Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Variable Frequency Drives A700

Download as pdf or txt
Download as pdf or txt
You are on page 1of 62

Variable Frequency Drives

Variable Frequency Drives

A700

A700 1/4 - 800 Hp


FUNCTION / PERFORMANCE

F700

F700 1 - 1000 Hp

E700 1/8 - 20 Hp

E E

E500
E560 1 - 10 Hp

D700 1/8 - 10 Hp

CAPACITY

Variable Frequency Drives Family......................................................................................................398


D700 Series.......................................................................................................................................399
E700 Series........................................................................................................................................405
E560 Series........................................................................................................................................411
F700 Series........................................................................................................................................414
A700 Series.......................................................................................................................................424
A701 Series.......................................................................................................................................435
V500 Series.......................................................................................................................................439
Engineered Solutions.........................................................................................................................443
General Options.................................................................................................................................452

Stock Product: Stock product is product MEAU makes every effort to have on hand for immediate shipment. There may be instances
when we are out of stock due to unexpected large requirements. All stock product will be indicated in this book by an “S” in the
Stocked Item columns/rows.

Non-Stock Product: Non-stock product is product supplied on an “as-needed” basis. Standard lead times of 12 - 16 weeks apply,
product is non-returnable and non-cancelable. Product listed as non-stock may change to stock product subject to increases in sales
and usage. All non-stock product will be indicated in this book by a dash “-” in the Stocked Item columns/rows.

Mitsubishi Electric Automation | Variable Frequency Drives 397


n VARIABLE FREQUENCY DRIVES

Variable Frequency Drives Family


Standard Features:
• RS-485 serial communications • Soft PWM
(Mitsubishi VFD protocol) • Engineered solutions available
• PID control Setup Software available
• Adjustable carrier frequency (Low Noise) • User selectable Sink (default) / Source I/O
up to 14.5kHz

Model Series D700 E560 E700 F700 A700


Voltage Range (VAC) 115 1Ø 240 1Ø 240 480 600 115 1Ø 240 1Ø 240 480 240 480 240 480 600
Constant Torque 1/2~125 1/2~800 1~650
Range

1/8~1 1/8~3 1/8~10 1/2~10 1~10 1/8~1 1/8~3 1/8~20 1/2~20 1~200 1~1000
HP

Variable Torque 1~200 1~1000 2~850


Open-Loop Flux
Yes Yes Yes No Yes
Vector Speed
Control Algorithm

Open-Loop Torque No No No No Yes


Closed-Loop Speed No No No No Yes
Closed-Loop Torque No No No No Yes
Closed-Loop Position No No No No Yes
Digital Inputs 5 (2 additional for Safety) 7 7 (expandable) 12 (expandable) 12 (expandable)
0~5 / 10VDC Yes Yes Yes No No
0~±5 / ±10VDC No No No Yes Yes
Inputs

4~20mA No Yes No No No
4~20mA or 0~5/10VDC Yes No Yes Yes (2 ports) Yes (2 ports)
Pulse (Speed) No No No No Yes
Digital Outputs 1 2 2 (expandable) 5 (expandable) 5 (expandable)
Relay Outputs 1 1 1 (expandable) 2 (expandable) 2 (expandable)
Outputs

0~10VDC Yes Yes Yes Yes Yes (expandable)


0~20mA No No No Yes (optional)
Pulse No No No No Yes
Modbus RTU Standard No Standard Standard Standard
CC-Link No Option Option Option Option
DeviceNet No Option Option Option Option
Profibus-DP No Option Option Option Option
LonWorks No Option Option Option Option
Communications

SSCNETIII No No No No Option
ControlNET No No No No Option
Metasys N2 Option Option Option Option Option
Siemens FLN Option Option Option Option Option
BACnet/MS/TP Standard Option Option Option Option
EtherNet/IP Option Option Option Option Option (2 types)
Modbus TCP/IP Option Option Option Option Option
BACnet/IP No No Option Option Option
Brake Transistor Yes (1/2HP and above) Yes Yes (1/2HP and above) No Up to 30HP
Up to
Brake Resistor Option Option Option No Up to 10HP
5HP
EMC Filter Option No Option Standard Standard No
DC Reactor Option No Option Option (standard 100HP and above)
Safety Stop Function Standard No Option No No
1
Communications Ports 1 (RS-485) 2 (RS-485 & USB) 2 (RS-485) 3 (2x RS-485 & USB)
(RS485)
Plug-in Option Ports 0 1 1 1 3
Operator Interface Standard Option Standard Standard Standard
FR-PU07
Alpha/Numeric Keypad Option FR-PU07 FR-PU04 FR-PU07 FR-PU07
FR-PU07-01
Alarm History Last 8 Last 8 Last 8 Last 8 Last 8

398
D700 Series
Low cost micro VFD with Mitsubishi Electric quality.

• Simple to use: The D700 is perfect for a wide range • 150% torque at 1Hz and 200% torque at 3Hz using
of applications General-purpose Magnetic Flux Vector Control
• Simple to set up: The integrated digital setting dial • Optimum Excitation Control for increased energy
with display makes configuration fast and easy savings when motor is not loaded
• Simple operation: Control remotely or with the • Frequency search function for catching a
built-in digital control spinning load
• Simple to choose: Low cost and with Mitsubishi • Dancer control allows position signal to control
Electric quality ensuring long operation life roll tension
• Capacity from 1/8 to 10 HP • Password function for parameter setting protection
• Safety stop function meets EN954-1 Category 3 and • Internal diagnostics function for monitoring status
IEC60204-1 Stop Category 0 of critical components
• Integrated brake chopper circuit • RoHS compliant
• Modbus RTU included as standard via the RJ45 port • 10 year maintenance free design

Voltage

115
1 Phase 1/8 – 1 Hp
FR-D720 – 008 – NA
240
1 Phase 1/8 – 3 Hp

240
1/8 – 10 Hp
Symbol Voltage Class 3 Phase
Inverter capacity
D710W 1-phase 115V class 480
amperage / 10 1/2 – 10 Hp
D720S 1-phase 240V class 3 Phase
(008 = 0.8A
D720 3-phase 240V class
output)
D740 3-phase 480V class Horsepower

D700 Series
Rating (CT & VT) IP20 Open Chassis Dimensions in inches (mm)
Weight Lbs (kg) Stocked Item
HP Rated Amps Model Number Height Width Depth
1-Phase 100~120VAC Input / 3-Phase 200~240VAC Output
1/8 0.8 FR-D710W-008-NA 5.0 (128) 2.7 (68) 3.2 (80.5) 1.1 (0.5) S
1/4 1.4 FR-D710W-014-NA 5.0 (128) 2.7 (68) 4.4 (110.5) 1.3 (0.6) S
1/2 2.5 FR-D710W-025-NA 5.0 (128) 2.7 (68) 5.6 (142.5) 2.0 (0.9) S
1 4.2 FR-D710W-042-NA 5.0 (128) 4.3 (108) 5.9 (149.5) 3.1 (1.4) S
1-Phase 200~240VAC Input / 3-Phase 200~240VAC Output
1/8 0.8 FR-D720S-008-NA 5.0 (128) 2.7 (68) 3.2 (80.5) 1.1 (0.5) S
1/4 1.4 FR-D720S-014-NA 5.0 (128) 2.7 (68) 3.2 (80.5) 1.3 (0.6) S
1/2 2.5 FR-D720S-025-NA 5.0 (128) 2.7 (68) 5.6 (142.5) 2.0 (0.9) S
1 4.2 FR-D720S-042-NA 5.0 (128) 2.7 (68) 6.5 (162.5) 2.5 (1.1) S
2 7 FR-D720S-070-NA 5.0 (128) 4.3 (108) 6.2 (155.5) 3.3 (1.5) S
3 10 FR-D720S-100-NA 5.9 (150) 5.5 (140) 5.7 (145) 4.4 (2.0) S
3-Phase 200~240VAC Input & Output
1/8 0.8 FR-D720-008-NA 5.0 (128) 2.7 (68) 3.2 (80.5) 1.1 (0.5) S
1/4 1.4 FR-D720-014-NA 5.0 (128) 2.7 (68) 3.2 (80.5) 1.1 (0.5) S
1/2 2.5 FR-D720-025-NA 5.0 (128) 2.7 (68) 4.5 (112.5) 1.8 (0.8) S
1 4.2 FR-D720-042-NA 5.0 (128) 2.7 (68) 5.3 (132.5) 2.2 (1.0) S
2 7 FR-D720-070-NA 5.0 (128) 4.3 (108) 5.4 (135.5) 3.1 (1.4) S
3 10 FR-D720-100-NA 5.0 (128) 4.3 (108) 5.4 (135.5) 3.1 (1.4) S
5 16.5 FR-D720-165-NA 5.0 (128) 6.7 (170) 5.6 (142.5) 4.0 (1.8) S
7 1/2 23.8 FR-D720-238-NA 5.9 (150) 8.7 (220) 6.1 (155) 8.0 (3.6) S
10 31.8 FR-D720-318-NA 5.9 (150) 8.7 (220) 6.1 (155) 8.0 (3.6) S
3-Phase 380~480VAC Input & Output
1/2 1.2 FR-D740-012-NA 5.0 (128) 4.3 (108) 5.1 (129.5) 2.9 (1.3) S
1 2.2 FR-D740-022-NA 5.0 (128) 4.3 (108) 5.1 (129.5) 2.9 (1.3) S
2 3.6 FR-D740-036-NA 5.0 (128) 4.3 (108) 5.4 (135.5) 3.1 (1.4) S
3 5 FR-D740-050-NA 5.0 (128) 4.3 (108) 6.2 (155.5) 3.3 (1.5) S
5 8 FR-D740-080-NA 5.0 (128) 4.3 (108) 6.6 (165.5) 3.3 (1.5) S
7 1/2 12 FR-D740-120-NA 5.9 (150) 8.7 (220) 6.1 (155) 7.3 (3.3) S
10 16 FR-D740-160-NA 5.9 (150) 8.7 (220) 6.1 (155) 7.3 (3.3) S

Mitsubishi Electric Automation | Variable Frequency Drives 399


n VARIABLE FREQUENCY DRIVES
D700 General Specifications
Soft-PWM control/high carrier frequency PWM control (V/F control, General-purpose magnetic flux vector control, Optimum excitation
Control Method
control can be selected)
Output Frequency Range 0.2 to 400Hz
Frequency Setting Analog Input 0.06Hz/60Hz (terminal2, 4: 0 to 10V/10bit) 0.12Hz/60Hz (terminal2, 4: 0 to 5V/9bit) 0.06Hz/60Hz (terminal4: 0 to 20mA/10bit)
Resolution Digital Input 0.01Hz
Analog Input Within ±1% of the max. output frequency (25°C ±10°C)
Control Specifications

Frequency
Accuracy Digital Input Within 0.01% of the set output frequency
Voltage/Frequency Characteristics Base frequency can be set from 0 to 400Hz. Constant torque/variable torque pattern can be selected
Starting Torque 150% or more (at 1Hz) when General-purpose magnetic flux vector control and slip compensation is set
Torque Boost Manual torque boost
Accel. /Decel. Time Setting 0.01 to 3600s (acceleration and deceleration can be set individually), linear or S-pattern acceleration/deceleration mode can be selected.
FR-D720-008 and 014, FR-D720S-008 and 014, FR-D710W-008 and 014 ... 150%, FR-D720-025 and 042, FR-D740-012 and 022,
Regeneration
FR-D720S-025 and 042, FR-D710W-025 and 042 ... 100%, FR-D720-070, FR-D740-036, FR-D720S-070 ... 50%, FR-D720-100 or
(*1)
Braking Torque more, FR-D740-050 or more, FR-D720S-100 ... 20%
DC Injection
Operation frequency (0 to 120Hz), operation time (0 to 10s), operation voltage (0 to 30%) variable
Brake
Stall Prevention Operation Level Operation current level can be set (0 to 200% adjustable), whether to use the function or not can be selected
Two points
Frequency Setting Analog Input Terminal 2: 0 to 10V, 0 to 5V can be selected
Signal Terminal 4: 0 to 10V, 0 to 5V, 4 to 20mA can be selected
Digital Input Entered from operation panel and parameter unit. Frequency setting increments is selectable.
Start Signal Forward and reverse rotation or start signal automatic self-holding input (3-wire input) can be selected.
Five points. You can select from among multi-speed selection, remote setting, second function selection, terminal 4 input selection,
JOG operation selection, PID control valid terminal, external thermal input, PU-external operation switchover, V/F switchover, output
Input Signal
stop, start self-holding selection, forward rotation, reverse rotation command, inverter reset, PU-NET operation switchover, external-
NET operation switchover, command source switchover, inverter operation enable signal, and PU operation external interlock
Maximum/minimum frequency setting, frequency jump operation, external thermal relay input selection, automatic restart after
Operation Specifications

instantaneous power failure operation, forward/reverse rotation prevention, remote setting, second function, multi-speed operation,
Operational Functions
regeneration avoidance, slip compensation, operation mode selection, offline auto tuning function, PID control, computer link
operation (RS-485), Optimum excitation control, power failure stop, speed smoothing control, Modbus-RTU
Open Collector
Output Signal One point
Output
Points
Relay Output One point
You can select from among inverter operation, up-to-frequency, overload alarm, output frequency detection, regenerative brake
prealarm, electronic thermal relay function prealarm, inverter operation ready, output current detection, zero current detection, PID
Output Signal

Operating Status lower limit, PID upper limit, PID forward/reverse rotation output, fan alarm (*3), heatsink overheat pre-alarm, deceleration at an
instantaneous power failure, PID control activated, PID output interruption, during retry, life alarm, current average value monitor,
remote output, alarm output, fault output, fault output 3, and maintenance timer alarm
For Meter
Analog Output 0 to 10VDC: one point
Output Points
You can select from among output frequency, output current (steady), output voltage, frequency setting, converter output voltage,
regenerative brake duty, electronic thermal relay function load factor, output current peak value, converter output voltage peak value,
For Meter
reference voltage output, motor load factor, PID set point, PID measured value, output power, PID deviation, motor thermal load
factor, inverter thermal load factor 0 to 10VDC
You can select from among output frequency, output current (steady), output voltage, frequency setting, cumulative energization time,
actual operation time, converter output voltage, regenerative brake duty, electronic thermal relay function load factor, output current
Operation Panel Operating Status
peak value, converter output voltage peak value, motor load factor, PID set point, PID measured value, PID deviation, inverter I/O
Parameter Unit terminal monitor, output power, cumulative power, motor thermal load factor, inverter thermal load factor, PTC thermistor resistance.
(FR-PU07)
Indication

Fault definition is displayed when the fault occurs and the past 8 fault definitions (output voltage/current/frequency/cumulative
Fault Definition
energization time right before the fault occurs) are stored
Additional Display Operating Status Not used
By The Parameter Fault Definition Output voltage/current/frequency/cumulative energization time immediately before the fault occurs
Unit (FR-PU04/ Interactive
FR-PU07) Only Function (help) for operation guide
Guidance
Overcurrent during acceleration, overcurrent during constant speed, overcurrent during deceleration, overvoltage during acceleration,
overvoltage during constant speed, overvoltage during deceleration, inverter protection thermal operation, motor protection thermal
operation, heatsink overheat, input phase loss (*5, *6), output side earth (ground) fault overcurrent at start (*5), output phase loss,
Protective Functions
external thermal relay operation (*5), PTC thermistor operation (*5), parameter error, PU disconnection, retry count excess (*5), CPU
fault, brake transistor alarm, inrush resistance overheat, analog input error, stall prevention operation, output current detection value
exceeded (*5), safety circuit fault
Fan alarm (*3), overcurrent stall prevention, overvoltage stall prevention, PU stop, parameter write error, regenerative brake prealarm
Warning Functions (*5), electronic thermal relay function prealarm, maintenance output (*5), undervoltage, operation panel lock, password locked,
inverter reset, safety stop
Surrounding Air Temperature -10°C to +50°C (14°F to 122°F) (non-freezing) (*4)
Environment

Ambient Humidity 90%RH maximum (non-condensing)


Storage Temperature (*2) -20°C to +65°C (-4°F to 149°F)
Atmosphere Indoors (without corrosive gas, flammable gas, oil mist, dust and dirt, etc.)
Altitude/Vibration Maximum 1000m (3280.80 feet) above sea level, 5.9m/s2 or less at 10 to 55Hz (directions of X, Y, Z axes)
Notes:
1. The braking torque indicated is a short-duration average torque (which varies with motor loss) when the motor alone is decelerated from 60Hz in the shortest time and is not a continuous regenerative
torque. When the motor is decelerated from the frequency higher than the base frequency, the average deceleration torque will reduce. Since the inverter does not contain a brake resistor, use the
optional brake resistor when regenerative energy is large. A brake unit (FR-BU2) may also be used.
2. Temperatures applicable for a short time, e.g. in transit.
3. As the FR-D720-042 or less, FR-D740-022 or less, FR-D720S-042 or less, FR-D710W-042 or less are not provided with the cooling fan, this alarm does not function.
4. When using the inverters at the surrounding air temperature of 40°C (104°F) or less, the inverters can be installed closely attached (0cm clearance).
5. This protective function does not function in the initial status.
6. This protective function is available with the three-phase power input specification model only.

400
D700 Series Terminal Connection Diagram

*1. DC reactor (FR-HEL) *6 Terminal P1 is not available for single-


Sink logic When connecting a DC reactor, remove the phase 100V power input model.
jumper across P1-P/+
Main circuit terminal Single-phase 100V power input model is not *7 A brake transistor is not built-in to the
Control circuit terminal compatible with DC reactor. FR-D720-008, 014 and FR-D720S-008,
Single-phase power input 014 and FR-D710W-008, 014.
Brake unit
MCCB MC (Option)
*8 Brake resistor (FR-ABR, MRS type, MYS
Single-phase *1 type)
R/L1 R
Install a thermal relay to prevent an
AC power Earth
S/L2 (Ground) *8 overheat and burnout of the brake resistor.
supply (The brake resistor can not be connected
Jumper PR N/- to the FR-D720-008, 014 and FR-D720S-
008, 014 and FR-D710W-008, 014.)
P1 P/+ *7
MCCB MC
*6 U Motor
Three-phase R/L1
Inrush current
AC power S/L2 V
limit circuit IM
supply T/L3 W

Earth Main circuit


(Ground) Earth (Ground)

Control circuit
Control input signals (No voltage input allowed) C Relay output
Forward STF
Terminal functions vary rotation start Terminal functions vary
B by Pr. 192 A,B,C terminal
with the input terminal Reverse STR Relay output
assignment (Pr. 178 to rotation start (Fault output) function selection
A
Pr. 182) RH
High
speed
RM Open collector output
Multi-speed selection Middle
speed
SOURCE

RUN Terminal functions vary by


SINK

*2 When using terminals PC-


Low RL
SD as a 24VDC power Running Pr. 190 RUN terminal function
supply, take care not to
speed selection
SD
short across terminals 24V
PC-SD. Contact input common
PC *2 SE Open collector output common
24VDC power supply Sink/source common
(Common for external power supply transistor)

Frequency setting signals (Analog)


3 10(+5V)
*3 Terminal input specifications Frequency
can be changed by analog setting
input specifications 2 2 0 to 5VDC *3
switchover (Pr. 73). potentiometer (0 to 10VDC) AM (+)
Terminal 10 and terminal 2 1/2W1kΩ Analog signal output
are used as PTC input *5 (0 to 10VDC)
terminal (Pr. 561). 5(Analog common) 5 (-)
1
*4 Terminal input
specifications can be Terminal 4 PU
changed by analog input input (+) 4 4 to 20mADC connector
specifications switchover (Current (-) 0 to 5VDC
0 to 10VDC *4
(Pr. 267). Set the
voltage/current input input)
switch in the "V" position
to select voltage input (0 V I
to 5V/0 to10V) and "I"
(initial value) to select Voltage/current
current input (4 to 20mA). input switch *4
*5 It is recommended to use 2W1kΩ
when the frequency setting signal
is changed frequently.

Safety stop signal Shorting


wire S1 SO
Output shutoff (Line 1) For manufacturer
Safety setting
monitor output *8
Output shutoff
S2 *8 Common terminal of
Output shutoff (Line 2) circuit terminal SO is terminal SC.
SC (Connected to terminal SD
Common terminal inside of the inverter.)

Terminal Block Layout


Recommended wire size:
0.3mm² 0.75mm²

Mitsubishi Electric Automation | Variable Frequency Drives 401


n VARIABLE FREQUENCY DRIVES
D700 Series Options
Model Number Description Notes Stocked Item
FR-PU07 Alpha-Numeric multi-language keypad S
FR-PA07 Panel mount basic keypad S
FR-CONFIGURATOR Programming and diagnostic software S
SC-FRPC Serial communications cable S
FR-CB201 Remote cable for connecting keypad 1 meter cable S
FR-CB203 Remote cable for connecting keypad 3 meter cable S
FR-CB205 Remote cable for connecting keypad 5 meter cable S
FR-ABR-_ _ K External braking resistor S
FR-RJ45-HUB4 Serial Network Hub - 2 Stations -
FR-RJ45-HUB10 Serial Network Hub - 8 Stations -
FR-RJ45-TR Terminating Resistor for FR-RJ45-HUB -
Note: _ _ represents KW rating.

Input Radio Noise Filter Brake Resistors


This filter is connected to the input of the drive and helps to reduce W 500 +200
radiated noise in the radio frequencies. W1 ±1
W2 A1
Leakage

B1
Drive Kit Model Dimensions mm (in)
φd1
Current Stocked Item
Voltage Number L W D A1
(mA) A2

5.3
208 - 230 FR-BIF 4 58 (2.3) 44 (1.8) 42 (1.7) S Glass-braided cable

B2
2.0mm2 white
460 FR-BIF-H 4 58 (2.3) 44 (1.8) 42 (1.7) - φd2
D
A2

H
Line Noise Filter

2.5
Provides a toroid for line noise reduction. Brake Resistor Model Dimensions (mm)
Kit Model Dimensions mm (in) W W1 W2 D H
Drive Hp Stocked Item
Number L W D 200V Class
FR-ABR-0.4K 140 125 100 40 21
0.5 - 5 FR-BSF01 110 (4.33) 22.5 (0.89) 65 (2.56) S
FR-ABR-0.75K 215 200 175 40 21
0.5 - 75 FR-BLF 180 (7.07) 31.5 (1.24) 83 (3.27) S FR-ABR-2.2K 240 225 200 50 26
FR-ABR-3.7K 215 200 175 61 33
FR-ABR-5.5K 335 320 295 61 33
D700 EMC Filters FR-ABR-7.5K 400 385 360 80 40
FR-ABR-11K 400 385 360 100 50
This attachment allows the VFD to be mounted onto the filter.
FR-ABR-15K (*1) 300 285 260 100 50
Model Number Drive Model Stocked Item 400V Class
FFR-CS-050-14A-RF1 D720S-008 to 042 - FR-ABR-H0.4K 115 100 75 40 21
FFR-CS-080-20A-RF1 D720S-070 - FR-ABR-H0.75K 140 125 100 40 21
FR-ABR-H1.5K 215 200 175 40 21
FFR-CS-110-26A-RF1 D720S-100 -
FR-ABR-H2.2K 240 225 200 50 26
FFR-CSH-036-8A-RF1 D740-012 to 036 - FR-ABR-H3.7K 215 200 175 61 33
FFRCSH-080-16A-RF1 D740-050 to 080 - FR-ABR-H5.5K 335 320 295 61 33
FFRMSH-170-30A-RF1 D740-120 to 160 - FR-ABR-H7.5K 400 385 360 80 40
FR-ABR-H11K 400 385 360 100 50
FR-ABR-H15K (*2) 300 285 260 100 50
Notes:
DIN Rail Mounting Attachment 1. For the 15K, connect the two supplied resistors (18 ohms) in parallel
This attachment allows the D700 Series inverter to mount on a 35mm DIN rail. 2. For the H15K, connect the two supplied resistors (18 ohms) in series.

Drive Model
Model Number Stocked Item
D710W D720S D720 D740 D700 Conduit Kits
FR-UDA01 008-025 008-042 008-042 - S
Kit Model Part Number Stocked
FR-UDA02 042 070 070-100 012-080 S
Number FR-D710W- FR-D720S- FR-D720- FR-D740- Item
FR-UDA03 - - 165 - -
FR-E7FN-01 008/014 008/014 008/014 - S
FR-E7FN-02 - - 025 - S
D700 Demonstration Unit FR-E7FN-03 - - 042 - S
FR-E7FN-04 - - 070/100 036 S
Model Number Description Stocked Item
FR-E7FN-06 - - - - S
Includes E720 and D720 1HP, pre-wired digital input FR-E7FN-07 - - 165 - S
VFD-MICRO-DEMO S
switches, led outputs and speed potentiometer
FR-E7FN-08 - - 238/318 120/160 S
Includes 1/2HP motor with quick connection to
VFD-MOTOR-DEMO S FR-E7FN-11 - - - 012/022 -
VFD-MICRO-DEMO
FR-E7FN-12 - - - 050/080 -

402
D700 Heatsink Extension Kits D700 Building Management Options
Kit Model Part Number ETH-1000 XLTR-1000
Stocked Item Network Type / Model
Number (*2, *3) (*2, *3)
FR-D710W- FR-D720S- FR-D720- FR-D740-
BACnet/IP X -
FR-E7CN-02 025 025 025 - S
EtherNet/IP X -
FR-E7CN-03 - 042 042 - S Gateway Modbus/TCP X -
FR-E7CN-04 - 070 070/100 036 to 080 S Communication Profinet IO X -
FR-E7CN-06 - 100 - - S BACnet MS/TP X X
Metasys N2 X X
FR-E7CN-07 - - 165 - S
Stocked Item - -
FR-E7CN-08 042 - 238/318 120/160 S
Notes:
FR-E7CN-11 - - - 012/022 - 1. For additional information, visit www.iccdesigns.com
2. Communication to multiple VFD’s is possible
3. Mounted and powered external to VFD

D700 Series Watt Loss and Efficiency Data


115VAC 1-Phase Input 240VAC 1-Phase Input 240VAC 3-Phase Input 480VAC 3-Phase Input
Model Model Model Model
HP-CT Rated Watts Rated Watts Rated Watts Rated Watts
Number Efficiency Number Efficiency Number Efficiency Number Efficiency
Watts Loss Watts Loss Watts Loss Watts Loss
FR-D710W- FR-D720S- FR-D720- FR-D740-
1/8 008 100 14 86% 008 100 14 86% 008 100 14 86% - - - -
1/4 015 200 20 90% 015 200 20 90% 014 200 20 90% - - - -
1/2 030 400 38 91% 030 400 32 92% 025 400 32 92% 012 400 40 90%
1 050 750 50 93% 050 750 50 93% 042 750 50 93% 022 750 55 93%
2 - - - - 070 1500 80 95% 070 1500 80 95% 036 1500 90 94%
3 - - - - 100 2200 110 95% 100 2200 100 95% 050 2200 100 95%
5 - - - - - - - - 165 3700 160 96% 080- 3700 180 95%
7.5 - - - - - - - - 238 5500 270 95% 120 5500 240 96%
10 - - - -- - - - - 318 7500 360 95% 160 7500 280 96%
General Notes:
1. The amount of heat generated by the inverter is based on one inverter connected to one motor of the same capacity.
2. The amount of heat generated in the above table is the amount of heat generated when the inverter is operated at its rated current.
3. The amount of heat generated will decrease according to the motor load and usage (duty).

D700 Standby Power


115VAC 1-Phase Input 240VAC 1-Phase Input 240VAC 3-Phase Input 480VAC 3-Phase Input
Stand-By Power Stand-By Power Model Stand-By Power Model Stand-By Power
HP-CT Model Number Model Number
Consumption Consumption Number Consumption Number Consumption
FR-D710W- Min Max FR-D720S- Min Max FR-D720- Min Max FR-D740- Min Max
1/8 008 5.5 10.5 008 5.5 10.5 008 5.5 10.5 - - -
1/4 015 5.5 10.5 015 5.5 10.5 014 5.5 10.5 - - -
1/2 030 5.5 10.5 030 5.5 10.5 025 5.5 10.5 012 10.5 15
1 050 5.5 10.5 050 5.5 10.5 042 5.5 10.5 022 10.5 15
2 - - - 070 5.5 14 070 5.5 14 036 10.5 17
3 - - - 100 5.5 14 100 5.5 14 050 10.5 17
5 - - - - - - 165 6 15 080 10.5 17
7.5 - - - - - - 238 13 22.5 120 13.5 22.5
10 - - - - - - 318 13 22.5 160 13.5 22.5
General Notes:
1. The maximum is generated with PC terminal operating 100mA load, external parameter unit, and cooling fan operating.
2. The minimum is generated with no load on PC terminal, no external parameter unit, and cooling fan off.

Mitsubishi Electric Automation | Variable Frequency Drives 403


n VARIABLE FREQUENCY DRIVES
D700 Dynamic Braking

All Mitsubishi Electric VFDs have some inherent braking capability. During controlled deceleration, motor regenerative losses are
dissipated in the motor, wire, and VFD circuitry. The built-in DC injection braking allows for low speed braking and stopping.
When the above capabilities are inadequate for an application, it is necessary to add a power transistor brake unit and resistor unit in
series across the DC bus. Motor regeneration causes the DC bus voltage to increase, and when the voltage exceeds a specified threshold,
the transistor turns on to pass current through the resistor. Motor kinetic energy is converted to heat energy. VFD overcurrent and
overvoltage protective circuits are active at all times, and will fault-trip the VFD if the brake size is inadequate.
Two main factors must be considered when sizing the brake, the effective duty cycle (%ED) and the short time duty rating. The
effective duty cycle is increased when an external resistor is added. It is preferable to profile the effective duty cycle of the units of time.
With this information, the short time duty is known and the %ED can be calculated, as shown in the below example.
%ED = Braking time / total time for complete operating cycle *100

Example: Complete cycle is:


5 sec: Acceleration time to reach set speed
60 sec: Run time at set speed
3 sec: Deceleration time to come to a complete stop
12 sec: Time period motor remains stopped

%ED = 3 / (5 + 60 + 3 + 12) * 100 = 3.6%


The tables shown assume 100% brake torque, when brake torque is represented by its percentage to the rated torque of the applied motor.
Torque (kg.m) = 974 * Power (kW) / Speed (rpm).

240VAC Dynamic Braking Resistor at 100% Braking Torque


Continuous Drive Model
Resistor Kit Model Weight Resistance
Permissible Motor (Hp) D710W and Stocked Item
Number kg (lbs) (Ohms) % ED
Power (W) D720(S)
FR-ABR-0.4K 0.2 (0.5) 200 60 1/2 025 10% S
FR-ABR-0.75K 0.4 (0.9) 100 80 1 042 10% S
FR-ABR-2.2K 0.5 (1.1) 60 120 2 and 3 070 / 100 10% S
FR-ABR-3.7K 0.8 (1.8) 40 155 5 165 10% S
FR-ABR-5.5K 1.3 (2.9) 25 185 7 1/2 238 10% S
FR-ABR-7.5K 2.2 (4.9) 20 340 10 318 10% S

480VAC Dynamic Braking Resistor at 100% Braking Torque


Continuous Drive Model
Resistor Kit Model Weight Resistance
Permissible Motor (Hp) Stocked Item
Number kg (lbs) (Ohms) D740 % ED
Power (W)
FR-ABR-H0.4K 0.2 (0.5) 1200 45 1/2 012 10% S
FR-ABR-H0.75K 0.2 (0.5) 700 75 1 022 10% S
FR-ABR-H1.5K 0.4 (0.9) 350 115 2 036 10% S
FR-ABR-H2.2K 0.5 (1.1) 250 120 3 050 10% S
FR-ABR-H3.7K 0.8 (1.8) 150 155 5 080 10% S
FR-ABR-H5.5K 1.3 (2.9) 110 185 7 1/2 120 10% S
FR-ABR-H7.5K 2.2 (4.9) 75 340 10 160 10% S

404
E700 Series
The cost-effective variable speed control solution for general purpose applications.

• Available in 115V, 240V and 480V up • Standard RS-485 serial communications


to 20HP supporting Modbus® RTU
• Advanced Magnetic Flux Vector Control • Sink / Source selectable I/O
for improved starting torque and smooth • Supports remote I/O function via network
low speed motor operation
• Built-in PID Control
• Auto-tuning allows improved
performance using virtually any • Delivers rated current at 50°C and
manufacturer’s motor 14.5kHz carrier frequency with minimal
de-rating
• All capacities include built-in brake
chopper • 200% overload for 3 seconds
• Safety Stop function meets • 0 to 10V analog output
EN954-1 Category 3 and IEC60204-1 Stop • CC-Link®, DeviceNet™, Profibus-DP,
Category 0 LonWorks®, EtherNet/IP
• USB communications allow fast • Standard 5 year warranty
commissioning and troubleshooting

FR-E720 – 175SC – NA Voltage

115
1 Phase 1/8 – 1 Hp

Symbol Voltage Class Inverter Safety Version 240


1/8 – 3 Hp
1 Phase
E710W* Single-phase 115V class capacity 3 Phase Only
208/230
E720S* Single-phase 240V class Amperage/10 3 Phase 1/8 – 20 Hp

E720 Three-phase 200V class (175 = 460


1/2 – 20 Hp
E740 Three-phase 400V class 17.5A output) 3 Phase

* Contact MEAU for SC Version availablitiy.


