be utilized to determine the
magnetic shield effectiveness by comparing measurements with and without the magnetic shield in place. If
the transformer or inductor under test normally is operated with a direct current flowing in a winding, the
test should be performed with that current flowing.
If an external magnetic flux entering the transformer (or inductor) is to be reduced by magnetic shielding,
the shielding specification relative to the specific component may define either item a) or b):
a) Specify the reduction in decibels that the magnetic shielding gives at a specified flux density at a
specified frequency or frequency range. Tests of the shield effectiveness may be made on a sample of
the transformer made with its magnetic shielding and an identical sample made without its magnetic
shielding. A high-impedance voltmeter is connected to the highest voltage or highest impedance
winding of the transformer (or inductor) while that transformer (or inductor) is slowly rotated
through the specified magnetic field until a maximum is observed. The ratio of the maximum voltage
reading without shielding to the maximum voltage reading with shielding is a measure of the mag-
netic shielding effectiveness. The reduction may be stated in decibels by the formula
E ns
dB = 20 log -------
- (53)
E ws
where
b) Specify the maximum voltage reading when a high-impedance voltmeter is connected to the highest
voltage or highest impedance winding of the transformer under test while the device is slowly
rotated in the specified magnetic field.
18.1 Definition
The quality factor Q equals 2 π times the ratio of the maximum stored energy to the energy dissipated per
cycle at a given frequency. This can be shown to be equal to ωL s ⁄ R s for a coil represented as an inductance
Ls in series with a resistor Rs, or Rp/ ω Lp for a coil represented as an inductance Lp in parallel with a resis-
tance Rp. The quality factor values vary from less than 1 to more than 1000.
57
IEEE
Std 389-1996 IEEE RECOMMENDED PRACTICE FOR TESTING
18.2 Methods
— Bridge measurements
— Q-meter measurements
— Insertion-loss measurements
— Transmission method
— Damped-oscillation method
— Vector voltmeter measurements
Measurements made on “bridges” are impedance measurements where the real and imaginary parts of the
impedance are given or calculable from the values of the bridge arms when the bridge is balanced. As noted
in the definition, the ratio of the real and imaginary portions of the impedance or vice versa, depending upon
whether the impedance is in series or parallel form, gives the value of Q, so that the bridge in its various
configurations is ideally suited for making measurements of Q ≤ 50. In general, many commercial bridges
with configurations as outlined in clause 10 allow Q measurements to be made with up to a few volts across
the inductor or transformer. In some cases this may restrict the flux-density level in the core to some low
value (< 100 gauss). The various types of ac bridges differ only in the types of impedance standards used and
in the relative positions in the bridge arms of the standards and the unknown impedance. Some usual bridge
arrangements are shown in figure 27, which also gives the balance conditions in each case. The resonant
bridge of figure 27(f) differs from the others in that the balance depends critically on the testing frequency,
which has to be controlled to a greater degree of accuracy than is necessary for the nonresonant types. The
bridge circuit of figure 27(f) is useful since it enables both the resistive and the inductive portions of the
unknown impedance to be measured in terms of differences in the settings of the variable capacitors and
while all the resistances are fixed. This is an advantage at high frequencies where an air dielectric capacitor
forms a more satisfactory impedance standard than a variable resistor. This is a substitution bridge in which
an initial balance is made with the “unknown” terminals short-circuited and the bridge balanced again with
the unknown impedance inserted. The choice of the best bridge to be used for a given purpose depends upon
the frequency range and the range of inductance and Q values that are to be measured.
NOTE—The balance of the bridge arms should be obtained at a specified voltage across, or at a specific current through,
the device under test.
