Variable Frequency Drives A700
Variable Frequency Drives A700
Variable Frequency Drives A700
A700
F700
F700 1 - 1000 Hp
E700 1/8 - 20 Hp
E E
E500
E560 1 - 10 Hp
D700 1/8 - 10 Hp
CAPACITY
Stock Product: Stock product is product MEAU makes every effort to have on hand for immediate shipment. There may be instances
when we are out of stock due to unexpected large requirements. All stock product will be indicated in this book by an “S” in the
Stocked Item columns/rows.
Non-Stock Product: Non-stock product is product supplied on an “as-needed” basis. Standard lead times of 12 - 16 weeks apply,
product is non-returnable and non-cancelable. Product listed as non-stock may change to stock product subject to increases in sales
and usage. All non-stock product will be indicated in this book by a dash “-” in the Stocked Item columns/rows.
1/8~1 1/8~3 1/8~10 1/2~10 1~10 1/8~1 1/8~3 1/8~20 1/2~20 1~200 1~1000
HP
4~20mA No Yes No No No
4~20mA or 0~5/10VDC Yes No Yes Yes (2 ports) Yes (2 ports)
Pulse (Speed) No No No No Yes
Digital Outputs 1 2 2 (expandable) 5 (expandable) 5 (expandable)
Relay Outputs 1 1 1 (expandable) 2 (expandable) 2 (expandable)
Outputs
SSCNETIII No No No No Option
ControlNET No No No No Option
Metasys N2 Option Option Option Option Option
Siemens FLN Option Option Option Option Option
BACnet/MS/TP Standard Option Option Option Option
EtherNet/IP Option Option Option Option Option (2 types)
Modbus TCP/IP Option Option Option Option Option
BACnet/IP No No Option Option Option
Brake Transistor Yes (1/2HP and above) Yes Yes (1/2HP and above) No Up to 30HP
Up to
Brake Resistor Option Option Option No Up to 10HP
5HP
EMC Filter Option No Option Standard Standard No
DC Reactor Option No Option Option (standard 100HP and above)
Safety Stop Function Standard No Option No No
1
Communications Ports 1 (RS-485) 2 (RS-485 & USB) 2 (RS-485) 3 (2x RS-485 & USB)
(RS485)
Plug-in Option Ports 0 1 1 1 3
Operator Interface Standard Option Standard Standard Standard
FR-PU07
Alpha/Numeric Keypad Option FR-PU07 FR-PU04 FR-PU07 FR-PU07
FR-PU07-01
Alarm History Last 8 Last 8 Last 8 Last 8 Last 8
398
D700 Series
Low cost micro VFD with Mitsubishi Electric quality.
• Simple to use: The D700 is perfect for a wide range • 150% torque at 1Hz and 200% torque at 3Hz using
of applications General-purpose Magnetic Flux Vector Control
• Simple to set up: The integrated digital setting dial • Optimum Excitation Control for increased energy
with display makes configuration fast and easy savings when motor is not loaded
• Simple operation: Control remotely or with the • Frequency search function for catching a
built-in digital control spinning load
• Simple to choose: Low cost and with Mitsubishi • Dancer control allows position signal to control
Electric quality ensuring long operation life roll tension
• Capacity from 1/8 to 10 HP • Password function for parameter setting protection
• Safety stop function meets EN954-1 Category 3 and • Internal diagnostics function for monitoring status
IEC60204-1 Stop Category 0 of critical components
• Integrated brake chopper circuit • RoHS compliant
• Modbus RTU included as standard via the RJ45 port • 10 year maintenance free design
Voltage
115
1 Phase 1/8 – 1 Hp
FR-D720 – 008 – NA
240
1 Phase 1/8 – 3 Hp
240
1/8 – 10 Hp
Symbol Voltage Class 3 Phase
Inverter capacity
D710W 1-phase 115V class 480
amperage / 10 1/2 – 10 Hp
D720S 1-phase 240V class 3 Phase
(008 = 0.8A
D720 3-phase 240V class
output)
D740 3-phase 480V class Horsepower
D700 Series
Rating (CT & VT) IP20 Open Chassis Dimensions in inches (mm)
Weight Lbs (kg) Stocked Item
HP Rated Amps Model Number Height Width Depth
1-Phase 100~120VAC Input / 3-Phase 200~240VAC Output
1/8 0.8 FR-D710W-008-NA 5.0 (128) 2.7 (68) 3.2 (80.5) 1.1 (0.5) S
1/4 1.4 FR-D710W-014-NA 5.0 (128) 2.7 (68) 4.4 (110.5) 1.3 (0.6) S
1/2 2.5 FR-D710W-025-NA 5.0 (128) 2.7 (68) 5.6 (142.5) 2.0 (0.9) S
1 4.2 FR-D710W-042-NA 5.0 (128) 4.3 (108) 5.9 (149.5) 3.1 (1.4) S
1-Phase 200~240VAC Input / 3-Phase 200~240VAC Output
1/8 0.8 FR-D720S-008-NA 5.0 (128) 2.7 (68) 3.2 (80.5) 1.1 (0.5) S
1/4 1.4 FR-D720S-014-NA 5.0 (128) 2.7 (68) 3.2 (80.5) 1.3 (0.6) S
1/2 2.5 FR-D720S-025-NA 5.0 (128) 2.7 (68) 5.6 (142.5) 2.0 (0.9) S
1 4.2 FR-D720S-042-NA 5.0 (128) 2.7 (68) 6.5 (162.5) 2.5 (1.1) S
2 7 FR-D720S-070-NA 5.0 (128) 4.3 (108) 6.2 (155.5) 3.3 (1.5) S
3 10 FR-D720S-100-NA 5.9 (150) 5.5 (140) 5.7 (145) 4.4 (2.0) S
3-Phase 200~240VAC Input & Output
1/8 0.8 FR-D720-008-NA 5.0 (128) 2.7 (68) 3.2 (80.5) 1.1 (0.5) S
1/4 1.4 FR-D720-014-NA 5.0 (128) 2.7 (68) 3.2 (80.5) 1.1 (0.5) S
1/2 2.5 FR-D720-025-NA 5.0 (128) 2.7 (68) 4.5 (112.5) 1.8 (0.8) S
1 4.2 FR-D720-042-NA 5.0 (128) 2.7 (68) 5.3 (132.5) 2.2 (1.0) S
2 7 FR-D720-070-NA 5.0 (128) 4.3 (108) 5.4 (135.5) 3.1 (1.4) S
3 10 FR-D720-100-NA 5.0 (128) 4.3 (108) 5.4 (135.5) 3.1 (1.4) S
5 16.5 FR-D720-165-NA 5.0 (128) 6.7 (170) 5.6 (142.5) 4.0 (1.8) S
7 1/2 23.8 FR-D720-238-NA 5.9 (150) 8.7 (220) 6.1 (155) 8.0 (3.6) S
10 31.8 FR-D720-318-NA 5.9 (150) 8.7 (220) 6.1 (155) 8.0 (3.6) S
3-Phase 380~480VAC Input & Output
1/2 1.2 FR-D740-012-NA 5.0 (128) 4.3 (108) 5.1 (129.5) 2.9 (1.3) S
1 2.2 FR-D740-022-NA 5.0 (128) 4.3 (108) 5.1 (129.5) 2.9 (1.3) S
2 3.6 FR-D740-036-NA 5.0 (128) 4.3 (108) 5.4 (135.5) 3.1 (1.4) S
3 5 FR-D740-050-NA 5.0 (128) 4.3 (108) 6.2 (155.5) 3.3 (1.5) S
5 8 FR-D740-080-NA 5.0 (128) 4.3 (108) 6.6 (165.5) 3.3 (1.5) S
7 1/2 12 FR-D740-120-NA 5.9 (150) 8.7 (220) 6.1 (155) 7.3 (3.3) S
10 16 FR-D740-160-NA 5.9 (150) 8.7 (220) 6.1 (155) 7.3 (3.3) S
Frequency
Accuracy Digital Input Within 0.01% of the set output frequency
Voltage/Frequency Characteristics Base frequency can be set from 0 to 400Hz. Constant torque/variable torque pattern can be selected
Starting Torque 150% or more (at 1Hz) when General-purpose magnetic flux vector control and slip compensation is set
Torque Boost Manual torque boost
Accel. /Decel. Time Setting 0.01 to 3600s (acceleration and deceleration can be set individually), linear or S-pattern acceleration/deceleration mode can be selected.
FR-D720-008 and 014, FR-D720S-008 and 014, FR-D710W-008 and 014 ... 150%, FR-D720-025 and 042, FR-D740-012 and 022,
Regeneration
FR-D720S-025 and 042, FR-D710W-025 and 042 ... 100%, FR-D720-070, FR-D740-036, FR-D720S-070 ... 50%, FR-D720-100 or
(*1)
Braking Torque more, FR-D740-050 or more, FR-D720S-100 ... 20%
DC Injection
Operation frequency (0 to 120Hz), operation time (0 to 10s), operation voltage (0 to 30%) variable
Brake
Stall Prevention Operation Level Operation current level can be set (0 to 200% adjustable), whether to use the function or not can be selected
Two points
Frequency Setting Analog Input Terminal 2: 0 to 10V, 0 to 5V can be selected
Signal Terminal 4: 0 to 10V, 0 to 5V, 4 to 20mA can be selected
Digital Input Entered from operation panel and parameter unit. Frequency setting increments is selectable.
Start Signal Forward and reverse rotation or start signal automatic self-holding input (3-wire input) can be selected.
Five points. You can select from among multi-speed selection, remote setting, second function selection, terminal 4 input selection,
JOG operation selection, PID control valid terminal, external thermal input, PU-external operation switchover, V/F switchover, output
Input Signal
stop, start self-holding selection, forward rotation, reverse rotation command, inverter reset, PU-NET operation switchover, external-
NET operation switchover, command source switchover, inverter operation enable signal, and PU operation external interlock
Maximum/minimum frequency setting, frequency jump operation, external thermal relay input selection, automatic restart after
Operation Specifications
instantaneous power failure operation, forward/reverse rotation prevention, remote setting, second function, multi-speed operation,
Operational Functions
regeneration avoidance, slip compensation, operation mode selection, offline auto tuning function, PID control, computer link
operation (RS-485), Optimum excitation control, power failure stop, speed smoothing control, Modbus-RTU
Open Collector
Output Signal One point
Output
Points
Relay Output One point
You can select from among inverter operation, up-to-frequency, overload alarm, output frequency detection, regenerative brake
prealarm, electronic thermal relay function prealarm, inverter operation ready, output current detection, zero current detection, PID
Output Signal
Operating Status lower limit, PID upper limit, PID forward/reverse rotation output, fan alarm (*3), heatsink overheat pre-alarm, deceleration at an
instantaneous power failure, PID control activated, PID output interruption, during retry, life alarm, current average value monitor,
remote output, alarm output, fault output, fault output 3, and maintenance timer alarm
For Meter
Analog Output 0 to 10VDC: one point
Output Points
You can select from among output frequency, output current (steady), output voltage, frequency setting, converter output voltage,
regenerative brake duty, electronic thermal relay function load factor, output current peak value, converter output voltage peak value,
For Meter
reference voltage output, motor load factor, PID set point, PID measured value, output power, PID deviation, motor thermal load
factor, inverter thermal load factor 0 to 10VDC
You can select from among output frequency, output current (steady), output voltage, frequency setting, cumulative energization time,
actual operation time, converter output voltage, regenerative brake duty, electronic thermal relay function load factor, output current
Operation Panel Operating Status
peak value, converter output voltage peak value, motor load factor, PID set point, PID measured value, PID deviation, inverter I/O
Parameter Unit terminal monitor, output power, cumulative power, motor thermal load factor, inverter thermal load factor, PTC thermistor resistance.
