INSTRUCTION MANUAL
BilgMon488
15 ppm Bilge Alarm
BilgMon488 Instruction Manual vT 2/33
Table of Contents
1. Table of validity..........................................................................................................3
2. Introduction................................................................................................................4
3. Construction...............................................................................................................4
4. Operation....................................................................................................................5
5. Caution.......................................................................................................................5
6. Specification...............................................................................................................6
6.1. General................................................................................................................6
6.2. Specific 115/230 V AC model............................................................................7
6.3. Specific 24 V AC/DC model..............................................................................7
7. Installation..................................................................................................................8
8. Calibration................................................................................................................14
8.1. Calibration certificate expiration......................................................................14
8.2. Calibration check requirements........................................................................14
9. Operating Instructions..............................................................................................15
10. Simulation..............................................................................................................26
11. Contrast..................................................................................................................26
12. Automatic stopping device test..............................................................................27
12.1. While separator is active.................................................................................27
12.2. While separator is not active...........................................................................27
13. Response test..........................................................................................................27
13.1. Step 1..............................................................................................................27
13.2. Step 2..............................................................................................................27
13.3. Alternative......................................................................................................27
14. Calibration check (40 NTU)...................................................................................28
15. Log entries..............................................................................................................29
16. Maintenance...........................................................................................................30
17. Spare parts list........................................................................................................31
18. Troubleshooting......................................................................................................33
Brännströms Elektronik AB
Uddevallagatan 14
416 70 Göteborg
Tfn: +46 31 19 56 00
Fax: +46 31 19 77 90
info@brannstrom.se ♦ www.brannstrom.se
BilgMon488 Instruction Manual vT 3/33
1. Table of validity
The following table describes the software and hardware versions on which this
document was based.
Doc version MASTER MASTER SENSOR SENSOR
SW ver. PCB ver. SW ver. PCB ver.
vN A3 Bilgbas_H.1/ F Bilgemon H.1
Bilgbaslv_C.1
Bilgemaster L.1
vO, vP A4 Bilgbas_H.1/ B2 Bilgemon J.1
Bilgbaslv_D.1
Bilgemaster L.1
vQ,vR A4 Bilgbase_H.1/ B2 Bilgemon J.1
Bilgbaslv_D.1/
Bilgbasco_A
Bilgemaster L.1
vS,vT A9 Bilgbase_I.1/ B5 Bilgemon J.1
Bilgbaslv_D.1/
Bilgbasco_A
Bilgemaster N.1
Brännströms Elektronik AB
Uddevallagatan 14
416 70 Göteborg
Tfn: +46 31 19 56 00
Fax: +46 31 19 77 90
info@brannstrom.se ♦ www.brannstrom.se
BilgMon488 Instruction Manual vT 4/33
2. Introduction
The BilgMon488 bilge alarm has been designed specifically for use in conjunction
with 15 ppm oil-water separator units. BilgMon488 performance meets the
requirements of the International Maritime Organisation specifications for 15 ppm
bilge alarms contained in resolution MEPC. 107(49).
BilgMon488 is equipped with 2 adjustable alarms that are triggered when the oil-
content of the processed sample exceeds the set limit (1 – 15 ppm, works-adjusted to
15ppm). Alarm outputs consist of relays and indicator LEDs. Additionally a 0(4) – 20
mA current output signal (corresponding to 0 – 30 ppm) is available to enable remote
surveillance and recording of oil contents.
3. Construction
BilgMon488 consists of two main parts, the MASTER unit (housing with LCD,
buttons and LEDs) and the SENSOR unit (housing with pipe fittings).
The MASTER unit contains all the electronics used for control and data storage of the
bilge alarm. Mounted in the lid of the MASTER housing is the main memory
containing the bilge alarm log.
The SENSOR unit contains electronics for measuring the sample stream. The
SENSOR unit also holds the measurement calibration data. Communication with the
MASTER unit is done wireless hence the SENSOR unit is hermetically sealed and
shall not be opened.
Brännströms Elektronik AB
Uddevallagatan 14
416 70 Göteborg
Tfn: +46 31 19 56 00
Fax: +46 31 19 77 90
info@brannstrom.se ♦ www.brannstrom.se
BilgMon488 Instruction Manual vT 5/33
4. Operation
Optical sensors monitors the amount of light scattered and absorbed by the oil droplets
in the sample stream. Sensor signals are processed by a microprocessor to produce a
corresponding oil content (ppm) output. The output is communicated to the MASTER
unit where it is processed. The MASTER unit takes action, such as alarm activation,
logging etc., depending on the oil content and the separator signal.
Settings that affect the behaviour of the bilge alarm are described in detail in the
”Operating Instructions” section.
Zero point calibration can be re-adjusted on site whereas full sensor calibration
according to IMO-requirements is performed by manufacturer.