Horsepower

E700 Series
Dimensions in inches (mm)
HP Output Amps Model Number Weight Lbs (kg) Stocked Item
Height Width Depth
1-Phase 100~120VAC Input / 3-Phase 200~240VAC Output
1/8 0.8 FR-E710W-008-NA 5.0 (128) 2.7 (68) 3.2 (80.5) 1.1 (0.5) S
1/4 1.5 FR-E710W-015-NA 5.0 (128) 2.7 (68) 4.4 (110.5) 1.3 (0.6) S
1/2 3 FR-E710W-030-NA 5.0 (128) 2.7 (68) 4.5 (112.5) 2.0 (0.9) S
1 5 FR-E710W-050-NA 5.0 (128) 6.7 (170) 6.1 (155) 7.5 (3.4) S
1-Phase 200~240VAC Input / 3-Phase 200~240VAC Output
1/8 0.8 FR-E720S-008-NA 5.0 (128) 2.7 (68) 3.2 (80.5) 1.1 (0.5) S
1/4 1.5 FR-E720S-015-NA 5.0 (128) 2.7 (68) 3.2 (80.5) 1.1 (0.5) S
1/2 3 FR-E720S-030-NA 5.0 (128) 2.7 (68) 6.2 (157.6) 1.3 (0.6) S
1 5 FR-E720S-050-NA 5.0 (128) 4.3 (108) 5.4 (135.5) 3.1 (1.4) S
2 8 FR-E720S-080-NA 5.0 (128) 4.3 (108) 6.4 (161) 3.1 (1.4) S
3 11 FR-E720S-110-NA 5.9 (150) 5.5 (140) 6.2 (155.5) 4.2 (1.9) S
3-Phase 200~240VAC Input & Output
1/8 0.8 FR-E720-008SC-NA S
5.0 (128) 2.7 (68) 3.4 (87) 1.1 (0.5)
1/4 1.5 FR-E720-015SC-NA S
1/2 3 FR-E720-030SC-NA 5.0 (128) 2.7 (68) 4.7 (120) 1.6 (0.7) S
1 5 FR-E720-050SC-NA 5.0 (128) 2.7 (68) 5.5 (139) 2.2 (1.0) S
2 8 FR-E720-080SC-NA S
5.0 (128) 4.3 (108) 5.6 (142) 3.1 (1.4)
3 11 FR-E720-110SC-NA S
5 17.5 FR-E720-175SC-NA 5.0 (128) 6.7 (170) 5.9 (149) 3.8 (1.7) S
7 1/2 24 FR-E720-240SC-NA S
10.3 (260) 7.1 (180) 6.9 (171) 9.5 (4.3)
10 33 FR-E720-330SC-NA S
15 47 FR-E720-470SC-NA S
10.3 (260) 8.7 (220) 7.7 (196) 19.9 (9)
20 60 FR-E720-600SC-NA S
3-Phase 380~480VAC Input & Output
1/2 1.6 FR-E740-016SC-NA S
5.9 (150) 5.5 (140) 4.7 (120) 3.1 (1.4)
1 2.6 FR-E740-026SC-NA S
2 4 FR-E740-040SC-NA S
3 6 FR-E740-060SC-NA 5.9 (150) 5.5 (140) 5.6 (142) 4.2 (1.9) S
5 9.5 FR-E740-095SC-NA S
7 1/2 12 FR-E740-120SC-NA S
5.9 (150) 8.7 (220) 6.0 (153) 7.1 (3.2)
10 17 FR-E740-170SC-NA S
15 23 FR-E740-230SC-NA S
10.3 (260) 8.7 (220) 7.7 (196) 19.9 (9)
20 30 FR-E740-300SC-NA S

Mitsubishi Electric Automation | Variable Frequency Drives 405


n VARIABLE FREQUENCY DRIVES
E700 General Specifications
Soft-PWM control/high carrier frequency PWM control (V/F control, Advanced magnetic flux vector control, General-purpose magnetic
Control Method
flux vector control, Optimum excitation control are available)
Output Frequency Range 0.2 to 400Hz
0.06Hz/60Hz (terminal2, 4: 0 to 10V/10bit)
Frequency Setting Analog Input 0.12Hz/60Hz (terminal2, 4: 0 to 5V/9bit)
Control Specifications

Resolution 0.06Hz/60Hz (terminal4: 0 to 20mA/10bit)


Digital Input 0.01Hz
Analog Input Within ±0.5% of the max. output frequency (25°C ±10°C)
Frequency Accuracy
Digital Input Within 0.01% of the set output frequency
Voltage/Frequency Characteristics Base frequency can be set from 0 to 400Hz, Constant-torque/variable torque pattern can be selected
Starting Torque 200% or more (at 0.5Hz) when Advanced magnetic flux vector control is set (3.7K or less)
Torque Boost Manual torque boost
Accel/Decel Time Setting 0.01 to 360s, 0.1 to 3600s (acceleration and deceleration can be set individually), linear or S-pattern accel/decel modes are available.
DC Injection Brake Operation frequency (0 to 120Hz), operation time (0 to 10s), operation voltage (0 to 30%) can be changed.
Stall Prevention Operation Level Operation current level can be set (0 to 200% adjustable), whether to use the function or not can be selected
Two terminals
Analog Input Terminal 2: 0 to 10V, 0 to 5V can be selected
Frequency Setting Terminal 4: 0 to 10V, 0 to 5V, 4 to 20mA can be selected
Signal The signal is entered from the operation panel or parameter unit.
Digital Input Frequency setting increment can be set.
4 digit BCD or 16bit binary data (when the option FR-A7AX E kit is used)
Start Signal Forward and reverse rotation or start signal automatic self-holding input (3-wire input) can be selected.
The following signals can be assigned to Pr. 178 to Pr.184 (input terminal function selection): multi-speed selection, remote setting,
Input Signal Standard (Control circuit
stop-on contact selection, second function selection, terminal 4 input selection, JOG operation selection, PID control valid terminal,
terminal model: Seven terminals
brake opening completion signal, external thermal input, PU-External operation switchover, V/F switchover, output stop, start self-
Safety stop function model: Six
holding selection, forward rotation, reverse rotation command, inverter reset, PU-NET operation switchover, External-NET operation
terminals)
switchover, command source switchover, inverter operation enable signal, and PU operation external interlock
Operation Specifications

Maximum/minimum frequency setting, frequency jump operation, external thermal relay input selection, automatic restart after
instantaneous power failure operation, forward/reverse rotation prevention, remote setting, brake sequence, second function, multi-
Operational Functions
speed operation, stop-on contact control, droop control, regeneration avoidance, slip compensation, operation mode selection, offline
auto tuning function, PID control, computer link operation (RS-485)
Safety stop function (*1) Safety shutoff signal can be input from terminals S1 and S2. (compliant with EN954-1 Cat.3)
Open Collector
Output Signal Two terminals
Output
Points
Relay Output One terminal
The following signals can be assigned to Pr.190 to Pr.192 (output terminal function selection): inverter operation, upto-frequency,
overload alarm, output frequency detection, regenerative brake prealarm, electronic thermal relay function prealarm, inverter operation
ready, output current detection, zero current detection, PID lower limit, PID upper limit, PID forward/reverse rotation output, brake
Output Signal

Operating Status
opening request, fan alarm, heatsink overheat prealarm, deceleration at an instantaneous power failure, PID control activated, safety
monitor output (*1), safety monitor output2 (*1), during retry, life alarm, current average value monitor, remote output, alarm output,
fault output, fault output 3, and maintenance timer alarm
For Meter
Analog Output 0 to 10VDC: one terminal
Output Points
The following signals can be assigned to Pr.158 AM terminal function selection: output frequency, motor current (steady), output
voltage, frequency setting, motor torque, converter output voltage, regenerative brake duty, electronic thermal relay function load
For Meter
factor, output current peak value, converter output voltage peak value, reference voltage output, motor load factor, PID set point, PID
measured value, output power 0 to 10VDC
The following operating status can be displayed: output frequency, motor current (steady), output voltage, frequency setting,
cumulative energization time, actual operation time, motor torque, converter output voltage, regenerative brake duty, electronic
Operating
thermal relay function load factor, output current peak value, converter output voltage peak value, motor load factor, PID set point,
Status
PID measured value, PID deviation, inverter I/O terminal monitor, I/O terminal option monitor, output power, cumulative power, motor
Indication

Operation Panel
Parameter Unit thermal load factor, and inverter thermal load factor.
(FR-PU07) Fault definition is displayed when the fault occurs and the past 8 fault definitions (output voltage/current/frequency/cumulative
Fault Definition
energization time right before the fault occurs) are stored
Interactive
Function (help) for operation guide (*2)
Guidance
Overcurrent during acceleration, overcurrent during constant speed, overcurrent during deceleration, overvoltage during acceleration,
overvoltage during constant speed, overvoltage during deceleration, inverter protection thermal operation, motor protection thermal
operation, heatsink overheat, input phase failure (*4), output side earth (ground) fault overcurrent at start (*4), output phase failure,
Protective Function
external thermal relay operation (*3), option fault (*3), parameter error, internal board fault, PU disconnection, retry count excess (*4),
CPU fault, brake transistor alarm, inrush resistance overheat, communication error, analog input error, USB communication error,
brake sequence error 4 to 7 (*3), safety circuit fault (*1)
Fan alarm, overcurrent stall prevention, overvoltage stall prevention, PU stop, parameter write error,
Warning Function regenerative brake prealarm (*3), electronic thermal relay function prealarm, maintenance output (*3), undervoltage,
operation panel lock, password locked, inverter reset, safety stop (*1)
Ambient Temperature -10°C to +50°C (14°F to 122°F) (non-freezing) (*5)
Environment

Ambient Humidity 90%RH maximum (non-condensing)


Storage Temperature (*6) -20°C to +65°C (-4°F to 149°F)
Atmosphere Indoors (without corrosive gas, flammable gas, oil mist, dust and dirt etc.)
Altitude/Vibration Maximum 1000m (3280.80 feet) above sea level, 5.9m/s2 or less at 10 to 55Hz (directions of X, Y, Z axes)
Notes:
1. This function is only available for the safety stop function model.
2. This operation guide is only available with option parameter unit (FR-PU07).
3. This protective function does not function in the initial status.
4. This protective function is available with the three-phase power input model only.
5. When using the inverters at the surrounding air temperature of 40°C (104°F) or less, the inverters can be installed closely attached (0cm clearance).
6. Temperatures applicable for a short time, e.g. in transit.

406
E700 Series Terminal Connection Diagram
One-phase 100V power input
Three-phase 200V power input
Three-phase 400V power input

Sink logic
Main circuit terminal *1. DC reactor (FR-HEL)
Control circuit terminal When connecting a DC reactor, remove the *6 A brake transistor is not built-in to the
jumper across P1-P/+ FR-E720-008SC and 015SC, FR-E720S-
Single-phase power input 008SC and 015SC.
Brake unit
MCCB MC (Option)
*7 Brake resistor (FR-ABR, MRS, MYS type)
*1 Install a thermal relay to prevent an
Single-phase R/L1 R
AC power Earth overheat and burnout of the brake resistor.
S/L2 (Ground) *7
supply (The brake resistor can not be connected
Jumper PR N/- to the FR-E720-008SC and 015SC, FR-
E720S-008SC and 015SC.)
MCCB MC P1 P/+ *6
Motor
Three-phase R/L1 U
Inrush current
AC power S/L2 V
limit circuit IM
supply T/L3 W

Earth
(Ground)
Main circuit Earth (Ground)
Control circuit
Safety stop function model
Control input signals (No voltage input allowed)
Forward STF C Relay output
Terminal functions vary rotation start Terminal functions vary
with the input terminal Reverse STR B
Relay output by Pr. 192 A,B,C terminal
assignment (Pr. 178 to rotation start function selection
Pr. 184) RH (Fault output)
High A
speed
Multi-speed selection RM
Middle
speed Open collector output
*2 When using terminals PC-SD Low RL
RUN Terminal functions vary with
as a 24VDC power supply, speed the output terminal assignment
SOURCE

take care not to short across RES Running


SINK

terminals PC-SD. Reset (Pr. 190 and Pr. 191)


SD FU
Contact input common 24V Frequency detection
24VDC power supply PC *2
(Common for external power supply transistor)
Safety stop input common terminal SE Open collector output common
S1 Sink/source common
Safety stop input (Line 1) Output shutoff
S2 circuit
Safety stop input (Line 2)
Shorting wire
Frequency setting signals (Analog) (+)
AM
3 10(+5V) Analog signal output
*3 Terminal input specifications Frequency (0 to 10VDC)
can be changed by analog setting 5 (-)
input specifications 2 2 0 to 5VDC *3
switchover (Pr. 73). potentiometer (0 to 10VDC)
1/2W1kΩ
PU
*4 It is recommended to use 2W1kΩ *4 5(Analog common)
when the frequency setting signal 1 connector
is changed frequently.
Terminal 4 input (+) 4 4 to 20mADC
(Current input) (-) 0 to 5VDC
*5 Terminal input specifications can be changed by analog 0 to 10VDC *5 USB
input specifications switchover (Pr. 267). Set the connector
voltage/current input switch in the "V" position to select
voltage input (0 to 5V/0 to10V) and "I" (initial value) to V I
select current input (4 to 20mA).
To use terminal 4 (initial setting is current input), set "4" Voltage/current
in any of Pr.178 to Pr.184 (input terminal function selection) input switch *5
to assign the function, and turn ON AU signal.

Connector for
plug-in option connection Option connector

Mitsubishi Electric Automation | Variable Frequency Drives 407


n VARIABLE FREQUENCY DRIVES
E700 Series Plug-In Options E700 Series External Options
Model Number Description Stocked Item Model Number Description Stocked Item
FR-A7NC E KIT SC CC-Link Network Option S FR-PU07 Alpha-Numeric multi-language keypad S
FR-A7ND E KIT SC DeviceNet Network Option S Battery powered Alpha-Numeric multi-language
FR-PU07BB-L S
keypad
FR-A7NP E KIT SC Profibus-DP Network Option S
FR-CB20 Keypad extension cable S
FR-A7NL E KIT SC LonWorks Network Option S
SC-FRPC Serial communications cable S
FR-A7AX E KIT SC Additional 16-bit Digital Input S
FR-A7AY E KIT SC Additional Analog & Digital Output S FR-ABR- K External brake resistor S

FR-A7AR E KIT SC Additional Relay Output S FR-RJ45-HUB4 Serial Network Hub - 2 Stations -
Multidrop for Serial FR-RJ45-HUB10 Serial Network Hub - 8 Stations -
FR-E7TR S
Communication
FR-RJ45-TR Terminating Resistor For FR-RJ45-HUB -
Note: FR-E7TR ia not compatible with safety version of E700.
Note: _ _ represents drive kW rating

E700 Dynamic Braking


All Mitsubishi Electric VFDs have some inherent braking capability. During controlled deceleration, motor regenerative losses are
dissipated in the motor, wire, and VFD circuitry. The built-in DC injection braking allows for low speed braking and stopping.
When the above capabilities are inadequate for an application, it is necessary to add a power transistor brake unit and resistor unit in
series across the DC bus. Motor regeneration causes the DC bus voltage to increase, and when the voltage exceeds a specified threshold,
the transistor turns on to pass current through the resistor. Motor kinetic energy is converted to heat energy. VFD overcurrent and
overvoltage protective circuits are active at all times, and will fault-trip the VFD if the brake size is inadequate.
Two main factors must be considered when sizing the brake, the effective duty cycle (%ED) and the short time duty rating. The
effective duty cycle is increased when an external resistor is added. It is preferable to profile the effective duty cycle of the units of time.
With this information, the short time duty is known and the %ED can be calculated, as shown in the below example.
%ED = Braking time / total time for complete operating cycle *100

Example: Complete cycle is:


5 sec: Acceleration time to reach set speed
60 sec: Run time at set speed
3 sec: Deceleration time to come to a complete stop
12 sec: Time period motor remains stopped

%ED = 3 / (5 + 60 + 3 + 12) x 100 = 3.6%


The tables shown assume 100% brake torque, when brake torque is represented by its percentage to the rated torque of the applied motor.
Torque (kg.m) = 974 x Power (kW) / Speed (rpm).

240VAC Dynamic Braking Resistor at 100% Braking Torque


Continuous Drive Model
Resistor Kit Model Weight Resistance
Permissible Motor (Hp) E710W and Stocked Item
Number kg (lbs) (Ohms) % ED
Power (W) E720(S)
FR-ABR-0.4K 0.2 (0.5) 200 60 1/2 030 10% S
FR-ABR-0.75K 0.4 (0.9) 100 80 1 050 10% S
FR-ABR-2.2K 0.5 (1.1) 60 120 2&3 080 / 110 10% S
FR-ABR-3.7K 0.8 (1.8) 40 155 5 175 10% S
FR-ABR-5.5K 1.3 (2.9) 25 185 7 1/2 240 10% S
FR-ABR-7.5K 2.2 (4.9) 20 340 10 330 10% S
FR-ABR-11K 3.4 (7.5) 13 560 15 470 6% S
FR-ABR-15K 2.4 (5.3) x 2 9 (18 / 2) 805 20 600 6% S
(2 resistors in parallel)

480VAC Dynamic Braking Resistor at 100% Braking Torque


Continuous Drive Model
Resistor Kit Model Weight Resistance
Permissible Motor (Hp) Stocked Item
Number kg (lbs) (Ohms) E740 % ED
Power (W)
FR-ABR-H0.4K 0.2 (0.5) 1200 45 1/2 016 10% S
FR-ABR-H0.75K 0.2 (0.5) 700 75 1 026 10% S
FR-ABR-H1.5K 0.4 (0.9) 350 115 2 040 10% S
FR-ABR-H2.2K 0.5 (1.1) 250 120 3 060 10% S
FR-ABR-H3.7K 0.8 (1.8) 150 155 5 095 10% S
FR-ABR-H5.5K 1.3 (2.9) 110 185 7 1/2 120 10% S
FR-ABR-H7.5K 2.2 (4.9) 75 340 10 170 10% S
FR-ABR-H11K 3.4 (7.5) 52 530 15 230 6% S
FR-ABR-H15K 2.4 (5.3) x 2 36 (18 x 2) 870 20 300 6% S
(2 resistors in series)

408
Brake Resistors
Dimensions (mm) W 500 +200
Brake Resistor Model
W W1 W2 D H W1 ±1
200V Class W2 A1

B1
FR-ABR-0.4K 140 125 100 40 21 φd1
FR-ABR-0.75K 215 200 175 40 21 A2 A1

5.3
FR-ABR-2.2K 240 225 200 50 26
FR-ABR-3.7K 215 200 175 61 33 Glass-braided cable

B2
FR-ABR-5.5K 335 320 295 61 33 2.0mm2 white
φd2
FR-ABR-7.5K 400 385 360 80 40 D
A2
FR-ABR-11K 400 385 360 100 50

H
FR-ABR-15K (*1) 300 285 260 100 50
400V Class

2.5
FR-ABR-H0.4K 115 100 75 40 21
FR-ABR-H0.75K 140 125 100 40 21
FR-ABR-H1.5K 215 200 175 40 21
FR-ABR-H2.2K 240 225 200 50 26
FR-ABR-H3.7K 215 200 175 61 33
FR-ABR-H5.5K 335 320 295 61 33
FR-ABR-H7.5K 400 385 360 80 40
FR-ABR-H11K 400 385 360 100 50
FR-ABR-H15K (*2) 300 285 260 100 50
Notes:
1. For the 15K, connect the two supplied resistors (18 ohms) in parallel.
2. For the H15K, connect the two supplied resistors (18 ohms) in series.

Input Radio Noise Filter


E740 EMC Filters
This filter is connected to the input of the drive and helps to reduce
This attachment allows the VFD to be mounted onto the filter.
radiated noise in the radio frequencies.
Model Number Drive Model Stocked Item
Leakage Dimensions mm (in)
Drive Kit Model Stocked
Current FFR-MSH-040-8A-RF1 E740-016 to 040 -
Voltage Number L W D Item
(mA)
FFRMSH-095-16A-RF1 E740-060/095 -
208 - 230 FR-BIF 4 58 (2.3) 44 (1.8) 42 (1.7) S
FFRMSH-170-30A-RF1 E740-120/170 -
460 FR-BIF-H 4 58 (2.3) 44 (1.8) 42 (1.7) -
FFRMSH-300-50A-RF1 E740-230/300 -

Line Noise Filter


Provides a toroid for line noise reduction. Building Management Options
Dimensions mm (in) Stocked Internal Mount - Powered by VFD
Drive Hp Kit Model Number External Mount
L W D Item Safety Version Regular Version
Network Type / Model FR-A7N- FR-A7N- FR-A7N- FR-A7N- ETH- XLTR-
0.5 - 5 FR-BSF01 110 (4.33) 22.5 (0.89) 65 (2.56) S ETH XLT ETH XLT 1000 1000
0.5 - 75 FR-BLF 180 (7.07) 31.5 (1.24) 83 (3.27) S (*1, *2) (*1,*3,) (*1,*3) (*1,*3,) (*4,*5,) (*4,*5)
BACnet/IP X - X - X -
EtherNet/IP X - X - X -
Communication

DIN Rail Mounting Attachment Modbus TCP X - X - X -


Gateway

PROFINET IO X - X - X -
This attachment allows the E700 Series inverter to mount on a 35mm BACnet MS/TP - X - X X X
DIN rail. Metasys N2 - X - X X X
Drive Model Siemens FLN - X - X - -
Model Number Stocked Item Stocked Item S S S S - -
E720 (*1)
Notes:
FR-UDA01 008-050 S For additional information, visit www.iccdesigns.com
1. Cable E700-NET-CBL required accessory
FR-UDA02 080-110 S 2. Deeper cover required A7A-EKITCVR-SCSP
3. Deeper cover A7A-EKITCVR-SC required accessory
FR-UDA03 175 - 4. Communication to multiple VFDs is possible
5. Mounted and powered external to VFD
Notes:
1. Not available for 400V models.

Mitsubishi Electric Automation | Variable Frequency Drives 409


n VARIABLE FREQUENCY DRIVES
Installation Interchange Attachment
This attachment allows the E700 Series inverter to be mounted using the installation holes from the previous series VFDs.
Installation Model Previous Model
Model Number Stocked Item
E700 Series E500 Series A0x4 Series Z024 Series A200E Series
E720-008 FR-A024-0.1K-UL FR-Z024-0.1K-UL -
E720-015 FR-A024-0.2K-UL FR-Z024-0.2K-UL -
FR-E5T-10 S
E720-030 FR-A024-0.4K-UL FR-Z024-0.4K-UL -
E720-050 FR-A024-0.75K-UL - -
E720-050 - FR-Z024-0.75K-UL -
FR-E5T-11 -
E720-080 FR-A024-1.5K-UL FR-Z024-1.5K-UL -
E720-110 FR-A024-2.2K-UL FR-Z024-2.2K-UL -
FR-E5T Direct -
E720-175 FR-A024-3.7K-UL FR-Z024-3.7K-UL -
Replacement
E720-240 - - FR-A220E-5.5K-UL
FR-E5T-02 -
E720-330 - - FR-A220E-7.5K-UL
E740-016 FR-A044-0.4K-UL - -
Direct Attachment -
E740-026 FR-A044-0.75K-UL - -
E740-040 FR-A044-1.5K-UL - -
FR-E5T-14 E740-060 FR-A044-2.2K-UL - - -
E740-095 FR-A044-3.7K-UL - -

E700 Installation Interchange Attachment


This attachment allows the E700 Series inverter to be mounted at a 90° angle so that the depth is reduced to 80 mm.
Installation Model Previous Model
Model Number Stocked item
E700 Series E500 Series A0x4 Series Z024 Series
E720-030 FR-A024-0.4K-UL FR-Z024-0.4K-UL -
FR-E5T-L Direct Replacement
E720-050 FR-A024-0.75K-UL - -

E700 Series Watt Loss and Efficiency Data


115VAC 1-Phase Input 240VAC 1-Phase Input 240VAC 3-Phase Input 480VAC 3-Phase Input
HP-CT Part Part Part Part
Number Rated Watts Rated Watts Rated Watts Rated Watts
Efficiency Number Efficiency Number Efficiency Number Efficiency
Watts Loss Watts Loss Watts Loss Watts Loss
FR-E710W- FR-E720S- FR-E720- FR-E740-
1/8 008 100 14 86% 008 100 14 86% 008 100 14 86% - - - -
1/4 015 200 20 90% 015 200 20 90% 015 200 20 90% - - - -
1/2 030 400 38 91% 030 400 32 92% 030 400 32 92% 016 400 45 89%
1 050 750 50 93% 050 750 50 93% 050 750 50 93% 026 750 50 93%
2 - - - - 080 1500 80 95% 080 1500 80 95% 040 1500 85 94%
3 -- - - - 110 2200 110 95% 110 2200 100 95% 060 2200 100 95%
5 - - - - - - - - 175 3700 160 96% 095 3700 160 96%
7.5 - - - - - - - - 240 5500 290 95% 120 5500 310 94%
10 - - - - - - - - 330 7500 380 95% 170 7500 420 94%
15 - - - - - - - - 470 11000 520 95% 230 11000 560 95%
20 - - - - - - - - 600 15000 600 96% 300 15000 640 96%
General Notes:
1. The amount of heat generated by the inverter is based on one inverter connected to one motor of the same capacity.
2. The amount of heat generated in the above table is the amount of heat generated when the inverter is operated at its rated current.
3. The amount of heat generated will decrease according to the motor load and usage (duty).

Conduit Kits E700 Heatsink Extension Kits


Model Number Description Stocked Item Model Number Description Stocked Item
FR-E7FN-01 Conduit kit for E720-008/015 S FR-E7CN-02 Heatsink Extension kit for E720-030 S
FR-E7FN-02 Conduit kit for E720-030 S FR-E7CN-03 Heatsink Extension kit for E720-050 S
FR-E7FN-03 Conduit kit for E720-050 S FR-E7CN-04 Heatsink Extension kit for E720-080/110 S
FR-E7FN-04 Conduit kit for E720-080/110 S FR-E7CN-05 Heatsink Extension kit for E740-016/026 S
FR-E7FN-05 Conduit kit for E740-016/026 S FR-E7CN-06 Heatsink Extension kit for E740-040/060/090 S
FR-E7FN-06 Conduit kit for E740-040/060/090 S FR-E7CN-07 Heatsink Extension kit for E720-175 S
FR-E7FN-07 Conduit kit for E720-175 S FR-E7CN-08 Heatsink Extension kit for E740-120/170 S
FR-E7FN-08 Conduit kit for E740-120/170 S FR-E7CN-09 Heatsink Extension kit for E720-240/330 S
FR-E7FN-09 Conduit kit for E720-240/330 S Heatsink Extension kit for E720-470/600
FR-A7CN02 S
E740-230/300
Conduit kit for E720-470/600
FR-E7FN-10 S
E740-230/300

E700 Demonstration Unit


Model Number Description Stocked Item
VFD-MICRO-DEMO Includes E720 and D720 1HP, pre-wired digital input switches, led outputs and speed potentiometer S
VFD-MOTOR-DEMO Includes 1/2HP motor with quick connection to VFD-MICRO-DEMO S

410
E560 Series
The cost-effective variable speed control solution for general purpose applications.

• Up to 10 Hp at 600VAC • UL and cUL listed / CE marked


• Advanced Magnetic Flux Vector Control • Open-network communication options
• Auto-tuning - DeviceNet
• 50°C maximum ambient temperature - CC-Link
• RS-485 serial communication (standard) - Profibus DP
• Selectable cooling fan operation mode • Brake Transistor
• Built-in PID control
• Adjustable carrier frequency (0.7kHz to
14.5kHz)
• Optional keypad interface (FR-PA02-02)
• Compatible with FR-PU04 user interface

FR-E560 – 3.7 K – NA

Voltage
Symbol Voltage Class Inverter
capacity
E560 Three-phase 600V class “kW” 600 1 – 10 Hp

Horsepower

E560 Series
Rating (CT & VT) IP20 Open Chassis Dimensions
Output Current Stocked Item
Hp Model Number H x W x D mm (in) Weight kg (lbs)
Amps
3-Phase 575 - 600VAC Input / Output
1 1.7 FR-E560-0.75K-NA 150 x 140 x 136 (5.9 x 5.5 x 5.4) 1.8 (4.0) S
2 2.7 FR-E560-1.5K-NA 150 x 140 x 136 (5.9 x 5.5 x 5.4) 2.0 (4.7) S
3 4.0 FR-E560-2.2K-NA 150 x 140 x 136 (5.9 x 5.5 x 5.4) 2.0 (4.7) S
5 6.1 FR-E560-3.7K-NA 150 x 220 x 148 (5.9 x 8.7 x 5.8) 3.8 (8.4) S
7.5 9.0 FR-E560-5.5K-NA 150 x 220 x 148 (5.9 x 8.7 x 5.8) 3.8 (8.4) S
10 12 FR-E560-7.5K-NA 150 x 220 x 148 (5.9 x 8.7 x 5.8) 3.8 (8.4) S

Mitsubishi Electric Automation | Variable Frequency Drives 411


n VARIABLE FREQUENCY DRIVES
E560 General Specifications
Soft-PWM control / high carrier frequency PWM control can be selected. V / F control or general-purpose magnetic
Control Method
flux vector control can be selected.
Output Frequency Range 0.2 to 400Hz (starting frequency variable between 0 and 60Hz)
Analog Input Across terminals 2-5: 1/500 of maximum set frequency (5VDC input), 1/1000 (10VDC, 4-20mADC input)
Frequency Control
Digital Input 0.01Hz (less than 100Hz), 0.1Hz (100Hz or more) when digital setting is made using the control panel
Analog Input Within ±0.5% of maximum output frequency (25°C ±10°C) / 59°F to 95°F
Frequency Precision
Digital Input Within 0.01% of set output frequency when setting is made from control panel
Control Specifications

Voltage / Frequency Characteristics Base frequency set as required between 0 and 400Hz. Constant torque or variable torque pattern can be selected
150% or more (at 1Hz), 200% or more (at 3Hz) when general-purpose magnetic flux vector control or slip
Starting Torque
compensation is selected
Torque Boost Manual torque boost, 0 to 30% may be set
0.01, 0.1 to 3600 sec. (accel. and decel. can be set individually), linear or S-pattern accel./decel. mode can be
Acceleration / Deceleration Time Setting
selected
0.1K, 0.2K...150% or more, 0.4K, 0.75K... 00% or more, 1.5K...50% or more, 2.2K, 3.7K, 5.5K, 7.5K ... 20% or
Regenerative
Braking Torque more (*1)
DC Dynamic Brake Operation frequency (0 to 120Hz), operation time (0 to 10 s), operation voltage (0 to 30%) variable
Stall Prevention Operation Level Operation current level can be set (0 to 200% variable), presence or absence can be selected
Voltage Stall Prevention Operation Level Operation level is fixed, presence or absence can be selected
Fast-Response Current Limit Level Operation level is fixed, presence or absence can be selected
Frequency Setting Analog Input 0 to 5VDC, 0 to 10VDC, 4 to 20mADC
Signal Digital Input Entered from control panel (FR-PA02-02)
Starting Signal Forward and reverse rotation, start signal automatic self-holding input (3-wire input) can be selected
Alarm Reset Used to reset alarm output provided when protective function is activated
Up to 15 speeds can be selected. (Each speed can be set between 0 and 400Hz, running speed can be changed
Multi-Speed Selection
during operation from the control panel)
Used to select second functions (accel. time, decel. time, torque boost, freq., electronic overcurrent
Second Function Selection
protection)
Output Stop Instantaneous shut-off of inverter output (frequency, voltage)
Current Input Selection Used to select input of frequency setting signal 4 to 20mADC (terminal 4)
Use
Input Signals

Start Signal Automatic Self-Holding Selection Used to select start signal automatic self-holding input(3-wire input) Pr. 180
External Thermal Relay Input Thermal relay contact input for use when the inverter is stopped by the external thermal relay to
Pr. 183
PU Operation-External Operation Switching Used to switch between PU operation and external operation from outside the inverter
for
V/F-General-Purpose Magnetic Flux Switching Used to switch between V/F control and general-purpose magnetic flux vector from outside the inverter selection.
Maximum/minimum frequency setting, frequency jump operation, external thermal relay input
selection, automatic restart operation after instantaneous power failure, forward/reverse rotation
Operation Functions
prevention, slip comp., operation mode selection, off-line auto tuning function, PID control, computer
link operation (RS-485)
2 open collector output signals can be selected from inverter running, up to frequency, frequency detection,
overload alarm, zero current detection, output current detection, PID upper limit, PID lower limit, PID forward/
Operation Status
reverse rotation, operation ready, minor fault and alarm, and 1 contact output (230VAC 0.3A, 30VDC 0.3A)
Output Signals can be selected
1 signal can be selected from output frequency, motor current and output voltage. Pulse train output
For Meter
(1440 pulses/second/full scale)
Operating Status Output voltage, output current, set frequency, running
Display

Control Panel Display


Alarm Definition Alarm definition is displayed when protective function is activated. 4 alarm definitions are stored
LED Display Power application (POWER)
Overcurrent shut-off (during acceleration, deceleration, constant speed), regenerative overvoltage shut-off,
undervoltage (*2) , instantaneous power failure (*2), overload shut-off (electronic overcurrent protection), brake
Protective And Warning Functions
transistor alarm, output short circuit, stall prevention, brake resistor overheat protection, fan overheat, fan failure,
parameter error, PU disconnection, ground fault protection
Ambient Temperature Constant torque: -10°C to +50°C (non-freezing) 14°F to 122°F
Ambient Humidity 90%RH or less (non-condensing)
Environment

Storage Temperature (*3 ) -20°C to +65°C / -4°F to 149°F


Atmosphere Indoors, no corrosive and flammable gases, oil mist, dust and dirt
Maximum 1000m (3300 ft.) above sea level for standard operation. After that derate by 3% for every extra 500m
Altitude
up to 2500m (91%)
Vibration 5.9 m/s2 (0.6G max.) based on JIS C 0911
Notes:
1. The braking torque indicated is a short-duration average torque (which varies with motor loss) when the motor alone is decelerated from 60Hz in the shortest time and is not a continuous regenerative torque.
When the motor is decelerated from the frequency higher than the base frequency, the average deceleration torque will reduce. Since the inverter does not contain a brake resistor, use the optional brake
resistor when regenerative energy is large. (The optional brake resistor cannot be used with 0.1K and 0.2K.) A brake unit (BU) may also be used.
2. When undervoltage or instantaneous power failure has occurred, alarm display or alarm output is not provided but the inverter itself is protected. Overcurrent, regenerative overvoltage or other protection may
be activated at power restoration according to the operating status (load size, etc.).
3. Temperature applicable for a short period in transit, etc.