(FR-PU07)
Indication
Fault definition is displayed when the fault occurs and the past 8 fault definitions (output voltage/current/frequency/cumulative
Fault Definition
energization time right before the fault occurs) are stored
Additional Display Operating Status Not used
By The Parameter Fault Definition Output voltage/current/frequency/cumulative energization time immediately before the fault occurs
Unit (FR-PU04/ Interactive
FR-PU07) Only Function (help) for operation guide
Guidance
Overcurrent during acceleration, overcurrent during constant speed, overcurrent during deceleration, overvoltage during acceleration,
overvoltage during constant speed, overvoltage during deceleration, inverter protection thermal operation, motor protection thermal
operation, heatsink overheat, input phase loss (*5, *6), output side earth (ground) fault overcurrent at start (*5), output phase loss,
Protective Functions
external thermal relay operation (*5), PTC thermistor operation (*5), parameter error, PU disconnection, retry count excess (*5), CPU
fault, brake transistor alarm, inrush resistance overheat, analog input error, stall prevention operation, output current detection value
exceeded (*5), safety circuit fault
Fan alarm (*3), overcurrent stall prevention, overvoltage stall prevention, PU stop, parameter write error, regenerative brake prealarm
Warning Functions (*5), electronic thermal relay function prealarm, maintenance output (*5), undervoltage, operation panel lock, password locked,
inverter reset, safety stop
Surrounding Air Temperature -10°C to +50°C (14°F to 122°F) (non-freezing) (*4)
Environment
400
D700 Series Terminal Connection Diagram
Control circuit
Control input signals (No voltage input allowed) C Relay output
Forward STF
Terminal functions vary rotation start Terminal functions vary
B by Pr. 192 A,B,C terminal
with the input terminal Reverse STR Relay output
assignment (Pr. 178 to rotation start (Fault output) function selection
A
Pr. 182) RH
High
speed
RM Open collector output
Multi-speed selection Middle
speed
SOURCE
B1
Drive Kit Model Dimensions mm (in)
φd1
Current Stocked Item
Voltage Number L W D A1
(mA) A2
5.3
208 - 230 FR-BIF 4 58 (2.3) 44 (1.8) 42 (1.7) S Glass-braided cable
B2
2.0mm2 white
460 FR-BIF-H 4 58 (2.3) 44 (1.8) 42 (1.7) - φd2
D
A2
H
Line Noise Filter
2.5
Provides a toroid for line noise reduction. Brake Resistor Model Dimensions (mm)
Kit Model Dimensions mm (in) W W1 W2 D H
Drive Hp Stocked Item
Number L W D 200V Class
FR-ABR-0.4K 140 125 100 40 21
0.5 - 5 FR-BSF01 110 (4.33) 22.5 (0.89) 65 (2.56) S
FR-ABR-0.75K 215 200 175 40 21
0.5 - 75 FR-BLF 180 (7.07) 31.5 (1.24) 83 (3.27) S FR-ABR-2.2K 240 225 200 50 26
FR-ABR-3.7K 215 200 175 61 33
FR-ABR-5.5K 335 320 295 61 33
D700 EMC Filters FR-ABR-7.5K 400 385 360 80 40
FR-ABR-11K 400 385 360 100 50
This attachment allows the VFD to be mounted onto the filter.
FR-ABR-15K (*1) 300 285 260 100 50
Model Number Drive Model Stocked Item 400V Class
FFR-CS-050-14A-RF1 D720S-008 to 042 - FR-ABR-H0.4K 115 100 75 40 21
FFR-CS-080-20A-RF1 D720S-070 - FR-ABR-H0.75K 140 125 100 40 21
FR-ABR-H1.5K 215 200 175 40 21
FFR-CS-110-26A-RF1 D720S-100 -
FR-ABR-H2.2K 240 225 200 50 26
FFR-CSH-036-8A-RF1 D740-012 to 036 - FR-ABR-H3.7K 215 200 175 61 33
FFRCSH-080-16A-RF1 D740-050 to 080 - FR-ABR-H5.5K 335 320 295 61 33
FFRMSH-170-30A-RF1 D740-120 to 160 - FR-ABR-H7.5K 400 385 360 80 40
FR-ABR-H11K 400 385 360 100 50
FR-ABR-H15K (*2) 300 285 260 100 50
Notes:
DIN Rail Mounting Attachment 1. For the 15K, connect the two supplied resistors (18 ohms) in parallel
This attachment allows the D700 Series inverter to mount on a 35mm DIN rail. 2. For the H15K, connect the two supplied resistors (18 ohms) in series.
Drive Model
Model Number Stocked Item
D710W D720S D720 D740 D700 Conduit Kits
FR-UDA01 008-025 008-042 008-042 - S
Kit Model Part Number Stocked
FR-UDA02 042 070 070-100 012-080 S
Number FR-D710W- FR-D720S- FR-D720- FR-D740- Item
FR-UDA03 - - 165 - -
FR-E7FN-01 008/014 008/014 008/014 - S
FR-E7FN-02 - - 025 - S
D700 Demonstration Unit FR-E7FN-03 - - 042 - S
FR-E7FN-04 - - 070/100 036 S
Model Number Description Stocked Item
FR-E7FN-06 - - - - S
Includes E720 and D720 1HP, pre-wired digital input FR-E7FN-07 - - 165 - S
VFD-MICRO-DEMO S
switches, led outputs and speed potentiometer
FR-E7FN-08 - - 238/318 120/160 S
Includes 1/2HP motor with quick connection to
VFD-MOTOR-DEMO S FR-E7FN-11 - - - 012/022 -
VFD-MICRO-DEMO
FR-E7FN-12 - - - 050/080 -
402
D700 Heatsink Extension Kits D700 Building Management Options
Kit Model Part Number ETH-1000 XLTR-1000
Stocked Item Network Type / Model
Number (*2, *3) (*2, *3)
FR-D710W- FR-D720S- FR-D720- FR-D740-
BACnet/IP X -
FR-E7CN-02 025 025 025 - S
EtherNet/IP X -
FR-E7CN-03 - 042 042 - S Gateway Modbus/TCP X -
FR-E7CN-04 - 070 070/100 036 to 080 S Communication Profinet IO X -
FR-E7CN-06 - 100 - - S BACnet MS/TP X X
Metasys N2 X X
FR-E7CN-07 - - 165 - S
Stocked Item - -
FR-E7CN-08 042 - 238/318 120/160 S
Notes:
FR-E7CN-11 - - - 012/022 - 1. For additional information, visit www.iccdesigns.com
2. Communication to multiple VFD’s is possible
3. Mounted and powered external to VFD
All Mitsubishi Electric VFDs have some inherent braking capability. During controlled deceleration, motor regenerative losses are
dissipated in the motor, wire, and VFD circuitry. The built-in DC injection braking allows for low speed braking and stopping.
When the above capabilities are inadequate for an application, it is necessary to add a power transistor brake unit and resistor unit in
series across the DC bus. Motor regeneration causes the DC bus voltage to increase, and when the voltage exceeds a specified threshold,
the transistor turns on to pass current through the resistor. Motor kinetic energy is converted to heat energy. VFD overcurrent and
overvoltage protective circuits are active at all times, and will fault-trip the VFD if the brake size is inadequate.
Two main factors must be considered when sizing the brake, the effective duty cycle (%ED) and the short time duty rating. The
effective duty cycle is increased when an external resistor is added. It is preferable to profile the effective duty cycle of the units of time.
With this information, the short time duty is known and the %ED can be calculated, as shown in the below example.
%ED = Braking time / total time for complete operating cycle *100
404
E700 Series
The cost-effective variable speed control solution for general purpose applications.
115
1 Phase 1/8 – 1 Hp
E700 Series
Dimensions in inches (mm)
HP Output Amps Model Number Weight Lbs (kg) Stocked Item
Height Width Depth
1-Phase 100~120VAC Input / 3-Phase 200~240VAC Output
1/8 0.8 FR-E710W-008-NA 5.0 (128) 2.7 (68) 3.2 (80.5) 1.1 (0.5) S
1/4 1.5 FR-E710W-015-NA 5.0 (128) 2.7 (68) 4.4 (110.5) 1.3 (0.6) S
1/2 3 FR-E710W-030-NA 5.0 (128) 2.7 (68) 4.5 (112.5) 2.0 (0.9) S
1 5 FR-E710W-050-NA 5.0 (128) 6.7 (170) 6.1 (155) 7.5 (3.4) S
1-Phase 200~240VAC Input / 3-Phase 200~240VAC Output
1/8 0.8 FR-E720S-008-NA 5.0 (128) 2.7 (68) 3.2 (80.5) 1.1 (0.5) S
1/4 1.5 FR-E720S-015-NA 5.0 (128) 2.7 (68) 3.2 (80.5) 1.1 (0.5) S
1/2 3 FR-E720S-030-NA 5.0 (128) 2.7 (68) 6.2 (157.6) 1.3 (0.6) S
1 5 FR-E720S-050-NA 5.0 (128) 4.3 (108) 5.4 (135.5) 3.1 (1.4) S
2 8 FR-E720S-080-NA 5.0 (128) 4.3 (108) 6.4 (161) 3.1 (1.4) S
3 11 FR-E720S-110-NA 5.9 (150) 5.5 (140) 6.2 (155.5) 4.2 (1.9) S
3-Phase 200~240VAC Input & Output
1/8 0.8 FR-E720-008SC-NA S
5.0 (128) 2.7 (68) 3.4 (87) 1.1 (0.5)
1/4 1.5 FR-E720-015SC-NA S
1/2 3 FR-E720-030SC-NA 5.0 (128) 2.7 (68) 4.7 (120) 1.6 (0.7) S
1 5 FR-E720-050SC-NA 5.0 (128) 2.7 (68) 5.5 (139) 2.2 (1.0) S
2 8 FR-E720-080SC-NA S
5.0 (128) 4.3 (108) 5.6 (142) 3.1 (1.4)
3 11 FR-E720-110SC-NA S
5 17.5 FR-E720-175SC-NA 5.0 (128) 6.7 (170) 5.9 (149) 3.8 (1.7) S
7 1/2 24 FR-E720-240SC-NA S
10.3 (260) 7.1 (180) 6.9 (171) 9.5 (4.3)
10 33 FR-E720-330SC-NA S
15 47 FR-E720-470SC-NA S
10.3 (260) 8.7 (220) 7.7 (196) 19.9 (9)
20 60 FR-E720-600SC-NA S
3-Phase 380~480VAC Input & Output
1/2 1.6 FR-E740-016SC-NA S
5.9 (150) 5.5 (140) 4.7 (120) 3.1 (1.4)
1 2.6 FR-E740-026SC-NA S
2 4 FR-E740-040SC-NA S
3 6 FR-E740-060SC-NA 5.9 (150) 5.5 (140) 5.6 (142) 4.2 (1.9) S
5 9.5 FR-E740-095SC-NA S
7 1/2 12 FR-E740-120SC-NA S
5.9 (150) 8.7 (220) 6.0 (153) 7.1 (3.2)
10 17 FR-E740-170SC-NA S
15 23 FR-E740-230SC-NA S
10.3 (260) 8.7 (220) 7.7 (196) 19.9 (9)
20 30 FR-E740-300SC-NA S
Maximum/minimum frequency setting, frequency jump operation, external thermal relay input selection, automatic restart after
instantaneous power failure operation, forward/reverse rotation prevention, remote setting, brake sequence, second function, multi-
Operational Functions
speed operation, stop-on contact control, droop control, regeneration avoidance, slip compensation, operation mode selection, offline
auto tuning function, PID control, computer link operation (RS-485)
Safety stop function (*1) Safety shutoff signal can be input from terminals S1 and S2. (compliant with EN954-1 Cat.3)
Open Collector
Output Signal Two terminals
Output
Points
Relay Output One terminal
The following signals can be assigned to Pr.190 to Pr.192 (output terminal function selection): inverter operation, upto-frequency,
overload alarm, output frequency detection, regenerative brake prealarm, electronic thermal relay function prealarm, inverter operation
ready, output current detection, zero current detection, PID lower limit, PID upper limit, PID forward/reverse rotation output, brake
Output Signal
Operating Status
opening request, fan alarm, heatsink overheat prealarm, deceleration at an instantaneous power failure, PID control activated, safety
monitor output (*1), safety monitor output2 (*1), during retry, life alarm, current average value monitor, remote output, alarm output,
fault output, fault output 3, and maintenance timer alarm
For Meter
Analog Output 0 to 10VDC: one terminal
Output Points
The following signals can be assigned to Pr.158 AM terminal function selection: output frequency, motor current (steady), output
voltage, frequency setting, motor torque, converter output voltage, regenerative brake duty, electronic thermal relay function load
For Meter
factor, output current peak value, converter output voltage peak value, reference voltage output, motor load factor, PID set point, PID
measured value, output power 0 to 10VDC
The following operating status can be displayed: output frequency, motor current (steady), output voltage, frequency setting,
cumulative energization time, actual operation time, motor torque, converter output voltage, regenerative brake duty, electronic
Operating
thermal relay function load factor, output current peak value, converter output voltage peak value, motor load factor, PID set point,
Status
PID measured value, PID deviation, inverter I/O terminal monitor, I/O terminal option monitor, output power, cumulative power, motor
Indication
Operation Panel
Parameter Unit thermal load factor, and inverter thermal load factor.