This instrument gives a direct reading of the Q of a coil or transformer. The winding under test is connected
in series with a variable capacitor that forms the impedance standard. A known alternating voltage at the test
frequency is applied across the tuned circuit (made up of the test winding and the variable capacitor), and the
circuit is adjusted to resonance as indicated by a maximum reading on a voltmeter that is connected across
the capacitor. The impedance of the capacitor will be almost a pure reactance that, at resonance, is numeri-
cally equal to that of the test coil. The ratio of the modulus of the voltage across the capacitor to that of the
applied EMF to the circuit is thus ωL ⁄ R + R s where Rs is the equivalent series-loss resistance of the capacitor.
If Rs is negligibly small, then the ratio of voltages gives the Q of the winding under test. Since the method
relies on the peaking of the voltage across the capacitor at resonance, two basic points are worth noting:
(1) Q of less than 10 are barely detected and (2) Q of 1000 can produce up to 10 V across the test winding;
this may result in relatively high flux densities in small cores. Commercial instruments are available with the
generator, variable capacitor, and detector in a single box, and the arrangement of dials and indicators makes
them quick and easy to use. The frequency range is 50 kHz to 50 MHz for one model and 20 MHz to
200 MHz for another. A low-frequency adapter device is available to extend Q measurements down to
1 kHz. A circuit diagram is shown in figure 49.
58
IEEE
ELECTRONICS TRANSFORMERS AND INDUCTORS Std 389-1996
In the instruments mentioned, the voltage applied to the circuit is held constant at 10 mV (times 1 range),
20 mV (times 2 range), etc. For a Q of 100, the voltage across the coil is then 1 V or 2 V, depending on the
range of Q selected. The output reading of the voltmeter is calibrated directly in values of Q.
The inductor to be measured is combined with a high-quality capacitor to form an LC circuit resonating at
the measuring frequency. The effective resistance at resonance is measured by determining the attenuation of
a transmission path containing the resonant circuit. The quality factor is calculated from this resistance and
the reactance of the inductor measured under identical conditions, taking into account the losses due to cir-
cuit components.
The generator G is variable in frequency and voltage. The resistance of each of the two resistors R1 and R′1
is equal to the characteristic resistance of the attenuator. Resistance R2 is approximately twice the effective
series resistance Rx of the resonant circuit (which must be estimated in advance), or 5 Ω, whichever is
greater. The attenuator shall be able to resolve 0.1 dB with sufficient accuracy. The accuracy of this method
depends mainly on the accuracy of the attenuator.
Voltmeter V1 is a high-impedance ac voltmeter, and voltmeter V2 is a tuned detector having an input imped-
ance very much greater than R1 and R2.
59
IEEE
Std 389-1996 IEEE RECOMMENDED PRACTICE FOR TESTING
With switch S1 closed, the frequency of the generator is adjusted to the resonant frequency of the LC circuit
as indicated by maximum deflection of V1.
If the frequency is then not sufficiently close to the specified measuring frequency, the capacitance of capac-
itor C shall be changed until the circuit resonates at the required frequency. The voltage of the generator
shall be so adjusted to a reasonable value. The frequency is then readjusted to resonance if necessary and
switch S1 is opened. With switch S2 in position B, the tuning of detector V2 is adjusted for maximum
deflection. The capacitor C is then returned for minimum deflection of V2 (to compensate the opening of
S1). The attenuator is adjusted until the detector indication is the same for either position of switch S2. The
attenuator setting α (in decibels) is noted.
18.5.3 Calculation
ωL ωL
Q LC = ------- = ------- ( 2 ⋅ 10 α ⁄ 20 – 1 ) (54)
RX R2
where
Corrections for capacitor loss and for self-capacitance of the inductor are
Q LC Q C 2C
Q L = ----------------------- 1 + ---------s (55)
Q C – Q LC C
where
The inductor to be measured is combined with a high-quality capacitor to form an LC circuit resonating at
the measuring frequency. A pulse train is applied to this circuit, and the voltage across the inductor between
the pulses is displayed on a calibrated oscilloscope. The quality factor of the inductor is calculated from the
voltage ratio occurring at a certain time interval as measured on the oscilloscope, taking into account the
losses due to circuit components (figure 51).