412
E500 Series Terminal Connection Diagram Terminal Block Layout
MCCB MC Motor 600V class
3-phase AC R(L 1) U RH A
V IM
power supply S(L2) W RM B
T(L 3 ) Ground
24VDC power output and RL C
external transistor common PC P1 Jumper MRS 10
Note 4 Remove this jumper when RES 2
(+)P
using the optional power-factor SD 5
PR improving DC reactor. AM 4
Forward rotation start STF
(-)N PC SD
Brake resistor connection
Reverse rotation start STR SE STF
High RH RUN STR
Multi-speed selection A FU SD
Middle RM
B Alarm
Low RL
output
Output stop MRS C

Reset RES
Contact input common SD RUN Running
Note 3
FU Frequency detection Open
Control input signals
(No voltage input allowed) SE Open collector output common collector outputs
Note 2 Sink/source common
Frequency setting signals (Analog)

(Note 1) 3 10(+5V)
Frequency 2
2 0 to 5VDC Selected
setting 0 to 10VDC
potentiometer 1 5(Common)
1/2W1kΩ Current input(-) Note 3
SD
4 to 20mADC(+) 4(4 to 20mADC) Note 2
AM (+) Analog signal
When using current input as the output
frequency setting signal, set "4" in 5 (- )
any of Pr.180 to Pr.183 (input (0 to 10VDC)
terminal function selection) and PU connector Ground Main circuit terminal
assign AU (current input selection) (RS-485) Control circuit input terminal
to any of terminal RH, RM, RL, or
MRS, then turn the AU signal on. Control circuit output terminal
Notes:
1. If the potentiometer is to be operated often use a 2W1kΩ potentiometer.
2. Terminals SD and SE are electrically isolated.
3. Terminals SD and 5 are common. Do not connect them to each other or to ground.
4. To avoid damage to the VFD, do not allow a short circuit between terminals PC and SD. If they are shorted, the VFD will be damaged

E500 Series Options


Model Number Description Notes Stocked Item
FR-PA02-02 Keypad for E500 VFD For mounting on E500 VFD S
FR-E5P Keypad Panel Mounting Adapter For use only on FR-PA02-02 and FR-CB20 S
FR-DU04 LED Parameter Unit Also used with A500(L). S
FR-PU04 LCD Parameter Unit Also used with A500(L). S
FR-E5ND E560 DeviceNet Interface Plug-in Option. Not for use with E520 or E510W. -
FR-E5NP E560 Profibus DP Interface Plug-in Option. Not for use with E520 or E510W. S
FR-E5NC E560 CC-Link Interface Plug-in Option. Not for use with E520 or E510W. -
FR-E5NL E560 LonWorks Interface Plug-in Option. Not for use with E520 or E510W. -
FR-CB201 Remote cable 1m cable S
FR-CB203 Remote Cable 3m cable S
FR-CB205 Remote Cable 5m cable S
SH(NA)3193 FR-A500 / E500 Technical Manual Only available for download. -
IB(NA)0600003 FR-E5NC, CC-Link Instruction Manual Only available for download. -
IB(NA)0600006 FR-E5ND, DeviceNet Instruction Manual Only available for download. -
IB(NA)0600007 FR-E5NP, Profibus Instruction Manual Only available for download. -
IB(NA)0600204 FR-E560 Instruction Manual Only available for download. -
SC-FRPC Serial Communication Cable S

Mitsubishi Electric Automation | Variable Frequency Drives 413


n VARIABLE FREQUENCY DRIVES
F700 Series
The truly fantastic specifications of the F700, make this VFD from Mitsubishi Electric an absolute must for your drive systems.

• NEMA 1 UL Type 1 Enclosure Designs: • Energy Savings: Optimum


Drive can be mounted as a stand-alone Excitation Control
unit where required. (Plenum rated) • 3 user programmable skip frequencies
• Built-in BACnet MS/TP or Modbus RTU • Windmill start: Catch a reverse
communications spinning load
• Built-in PLC; programs using • Pre-charge mode
GX Developer
• PID sleep mode
• Two I/O cards can be installed
simultaneously • Second PID function
• Remote I/O capability: All the drive I/O can • Regeneration avoidance
be read or controlled over a network • Built-in EMC filter: Conforms to
• Optional FR-PU07-01 keypad can be EN61800-3 2nd environmental
mounted remotely, display HAND/AUTO, • UL Listed for single phase input
and display the value of three monitors

Voltage

208/230 3/4 – 200 Hp

480 3/4 – 1000 Hp

Horsepower

F700 Ratings 200-240V Class


Input: 1 Phase/3 Phase - Output Voltage: 3 Phase 200-240V at 60Hz
Voltage Tolerance: 170-264V at 60Hz Available Braking Torque: 15% Torque Continuous
SLD (40°C) LD
110% OL / 1min 120% OL / 1min Protective
Model Number (*4) Frame Size Cooling Method Stocked Item
Rating
120% OL / 3 sec 150% OL / 3 sec
Hp (*1) FLA Hp (*1) FLA
1 4.6 1 4.2 FR-F720-00046-NA A S
Self Cooling
2 7.7 2 7 FR-F720-00077-NA B S
3 10.5 3 9.6 FR-F720-00105-NA C S
5 16.7 5 15.2 FR-F720-00167-NA C S
7.5 25 7.5 23 FR-F720-00250-NA C UL Type 1 - S
10 34 10 31 FR-F720-00340-NA D Plenum Rated S
15 49 15 45 FR-F720-00490-NA D S
20 63 20 58 FR-F720-00630-NA E S
25 77 25 70 FR-F720-00770-NA F S
30 93 30 85 FR-F720-00930-NA F S
40 125 40 114 FR-F720-01250-NA F S
Forced Air
50/60 154 50 140 FR-F720-01540-NA G S
Cooled IP00 (*2)
60 187 60 170 FR-F720-01870-NA H S
75 233 75 212 FR-F720-02330-NA H S
40 125 40 114 FR-F720-01250-NAN1 F -
50/60 154 50 140 FR-F720-01540-NAN1 G -
NEMA 1
60 187 60 170 FR-F720-01870-NAN1 H -
75 233 75 212 FR-F720-02330-NAN1 H -
100/125 316 100 288 FR-F720-03160-NA K S
150 380 125 346 FR-F720-03800-NA K IP00 (*2) S
200 475 150 432 FR-F720-04750-NA K -
Notes: See next page.

414
F700 Ratings 480V Class
Input: 1 Phase / 3 Phase • Output Voltage: 3 Phase 380-480V at 50/60Hz
Voltage Tolerance: 323-528V at 50/60Hz • Available Braking Torque: 15% Torque Continuous
SLD (40°C) LD

110% OL / 1min 120% OL / 1min Frame Cooling Protective Stocked


Model Number (*4)
120% OL / 3 sec 150% OL / 3 sec Size Method Rating Item

Hp (*1) FLA Hp (*1) FLA


1 2.3 1 2.1 FR-F740-00023-NA C S
2 3.8 2 3.5 FR-F740-00038-NA C S
3 5.2 3 4.8 FR-F740-00052-NA C Self Cooling S
5 8.3 5 7.6 FR-F740-00083-NA C S
7.5 12.6 7.5 11.5 FR-F740-00126-NA C S
UL Type 1 -
10 17 10 16 FR-F740-00170-NA D S
Plenum rated
15 25 15 23 FR-F740-00250-NA D S
20 31 20 29 FR-F740-00310-NA E S
25 38 25 35 FR-F740-00380-NA E S
30 47 30 43 FR-F740-00470-NA F S
40 62 40 57 FR-F740-00620-NA F Forced Air S
50/60 77 50 70 FR-F740-00770-NA G Cooled S
60 93 60 85 FR-F740-00930-NA H IP00 (*3) S
75 116 75 106 FR-F740-01160-NA H S
50/60 77 50 70 FR-F740-00770-NAN1 G -
60 93 60 85 FR-F740-00930-NAN1 H NEMA 1 -
75 116 75 106 FR-F740-01160-NAN1 H -
Notes: See below.

Input: 1 Phase / 3 Phase • Output Voltage: 3 Phase 380-480V at 50/60Hz • Voltage Tolerance: 323-550V at 50/60Hz
Available Braking Torque: 15% Torque Continuous • DC Link Choke is Included With The VFD

SLD (40°C) LD

110% OL / 1min 120% OL / 1min


Model Number Frame Protective Stocked
Fan
(*4) Size Rating Item
120% OL / 3 sec 150% OL / 3 sec

Hp (*1) FLA Hp (*1) FLA

100/150 180 100 144 FR-F740-01800-NA H S


150 216 150 180 FR-F740-02160-NA J S
200 260 150 216 FR-F740-02600-NA J S
250 325 200 260 FR-F740-03250-NA K S
300 361 250 325 FR-F740-03610-NA K S
IP00 (*2)
350 432 300 361 FR-F740-04320-NA L S
400 481 350 432 FR-F740-04810-NA L S
Forced Air
450 547 400 481 FR-F740-05470-NA M S
Cooled
500 610 450 547 FR-F740-06100-NA M S
550 683 500 610 FR-F740-06830-NA M S
650 770 550 683 FR-F740-07700-NA N S
700 866 650 770 FR-F740-08660-NA N S
800 962 700 866 FR-F740-09620-NA P IP000 (*3) S
900 1094 800 962 FR-F740-10940-NA P -
1000 1212 900 1094 FR-F740-12120-NA P -
Notes:
1. Motor ratings shown are intended as guidelines only - based on 4 pole standard induction motors.
2. NEMA 1 conduit adapter option required for types 01250 - 04750 200V class product.
3. NEMA 1 conduit adapter option required for types 00770 - 06830 400V class product.
4. For single phase input, derate output current by 40% (Models up to F720-03800-NA, F740-04810-NA.)

Mitsubishi Electric Automation | Variable Frequency Drives 415


n VARIABLE FREQUENCY DRIVES
F700 General Specifications
Control System High carrier frequency PWM control (V/F control)/optimum excitation control/simple magnetic flux vector control
Output Frequency Range 0.5 to 400Hz

0.015Hz/0 to 60Hz (terminal 2, 4: 0 to 10V/12bit); 0.03Hz/0 to 60Hz (terminal 2, 4: 0 to 5V/11bit, 0 to 20mA/approx. 11bit,
Frequency Setting Analog Input
terminal 1: -10V to +10V/11bit); 0.06Hz/0 to 60Hz (terminal 1: 0 to ±5V/10bit)
Resolution
Control Specifications

Digital Input 0.01Hz

Frequency Analog Input Within ±0.2% of the max. output frequency (25°C ± 10°C)
Accuracy Digital Input Within 0.01% of the set output frequency
Voltage/Frequency Characteristics Base frequency can be set from 0 to 400Hz. Constant torque/variable torque pattern or adjustable 5 points V/F can be selected
Starting Torque 120% (3Hz) when set to simple magnetic flux vector control and slip compensation
Acceleration/Deceleration
0 to 3600s (acceleration and deceleration can be set individually), linear or S-pattern acceleration/deceleration mode can be selected.
Time Setting
DC Injection Brake Operation frequency (0 to 120Hz), operation time (0 to 10s), operation voltage (0 to 30%) variable
Stall Prevention Operation Level Operation current level can be set (0 to 150% adjustable), whether to use the function or not can be selected

Frequency Setting Analog Input Terminal 2, 4: 0 to 10V, 0 to 5V, 4 to 20mA can be selected. Terminal 1: -10 to +10V, -5 to 5V can be selected.
Signal Digital Input Four-digit BCD or 16-bit binary using the setting dial of the operation panel (when used with the option FR-A7AX)
Start Signal Available individually for forward and reverse rotation. Start signal automatic self-holding input (3-wire input) can be selected.
Select any twelve signals using Pr.178 to Pr.189 (input terminal function selection) from among multi-speed selection, second func-
tion selection, terminal 4 input selection, JOG operation selection, selection of automatic restart after instantaneous power failure,
external thermal relay input, HC connection (inverter operation enable signal), HC connection (instantaneous power failure detection),
Input Signals
PU operation/external interlock signal , PID control enable terminal, PU operation, external operation switchover, output stop, start
self-holding selection, forward rotation command, reverse rotation command, inverter reset, PTC thermistor input, PID forward reverse
operation switchover, PU-NET operation switchover, NET-external operation switchover, command source switchover.
Operation Specifications

Max. and min. frequency settings, frequency jump operation, external thermal relay input selection, polarity reversible operation, automatic
Operational Functions restart after instantaneous power failure operation, continuous operation at an instantaneous power failure, commercial power supply,
inverter switchover operation, forward/reverse rotation prevention, operation mode selection, PID control, computer link operation (RS-485).
Select any seven signals using Pr.190 to Pr.196 (output terminal function selection) from among inverter running, up-to-speed, instanta-
neous power failure/undervoltage, overload warning, output frequency detection, second output frequency detection, electronic thermal
relay function pre-alarm, PU operation mode, inverter operation ready, output current detection, zero current detection, PID lower limit,
PID upper limit, PID forward rotation reverse rotation output, commercial power supply-inverter switchover MC1, commercial power
Operating Status supply-inverter switchover MC2, commercial power supply-inverter switchover MC3, fan fault output, heatsink overheat pre-alarm, inverter
Output running start command on, deceleration at an instantaneous power failure, PID control activated, during retry, during PID output suspen-
Signals sion, life alarm, input MC stop signal, power savings average value update timing, current average monitor, alarm output 2, maintenance
timer alarm, remote output, minor failure output, alarm output. Open collector output (5 points), relay output
(2 points) and alarm code of the inverter can be output (4 bit) from the open collector.
When Used With The Select any seven signals using Pr. 313 to Pr. 319 (extension output terminal function selection) from among control circuit
FR-A7AY (Option) capacitor life, main circuit capacitor life, cooling fan life, inrush current limit circuit life.
Select from output frequency, motor current (steady or peak value), output voltage, frequency setting value, running speed, converter
output voltage (steady or peak value), electronic thermal relay function load factor, input power, output power, load meter, reference
Analog Output
voltage output, motor load factor, energy saving effect, PID set value, PID process value using Pr. 54 “CA terminal function selection
(analog current output)” and Pr. 158 “AM terminal function selection (analog output)”.
Output frequency, motor current (steady or peak value), output voltage, alarm indication, frequency setting, running speed, converter out-
put voltage (steady or peak value), electronic thermal load factor, input voltage, output voltage, road meter, cumulative energization time,
Operating Status actual operation time, motor load factor, cumulative energization power, power saving effect, cumulative saving power, PID set point, PID
Parameter process value, PID deviation value, inverter I/O terminal monitor, input terminal option monitor (*1), output terminal option monitor (*1),
Display

Unit (FR- option fitting status monitor (*2), terminal assignment status (*2)
DU07/
FR-PU04) Alarm definition is displayed when the protective function is activated, the output voltage/current/frequency/cumulative energization time
Alarm Definition
right before the protection function was activated and the past 8 alarm definitions are stored.
Interactive Guidance Operation guide/troubleshooting with a help function. (*2)
Overcurrent during acceleration, overcurrent during constant speed, overcurrent during deceleration, overvoltage during acceleration,
overvoltage during constant speed, overvoltage during deceleration, inverter protection thermal operation, heatsink overheat, instanta-
neous power failure occurrence, undervoltage, input phase failure, motor overload, output side earth (ground) fault overcurrent, output
phase failure, external thermal relay operation, PTC thermistor operation, option alarm, parameter error, PU disconnection, retry count
Protective/Warning Function
excess, CPU alarm, power supply short for operation panel, 24VDC power output short, output current detection value over, inrush resis-
tance overheat, communication alarm (inverter), analog input alarm, internal circuit alarm (15V power supply), fan fault, overcurrent stall
prevention, overvoltage stall prevention, electronic thermal prealarm, PU stop, maintenance timer alarm (*1), parameter write error, copy
operation error, operation panel lock.
Ambient Temperature -10°C to +50°C (non-freezing)
Environment

Ambient Humidity 90% RH or less (non-condensing)


Storage Temperature (*3) -20°C to +65°C
Atmosphere Indoors (without corrosive gas, flammable gas, oil mist, dust and dirt, etc.)
Altitude, Vibration Maximum 1000m above sea level, 5.9m/s2 or less (conforms to JIS C 0040)
Notes:
1. Can be displayed only on the operation panel (FR-DU07).
2. Can be displayed only on the parameter unit (FR-PU04/FR-PU07).
3. Temperature applicable for a short period in transit, etc.

416
F700 Series Terminal Connection Diagram

F700 Control Terminal Layout

A1 B1 C1 A2 B2 C2 10E 10 2 5 4

RL RM RH RT AU STOP MRS RES SD CA AM 1

SE RUN SU IPF OL FU SD SD STF STR JOG CS PC

Mitsubishi Electric Automation | Variable Frequency Drives 417


n VARIABLE FREQUENCY DRIVES
F700 Factory Supplied DC Link Chokes
Standard With VFD Dimensions inches (mm) Approx.
Weight
FR-F700 Series DC Link Model Number mH Amps Watt Loss Height Width Depth lb (kg)
FR-F740-01800-NA FR-HEL-H90K 0.3 191 130 13.4 (340) 5.9 (150) 7.5 (190) 20 (44)
FR-F740-02160-NA FR-HEL-H110K 0.246 233 130 13.4 (340) 5.9 (150) 7.7 (195) 22 (48)
FR-F740-02600-NA FR-HEL-H132K 0.204 281 140 15.9 (405) 6.9 (175) 7.9 (200) 26 (57)
FR-F740-03250-NA FR-HEL-H160K 0.171 335 140 15.9 (405) 6.9 (175) 8 (205) 28 (62)
FR-F740-03610-NA FR-HEL-H185K 0.148 389 170 15.9 (405) 6.9 (175) 9.4 (240) 29 (64)
FR-F740-04320-NA FR-HEL-H220K 0.124 462 230 15.9 (405) 6.9 (175) 9.4 (240) 30 (66)
FR-F740-04810-NA FR-HEL-H250K 0.109 524 240 17.3 (440) 7.5 (190) 9.8 (250) 35 (77)
FR-F740-05470-NA FR-HEL-H280K 0.098 585 270 17.3 (440) 7.5 (190) 10 (255) 38 (84)
FR-F740-06100-NA FR-HEL-H315K 0.087 658 300 19.5 (495) 8.3 (210) 9.8 (250) 42 (92)
FR-F740-06830-NA FR-HEL-H355K 0.077 742 360 19.5 (495) 8.3 (210) 9.8 (250) 46 (101)
FR-F740-07700-NA FR-HEL-H400K 0.069 836 360 19.7 (500) 8.7 (220) 9.8 (250) 50 (110)
FR-F740-08660-NA FR-HEL-H450K 0.061 940 450 19.7 (500) 8.7 (220) 10.6 (270) 57 (125)
FR-F740-09620-NA FR-HEL-H500K 0.055 1045 450 17.8 (455) 8.5 (215) 13.6 (345) 67 (1147)
FR-F740-10940-NA FR-HEL-H560K 0.049 1170 470 18.1 (460) 8.5 (215) 14.2 (360) 85 (187)
FR-F740-12120-NA FR-HEL-H630K 0.044 1317 500 18.1 (460) 8.5 (215) 14.2 (360) 95 (209)

F700 Frame Size


Dimensions inches (mm) Weight Without Reactor
Frame Size
Height Width Depth lbs (kg)
A 10.2 (260) 4.3 (110) 4.3 (110) 4.2 (1.9)
B 10.2 (260) 4.3 (110) 4.9 (125) 5 (2.3)
C 10.2 (260) 5.9 (150) 5.5 (140) 9.3 (4.2)
D 10.2 (260) 8.7 (220) 6.7 (170) 17.7 (8)
E 11.8 (300) 8.7 (220) 7.5 (190) 19.4 (8.8)
F 15.8 (400) 9.8 (250) 7.5 (190) 32.6 (14.8)
G 21.7 (550) 12.8 (325) 7.7 (195) 77.1 (35)
H 21.7 (550) 17.1 (435) 9.8 (250) 134.4 (61)
J 27.6 (700) 18.3 (465) 9.8 (250) 134.4 (61)
K 29.1 (740) 18.3 (465) 14.2 (360) 244.5 (111)
L 39.8 (1010) 19.6 (498) 15 (380) 378.9 (172)
M 39.8 (1010) 26.8 (680) 15 (380) 385 (175)
N 52.4 (1330) 31.1 (790) 17.3 (440) 572 (260)
P 62.2 (1580) 39.2 (995) 17.3 (440) 814 (370)

418
F700 Series Options Instruction Manuals
Stocked
Description Model Number
Item
FR-F700 Installation Manual - Contains instructions
Conduit Attachments for installer and parameter list. (Included with VFD, IB(NA)0600218 -
plus CD with all versions of VFD and option manuals.)
Drive Model Length Weight Stocked
Model Number FR-F700-NAPLC Function Programming Manual IB(NA)0600420 -
F720 (*1) F740 (*1) (in) (*4) (lbs) Item
FR-A7FN05 (*3) 01250 - 5.9 5 - FR-F700 Basic Manual - Contains wiring details, VFD
IB(NA)0600216 -
FR-A7FN06 (*3) 01540 00770 6.2 5 S layout drawings, alarm definitions and parameter list.
FR-A7FN07 (*3) 01870, 02330 00930, 01160 9 15 S FR-F700 Applied Manual - Contains wiring details,
FR-A7FN-10 (*2) - 01800 24 37 S VFD layout drawings, alarm definitions and complete IB(NA)0600217 -
parameter list with definitions and setting examples.
FR-A7FN-11 (*2) - 02160, 02600 24 41 S
03160, 03800, FR-PU07 Manual - Contains complete instruction
FR-A7FN-12 (*2) 03250, 03610 24 45 S IB(NA)0600240 -
04750 sets and screen definitions.
FR-A7FN-13 (*2) - 04320, 04810 26 50 S Manuals available for download at www.meau.com
05470, 06100,
FR-A7FN-14 (*2) - 26 64 S
06830
Notes: Parameter Units / Parameter Copy Units
1. For FR-F700s smaller than listed above, they are UL Type 1, and conduit attachment is standard.
2. Mounting hardware included for standard DC chokes which ship with VFD. Kits are powder coated
Parameter units are used for operator control, reading and
similar to VFD, charcoal gray. writing parameters, and drive monitoring. Parameter Copy
3. Kits are coated zinc clear. Units also read the drive parameter settings and copy them into
4. Width and depth of kit match the associated VFD.
non-volatile memory, and can write them into other drives.
Stocked
Model Number Description
External Heatsink Attachment Item
FR-CB201 Extension cable straight plugs on both ends - 1M S
Model Number Drive Model
Stocked Item FR-CB203 Extension cable straight plugs on both ends - 3M S
(*1) F720 F740
FR-CB205 Extension cable straight plugs on both ends - 5M S
FR-A7CN01 00105 to 00250 00023 to 00126 S
FR-DU07 Control Panel for F700 S
FR-A7CN02 00340, 00490 00170, 00250 S LCD Multi-lingual Parameter Copy Unit (English,
FR-A7CN03 00630 00310, 00380 S French, Spanish, German, Italian, Swedish, Finnish,
FR-A7CN04 00770 to 01250 00470, 00620 S FR-PU07 Japanese) for operator control, parameter read/write and S
monitoring. Stores settings in non-volatile memory.
FR-A7CN05 01540 - S Built-in parameter copy capability. (F/A700 based)
FR-A7CN06 - 00770 S FR-PU07-01 PU07 with hand/auto and enhanced display functions S
FR-A7CN07 01870, 02330 00930, 01160, 01800 S FR-ADP FR-DU07 panel mounting adapter S
FR-A7CN08 - 02160 - LCD Multi-lingual Parameter Copy Unit (English, French,
FR-A7CN09 - 02600 - FR-PU04 Spanish, German, Italian, Swedish, Finnish, Japanese) for S
operator control, parameter read/write and monitoring.
FR-A7CN10 03160, 03800, 04750 03250, 03610 -
SC-FRPC Serial Communication Cable S
Note: FR-PU07BB-L Battery powered PU07 S
1. Kits are coated zinc clear.
FR-RJ45-HUB4 Serial network hub - 2 stations -
FR-RJ45-HUB10 Serial network hub - 8 stations -
Option Cards FR-RJ45-TR Terminating resistor for FR-RJ45-HUB -

Model No. Stocked Item


Relay Output FR-A7AR S
Building Management Options
Function

12 Bit Digital Input FR-A7AX S


FR-A7N-ETH FR-A7N-XLT ETH-1000 XLTR-1000
Network Type / Model
Digital Output (*1,*2) (*1,*2) (*3,*4) (*3,*4)
FR-A7AY S BACnet/IP X - X -
Ext. Analog Output
EtherNet/IP X - X -
Communication

CC-Link FR-A7NC S
Communication

Modbus TCP X - X -
Gateway

DeviceNet FR-A7ND S PROFINET IO X - X -


BACnet MS/TP (*5) - X X X
LonWorks FR-A7NL S
Metasys N2 - X X X
Profibus DP FR-A7NP S Siemens FLN - X - -
Stocked Item S S - -
Notes:
For additional information, visit www.iccdesigns.com
F700 Demonstration Unit 1. Physically mounts within VFD and powered by VFD
2. FR-E7TR option recommended. (PU connector not available for use)
3. Communication to multiple VFD’s is possible
Model Number Description Stocked Item 4. Mounted and powered external to VFD
5. BACnet MS/TP is built in to F700. Gateway required for pre August 2010 production.
Includes F720 1HP, pre-wired digital
VFD-F700-DEMO-2 input switches, LED outputs, speed S
potentiometer and analog meter Software
Model Number Description Stocked Item
Includes 1/2HP motor with quick
VFD-MOTOR-DEMO S Programming and diagnostic
connection to VFD-F700-DEMO FR-CONFIGURATOR S
software

Mitsubishi Electric Automation | Variable Frequency Drives 419


n VARIABLE FREQUENCY DRIVES
Parameter Unit/Cable Reference List
A700 Extension cables
VFD Model E560 D700 E700 1 = Direct mount
F700 2 = FR-CB201, FR-CB203, FR-CB205 - Where 1, 3, 5 indicate length in meters
FR-PA02 1/2b - - - 3 = SC-FRPC
FR-PA02-02 1/2b - - - Notes:
FR-DU04 2a - 2a 2a 1. a = Will not mount directly on drive’s cover - cable required.
2. b = To remote mount on the enclosure panel, an extension cable and gender change
Parameter FR-PU04 2a 2a 2a 2a
adapter (FR-E5P for E500,
Unit FR-DU07 - 2a 2a c SD-54258-8811 for F700) are required.
FR-PU07 - 2a 2a 1 3. c = Included standard with VFD.

FR-PU07BB-L - - 2a 2a
FR-PA07 - 2a 2a 2a
Software FR-CONFIGURATOR 3 3 3 3

Dynamic Braking Options


Select the brake unit according to the motor capacity.
To obtain braking torque greater than 200%, use a larger inverter capacity.
Up to 10 FR-BU2 brake units can be connected in parallel for increased braking capacity.