5. Caution
The lid of the MASTER unit contains a small battery (watch battery). This battery
enables the BilgMon488 to keep track of time and date (real time clock, RTC).
Do NOT under any circumstance remove this battery as it will cause a unrecoverable
error (“RTC check FAILED!!”).
Do NOT open the SENSOR unit as this will invalidate the calibration.
Do NOT open the MASTER unit when it is energized. Hazardous voltages are present
inside.
Brännströms Elektronik AB
Uddevallagatan 14
416 70 Göteborg
Tfn: +46 31 19 56 00
Fax: +46 31 19 77 90
info@brannstrom.se ♦ www.brannstrom.se
BilgMon488 Instruction Manual vT 6/33
6. Specification
6.1. General
Measurement:
Oil range: 0 – 30 ppm
Resolution: 0.1 ppm
Accuracy: According to IMO MEPC.107(49)
Response time: < 3 sec
Alarms:
Alarm 1 (valve control) delay: 0-10 sec user adjustable
Alarm 2 (annunciation) delay: 0-600 sec user adjustable
Alarm points 1 and 2: 1-15 ppm user adjustable
Alarm hysteresis: 0.5 ppm (below alarm point)
User interface:
LCD display: 2x16 alphanumeric display
Control: 4 button keypad
Brännströms Elektronik AB
Uddevallagatan 14
416 70 Göteborg
Tfn: +46 31 19 56 00
Fax: +46 31 19 77 90
info@brannstrom.se ♦ www.brannstrom.se
BilgMon488 Instruction Manual vT 7/33
Brännströms Elektronik AB
Uddevallagatan 14
416 70 Göteborg
Tfn: +46 31 19 56 00
Fax: +46 31 19 77 90
info@brannstrom.se ♦ www.brannstrom.se
BilgMon488 Instruction Manual vT 8/33
7. Installation
Mechanical
Brännströms Elektronik AB
Uddevallagatan 14
416 70 Göteborg
Tfn: +46 31 19 56 00
Fax: +46 31 19 77 90
info@brannstrom.se ♦ www.brannstrom.se
BilgMon488 Instruction Manual vT 9/33
Brännströms Elektronik AB
Uddevallagatan 14
416 70 Göteborg
Tfn: +46 31 19 56 00
Fax: +46 31 19 77 90
info@brannstrom.se ♦ www.brannstrom.se
BilgMon488 Instruction Manual vT 10/33
NOTE (115/230 VAC model): There are two coils delivered with the BilgMon 488
one to be used with 110 VAC (marked 96 V) and one to be used with 220 VAC
(marked 205 V). Be shure to install the proper one for the choosen voltage.
NOTE (24 VAC/DC model): Only one coil delivered with this model (marked 24 V).
Brännströms Elektronik AB
Uddevallagatan 14
416 70 Göteborg
Tfn: +46 31 19 56 00
Fax: +46 31 19 77 90
info@brannstrom.se ♦ www.brannstrom.se
BilgMon488 Instruction Manual vT 11/33
Brännströms Elektronik AB
Uddevallagatan 14
416 70 Göteborg
Tfn: +46 31 19 56 00
Fax: +46 31 19 77 90
info@brannstrom.se ♦ www.brannstrom.se
BilgMon488 Instruction Manual vT 12/33
Brännströms Elektronik AB
Uddevallagatan 14
416 70 Göteborg
Tfn: +46 31 19 56 00
Fax: +46 31 19 77 90
info@brannstrom.se ♦ www.brannstrom.se
BilgMon488 Instruction Manual vT 13/33
Electrical connections
115VAC/230VAC
24V AC/DC
Brännströms Elektronik AB
Uddevallagatan 14
416 70 Göteborg
Tfn: +46 31 19 56 00
Fax: +46 31 19 77 90
info@brannstrom.se ♦ www.brannstrom.se
BilgMon488 Instruction Manual vT 14/33
8. Calibration
Two items needs to be addressed when setting up the maintenance schedule for the
BilgMon488:
• The calibration certificate expiration of the SENSOR unit.
• On occasions “calibration check” is required on a more regular basis.
The following two subchapters explain how to resolve these two items.
Brännströms Elektronik AB
Uddevallagatan 14
416 70 Göteborg
Tfn: +46 31 19 56 00
Fax: +46 31 19 77 90
info@brannstrom.se ♦ www.brannstrom.se
BilgMon488 Instruction Manual vT 15/33
9. Operating Instructions
The menu system of BilgMon488 is organised into 4 top menus:
1. Main menu.
2. Info menu.
3. Log menu.
4. Cleaning/test menu.
5. Settings menu.
Some of the menus also contain submenus for displaying or setting the properties of
the apparatus.