18.6.1 Accuracy
An accuracy of ±4% can be obtained provided the corrections for probe resistance and capacitor loss are
relatively small.
60
IEEE
ELECTRONICS TRANSFORMERS AND INDUCTORS Std 389-1996
18.6.2 Generators
The frequency range shall coincide with the frequencies at which measurement shall be made. The open-
circuit output voltage shall be adjustable between 0 V and 10 V.
The pulse width shall be between 10 µs and 100 µs, and it shall be possible to set the repetition rate at a
value between 500 and 300 pulses per second. The open-circuit output voltage may, for example, be 100 V.
18.6.2.3 Antenna
The generators are coupled with the LC circuit by means of a wire placed approximately 20 mm from the
connection between inductor and capacitor. To prevent damping of this circuit, the aerial coupling should be
kept as small as possible.
18.6.3 Capacitor
The capacitance value shall be such that the resonance frequency of the LC circuit is sufficiently close to the
specified measuring frequency. The quality factor should be as high as possible and be known as accurately
as possible to allow for correction. It is recommended that an air dielectric capacitor be used.
18.6.4.1 Oscilloscope
The sensitivity shall not be less than 0.1 mV/mm. The relative inaccuracy of voltage measurement shall not
exceed 1.5%.
18.6.4.2 Probe
The input impedance should be as high as is consistent with practical attenuation ratios. The following probe
is recommended: attenuation ratio 10:1; input impedance 10 MΩ, 7 pF.
61
IEEE
Std 389-1996 IEEE RECOMMENDED PRACTICE FOR TESTING
With the pulse generator switched off, the frequency of the oscillator is varied until maximum deflection is
obtained on the oscilloscope. The frequency is noted and shall be sufficiently close to the specified measur-
ing frequency. When this is not the case, the capacitance value shall be adjusted. The signal generator is then
switched off and the pulse generator is switched on. Its antenna is so adjusted that a reasonable deflection
appears on the oscilloscope. The sweep of the oscilloscope is adjusted to obtain a picture in accordance with
figure 52 (a) (for measurement of high-quality factors) or with figure 52 (b) (for measurement of lower-qual-
ity factors). The voltage values at two points of time are read from the oscilloscope, together with either the
time interval or the number of cycles between these two values.
Note—The Q-factor for excitation level sensitive inductors and transformers may depend on the position and magnitude
of t (or n) for which the voltages U1 and U2 are measured. The higher the Q-factor and the higher the excitation level
applied to the LC circuit, the stronger may be the dependence of the Q-factor on the position and magnitude of t (or n).
If accurate Q-factor measurements are required, then the position and magnitude of t (or n) should be specified, or the
voltage U1 and U2 should be measured during a later period of the dampened oscillations.
62
IEEE
ELECTRONICS TRANSFORMERS AND INDUCTORS Std 389-1996
18.6.6 Calculation
ωt
Q i = -------------------- (56)
U
2 log ------1
U2
πn
Q i = --------------- (57)
U
log ------1
U2
where
R0 ⋅ Qi
Q LC = -------------------------
- (58)
R 0 – Q i ωL
where
Q LC ⋅ Q C
Q L = ----------------------
- (59)
Q C – Q LC
where
The concept of the common-mode rejection test is illustrated in figure 53. The input terminals of the
transformer are connected to the high terminal of a voltage source through equal impedances R1. The low
terminal of the source is connected to ground reference. The voltage induced across the secondary
63
IEEE
Std 389-1996 IEEE RECOMMENDED PRACTICE FOR TESTING
winding (terminated with a specified impedance R2) is measured. The common-mode voltage transfer ratio
is r = e 2 ⁄ e 1 .
If the primary or secondary windings of the transformer, or both, have center taps, these shall be either
grounded or in a defined state of termination. The same applies to other windings of the transformer. The
driving impedances R1 can be omitted, and the terminating impedance R2 can be equal to the impedance of
the measuring instrument for e2, if so specified.
