1. 100 SERIES SPECS & ELECTRICAL REQUIREMENTS
2. 1000 SERIES SPECS & ELECTRICAL REQUIREMENTS
3. INSTALLATION
4. KEYPAD FUNCTIONS
5. KEYPAD FUNCTIONS
6. KEYPAD FUNCTIONS
10. TROUBLESHOOTING
11. TROUBLESHOOTING
GEAR
BOX
MOTOR
DANCER ARM
Electrical requirements:
120vac
60hz
20 amp outlet
1
1000 SERIES STOCK REEL
COIL CONTROL
RETAINING
ARMS
TO ACCESS
GEAR BOX
& MOTOR
REMOVE
DANCER ARM THIS
PANEL
Electrical requirements:
Up to 1 hp 120vac, 60hz, 20 amp outlet
1-1/2 hp 230vac, 60hz, 12 amp
2 hp 230vac, 60hz, 15 amp
3 hp 230vac, 60hz, 25 amp
2
INSTALLATION
1. Your stock reel is fully assembled and ready to be put into
position. Visually inspect unit for damaged or loose parts
due to shipment. If there is physical damage, consult carrier.
3
KEYPAD FUNCTIONS
ON RESET
RAPID-AIR
OFF Mode
STOP/
Direction Function
CW PAYOUT
LOOP
Type Range
LOOP
Height
LOOP
Speed
%
ARM RANGE HT. SPEED
RUN/ JOG
JOG CCW REWIND
EXTER. + + +
LOOP LOOP %
RANGE HT. SPEED
- - -
Min-0 Min-0 Min-0
STOCK REEL Max- 8 Max- 8 Max- 8
Operating Instructions
On/Off switch
This illuminated switch is the main power switch for the
controller. It must be "ON" for the reel to function.
Reset switch
This is the main circuit breaker for the reel.
Run/Stop/Jog
In the Run mode, if the dancer arm is moved the coil will turn.
In the Jog mode, the jog button has to be depressed for the
coil to turn. Jog function is used mainly for setup or rewinding
excess material.
In the Stop mode there is no movement of the coil.
4
KEYPAD FUNCTIONS
Payout/Rewind function
The Payout/Rewind function selects how the dancer arm will
work as the dancer arm is raised or lowered.
In the Payout mode the reel speed will increase as the dancer
arm is raised. In the Rewind mode the reel speed will increase
as the dancer arm is lowered.
Note: this function can only be changed with reel in "Stop mode"
5
KEYPAD FUNCTIONS
Loop range/height
The loop range function selects the degree of arm movement
to achieve maximum motor speed. If a loop range of "0" was
selected the the arm would only have to travel approximately
6° to have the reel at full speed. If a loop range of "8" was
selected the arm would travel approximately 60° to have the
reel at full speed. This function is active in the "RUN" mode.
% Speed setting
The % speed setting allows you to adjust the maximum speed
the reel will rotate. This should be set to maintain a constant
feed rate. This function is active in the "RUN" mode.
6
JOG SPEED ADJUSTMENT & DANCER ARM
CALIBRATION
Your reel was shipped with the dancer arm set up for it's correct
position so the only thing that has to be reset would be the jog
speed if you need your unit to jog faster or slower.
To reset the jog speed, turn off the main power switch. Press and
hold the "Run/Stop/Jog" button while turning the main power switch
on. The first screen you will see will display the jog speed percentage.
The next screen asks if you want to set up the sensor (commonly
referred to as "dancer arm calibration"). Use the percent speed
buttons to select "yes" or "no".
Select "no" if all you wanted to do was change the jog speed, select
"yes" if you want to calibrate the dancer arm by resetting the sensor.
After making your selection, press
SETUP SENSOR YES
"Run/Stop/Jog" for next.
NEXT NO
If you selected "yes" the next screen asks you to set the low set point.
If the dancer arm is resting on the positive stop then just save this
setting by pushing the "Run/Stop/Jog" button.
7
JOG SPEED ADJUSTMENT & DANCER ARM
CALIBRATION
The next screen is for setting the high set point. Raise the dancer
arm to it's upper stop position and press the "Run/Stop/Jog" button
once to save this setting.
LOW OFFSET +0 +
_
NEXT
You now have set the dancer arm limits. The next screen to appear
allows you to exit the setup. Use the percent speed button to enter
"yes or no".
If "yes" was selected press "Run/Stop/Jog" button and the next screen
appears.
SHUT OFF POWER TO
SAVE AND EXIT
Power off unit, the dancer arm is now ready for production running.
8
MAINTENANCE
FILL/
BREATHER
FILL/
BREATHER
OIL
OIL LEVEL OIL OIL
SIGHT LEVEL PLUG
DRAIN
DRAIN
R20,R30,R40 R50
Fill to center of oil sight Fill to center of oil plug
Mobil 600w Mobil SHC630
Approx. 27 oz. Approx. 20 oz.
9
TROUBLESHOOTING
10
TROUBLESHOOTING
5. Percent speed function set too low
a. Adjust percent speed function to 100%
6. Fuses blown
a. Check fuses & circuit breaker
69100804 Board
29100021
Potentiometer
69100014
Board
11
LIGHTED
MAIN ROCKER SWITCH
BREAKER
CHASSIS
L1 BLK L11 3 1 1
15 AMP
69100578
115 VAC GRN R
69100315
69300001
2 WHT 2 2
69100804 P1 P3
IR CL I2
REEL CONTROL BOARD - M +
2 MIN MAX
WHT L2
REAR VIEW F3 1
MOTOR RED L1 I1 P2
F2 10
BLU A+
9
BLU A- RAMM 125 ACCEL.
FIELD - 69100014
2 LINE READOUT
SPEEDPOT HI P3
FOR OPERATOR TUNING BLU 8
SPEEDPOT LO P1
7
BLU SPEEDPOT WIPER P2
I1
A+ DECEL
I2
F- L2 L1
12
A- 9 9 BLU
9
P1 8 8 BLU
8
P2 7 7 BLU 1 2 3
7
6 POT #1 6 GRN
5 EXTERNAL LOOP CNTRL INPUT SIGNAL TEST POINT
4 POT #2 4 BRN
POT #3 3 BLU
3 2 WHT
AC IN 2 WHT
2 1 RED
AC IN 1 RED
1
F1 Troubleshooting notes:
Voltage to dancer arm between wire #3 & #6 should measure 5 VDC.
1.5 AMP Dancer arm movement should result in about a 1500 ohm swing.
PICO FUSE Dancer arm movement should result in about a 0.75 VDC swing.
WIRING DIAGRAM
MALE
PART NAME