(FR-PU07) Fault definition is displayed when the fault occurs and the past 8 fault definitions (output voltage/current/frequency/cumulative
Fault Definition
energization time right before the fault occurs) are stored
Interactive
Function (help) for operation guide (*2)
Guidance
Overcurrent during acceleration, overcurrent during constant speed, overcurrent during deceleration, overvoltage during acceleration,
overvoltage during constant speed, overvoltage during deceleration, inverter protection thermal operation, motor protection thermal
operation, heatsink overheat, input phase failure (*4), output side earth (ground) fault overcurrent at start (*4), output phase failure,
Protective Function
external thermal relay operation (*3), option fault (*3), parameter error, internal board fault, PU disconnection, retry count excess (*4),
CPU fault, brake transistor alarm, inrush resistance overheat, communication error, analog input error, USB communication error,
brake sequence error 4 to 7 (*3), safety circuit fault (*1)
Fan alarm, overcurrent stall prevention, overvoltage stall prevention, PU stop, parameter write error,
Warning Function regenerative brake prealarm (*3), electronic thermal relay function prealarm, maintenance output (*3), undervoltage,
operation panel lock, password locked, inverter reset, safety stop (*1)
Ambient Temperature -10°C to +50°C (14°F to 122°F) (non-freezing) (*5)
Environment
406
E700 Series Terminal Connection Diagram
One-phase 100V power input
Three-phase 200V power input
Three-phase 400V power input
Sink logic
Main circuit terminal *1. DC reactor (FR-HEL)
Control circuit terminal When connecting a DC reactor, remove the *6 A brake transistor is not built-in to the
jumper across P1-P/+ FR-E720-008SC and 015SC, FR-E720S-
Single-phase power input 008SC and 015SC.
Brake unit
MCCB MC (Option)
*7 Brake resistor (FR-ABR, MRS, MYS type)
*1 Install a thermal relay to prevent an
Single-phase R/L1 R
AC power Earth overheat and burnout of the brake resistor.
S/L2 (Ground) *7
supply (The brake resistor can not be connected
Jumper PR N/- to the FR-E720-008SC and 015SC, FR-
E720S-008SC and 015SC.)
MCCB MC P1 P/+ *6
Motor
Three-phase R/L1 U
Inrush current
AC power S/L2 V
limit circuit IM
supply T/L3 W
Earth
(Ground)
Main circuit Earth (Ground)
Control circuit
Safety stop function model
Control input signals (No voltage input allowed)
Forward STF C Relay output
Terminal functions vary rotation start Terminal functions vary
with the input terminal Reverse STR B
Relay output by Pr. 192 A,B,C terminal
assignment (Pr. 178 to rotation start function selection
Pr. 184) RH (Fault output)
High A
speed
Multi-speed selection RM
Middle
speed Open collector output
*2 When using terminals PC-SD Low RL
RUN Terminal functions vary with
as a 24VDC power supply, speed the output terminal assignment
SOURCE
Connector for
plug-in option connection Option connector
FR-A7AR E KIT SC Additional Relay Output S FR-RJ45-HUB4 Serial Network Hub - 2 Stations -
Multidrop for Serial FR-RJ45-HUB10 Serial Network Hub - 8 Stations -
FR-E7TR S
Communication
FR-RJ45-TR Terminating Resistor For FR-RJ45-HUB -
Note: FR-E7TR ia not compatible with safety version of E700.
Note: _ _ represents drive kW rating
408
Brake Resistors
Dimensions (mm) W 500 +200
Brake Resistor Model
W W1 W2 D H W1 ±1
200V Class W2 A1
B1
FR-ABR-0.4K 140 125 100 40 21 φd1
FR-ABR-0.75K 215 200 175 40 21 A2 A1
5.3
FR-ABR-2.2K 240 225 200 50 26
FR-ABR-3.7K 215 200 175 61 33 Glass-braided cable
B2
FR-ABR-5.5K 335 320 295 61 33 2.0mm2 white
φd2
FR-ABR-7.5K 400 385 360 80 40 D
A2
FR-ABR-11K 400 385 360 100 50
H
FR-ABR-15K (*1) 300 285 260 100 50
400V Class
2.5
FR-ABR-H0.4K 115 100 75 40 21
FR-ABR-H0.75K 140 125 100 40 21
FR-ABR-H1.5K 215 200 175 40 21
FR-ABR-H2.2K 240 225 200 50 26
FR-ABR-H3.7K 215 200 175 61 33
FR-ABR-H5.5K 335 320 295 61 33
FR-ABR-H7.5K 400 385 360 80 40
FR-ABR-H11K 400 385 360 100 50
FR-ABR-H15K (*2) 300 285 260 100 50
Notes:
1. For the 15K, connect the two supplied resistors (18 ohms) in parallel.
2. For the H15K, connect the two supplied resistors (18 ohms) in series.
PROFINET IO X - X - X -
This attachment allows the E700 Series inverter to mount on a 35mm BACnet MS/TP - X - X X X
DIN rail. Metasys N2 - X - X X X
Drive Model Siemens FLN - X - X - -
Model Number Stocked Item Stocked Item S S S S - -
E720 (*1)
Notes:
FR-UDA01 008-050 S For additional information, visit www.iccdesigns.com
1. Cable E700-NET-CBL required accessory
FR-UDA02 080-110 S 2. Deeper cover required A7A-EKITCVR-SCSP
3. Deeper cover A7A-EKITCVR-SC required accessory
FR-UDA03 175 - 4. Communication to multiple VFDs is possible
5. Mounted and powered external to VFD
Notes:
1. Not available for 400V models.
410
E560 Series
The cost-effective variable speed control solution for general purpose applications.
FR-E560 – 3.7 K – NA
Voltage
Symbol Voltage Class Inverter
capacity
E560 Three-phase 600V class “kW” 600 1 – 10 Hp
Horsepower
E560 Series
Rating (CT & VT) IP20 Open Chassis Dimensions
Output Current Stocked Item
Hp Model Number H x W x D mm (in) Weight kg (lbs)
Amps
3-Phase 575 - 600VAC Input / Output
1 1.7 FR-E560-0.75K-NA 150 x 140 x 136 (5.9 x 5.5 x 5.4) 1.8 (4.0) S
2 2.7 FR-E560-1.5K-NA 150 x 140 x 136 (5.9 x 5.5 x 5.4) 2.0 (4.7) S
3 4.0 FR-E560-2.2K-NA 150 x 140 x 136 (5.9 x 5.5 x 5.4) 2.0 (4.7) S
5 6.1 FR-E560-3.7K-NA 150 x 220 x 148 (5.9 x 8.7 x 5.8) 3.8 (8.4) S
7.5 9.0 FR-E560-5.5K-NA 150 x 220 x 148 (5.9 x 8.7 x 5.8) 3.8 (8.4) S
10 12 FR-E560-7.5K-NA 150 x 220 x 148 (5.9 x 8.7 x 5.8) 3.8 (8.4) S
Voltage / Frequency Characteristics Base frequency set as required between 0 and 400Hz. Constant torque or variable torque pattern can be selected
150% or more (at 1Hz), 200% or more (at 3Hz) when general-purpose magnetic flux vector control or slip
Starting Torque
compensation is selected
Torque Boost Manual torque boost, 0 to 30% may be set
0.01, 0.1 to 3600 sec. (accel. and decel. can be set individually), linear or S-pattern accel./decel. mode can be
Acceleration / Deceleration Time Setting
selected
0.1K, 0.2K...150% or more, 0.4K, 0.75K... 00% or more, 1.5K...50% or more, 2.2K, 3.7K, 5.5K, 7.5K ... 20% or
Regenerative
Braking Torque more (*1)
DC Dynamic Brake Operation frequency (0 to 120Hz), operation time (0 to 10 s), operation voltage (0 to 30%) variable
Stall Prevention Operation Level Operation current level can be set (0 to 200% variable), presence or absence can be selected
Voltage Stall Prevention Operation Level Operation level is fixed, presence or absence can be selected
Fast-Response Current Limit Level Operation level is fixed, presence or absence can be selected
Frequency Setting Analog Input 0 to 5VDC, 0 to 10VDC, 4 to 20mADC
Signal Digital Input Entered from control panel (FR-PA02-02)
Starting Signal Forward and reverse rotation, start signal automatic self-holding input (3-wire input) can be selected
Alarm Reset Used to reset alarm output provided when protective function is activated
Up to 15 speeds can be selected. (Each speed can be set between 0 and 400Hz, running speed can be changed
Multi-Speed Selection
during operation from the control panel)
Used to select second functions (accel. time, decel. time, torque boost, freq., electronic overcurrent
Second Function Selection
protection)
Output Stop Instantaneous shut-off of inverter output (frequency, voltage)
Current Input Selection Used to select input of frequency setting signal 4 to 20mADC (terminal 4)
Use
Input Signals
Start Signal Automatic Self-Holding Selection Used to select start signal automatic self-holding input(3-wire input) Pr. 180
External Thermal Relay Input Thermal relay contact input for use when the inverter is stopped by the external thermal relay to
Pr. 183
PU Operation-External Operation Switching Used to switch between PU operation and external operation from outside the inverter
for
V/F-General-Purpose Magnetic Flux Switching Used to switch between V/F control and general-purpose magnetic flux vector from outside the inverter selection.