Navigating the menus is done by using the 4 push buttons located beneath the LCD
display. In this document they are referred to as (from left to right) MINUS, PLUS,
ABORT and ENTER. LONG_ENTER means keeping the ENTER button pressed for
more than 2 seconds. By using the above mentioned buttons the user is able to
navigate menus, enter values and activate different functions of the BilgMon488 .
Brännströms Elektronik AB
Uddevallagatan 14
416 70 Göteborg
Tfn: +46 31 19 56 00
Fax: +46 31 19 77 90
info@brannstrom.se ♦ www.brannstrom.se
BilgMon488 Instruction Manual vT 16/33
• Main menu
After start the display will show the main menu. The apparatus can only be activated
when the display shows the main menu hence the user has to be sure that the
apparatus is left in the main menu state after performing settings, cleaning, tests etc.
Contrast of the LCD screen can be adjusted by holding the ABORT button while
adjusting with PLUS and MINUS when in main menu. Note that the apparatus will
return to the main menu after 5 min of no activity (no pressed buttons). The bilge
alarm can only be activated when in main menu. In all other menus the overboard
valve will be closed.
• Info menu
The submenus of info menu show information about the master unit (software version
and part ID) and the sensor unit (part ID, SW version, sensor birth date and date of
last calibration check). Note that entering the submenus also puts the apparatus in an
alarm state.
• Log menu
The log menu contains functionality for searching and stepping the logged IMO
required data.
• Settings menu
Settings menu contains adjustable settings of parameters such as ppm-limits,
alarm/valve time delays, autoflush settings, clock and current output (curro) mode.
Brännströms Elektronik AB
Uddevallagatan 14
416 70 Göteborg
Tfn: +46 31 19 56 00
Fax: +46 31 19 77 90
info@brannstrom.se ♦ www.brannstrom.se
BilgMon488 Instruction Manual vT 17/33
Clock
Curro max
Brännströms Elektronik AB
Uddevallagatan 14
416 70 Göteborg
Tfn: +46 31 19 56 00
Fax: +46 31 19 77 90
info@brannstrom.se ♦ www.brannstrom.se
BilgMon488 Instruction Manual vT 18/33
The following table shows the different menus and submenus of the BilgMon488 and
detailed instructions on how to operate them.
050327 10:06:00
PPM=07.2 SPL
The ”main menu” is
displayed at startup. The
values shown in this menu
are date, time, the
measured oil-content of the
sample in parts per million
(ppm) and the position of
the clean water valve (SPL
= sample, WTR = clean
water).
Press PLUS to go to next
menu.
Return to this menu by
pressing ABORT several
times.
If the second row shows
“Lost sensor com!” se
section Troubleshooting.
If the alarm is on (when
unit is active) the user can
acknowledge it by pressing
one of the buttons.
Acknowledging will turn
off the alarm output but
the alarm led will remain
lit until the PPM-value is
below the set alarm limit.
Brännströms Elektronik AB
Uddevallagatan 14
416 70 Göteborg
Tfn: +46 31 19 56 00
Fax: +46 31 19 77 90
info@brannstrom.se ♦ www.brannstrom.se
BilgMon488 Instruction Manual vT 19/33
The ”info menu” and its Continuous cycles with Master info
submenus contain information about the
information about the master unit (se right
system such as software column). Master ID:
versions, ID-numbers etc. Press MINUS to go to AC02-2321
To enter the info previous submenu.
submenus press ENTER. Press PLUS to go to next Master SW ver:
Press PLUS to go to next submenu. 000A
menu. Press ABORT to exit the
Return to this menu by submenu.
pressing ABORT several
times.
Sensor info
Sensor date:
050219 15:20:00
Cal. checked:
050220 10:00:00
T:25.3 Dry:60
V3:3.20 V03:.312
Brännströms Elektronik AB
Uddevallagatan 14
416 70 Göteborg
Tfn: +46 31 19 56 00
Fax: +46 31 19 77 90
info@brannstrom.se ♦ www.brannstrom.se
BilgMon488 Instruction Manual vT 20/33
Brännströms Elektronik AB
Uddevallagatan 14
416 70 Göteborg
Tfn: +46 31 19 56 00
Fax: +46 31 19 77 90
info@brannstrom.se ♦ www.brannstrom.se
BilgMon488 Instruction Manual vT 21/33
Brännströms Elektronik AB
Uddevallagatan 14
416 70 Göteborg
Tfn: +46 31 19 56 00
Fax: +46 31 19 77 90
info@brannstrom.se ♦ www.brannstrom.se
BilgMon488 Instruction Manual vT 22/33
Brännströms Elektronik AB
Uddevallagatan 14
416 70 Göteborg
Tfn: +46 31 19 56 00
Fax: +46 31 19 77 90
info@brannstrom.se ♦ www.brannstrom.se
BilgMon488 Instruction Manual vT 23/33
Brännströms Elektronik AB
Uddevallagatan 14
416 70 Göteborg
Tfn: +46 31 19 56 00
Fax: +46 31 19 77 90
info@brannstrom.se ♦ www.brannstrom.se
BilgMon488 Instruction Manual vT 24/33
Brännströms Elektronik AB
Uddevallagatan 14
416 70 Göteborg
Tfn: +46 31 19 56 00
Fax: +46 31 19 77 90
info@brannstrom.se ♦ www.brannstrom.se
BilgMon488 Instruction Manual vT 25/33
Brännströms Elektronik AB
Uddevallagatan 14
416 70 Göteborg
Tfn: +46 31 19 56 00
Fax: +46 31 19 77 90
info@brannstrom.se ♦ www.brannstrom.se
BilgMon488 Instruction Manual vT 26/33
10. Simulation
By holding the ENTER button pressed while in main menu lets the user simulate
different ppm values and separator input states. In this mode the The following table
shows the display in the simulation mode.