%ED or Time at Short-Time Rating When Braking Torque is 100%


Stocked Brake Resistor Stocked Motor Capacity (HP)
Brake Unit Model No.
Item Model No. Item 1 2 3 5 7.5 10 15 20 25 30 40 50 60 75
FR-BU2-1.5K S BU-1500-TEIKOUKI - 30 s - - - - - - - - - - - - -
FR-BU2-3.7K S BU-3700-TEIKOUKI - - 30 s - - - - - - - - - - - -
FR-BU2-7.5K S BU-7.5K-TEIKOUKI - - - 30 s 30 s - - - - - - - - - -
230V
FR-BU2-15K S FR-BR-15K-UL S - - - - 80% 40% 15% 10% - - - - - -
FR-BU2-30K S FR-BR-30K-UL S - - - - - - 65% 30% 25% 15% 10% - - -
FR-BU2-55K - FR-BR-55K-UL - - - - - - - - - 90% 60% 30% 20% 15% 10%
FR-BU2-H7.5K S 2 x BU-3700-TEIKOUKI - - - 30 s 30 s - - - - - - - - - -
FR-BU2-H15K S FR-BR-H15K-UL S - - - - 80% 40% 15% 10% - - - - - -
460V
FR-BU2-H30K S FR-BR-H30K-UL S - - - - - - 65% 30% 25% 15% 10% - - -
FR-BU2-H55K S FR-BR-H55K-UL S - - - - - - - - 90% 60% 30% 20% 15% 10%

Stocked Brake Resistor Stocked Motor Capacity (HP)


Brake Unit Model No.
Item Model No. Item 100 125 150 200 250 300 350 400 450 500 600 700 800
FR-BU2-H75K S MT-BR5-H75K - 10% 5% - - - - - - - - - - -
2 x FR-BU2-H75K S 2 x MT-BR5-H75K - 40% 25% 15% 10% 5% - - - - - - - -
3 x FR-BU2-H75K S 3 x MT-BR5-H75K - 90% 60% 40% 20% 14% 10% 5% 5% - - - - -
4 x FR-BU2-H75K S 4 x MT-BR5-H75K - - 95% 70% 40% 25% 15% 13% 10% 5% 5% - - -
460V
5 x FR-BU2-H75K S 5 x MT-BR5-H75K - - - - 60% 40% 25% 20% 15% 12% 10% 5% 5% -
6 x FR-BU2-H75K S 6 x MT-BR5-H75K - - - - 90% 55% 40% 25% 25% 15% 14% 10% 5% 5%
7 x FR-BU2-H75K S 7 x MT-BR5-H75K - - - - - 80% 55% 40% 35% 20% 15% 13% 10% 5%
8 x FR-BU2-H75K S 8 x MT-BR5-H75K - - - - - - 70% 50% 45% 30% 25% 15% 13% 10%

420
Braking Torque (%) at Short-Time Rating of 30 Sec. for 5HP and Less
Braking Torque (%) at Short-Time Rating of 15 Sec. for 7.5HP and Larger

Stocked Brake Resistor Stocked Motor Capacity (HP)


Brake Unit Model No.
Item Model No. Item 1 2 3 5 7.5 10 15 20 25 30 40 50 60 75
FR-BU2-1.5K S BU-1500-TEIKOUKI - 100% 50% - - - - - - - - - - - -
FR-BU2-3.7K S BU-3700-TEIKOUKI - - 100% 50% 50% - - - - - - - - - -
FR-BU2-7.5K S BU-7.5K-TEIKOUKI - - - 100% 100% - - - - - - - - - -
230V
FR-BU2-15K S FR-BR-15K-UL S - - - - 280% 200% 120% 100% 80% 70% - - - -
FR-BU2-30K S FR-BR-30K-UL S - - - - - - 260% 180% 160% 130% 100% 80% 70% -
FR-BU2-55K - FR-BR-55K-UL - - - - - - - - - 300% 250% 180% 150% 120% 100%
FR-BU2-H15K S FR-BR-H15K-UL S - - - - 280% 200% 120% 100% 80% 70% - - - -
460V FR-BU2-H30K S FR-BR-H30K-UL S - - - - - - 260% 180% 160% 130% 100% 80% 70% -
FR-BU2-H55K S FR-BR-H55K-UL S - - - - - - - - 300% 250% 180% 150% 120% 100%

Stocked Brake Resistor Stocked Motor Capacity (HP)


Brake Unit Model No.
Item Model No. Item 100 125 150 200 250 300 350 400 450 500 600 700 800
FR-BU2-H75K S MT-BR5-H75K - 100% 80% 65% 50% 40% 30% 28% 26% 22% 20% - - -
2 x FR-BU2-H75K S 2 x MT-BR5-H75K - 200% 165% 135% 100% 80% 65% 55% 53% 44% 40% 33% 28% 25%
3 x FR-BU2-H75K S 3 x MT-BR5-H75K - 300% 250% 200% 150% 120% 100% 85% 80% 65% 60% 50% 43% 37%
4 x FR-BU2-H75K S 4 x MT-BR5-H75K - - 300% 270% 200% 160% 135% 115% 105% 85% 80% 65% 55% 50%
460V
5 x FR-BU2-H75K S 5 x MT-BR5-H75K - - - 300% 250% 200% 170% 140% 130% 110% 100% 83% 70% 62%
6 x FR-BU2-H75K S 6 x MT-BR5-H75K - - - - 300% 240% 200% 170% 160% 130% 120% 100% 85% 75%
7 x FR-BU2-H75K S 7 x MT-BR5-H75K - - - - - 280% 235% 200% 185% 155% 140% 115% 100% 85%
8 x FR-BU2-H75K S 8 x MT-BR5-H75K - - - - - - 270% 230% 210% 175% 160% 130% 110% 100%

Dynamic Braking Unit and Resistor Specifications

Stocked Brake Resistor Stocked Weight Continuous Permissible


Brake Unit Model No. Resistance (Ohms) Rated (Watts)
Item Model No. Item kg / lbs Power (Watts)

FR-BU2-1.5K S BU-1500-TEIKOUKI - - 50 300 100


FR-BU2-3.7K S BU-3700-TEIKOUKI - - 30 900 300
FR-BU2-7.5K S BU-7.5K-TEIKOUKI - - 20 1800 600
230V
FR-BU2-15K S FR-BR-15K-UL S 15 / 33 8 4000 990
FR-BU2-30K S FR-BR-30K-UL S 30 / 66 4 8000 1990
FR-BU2-55K - FR-BR-55K-UL - 70 / 154 2 16000 3910
FR-BU2-H7.5K S 2 x BU-3700-TEIKOUKI - - 60 1800 600
FR-BU2-H15K S FR-BR-H15K-UL S 15 / 33 32 4000 990
460V FR-BU2-H30K S FR-BR-H30K-UL S 30 / 66 16 8000 1990
FR-BU2-H55K S FR-BR-H55K-UL S 70 / 154 8 16000 3910
FR-BU2-H75K S MT-BR5-H75K - 70 / 154 6.5 30000 7500

Mitsubishi Electric Automation | Variable Frequency Drives 421


n VARIABLE FREQUENCY DRIVES
F700 Dynamic Braking Units and Resistors - UFS Series
• A more economical solution to regenerative braking applications
• Internal Form-C relay
• Adjustable DC bus brake turn-on voltage
• Configurable master / slave brake configuration. Allows connection of up to 5 brake units (1 master / 4 slaves)

240V Series
Motor Capacity
Braking HP 7.5 10 15 20 25 30 40 50 60 75
Torque kW 5.5 7.5 11 15 18.5 22 30 37 45 55
100% For Brake Unit UFS22J UFS40J 2 x UFS40J
15 Secs. Brake Resistor RUFC15J RUFC22J RUFC40J 2 x RUFC40J
Continuous Permissible Power (W) UFS22J - 1500W UFS40J - 2000W 2ea x UFS40J - 4000W
Electrical
Resistance (Overall) RUFC15J - 24ohms RUFC22J - 12ohms RUFC40J - 7.5ohms 2ea x RUFC40J - 3.75ohms
Data
Continuous Current (Amps) 7A 10A 14.6A 29.2A

460V Series
Motor Capacity
Braking HP 7.5 10 15 25 30 40 50 60 75
Torque kW 5.5 7.5 11 18.5 22 30 37 45 55
100% For Brake Unit UFS22 UFS40
15 Secs. Brake Resistor RUFC15/480 RUFC22/480 RUFC40/480
Continuous Permissible Power (W) UFS22 - 2000W UFS40 - 4000W
Electrical
Resistance (Overall) RUFC15/480 - 44ohms RUFC22/480 - 27ohms RUFC40/480 - 15ohms
Data
Continuous Current (Amps) 6A 7.7A 14.6

Motor Capacity
Braking HP 100 125 150 175 215 300 375
Torque kW 75 90 110 132 160 220 280
100% For Brake Unit UFS110 2 X UFS110
15 Secs. Brake Resistor RUFC110/480 2 X RUFC110/480
Continuous Permissible Power (W) UFS110 - 8000W 2 x UFS110 - 16000W
Electrical
Resistance (Overall) RUFC110/480 - 6.8ohms 2 x RUFC110/480 - 3.4ohms
Data
Continuous Current (Amps) 30.7A 61.4A

Dimensions
Approximate
Height Width Depth Stocked
Model Number Weight
Item
mm inches mm inches mm inches kg lbs
UFS20J S
250 9.8 175 6.9 2.5 5.5
UFS40J S
240V RUFC15J 240 9.5 100 3.9 2.8 6.2 S
RUFC22J 310 12.2 75 3 3.5 7.7 S
RUFC40J 365 14.4 4.3 9.5 S
UFS22 S
100 3.9 175 6.9 2.5 5.5
UFS40 250 9.8 S
UFS110 107 4.2 195 7.7 3.9 8.6 S
480V RUFC15/480 310 12.2 3.5 7.7 S
100 3.9 75 3
RUFC22/480 365 14.4 4.2 9.3 S
RUFC40/480 2 x 365 2 x 14.4 2 x 100 2 x 3.9 2 x 75 2x3 8.7 19.2 S
RUFC110/480 4 x 365 4 x 14.4 4 x 100 4 x 3.9 4 x 75 4x3 17.3 38.1 S

422
F700 VFD Efficiency Values
240VAC 3-Phase Input 480VAC 3-Phase Input
Rated Watts Efficiency Watts Efficiency Rated Watts Efficiency Watts Efficiency
Model Number Model Number
Watts Loss SLD SLD Loss LD LD Watts Loss SLD SLD Loss LD LD
FR-F720-00046-NA 750 70 91% 60 92% FR-F740-00023-NA 750 60 92% 50 93%
FR-F720-00077-NA 1500 110 93% 100 93% FR-F740-00038-NA 1500 80 95% 80 95%
FR-F720-00105-NA 2200 140 94% 130 94% FR-F740-00052-NA 2200 100 95% 90 96%
FR-F720-00167-NA 3700 210 94% 190 95% FR-F740-00083-NA 3700 160 96% 140 96%
FR-F720-00250-NA 5500 300 95% 260 95% FR-F740-00126-NA 5500 190 97% 180 97%
FR-F720-00340-NA 7500 370 95% 340 95% FR-F740-00170-NA 7500 240 97% 220 97%
FR-F720-00490-NA 11000 590 95% 530 95% FR-F740-00250-NA 11000 340 97% 310 97%
FR-F720-00630-NA 15000 660 96% 580 96% FR-F740-00310-NA 15000 390 97% 350 98%
FR-F720-00770-NA 18500 910 95% 810 96% FR-F740-00380-NA 18500 490 97% 440 98%
FR-F720-00930-NA 22000 1050 95% 940 96% FR-F740-00470-NA 22000 580 97% 520 98%
FR-F720-01250-NA 30000 1540 95% 1370 95% FR-F740-00620-NA 30000 810 97% 710 98%
FR-F720-01540-NA 37000 1490 96% 1320 96% FR-F740-00770-NA 37000 1000 97% 930 97%
FR-F720-01870-NA 45000 1680 96% 1490 97% FR-F740-00930-NA 45000 1170 97% 1030 98%
FR-F720-02330-NA 55000 2210 96% 1950 96% FR-F740-01160-NA 55000 1510 97% 1320 98%
FR-F720-03160-NA 75000 2825 96% 2500 96% FR-F740-01800-NA 75000 2700 96% 2250 97%
FR-F720-03800-NA 90000 3165 96% 2800 96% FR-F740-02160-NA 90000 3300 96% 2700 97%
FR-F720-04750-NA 110000 4070 96% 3600 96% FR-F740-02600-NA 110000 3960 96% 3300 97%
- - - - - - FR-F740-03250-NA 132000 4800 96% 3960 97%
- - - - - - FR-F740-03610-NA 160000 5550 97% 4800 97%
- - - - - - FR-F740-04320-NA 185000 6600 96% 5550 97%
- - - - - - FR-F740-04810-NA 220000 7500 97% 6600 97%
- - - - - - FR-F740-05470-NA 250000 8400 97% 7500 97%
- - - - - - FR-F740-06100-NA 280000 9450 97% 8400 97%
- - - - - - FR-F740-06830-NA 315000 10650 97% 9450 97%
- - - - - - FR-F740-07700-NA 355000 12000 97% 10650 97%
- - - - - - FR-F740-08660-NA 400000 13500 97% 12000 97%
- - - - - - FR-F740-09620-NA 450000 15000 97% 13500 97%
- - - - - - FR-F740-10940-NA 500000 16800 97% 15000 97%
- - - - - - FR-F740-12120-NA 560000 18900 97% 16800 97%
General Notes:
1. The amount of heat generated by the inverter is based on one inverter connected to one motor of the same capacity.
2. The amount of heat generated in the above table is the amount of heat generated when the inverter is operated at its rated current.
3. The amount of heat generated will decrease according to the motor load and usage (duty).
4. When using the external heat sink attachment watt loss decreases by 60%.

Mitsubishi Electric Automation | Variable Frequency Drives 423


n VARIABLE FREQUENCY DRIVES
A700 Series
Mitsubishi Electric’s RSV technology gives you class-leading power, control and flexibility.

• Wide speed range: 200:1 operating range is • Brake Transistor Circuit: Included in all sizes
possible - even when the drive is used ‘open loop’ up to 30 Hp
• PLC feature: A700 programmability provides true • Integral Radio Filter: Limits Radio Noise
intelligence inside the drive - a simple emissions to meet EU Directive - all sizes of drive
solution for complex applications • Speed control: with or without torque limit allows
• Easy gain tuning: Compensates automatically for 200:1 Speed range, driving or overhauling
changes in load inertia to ensure smooth and • Open Loop Torque Control: including torque at
consistent operation zero speed
• Fast response: Up to 300 radians / second speed • UL Listed for single-phase input
response means lightning fast reaction to sudden
load changes
• USB port: Allows simple connection to the new
FR-Configurator Software for quick and easy
commissioning Voltage
• Power down braking: Keeps the motor under
control even if the supply power is lost 240 3/4 – 200 Hp
• Remote I/O capability: All of the drive I/O can be
read or controlled over a network 480 3/4 – 800 Hp

600 1 – 650 Hp

Horsepower

A700 Ratings 240V Class


Output voltage: 3 phase 200-240V at 60Hz - Voltage Tolerance 170-264V at 60Hz
ND (50°C) HD (50°C) LD (50°C) SLD (40°C)
Regenerative
150% OL / 1 min 200% OL / 1 min 120% OL / 1 min 110% OL / 1 min
Frame Cooling Protective Braking Torque Stocked
200% OL / 3 sec 250% OL / 3 sec 150% OL / 3 sec 120% OL / 3 sec Model Number (*6)
Size Method Rating / Max Value Item
Hp (*1) FLA Hp (*1) FLA Hp (*1) FLA Hp (*1) FLA (Permissible Duty)
1/2 3 1/4 1.5 1 4.2 1 4.6 FR-A720-00030-NA A S
Self 150% torque /
1 5 1/2 3 2 6.5 2 7.1 FR-A720-00050-NA B S
Cooling 3% ED
2 8 1 5 3 9.6 3 10.5 FR-A720-00080-NA C S
3 11 2 8 5 15.2 5 16.7 FR-A720-00110-NA C NEMA 1 S
100% torque /
(*2)
5 17.5 3 11 7.5 24 7.5 25 FR-A720-00175-NA C Forced Air 3% ED S
7.5 24 5 17.5 10 31 10 34 FR-A720-00240-NA D Cooling 100% torque / S
10 33 7.5 24 15 45 15 49 FR-A720-00330-NA D 2% ED S
1/2 3 1/4 1.5 1 4.2 1 4.6 FR-A720-00030-N4 A (*5) -
Self 150% torque /
1 5 1/2 3 2 6.5 2 7.1 FR-A720-00050-N4 B (*5) -
Cooling 3% ED
2 8 1 5 3 9.6 3 10.5 FR-A720-00080-N4 C (*5) -
3 11 2 8 5 15.2 5 16.7 FR-A720-00110-N4 C (*5) 100% torque / -
5 17.5 3 11 7.5 24 7.5 25 FR-A720-00175-N4 C (*5) 3% ED -
UL Type
7.5 24 5 17.5 10 31 10 34 FR-A720-00240-N4 D (*5) 1 - Plenum 100% torque / -
10 33 7.5 24 15 45 15 49 FR-A720-00330-N4 D (*5) Rated 2% ED -
15 46 10 33 20 58 20 63 FR-A720-00460-NA E S
20 61 15 46 25 70 25 77 FR-A720-00610-NA F Forced Air 20% torque / S
Cooling continuous (brake
25 76 20 61 30 85 30 93 FR-A720-00760-NA F transistor included) S
30 90 25 76 40 114 40 125 FR-A720-00900-NA F S
40 115 30 90 50 140 50/60 154 FR-A720-01150-NA G S
50 145 40 115 60 170 60 187 FR-A720-01450-NA H 20% torque / S
IP00 (*3)
60 175 50 145 75 212 75 233 FR-A720-01750-NA H continuous S
75 215 60 175 100 288 100/125 316 FR-A720-02150-NA JA S

A700 Ratings 240V Class


Output voltage: 3 phase 200-240V at 60Hz - Voltage Tolerance 170-264V at 60Hz - DC Link Choke is included with the VFD
ND (50°C) HD (50°C) LD (50°C) SLD (40°C)
Regenerative
150% OL / 1 min 200% OL / 1 min 120% OL / 1 min 110% OL / 1 min Model Number Frame Cooling Protective Braking Torque
Stocked Item
200% OL / 3 sec 250% OL / 3 sec 150% OL / 3 sec 120% OL / 3 sec (*6) Size Method Rating / Max Value
(Permissible Duty)
Hp FLA Hp FLA Hp FLA Hp FLA
100 288 75 215 125 346 150 380 FR-A720-02880-NA K Forced Air 10% torque / -
IP00 (*3)
125 346 100 288 150 432 200 475 FR-A720-03460-NA K Cooling continuous -
Notes: See next page.

424
A700 Ratings 480V Class
Output voltage: 3 phase 380-480V at 60Hz - Voltage Tolerance 323-528V at 60Hz.
ND (50°C) HD (50°C) LD (50°C) SLD (40°C) Regenerative
150% OL / 1 min 200% OL / 1 min 120% OL / 1 min 110% OL / 1 min Braking Torque
Frame Cooling Protective
Model Number (*6) / Max Value Stocked Item
200% OL / 3 sec 250% OL / 3 sec 150% OL / 3 sec 120% OL / 3 sec Size Method Rating
(Permissible
Hp (*1) FLA Hp (*1) FLA Hp (*1) FLA Hp (*1) FLA Duty)

1/2 1.5 1/4 0.8 1 2.1 1 2.3 FR-A740-00015-NA C S


Self
1 2.5 1/2 1.5 2 3.5 2 3.8 FR-A740-00025-NA C S
Cooling
2 4 1 2.5 3 4.8 3 5.2 FR-A740-00040-NA C S
NEMA 1 100% torque /
3 6 2 4 5 7.6 5 8.3 FR-A740-00060-NA C S
(*2) 2% ED
5 9 3 6 7.5 11.5 7.5 12.6 FR-A740-00090-NA C Forced Air S
7.5 12 5 9 10 16 10 17 FR-A740-00120-NA D Cooling S
10 17 7.5 12 15 23 15 25 FR-A740-00170-NA D S
1/2 1.5 1/4 0.8 1 2.1 1 2.3 FR-A740-00015-N4 C (*5) -
Self
1 2.5 1/2 1.5 2 3.5 2 3.8 FR-A740-00025-N4 C (*5) -
Cooling
2 4 1 25 3 4.8 3 5.2 FR-A740-00040-N4 C (*5) -
100% torque /
3 6 2 4 5 7.6 5 8.3 FR-A740-00060-N4 C (*5) -
2% ED
5 9 3 6 7.5 11.5 7.5 12.6 FR-A740-00090-N4 C (*5) -
UL Type 1
7.5 12 5 9 10 16 10 17 FR-A740-00120-N4 D (*5) - Plenum -
Rated
10 17 7.5 12 15 23 15 25 FR-A740-00170-N4 D (*5) -
15 23 10 17 20 29 20 31 FR-A740-00230-NA E S
20% torque /
20 31 15 23 25 35 25 38 FR-A740-00310-NA E Forced Air continuous S
25 38 20 31 30 43 30 47 FR-A740-00380-NA F Cooling (brake transis- S
tor included)
30 44 25 38 40 57 40 62 FR-A740-00440-NA F S
40 57 30 44 50 70 50/60 77 FR-A740-00570-NA G S
50 71 40 57 60 85 60 93 FR-A740-00710-NA H 20% torque / S
IP00 (*4)
60 86 50 71 75 106 75 116 FR-A740-00860-NA H continuous S
75 110 60 86 100 144 100/150 180 FR-A740-01100-NA H S
Notes: See below.

A700 Ratings 480V Class


Output voltage: 3 phase 380-480V at 60Hz - Voltage Tolerance 323-528V at 60Hz - DC Link Choke is included with the VFD.
ND (50°C) HD (50°C) LD (50°C) SLD (40°C)
Regenerative
150% OL / 1 min 200% OL / 1 min 120% OL / 1 min 110% OL / 1 min Braking Torque
Frame Cooling Protective
Model Number (*6) / Max Value Stocked Item
200% OL / 3 sec 250% OL / 3 sec 150% OL / 3 sec 120% OL / 3 sec Size Method Rating
(Permissible
Duty)
Hp (*1) FLA Hp (*1) FLA Hp (*1) FLA Hp (*1) FLA
100 144 75 110 150 180 150 216 FR-A740-01440-NA J S
150 180 100 144 150 216 200 260 FR-A740-01800-NA J S
150 216 150 180 200 260 250 325 FR-A740-02160-NA K S
200 260 150 216 250 325 300 361 FR-A740-02600-NA K S
250 325 200 260 300 361 350 432 FR-A740-03250-NA L IP00 (*4) S
300 361 250 325 350 432 400 481 FR-A740-03610-NA L S
350 432 300 361 400 481 450 547 FR-A740-04320-NA M Forced Air 10% torque / S
400 481 350 432 450 547 500 610 FR-A740-04810-NA M Cooling continuous S
450 547 400 481 500 610 550 683 FR-A740-05470-NA M S
500 610 450 547 550 683 650 770 FR-A740-06100-NA N -
550 683 500 610 650 770 700 866 FR-A740-06830-NA N -
650 770 550 683 700 866 800 962 FR-A740-07700-NA P IP00 -
700 866 650 770 800 962 900 1094 FR-A740-08660-NA P -
800 962 700 866 900 1094 1000 1212 FR-A740-09620-NA P -

Notes:
1. Motor ratings shown are intended as guidelines only - based on 4 pole standard inductions motors.
2. UL Type 1 version drives are available - replace “-NA” suffix with “-N4”.
3. Conduit adapter option required for types 01150 - 03460.
4. Conduit adapter option required for types 00570 - 05470.
5. Depth is slightly extended to meet UL Type 1 requirements.
6. For single phase input, derate output current by 40% (Models up to FR-A720-02880-NA and FR-A740-03610-NA)

Mitsubishi Electric Automation | Variable Frequency Drives 425


n VARIABLE FREQUENCY DRIVES
A700 Ratings 600V Class
Output voltage: 3 phase 525-600V at 60Hz - Voltage Tolerance 472-660V at 60Hz
ND (40°C) HD (40°C) LD (40°C) SLD (40°C) (30°C
200% OL / 1 min for 00040 or less) Regenerative
150% OL / 1 min 120% OL / 1 min Braking Torque
250% OL / 3 sec. 110% OL / 1 min Frame Cooling Protective DC Link Stocked
Model Number / Max Value
280% OL / 0.5 Size Method Rating Reactor Item
200% OL / 3 sec. 150% OL / 3 sec. 120% OL / 3 sec. (Permissible
sec. Duty)
HP (*1) FLA HP (*1) FLA HP (*1) FLA HP (*1) FLA
Self cool-
1 1.7 1/2 1.0 1 1/2 2.5 2 2.7 FR-A760-00017-NA -
ing UL Type 1 100% torque /
3 4.0 2 2.7 3 5.6 5 6.1 FR-A760-00040-NA C (*3) 2% ED S
5 6.1 3 4.0 5 8.2 7 1/2 9.0 FR-A760-00061-NA S
10 12 7 1/2 9.0 10 16 15 17 FR-A760-00120-NA D 20% torque / Option S
Forced air continuous
20 22 10 16 25 27 30 32 FR-A760-00220-NA E UL Type 1 S
cooling (brake transistor
30 33 20 24 40 41 40 45 FR-A760-00330-NA F included) S
50 55 40 41 60 62 60 68 FR-A760-00550-NA 20% torque / S
H IP00 (*4)
75 84 60 63 100 99 (*2) 100 108 (*2) FR-A760-00840-NA continuous S

ND (50°C) HD (40°C) LD (50°C)


SLD (40°C)
200% OL / 1 min Regenerative
150% OL / 1 min 120% OL / 1 min Braking Torque
250% OL / 3 sec. 110% OL / 1 min Frame Cooling Protective DC Link Stocked
Model Number / Max Value
Size Method Rating Reactor Item
200% OL / 3 sec. 280% OL / 0.5 sec. 150% OL / 3 sec. 120% OL / 3 sec. (Permissible
HP Duty)
FLA HP (*1) FLA HP (*1) FLA HP (*1) FLA
(*1)
100 104 75 84 125 131 150 144 FR-A760-01040-NA S
125 131 100 104 150 152 150 167 FR-A760-01310-NA J S
150 152 125 131 200 221 250 243 FR-A760-01520-NA S
IP00 (*4)
200 221 150 152 250 255 300 289 FR-A760-02210-NA S
L Forced air 20% torque /
250 255 200 202 300 304 350 336 FR-A760-02550-NA Standard -
cooling continuous
300 304 250 255 400 402 450 442 FR-A760-03040-NA M S
400 402 300 304 500 496 550 545 FR-A760-04020-NA N -
500 496 400 402 600 589 650 647 FR-A760-04960-NA IP00 S
P
650 663 600 589 750 773 850 850 FR-A760-06630-NA -
Notes:
1. Motor ratings shown are intended as guidelines only - based on 4 pole standard induction motors.
2. To utilize these ratings, DC Link reactor is required.
3. These models supplied with an externally connected brake resistor. When the external brake resistor is used, protective rating is open type (NEMA1).
4. Conduit adapter option required for types 00550-03040.

426
A700 Terminal Connection Diagram

A700 Control Terminal Layout

A1 B1 C1 A2 B2 C2 10E 10 2 5 4

RL RM RH RT AU STOP MRS RES SD FM AM 1

SE RUN SU IPF OL FU SD SD STF STR JOG CS PC

Mitsubishi Electric Automation | Variable Frequency Drives 427


n VARIABLE FREQUENCY DRIVES
A700 General Specifications
Soft-PWM control/high carrier frequency PWM control (selectable from among V/F control, advanced magnetic flux vector control and
Control Method real sensorless vector control) / vector control (when used with option FR-A7AP) (*1)
Output Frequency Range 0.2 to 400Hz
Frequency 0.015Hz/0 to 60Hz (terminal 2, 4: 0 to 10V/12 bit); 0.03Hz/0 to 60Hz (terminal 2, 4: 0 to 5V/11 bit, 0 to 20mA/about 11 bit, terminal 1: 0 to
Analog Input
Setting ±10V/12 bit) 0.06Hz/0 to 60Hz (terminal 1: 0 to ±5V/11 bit)
Resolution Digital Input 0.01Hz
Frequency Analog Input Within ±0.2% of the max. output frequency (25°C ±10°C)
Accuracy Digital Input Within 0.01% of the set output frequency
Voltage / Frequency Base frequency can be set from 0 to 400Hz Constant torque/variable torque pattern or adjustable 5 points V/F can be selected
Characteristics
Starting Torque 200% 0.3Hz (up to frame size C), 150% 0.3Hz (Frame Size D and above) (under real sensorless vector control or vector control)
Torque Boost Manual torque boost
Acceleration / Deceleration 0 to 3600s (acceleration and deceleration can be set individually), linear or S-pattern acceleration/deceleration mode, backlash mea-
Time Setting sures acceleration/deceleration can be selected.
DC Injection Brake Operation frequency (0 to 120Hz), operation time (0 to 10s), operation voltage (0 to 30%) variable
Stall Prevention Operation Operation current level can be set (0 to 220% adjustable), whether to use the function or not can be selected
Level
Torque Limit Level Torque limit value can be set (0 to 400% variable)
Frequency Analog Input Terminal 2: 4: 0 to 10V, 0 to 5V, 4 to 20mA can be selected • Terminal 1:-10 to +10V, -5 to +5V can be selected
Setting
Signal Digital Input Input using the setting dial of the operation panel or parameter unit. Four-digit BCD or 16 bit binary (when used with option FR-A7AX)
Start Signal
Forward and reverse rotation or start signal automatic self-holding input (3-wire input) can be selected.
Select any twelve signals using Pr. 178 to Pr. 189 (input terminal function selection) from among multi speed selection, remote setting, stop-on-contact,
Operation Specifications

second function selection, third function selection, terminal 4 input selection, JOG operation selection, selection of automatic restart after instantaneous
power failure, flying start, external thermal relay input, inverter operation enable signal (FR-HC/FR-CV connection), FR-HC connection (instantaneous
power failure detection), PU operation/external inter lock signal, external DC injection brake operation start, PID control enable terminal, brake opening
Input Signal completion signal, PU operation/external operation switchover, load pattern selection forward rotation reverse rotation boost, V/F switching, load torque
high-speed frequency, S-pattern acceleration/deceleration C switchover, pre-excitation, output stop, start self-holding selection, control mode changing,
torque limit selection, start-time tuning start external input, torque bias selection 1, 2 (*1), P/PI control switchover, forward rotation command, reverse
rotation command, inverter reset, PTC thermistor input, PID forward reverse operation switchover, PU-NET operation switchover, NET-external operation
switchover, and command source switchover, conditional position pulse train sign (*1), conditional position droop pulse clear (*1).
Pulse Train Input 100kpps
Maximum/minimum frequency setting, frequency jump operation, external thermal relay input selection, polarity reversible operation, automatic
restart after instantaneous power failure operation, commercial power supply-inverter switchover operation, forward/reverse rotation prevention,
remote setting, brake sequence, second function, third function, multi-speed operation, original operation continuation at instantaneous power
Operational Functions failure, stop-on-contact control, load torque high speed frequency control, droop control, regeneration avoidance, slip compensation, operation
mode selection, offline auto tuning function, online auto tuning function, PID control, computer link operation (RS-485), motor end orientation
(*1), machine end orientation (*1), pre-excitation, notch filter, machine analyzer (*1), easy gain tuning, speed feed forward, and torque bias (*1)
Select any signals using Pr. 190 to Pr. 196 (output terminal function selection) from among inverter running, up-to-frequency, instantaneous
power failure/undervoltage, overload warning, output frequency (speed) detection, second output frequency (speed) detection, third output
frequency (speed) detection, regenerative brake prealarm, electronic thermal relay function pre-alarm, PU operation mode, inverter operation
ready, output current detection, zero current detection, PID lower limit, PID upper limit, PID forward rotation reverse rotation output, commercial
power supply-inverter switchover MC1, commercial power supply-inverter switchover MC2, commercial power supply-inverter switchover MC3,
Operating orientation completion (*1), brake opening request, fan fault output, heatsink overheat pre-alarm , inverter running/start command on, deceleration
Status
Output at an instantaneous power failure, PID control activated, during retry, PID output interruption, life alarm, alarm output 1, 2, 3 (power-off signal),
Signals power savings average value update timing, current average monitor, maintenance timer alarm, remote output, forward rotation output (*1),
reverse rotation output (*1), low speed output, torque detection, regenerative status output (*1), start-time tuning completion, in-position
completion (*1), minor failure output and alarm output. Open collector output (5 points), relay output (2 points) and alarm code of the inverter
can be output (4 bit) from the open collector.
Using FR-A7AY, In addition to the above, select any signals using Pr. 313 to Pr. 319 (extension output terminal function selection) from among control circuit
FR-A7AR capacitor life, main circuit capacitor life, cooling fan life, inrush current limit circuit life (only positive logic can be set for extension terminals of the
(optional) FR-A7AR).
Pulse Train Input 500kpps
Select any signals using Pr. 54 FM terminal function selection (pulse train output) and Pr. 158 AM terminal function selection (analog output) from
among output frequency, motor current (steady or peak value), output voltage, frequency setting, operation speed, motor torque, converter output
Pulse / Analog Output voltage (steady or peak value), electronic thermal relay function load factor, input power, output power, load meter, motor excitation current,
reference voltage output, motor load factor, power saving effect, regenerative brake duty, PID set point, PID measured value, motor output, torque
command, torque current command, and torque monitor.
Output frequency, motor current (steady or peak value), output voltage, frequency setting, running speed,motor torque, overload, converter
output voltage (steady or peak value), electronic thermal relay function load factor, input power, output power, load meter, motor excitation
Operating current, cumulative energization time, actual operation time, motor load factor, cumulative power, energy saving effect, cumulative saving power,
PU (FR- Status regenerative brake duty, PID set point, PID measured value, PID deviation, inverter I/O terminal monitor, input terminal option monitor (*2), output
Indication

DU07 / terminal option monitor (*2), option fitting status (*3), terminal assignment status (*3), torque command, torque current command, feed back
FR-PU07 / pulse (*1), motor output
FR-PU04) Alarm Alarm definition is displayed when the protective function is activated, the output voltage/current/frequency/cumulative energization time right
Definition before the protection function was activated and past 8 alarm definitions are stored.
Interactive Operation guide/trouble shooting with a help function (*3)
Guidance
Overcurrent during acceleration, overcurrent during constant speed, overcurrent during deceleration, overvoltage during acceleration, overvoltage
during constant speed, overvoltage during deceleration, inverter protection thermal operation, motor protection thermal operation, heatsink
overheat, instantaneous power failure occurrence, undervoltage, input phase failure, motor overload, output side earth (ground) fault overcurrent,
output short circuit, main circuit element overheat, output phase failure, external thermal relay operation, PTC thermistor operation, option alarm,
parameter error, PU disconnection, retry count excess, CPU alarm, operation panel power supply short circuit, 24VDC power output short circuit,
Protective / Warning Function output current detection value excess, inrush current limit circuit alarm, communication alarm (inverter), USB error, opposite rotation deceleration
error, analog input error, fan fault, overcurrent stall prevention, overvoltage stall prevention, regenerative brake prealarm, electronic thermal relay
function prealarm, PU stop, maintenance timer alarm (*2), brake transistor alarm, parameter write error, copy operation error, operation panel
lock, parameter copy alarm, speed limit indication, encoder no-signal (*1), speed deviation large (*1), overspeed (*1), position error large (*1),
encoder phase error (*1)
Ambient Temperature -10°C to +50°C (non-freezing)
Environment

Ambient Humidity 90%RH maximum (non-condensing)


Storage Temperature (*4) -20°C to +65°C
Atmosphere Indoors (without corrosive gas, flammable gas, oil mist, dust and dirt etc.)
Altitude / Vibration Maximum 1000m above sea level, 0.6 G or less (conforms to JIS C 60068-2-6) (*5)
Notes:
1. Available only when the option (FR-A7AP) is mounted
2. Can be displayed only on the operation panel (FR-DU07).
3. Can be displayed only on the parameter unit (FR-PU07/FR-PU04).
4. Temperature applicable for a short period in transit, etc.
5. 2.9m/s2 or less for the FR-A740-03250 or more.