Maximum/minimum frequency setting, frequency jump operation, external thermal relay input
selection, automatic restart operation after instantaneous power failure, forward/reverse rotation
Operation Functions
prevention, slip comp., operation mode selection, off-line auto tuning function, PID control, computer
link operation (RS-485)
2 open collector output signals can be selected from inverter running, up to frequency, frequency detection,
overload alarm, zero current detection, output current detection, PID upper limit, PID lower limit, PID forward/
Operation Status
reverse rotation, operation ready, minor fault and alarm, and 1 contact output (230VAC 0.3A, 30VDC 0.3A)
Output Signals can be selected
1 signal can be selected from output frequency, motor current and output voltage. Pulse train output
For Meter
(1440 pulses/second/full scale)
Operating Status Output voltage, output current, set frequency, running
Display
412
E500 Series Terminal Connection Diagram Terminal Block Layout
MCCB MC Motor 600V class
3-phase AC R(L 1) U RH A
V IM
power supply S(L2) W RM B
T(L 3 ) Ground
24VDC power output and RL C
external transistor common PC P1 Jumper MRS 10
Note 4 Remove this jumper when RES 2
(+)P
using the optional power-factor SD 5
PR improving DC reactor. AM 4
Forward rotation start STF
(-)N PC SD
Brake resistor connection
Reverse rotation start STR SE STF
High RH RUN STR
Multi-speed selection A FU SD
Middle RM
B Alarm
Low RL
output
Output stop MRS C
Reset RES
Contact input common SD RUN Running
Note 3
FU Frequency detection Open
Control input signals
(No voltage input allowed) SE Open collector output common collector outputs
Note 2 Sink/source common
Frequency setting signals (Analog)
(Note 1) 3 10(+5V)
Frequency 2
2 0 to 5VDC Selected
setting 0 to 10VDC
potentiometer 1 5(Common)
1/2W1kΩ Current input(-) Note 3
SD
4 to 20mADC(+) 4(4 to 20mADC) Note 2
AM (+) Analog signal
When using current input as the output
frequency setting signal, set "4" in 5 (- )
any of Pr.180 to Pr.183 (input (0 to 10VDC)
terminal function selection) and PU connector Ground Main circuit terminal
assign AU (current input selection) (RS-485) Control circuit input terminal
to any of terminal RH, RM, RL, or
MRS, then turn the AU signal on. Control circuit output terminal
Notes:
1. If the potentiometer is to be operated often use a 2W1kΩ potentiometer.
2. Terminals SD and SE are electrically isolated.
3. Terminals SD and 5 are common. Do not connect them to each other or to ground.
4. To avoid damage to the VFD, do not allow a short circuit between terminals PC and SD. If they are shorted, the VFD will be damaged
Voltage
Horsepower
414
F700 Ratings 480V Class
Input: 1 Phase / 3 Phase • Output Voltage: 3 Phase 380-480V at 50/60Hz
Voltage Tolerance: 323-528V at 50/60Hz • Available Braking Torque: 15% Torque Continuous
SLD (40°C) LD
Input: 1 Phase / 3 Phase • Output Voltage: 3 Phase 380-480V at 50/60Hz • Voltage Tolerance: 323-550V at 50/60Hz
Available Braking Torque: 15% Torque Continuous • DC Link Choke is Included With The VFD
SLD (40°C) LD
0.015Hz/0 to 60Hz (terminal 2, 4: 0 to 10V/12bit); 0.03Hz/0 to 60Hz (terminal 2, 4: 0 to 5V/11bit, 0 to 20mA/approx. 11bit,
Frequency Setting Analog Input
terminal 1: -10V to +10V/11bit); 0.06Hz/0 to 60Hz (terminal 1: 0 to ±5V/10bit)
Resolution
Control Specifications
Frequency Analog Input Within ±0.2% of the max. output frequency (25°C ± 10°C)
Accuracy Digital Input Within 0.01% of the set output frequency
Voltage/Frequency Characteristics Base frequency can be set from 0 to 400Hz. Constant torque/variable torque pattern or adjustable 5 points V/F can be selected
Starting Torque 120% (3Hz) when set to simple magnetic flux vector control and slip compensation
Acceleration/Deceleration
0 to 3600s (acceleration and deceleration can be set individually), linear or S-pattern acceleration/deceleration mode can be selected.
Time Setting
DC Injection Brake Operation frequency (0 to 120Hz), operation time (0 to 10s), operation voltage (0 to 30%) variable
Stall Prevention Operation Level Operation current level can be set (0 to 150% adjustable), whether to use the function or not can be selected
Frequency Setting Analog Input Terminal 2, 4: 0 to 10V, 0 to 5V, 4 to 20mA can be selected. Terminal 1: -10 to +10V, -5 to 5V can be selected.
Signal Digital Input Four-digit BCD or 16-bit binary using the setting dial of the operation panel (when used with the option FR-A7AX)
Start Signal Available individually for forward and reverse rotation. Start signal automatic self-holding input (3-wire input) can be selected.
Select any twelve signals using Pr.178 to Pr.189 (input terminal function selection) from among multi-speed selection, second func-
tion selection, terminal 4 input selection, JOG operation selection, selection of automatic restart after instantaneous power failure,
external thermal relay input, HC connection (inverter operation enable signal), HC connection (instantaneous power failure detection),
Input Signals
PU operation/external interlock signal , PID control enable terminal, PU operation, external operation switchover, output stop, start
self-holding selection, forward rotation command, reverse rotation command, inverter reset, PTC thermistor input, PID forward reverse
operation switchover, PU-NET operation switchover, NET-external operation switchover, command source switchover.
Operation Specifications
Max. and min. frequency settings, frequency jump operation, external thermal relay input selection, polarity reversible operation, automatic
Operational Functions restart after instantaneous power failure operation, continuous operation at an instantaneous power failure, commercial power supply,
inverter switchover operation, forward/reverse rotation prevention, operation mode selection, PID control, computer link operation (RS-485).
Select any seven signals using Pr.190 to Pr.196 (output terminal function selection) from among inverter running, up-to-speed, instanta-
neous power failure/undervoltage, overload warning, output frequency detection, second output frequency detection, electronic thermal
relay function pre-alarm, PU operation mode, inverter operation ready, output current detection, zero current detection, PID lower limit,
PID upper limit, PID forward rotation reverse rotation output, commercial power supply-inverter switchover MC1, commercial power
Operating Status supply-inverter switchover MC2, commercial power supply-inverter switchover MC3, fan fault output, heatsink overheat pre-alarm, inverter
Output running start command on, deceleration at an instantaneous power failure, PID control activated, during retry, during PID output suspen-
Signals sion, life alarm, input MC stop signal, power savings average value update timing, current average monitor, alarm output 2, maintenance
timer alarm, remote output, minor failure output, alarm output. Open collector output (5 points), relay output
(2 points) and alarm code of the inverter can be output (4 bit) from the open collector.
When Used With The Select any seven signals using Pr. 313 to Pr. 319 (extension output terminal function selection) from among control circuit
FR-A7AY (Option) capacitor life, main circuit capacitor life, cooling fan life, inrush current limit circuit life.
Select from output frequency, motor current (steady or peak value), output voltage, frequency setting value, running speed, converter
output voltage (steady or peak value), electronic thermal relay function load factor, input power, output power, load meter, reference
Analog Output
voltage output, motor load factor, energy saving effect, PID set value, PID process value using Pr. 54 “CA terminal function selection
(analog current output)” and Pr. 158 “AM terminal function selection (analog output)”.
Output frequency, motor current (steady or peak value), output voltage, alarm indication, frequency setting, running speed, converter out-
put voltage (steady or peak value), electronic thermal load factor, input voltage, output voltage, road meter, cumulative energization time,
Operating Status actual operation time, motor load factor, cumulative energization power, power saving effect, cumulative saving power, PID set point, PID
Parameter process value, PID deviation value, inverter I/O terminal monitor, input terminal option monitor (*1), output terminal option monitor (*1),
Display
Unit (FR- option fitting status monitor (*2), terminal assignment status (*2)
DU07/
FR-PU04) Alarm definition is displayed when the protective function is activated, the output voltage/current/frequency/cumulative energization time
Alarm Definition
right before the protection function was activated and the past 8 alarm definitions are stored.
Interactive Guidance Operation guide/troubleshooting with a help function. (*2)
Overcurrent during acceleration, overcurrent during constant speed, overcurrent during deceleration, overvoltage during acceleration,
overvoltage during constant speed, overvoltage during deceleration, inverter protection thermal operation, heatsink overheat, instanta-
neous power failure occurrence, undervoltage, input phase failure, motor overload, output side earth (ground) fault overcurrent, output
phase failure, external thermal relay operation, PTC thermistor operation, option alarm, parameter error, PU disconnection, retry count
Protective/Warning Function
excess, CPU alarm, power supply short for operation panel, 24VDC power output short, output current detection value over, inrush resis-
tance overheat, communication alarm (inverter), analog input alarm, internal circuit alarm (15V power supply), fan fault, overcurrent stall
prevention, overvoltage stall prevention, electronic thermal prealarm, PU stop, maintenance timer alarm (*1), parameter write error, copy
operation error, operation panel lock.
Ambient Temperature -10°C to +50°C (non-freezing)
Environment
416
F700 Series Terminal Connection Diagram
A1 B1 C1 A2 B2 C2 10E 10 2 5 4
418
F700 Series Options Instruction Manuals
Stocked
Description Model Number
Item
FR-F700 Installation Manual - Contains instructions
Conduit Attachments for installer and parameter list. (Included with VFD, IB(NA)0600218 -
plus CD with all versions of VFD and option manuals.)
Drive Model Length Weight Stocked
Model Number FR-F700-NAPLC Function Programming Manual IB(NA)0600420 -
F720 (*1) F740 (*1) (in) (*4) (lbs) Item
FR-A7FN05 (*3) 01250 - 5.9 5 - FR-F700 Basic Manual - Contains wiring details, VFD
IB(NA)0600216 -
FR-A7FN06 (*3) 01540 00770 6.2 5 S layout drawings, alarm definitions and parameter list.
FR-A7FN07 (*3) 01870, 02330 00930, 01160 9 15 S FR-F700 Applied Manual - Contains wiring details,
FR-A7FN-10 (*2) - 01800 24 37 S VFD layout drawings, alarm definitions and complete IB(NA)0600217 -
parameter list with definitions and setting examples.
FR-A7FN-11 (*2) - 02160, 02600 24 41 S
03160, 03800, FR-PU07 Manual - Contains complete instruction
FR-A7FN-12 (*2) 03250, 03610 24 45 S IB(NA)0600240 -
04750 sets and screen definitions.
FR-A7FN-13 (*2) - 04320, 04810 26 50 S Manuals available for download at www.meau.com
05470, 06100,
FR-A7FN-14 (*2) - 26 64 S
06830
Notes: Parameter Units / Parameter Copy Units
1. For FR-F700s smaller than listed above, they are UL Type 1, and conduit attachment is standard.
2. Mounting hardware included for standard DC chokes which ship with VFD. Kits are powder coated
Parameter units are used for operator control, reading and
similar to VFD, charcoal gray. writing parameters, and drive monitoring. Parameter Copy
3. Kits are coated zinc clear. Units also read the drive parameter settings and copy them into
4. Width and depth of kit match the associated VFD.
non-volatile memory, and can write them into other drives.