NOTE—The following information must be stated: transformer connections, including earth connections; test fre-
quency; input impedance (2R1); and load resistor R2.
20.1 Measurement
For small transformers, the inrush-current due to closure of the switch connecting the transformer primary to
the supply lines can be measured by oscillographic or storage oscilloscope records of primary no-load
exciting currents for a number of circuit closures. For single-phase transformers, 20 closures will probably
be sufficient to approximate the maximum inrush current. For three-phase transformers at least 60 closures
will be required to approximate the maximum value of inrush current. If a synchronous switch (with con-
trolled but variable closure time with respect to power supply) is available, then the worst case (highest
value) of inrush current can be obtained with many fewer closures if the closure time is adjusted to occur at
the time of zero voltage crossing for single-phase operation and the number of conducting half-cycles is
made an odd number. For three-phase operation, both the closure time and the conducting time of the other
phases should be varied until a worst-case condition is obtained. Information relative to or control of the
inrush current, or both, is of concern in determining the required fuse rating for overcurrent protection of all
transformers and for determining the mechanical bracing of the coils of large transformers for rectifier power
supplies. Since transformer manufacturers may not have ac power sources of sufficiently low impedance to
determine inrush-current characteristics by test, means have been devised to determine these characteristics
by calculation.
20.2 Calculation
Reference [B2] discusses the inrush-current phenomenon and suggests a method for calculating the peak
value of the first current peak. The equation uses the magnetic characteristics of the core material, the
operating flux density of the design, and certain dimensions of the core and of the primary coils, and
64
IEEE
ELECTRONICS TRANSFORMERS AND INDUCTORS Std 389-1996
assumes zero source impedance and zero winding resistance. Peak inrush current (in MKS units) can be
found as follows:
Vf – Va 2 ⋅ Bm ( N Ac ) – ( Bs – Br ) ( N Ac )
i pk = -------------------------------------------------------------
- = -------------------------------------------------------------------------
- (60)
air core inductance of coil µ0 N 2 As ⁄ b
where
The value to use for Br is a function of the design value Bm and of the type of core fabrication used in the
transformer. The following ratios are commonly accepted maximums for oriented silicon steel cores:
Equation (59) applies to a single-phase transformer and to the coil current of delta-connected primary wind-
ings of a three-phase transformer or three single-phase transformers. For a three-phase wye-delta-connected
bank of single-phase transformers and a three-legged core-type three-phase unit in wye connection, the
inrush currents are approximately two thirds of the value for a single-phase unit.
NOTE—For single-phase core-type units with a coil on each leg, if coils are series-connected, N is total turns and b is
2 ˙ b of each leg; if coils are paralleled, ipk is two times that for a single coil on one leg.
More extensive and detailed information regarding the inrush-current characteristics of transformers is pre-
sented in [B1]. That reference includes information regarding several factors affecting the magnitude of
inrush currents such as source impedance, system voltage level, switching angle, etc. It also includes the
characteristics that affect the duration of the inrush current, which is of importance with respect to the rat-
ings of protective fuses. It reports that as a result of an extensive study of the inrush currents of representa-
tive samples from a complete line of transformers, under conditions designed to produce the greatest inrush
current and the slowest rate of delay, it was found that for each transformer tested, and allowing a reasonable
margin in excess of the actual measured I2t, the fusing should be such as to allow 12 times the transformer
full-load primary current to flow for 0.1 s without fuse blowout. For a more sophisticated determination of
the I2t values, rms values, and average values of inrush current, consult [B9].
65
IEEE
Std 389-1996 IEEE RECOMMENDED PRACTICE FOR TESTING
21.1 General
The term current transformer is used to designate a transformer connected in series with a source or load.