428
A700 Options Instruction Manuals
Description Model Number
FR-A700 Installation Manual - Contains instructions for
Function / Options installer and parameter list. (Included with VFD, plus CD with IB(NA)0600254
all versions of VFD and option manuals.)
Model No. Stocked Item FR-A700 Basic Manual - Contains wiring details, VFD
IB(NA)0600225
120VAC Control Input FR-A7AC S layout drawings, alarm definitions and parameter list.

Analog I/O FR-A7AN S FR-A700 Applied Manual - Contains wiring details, VFD layout
drawings, alarm definitions and complete parameter list with IB(NA)0600255
Encoder Feedback FR-A7AP S
definitions and setting examples.
Encoder Pulse Dividing Output FR-A7AL S
FR-A700 PLC Programming Manual - Contains
Relay Output FR-A7AR S IB(NA)0600262
Function

complete instruction sets for PLC feature.


12 Bit Digital Input FR-A7AX S
FR-PU07 Manual - Contains complete instruction sets
Digital Output IB(NA)0600240
FR-A7AY S and screen definitions.
Ext. Analog Output Manuals available for download at www.meau.com
BiPolar Analog Output
High Res Analog Input FR-A7AZ -
Building Management Options
Motor Thermistor
FR-A7N-ETH FR-A7N-XLT ETH-1000 XLTR-1000
CC-Link FR-A7NC S Network Type / Model
(*1,*2) (*1,*2) (*3,*4) (*3,*4)
ControlNET FR-A7NCN S BACnet/IP X - X -
Communication

DeviceNet FR-A7ND S EtherNet/IP X - X -

Communication
Modbus TCP X - X -

Gateway
EtherNet/IP FR-A7NE S
PROFINET IO X - X -
LonWorks FR-A7NL S
BACnet MS/TP (*5) - X X X
Profibus DP FR-A7NP S
Metasys N2 - X X X
SSCNET III FR-A7NS S Siemens FLN - X - -
Stocked Item S S - -
Notes:
For additional information, visit www.iccdesigns.com
External Heatsink Attachment 1. Physically mounts within VFD and powered by VFD
2. FR-E7TR option recommended. (PU connector not available for use)
Drive Model Model Stocked 3. Communication to multiple VFD’s is possible
A720 A740 A760 Number Item 4. Mounted and powered external to VFD
5. BACnet MS/TP is built in to F700. Gateway required for pre August 2010 production.
00017, 00040,
00080 to 00175 00025 to 00090 FR-A7CN01 S
00061
00240, 00330 00120, 00170 00120 FR-A7CN02 S
00460 00230, 00310 00220 FR-A7CN03 S Conduit Attachments
00610 to 00900 00380, 00440 00330 FR-A7CN04 S Drive Model Length
Weight Stkd.
01150 - FR-A7CN05 S Model Number A720 A740 A760 (in)
(lbs) Item
00570 - FR-A7CN06 S (*1, *2) (*1, *2) (*1, *2) (*5)
01450, 01750 00710 to 01100 00550, 00840 FR-A7CN07 S FR-A7FN05 (*4) 00900 - - 5.9 5 -
01040, 01310, FR-A7FN06 (*4) 01150 00570 - 6.2 5 S
01440 FR-A7CN08 -
01520
01450, 00710 to 00550,
01800 - FR-A7CN09 - FR-A7FN07 (*4) 9 15 S
01750 01100 00840
03160, 03800,
02160, 02600 - FR-A7CN10 - 01440, 01040 to
04750 FR-A7FN-11 (*3) - 24 41 S
01800 01520
02150 - FR-A7CN11 -
02880, 02160,
FR-A7FN-12 (*3) - 24 45 S
03460 02600
03250, 02210,
Software FR-A7FN-13 (*3) -
03610 02550
26 50 S
Model Number Description Stocked Item 04320 to
FR-A7FN-14 (*3) - 03040 26 64 S
FR-CONFIGURATOR Programming and diagnostic software S 05470
Notes:
1. FR-A720-00460 to 00760 & FR-A740-00230 to 00440 are UL Type 1: the conduit adapter is
included as standard.
2. FR-A700 smaller than listed above, the UL Type 1 version (conduit adapter standard) is a
A700 Demonstration Unit special type: Change from suffix -NA to -N4.
3. Mounting hardware included for standard DC chokes which ship with VFD. Kits are powder
Model Stocked coated similar to VFD charcoal gray.
Description 4. Kits are coated zinc clear.
Number Item
5. Width and depth of kit match the asscociated VFD
VFD-A700- Includes A720 1/2HP, pre-wired digital input switches, LED out-
S
DEMO puts, two potentiometers, analog meter and encoder option
VFD-MOTOR- Includes 1/2HP motor and encoder with quick connections to
S
ENC-DEMO VFD-A700-DEMO

Mitsubishi Electric Automation | Variable Frequency Drives 429


n VARIABLE FREQUENCY DRIVES
Factory Supplied DC Link Chokes
Standard With VFD Dimensions inches (mm)
Approx Weight lb (kg)
Drive Model DC Link Model No. mH Amps Height Width Depth
FR-A740-01440-NA FR-HEL-H110K 0.246 233 13.4 (340) 5.9 (150) 7.7 (195) 22 (48)
FR-A740-01880-NA FR-HEL-H132K 0.204 281 15.9 (405) 6.9 (175) 7.9 (200) 26 (57)
FR-A740-02160-NA FR-HEL-H160K 0.171 335 15.9 (405) 6.9 (175) 8 (205) 28 (62)
FR-A740-02600-NA FR-HEL-H185K 0.148 389 15.9 (405) 6.9 (175) 9.4 (240) 29 (64)
FR-A740-03250-NA FR-HEL-H220K 0.124 462 15.9 (405) 6.9 (175) 9.4 (240) 30 (66)
FR-A740-03610-NA FR-HEL-H250K 0.109 524 17.3 (440) 7.5 (190) 9.8 (250) 35 (77)
FR-A740-04320-NA FR-HEL-H280K 0.098 585 17.3 (440) 7.5 (190) 10 (255) 38 (84)
FR-A740-04810-NA FR-HEL-H315K 0.087 658 19.5 (495) 8.3 (210) 9.8 (250) 42 (92)
FR-A740-05470-NA FR-HEL-H355K 0.077 742 19.5 (495) 8.3 (210) 9.8 (250) 46 (101)
FR-A740-06100-NA FR-HEL-H400K 0.069 836 19.7 (500) 8.7 (220) 9.8 (250) 50 (110)
FR-A740-06830-NA FR-HEL-H450K 0.061 940 19.7 (500) 8.7 (220) 10.6 (270) 57 (125)
FR-A740-07700-NA FR-HEL-H500K 0.055 1045 17.8 (455) 8.5 (215) 13.6 (345) 67 (147)
FR-A740-08660-NA FR-HEL-H560K 0.049 1170 18.1 (460) 8.5 (215) 14.2 (360) 85 (187)
FR-A740-09620-NA FR-HEL-H630K 0.044 1317 18.1 (460) 8.5 (215) 14.2 (360) 95 (209)

A700 Frame Size


Drive Height x Width x Depth
Frame Weight Without Reactor
Dimensions inches (mm)
Size lbs (kg)
Height Width Depth
A 10.2 (260) 4.3 (110) 4.3 (110) 4.2 (1.9)
B 10.2 (260) 4.3 (110) 4.9 (125) 5 (2.3)
C 10.2 (260) 5.9 (150) 5.5 (140) 9.3 (4.2)
D 10.2 (260) 8.7 (220) 6.7 (170) 17.7 (8)
E 11.8 (300) 8.7 (220) 7.5 (190) 19.4 (8.8)
F 15.8 (400) 9.8 (250) 7.5 (190) 32.6 (14.8)
G 21.7 (550) 12.8 (325) 7.7 (195) 77.1 (35)
H 21.7 (550) 17.1 (435) 9.8 (250) 134.4 (61)
JA 27.6 (700) 18.3 (465) 9.8 (250) 134.4 (61)
J 24.4 (620) 18.3 (465) 11.8 (300) 176.2 (80)
K 29.1 (740) 18.3 (465) 14.2 (360) 244.5 (111)
L 39.8 (1010) 19.6 (498) 15 (380) 378.9 (172)
M 39.8 (1010) 26.8 (680) 15 (380) 385 (175)
N 52.4 (1330) 31.1 (790) 17.3 (440) 572 (260)
P 62.2 (1580) 39.2 (995) 17.3 (440) 814 (370)

Parameter Units / Parameter Copy Units


Parameter units are used for operator control, reading and writing parameters, and
drive monitoring. Parameter Copy Units also read the drive parameter settings and
copy them into non-volatile memory, and can write them into other drives.
Model Number Description Stocked Item
FR-CB201 Extension cable straight plugs on both ends - 1M S
FR-CB203 Extension cable straight plugs on both ends - 3M S
FR-CB205 Extension cable straight plugs on both ends - 5M S
FR-DU07 Control Panel for A700 S
LCD Multi-lingual Parameter Copy Unit (English, French, Spanish,
German, Italian, Swedish, Finnish, Japanese) for operator control,
FR-PU07 S
parameter read/write and monitoring. Stores settings in non-volatile
memory. Built-in parameter copy capability. (F/A700 based)
FR-ADP FR-DU07 panel mounting adapter S
LCD Multi-lingual Parameter Copy Unit (English, French, Spanish,
FR-PU04 German, Italian, Swedish, Finnish, Japanese) for operator control, S
parameter read/write and monitoring
SC-FRPC Serial communication cable S
FR-PU07BB-L Battery powered PU07 S
FR-RJ45-HUB4 Serial network hub - 2 stations -
FR-RJ45-HUB10 Serial network hub - 8 stations -
FR-RJ45-TR Terminating resistor For FR-RJ45-HUB -

430
A700 Dynamic Braking
All Mitsubishi Electric VFD’s have some inherent braking capability. During controlled deceleration, motor regenerative losses are
dissipated in the motor, wire, and VFD circuitry. The built-in DC injection braking allows for low speed braking and stopping.
When the above capabilities are inadequate for an application, it is necessary to add a power transistor brake unit and resistor unit in
series across the DC bus.
Motor regeneration causes the DC bus voltage to increase, and when the voltage exceeds a specified threshold, the transistor turns on to
pass current through the resistor. Motor kinetic energy is converted to heat energy. VFD overcurrent and overvoltage protective circuits are
active at all times, and will fault-trip the VFD if the brake size is inadequate.
Two main factors must be considered when sizing the brake, the effective duty cycle (%ED) and the short time duty rating. The
effective duty cycle is increased when an external resistor is added. It is preferable to profile the effective duty cycle of the units of time.
With this information, the short time duty is known and the %ED can be calculated, as shown in the below example.
%ED = Braking time / total time for complete operating cycle x 100

Example: Complete cycle is:


5 sec: Acceleration time to reach set speed
60 sec: Run time at set speed
3 sec: Deceleration time to come to a complete stop
12 sec: Time period motor remains stopped

%ED = 3 / (5 + 60 + 3 + 12) x 100 = 3.6%


The tables shown assume 100% brake torque, when brake torque is represented by its percentage to the rated torque of the applied motor.
Torque (kg.m) = 974 x Power (kW) / Speed (rpm).

240VAC Dynamic Braking Resistor at 100% Braking Torque


Continuous Drive Model
Resistor Kit Model Weight kg Resistance
Permissible Motor (Hp) Stocked Item
Number (lbs) (Ohms) A720 % ED
Power (W)
FR-ABR-0.4K 0.2 (0.5) 200 60 1/2 00030 10% S
FR-ABR-0.75K 0.4 (0.9) 100 80 1 00050 10% S
00080 &
FR-ABR-2.2K 0.5 (1.1) 60 120 2 and 3 10% S
00110
FR-ABR-3.7K 0.8 (1.8) 40 155 5 00175 10% S
FR-ABR-5.5K 1.3 (2.9) 25 185 7 1/2 00240 10% S
FR-ABR-7.5K 2.2 (4.9) 20 340 10 00330 10% S
FR-ABR-11K 3.4 (7.5) 13 560 15 00460 6% S
FR-ABR-15K
2.4 (5.3) x 2 9 (18 / 2) 805 20 00610 6% S
(2 resistors in parallel)
FR-ABR-22K 25 00760 6%
3.3 (6.6) x 2 6.5 (13 / 2) 1120 S
(2 resistors in parallel) 30 00900 6%

480VAC Dynamic Braking Resistor at 100% Braking Torque


Continuous Drive Model
Resistor Kit Model Resistance
Weight Permissible Motor (Hp) Stocked Item
Number (Ohms) A740 % ED
Power (W)
FR-ABR-H0.4K 0.2 (0.5) 1200 45 1/2 00015 10% S
FR-ABR-H0.75K 0.2 (0.5) 700 75 1 00025 10% S
FR-ABR-H1.5K 0.4 (0.9) 350 115 2 00040 10% S
FR-ABR-H2.2K 0.5 (1.1) 250 120 3 00060 10% S
FR-ABR-H3.7K 0.8 (1.8) 150 155 5 00090 10% S
FR-ABR-H5.5K 1.3 (2.9) 110 185 7 1/2 00120 10% S
FR-ABR-H7.5K 2.2 (4.9) 75 340 10 00170 10% S
FR-ABR-H11K 3.4 (7.5) 52 530 15 00230 6% S
FR-ABR-H15K
2.4 (5.3) x 2 36 (18 x 2) 870 20 00310 6% S
(2 resistors in series)
FR-ABR-22K 25 00380 6%
3.3 (6.6) x 2 26 (52 / 2) 1060 S
(2 resistors in parallel) 30 00440 6%

Instruction Manuals
Model Model Number Stocked Item
FR-ABR(H) IB(NA)66891 -
FR-BU2 IB(NA)0600292 -
FR-BU2-C IB(NA)0600379 -
UFS NT348E05 -

Mitsubishi Electric Automation | Variable Frequency Drives 431


n VARIABLE FREQUENCY DRIVES
Dynamic Braking Options
Select the brake unit according to the motor capacity.
To obtain braking torque greater than 200%, use a larger inverter capacity.
Up to 10 FR-BU2 brake units can be connected in parallel for increased braking capacity.

%ED or Time at Short-Time Rating When Braking Torque is 100%


Stocked Brake Resistor Stocked Motor Capacity (HP)
Brake Unit Model Number
Item Model Number Item 1 2 3 5 7.5 10 15 20 25 30 40 50 60 75
FR-BU2-1.5K S BU-1500-TEIKOUKI - 30 s - - - - - - - - - - - - -
FR-BU2-3.7K S BU-3700-TEIKOUKI - - 30 s - - - - - - - - - - - -
FR-BU2-7.5K S BU-7.5K-TEIKOUKI - - - 30 s 30 s - - - - - - - - - -
230V
FR-BU2-15K S FR-BR-15K-UL S - - - - 80% 40% 15% 10% - - - - - -
FR-BU2-30K S FR-BR-30K-UL S - - - - - - 65% 30% 25% 15% 10% - - -
FR-BU2-55K - FR-BR-55K-UL - - - - - - - - - 90% 60% 30% 20% 15% 10%
FR-BU2-H7.5K S 2 x BU-3700-TEIKOUKI - - - 30 s 30 s - - - - - - - - - -
FR-BU2-H15K S FR-BR-H15K-UL S - - - - 80% 40% 15% 10% - - - - - -
460V
FR-BU2-H30K S FR-BR-H30K-UL S - - - - - - 65% 30% 25% 15% 10% - - -
FR-BU2-H55K S FR-BR-H55K-UL S - - - - - - - - 90% 60% 30% 20% 15% 10%
FR-BR-C3.7K - - - 30% 10% - - - - - - - - - -
FR-BU2-C22K S FR-BR-C7.5K - - - - 40% 20% 10% - - - - - - - -
600V FR-BR-C22K - - - - - - 85% 40% 20% 15% 10% - - - -
2 x FR-BU2-C22K S 2 x FR-BR-C22K - - - - - - - - - - - - 15% - -
3 x FR-BU2-C22K S 3 x FR-BR-C22K - - - - - - - - - - - - - - 15%

Stocked Brake Resistor Stocked Motor Capacity (HP)


Brake Unit Model Number
Item Model Number Item 100 125 150 200 250 300 350 400 450 500 600 700 800
FR-BU2-H75K S MT-BR5-H75K - 10% 5% - - - - - - - - - - -
2 x FR-BU2-H75K S 2 x MT-BR5-H75K - 40% 25% 15% 10% 5% - - - - - - - -
3 x FR-BU2-H75K S 3 x MT-BR5-H75K - 90% 60% 40% 20% 14% 10% 5% 5% - - - - -
4 x FR-BU2-H75K S 4 x MT-BR5-H75K - - 95% 70% 40% 25% 15% 13% 10% 5% 5% - - -
460V
5 x FR-BU2-H75K S 5 x MT-BR5-H75K - - - - 60% 40% 25% 20% 15% 12% 10% 5% 5% -
6 x FR-BU2-H75K S 6 x MT-BR5-H75K - - - - 90% 55% 40% 25% 25% 15% 14% 10% 5% 5%
7 x FR-BU2-H75K S 7 x MT-BR5-H75K - - - - - 80% 55% 40% 35% 20% 15% 13% 10% 5%
8 x FR-BU2-H75K S 8 x MT-BR5-H75K - - - - - - 70% 50% 45% 30% 25% 15% 13% 10%

Braking Torque (%) at Short-Time Rating of 30 Sec. for 5HP and Less
Braking Torque (%) at Short-Time Rating of 15 Sec. for 7.5HP and Larger
Stocked Brake Resistor Stocked Motor Capacity (HP)
Brake Unit Model Number
Item Model Number Item 1 2 3 5 7.5 10 15 20 25 30 40 50 60 75
FR-BU2-1.5K S BU-1500-TEIKOUKI - 100% 50% - - - - - - - - - - - -
FR-BU2-3.7K S BU-3700-TEIKOUKI - - 100% 50% 50% - - - - - - - - - -
FR-BU2-7.5K S BU-7.5K-TEIKOUKI - - - 100% 100% - - - - - - - - - -
230V
FR-BU2-15K S FR-BR-15K-UL S - - - - 280% 200% 120% 100% 80% 70% - - - -
FR-BU2-30K S FR-BR-30K-UL S - - - - - - 260% 180% 160% 130% 100% 80% 70% -
FR-BU2-55K - FR-BR-55K-UL - - - - - - - - - 300% 250% 180% 150% 120% 100%
FR-BU2-H15K S FR-BR-H15K-UL S - - - - 280% 200% 120% 100% 80% 70% - - - -
460V FR-BU2-H30K S FR-BR-H30K-UL S - - - - - - 260% 180% 160% 130% 100% 80% 70% -
FR-BU2-H55K S FR-BR-H55K-UL S - - - - - - - - 300% 250% 180% 150% 120% 100%
FR-BR-C3.7K - - - 170% 100% - - - - - - - - - -
FR-BU2-C22K S FR-BR-C7.5K - - - 340% 200% 130% 100% - - - - - - - -
600V FR-BR-C22K - - - - - - 300% 200% 145% 120% 100% - - - -
2 x FR-BU2-C22K S 2 x FR-BR-C22K - - - - - - - - - - - - 120% - -
3 x FR-BU2-C22K S 3 x FR-BR-C22K - - - - - - - - - - - - - - 120%
Note: FR-BU2-C22K is not UL or cUL listed for use with the FR-BR-C resistor. If UL or cUL is required, use the ASC-RES-C22K in place of FR-BR-C22K.

Stocked Brake Resistor Model Stocked Motor Capacity (HP)


Brake Unit Model Number
Item Number Item 100 125 150 200 250 300 350 400 450 500 600 700 800
FR-BU2-H75K S MT-BR5-H75K - 100% 80% 65% 50% 40% 30% 28% 26% 22% 20% - - -
2 x FR-BU2-H75K - 2 x MT-BR5-H75K - 200% 165% 135% 100% 80% 65% 55% 53% 44% 40% 33% 28% 25%
3 x FR-BU2-H75K - 3 x MT-BR5-H75K - 300% 250% 200% 150% 120% 100% 85% 80% 65% 60% 50% 43% 37%
4 x FR-BU2-H75K - 4 x MT-BR5-H75K - - 300% 270% 200% 160% 135% 115% 105% 85% 80% 65% 55% 50%
460V
5 x FR-BU2-H75K - 5 x MT-BR5-H75K - - - 300% 250% 200% 170% 140% 130% 110% 100% 83% 70% 62%
6 x FR-BU2-H75K - 6 x MT-BR5-H75K - - - - 300% 240% 200% 170% 160% 130% 120% 100% 85% 75%
7 x FR-BU2-H75K - 7 x MT-BR5-H75K - - - - - 280% 235% 200% 185% 155% 140% 115% 100% 85%
8 x FR-BU2-H75K - 8 x MT-BR5-H75K - - - - - - 270% 230% 210% 175% 160% 130% 110% 100%

432
Dynamic Braking Unit & Resistor Specifications
Continuous
Weight Resistance
Brake Unit Model Number Stocked Item Brake Resistor Model Number Stocked Item Rated (Watts) Permissible
kg / lbs (Ohms)
Power (Watts)
FR-BU2-1.5K S BU-1500-TEIKOUKI - n/a 50 300 100
FR-BU2-3.7K S BU-3700-TEIKOUKI - n/a 30 900 300
FR-BU2-7.5K S BU-7.5K-TEIKOUKI - n/a 20 1800 600
230V
FR-BU2-15K S FR-BR-15K-UL S 15 / 33 8 4000 990
FR-BU2-30K S FR-BR-30K-UL S 30 / 66 4 8000 1990
FR-BU2-55K - FR-BR-55K-UL - 70 / 154 2 16000 3910
FR-BU2-H7.5K S 2 x BU-3700-TEIKOUKI - n/a 60 1800 600
FR-BU2-H15K S FR-BR-H15K-UL S 15 / 33 32 4000 990
460V FR-BU2-H30K S FR-BR-H30K-UL S 30 / 66 16 8000 1990
FR-BU2-H55K S FR-BR-H55K-UL S 70 / 154 8 16000 3910
FR-BU2-H75K S MT-BR5-H75K - 70 / 154 6.5 30000 7500

A700 Dynamic Braking Units and Resistors - UFS Series


• A more economical solution to regenerative braking applications.
• Internal Form-C relay
• Adjustable DC bus brake turn-on voltage
• Configurable master / slave brake configuration. Allows connection of up to 5 brake units (1 master / 4 slaves)

240V Series
Motor Capacity
Braking Hp 7.5 10 15 20 25 30 40 50 60 75
Torque kW 5.5 7.5 11 15 18.5 22 30 37 45 55
100% for Brake Unit UFS22J UFS40J 2 x UFS40J
15 secs. Brake Resistor RUFC15J RUFC22J RUFC40J 2 x RUFC40J
Continuous Permissible Power (W) UFS22J - 1500W UFS40J - 2000W 2ea x UFS40J - 4000W
Electrical
Resistance (Overall) RUFC15J - 24ohms RUFC22J - 12ohms RUFC40J - 7.5ohms 2ea x RUFC40J - 3.75ohms
Data
Continuous Current (Amps) 7A 10A 14.6A 29.2A

460V Series
Motor Capacity
Braking Hp 7.5 10 15 25 30 40 50 60 75
Torque kW 5.5 7.5 11 18.5 22 30 37 45 55
100% for Brake Unit UFS22 UFS40
15 secs. Brake Resistor RUFC15/480 RUFC22/480 RUFC40/480
Continuous Permissible Power (W) UFS22 - 2000W UFS40 - 4000W
Electrical
Resistance (Overall) RUFC15/480 - 44ohms RUFC22/480 - 27ohms RUFC40/480 - 15ohms
Data
Continuous Current (Amps) 6A 7.7A 14.6A

Motor Capacity
Braking Hp 100 125 150 175 215 300 375
Torque kW 75 90 110 132 160 220 280
100% for Brake Unit UFS110 2 X UFS110
15 secs. Brake Resistor RUFC110/480 2 X RUFC110/480
Continuous Permissible Power (W) UFS110 - 8000W 2 x UFS110 - 16000W
Electrical
Resistance (Overall) RUFC110/480 - 6.8ohms 2 x RUFC110/480 - 3.4ohms
Data
Continuous Current (Amps) 30.7A 61.4A

Dimensions
Height Width Depth Approximate Weight Stocked
Model Number
mm inches mm inches mm inches kg lbs Item
UFS20J S
250 9.8 175 6.9 2.5 5.5
UFS40J S
240V RUFC15J 240 9.5 100 3.9 2.8 6.2 S
RUFC22J 310 12.2 75 3 3.5 7.7 S
RUFC40J 365 14.4 4.3 9.5 S
UFS22 S
100 3.9 175 6.9 2.5 5.5
UFS40 250 9.8 S
UFS110 107 4.2 195 7.7 3.9 8.6 S
480V RUFC15/480 310 12.2 3.5 7.7 S
100 3.9 75 3
RUFC22/480 365 14.4 4.2 9.3 S
RUFC40/480 2 x 365 2 x 14.4 2 x 100 2 x 3.9 2 x 75 2x3 8.7 19.2 S
RUFC110/480 4 x 365 4 x 14.4 4 x 100 4 x 3.9 4 x 75 4x3 17.3 38.1 S

Mitsubishi Electric Automation | Variable Frequency Drives 433


n VARIABLE FREQUENCY DRIVES
A700 VFD Efficiency Values • ND Rating Based
240VAC 3-Phase Input 480VAC 3-Phase Input 600VAC 3-Phase Input
Factory Factory
Supplied Supplied
Rated Watts Rated Watts Rated Watts
Model Number Efficiency Model Number Efficiency DC Choke Model Number Efficiency DC Choke
Watts Loss Watts Loss Watts Loss
Watts Watts
Loss Loss
FR-A720-00030-NA 400 50 88% FR-A740-00015-NA 400 50 88% - FR-A760-00017-NA 750 40 95% -
FR-A720-00050-NA 750 70 91% FR-A740-00025-NA 750 65 91% - FR-A760-00040-NA 2200 70 97% -
FR-A720-00080-NA 1500 110 93% FR-A740-00040-NA 1500 75 95% - FR-A760-00061-NA 3700 110 97% -
FR-A720-00110-NA 2200 140 94% FR-A740-00060-NA 2200 100 95% - FR-A760-00120-NA 7500 160 98% -
FR-A720-00175-NA 3700 190 95% FR-A740-00090-NA 3700 150 96% - FR-A760-00220-NA 15000 260 98% -
FR-A720-00240-NA 5500 260 95% FR-A740-00120-NA 5500 200 96% - FR-A760-00330-NA 22000 410 98% -
FR-A720-00330-NA 7500 360 95% FR-A740-00170-NA 7500 250 97% - FR-A760-00550-NA 37000 650 98% -
FR-A720-00460-NA 11000 520 95% FR-A740-00230-NA 11000 300 97% - FR-A760-00840-NA 55000 940 98% -
FR-A720-00610-NA 15000 670 96% FR-A740-00310-NA 15000 400 97% - FR-A760-01040-NA 75000 1500 98% 100
FR-A720-00760-NA 18500 770 96% FR-A740-00380-NA 18500 550 97% - FR-A760-01310-NA 90000 1800 98% 120
FR-A720-00900-NA 22000 940 96% FR-A740-00440-NA 22000 650 97% - FR-A760-01520-NA 111000 2200 98% 140
FR-A720-01150-NA 30000 1050 97% FR-A740-00570-NA 30000 800 97% - FR-A760-02210-NA 132000 2600 98% 180
FR-A720-01450-NA 37000 1270 97% FR-A740-00710-NA 37000 1100 97% - FR-A760-02550-NA 185000 3200 98% 200
FR-A720-01750-NA 45000 1610 96% FR-A740-00860-NA 45000 1300 97% - FR-A760-03040-NA 220000 3700 98% 230
FR-A720-02150-NA 55000 1880 97% FR-A740-01100-NA 55000 1550 97% - FR-A760-04020-NA 280000 4800 98% 310
FR-A720-02880-NA 75000 2530 97% FR-A740-01440-NA 75000 1900 97% 130 FR-A760-04960-NA 355000 6000 98% 340
FR-A720-03460-NA 90000 3110 97% FR-A740-01800-NA 90000 2400 97% 130 FR-A760-06630-NA 400000 7500 98% 390
- - - - FR-A740-02160-NA 110000 2500 98% 140 - - - - -
- - - - FR-A740-02600-NA 132000 3000 98% 140 - - - - -
- - - - FR-A740-03250-NA 160000 4000 98% 170 - - - - -
- - - - FR-A740-03160-NA 185000 4200 98% 230 - - - - -
- - - - FR-A740-04320-NA 220000 5000 98% 240 - - - - -
- - - - FR-A740-04810-NA 250000 5500 98% 270 - - - - -
- - - - FR-A740-05470-NA 280000 6500 98% 300 - - - - -
- - - - FR-A740-06100-NA 315000 7000 98% 360 - - - - -
- - - - FR-A740-06830-NA 355000 8000 98% 360 - - - - -
- - - - FR-A740-07700-NA 400000 9000 98% 450 - - - - -
- - - - FR-A740-08660-NA 450000 10500 98% 450 - - - - -
- - - - FR-A740-09620-NA 500000 11500 98% 470 - - - - -
General Notes:
1. The amount of heat generated by the inverter is based on one inverter connected to one motor of the same capacity.
2. The amount of heat generated in the above table is the amount of heat generated when the inverter is operated at it’s rated current.
3. The amount of heat generated will decrease according to the motor load and usage (duty).
4. When using the external heat sink attachment watt loss decreases by 60%.