Stocked
Model Number Description
External Heatsink Attachment Item
FR-CB201 Extension cable straight plugs on both ends - 1M S
Model Number Drive Model
Stocked Item FR-CB203 Extension cable straight plugs on both ends - 3M S
(*1) F720 F740
FR-CB205 Extension cable straight plugs on both ends - 5M S
FR-A7CN01 00105 to 00250 00023 to 00126 S
FR-DU07 Control Panel for F700 S
FR-A7CN02 00340, 00490 00170, 00250 S LCD Multi-lingual Parameter Copy Unit (English,
FR-A7CN03 00630 00310, 00380 S French, Spanish, German, Italian, Swedish, Finnish,
FR-A7CN04 00770 to 01250 00470, 00620 S FR-PU07 Japanese) for operator control, parameter read/write and S
monitoring. Stores settings in non-volatile memory.
FR-A7CN05 01540 - S Built-in parameter copy capability. (F/A700 based)
FR-A7CN06 - 00770 S FR-PU07-01 PU07 with hand/auto and enhanced display functions S
FR-A7CN07 01870, 02330 00930, 01160, 01800 S FR-ADP FR-DU07 panel mounting adapter S
FR-A7CN08 - 02160 - LCD Multi-lingual Parameter Copy Unit (English, French,
FR-A7CN09 - 02600 - FR-PU04 Spanish, German, Italian, Swedish, Finnish, Japanese) for S
operator control, parameter read/write and monitoring.
FR-A7CN10 03160, 03800, 04750 03250, 03610 -
SC-FRPC Serial Communication Cable S
Note: FR-PU07BB-L Battery powered PU07 S
1. Kits are coated zinc clear.
FR-RJ45-HUB4 Serial network hub - 2 stations -
FR-RJ45-HUB10 Serial network hub - 8 stations -
Option Cards FR-RJ45-TR Terminating resistor for FR-RJ45-HUB -
CC-Link FR-A7NC S
Communication
Modbus TCP X - X -
Gateway
FR-PU07BB-L - - 2a 2a
FR-PA07 - 2a 2a 2a
Software FR-CONFIGURATOR 3 3 3 3
420
Braking Torque (%) at Short-Time Rating of 30 Sec. for 5HP and Less
Braking Torque (%) at Short-Time Rating of 15 Sec. for 7.5HP and Larger
240V Series
Motor Capacity
Braking HP 7.5 10 15 20 25 30 40 50 60 75
Torque kW 5.5 7.5 11 15 18.5 22 30 37 45 55
100% For Brake Unit UFS22J UFS40J 2 x UFS40J
15 Secs. Brake Resistor RUFC15J RUFC22J RUFC40J 2 x RUFC40J
Continuous Permissible Power (W) UFS22J - 1500W UFS40J - 2000W 2ea x UFS40J - 4000W
Electrical
Resistance (Overall) RUFC15J - 24ohms RUFC22J - 12ohms RUFC40J - 7.5ohms 2ea x RUFC40J - 3.75ohms
Data
Continuous Current (Amps) 7A 10A 14.6A 29.2A
460V Series
Motor Capacity
Braking HP 7.5 10 15 25 30 40 50 60 75
Torque kW 5.5 7.5 11 18.5 22 30 37 45 55
100% For Brake Unit UFS22 UFS40
15 Secs. Brake Resistor RUFC15/480 RUFC22/480 RUFC40/480
Continuous Permissible Power (W) UFS22 - 2000W UFS40 - 4000W
Electrical
Resistance (Overall) RUFC15/480 - 44ohms RUFC22/480 - 27ohms RUFC40/480 - 15ohms
Data
Continuous Current (Amps) 6A 7.7A 14.6
Motor Capacity
Braking HP 100 125 150 175 215 300 375
Torque kW 75 90 110 132 160 220 280
100% For Brake Unit UFS110 2 X UFS110
15 Secs. Brake Resistor RUFC110/480 2 X RUFC110/480
Continuous Permissible Power (W) UFS110 - 8000W 2 x UFS110 - 16000W
Electrical
Resistance (Overall) RUFC110/480 - 6.8ohms 2 x RUFC110/480 - 3.4ohms
Data
Continuous Current (Amps) 30.7A 61.4A
Dimensions
Approximate
Height Width Depth Stocked
Model Number Weight
Item
mm inches mm inches mm inches kg lbs
UFS20J S
250 9.8 175 6.9 2.5 5.5
UFS40J S
240V RUFC15J 240 9.5 100 3.9 2.8 6.2 S
RUFC22J 310 12.2 75 3 3.5 7.7 S
RUFC40J 365 14.4 4.3 9.5 S
UFS22 S
100 3.9 175 6.9 2.5 5.5
UFS40 250 9.8 S
UFS110 107 4.2 195 7.7 3.9 8.6 S
480V RUFC15/480 310 12.2 3.5 7.7 S
100 3.9 75 3
RUFC22/480 365 14.4 4.2 9.3 S
RUFC40/480 2 x 365 2 x 14.4 2 x 100 2 x 3.9 2 x 75 2x3 8.7 19.2 S
RUFC110/480 4 x 365 4 x 14.4 4 x 100 4 x 3.9 4 x 75 4x3 17.3 38.1 S
422
F700 VFD Efficiency Values
240VAC 3-Phase Input 480VAC 3-Phase Input
Rated Watts Efficiency Watts Efficiency Rated Watts Efficiency Watts Efficiency
Model Number Model Number
Watts Loss SLD SLD Loss LD LD Watts Loss SLD SLD Loss LD LD
FR-F720-00046-NA 750 70 91% 60 92% FR-F740-00023-NA 750 60 92% 50 93%
FR-F720-00077-NA 1500 110 93% 100 93% FR-F740-00038-NA 1500 80 95% 80 95%
FR-F720-00105-NA 2200 140 94% 130 94% FR-F740-00052-NA 2200 100 95% 90 96%
FR-F720-00167-NA 3700 210 94% 190 95% FR-F740-00083-NA 3700 160 96% 140 96%
FR-F720-00250-NA 5500 300 95% 260 95% FR-F740-00126-NA 5500 190 97% 180 97%
FR-F720-00340-NA 7500 370 95% 340 95% FR-F740-00170-NA 7500 240 97% 220 97%
FR-F720-00490-NA 11000 590 95% 530 95% FR-F740-00250-NA 11000 340 97% 310 97%
FR-F720-00630-NA 15000 660 96% 580 96% FR-F740-00310-NA 15000 390 97% 350 98%
FR-F720-00770-NA 18500 910 95% 810 96% FR-F740-00380-NA 18500 490 97% 440 98%
FR-F720-00930-NA 22000 1050 95% 940 96% FR-F740-00470-NA 22000 580 97% 520 98%
FR-F720-01250-NA 30000 1540 95% 1370 95% FR-F740-00620-NA 30000 810 97% 710 98%
FR-F720-01540-NA 37000 1490 96% 1320 96% FR-F740-00770-NA 37000 1000 97% 930 97%
FR-F720-01870-NA 45000 1680 96% 1490 97% FR-F740-00930-NA 45000 1170 97% 1030 98%
FR-F720-02330-NA 55000 2210 96% 1950 96% FR-F740-01160-NA 55000 1510 97% 1320 98%
FR-F720-03160-NA 75000 2825 96% 2500 96% FR-F740-01800-NA 75000 2700 96% 2250 97%
FR-F720-03800-NA 90000 3165 96% 2800 96% FR-F740-02160-NA 90000 3300 96% 2700 97%
FR-F720-04750-NA 110000 4070 96% 3600 96% FR-F740-02600-NA 110000 3960 96% 3300 97%
- - - - - - FR-F740-03250-NA 132000 4800 96% 3960 97%
- - - - - - FR-F740-03610-NA 160000 5550 97% 4800 97%
- - - - - - FR-F740-04320-NA 185000 6600 96% 5550 97%
- - - - - - FR-F740-04810-NA 220000 7500 97% 6600 97%
- - - - - - FR-F740-05470-NA 250000 8400 97% 7500 97%
- - - - - - FR-F740-06100-NA 280000 9450 97% 8400 97%
- - - - - - FR-F740-06830-NA 315000 10650 97% 9450 97%
- - - - - - FR-F740-07700-NA 355000 12000 97% 10650 97%
- - - - - - FR-F740-08660-NA 400000 13500 97% 12000 97%
- - - - - - FR-F740-09620-NA 450000 15000 97% 13500 97%
- - - - - - FR-F740-10940-NA 500000 16800 97% 15000 97%
- - - - - - FR-F740-12120-NA 560000 18900 97% 16800 97%
General Notes:
1. The amount of heat generated by the inverter is based on one inverter connected to one motor of the same capacity.
2. The amount of heat generated in the above table is the amount of heat generated when the inverter is operated at its rated current.
3. The amount of heat generated will decrease according to the motor load and usage (duty).
4. When using the external heat sink attachment watt loss decreases by 60%.
• Wide speed range: 200:1 operating range is • Brake Transistor Circuit: Included in all sizes
possible - even when the drive is used ‘open loop’ up to 30 Hp
• PLC feature: A700 programmability provides true • Integral Radio Filter: Limits Radio Noise
intelligence inside the drive - a simple emissions to meet EU Directive - all sizes of drive
solution for complex applications • Speed control: with or without torque limit allows
• Easy gain tuning: Compensates automatically for 200:1 Speed range, driving or overhauling
changes in load inertia to ensure smooth and • Open Loop Torque Control: including torque at
consistent operation zero speed
• Fast response: Up to 300 radians / second speed • UL Listed for single-phase input
response means lightning fast reaction to sudden
load changes
• USB port: Allows simple connection to the new
FR-Configurator Software for quick and easy
commissioning Voltage
• Power down braking: Keeps the motor under
control even if the supply power is lost 240 3/4 – 200 Hp
• Remote I/O capability: All of the drive I/O can be
read or controlled over a network 480 3/4 – 800 Hp
600 1 – 650 Hp
Horsepower
424
A700 Ratings 480V Class
Output voltage: 3 phase 380-480V at 60Hz - Voltage Tolerance 323-528V at 60Hz.
ND (50°C) HD (50°C) LD (50°C) SLD (40°C) Regenerative
150% OL / 1 min 200% OL / 1 min 120% OL / 1 min 110% OL / 1 min Braking Torque
Frame Cooling Protective
Model Number (*6) / Max Value Stocked Item
200% OL / 3 sec 250% OL / 3 sec 150% OL / 3 sec 120% OL / 3 sec Size Method Rating
(Permissible
Hp (*1) FLA Hp (*1) FLA Hp (*1) FLA Hp (*1) FLA Duty)
Notes:
1. Motor ratings shown are intended as guidelines only - based on 4 pole standard inductions motors.
2. UL Type 1 version drives are available - replace “-NA” suffix with “-N4”.
3. Conduit adapter option required for types 01150 - 03460.
4. Conduit adapter option required for types 00570 - 05470.
5. Depth is slightly extended to meet UL Type 1 requirements.
6. For single phase input, derate output current by 40% (Models up to FR-A720-02880-NA and FR-A740-03610-NA)
426
A700 Terminal Connection Diagram
A1 B1 C1 A2 B2 C2 10E 10 2 5 4
second function selection, third function selection, terminal 4 input selection, JOG operation selection, selection of automatic restart after instantaneous
power failure, flying start, external thermal relay input, inverter operation enable signal (FR-HC/FR-CV connection), FR-HC connection (instantaneous
power failure detection), PU operation/external inter lock signal, external DC injection brake operation start, PID control enable terminal, brake opening
Input Signal completion signal, PU operation/external operation switchover, load pattern selection forward rotation reverse rotation boost, V/F switching, load torque
high-speed frequency, S-pattern acceleration/deceleration C switchover, pre-excitation, output stop, start self-holding selection, control mode changing,
torque limit selection, start-time tuning start external input, torque bias selection 1, 2 (*1), P/PI control switchover, forward rotation command, reverse
rotation command, inverter reset, PTC thermistor input, PID forward reverse operation switchover, PU-NET operation switchover, NET-external operation
switchover, and command source switchover, conditional position pulse train sign (*1), conditional position droop pulse clear (*1).