Current transformers are used primarily as instrumentation devices for measuring or sensing current. A cur-
rent transformer is a coupled circuit and all the principles and tests described in the preceding clauses can be
applied. However, due to differences in construction, in voltage and current ratings, and in applications as
compared to conventional voltage transformers, there are certain terms, tests, and specifications that are
unique to current transformers.
It is often convenient to think of the current transformer as the inverse of the voltage transformer: the no-load
condition of a current transformer is with the secondary short-circuited on itself; an open-circuited
secondary can result in dangerous voltage levels; current transformers are almost invariably current step-
down transformers, i.e., the primary has a very low number of turns, often only one turn; and being a series-
connected device, a current transformer is designed for minimum voltage between primary terminals. There
are certain other differences between current and voltage transformers. Accuracy of the ratio of primary to
secondary current is usually the most important specification of a current transformer and is specified as both
a magnitude and a phase-angle error or accuracy. The load on the secondary of a current transformer is an
unwanted quantity (since it causes the ratio and phase-angle errors), and is referred to as the burden (see
clause 3). The primary of many instrument transformers is often not an integral part of the transformer itself,
but merely a lead of the circuit whose current is being measured. In electronics applications, current trans-
formers are frequently applied to systems with pulsed excitation. Therefore, the terminology and definitions
of clause 8, 11.2, and clause 16 of this recommended practice and those of IEEE Std 393-1991 should be
reviewed.
I
---1- = N ( 1 + a )e – jβ (61)
I2
where
I
---1- = N ( 1 + a – jβ ) (62)
I2
where
66
IEEE
ELECTRONICS TRANSFORMERS AND INDUCTORS Std 389-1996
A recommended test circuit is shown in figure 54. The primary of the current transformer is connected in
series with a noninductive resistor R1. The secondary is connected in series with a noninductive potentiome-
ter R2 and the primary winding of a suitable, variable, mutual inductor M. The resistors are connected in
series with a suitable detector and the secondary of the mutual inductor. Note that the polarity of the wind-
ings of the current transformer shall be as shown so that the voltages across R1 and R2 are in series opposi-
tion with respect to the detector. The polarity of the windings of M should also be as shown.
Balance is obtained by adjusting R2 and M for a null on the detector. At balance, the equations for the current
transformation ratio and the phase angle are, to a first approximation,
R
current transformation ratio = -----2-
R1
ωM
phase angle β = --------- + θ 1 – θ 2 [radian]
R2
where R1 and R2 are the values of the resistors (note that R2 is the portion of that resistor in the detector
loop), and θ1 and θ2 are the phase angles of I1 and I2, respectively.
22. Bibliography
[B1] Blume, L. F.; Canille, A.; Furnham, S. B.; and Peterson, H. A.; “Transformer Magnetizing Inrush Cur-
rents and Influences on System Operation,” Transactions of the AIEE, vol. 63, pp. 366–375, 1944.
[B4] Connelly, F. C., Transformers: Their Principles and Design for Light Electrical Engineers. London:
Pitman, 1950, pp. 204–213.
[B6] Grossner, N. R., Transformers for Electronics Circuit. New York: McGraw-Hill, 1967, p. 225.
[B7] Kreuger, F. H., Discharge Detection in High-Voltage Equipment. New York: American Elsevier, 1965.
67
IEEE
Std 389-1996 IEEE RECOMMENDED PRACTICE FOR TESTING
[B8] Munk, P. R., and Sartori, E. F., “A Theoretical and Experimental Study of Transformer Balances,” IEEE
Transactions on Parts, Materials, and Packaging, vol. PMP-4, Mar. 1968.
[B9] Specht, T. R., “Transformer Inrush Currents,” Transactions of the AIEE, vol. 70, pp. 323–328, 1951.
[B10] Terman, F. E., Radio Engineers’ Handbook, 1st ed. New York: McGraw-Hill, 1943.