434
A701 Series
Vector VFD with built-in Line Regeneration.

• Ideal for applications with continuous • 5 programmable digital outputs


overhauling or large inertia loads (sink/source selectable)
• Capacity up to 75HP for 240V and 480V • 2 form C relays
applications • 3 analog inputs
• Braking Torque • Terminal 2 (0~5VDC, 0~10VDC,
- 100% continuous 0~20mA selectable)
- 150% for up to 60 sec. • Terminal 1 (0 to +/-5VDC or
• Vector mode with encoder allows Speed, 0 to ±10VDC selectable)
Torque and Position control • Terminal 4 (0~5VDC, 0~10VDC,
• Real Sensorless mode allows Speed and 4~20mA selectable)
Torque control without encoder • 2 analog outputs (0~10VDC and
• Starting torque of 150% at 0.3Hz pulse train out)
• 2 serial ports (RS485) and 1 USB port • Modbus RTU and Mitsubishi VFD
serial protocol communications
• 3 option ports for plug-in network or
function expansion options • UL and cUL listed. CE marked
(480V version only)
• 12 programmable digital inputs
(sink/source selectable)

FR-A721 – 5.5K Voltage

240V 7.5 – 75 Hp
Symbol Voltage Class Inverter capacity
A721 Three phase 240V class in kilowatts 480V 7.5 – 75 Hp
A741 Three phase 480V class 5.5K = 5.5KW
0.746kW = 1HP Horsepower

A701 Ratings
Note: There is no PLC function as included in the standard A700
Rating (CT & VT) IP00 Open Chassis Dimensions in inches (mm)
Weight Lbs (kg) Stocked Item
HP Rated Amps Model Number Height Width Depth
3-Phase 200~240VAC Input & Output
7 1/2 24 FR-A721-5.5K 18.5 (470) 9.9 (250) 10.7 (270) 44.1 (20) -
10 33 FR-A721-7.5K 18.5 (470) 9.9 (250) 10.7 (270) 48.5 (22) -
15 46 FR-A721-11K 21.6 (540) 11.9 (300) 11.6 (294) 72.7 (33) -
20 61 FR-A721-15K 21.6 (540) 11.9 (300) 11.6 (294) 77.1 (35) -
25 76 FR-A721-18.5K 23.7 (600) 15.4 (390) 12.6 (320) 110.2 (50) -
30 90 FR-A721-22K 23.7 (600) 15.4 (390) 12.6 (320) 114.6 (52) -
40 115 FR-A721-30K 27.6 (700) 17.8 (450) 13.4 (340) 152.0 (69) -
50 145 FR-A721-37K 27.6 (700) 18.5 (470) 14.5 (368) 191.7 (87) -
60 175 FR-A721-45K 27.6 (700) 18.5 (470) 14.5 (368) 198.3 (90) -
75 215 FR-A721-55K 35.5 (900) 23.7 (600) 16.0 (405) 264.4 (120) -
3-Phase 380~480VAC Input & Output
7 1/2 12 FR-A741-5.5K 18.5 (470) 9.9 (250) 10.7 (270) 55.1 (25) -
10 17 FR-A741-7.5K 18.5 (470) 9.9 (250) 10.7 (270) 57.3 (26) -
15 23 FR-A741-11K 21.6 (540) 11.9 (300) 11.6 (294) 81.5 (37) -
20 31 FR-A741-15K 21.6 (540) 11.9 (300) 11.6 (294) 88.1 (40) -
25 38 FR-A741-18.5K 23.7 (600) 14.2 (360) 12.6 (320) 105.8 (48) -
30 44 FR-A741-22K 23.7 (600) 14.2 (360) 12.6 (320) 108.0 (49) -
40 57 FR-A741-30K 27.6 (700) 17.8 (450) 13.4 (340) 143.2 (65) -
50 71 FR-A741-37K 27.6 (700) 18.5 (470) 14.5 (368) 176.3 (80) -
60 86 FR-A741-45K 27.6 (700) 18.5 (470) 14.5 (368) 182.9 (83) -
75 110 FR-A741-55K 35.5 (900) 23.7 (600) 16.0 (405) 253.3 (115) -

Mitsubishi Electric Automation | Variable Frequency Drives 435


n VARIABLE FREQUENCY DRIVES
A701 General Specifications
Soft-PWM control/high carrier frequency PWM control (selectable from among V/F control, advanced magnetic flux vector control and
Control Method real sensorless vector control) / vector control (*1)
Output Frequency Range 0.2 to 400Hz (The maximum frequency is 120Hz under real sensorless vector control and vector control.) (*1)
Frequency 0.015Hz/0 to 60Hz (terminal 2, 4: 0 to 10V/12bit); 0.03Hz/0 to 60Hz (terminal 2, 4: 0 to 5V/11bit, 0 to 20mA/about 11bit, terminal 1: 0 to ±10V/12bit)
Analog Input
Setting 0.06Hz/0 to 60Hz (terminal 1: 0 to ±5V/11bit)
Resolution Digital Input 0.01Hz
Frequency Analog Input Within ±0.2% of the max. output frequency (25°C ±10°C)
Accuracy Digital Input Within 0.01% of the set output frequency
Voltage / Frequency Base frequency can be set from 0 to 400Hz Constant torque/variable torque pattern or adjustable 5 points V/F can be selected
Characteristics
Starting Torque 150% 0.3Hz (under real sensorless vector control or vector control) (*1)
Torque Boost Manual torque boost
Acceleration / Deceleration 0 to 3600s (acceleration and deceleration can be set individually), linear or S-pattern acceleration/deceleration mode, backlash
Time Setting measures acceleration/deceleration can be selected.
DC Injection Brake Operation frequency (0 to 120Hz), operation time (0 to 10s), operation voltage (0 to 30%) variable
Stall Prevention Operation Operation current level can be set (0 to 220% adjustable), whether to use the function or not can be selected
Level
Torque Limit Level Torque limit value can be set (0 to 400% variable)
Frequency Analog Input Terminal 2, 4: 0 to 10V, 0 to 5V, 4 to 20mA (0 to 20mA) can be selected • Terminal 1: -10 to +10V, -5 to +5V can be selected
Setting
Signal Digital Input Input using the setting dial of the operation panel or parameter unit; Four-digit BCD or 16 bit binary (when used with option FR-A7AX)
Start Signal Forward and reverse rotation or start signal automatic self-holding input (3-wire input) can be selected.
You can select any twelve signals using Pr. 178 to Pr. 189 (input terminal function selection) from among multi speed selection, remote setting, stop-
Operation Specifications

on-contact, second function selection, third function selection, terminal 4 input selection, JOG operation selection, selection of automatic restart after
instantaneous power failure, flying start, external thermal relay input, PU operation/external inter lock signal , external DC injection brake operation start, PID
control enable terminal, brake opening completion signal, PU operation/external operation switchover, load pattern selection forward rotation reverse rotation
Input Signal boost, V/F switching, load torque high-speed frequency, S-pattern acceleration/deceleration C switchover, pre-excitation, output stop, start self-holding
selection, control mode changing, torque limit selection, start-time tuning start external input, torque bias selection 1, 2 (*1), P/PI control switchover, forward
rotation command, reverse rotation command, inverter reset, PTC thermistor input, PID forward reverse operation switchover, PU-NET operation switchover,
NET-external operation switchover, and command source switchover, conditional position pulse train sign (*1), conditional position droop pulse clear (*1),
magnetic flux decay output shutoff.
Pulse Train Input 100kpps
Maximum/minimum frequency setting, frequency jump operation, external thermal relay input selection, polarity reversible operation, automatic
restart after instantaneous power failure operation, electronic bypass operation, forward/reverse rotation prevention, remote setting, brake sequence,
second function, third function, multi-speed operation, original operation continuation at instantaneous power failure, stop-on-contact control,
Operational Functions load torque high speed frequency control, droop control, regeneration avoidance, slip compensation, operation mode selection, offline auto tuning
function, online auto tuning function, PID control, computer link operation (RS-485), motor end orientation (*1), pre-excitation, notch filter, easy gain
tuning, speed feed forward, and torque bias (*1)
You can select any signals using Pr. 190 to Pr. 196 (output terminal function selection) from among inverter running, up-to-frequency, instantaneous
power failure/undervoltage, overload warning, output frequency (speed) detection, second output frequency (speed) detection, third output frequency
(speed) detection, electronic thermal relay function pre-alarm, PU operation mode, inverter operation ready, output current detection, zero current
detection, PID lower limit, PID upper limit, PID forward rotation reverse rotation output, electronic bypass MC1, electronic bypass MC2, electronic
Operating bypass MC3, orientation complete (*1), brake opening request, fan fault output, heatsink overheat pre-alarm , inverter running/start command on,
Status deceleration at an instantaneous power failure, PID control activated, during retry, PID output interruption, life alarm, fault output 1, 2, 3 (power-off
signal), power savings average value update timing, current average monitor, maintenance timer alarm, remote output, forward rotation output (*1),
Output reverse rotation output (*1), low speed output, torque detection, regenerative status output (*1), start-time tuning completion, in-position completion
Signals (*1), alarm output and fault output. Open collector output (5 points), relay output (2 points) and alarm code of the inverter can be output (4 bit) from
the open collector.
When used
with the In addition to the above, you can select any signals using Pr. 313 to Pr. 319 (extension output terminal function selection) from among control circuit
FR-A7AY, capacitor life, main circuit capacitor life, cooling fan life, inrush current limit circuit life. (only positive logic can be set for extension terminals of the
FR-A7AR FR-A7AR)
(optional)
Pulse Train Input 500kpps
Select any signals using Pr. 54 FM terminal function selection (pulse train output) and Pr. 158 AM terminal function selection (analog output)
from among output frequency, motor current (steady or peak value), output voltage, frequency setting, operation speed, motor torque, converter
Pulse / Analog Output output voltage (steady or peak value), electronic thermal relay function load factor, input power, output power, load meter, motor excitation current,
reference voltage output, motor load factor, power saving effect, PID set point, PID measured value, motor output, torque command, torque current
command, and torque monitor.
Output frequency, motor current (steady or peak value), output voltage, frequency setting, running speed, motor torque, overload, converter output
voltage (steady or peak value), electronic thermal relay function load factor, input power, output power, load meter, motor excitation current,
Operating cumulative energization time, actual operation time, motor load factor, cumulative power, energy saving effect, cumulative saving power, PID set
PU (FR- Status point, PID measured value, PID deviation, inverter I/O terminal monitor, input terminal option monitor (*2), output terminal option monitor (*2),
Indication

DU07 / option fitting status (*3), terminal assignment status (*3), torque command, torque current command, feed back pulse (*1),motor output
FR-PU07 /
FR-PU04) Fault Fault definition is displayed during the fault occurs, the output voltage/current/frequency/cumulative energization time right before the
Definition fault occurs and past 8 fault definitions are stored.
Interactive Operation guide/trouble shooting with a help function (*3)
Guidance
Overcurrent during acceleration, overcurrent during constant speed, overcurrent during deceleration, overvoltage during acceleration, overvoltage
during constant speed, overvoltage during deceleration, inverter protection thermal operation, motor protection thermal operation, heatsink overheat,
instantaneous power failure occurrence, undervoltage, input phase failure, motor overload, output side earth (ground) fault overcurrent, output
short circuit, main circuit element overheat, output phase failure, external thermal relay operation (*5), PTC thermistor operation (*5), option alarm,
parameter error, PU disconnection, retry count excess (*5), CPU alarm, operation panel power supply short circuit, 24VDC power output short
Protective / Warning Function circuit, output current detection value excess (*5), inrush current limit circuit alarm, communication alarm (inverter), opposite rotation deceleration
error*5, analog input error, fan fault, overcurrent stall prevention, overvoltage stall prevention, electronic thermal relay function prealarm, PU stop,
maintenance timer alarm (*2) (*5), parameter write error, copy operation error, operation panel lock, parameter copy alarm, speed limit indication,
signal loss detection (*1) (*5), speed deviation large (*1) (*5), overspeed (*1) (*5), excessive position error (*1) (*5), brake sequence error (*5),
encoder phase error (*1) (*5), regeneration converter overcurrent, regeneration converter circuit fault, regeneration converter transistor protection
thermal
Ambient Temperature -10°C to +50°C (non-freezing)
Environment

Ambient Humidity 90%RH maximum (non-condensing)


Storage Temperature (*4) -20°C to +65°C
Atmosphere Indoors (without corrosive gas, flammable gas, oil mist, dust and dirt etc.)
Altitude / Vibration Maximum 1000m above sea level, 5.9m/s2 or less
Notes:
1. Available only when the option (FR-A7AP) is mounted
2. Can be displayed only on the operation panel (FR-DU07).
3. Can be displayed only on the parameter unit (FR-PU07/FR-PU04).
4. Temperature applicable for a short period in transit, etc.
5. This protective function does not function in the initial status.

436
A701 Terminal Connection Diagram

Sink logic
Main circuit terminal P/+ N/-
Control circuit terminal *6 *6
MCCB MC
R/L1 Inrush current
Three-phase AC S/L2 limit circuit
power supply U Motor
T/L3
V
IM
R1/L11 W
Jumper
*1 S1/L21 Earth (Ground)
*1. To supply power to the
control circuit separately, Main circuit *6. Do not connect any options to P/+ and
remove the jumper across Earth N/-.
R1/L11 and S1/L21. (Ground) Control circuit
Control input signals (No voltage input allowed) C1 Relay output
Forward STF
Terminal functions vary with rotation
the input terminal B1 Terminal functions
start Relay output 1 vary with the output
assignment (Pr. 178 to Pr. 189) Reverse STR
rotation (Fault output) terminal assignment
A1
start STOP (Pr. 195, Pr. 196)
Start self-
holding selection C2
RH
High speed
B2
Multi-speed Middle RM Relay output 2
selection speed A2
RL
*2. JOG terminal can be used
Low speed
as pulse train input terminal. Open collector output
Use Pr. 291 to select JOG *2 RUN
JOG/pulse. Jog mode Running
Terminal functions
RT SU
Second function selection Up to frequency vary with the output
terminal assignment
*3. AU terminal can be MRS IPF Instantaneous (Pr. 190 to Pr. 194)
Output stop power failure
used as PTC input
terminal. RES *3 OL
Reset Overload
AU
Terminal 4 input selection AU FU
(Current input selection) Frequency detection
CS PTC
SOURCE

Selection of automatic restart SE Open collector output common


after instantaneous
SINK

power failure SD Sink/source common


Contact input common 24V *7. It is not necessary when *8. FM terminal can be
calibrating the indicator used for pulse train
24VDC power supply PC output of open
from the operation panel.
PU collector output
(Common for external power supply transistor) using Pr.291.
*4 Voltage/current connector
input switch *9. Because the FR Configurator has not
worked with the FR-A701 series, a USB
Frequency setting signal (Analog) 10E(+10V) 4 2 connector can not be used.
ON USB +
10(+5V) OFF - Indicator
3 connector
Frequency setting FM (Frequency meter, etc.)
2 0 to 5VDC (Initial value) *8
potentiometer 2 0 to 10VDC selected Calibration
*9 Moving-coil type
1/2W1kΩ 0 to 20mADC
*4 SD resistor *7
5 1mA full-scale
*5 1
(Analog common)
*4. Terminal input specifications AM (+) Analog signal output
can be changed by analog
5 (0 to 10VDC)
input specifications 0 to ±10VDC (Initial value) (-)
switchover (Pr. 73, Pr. 267). Auxiliary (+) 1
Set the voltage/current input input (-) 0 to ±5VDC selected *4
switch in the OFF position to TXD+ RS-485 terminals
Terminal 4 to 20mADC (Initial value)
select voltage input (0 to 5V/0
4 input (+) 4 0 to 5VDC selected *4 TXD- Data transmission
to10V) and ON to select
current input (4 to 20mA).
(Current (-) 0 to 10VDC
input) RXD+
Connector RXD- Data reception
for plug-in option
Option connector 1
connection SG
Option connector 2 GND
*5. It is recommended to use 2W1kΩ
when the frequency setting signal Option connector 3
is changed frequently.
Terminating
resistor VCC 5V (Permissible load
current 100mA)

A701 Control Terminal Layout


A1 B1 C1 A2 B2 C2 10E 10 2 5 4

RL RM RH RT AU STOP MRS RES SD FM AM 1

SE RUN SU IPF OL FU SD SD STF STR JOG CS PC

Mitsubishi Electric Automation | Variable Frequency Drives 437


n VARIABLE FREQUENCY DRIVES
A701 Options
Function/Options Instruction Manuals

Model No. Stocked Item Description Model Number


FR-A701 Applied Manual - Contains wiring details, VFD layout
120VAC Control Input FR-A7AC S
drawings, alarm definitions and complete parameter list with IB(NA)0600337
Analog I/O FR-A7AN S definitions and setting examples
Encoder Feedback FR-A7AP S FR-A701 Basic Manual - Contains wiring details, VFD layout
IB(NA)0600331
Encoder Pulse Dividing Output FR-A7AL S drawings, alarm definitions and parameter list
Relay Output FR-A7AR S FR-PU07 - Contains complete instruction sets and screen
Function

IB(NA)0600240
12 Bit Digital Input FR-A7AX S definitions
Digital Output Manuals available for download at www.meau.com
FR-A7AY S
Ext. Analog Output
BiPolar Analog Output Building Management Options
High Res Analog Input FR-A7AZ -
FR-A7N-ETH FR-A7N-XLT ETH-1000 XLTR-1000
Motor Thermistor Network Type / Model
(*2,*3,*4) (*2,*3,*4) (*5,*6) (*5,*6)
CC-Link FR-A7NC S BACnet/IP X - X -
EtherNet/IP X - X -

Communication
ControlNET (*1) FR-A7NCN S
Communication

Modbus TCP X - X -

Gateway
DeviceNet FR-A7ND S
PROFINET IO X - X -
EtherNet/IP (*1) FR-A7NE S BACnet MS/TP - X X X
LonWorks FR-A7NL S Metasys N2 - X X X
Profibus DP FR-A7NP S Siemens FLN - X - -
SSCNET III FR-A7NS S Stocked Item S S - -
Notes:
Note: 1. A701 series supports only the above listed plug-in options. 1. For additional information, visit www.iccdesigns.com
Those options not listed cannot be used with the A701 series. 2. Physically mounts within VFD and powered by VFD
3. Deep control cover is required
4. FR-E7TR option recommended. (PU connector not available for use)
5. Communication to multiple VFD’s is possible
6. Mounted and powered external to VFD

Parameter Units / Parameter Copy Units


Parameter units are used for operator control, reading and writing
parameters, and drive monitoring. Parameter Copy Units also read the
drive parameter settings and copy them into non-volatile memory, and
can write them into other drives.
Stocked
Model Number Description
Item
FR-CB201 Extension cable straight plugs on both ends - 1 meter S
FR-CB203 Extension cable straight plugs on both ends - 3 meters S
FR-CB205 Extension cable straight plugs on both ends - 5 meters S
FR-DU07 Control Panel for F700 S
LCD Multi-lingual Parameter Copy Unit (English, French,
Spanish, German, Italian, Swedish, Finnish, Japanese)
FR-PU07 for operator control, parameter read/write and moni- S
toring. Stores settings in non-volatile memory. Built-in
parameter copy capability. (F/A700 based)
FR-ADP FR-DU07 panel mounting adapter S
LCD Multi-lingual Parameter Copy Unit (English, French,
FR-PU04 Spanish, German, Italian, Swedish, Finnish, Japanese) for S
operator control, parameter read/write and monitoring.
SC-FRPC Serial Communication Cable S
FR-PU07BB-L Battery Powered PU07 S
FR-RJ45-HUB4 Serial Network Hub - 2 Stations -
FR-RJ45-HUB10 Serial Network Hub - 8 Stations -
FR-RJ45-TR Terminating Resistor for FR-RJ45-HUB -

Software
Model Number Description Stocked Item
Programming and diagnostic software
FR-CONFIGURATOR S
(ver. 3.20 or greater)

438
V500 Series
Variable Frequency Drives True, Closed Loop Vector Control
This series achieves high precision and fast response that exceeds the performance of conventional
general-purpose inverters. They can be used in specialized applications such as line control and elevators.

By incorporating our original all-digital vector control, • 4-Quadrant torque control standard
high starting torque and high speed response have • Multiple parameters for tailoring to a wide variety
been made possible for both velocity and torque control of applications
modes.
• Simple positioning included as standard
• 2 to 75 Horsepower at 240V • DC Link Reactor standard (V500L)
• 2 to 75 Horsepower at 480V • Peripheral devices such as power regenerative
• 100% continuous torque at Zero speed converter (FR-CV, FR-RC, MT-RC) available
• Auto Tuning to other manufacturer’s constant torque • Communications options: DeviceNet, Profibus DP,
motor with encoder CC-Link, Modbus Plus, SSCNet
• Easy to use Parameter Unit

Constant Torque Constant Torque


Model Number Stocked Item Model Number Stocked Item
Hp Output Amps Hp Output Amps
3-Phase 240VAC Input / Output 3-Phase 480VAC Input / Output
2 9.0 FR-V520-1.5K-NA S 2 4.5 FR-V540-1.5K-NA S
3 13.0 FR-V520-2.2K-NA S 3 6.5 FR-V540-2.2K-NA S
5 20.0 FR-V520-3.7K-NA S 5 10.0 FR-V540-3.7K-NA S
7.5 28.5 FR-V520-5.5K-NA - 7.5 14.5 FR-V540-5.5K-NA -
10 37.5 FR-V520-7.5K-NA - 10 18.5 FR-V540-7.5K-NA -
15 54 FR-V520-11K-NA - 15 27.5 FR-V540-11K-NA S
20 72.8 FR-V520-15K-NA - 20 35.5 FR-V540-15K-NA S
25 88 FR-V520-18.5K-NA - 25 44.0 FR-V540-18.5K-NA -
30 103.5 FR-V520-22K-NA S 30 51.8 FR-V540-22K-NA -
40 126.5 FR-V520-30K-NA - 40 67.0 FR-V540-30K-NA -
50 166.8 FR-V520-37K-NA - 50 86.0 FR-V540-37K-NA S
60 198.0 FR-V520-45K-NA - 60 99.0 FR-V540-45K-NA S
75 264.0 FR-V520-55K-NA - 75 132.0 FR-V540-55K-NA -

V500 Ratings 240V Class 1.5K - 55K


Model FR-V520-_ _K-NA 1.5 2.2 3.7 5.5 7.5 11 15 18.5 22 30 37 45 55

Horsepower Rating (Hp) 2 3 5 7.5 10 15 20 25 30 40 50 60 75

Rated Current (A) 9.0 13.0 20.0 28.5 37.5 54.0 72.8 88.0 103.5 126.5 166.0 198.0 264.0
Overload Current Rating (*1) 150% 60 sec., 200% 0.5 sec. (inverse time characteristics)
Output
Voltage (*2) 3-Phase 200-220V 50 Hz, 200-240V 60 Hz 3-Phase 200-220V 50 Hz, 200-230V 60 Hz

Max. Time 100%/5 sec. 20% (*5)


Regenerative
Breaking Torque Tolerable
3% ED (*5) 2% ED (*5) Continuous (*5)
Work Rate

Rated Input, AC Volt. and


3-Phase 200-220 V 50 Hz, 200-240V 60 Hz 3-Phase 200-220 V 50 Hz, 200-230V 60 Hz
Frequency

Tolerable AC Voltage Fluctuation 170-242V 50 Hz, 200-264V 60 Hz 170-242V 50 Hz, 170-253V 60 Hz


Power
Supply Tolerable Frequency Fluctuation ±5%

Amount of Instantaneous Voltage


When operated at or above 165 V continuously and voltage falls from rated voltage to under 165 V, 15 ms of continuous operation
Drop that can be Withstood
Supply (kVA) (*3) 5.0 6.5 10 14 19 23 33 39 48 57 77 90 123
Protective Structure (JEM 1030) Enclosed type (IP20) (*4) Open type (IP00)
Cooling Method Forced air cooling
kg 3.5 3.5 6 6 6 14 14 21 30 40 40 55 58
Approximate Weight
lbs 7.7 7.7 13.2 13.2 13.2 30.8 30.8 46.2 66 88 88 121 128
mm 150 150 220 220 250 250 250 250 340 450 450 480 480
Width
inches 5.9 5.9 8.7 8.7 9.9 9.9 9.9 9.9 13.4 17.7 17.7 18.9 18.9
mm 260 260 260 260 400 400 400 400 550 550 550 700 700
Height
inches 10.2 10.2 10.2 10.2 15.8 15.8 15.8 15.8 21.7 21.7 21.7 27.6 27.6
mm 163 163 193 193 218 218 218 218 195 250 250 250 270
Depth
inches 6.4 6.4 7.6 7.6 8.6 8.6 8.6 8.6 7.7 9.9 9.9 9.9 10.6
Notes: See next page.
Mitsubishi Electric Automation | Variable Frequency Drives 439
n VARIABLE FREQUENCY DRIVES
V500 Ratings 480V Class 1.5K - 55K
Model FR-V540-_ _K-NA 1.5 2.2 3.7 5.5 7.5 11 15 18.5 22 30 37 45 55
Horsepower Rating (Hp) 2 3 5 7.5 10 15 20 25 30 40 50 60 75
Rated Current (A) 4.5 6.5 10.0 14.5 18.5 27.5 35.5 44.0 51.8 67.0 86.0 99.0 132.0
Overload Current Rating (*1) 150% 60 sec., 200% 0.5 sec. (inverse time characteristics)
Output Voltage (*2) 3-Phase 380-480V 50 Hz/60 Hz
Max. Time 100% / 5 sec. 20% (*5)
Regenerative
Breaking Torque Tolerable 2% ED (*5) Continuous (*5)
Work Rate
Rated Input, AC Volt. and
3-Phase 380-480 V 50 Hz/60 Hz
Frequency
Tolerable AC Voltage Fluctuation 323-528V 50 Hz/60 Hz
Power
Tolerable Frequency Fluctuation ±5%
Supply
Amount of Instantaneous Voltage
When operated at or above 320 V continuously and voltage falls from rated voltage to under 320 V, 15 ms of continuous operation
Drop that can be Withstood
Supply (kVA) (*3) 5.0 6.5 10.2 14 19 23 33 39 48 57 77 90 123
Protective Structure (JEM 1030) Enclosed type (IP20) (*4) Open type (IP00)
Cooling System Forced air cooling
kg 3.5 3.5 6 6 14 14 14 14 30 35 35 36 65
Approximate Weight
lbs 7.7 7.7 13.2 13.2 30.8 30.8 30.8 30.8 66 77 77 79 143
mm 150 150 220 220 250 250 250 250 340 450 450 480 480
Width
inches 5.9 5.9 8.7 8.7 9.9 9.9 9.9 9.9 13.4 17.7 17.7 18.9 18.9
mm 260 260 260 260 400 400 400 400 550 550 550 700 700
Height
inches 10.2 10.2 10.2 10.2 15.8 15.8 15.8 15.8 21.7 21.7 21.7 27.6 27.6
mm 163 163 193 193 218 218 218 218 195 250 250 250 270
Depth
inches 6.4 6.4 7.6 7.6 8.6 8.6 8.6 8.6 7.7 9.9 9.9 9.9 10.6
Notes:
1. The overload current % value indicates the percentage to the inverter’s rated output current. For repeated duty, allow time for the inventer and motor to return to or below the temperature when at
100% load.
2. The maximum output voltage cannot exceed the power supply voltage. The maximum output voltage can be set below the power supply voltage.
3. The power capacity will vary according to the power supply side impedance (including input reactor and power lines) value.
4. When the wiring cover for the network option is removed and built-in options are installed, the protective structure will become open type (IP00).
5. For inverter capacities 1.5K to 15K, using the optional high-duty brake resistor (FR-ABR) will provide 100% torque/10% ED.