Pulse Train Input 100kpps
Maximum/minimum frequency setting, frequency jump operation, external thermal relay input selection, polarity reversible operation, automatic
restart after instantaneous power failure operation, commercial power supply-inverter switchover operation, forward/reverse rotation prevention,
remote setting, brake sequence, second function, third function, multi-speed operation, original operation continuation at instantaneous power
Operational Functions failure, stop-on-contact control, load torque high speed frequency control, droop control, regeneration avoidance, slip compensation, operation
mode selection, offline auto tuning function, online auto tuning function, PID control, computer link operation (RS-485), motor end orientation
(*1), machine end orientation (*1), pre-excitation, notch filter, machine analyzer (*1), easy gain tuning, speed feed forward, and torque bias (*1)
Select any signals using Pr. 190 to Pr. 196 (output terminal function selection) from among inverter running, up-to-frequency, instantaneous
power failure/undervoltage, overload warning, output frequency (speed) detection, second output frequency (speed) detection, third output
frequency (speed) detection, regenerative brake prealarm, electronic thermal relay function pre-alarm, PU operation mode, inverter operation
ready, output current detection, zero current detection, PID lower limit, PID upper limit, PID forward rotation reverse rotation output, commercial
power supply-inverter switchover MC1, commercial power supply-inverter switchover MC2, commercial power supply-inverter switchover MC3,
Operating orientation completion (*1), brake opening request, fan fault output, heatsink overheat pre-alarm , inverter running/start command on, deceleration
Status
Output at an instantaneous power failure, PID control activated, during retry, PID output interruption, life alarm, alarm output 1, 2, 3 (power-off signal),
Signals power savings average value update timing, current average monitor, maintenance timer alarm, remote output, forward rotation output (*1),
reverse rotation output (*1), low speed output, torque detection, regenerative status output (*1), start-time tuning completion, in-position
completion (*1), minor failure output and alarm output. Open collector output (5 points), relay output (2 points) and alarm code of the inverter
can be output (4 bit) from the open collector.
Using FR-A7AY, In addition to the above, select any signals using Pr. 313 to Pr. 319 (extension output terminal function selection) from among control circuit
FR-A7AR capacitor life, main circuit capacitor life, cooling fan life, inrush current limit circuit life (only positive logic can be set for extension terminals of the
(optional) FR-A7AR).
Pulse Train Input 500kpps
Select any signals using Pr. 54 FM terminal function selection (pulse train output) and Pr. 158 AM terminal function selection (analog output) from
among output frequency, motor current (steady or peak value), output voltage, frequency setting, operation speed, motor torque, converter output
Pulse / Analog Output voltage (steady or peak value), electronic thermal relay function load factor, input power, output power, load meter, motor excitation current,
reference voltage output, motor load factor, power saving effect, regenerative brake duty, PID set point, PID measured value, motor output, torque
command, torque current command, and torque monitor.
Output frequency, motor current (steady or peak value), output voltage, frequency setting, running speed,motor torque, overload, converter
output voltage (steady or peak value), electronic thermal relay function load factor, input power, output power, load meter, motor excitation
Operating current, cumulative energization time, actual operation time, motor load factor, cumulative power, energy saving effect, cumulative saving power,
PU (FR- Status regenerative brake duty, PID set point, PID measured value, PID deviation, inverter I/O terminal monitor, input terminal option monitor (*2), output
Indication
DU07 / terminal option monitor (*2), option fitting status (*3), terminal assignment status (*3), torque command, torque current command, feed back
FR-PU07 / pulse (*1), motor output
FR-PU04) Alarm Alarm definition is displayed when the protective function is activated, the output voltage/current/frequency/cumulative energization time right
Definition before the protection function was activated and past 8 alarm definitions are stored.
Interactive Operation guide/trouble shooting with a help function (*3)
Guidance
Overcurrent during acceleration, overcurrent during constant speed, overcurrent during deceleration, overvoltage during acceleration, overvoltage
during constant speed, overvoltage during deceleration, inverter protection thermal operation, motor protection thermal operation, heatsink
overheat, instantaneous power failure occurrence, undervoltage, input phase failure, motor overload, output side earth (ground) fault overcurrent,
output short circuit, main circuit element overheat, output phase failure, external thermal relay operation, PTC thermistor operation, option alarm,
parameter error, PU disconnection, retry count excess, CPU alarm, operation panel power supply short circuit, 24VDC power output short circuit,
Protective / Warning Function output current detection value excess, inrush current limit circuit alarm, communication alarm (inverter), USB error, opposite rotation deceleration
error, analog input error, fan fault, overcurrent stall prevention, overvoltage stall prevention, regenerative brake prealarm, electronic thermal relay
function prealarm, PU stop, maintenance timer alarm (*2), brake transistor alarm, parameter write error, copy operation error, operation panel
lock, parameter copy alarm, speed limit indication, encoder no-signal (*1), speed deviation large (*1), overspeed (*1), position error large (*1),
encoder phase error (*1)
Ambient Temperature -10°C to +50°C (non-freezing)
Environment
428
A700 Options Instruction Manuals
Description Model Number
FR-A700 Installation Manual - Contains instructions for
Function / Options installer and parameter list. (Included with VFD, plus CD with IB(NA)0600254
all versions of VFD and option manuals.)
Model No. Stocked Item FR-A700 Basic Manual - Contains wiring details, VFD
IB(NA)0600225
120VAC Control Input FR-A7AC S layout drawings, alarm definitions and parameter list.
Analog I/O FR-A7AN S FR-A700 Applied Manual - Contains wiring details, VFD layout
drawings, alarm definitions and complete parameter list with IB(NA)0600255
Encoder Feedback FR-A7AP S
definitions and setting examples.
Encoder Pulse Dividing Output FR-A7AL S
FR-A700 PLC Programming Manual - Contains
Relay Output FR-A7AR S IB(NA)0600262
Function
Communication
Modbus TCP X - X -
Gateway
EtherNet/IP FR-A7NE S
PROFINET IO X - X -
LonWorks FR-A7NL S
BACnet MS/TP (*5) - X X X
Profibus DP FR-A7NP S
Metasys N2 - X X X
SSCNET III FR-A7NS S Siemens FLN - X - -
Stocked Item S S - -
Notes:
For additional information, visit www.iccdesigns.com
External Heatsink Attachment 1. Physically mounts within VFD and powered by VFD
2. FR-E7TR option recommended. (PU connector not available for use)
Drive Model Model Stocked 3. Communication to multiple VFD’s is possible
A720 A740 A760 Number Item 4. Mounted and powered external to VFD
5. BACnet MS/TP is built in to F700. Gateway required for pre August 2010 production.
00017, 00040,
00080 to 00175 00025 to 00090 FR-A7CN01 S
00061
00240, 00330 00120, 00170 00120 FR-A7CN02 S
00460 00230, 00310 00220 FR-A7CN03 S Conduit Attachments
00610 to 00900 00380, 00440 00330 FR-A7CN04 S Drive Model Length
Weight Stkd.
01150 - FR-A7CN05 S Model Number A720 A740 A760 (in)
(lbs) Item
00570 - FR-A7CN06 S (*1, *2) (*1, *2) (*1, *2) (*5)
01450, 01750 00710 to 01100 00550, 00840 FR-A7CN07 S FR-A7FN05 (*4) 00900 - - 5.9 5 -
01040, 01310, FR-A7FN06 (*4) 01150 00570 - 6.2 5 S
01440 FR-A7CN08 -
01520
01450, 00710 to 00550,
01800 - FR-A7CN09 - FR-A7FN07 (*4) 9 15 S
01750 01100 00840
03160, 03800,
02160, 02600 - FR-A7CN10 - 01440, 01040 to
04750 FR-A7FN-11 (*3) - 24 41 S
01800 01520
02150 - FR-A7CN11 -
02880, 02160,
FR-A7FN-12 (*3) - 24 45 S
03460 02600
03250, 02210,
Software FR-A7FN-13 (*3) -
03610 02550
26 50 S
Model Number Description Stocked Item 04320 to
FR-A7FN-14 (*3) - 03040 26 64 S
FR-CONFIGURATOR Programming and diagnostic software S 05470
Notes:
1. FR-A720-00460 to 00760 & FR-A740-00230 to 00440 are UL Type 1: the conduit adapter is
included as standard.
2. FR-A700 smaller than listed above, the UL Type 1 version (conduit adapter standard) is a
A700 Demonstration Unit special type: Change from suffix -NA to -N4.
3. Mounting hardware included for standard DC chokes which ship with VFD. Kits are powder
Model Stocked coated similar to VFD charcoal gray.
Description 4. Kits are coated zinc clear.
Number Item
5. Width and depth of kit match the asscociated VFD
VFD-A700- Includes A720 1/2HP, pre-wired digital input switches, LED out-
S
DEMO puts, two potentiometers, analog meter and encoder option
VFD-MOTOR- Includes 1/2HP motor and encoder with quick connections to
S
ENC-DEMO VFD-A700-DEMO
430
A700 Dynamic Braking
All Mitsubishi Electric VFD’s have some inherent braking capability. During controlled deceleration, motor regenerative losses are
dissipated in the motor, wire, and VFD circuitry. The built-in DC injection braking allows for low speed braking and stopping.
When the above capabilities are inadequate for an application, it is necessary to add a power transistor brake unit and resistor unit in
series across the DC bus.
Motor regeneration causes the DC bus voltage to increase, and when the voltage exceeds a specified threshold, the transistor turns on to
pass current through the resistor. Motor kinetic energy is converted to heat energy. VFD overcurrent and overvoltage protective circuits are
active at all times, and will fault-trip the VFD if the brake size is inadequate.
Two main factors must be considered when sizing the brake, the effective duty cycle (%ED) and the short time duty rating. The
effective duty cycle is increased when an external resistor is added. It is preferable to profile the effective duty cycle of the units of time.
With this information, the short time duty is known and the %ED can be calculated, as shown in the below example.