Simulation SPL
PPM=07.0 SEP_ON
PPM=03.0 ACT
Pressing the MINUS
button decreases the PPM
value by 1.0. Pressing the
PLUS button increases the
PPM value by 1.0. Pressing
the ABORT button toggles
the simulated separator
input (SEP_OFF =
separator off, SEP_ON =
separator on). In the upper
right corner of the display
an indication is given of
the clean water valve
position.
11. Contrast
By holding the ABORT button pressed while in main menu lets the user set the
contrast of the LCD screen. The following table shows the display when as seen when
adjusting the contrast.
Contrast: 010%
Brännströms Elektronik AB
Uddevallagatan 14
416 70 Göteborg
Tfn: +46 31 19 56 00
Fax: +46 31 19 77 90
info@brannstrom.se ♦ www.brannstrom.se
BilgMon488 Instruction Manual vT 27/33
13.2. Step 2
Testing alarms and valves are done in simulation mode (see “10. Simulation”) or in
the “Test outputs” submenu of the cleaning & test menu (see page 22) since this
doesn't require opening the MASTER housing.
13.3. Alternative
To make step 1 of the response test affect alarms and valves the apparatus needs to be
active. Bilgmon 488 is activated (flashing green led) when in main menu and the
separator input signal is active. Activation can be done by strapping connections 10
and 11 (see “Electrical connections”). This method is not recommended since there
is an obvious risk of forgetting the strap and that it requires opening the MASTER
unit.
Brännströms Elektronik AB
Uddevallagatan 14
416 70 Göteborg
Tfn: +46 31 19 56 00
Fax: +46 31 19 77 90
info@brannstrom.se ♦ www.brannstrom.se
BilgMon488 Instruction Manual vT 28/33
Brännströms Elektronik AB
Uddevallagatan 14
416 70 Göteborg
Tfn: +46 31 19 56 00
Fax: +46 31 19 77 90
info@brannstrom.se ♦ www.brannstrom.se
BilgMon488 Instruction Manual vT 29/33
Brännströms Elektronik AB
Uddevallagatan 14
416 70 Göteborg
Tfn: +46 31 19 56 00
Fax: +46 31 19 77 90
info@brannstrom.se ♦ www.brannstrom.se
BilgMon488 Instruction Manual vT 30/33
16. Maintenance
The BilgMon488 can be set to autoflush (see page 24). This means that the sensor
tube is flushed with clean water at durations and intervals as set in the settings menu.
Autoflush is only active when in main menu and BilgeMon488 is not active.
Cleaning the measurement unit should be done using a soft bottle-brush and mild
detergent. Note that there is a glass tube inside the SENSOR unit so don't use anything
that might scratch or damage the glass (i.e. metal objects). If the glass tube is layered
with rust or similar try using low concentrated acid (for example hydrochloric acid).
Rinse well and make sure you protect your eyes, skin and airways if using acidic
substances.
Brännströms Elektronik AB
Uddevallagatan 14
416 70 Göteborg
Tfn: +46 31 19 56 00
Fax: +46 31 19 77 90
info@brannstrom.se ♦ www.brannstrom.se
BilgMon488 Instruction Manual vT 31/33
Brännströms Elektronik AB
Uddevallagatan 14
416 70 Göteborg
Tfn: +46 31 19 56 00
Fax: +46 31 19 77 90
info@brannstrom.se ♦ www.brannstrom.se
BilgMon488 Instruction Manual vT 32/33
BilgMon488 Instruction Manual vT 33/33
18. Troubleshooting
Symptom Possible reason Servicing
BilgMon488 is switched on Power supply is erroneous. Check connections
but LCD remains blank. internally, externally and
power supply voltages.
or
or