Dedicated Options V500 Series


Model
Description Installation Manual Stocked Item
Number
Parameter unit used for operation control, reading and writing parameters, drive monitoring, parameter copy and
FR-PU04V IB(NA)0600079 S
multi-language
FR-V5AP Pulse train input for advanced position control. Differential line receiver: 500kpps, open collector 200kpps IB(NA)0600087 S
FR-V5AX 6 additional multi-function digital inputs and high resolution analog input (16-bit) IB(NA)0600083 -
FR-V5AY 3 additional multi-function digital outputs and encoder pulse ratio output (differential or open collector output) IB(NA)0600085 -
FR-V5AM When used with additional encoder, machine side orientation can be performed IB(NA)0600089 -
FR-V5NS SSCNET motion control network operation IB(NA)0600106E S
FR-V5NE Ethernet option for inverter setup and monitoring using LAN IB(NA)0600108E -
FR-V5AH 3-digit BCD or 12-bit binary code input for high accuracy speed control IB(NA)0600110E -
T-TRC50 Memory option used with setup software (FR-SW1-SETUP-WE) to analyze internal inverter trace data Contact MEAU -

SSCNET II Cables Instruction Manuals


Model Number Length Description Stocked Item Model Model Number
FR-V5NSCBL005 0.5 meter S FR-V520 Basic IB(NA)06000064
FR-V5NSCBL01 1 meter S FR-V540 Detailed IB(NA)06000065
Connection of Q172CPU
FR-V5NSCBL05 5 meters to FR-V5NS, FR-V5NS to S Basic IB(NA)0600134
FR-V560
FR-V5NSCBL10 10 meters FR-V5NS - Detailed IB(NA)0600135
Basic IB-T7311
FR-V5NSCBL20 20 meters - FR-V500L
Detailed IB-T7312

440
V500 General Specifications
Control Specifications
Control System Soft- PWM control or high carrier frequency sine-wave PWM control can be selected. Vector control or V/F control can be selected.
Control Mode Speed control, torque control, position control
Analog
0.03% of maximum set speed
Frequency Control Input
Resolution Digital
0.003% against maximum settings (0.1 rpm units for minimum setting)
Input
Acceleration / Deceleration Time 0 to 3600 sec (0.1 second increments)
Acceleration / Deceleration
Linear, S pattern (3 types) or backlash compensation acceleration/deceleration can be selected
Pattern
Torque Restriction Level Torque restriction value can be set (0 to 400% variable)
Input Signal
Terminal No. Setting Range Speed Control Torque Control
0 to 10V
2 Main speed setting Speed restriction
(resolution 0.03%)
Analog Setting Signal Auxiliary speed setting, magnetic
0 to ±10V Speed restriction compensation, magnetic flux command,
1 flux command regenerative torque
(resolution 0.05%) driving side speed restriction
restriction
0 to ±10V
3 Torque restriction (Torque bias) Torque command
(resolution 0.05%)
Main speed setting (in this case,
0 to ±10V Speed restriction (at this time, terminal 2 is invalid)
With Option FR-V5AX 6 terminals 1 and 2 are invalid)
(resolution 0.003%) Torque command (at this time, terminal 3 is valid)
Torque restriction
Environment
3 fixed function
Forward rotation command, alarm reset, external thermal relay
terminals
Contact Signal
5 multi-function Selection can be made from reverse rotation command, multi-speed setting (max. 15 speeds), remote setting, jog operation,
terminals second function selection, third function selection, output stop, three-wire control, pre-excitation, control mode switchover,
torque restriction selection, S pattern switchover, PID control terminal, orientation command, brake opening completion
6 multi-function signal, PU operation/external operation switchover, torque bias selection 1, torque bias selection 2, P control selection, servo
With Option (FR-V5AX)
terminals on, HC connection, PU/external interlock, external DC brake start, and commanded position selection
1 Form C Relay
Contact Signal (230VAC 0.3A,
30VDC 0.3A) Selection con be made from inverter running, up to speed, instantaneous power failure (undervoltage) speed detection,
3 multi-function second speed detection, third speed detection, PU operation mode, overload alarm, regenerative brake pre-alarm,
Open Collector Signal
terminals electronic thermal relay pre-alarm, output current detection, zero current detection, PID lower limit, PID upper limit,
3 multi-function PID forward /reverse output, operation ready, operation ready 2. brake opening request, fan fault output, fin overheat
With Option (FR-V5AY)
terminals pre-alarm, orientation in-position, forward rotation output, reverse rotation output, low speed output, torque detection,
1 multi-function regenerative status output, minor fault output, alarm output, maintenance timer output, remote output, speed detection,
With Option (FR-V5AM) in-position and trace status
terminal
7 multi-function
With Option (FR-A5AY)
terminals
0 to ±10V, 12 bits x
Analog Output 1CH 0 to 10V, 12 bits
x 1CH Selection can be made from speed, output current, output voltage, preset speed, output frequency, motor torque, converter
output voltage, regenerative brake duty, electronic thermal relay load factor, output current peak value, converter output
0 to ±10V, 10 bits x voltage peak value, load meter, motor exciting current, motor output, reference voltage
With Option (FR-A5AY) 1CH 0 to 20mA, 10
bits x 1CH
Encoder Pulse Output Option
A phase, B phase, Z phase, (A and B phases can be divided) Open collector/differential line driver
(FR-V5AY)
Maximum/minimum speed setting, speed jump, external thermal relay input selection, polarity reversible operation, override function, automatic
restart operation after instantaneous power failure, forward/reverse operation prevention, operation mode selection, offline auto tuning function,
Operational Functions online auto tuning function, easy gain tuning, computer link operation, remote setting, brake sequence, second function, third function, multi-speed
operation, coasting to stop, power failure stop, PID control, speed feed forward, model adaptive speed control, master/slave, torque bias, 12-bit
digital command (FR-A5AX option), pulse train input (FR-A5AP option), motor thermistor interface (FR-V5AX option), and simple positioning
Ambient Temperature -10°C to +50°C (Non-freezing) / 14°F to 122°F
Ambient Humidity 90% RH or less (Noncondensing)
Storage Temperature (*1) -20°C to +65°C / -4°F to 149°F
Atmosphere For indoor use; no corrosive gasses, flammable gasses, oil mist, dust or dirt present
Attitude 1000m above sea level. Contact factory for higher altitude deratings.
Vibration 5.9 m/s² (0.6G max.) based on JIS C 0911
Display
Selection can be made from speed, output current, output voltage, preset speed, output frequency, motor torque, converter output voltage,
Parameter Unit (FR-DU04-1/ regenerative brake duty, electronic thermal relay load factor, output current peak value, converter output voltage, peak value, input terminal
FR-PU04V) status (PU04V), load meter, motor exciting current, position pulse, cumulative energization time, actual operation time, motor load factor, torque
command, torque current command, feedback pulse, motor output, trace status
Alarm definition is displayed when protective function is activated. 8 past alarm definitions are stored.
Alarm Definition
(Only 4 alarm definitions are stored in the DU04-1)
Overcurrent shut-off (acceleration, deceleration, constant speed), regenerative overvoltage shut-off (acceleration, deceleration, constant speed),
undervoltage, instantaneous power failure, overload shut-off (electronic thermal relay), brake transistor alarm, earth (ground) fault current, power
Protective Functions output short circuit, stall prevention, external thermal relay, fin overheat, fan fault, option alarm, parameter error, PU disconnection, encoder
no-signal, large speed deviation, overspeed large position error, CPU error, encoder phase error, output phase loss excessive retries,
brake sequence error
Note:
1. Temperature that can be applied for short times, such as in transit.

Mitsubishi Electric Automation | Variable Frequency Drives 441


n VARIABLE FREQUENCY DRIVES
V500 Series Terminal Connection Diagram

Notes:
1. Terminal PR is provided on the 15kW and smaller capacities, and terminal PX is provided on the 5.5kW and smaller capacities.
2. When using FR-ABR with the 5.5kW or smaller capacity, remove this jumper.
3. Remove this jumper when using FR-BEL for 55kW and smaller capacities. DC link reactor included with 75kW and larger.
4. The converter’s life will be shortened by repeated in-rush currents when the power is turned ON, so do not turn the power ON and OFF frequently.
5. Prepare a ± 10V external power supply for terminals 1 and 3.
6. When using a motor without a thermal protector, set Pr.876 “Thermal protector input” to 0 and set Pr.9 (Pr.452) “Electronic thermal (2nd electronic thermal).
7. The terminal functions can be changed with the input terminal function selection (Pr.180 to Pr.183, Pr.187)
8. The terminal functions can be changed with the output terminal function selection (Pr.190 to Pr.192, Pr.195)
9. Change the connector according to the encoder power supply specifications.
10. The sink logic and source logic will change when the connector is changed.
11. Use of the 2W1kW is recommended when the settings are changed frequently.
12. Always ground the inverter and motor.

442
Engineered Solutions
Manufactured to the highest standards in UL approved facilities, The Engineered Solutions program takes Mitsubishi’s high performance control
products and engineers them into ready-to-use form.

Standard Engineered Solutions


Based on many years of practical industry experience, Standard Engineered Solutions are pre-engineered to meet the needs of a wide range of
different applications within industrial, agricultural and commercial sectors, ensuring low cost and quick delivery.

Custom Engineered Solutions


Mitsubishi designs and constructs fully customized Engineered Solutions that meet the most exacting specifications. A Custom Packaged
Solution could be anything from a single enclosure to a complete shipping container full of pre-commissioned control equipment, and can be
made to US requirements or to meet the standards of any other country around the world
Every Package is supplied with full documentation and is backed up with a comprehensive 2 year warranty.

Custom Engineered Solutions Offer:


• Competitive and innovative designs • Designs archived for future reference or repeat orders
• Solutions built to your exact specifications • Field installation and start-up services
• Integrated VFD panels from 1/8th HP to 1000 HP • A full range of Mitsubishi Electric equipment integrated
• Support from factory trained engineers with 3rd party products
• Help with interpreting specfications • Technical support and advice from beginning to end
• Global standards compliance - UL, cUL, CSA, CE • Complete solutions covered by 2 year warranty
• Full documentation including AutoCAD drawings

Custom Engineered Solutions offer the performance and reliability of Mitsubishi products in
packages tailored to your exact specification.

Mitsubishi Electric Automation | Variable Frequency Drives 443


n VARIABLE FREQUENCY DRIVES
FR-F700 Based VFD Complete Bypass System - NEMA 1, NEMA 12, NEMA 3R
Base System Includes:
• PowerGate bypass controller with LCD display • UL / cUL508
• 3 contactor bypass with TEST mode • Hardware options:
• Auto / Manual bypass versions - Input reactor (3 or 5%)
• Bi-directional Coasting Motor Restart (anti-windmill) - Damper Vane Actuator relay
• Adjustable Class 20 overload relay - Extended Analog Output
• Programming / display keypad and speed setting dial - Hand-Off-Auto with potentiometer
• DC link choke as standard - Alphanumeric Keypad
• Choice of fused disconnect, non-fused disconnect or • Extended communications:
circuit breaker - Metasys N2
• Control transformer, fused primary and secondary - LonWorks
• Terminal blocks for control connections - Siemens FLN (P1)
• RS-485 Modbus RTU and BACnet MS/TP as standard - EtherNet/IP
• Complete standard Mitsubishi testing - BACnet/IP
• 2 year warranty - Modbus TCP/IP
• Mitsubishi ‘Energy Oprimization’ System - PROFINET
• 5 second Power Dip Ride Through • For NEMA 3R systems:
• 2 independent PID loops - Thermostatic cabinet control
• AutoCAD documentation package - Screened entrance for cooling air
• Instruction manuals for VFD and controller

Part Number Structure - Sized up to 40HP (208-240V) and 75HP (380 - 480V)

F1

Symbol Horsepower Rating Symbol Choke/Reactor Type Symbol Options


001 - 250 1 - 250 HP* D DC Link Choke Damper vane actuator
S1
relay fitted
* Maximum HP varies according to voltage and 3 3% Input Reactor (option)
enclosure type. Hand-Off-Auto switch with
S2
5 5% Input Reactor (option) potentiometer
Symbol Input Voltage S3 Extended analog output
2V 208 - 240V Symbol Bypass Type S4 Alphanumeric keypad

4V 380 - 480V B Manual 3 contactor bypass S5 Drive trip/run relay (non-bypass only)

N Non bypass S6 100kA SCCR rating (fused types)


Symbol Disconnect Type Up to 3 options may be selected.
A Auto bypass
C UL 489 Circuit Breaker
Symbol Network Type
D Non-Fused Disconnect (option) Enhanced RS-485 capability
F Fused Disconnect (200kA) (option) Siemens FLN, Metasys N2
RS
(Modbus RTU and BACnet,
MS/TP are standard.)
Symbol Enclosure Type
LN Lonworks
1 NEMA 1
Ethernet Communications
2 NEMA 12 ET (Ethernet IP, Modbus TCP/IP,
3 NEMA 3R BACnet IP, ProfiNET)
Select one option if required.

444
FR-F700 Based VFD Complete Bypass System - NEMA 1
Standard Product with
Circuit Breaker & 3 Contactor 208V Based VFD System Panel 460V Based VFD System Panel
Bypass VFD System Size Size
HP KW Model Number Stk. Item Amps Model Number Stk. Item Amps
1 0.75 F1C2V001BD - 4.2 N1A F1C4V001BD - 2.1 N1A
2 1.5 F1C2V002BD S 7 N1A F1C4V002BD S 3.5 N1A
3 2.2 F1C2V003BD S 9.6 N1A F1C4V003BD S 4.8 N1A
5 3.7 F1C2V005BD S 15.2 N1A F1C4V005BD S 7.6 N1A
7.5 5.5 F1C2V007BD S 23 N1B F1C4V007BD S 11.5 N1A
10 7.5 F1C2V010BD S 31 N1B F1C4V010BD S 16 N1A
15 11 F1C2V015BD S 45 N1B F1C4V015BD S 23 N1B
20 15 F1C2V020BD S 58 N1B F1C4V020BD S 29 N1B
25 18.5 F1C2V025BD S 70 N1C F1C4V025BD S 35 N1C
30 22 F1C2V030BD S 85 N1C F1C4V030BD S 43 N1C
40 30 F1C2V040BD S 114 N1D F1C4V040BD S 57 N1C
50 - - - - - F1C4V050BD S 70 N1D
60 - - - - - F1C4V060BD S 85 N1D
75 - - - - - F1C4V075BD S 106 N1D

Panel Lbs H (in) W (in) D (in)


N1A 70 32.3 12.5 10.8
N1B 150 50 16.5 13
N1C 200 60.3 25.5 13.8
N1D 285 65.7 25.5 15.3
Floor
850 78 47.25 20
Mount

FR-F700 Based VFD Complete Bypass System - NEMA 12


Standard Product with
Circuit Breaker and 3 Contactor 208V Based VFD System Panel 460V Based VFD System Panel
Bypass VFD System Size Size
HP KW Model Number Stk. Item Amps Model Number Stk. Item Amps
1 1 F2C2V001BD - 4.2 N12A F2C4V001BD - 2.1 N12A
2 1.5 F2C2V002BD - 7 N12A F2C4V002BD - 3.5 N12A
3 2.2 F2C2V003BD - 9.6 N12A F2C4V003BD - 4.8 N12A
5 3.7 F2C2V005BD - 15.2 N12A F2C4V005BD - 7.6 N12A
7.5 5.5 F2C2V007BD - 23 N12A F2C4V007BD - 11.5 N12A
10 7.5 F2C2V010BD - 31 N12B F2C4V010BD - 16 N12B
15 11 F2C2V015BD - 45 N12B F2C4V015BD - 23 N12B
20 15 F2C2V020BD - 58 N12B F2C4V020BD - 29 N12C
25 18.5 F2C2V025BD - 70 N12C F2C4V025BD - 35 N12C
30 22 F2C2V030BD - 85 N12C F2C4V030BD - 43 N12C
40 30 F2C2V040BD - 114 N12C F2C4V040BD - 57 N12C
50 37 F2C2V050BD - 140 N12D F2C4V050BD - 70 N12D
60 45 F2C2V060BD - 170 N12F F2C4V060BD - 85 N12D
75 55 F2C2V075BD - 212 N12F F2C4V075BD - 106 N12E
100 75 F2C2V100BD - 288 N12F F2C4V100BD - 144 N12E
125 - - - - - F2C4V125BD - 180 N12E
150 - - - - - F2C4V150BD - 216 N12F
200 - - - - - F2C4V200BD - 260 N12F
250 - - - - - F2C4V250BD - 325 N12F

Panel Lbs H (in) W (in) D (in) Type


N12A 88 29 22 10 Wall
N12B 121 31 24 11.5 Wall
N12C 174 38 32 12 Wall
N12D 394 49 36 18 Wall
N12E 562 60 36 24 Wall
N12F 779 77 32 29 Floor

Mitsubishi Electric Automation | Variable Frequency Drives 445


n VARIABLE FREQUENCY DRIVES
FR-F700 Based VFD Complete Bypass System - NEMA 3R
Standard Product with
Circuit Breaker & 3 Contactor 208V Based VFD System 460V Based VFD System
Bypass VFD System Panel Size Panel Size

HP KW Model Number Stk. Item Amps Model Number Stk. Item Amps
1 1 F3C2V001BD - 4.2 N3A F3C4V001BD - 2.1 N3A
2 1.5 F3C2V002BD - 7 N3A F3C4V002BD - 3.5 N3A
3 2.2 F3C2V003BD - 9.6 N3A F3C4V003BD - 4.8 N3A
5 3.7 F3C2V005BD - 15.2 N3A F3C4V005BD - 7.6 N3A
7.5 5.5 F3C2V007BD - 23 N3A F3C4V007BD - 11.5 N3A
10 7.5 F3C2V010BD - 31 N3B F3C4V010BD - 16 N3B
15 11 F3C2V015BD - 45 N3C F3C4V015BD - 23 N3B
20 15 F3C2V020BD - 58 N3C F3C4V020BD - 29 N3C
25 18.5 F3C2V025BD - 70 N3D F3C4V025BD - 35 N3C
30 22 F3C2V030BD - 85 N3D F3C4V030BD - 43 N3C
40 30 F3C2V040BD - 114 N3D F3C4V040BD - 57 N3C
50 37 F3C2V050BD - 140 N3E F3C4V050BD - 70 N3D
60 45 - - - - F3C4V060BD - 85 N3D
75 55 - - - - F3C4V075BD - 106 N3E
100 75 - - - - F3C4V100BD - 144 N3E
125 90 - - - - F3C4V125BD - 180 N3E

Panel Lbs H (in) W (in) D (in) Type


N3A 88 29 22 10 Wall
N3B 121 31 24 11.5 Wall
N3C 174 38 32 12 Wall
N3D 394 49 36 18 Wall
N3E 562 60 36 24 Wall

446
C1-D Enclosed Drives for Commercial Pump and Fan Control – NEMA 1
C 1 -D F V

Symbol Input Voltage Symbol Bypass Symbol DC Link


2 208 - 230V B Bypass Type D DC Link
4 460 - 480V N Non-Bypass Type None No DC Link

Symbol Enclosure Type Symbol Horsepower Rating

NEMA 1, UL-1 01 1HP


C1-DF
Fused Disconnect 02 2HP
03 3HP
05 5HP
07 7.5HP
10 10HP
15 15HP
20 20HP From Power Supply
Standard Features
• FR-D700 VFD with PWM control and carrier frequency up to 14.5kHz
• VFD parameter unit for keypad entry and display
• Emergency stop circuit with provision for N/C contacts
• Internal control transformer
• Panel mounted master control switch for bypass changeover (*1)
• Conduit knock-out points for power entry and exit – bottom of enclosure
• DC link reactor to improve power quality VFD
• All internal wiring is individually marked, numbered and clearly labelled
• 5 year VFD warranty, 2 year fully inclusive warranty for entire controller

To Motor

Bypass System Non-Bypass System


Thermal
Disconnect DC Link Disconnect DC Link
Size (HP) Drive Type AIC Overload Size (HP) Drive Type AIC
Fuse Rating Reactor Fuse Rating Reactor (*1)
Rating
208-230V 208-230V
1 C1-DF2V01BD 6A 200kA 4A 12mH 1.7 - 2.5A 1 C1-DF2V01BN 6A 200kA 4A 12mH
2 C1-DF2V02BD 10A 200kA 12A 2.1mH 5.2 - 8.0A 2 C1-DF2V02BN 10A 200kA 12A 2.1mH
3 C1-DF2V03BD 15A 200kA 12A 4mH 9.0 - 13.0A 3 C1-DF2V03BN 15A 200kA 12A 4mH
5 C1-DF2V05BD 30A 200kA 18A 2.75mH 12.0 - 18.0A 5 C1-DF2V05BN 30A 200kA 18A 2.75mH
7.5 C1-DF2V07BD 40A 200kA 32A 0.85mH 18-26A 7.5 C1-DF2V07BN 40A 200kA 32A 0.85mH
10 C1-DF2V10BD 40A 200kA 40A 0.75mH 24-34A 10 C1-DF2V10BN 40A 200kA 40A 0.75mH
15 C1-DF2V15BD 60A 200kA 62A 0.32mH 43-65A 15 C1-DF2V15BN 60A 200kA 62A 0.32mH
460-480V 460-480V
1 C1-DF4V01BD 2A 200kA 2A 50mH 1.7 - 2.5A 1 C1-DF4V01BN 2A 200kA 2A 50mH
2 C1-DF4V02BD 5A 200kA 4A 12mH 2.8 - 4.4A 2 C1-DF4V02BN 5A 200kA 4A 12mH
3 C1-DF4V03BD 6A 200kA 9A 7.5mH 4.0 - 6.0A 3 C1-DF4V03BN 6A 200kA 9A 7.5mH
5 C1-DF4V05BD 15A 200kA 9A 7.5mH 5.2 - 8.0A 5 C1-DF4V05BN 15A 200kA 9A 7.5mH
7.5 C1-DF4V07BD 15A 200kA 18A 3.75mH 9.0 - 13.0A 7.5 C1-DF4V07BN 15A 200kA 18A 3.75mH
10 C1-DF4V10BD 30A 200kA 18A 2.75mH 12.0 - 18.0A 10 C1-DF4V10BN 30A 200kA 18A 2.75mH
15 C1-DF4V15BD 40A 200kA 25A 1.75 mH 18-26A 15 C1-DF4V15BN 40A 200kA 25A 1.75 mH
20 C1-DF4V20BD 40A 200kA 32A 1.62 mH 24-34A 20 C1-DF4V20BN 40A 200kA 32A 1.62 mH
Note:
1. When supplied.

Mitsubishi Electric Automation | Variable Frequency Drives 447


n VARIABLE FREQUENCY DRIVES
F3IP Agricultural Pump Drive Solutions
A3IP is a dedicated controller for agricultural irrigation systems allowing the intelligent control and scheduling of multiple pumps. Available in
sizes up to 150HP (230V) and 600HP (480V), units are supplied in NEMA 3R wall-mounted cabinets. A door-mounted display screen allows
simple operation and display of critical information.
Part Number Structure
F3IP

Symbol Input Voltage Symbol Choke/Reactor Type Symbol Options


2V 208 - 240V D DC Link Choke S4 Alphanumeric keypad
4V 380 - 480V 3 3% Input Reactor (option)
5 5% Input Reactor (option) Symbol Network Type
Symbol Enclosure Type Enhanced RS-485 Capability
Mitsubishi NEMA 3R Symbol Horsepower Rating (BACnet, Siemens FLN,
RS
A3IP Irrigation Pump Drive A700-NA5 Metasys N2)
001 1HP Modbus RTU is standard
PLC
002 2HP LN Lonworks
003 3HP Ethernet Communications
ET (Ethernet IP, Modbus TCP/IP,
005 5HP
BACnet IP, ProfiNET)
007 7.5HP
Select one option if required.
110 10HP
015 15HP
020 20HP
025 25HP
030 30HP
(motor frame sizes up to 600HP)
F3IP Agricultural Pump Drive Solutions - 600 600HP
NEMA 3R
Standard Product with
Circuit Breaker & 3 Contactor 208V Based VFD System Panel 460V Based VFD System Panel
Bypass VFD System Size Size
HP KW Model Number Stk. Item Amps Model Number Stk. Item Amps
1 1 F3IPC2V001ND - 4.2 N3A F3IPC4V001ND - 2.1 N3A
2 1.5 F3IPC2V002ND - 7 N3A F3IPC4V002ND - 3.5 N3A
3 2.2 F3IPC2V003ND - 9.6 N3A F3IPC4V003ND - 4.8 N3A
5 3.7 F3IPC2V005ND - 15.2 N3A F3IPC4V005ND - 7.6 N3A
7.5 5.5 F3IPC2V007ND - 23 N3A F3IPC4V007ND - 11.5 N3A
10 7.5 F3IPC2V010ND - 31 N3B F3IPC4V010ND - 16 N3B
15 11 F3IPC2V015ND - 45 N3B F3IPC4V015ND - 23 N3B
20 15 F3IPC2V020ND - 58 N3B F3IPC4V020ND - 29 N3B
25 18.5 F3IPC2V025ND - 70 N3C F3IPC4V025ND - 35 N3B
30 22 F3IPC2V030ND - 85 N3C F3IPC4V030ND - 43 N3C
40 30 F3IPC2V040ND - 114 N3C F3IPC4V040ND - 57 N3C
50 37 F3IPC2V050ND - 140 N3D F3IPC4V050ND - 70 N3D
60 45 F3IPC2V060ND - 170 N3D F3IPC4V060ND - 85 N3D
75 55 F3IPC2V075ND - 212 N3D F3IPC4V075ND - 106 N3D
100 75 F3IPC2V100ND - 288 N3E F3IPC4V100ND - 144 N3D
125 93 F3IPC2V125ND - 346 N3E F3IPC4V125ND - 180 N3D
150 112 F3IPC2V150ND - 432 N3E F3IPC4V150ND - 216 N3E
200 149 - - - - F3IPC4V200ND - 260 N3E
250 187 - - - - F3IPC4V250ND - 325 N3E
300 225 - - - - F3IPC4V300ND - 361 N3F
350 261 - - - - F3IPC4V350ND - 432 N3F
400 299 - - - - F3IPC4V400ND - 481 N3F
450 336 - - - - F3IPC4V450ND - 547 N3G
500 373 - - - - F3IPC4V500ND - 610 N3G
550 410 - - - - F3IPC4V550ND - 683 N3G
650 485 - - - - F3IPC4V650ND - 770 N3G
700 522 - - - - F3IPC4V700ND - 866 N3H

Panel Lbs H (in) W (in) D (in) Type


N3A 88 29 22 10 Wall
N3B 121 31 24 11.5 Wall
N3C 174 38 32 12 Wall
N3D 394 49 36 18 Wall
N3E 562 60 36 24 Wall
N3F 779 72 32 24 Floor
N3G 1025 84 39 24 Floor
N3H 1225 90 48 24 Floor

448
F8 Type 18 Pulse Controllers
F8 controllers are intended for the control of pumps and fans. 18 pulse technology is used to ensure that the quality of the site power supply
is maintained. These 460VAC Drives (10-800 HP) are LD rated at 120% overload for one minute, available in both bypass and non-bypass
configurations in NEMA 12 Ventilated Floor mounted cabinets. UL508A rated to meet IEEE519-1992 standards.
Base System Includes:
• NEMA 12 ventilated construction • RS-485, Modbus RTU Communication standard, EMI / RFI
• Standard Hoffman ANSI 61 gray paint filter standard
• 18 Pulse Clean Power Design Technology • AutoCAD documentation packet
• 3 contactor bypass with TEST mode • Instruction manuals for VFD and controller
• Choice of bypass or non-bypass units • UL / cUL 508A
• Catch a spinning load / windmill start activated • Hardware options: Damper vane actuator relay, extended analog
output, hand-off autoswitch with potentiometer, PU07 keypad /
• Adjustable overload relay, class 20 equivalent display door mounted
• Programming / display keypad and speed setting dial • Communications Options: BACnet® MS/TP, Metasys® N2,
• Choice of fused disconnect or circuit breaker (standard) LonWorks®, Siemens® FLN(P1), EtherNet/IP™, BACnet® IP,
• Control transformer, fused primary and secondary Modbus® TCP/IP, PROFINET
• Terminal blocks for control connections • 2 year warranty

Part Number Structure

F8 4V

Symbol Horsepower Rating Symbol Network Type Symbol Options


010 10HP Enhanced RS-485 capability Damper vane actuator
S1
(BACnet, Siemens FLN, relay fitted
015 15HP RS
Metasys N2) Hand Off autoswitch with
Modbus RTU is standard S2
020 20HP potentiometer
025 25HP LN Lonworks S3 Extended analog output

030 30HP Ethernet Communications S4 Alphanumeric keypad


ET (Ethernet IP, Modbus TCP/IP, S5 Drive trip/run relay (non-bypass only)
040 40HP BACnet IP, ProfiNET)
(Motor frame sizes up to 800HP) Up to 3 options may be selected.
Select one option if required.
800 800HP
Symbol Bypass Type
B Manual 3 contactor bypass
Symbol Input Voltage
N 3 contactor non-bypass (option)
4V 380 - 480V

Symbol Disconnect Type


C UL 489 circuit breaker
F Fused disconnect (100kA) (option)

Symbol Enclosure Type


8 18 Pulse NEMA 12V

For further information, please refer to our website, www.MEAU.com

Mitsubishi Electric Automation | Variable Frequency Drives 449


n VARIABLE FREQUENCY DRIVES
Type CK Conduit Mounting Kits
The CK range of Type 1 Conduit Mounting Kits is intended for use with D700 and E700 Series VFDs. This kit allows the drive to be
mounted outside of a normal enclosure.