%ED = Braking time / total time for complete operating cycle x 100
Instruction Manuals
Model Model Number Stocked Item
FR-ABR(H) IB(NA)66891 -
FR-BU2 IB(NA)0600292 -
FR-BU2-C IB(NA)0600379 -
UFS NT348E05 -
Braking Torque (%) at Short-Time Rating of 30 Sec. for 5HP and Less
Braking Torque (%) at Short-Time Rating of 15 Sec. for 7.5HP and Larger
Stocked Brake Resistor Stocked Motor Capacity (HP)
Brake Unit Model Number
Item Model Number Item 1 2 3 5 7.5 10 15 20 25 30 40 50 60 75
FR-BU2-1.5K S BU-1500-TEIKOUKI - 100% 50% - - - - - - - - - - - -
FR-BU2-3.7K S BU-3700-TEIKOUKI - - 100% 50% 50% - - - - - - - - - -
FR-BU2-7.5K S BU-7.5K-TEIKOUKI - - - 100% 100% - - - - - - - - - -
230V
FR-BU2-15K S FR-BR-15K-UL S - - - - 280% 200% 120% 100% 80% 70% - - - -
FR-BU2-30K S FR-BR-30K-UL S - - - - - - 260% 180% 160% 130% 100% 80% 70% -
FR-BU2-55K - FR-BR-55K-UL - - - - - - - - - 300% 250% 180% 150% 120% 100%
FR-BU2-H15K S FR-BR-H15K-UL S - - - - 280% 200% 120% 100% 80% 70% - - - -
460V FR-BU2-H30K S FR-BR-H30K-UL S - - - - - - 260% 180% 160% 130% 100% 80% 70% -
FR-BU2-H55K S FR-BR-H55K-UL S - - - - - - - - 300% 250% 180% 150% 120% 100%
FR-BR-C3.7K - - - 170% 100% - - - - - - - - - -
FR-BU2-C22K S FR-BR-C7.5K - - - 340% 200% 130% 100% - - - - - - - -
600V FR-BR-C22K - - - - - - 300% 200% 145% 120% 100% - - - -
2 x FR-BU2-C22K S 2 x FR-BR-C22K - - - - - - - - - - - - 120% - -
3 x FR-BU2-C22K S 3 x FR-BR-C22K - - - - - - - - - - - - - - 120%
Note: FR-BU2-C22K is not UL or cUL listed for use with the FR-BR-C resistor. If UL or cUL is required, use the ASC-RES-C22K in place of FR-BR-C22K.
432
Dynamic Braking Unit & Resistor Specifications
Continuous
Weight Resistance
Brake Unit Model Number Stocked Item Brake Resistor Model Number Stocked Item Rated (Watts) Permissible
kg / lbs (Ohms)
Power (Watts)
FR-BU2-1.5K S BU-1500-TEIKOUKI - n/a 50 300 100
FR-BU2-3.7K S BU-3700-TEIKOUKI - n/a 30 900 300
FR-BU2-7.5K S BU-7.5K-TEIKOUKI - n/a 20 1800 600
230V
FR-BU2-15K S FR-BR-15K-UL S 15 / 33 8 4000 990
FR-BU2-30K S FR-BR-30K-UL S 30 / 66 4 8000 1990
FR-BU2-55K - FR-BR-55K-UL - 70 / 154 2 16000 3910
FR-BU2-H7.5K S 2 x BU-3700-TEIKOUKI - n/a 60 1800 600
FR-BU2-H15K S FR-BR-H15K-UL S 15 / 33 32 4000 990
460V FR-BU2-H30K S FR-BR-H30K-UL S 30 / 66 16 8000 1990
FR-BU2-H55K S FR-BR-H55K-UL S 70 / 154 8 16000 3910
FR-BU2-H75K S MT-BR5-H75K - 70 / 154 6.5 30000 7500
240V Series
Motor Capacity
Braking Hp 7.5 10 15 20 25 30 40 50 60 75
Torque kW 5.5 7.5 11 15 18.5 22 30 37 45 55
100% for Brake Unit UFS22J UFS40J 2 x UFS40J
15 secs. Brake Resistor RUFC15J RUFC22J RUFC40J 2 x RUFC40J
Continuous Permissible Power (W) UFS22J - 1500W UFS40J - 2000W 2ea x UFS40J - 4000W
Electrical
Resistance (Overall) RUFC15J - 24ohms RUFC22J - 12ohms RUFC40J - 7.5ohms 2ea x RUFC40J - 3.75ohms
Data
Continuous Current (Amps) 7A 10A 14.6A 29.2A
460V Series
Motor Capacity
Braking Hp 7.5 10 15 25 30 40 50 60 75
Torque kW 5.5 7.5 11 18.5 22 30 37 45 55
100% for Brake Unit UFS22 UFS40
15 secs. Brake Resistor RUFC15/480 RUFC22/480 RUFC40/480
Continuous Permissible Power (W) UFS22 - 2000W UFS40 - 4000W
Electrical
Resistance (Overall) RUFC15/480 - 44ohms RUFC22/480 - 27ohms RUFC40/480 - 15ohms
Data
Continuous Current (Amps) 6A 7.7A 14.6A
Motor Capacity
Braking Hp 100 125 150 175 215 300 375
Torque kW 75 90 110 132 160 220 280
100% for Brake Unit UFS110 2 X UFS110
15 secs. Brake Resistor RUFC110/480 2 X RUFC110/480
Continuous Permissible Power (W) UFS110 - 8000W 2 x UFS110 - 16000W
Electrical
Resistance (Overall) RUFC110/480 - 6.8ohms 2 x RUFC110/480 - 3.4ohms
Data
Continuous Current (Amps) 30.7A 61.4A
Dimensions
Height Width Depth Approximate Weight Stocked
Model Number
mm inches mm inches mm inches kg lbs Item
UFS20J S
250 9.8 175 6.9 2.5 5.5
UFS40J S
240V RUFC15J 240 9.5 100 3.9 2.8 6.2 S
RUFC22J 310 12.2 75 3 3.5 7.7 S
RUFC40J 365 14.4 4.3 9.5 S
UFS22 S
100 3.9 175 6.9 2.5 5.5
UFS40 250 9.8 S
UFS110 107 4.2 195 7.7 3.9 8.6 S
480V RUFC15/480 310 12.2 3.5 7.7 S
100 3.9 75 3
RUFC22/480 365 14.4 4.2 9.3 S
RUFC40/480 2 x 365 2 x 14.4 2 x 100 2 x 3.9 2 x 75 2x3 8.7 19.2 S
RUFC110/480 4 x 365 4 x 14.4 4 x 100 4 x 3.9 4 x 75 4x3 17.3 38.1 S
434
A701 Series
Vector VFD with built-in Line Regeneration.
240V 7.5 – 75 Hp
Symbol Voltage Class Inverter capacity
A721 Three phase 240V class in kilowatts 480V 7.5 – 75 Hp
A741 Three phase 480V class 5.5K = 5.5KW
0.746kW = 1HP Horsepower
A701 Ratings
Note: There is no PLC function as included in the standard A700
Rating (CT & VT) IP00 Open Chassis Dimensions in inches (mm)
Weight Lbs (kg) Stocked Item
HP Rated Amps Model Number Height Width Depth
3-Phase 200~240VAC Input & Output
7 1/2 24 FR-A721-5.5K 18.5 (470) 9.9 (250) 10.7 (270) 44.1 (20) -
10 33 FR-A721-7.5K 18.5 (470) 9.9 (250) 10.7 (270) 48.5 (22) -
15 46 FR-A721-11K 21.6 (540) 11.9 (300) 11.6 (294) 72.7 (33) -
20 61 FR-A721-15K 21.6 (540) 11.9 (300) 11.6 (294) 77.1 (35) -
25 76 FR-A721-18.5K 23.7 (600) 15.4 (390) 12.6 (320) 110.2 (50) -
30 90 FR-A721-22K 23.7 (600) 15.4 (390) 12.6 (320) 114.6 (52) -
40 115 FR-A721-30K 27.6 (700) 17.8 (450) 13.4 (340) 152.0 (69) -
50 145 FR-A721-37K 27.6 (700) 18.5 (470) 14.5 (368) 191.7 (87) -
60 175 FR-A721-45K 27.6 (700) 18.5 (470) 14.5 (368) 198.3 (90) -
75 215 FR-A721-55K 35.5 (900) 23.7 (600) 16.0 (405) 264.4 (120) -
3-Phase 380~480VAC Input & Output
7 1/2 12 FR-A741-5.5K 18.5 (470) 9.9 (250) 10.7 (270) 55.1 (25) -
10 17 FR-A741-7.5K 18.5 (470) 9.9 (250) 10.7 (270) 57.3 (26) -
15 23 FR-A741-11K 21.6 (540) 11.9 (300) 11.6 (294) 81.5 (37) -
20 31 FR-A741-15K 21.6 (540) 11.9 (300) 11.6 (294) 88.1 (40) -
25 38 FR-A741-18.5K 23.7 (600) 14.2 (360) 12.6 (320) 105.8 (48) -
30 44 FR-A741-22K 23.7 (600) 14.2 (360) 12.6 (320) 108.0 (49) -
40 57 FR-A741-30K 27.6 (700) 17.8 (450) 13.4 (340) 143.2 (65) -
50 71 FR-A741-37K 27.6 (700) 18.5 (470) 14.5 (368) 176.3 (80) -
60 86 FR-A741-45K 27.6 (700) 18.5 (470) 14.5 (368) 182.9 (83) -
75 110 FR-A741-55K 35.5 (900) 23.7 (600) 16.0 (405) 253.3 (115) -
on-contact, second function selection, third function selection, terminal 4 input selection, JOG operation selection, selection of automatic restart after
instantaneous power failure, flying start, external thermal relay input, PU operation/external inter lock signal , external DC injection brake operation start, PID
control enable terminal, brake opening completion signal, PU operation/external operation switchover, load pattern selection forward rotation reverse rotation
Input Signal boost, V/F switching, load torque high-speed frequency, S-pattern acceleration/deceleration C switchover, pre-excitation, output stop, start self-holding
selection, control mode changing, torque limit selection, start-time tuning start external input, torque bias selection 1, 2 (*1), P/PI control switchover, forward
rotation command, reverse rotation command, inverter reset, PTC thermistor input, PID forward reverse operation switchover, PU-NET operation switchover,
NET-external operation switchover, and command source switchover, conditional position pulse train sign (*1), conditional position droop pulse clear (*1),
magnetic flux decay output shutoff.
Pulse Train Input 100kpps
Maximum/minimum frequency setting, frequency jump operation, external thermal relay input selection, polarity reversible operation, automatic
restart after instantaneous power failure operation, electronic bypass operation, forward/reverse rotation prevention, remote setting, brake sequence,
second function, third function, multi-speed operation, original operation continuation at instantaneous power failure, stop-on-contact control,
Operational Functions load torque high speed frequency control, droop control, regeneration avoidance, slip compensation, operation mode selection, offline auto tuning
function, online auto tuning function, PID control, computer link operation (RS-485), motor end orientation (*1), pre-excitation, notch filter, easy gain
tuning, speed feed forward, and torque bias (*1)
You can select any signals using Pr. 190 to Pr. 196 (output terminal function selection) from among inverter running, up-to-frequency, instantaneous
power failure/undervoltage, overload warning, output frequency (speed) detection, second output frequency (speed) detection, third output frequency
(speed) detection, electronic thermal relay function pre-alarm, PU operation mode, inverter operation ready, output current detection, zero current
detection, PID lower limit, PID upper limit, PID forward rotation reverse rotation output, electronic bypass MC1, electronic bypass MC2, electronic
Operating bypass MC3, orientation complete (*1), brake opening request, fan fault output, heatsink overheat pre-alarm , inverter running/start command on,
Status deceleration at an instantaneous power failure, PID control activated, during retry, PID output interruption, life alarm, fault output 1, 2, 3 (power-off
signal), power savings average value update timing, current average monitor, maintenance timer alarm, remote output, forward rotation output (*1),
Output reverse rotation output (*1), low speed output, torque detection, regenerative status output (*1), start-time tuning completion, in-position completion
Signals (*1), alarm output and fault output. Open collector output (5 points), relay output (2 points) and alarm code of the inverter can be output (4 bit) from
the open collector.
