Call Letters

PSTC 5

Date of Issuance 02/59
Revised 05/59
Revised 11/70
Revised 08/85
Revised 08/89
Quick Stick of Revised
Revised
06/00
10/03
Pressure Sensitive Tapes Revised 05/07

1. DEFINITION
1.1 Quick stick is the property of a pressure sensitive tape that allows it to adhere to a surface
under very slight pressure.

It is measured as the force resisting peeling of a unit width of tape at a 90˚ angle from a standard
surface upon which it has been applied under no other pressure than the weight of the tape itself.

2. SIGNIFICANCE
2.1 Quick stick is a measure of a tape’s ability to adhere with minimum pressure.

3. TEST SPECIMEN
3.1 For test specimen conditioning, selection, and test conditions, see Appendices A & D.

3.2 The test specimen shall be no greater than 24 mm (1”) nor less than 12 mm (1/2”) wide and
approximately 300 to 375 mm (12 to 15”) long. A width tolerance of ± 0.04 mm (1/64”) shall be
allowed.

4. EQUIPMENT - See Appendix B


4.1 Tensile tester.

4.2 Panel.

4.3 Fixture, quick stick test.

5. TEST METHOD
5.1 Clean panel as per method in Appendix C.

5.2 Hold the specimen parallel to and about 100 mm (4”) above the cleaned test panel so that
125 mm (5”) at one end is directly over the panel length. Touch the specimen end directly above
the panel to the end of the panel nearest to it. Relax tension at the other end of specimen allowing
specimen to drape smoothly onto panel. Assure that the tape is put on the panel without any foreign
pressure and that the edges of the tape run parallel to the long edges of the panel (Figure 1).

5.3 Immediately insert the panel (the end of the panel with the free end of the test specimen first)
into the fixture which has previously been secured in the lower jaw of the adhesion machine. Place
the hook of the pulling cord on the far end of the panel if test jig is equipped accordingly (Figure 2).
Fold over the adhesive surface of the free end to form a 24 mm (1”) tab and clamp in the upper jaw
of the adhesion tester. Make sure at this point that the free end is taut and the panel in the fixture
is in a position so that the free end forms a right angle with the panel. Start crosshead or moveable
jaw in motion immediately at a rate of 300 mm/min (12”/min). Disregard the values obtained while
the first 24 mm (1”) of tape is peeled mechanically. Use the average peel value obtained during the
removal of the next 24 to 48 mm (1” to 2”) as the quick stick value. Note: A trial run should be
made prior to testing so that the length of the tape is taut and forms a right angle with the panel as in
Figures 3 and 4. The test fixture is constructed so that the test panel will move at the same speed as
the tensile tester movable jaw when the foregoing is done, thus maintaining a 90˚ angle of peel.

5.4 Repeat sections 5.1 through 5.3 four more times for a total of five replicate tests.

A Summary of Changes section appears at the end of this test method.

5-1
6. REPORT
6.1 Report the quick stick value(s) to the nearest 0.01 Newtons per centimeter (or to the nearest
ounces per inch) of width.

SUMMARY OF CHANGES

• Added section 5.4 to define recommended number of replicate tests.

Figure 1. Quick stick specimen preparation.

5-2
Figure 2. Inserting panel and hook attachment.

Figure 3. Test jig with pull cord.

5-3
Figure 4. Test jig with bearings.

5-4