68
IEEE
ELECTRONICS TRANSFORMERS AND INDUCTORS Std 389-1996
Annex A
(informative)
A.1 General
The unique nature of inductive devices having ferromagnetic cores requires a clarification of two terms asso-
ciated with measuring alternating currents and voltages, that is, the meaning of true rms and flux voltage
measurements.
The magnitude of alternating current or voltage is traditionally defined by its root-mean-square (rms) value.
The rms value is a measure of the energy content of the voltage or current. It is defined mathematically as
1 T
Vrms = ---
T ∫ ( v( t ) )2dt (A.1)
0
where
Unless otherwise identified (as average, peak, or peak-to-peak reading) ac voltmeters by tradition indicate
the rms value of a measured sinusoidal voltage. Because of variations in their operating principles, not all
ac instruments measure the true rms value when the measured quantity has frequency components other than
1/T. To measure true rms value, the instrument must indicate in proportion with the power absorbed by it
from the voltage or current source. Of the common analog indicating instruments, the following are true rms
indicating: the thermocouple type and the dynamometer type. In electronic voltmeters, including digital
instruments, true rms measurements are accomplished either by thermal conversion of a current to an equiv-
alent dc value or by analog evaluation or approximation of the root-mean-square or mean-square values of
the input waveform. True rms measuring instruments are normally identified as such by their manufacturers.
Because in electronic instruments the true rms detector is normally preceded by linear analog circuits, care
must be taken not to exceed the maximum peak input and rate of change they can handle without distortion.
The manufacturer’s rating for input frequency and maximum crest factor shall be observed.
The instantaneous voltage induced in a winding is a direct function of the rate of change of the magnetic flux
linking it (Faraday’s law). The average value of this voltage over a period of time is a direct function of the
net change of flux over the same period. Thus in the measurement of voltages induced across a winding, it is
often desirable to measure the average value rather than the true rms value. By convention a flux volt is
69
IEEE
Std 389-1996 IEEE RECOMMENDED PRACTICE FOR TESTING
defined as 1.111 times the average of the absolute value of an alternating, undistorted, sinusoidal voltage of
1 V rms. The average of the absolute value is defined mathematically as
1 T
Vavg = --- =
T ∫ v(t ) dt (A.2)
0
Therefore if an instrument detects the average value of the measured quantity but is calibrated so that it dis-
plays 1.111 times that, it will indicate the rms value of the undistorted sinusoidal function that would have
the same average of absolute value. These instruments are called “average responding, rms calibrated.” Most
low-cost electronic-type instruments fall into this category since they detect ac signals by simple rectifica-
tion and averaging (filtering). Of the analog meters the D’Arsonval type movement with rectified input is a
common instrument of this type.
A.4 Applications
The need to use “flux” voltmeters arises from the need to know accurately the magnitude of flux changes in
the magnetic cores. In an equation such as E = 4.44 NfABm , the equation relating induced voltage to
frequency, number of turns, and net flux change for periodic excitation, Bm, can be accurately computed if E
has frequency components other than f, even though the form factor is applicable to sine wave only. The true
rms values shall be measured wherever power, or the energy content of the measured quantity, is needed.
The values of winding currents shall always be measured true rms, also the winding voltages for loaded
tests. As an example, when the no-load exciting current of a transformer is to be measured, at a peak flux in
the core, the voltage applied to the winding should be measured by a flux voltmeter and the current by a true
rms instrument.
70
IEEE
ELECTRONICS TRANSFORMERS AND INDUCTORS Std 389-1996
Annex B
(informative)
B.1 General
AC high-potential dielectric testing (also known as hi-pot testing) is the application of an abnormally high
alternating voltage between two (or more) isolated elements of an electrical device to test the integrity of the
electrical insulation system. If there is no breakdown of the insulation system after applying a specified rms
voltage level for a specified time, then the insulation system is considered to have satisfactory integrity. In
order to define what is and what is not a breakdown (failure), the nature of leakage current, corona, and
breakdown, in that order, must be discussed.