Main Features • Units available from stock


• Available for all 3 phase D700 and E700 VFDs • 7 frame sizes
• Provides conduit holes on both sides and the • Drive mounting screws provided
bottom • Ample box area for easy wiring with generous wire
• Knockout conduits provided bend radius
• Supplied as a kit to be installed in the field • Suitable for 208/230V and 460/480V drives

Conduit Kit Selection Chart


D700 Series VFD Model Number E700 Series VFD Model Number
FR-D720-008-NA FR-E720-008
FR-D720-025-NA FR-E720-015
FR-D720-042-NA CKDE1 FR-E720-030
CKDE1
FR-D720-070-NA FR-E720-050
FR-D720-100-NA FR-E720-080
FR-D720-165-NA CKDE3 FR-E720-110
FR-D720-238-NA FR-E720-175 CKDE3
CKDE4
FR-D720-318-NA FR-E720-240
FR-D740-012-NA FR-E720-330
CKDE5
FR-D740-022-NA FR-E720-470
FR-D740-036-NA CKDE1 FR-E720-600
FR-D740-050-NA FR-E740-016
FR-D740-080-NA FR-E740-026
FR-D740-120-NA FR-E740-040 CKDE2
CKDE4
FR-D740-160-NA FR-E740-060
FR-E740-095 * Drive not included
FR-E740-120
CKDE4
FR-E740-170
FR-E740-230
CKDE5
FR-E740-300

Type G General Purpose Controllers


For D700 and E700 VFD – NEMA 12 or NEMA 3R Construction
Type G controllers are general purpose
G
packaged drives suitable for a wide range of
applications where a remote mounted VFD is
required. Any Mitsubishi VFD up to 700HP can
be configured into a type G package with either
a NEMA 12 or NEMA 3R enclosure.
Symbol Input/Output Voltage Symbol Choke/Reactor Type Symbol Options
2V 3/60/208 (230/240)VAC D DC Link Choke S4 Alphanumeric keypad
Base System Includes: 4V 3/60/460 (480)VAC 3 3% Input Reactor (option)
• RAL 7035 light gray paint 5 5% Input Reactor (option)

• Bottom mounted inlet and exhaust vents Symbol Input Voltage


C Circuit Breaker Symbol Horsepower Rating
• D700 controller with LCD keypad / display F Fused Disconnect 001 1HP

• Rated 150% overload for one minute, 002 2HP


003
200% for 3 seconds Symbol Input Voltage 3HP
2 NEMA 12 Ventilated 005 5HP
• DC Link Choke included as standard 3 NEMA 3R 007 7.5HP

• Thermostatically controlled space heater Disconnect Type


010 10HP
Symbol
• Choice of fused disconnect or UL 489 D D700 Drive
circuit breaker (standard) E E700 Drive

• Modbus RTU Communication standard Symbol Enclosure Type

• AutoCAD documentation package G General Purpose

• VFD instruction manual


• UL / cUL 508
• Hardware options: Input reactor, (3% or
5%), door mounted PU07 keypad / display
• 2 year warranty

450
For A700 and F700 VFD – NEMA 12 or NEMA 3R Construction
Base System Includes: G
• RAL 7035 light gray paint
• Bottom mounted inlet and exhaust vents
• F700 controller with LCD keypad / display
• LD Rated 120% overload for one minute Symbol Input/Output Voltage Symbol Choke/Reactor Type Symbol Options
2V 3/60/208 (230/240)VAC D DC Link Choke
• DC Link Choke included as standard 4V 3/60/460 (480)VAC 3 3% Input Reactor (option)
S4 Alphanumeric keypad

• Choice of fused disconnect or UL 489 circuit 5 5% Input Reactor (option) Symbol Network Type

breaker (standard) Symbol Input Voltage


Symbol Horsepower Rating
LN Lonworks (FR-A7NL)
C Circuit Breaker
ET Ethernet (FR-A7NE)
• RS-485, Modbus RTU Communication F Fused Disconnect 001 1HP
RS RS485 (FR-A7N-XLT)
standard, EMI/RFI filter standard 002 2HP
CC CC-Link (FR-A7NC)
Symbol Input Voltage 003 3HP
• AutoCAD documentation package 2 NEMA 12 Ventilated 005 5HP
DN DeviceNet (FR-A7ND)
DP Profibus (FR-A7NP)
• Instruction manuals for VFD and controller 3 NEMA 3R 007 7.5HP
101 10HP
• UL / cUL 508 Symbol Disconnect Type
015 15HP
A A700 Drive
• Hardware options: Input reactor, (3% or F F700 Drive
020 20HP

5%), PU07 keypad / display 025 25HP


Symbol Enclosure Type 030 30HP
• Communications Options: BACnet® MS/ G General Purpose
(motor frame sizes up to 700HP)

TP, Metasys® N2, LonWorks®, Siemens® 700 700HP

FLN(P1), EtherNet/IP™, BACnet® IP,


Modbus® TCP/IP, CC-Link®, DeviceNet™,
PROFIBUS-DP
• 2 year warranty

Mitsubishi Electric Automation | Variable Frequency Drives 451


n VARIABLE FREQUENCY DRIVES
General Options
Recommended Peripheral Devices For VFDs
Input / Output Reactors (*1) DC Link Choke Input Circuit Breaker Passive Harmonic Sine Wave
Motor HP Input Contactor
3% 5% (*2) (UL489) Filter (*3) Output Filter (*3)
208-230V
1/4 MRL-00201 MRL-00202 DCA000204 NF50-SVFU3P5A S-N10 - -
1/2 MRL-00205 MRL-00201 DCA000402 NF50-SVFU3P5A S-N10 - -
1 MRL-00401 MRL-00402 DCA000902 NF50-SVFU3P10A S-N10 - -
2 MRL-00801 MRL-00802 DCA000802 NF50-SVFU3P15A S-N10 - -
3 MRL-01201 MRL-01202 DCA001802 NF50-SVFU3P20A S-N10 - -
5 MRL-01801 MRL-01802 DCA001802 NF50-SVFU3P30A S-N20 - -
7.5 MRL-02501 MRL-02502 DCA003201 NF50-SVFU3P50A S-N20 - -
10 MRL-03501 MRL-03502 DCA004002 NF125-SVU3P60A S-N25 - -
15 MRL-04501 MRL-04502 DCA005001 NF125-SVU3P75A S-N35 - -
20 MRL-05501 MRL-05502 DCA008002 NF125-SVU3P125A S-N50 - -
25 MRL-08001 MRL-08002 DCA011003 NF250-SVU3P150A S-N65 - -
30 MRL-08001 MRL-08002 DCA011003 NF250-SVU3P175A S-N80 - -
40 MRL-10001 MRL-10002 DCA012502 NF250-SVU3P225A S-N95 - -
50 MRL-13001 MRL-13002 DCA020002 NF250-SVU3P250A S-N150 - -
60 MRL-16001 MRL-16002 DCA020002 NF-SKW3P300A S-N180 - -
75 MRL-20001B14 MRL-20002B14 Standard NF-SKW3P400A S-N200 - -
100 MRL-25001B14 MRL-25002B14 Standard NF-SKW3P400A S-N300 - -
125 MRL-32001B14 MRL-32002B14 Standard NF-SKW3P400A S-N300 - -
150 MRL-40001B14 MRL-40002B14 Standard NF-SKW3P400A S-N300 - -
200 MRL-50001 MRL-50002 Standard NF-SLW3P500A S-N400 - -
460-480V
1/2 MRL-00201 MRL-00103 DCA000204 NF100-HRU3P5A S-N10 -
1 MRL-00201 MRL-00202 DCA000204 NF100-HRU3P5A S-N10 - SWAP0009D
2 MRL-00402 MRL-00403 DCA000402 NF100-HRU3P10A S-N10 - SWAP0009D
3 MRL-00402 MRL-00403 DCA000903 NF100-HRU3P10A S-N10 MDP0006D SWAP0009D
5 MRL-00802 MRL-00803 DCA000903 NF125-SVU3P20A S-N10 MDP0008D SWAP0009D
7.5 MRL-01202 MRL-01203 DCA001804 NF125-SVU3P30A S-N20 MDP0011D SWAP0012D
10 MRL-01802 MRL-01803 DCA001803 NF125-SVU3P30A S-N20 MDP0014D SWAP0017D
15 MRL-02502 MRL-04502 DCA002503 NF125-SVU3P50A S-N20 MDP0021D SWAP0022D
20 MRL-03502 MRL-05502 DCA003202 NF125-SVU3P60A S-N25 MDP0027D SWAP0027D
25 MRL-03502 MRL-08002 DCA004003 NF125-SVU3P75A S-N25 MDP0034D SWAP0035D
30 MRL-04502 MRL-08002 DCA005004 NF125-SVU3P100A S-N35 MDP0044D SWAP0045D
40 MRL-05502 MRL-10002 DCA008005 NF125-SVU3P125A S-N50 MDP0052D SWAP0055D
50 MRL-08002 MRL-13002 DCA008005 NF250-SVU3P150A S-N65 MDP0066D SWAP0065D
60 MRL-08002 MRL-16002 DCA009202 NF250-SVU3P175A S-N80 MDP0083D SWAP0080D
75 MRL-10002 MRL-20002B14 Standard NF250-SVU3P200A S-N80 MDP0103D SWAP0110D
100 MRL-13002 MRL-13003 Standard NF250-SVU3P225A S-N95 MDP0128D SWAP0130D
125 MRL-16002 MRL-16003 Standard NF250-SVU3P225A S-N150 MDP0165D SWAP0160D
150 MRL-20002B14 MRL-20003B14 Standard NF250-SVU3P225A S-N180 MDP0208D SWAP0200D
200 MRL-25002B14 MRL-25003B14 Standard NF-SKW3P400A S-N220 MDP0240D SWAP0250D
250 MRL-32002B14 MRL-32003B14 Standard NF-SKW3P400A S-N300 MDP0320D SWAP0350D
300 MRL-40002B14 MRL-40003B14 Standard NF-SKW3P400A S-N300 MDP0403D SWAP0365D
350 MRL-50002 MRL-50003 Standard NF-SLW3P500A S-N400 MDP0482D SWAP0415D
400 MRL-50002 MRL-50003 Standard NF-SLW3P600A S-N600 MDP0482D SWAP0515D
450 MRL-60002 MRL-60003 Standard NF-SLW3P600A S-N600 MDP0636D SWAP0515D
500 MRL-60002 MRL-60003 Standard - S-N600 MDP0636D SWAP0600D
550 MRL-75002 MRL-75003 Standard - S-N600 MDP0786D SWAP0720D
600 MRL-75002 MRL-75003 Standard - S-N800 MDP0786D -
700 MRL-85002 MRL-85003 Standard - - - -
800 MRL-100002 MRL-100013 Standard - - - -
600V
1 MRL-00202 MRL-00203 DCA000204 - S-N10 - -
3 MRL-00403 MRL-00404 DCA000904 NF125-HVU3P15A S-N20 - -
5 MRL-00803 MRL-00804 DCA000904 NF125-HVU3P20A S-N20 - -
10 MRL-01202 MRL-01203 DCA001803 NF125-HVU3P30A S-N20 - -
20 MRL-02502 MRL-02503 DCA003203 NF125-HVU3P60A S-N25 - -
30 MRL-03502 MRL-03503 DCA004003 NF125-HVU3P100A S-N25 - -
50 MRL-05502 MRL-05503 DCA008005 NF125-HVU3P125A S-N50 - -
75 MRL-08002 MRL-08003 DCA009203 NF250-HVU3P175A S-N65 - -
100 MRL-10002 MRL-10003 Standard NF250-HVU3P175A S-N65 - -
125 MRL-13002 MRL-13003 Standard NF250-HVU3P225A S-N80 - -
150 MRL-16002 MRL-16003 Standard NF250-HVU3P250A S-N125 - -
200 MRL-20002B14 MRL-20003B14 Standard NF-SKW3P350A S-N150 - -
300 MRL-32002B14 MRL-32013B14 Standard NF-SKW3P400A S-N180 - -
350 MRL-40002B14 MRL-40013B14 Standard NF-SLW3P600A S-N300 - -
450 MRL-50002 MRL-40013B14 Standard NF-SLW3P600A S-N400 - -
550 MRL-60002 MRL-60003 Standard - S-N600 - -
700 MRL-75002 MRL-75003 Standard - S-N600 - -
Notes:
1. Part numbers for input reactors are for OPEN types. Change the second from last digit to a '1' for NEMA 1 types (e.g. MRL-00201 becomes MRL-00211)
2. DC Link chokes are OPEN type and at least 3% inductance
3. Part numbers for passive and sine wave filters are for OPEN types. Designed to limit THDi to 5%. Change the P to a G for NEMA 2 enclosures (e.g. MDP0006D becomes MDG006D,
SWAP0009D becomes SWAG0009D)

452
Line / Load Reactor Electrical Data
Model Number Watts Loss Wire Range (AWG) Terminal Torque (in / lbs) Ind. mH Fund Amps Max Amps
MRL-00201 8 22 14 4.5 12 2 3
MRL-00202 12 22 14 4.5 20 2 3
MRL-00203 16 22 14 4.5 32 2 3
MRL-00204 11 22 14 4.5 6 2 3
MRL-00401 15 22 14 4.5 3 4 6
MRL-00402 20 22 14 4.5 6.5 4 6
MRL-00403 20 22 14 4.5 9 4 6
MRL-00404 21 22 14 4.5 12 4 6
MRL-00801 20 22 14 4.5 1.5 8 12
MRL-00802 29 22 14 4.5 3 8 12
MRL-00803 26 22 14 4.5 5 8 12
MRL-00804 28 22 14 4.5 7.5 8 12
MRL-01201 26 22 5 16 1.25 12 18
MRL-01202 31 22 5 16 2.5 12 18
MRL-01203 41 22 5 16 4.2 12 18
MRL-01801 36 22 5 16 0.8 18 27
MRL-01802 43 22 5 16 1.5 18 27
MRL-01803 43 22 5 16 2.5 18 27
MRL-02501 48 22 5 16 0.5 25 37.5
MRL-02502 52 22 5 16 1.2 25 37.5
MRL-02503 61 22 5 16 1.8 25 37.5
MRL-03501 49 22 5 16 0.4 35 52.5
MRL-03502 54 22 5 16 0.8 35 52.5
MRL-03503 54 18 4 20 1.2 35 52.5
MRL-04501 54 18 4 20 0.3 45 67.5
MRL-04502 62 18 4 20 0.7 45 67.5
MRL-04503 65 18 4 20 1.2 45 67.5
MRL-05501 64 6 0 6-4(45) & 2-0(50) 0.25 55 82.5
MRL-05502 67 6 0 6-4(45) & 2-0(50) 0.5 55 82.5
MRL-05503 71 6 0 6-4(45) & 2-0(50) 0.85 55 82.5
MRL-08001 82 6 0 6-4(45) & 2-0(50) 0.2 80 120
MRL-08002 86 6 0 6-4(45) & 2-0(50) 0.4 80 120
MRL-08003 96 6 0 6-4(45) & 2-0(50) 0.7 80 120
MRL-10001 94 6 0 6-4(45) & 2-0(50) 0.15 100 150
MRL-10002 84 6 0 6-4(45) & 2-0(50) 0.3 100 150
MRL-10003 108 6 0 6-4(45) & 2-0(50) 0.45 100 150
MRL-13001 108 2 0000 150 0.1 130 195
MRL-13002 180 2 0000 150 0.2 130 195
MRL-13003 128 2 0000 150 0.3 130 195
MRL-16001 116 2 0000 150 0.075 160 240
MRL-16002 149 2 0000 150 0.15 160 240
MRL-16003 138 2 0000 150 0.23 160 240
MRL-20001B14 124 Copper tab Not Applicable 0.055 200 300
MRL-20002B14 168 Copper tab Not Applicable 0.11 200 300
MRL-20003B14 146 Copper tab Not Applicable 0.185 200 300
MRL-25001B14 154 Copper tab Not Applicable 0.045 250 375
MRL-25002B14 231 Copper tab Not Applicable 0.09 250 375
MRL-25003B14 219 Copper tab Not Applicable 0.15 250 375
MRL-32001B14 224 Copper tab Not Applicable 0.04 320 480
MRL-32002B14 264 Copper tab Not Applicable 0.075 320 480
MRL-32003B14 351 Copper tab Not Applicable 0.125 320 480
MRL-40001B14 231 Copper tab Not Applicable 0.03 400 600
MRL-40002B14 333 Copper tab Not Applicable 0.06 400 600
MRL-40003B14 293 Copper tab Not Applicable 0.105 400 600
MRL-50001 266 Copper tab Not Applicable 0.025 500 750
MRL-50002 340 Copper tab Not Applicable 0.05 500 750
MRL-50003 422 Copper tab Not Applicable 0.085 500 750
MRL-60001 307 Copper tab Not Applicable 0.02 600 900
MRL-60002 414 Copper tab Not Applicable 0.04 600 900
MRL-60003 406 Copper tab Not Applicable 0.065 600 900
MRL-75001 427 Copper tab Not Applicable 0.015 750 1125
MRL-75002 630 Copper tab Not Applicable 0.029 750 1125
MRL-75003 552 Copper tab Not Applicable 0.048 750 1125
MRL-85001 798 Copper tab Not Applicable 0.015 850 1063
MRL-85002 930 Copper tab Not Applicable 0.027 850 1063
MRL-85003 1133 Copper tab Not Applicable 0.042 850 1063
MRL-90001 860 Copper tab Not Applicable 0.013 900 1125
MRL-90002 1020 Copper tab Not Applicable 0.025 900 1125
MRL-90003 1365 Copper tab Not Applicable 0.04 900 1125
MRL-100001 940 Copper tab Not Applicable 0.011 1000 1250
MRL-100002 1090 Copper tab Not Applicable 0.022 1000 1250
MRL-100003 1500 Copper tab Not Applicable 0.038 1000 1250
For additional information visit http://www.mtecorp.com/lineload.html

Mitsubishi Electric Automation | Variable Frequency Drives 453


n VARIABLE FREQUENCY DRIVES
DC Choke Electrical Data
Model No. DC Amps mH Watts Lug Size Torque Unit Weight (lbs)
DCA000204 2 50 5 22-14 4.5 2
DCA000402 4 12 5 22-14 4.5 2
DCA000403 4 15 6 22-14 4.5 2
DCA000404 4 25 9 18-4 20 4
DCA000902 9 3.22 7 22-14 4.5 2
DCA000903 9 7.5 11 18-4 20 4
DCA000904 9 11.5 16 18-4 20 7
DCA001201 12 1 5 22-14 4.5 1
DCA001202 12 1 7 18-4 20 2
DCA001203 12 4 11 18-4 20 4
DCA001204 12 6 14 18-4 20 7
DCA001801 18 0.65 5 18-4 20 2
DCA001802 18 1.375 9 18-4 20 4
DCA001803 18 2.75 16 18-4 20 7
DCA001804 18 3.75 17 18-4 20 8
DCA001805 18 6 20 18-4 20 13
DCA002503 25 1.275 13 18-4 20 7
DCA002504 25 1.75 13 18-4 20 5
DCA002505 25 4 16 18-4 20 13
DCA003201 32 0.85 11 18-4 20 5
DCA003202 32 1.62 14 18-4 20 10
DCA003203 32 2.68 21 18-4 20 14
DCA004001 40 0.5 14 18-4 20 5
DCA004002 40 0.75 15 18-4 20 7
DCA004003 40 1 17 18-4 20 8
DCA004004 40 2 29 18-4 20 21
DCA005001 50 0.625 18 18-4 20 8
DCA005003 50 1.35 21 18-4 20 15
DCA005004 50 2 30 6-0 6-4(45) &2-0 25
DCA006201 62 0.32 17 6-0 6-4(45) &2-0 8
DCA006202 62 0.61 20 6-0 6-4(45) &2-0 14
DCA008002 80 0.4 25 6-0 6-4(45) & 2-0(50) 14
DCA008005 80 1.25 25 6-0 6-4(45) & 2-0(50) 35
DCA009201 92 0.2 19 6-0 6-4(45) & 2-0(50) 10
DCA009202 92 0.6 34 6-0 6-4(45) & 2-0(50) 23
DCA009203 92 1 48 6-0 6-4(45) & 2-0(50) 32
DCA011002 110 0.3 38 6-0 6-4(45) & 2-0(50) 22
DCA011003 110 0.45 45 6-0 6-4(45) & 2-0(50) 22
DCA012502 125 0.22 27 6-0 6-4(45) & 2-0(50) 23
DCA015002 150 0.22 36 2-0000 150 23
DCA015004 150 0.65 66 2-0000 150 52
DCA020002 200 0.21 50 2-0000 150 39
For additional information, visit http://www.mtecorp.com/dclink.html

454
Micro MAX™ AC Inverter Duty Motor
1000:1 Constant Torque (TENV) • 20:1 Constant Torque (TEFC)
Designed for direct replacement of PMDC or any other variable speed application where up to a 1000:1 constant torque speed range
is required. Typical uses include: machine tools, conveyors, packaging machines, batching machines and printing equipment.

• Replaces 90 and 180 volt PMDC motors when used with • Continuous duty at 40°C ambient
AC variable frequency drives • “Quick Connect” terminal board as noted
• Constant torque operation from 0 to base speed (TENV ratings) • Top mounted conduit box with pigtail leads
• Constant torque operation from 1/20 speed to base speed (TEFC and 1.5Hp TENV)
(TEFC ratings) • UL recognized and CSA certified
• Constant horsepower to twice base speed (RPM) • Three year warranty
• Class H insulation with CR200 magnetic wire

C-Face with Rigid Base


Hp RPM Volts Encl. Frame Catalog No. F.L.A. Weight Notes
1/8 1800 230 TENV 56C Y605 * 1.0 18 N, Q
1/4 1800 230 TENV 56C Y500 * 1.0 18 N, Q
1/3 1800 230 TENV 56C Y502 * 1.2 18 N, Q
1800 230 TENV 56C Y504 * 1.8 20 N, Q
1/2 1800 230/460 TENV 56C Y360 * 1.8/0.9 20 N
1800 575 TENV 56C Y361 * 0.7 20 N, Q
1800 230 TEFC 56C Y506 * 2.8 23 -
3/4 1800 230/460 TEFC 56C Y362 * 2.8/1.4 23 -
1800 575 TEFC 56C Y363 1.1 23 -
1800 230 TEFC 56C Y508 * 3.2 28 -
1 1800 230/460 TEFC 56C Y364 * 3.2/1.6 28 -
1800 575 TEFC 56C Y365 * 1.3 28 -
1800 230 TENV 145TC Y522 * 4.8 49 N, 6
1 1/2 1800 230/460 TENV 145TC Y366 * 4.8/2.4 49 N, 6
1800 575 TENV 145TC Y367 * 1.9 49 N, 6
1800 230 TEFC 145TC Y523 * 5.8 50 6
2 1800 230/460 TEFC 145TC Y368 * 5.8/2.9 50 6
1800 575 TEFC 145TC Y369 * 2.3 50 6
1800 230 TEFC 182TC Y998 8.4 70 -
3 1800 230/460 TEFC 182TC Y999 * 8.4/4.2 70 -
1800 575 TEFC 182TC Y270 3.5 70 -
1800 230/460 TEFC 184TC Y372 * 13.4/6.7 88 6
5
1800 575 TEFC 184TC Y373 5.4 88 6
1800 230/460 TEFC 213TC Y994 * 21.4/10.7 125 -
7 1/2
1800 575 TEFC 213TC Y995 8.5 125 -
1800 230/460 TEFC 215TC Y996 * 28.0/14.0 135 -
10
1800 575 TEFC 215TC Y997 11.2 135 -
General Notes:
* Marathon Motors stock item.
For additional information visit www.marathonelectric.com/motors/search.asp

C-Face Footless
Hp RPM Volts Encl. Frame Catalog No. F.L.A. Weight Notes
1/8 1800 230 TENV 56C Y606 * 1.0 17 N, Q
1/4 1800 230 TENV 56C Y501 * 1.0 17 N, Q
1/3 1800 230 TENV 56C Y503 * 1.2 17 N, Q
1800 230 TENV 56C Y505 * 1.8 19 N, Q
1/2 1800 230/460 TENV 56C Y374 * 1.8/0.9 19 N
1800 575 TENV 56C Y375 * 0.7 19 N, Q
1800 230 TEFC 56C Y507 * 2.8 23
3/4 1800 230/460 TEFC 56C Y376 * 2.8/1.4 23
1800 575 TEFC 56C Y377 1.1 23
1800 230 TEFC 56C Y521 * 3.2 27
1 1800 230/460 TEFC 56C Y378 * 3.2/1.6 27
1800 575 TEFC 56C Y379 * 1.3 27
General Notes:
* Marathon Motors stock item.
N: Totally Enclosed Non Ventilated; Q: “Quick Connect” terminal board; 6: Bolt-on, removable base for footless mounting option.
For additional information visit www.marathonelectric.com/motors/search.asp

Mitsubishi Electric Automation | Variable Frequency Drives 455


n VARIABLE FREQUENCY DRIVES
Black MAX™ Vector Duty
1000:1 Constant Torque
Designed for inverter or vector duty applications where up to a 1000:1 constant torque speed range is required. Typical uses include:
material handling, machine tools, conveyors, crane & hoist, metal processing and other industrial machinery installed in dusty or
dirty environments.

• Class F MAX GUARD insulation system • Ball bearing


• Constant torque operation from 0 to base speed • Removable Base on some models as noted
on vector drive • F1 standard, field reversible to F2 (except where noted)
• Constant horsepower to twice base speed (RPM) • Encoder and brake provisions included on opposite drive end
• Continuous duty at 40°C ambient (maximum 10 lb-ft brake)
• Optimized for operation with IGBT inverter (NEMA Design A) • UL recognized and CSA certified
• Class F N/C thermostats • Three year warranty

Totally Enclosed Non-Ventilated, C-Face with Rigid Base


Hp RPM Volts Frame Catalog No. F.L.A. Weight Notes
1/4 1800 230/460 56C Y592 * 1.2/0.6 19 N, S, 13
1800 230/460 56C Y534 * 1.6/0.8 28 N, S, 6, 13
1/2
1800 575 56C Y555 * 0.6 28 N, S, 6, 13
1800 230/460 56C Y535 * 3.0/1.5 39 N, S, 6, 13
1800 575 56C Y556 * 1.2 40 N, S, 6, 13
1
1800 230/460 143TC Y536 * 3.0/1.5 43 N, S, 6, 13
1200 230/460 145TC Y537 * 3.8/1.9 49 N, S, 6, 13
1 1/2 1800 230/460 145TC Y538 * 4.8/2.4 50 N, S, 6, 13
1800 230/460 145TC Y551 * 6.0/3.0 70 N
2 1800 575 145TC Y557 * 2.4 70 N
1200 230/460 184TC Y540 * 6.6/3.3 88 N, AL
1800 230/460 182TC Y541 * 8.4/4.2 93 N, AL
3 1800 575 182TC Y558 * 3.4 98 N, AL
1200 230/460 213TC Y542 * 9.4/4.7 118 N, AL
1800 230/460 184TC Y543 * 14.0/7.0 103 N, AL
5 1800 575 184TC Y559 * 5.4 103 N, AL
1200 230/460 215TC Y544 * 15.4/7.7 128 N, AL
1800 230/460 213TC Y545 * 21.0/10.5 146 N, AL
7 1/2 1800 575 213TC Y560 * 8.4 150 N, AL
1200 230/460 254TC Y546 * 22.0/11.0 209 N, AL
1800 230/460 215TC Y547 * 27.0/13.5 159 N, AL
10 1800 575 215TC Y561 * 10.8 159 N, AL
1200 230/460 256TC Y548 * 28.0/14.0 275 N, AL
1800 230/460 254TC Y549 * 40.0/20.0 250 N, AL, I
15
1800 575 254TC Y562 * 16.0 250 N, AL, I
1800 230/460 256TC Y552 * 50.0/25.0 320 N, I
20
1800 575 256TC Y563 * 20.0 320 N, I
1800 230/460 284TC Y553 * 62.0/31.0 525 N, I
25
1800 575 284TC Y567 * 24.8 525 N, I
30 1800 230/460 286TC Y393 * 80.0/40.0 575 N, I
General Notes:
* Marathon Motors stock item. Shaded areas are cast iron frames.
AL: Aluminum Frame Construction; N: Totally Enclosed Non-Ventilated; I: Intermittent duty from 90-120Hz operation; S: Steel Frame Construction; 6: Bolt-on, removable base for footless
mounting option; 13: F1 Mounting only, cannot modify to F2.
For additional information visit www.marathonelectric.com/motors/search.asp

Black MAX™ Vector Duty: Encoders through Mod Center


Brand Model PPR Catalog No. Notes
1024 A746*
HS25A Optical Hollow Shaft, MS connector
2048 A747*
1024 A736*
HS35A Optical Hollow Shaft, MS connector
2048 A739*
Avtron
1024 A742*
HS35M Magnetic Hollow Shaft, EPIC connector
2048 A744
M3 1024 A753* Optical Hollow Shaft, EPIC connector
M56 1024 A793* Magnetic Modular Style, EPIC connector
1024 A772*
Dynapar HS35 Shaft mount, 5-26VDC, with 10 pin connector
2048 A776*
1024 A779*
BEI HS35 Shaft mount, 5-26VDC, with 10 pin connector
2048 A780*
General Notes:
* Marathon Motors stock item.
For additional information visit www.marathonelectric.com/motors/search.asp

456
Blue MAX™ 2000 Vector Duty
2000:1 Constant Torque
Designed for inverter or vector duty applications where up to a 2000:1 constant torque speed range is required. Typical uses
include: material handling, machine tools, conveyors, crane & hoist, metal processing, test stands, pumps, compressors, textile
processing and other industrial machinery installed in dusty or dirty environments where cast iron construction is required.

• Class H MAX GUARD insulation system • Ball bearing (roller bearing available 360 frame and larger)
• Constant torque operation from 0 to base speed on vector • Cast iron frame and brackets
drive, including TEFC (on V/Hz drives, TEFC motors are • Patented “fracket” design (TEBC enclosure)
limited to 20:1 Constant Torque)
• “B” temperature rise on Blower-Cooled motors
• Constant horsepower to twice base speed (143-254 frame);
1.5 times base (all others) • F1 standard, field reversible to F2
• Continuous duty at 40°C ambient • Encoder and brake provisions included on opposite drive end
• Optimized for operation with IGBT inverter (NEMA Design A) • UL recognized and CSA certified
• C-Face foot mount through 100 Hp as noted • Three year warranty
• Class F N/C thermostats

Totally Enclosed Rigid Base, and C-Face with Rigid Base


Hp RPM Volts Encl. Frame Catalog No. F.L.A. Weight Notes
1 1800 230/460 TENV 143TC Y525 * 3.0/1.5 61 NEMA Design B
1 1/2 1800 230/460 TENV 145TC Y590 * 4.6/2.3 68
2 1800 230/460 TENV 145TC Y526 * 6.0/3.0 70
3 1800 230/460 TENV 182TC Y527 * 8.0/4.0 110
5 1800 230/460 TENV 184TC Y564 * 13.4/6.7 117 NEMA Design B
1800 230/460 TEFC 213TC Y595 * 19.4/9.7 191
7 1/2
1800 230/460 TENV 213TC Y565 * 21.0/10.5 180
1800 230/460 TEFC 215TC Y596 * 25.4/12.7 211
10
1800 230/460 TENV 215TC Y566 * 26.0/13.0 290
1800 230/460 TEFC 254TC Y597 * 37.0/18.5 339
15 1800 230/460 TENV 254TC Y509 * 40.4/20.2 350
1200 230/460 TEBC 284TC Y395 * 40.0/20.0 480
1800 230/460 TEFC 256TC Y598 * 52.0/26.0 375
20 1800 230/460 TENV 256TC Y510 * 50.0/25.0 380
1200 230/460 TEBC 286TC Y582 52.4/26.2 500 NEMA Design B
1800 230/460 TEFC 284T Y569 * 63.0/31.5 492
25 1800 230/460 TEBC 284TC Y511 * 63.0/31.5 500
1200 230/460 TEBC 324TC Y583 * 67.0/33.5 620 NEMA Design B
1800 230/460 TEFC 286T Y570 * 77.0/38.5 594
30 1800 230/460 TEBC 286TC Y512 * 74.0/37.0 520
1200 230/460 TEBC 326TC Y584 * 82.0/41.0 686 NEMA Design B
1800 230/460 TEFC 324T Y571 * 100/50.0 540
40 1800 230/460 TEBC 324TC Y513 * 100/50.0 620
1200 230/460 TEBC 364TC Y585 * 104/52.0 1050
1800 230/460 TEFC 326T Y572 * 121/60.5 540
50 1800 230/460 TEBC 326TC Y514 * 120/60.0 640
1200 230/460 TEBC 365TC Y586 130/65.0 1100
General Notes:
* Marathon Motors stock item.
1. B: NEMA Design B.
2. For additional information visit www.marathonelectric.com/motors/search.asp

Mitsubishi Electric Automation | Variable Frequency Drives 457


n VARIABLE FREQUENCY DRIVES
Totally Enclosed Rigid Base, and C-Face with Rigid Base (continued)
Hp RPM Volts Encl. Frame Catalog No. F.L.A. Weight Notes
1800 230/460 TEFC 364T Y573 * 147/73.5 965
60 1800 230/460 TEBC 364TC Y515 * 147/73.5 1062
1200 230/460 TEBC 404TC Y587 * 142/71.0 1380
1800 230/460 TEFC 365T Y574 * 184/92.0 1006
75 1800 230/460 TEBC 365TC Y516 * 180/90.0 1106
1200 230/460 TEBC 405TC Y588 * 180/90.0 1450 NEMA Design B
1800 230/460 TEFC 405T Y575 * 230/115 1308
100 1800 230/460 TEBV 405TC Y517 * 230/115 1429
1200 230/460 TEBC 444TC Y589 * 250/125 2150
1800 460 TEFC 444T Y576 * 143 2062
125
1800 460 TEBC 444T Y518 * 138 2110 NEMA Design B
1800 460 TEFC 445T Y577 * 170 2246
150
1800 460 TEBC 445T Y519 * 170 2321
1800 460 TEFC 445T Y578 * 230 2404
200
1800 460 TEBC 445T Y520 * 230 2457
1800 460 TEFC 449T Y579 295 2800
250
1800 460 TEBC 449T Y531 * 295 2880
1800 460 TEFC 449T Y580 330 2890 20:1
300
1800 460 TEBC 449T Y532 * 327 2950
350 1800 460 TEBC 449T Y533 * 385 3075
General Notes:
* Marathon Motors stock item.
B: NEMA Design B.
For additional information visit www.marathonelectric.com/motors/search.asp

Blue MAX™ 2000 Vector Duty / Encoders Through Mod Center


Encl. Brand Model PPR Catalog No. Notes
1024 A746*
HS25A Optical Hollow Shaft, MS connector
2048 A747*
1024 A736*
HS35A Optical Hollow Shaft, MS connector
2048 A739*
Avtron
1024 A742*
HS35M Magnetic Hollow Shaft, EPIC connector
2048 A744
TENV
M3 1024 A753* Optical Hollow Shaft, EPIC connector
M56 1024 A793* Magnetic Modular Style, EPIC connector
1024 A772*
Dynapar HS35 Shaft mount, 5-26VDC, with 10 pin connector
2048 A776*
1024 A779*
BEI HS35 Shaft mount, 5-26VDC, with 10 pin connector
2048 A780*
1024 A737*
HS35A Optical Hollow Shaft, MS connector
2048 A740
Avtron 1024 A742*
HS35M Magnetic Hollow Shaft, EPIC connector
2048 A744
TEFC M3 1024 A754* Optical Hollow Shaft, EPIC connector
1024 A774*
Dynapar HS35 Shaft mount, 5-26VDC, with 10 pin connector
2048 A777*
1024 A783*
BEI HS35 Shaft mount, 5-26VDC, with 10 pin connector
2048 A784*
1024 A738*
HS35A Optical Hollow Shaft, MS connector
2048 A741*
Avtron 1024 A743*
HS35M Magnetic Hollow Shaft, EPIC connector
2048 A745
M56 1024 A794* Magnetic Modular Style, EPIC connector
TEBC
1024 A775*
Dynapar HS35 Shaft mount, 5-26VDC, with 10 pin connector
2048 A778*
1024 A781*
BEI HS35 Shaft mount, 5-26VDC, with 10 pin connector
2048 A782*
- - - A801* Encoder Conduit box
General Notes:
* Marathon Motors stock item.
For additional information visit www.marathonelectric.com/motors/search.asp

458

You might also like