The total leakage current IT at any specified rms voltage and frequency is a composite current made up of
insulation resistance current IR and capacitive current IC, which is in quadrature. This is related by the
equation
IT = ( I R )2 + ( I C )2
Almost always the largest component of leakage current by far is the capacitive current IC. The amount of IC
can vary considerably from one type of device to another. Some larger transformers with one winding sur-
rounded by other windings or electrostatic shields can easily have a few milliamperes of IC at 2500 V rms,
60 Hz (a commonly specified voltage and frequency). Some test equipment meters the leakage current IT
while others “sense” the current through a resistor using the resultant voltage drop on the resistor to “trip” a
relay causing a failure light or a horn to sound. This type of equipment can indicate a “failure” when, in fact,
there is no breakdown but a moderately high leakage current due to IC. Generally speaking, leakage current
IT is, within some reasonable limits, not a cause for rejection of a device. When ac high-potential testing is
done immediately after a “burn-out” test (operating a transformer at rated input with secondary windings
short-circuited for 6 h or until it burns out opening the primary), the insulation system will be very hot. At
these temperatures the dielectric constant usually increases substantially, which increases IC proportionately.
Also at these temperatures the insulation resistance usually drops a few orders of magnitude, causing IR to
increase proportionately. Again, this type of leakage current is acceptable and the device would pass the test
providing that there is no breakdown of the insulation system.
B.3 Corona
Corona is a discharge due to ionization of air in voids, microvoids, or space around terminations. Corona
itself is bad because it causes an accelerated aging of the insulation material leading to failure and break-
down. The aging effects of corona are accumulative. Corona inception occurs at certain voltage levels in all
insulation materials. While that voltage level is different for different materials and for different thicknesses
of the same material, it can generally be said that most insulation materials have corona inception at approx-
imately 100 V/mil (mil = 0.001 in) or approximately 3900 V/mm. When two or more different materials are
used in an insulation system between two electrodes, the voltage dividing effect of the different dielectric
constants must be considered when determining the volts per mil (or per millimeter) on each insulation. The
71
IEEE
Std 389-1996 IEEE RECOMMENDED PRACTICE FOR TESTING
material with the lowest dielectric constant will inherently have the highest volt per mil (or per millimeter)
stress. Care must be taken not to allow corona at normal or maximum operating voltage levels. However,
under high-potential testing some corona may be allowed and generally exists. If it occurs in high levels at
the high-potential voltage, it may cause an arc-through in the insulation and result in an insulation break-
down. If no breakdown occurs after 1 min of high-potential test, then it is acceptable.
B.4 Breakdown
Breakdown of the insulation system may take different forms. It may occur during the high-potential test, or
it may have occurred prior to the test due to damaged insulation material or an assembly error that caused
electrical connections to touch or come in close proximity with each other allowing the high voltage to arc
over on application. When breakdown occurs during the high-potential test, it can be detected by sporadic
and intermittent increases in leakage current IT at first, followed by a great increase to some constant high
level, which on many high-potential test sets is accompanied by a collapse of the voltage to some lower level
or completely. This type of breakdown may be caused by partial breakdown in ionized voids and weakened
insulation, which then avalanches to a complete breakdown in the form of an arc-over or an arc-through.
The range of types of transformers and other electrical devices that require high-potential testing up to
approximately 2500 V rms, 50 or 60 Hz, are such that the capacitive current IC will generally not be over
5 mA rms. A high-potential test set with approximately 15 mA rms current limiting at 2500 V should be
quite adequate. However, limiting the current to 5 mA rms or less may be restrictive in the test of electrical
devices with high interelectrode capacitance. Measurement of interelectrode capacitance will allow one to
determine the value of IC expected during any given high-potential test.
72
IEEE
ELECTRONICS TRANSFORMERS AND INDUCTORS Std 389-1996
Annex C
(informative)
73
IEEE
ELECTRONICS TRANSFORMERS AND INDUCTORS Std 389-1996
74