When used
with the In addition to the above, you can select any signals using Pr. 313 to Pr. 319 (extension output terminal function selection) from among control circuit
FR-A7AY, capacitor life, main circuit capacitor life, cooling fan life, inrush current limit circuit life. (only positive logic can be set for extension terminals of the
FR-A7AR FR-A7AR)
(optional)
Pulse Train Input 500kpps
Select any signals using Pr. 54 FM terminal function selection (pulse train output) and Pr. 158 AM terminal function selection (analog output)
from among output frequency, motor current (steady or peak value), output voltage, frequency setting, operation speed, motor torque, converter
Pulse / Analog Output output voltage (steady or peak value), electronic thermal relay function load factor, input power, output power, load meter, motor excitation current,
reference voltage output, motor load factor, power saving effect, PID set point, PID measured value, motor output, torque command, torque current
command, and torque monitor.
Output frequency, motor current (steady or peak value), output voltage, frequency setting, running speed, motor torque, overload, converter output
voltage (steady or peak value), electronic thermal relay function load factor, input power, output power, load meter, motor excitation current,
Operating cumulative energization time, actual operation time, motor load factor, cumulative power, energy saving effect, cumulative saving power, PID set
PU (FR- Status point, PID measured value, PID deviation, inverter I/O terminal monitor, input terminal option monitor (*2), output terminal option monitor (*2),
Indication
DU07 / option fitting status (*3), terminal assignment status (*3), torque command, torque current command, feed back pulse (*1),motor output
FR-PU07 /
FR-PU04) Fault Fault definition is displayed during the fault occurs, the output voltage/current/frequency/cumulative energization time right before the
Definition fault occurs and past 8 fault definitions are stored.
Interactive Operation guide/trouble shooting with a help function (*3)
Guidance
Overcurrent during acceleration, overcurrent during constant speed, overcurrent during deceleration, overvoltage during acceleration, overvoltage
during constant speed, overvoltage during deceleration, inverter protection thermal operation, motor protection thermal operation, heatsink overheat,
instantaneous power failure occurrence, undervoltage, input phase failure, motor overload, output side earth (ground) fault overcurrent, output
short circuit, main circuit element overheat, output phase failure, external thermal relay operation (*5), PTC thermistor operation (*5), option alarm,
parameter error, PU disconnection, retry count excess (*5), CPU alarm, operation panel power supply short circuit, 24VDC power output short
Protective / Warning Function circuit, output current detection value excess (*5), inrush current limit circuit alarm, communication alarm (inverter), opposite rotation deceleration
error*5, analog input error, fan fault, overcurrent stall prevention, overvoltage stall prevention, electronic thermal relay function prealarm, PU stop,
maintenance timer alarm (*2) (*5), parameter write error, copy operation error, operation panel lock, parameter copy alarm, speed limit indication,
signal loss detection (*1) (*5), speed deviation large (*1) (*5), overspeed (*1) (*5), excessive position error (*1) (*5), brake sequence error (*5),
encoder phase error (*1) (*5), regeneration converter overcurrent, regeneration converter circuit fault, regeneration converter transistor protection
thermal
Ambient Temperature -10°C to +50°C (non-freezing)
Environment
436
A701 Terminal Connection Diagram
Sink logic
Main circuit terminal P/+ N/-
Control circuit terminal *6 *6
MCCB MC
R/L1 Inrush current
Three-phase AC S/L2 limit circuit
power supply U Motor
T/L3
V
IM
R1/L11 W
Jumper
*1 S1/L21 Earth (Ground)
*1. To supply power to the
control circuit separately, Main circuit *6. Do not connect any options to P/+ and
remove the jumper across Earth N/-.
R1/L11 and S1/L21. (Ground) Control circuit
Control input signals (No voltage input allowed) C1 Relay output
Forward STF
Terminal functions vary with rotation
the input terminal B1 Terminal functions
start Relay output 1 vary with the output
assignment (Pr. 178 to Pr. 189) Reverse STR
rotation (Fault output) terminal assignment
A1
start STOP (Pr. 195, Pr. 196)
Start self-
holding selection C2
RH
High speed
B2
Multi-speed Middle RM Relay output 2
selection speed A2
RL
*2. JOG terminal can be used
Low speed
as pulse train input terminal. Open collector output
Use Pr. 291 to select JOG *2 RUN
JOG/pulse. Jog mode Running
Terminal functions
RT SU
Second function selection Up to frequency vary with the output
terminal assignment
*3. AU terminal can be MRS IPF Instantaneous (Pr. 190 to Pr. 194)
Output stop power failure
used as PTC input
terminal. RES *3 OL
Reset Overload
AU
Terminal 4 input selection AU FU
(Current input selection) Frequency detection
CS PTC
SOURCE
IB(NA)0600240
12 Bit Digital Input FR-A7AX S definitions
Digital Output Manuals available for download at www.meau.com
FR-A7AY S
Ext. Analog Output
BiPolar Analog Output Building Management Options
High Res Analog Input FR-A7AZ -
FR-A7N-ETH FR-A7N-XLT ETH-1000 XLTR-1000
Motor Thermistor Network Type / Model
(*2,*3,*4) (*2,*3,*4) (*5,*6) (*5,*6)
CC-Link FR-A7NC S BACnet/IP X - X -
EtherNet/IP X - X -
Communication
ControlNET (*1) FR-A7NCN S
Communication
Modbus TCP X - X -
Gateway
DeviceNet FR-A7ND S
PROFINET IO X - X -
EtherNet/IP (*1) FR-A7NE S BACnet MS/TP - X X X
LonWorks FR-A7NL S Metasys N2 - X X X
Profibus DP FR-A7NP S Siemens FLN - X - -
SSCNET III FR-A7NS S Stocked Item S S - -
Notes:
Note: 1. A701 series supports only the above listed plug-in options. 1. For additional information, visit www.iccdesigns.com
Those options not listed cannot be used with the A701 series. 2. Physically mounts within VFD and powered by VFD
3. Deep control cover is required
4. FR-E7TR option recommended. (PU connector not available for use)
5. Communication to multiple VFD’s is possible
6. Mounted and powered external to VFD
Software
Model Number Description Stocked Item
Programming and diagnostic software
FR-CONFIGURATOR S
(ver. 3.20 or greater)
438
V500 Series
Variable Frequency Drives True, Closed Loop Vector Control
This series achieves high precision and fast response that exceeds the performance of conventional
general-purpose inverters. They can be used in specialized applications such as line control and elevators.
By incorporating our original all-digital vector control, • 4-Quadrant torque control standard
high starting torque and high speed response have • Multiple parameters for tailoring to a wide variety
been made possible for both velocity and torque control of applications
modes.
• Simple positioning included as standard
• 2 to 75 Horsepower at 240V • DC Link Reactor standard (V500L)
• 2 to 75 Horsepower at 480V • Peripheral devices such as power regenerative
• 100% continuous torque at Zero speed converter (FR-CV, FR-RC, MT-RC) available
• Auto Tuning to other manufacturer’s constant torque • Communications options: DeviceNet, Profibus DP,
motor with encoder CC-Link, Modbus Plus, SSCNet
• Easy to use Parameter Unit
Rated Current (A) 9.0 13.0 20.0 28.5 37.5 54.0 72.8 88.0 103.5 126.5 166.0 198.0 264.0
Overload Current Rating (*1) 150% 60 sec., 200% 0.5 sec. (inverse time characteristics)
Output
Voltage (*2) 3-Phase 200-220V 50 Hz, 200-240V 60 Hz 3-Phase 200-220V 50 Hz, 200-230V 60 Hz
440
V500 General Specifications
Control Specifications
Control System Soft- PWM control or high carrier frequency sine-wave PWM control can be selected. Vector control or V/F control can be selected.
Control Mode Speed control, torque control, position control
Analog
0.03% of maximum set speed
Frequency Control Input
Resolution Digital
0.003% against maximum settings (0.1 rpm units for minimum setting)
Input
Acceleration / Deceleration Time 0 to 3600 sec (0.1 second increments)
Acceleration / Deceleration
Linear, S pattern (3 types) or backlash compensation acceleration/deceleration can be selected
Pattern
Torque Restriction Level Torque restriction value can be set (0 to 400% variable)
Input Signal
Terminal No. Setting Range Speed Control Torque Control
0 to 10V
2 Main speed setting Speed restriction
(resolution 0.03%)
Analog Setting Signal Auxiliary speed setting, magnetic
0 to ±10V Speed restriction compensation, magnetic flux command,
1 flux command regenerative torque
(resolution 0.05%) driving side speed restriction
restriction
0 to ±10V
3 Torque restriction (Torque bias) Torque command
(resolution 0.05%)
Main speed setting (in this case,
0 to ±10V Speed restriction (at this time, terminal 2 is invalid)
With Option FR-V5AX 6 terminals 1 and 2 are invalid)
(resolution 0.003%) Torque command (at this time, terminal 3 is valid)
Torque restriction
Environment
3 fixed function
Forward rotation command, alarm reset, external thermal relay
terminals
Contact Signal
5 multi-function Selection can be made from reverse rotation command, multi-speed setting (max. 15 speeds), remote setting, jog operation,
terminals second function selection, third function selection, output stop, three-wire control, pre-excitation, control mode switchover,
torque restriction selection, S pattern switchover, PID control terminal, orientation command, brake opening completion
6 multi-function signal, PU operation/external operation switchover, torque bias selection 1, torque bias selection 2, P control selection, servo
With Option (FR-V5AX)
terminals on, HC connection, PU/external interlock, external DC brake start, and commanded position selection
1 Form C Relay
Contact Signal (230VAC 0.3A,
30VDC 0.3A) Selection con be made from inverter running, up to speed, instantaneous power failure (undervoltage) speed detection,
3 multi-function second speed detection, third speed detection, PU operation mode, overload alarm, regenerative brake pre-alarm,
Open Collector Signal
terminals electronic thermal relay pre-alarm, output current detection, zero current detection, PID lower limit, PID upper limit,
3 multi-function PID forward /reverse output, operation ready, operation ready 2. brake opening request, fan fault output, fin overheat
With Option (FR-V5AY)
terminals pre-alarm, orientation in-position, forward rotation output, reverse rotation output, low speed output, torque detection,
1 multi-function regenerative status output, minor fault output, alarm output, maintenance timer output, remote output, speed detection,
With Option (FR-V5AM) in-position and trace status
terminal
7 multi-function
With Option (FR-A5AY)
terminals
0 to ±10V, 12 bits x
Analog Output 1CH 0 to 10V, 12 bits
x 1CH Selection can be made from speed, output current, output voltage, preset speed, output frequency, motor torque, converter
output voltage, regenerative brake duty, electronic thermal relay load factor, output current peak value, converter output
0 to ±10V, 10 bits x voltage peak value, load meter, motor exciting current, motor output, reference voltage
With Option (FR-A5AY) 1CH 0 to 20mA, 10
bits x 1CH
Encoder Pulse Output Option
A phase, B phase, Z phase, (A and B phases can be divided) Open collector/differential line driver
(FR-V5AY)
Maximum/minimum speed setting, speed jump, external thermal relay input selection, polarity reversible operation, override function, automatic
restart operation after instantaneous power failure, forward/reverse operation prevention, operation mode selection, offline auto tuning function,
Operational Functions online auto tuning function, easy gain tuning, computer link operation, remote setting, brake sequence, second function, third function, multi-speed
operation, coasting to stop, power failure stop, PID control, speed feed forward, model adaptive speed control, master/slave, torque bias, 12-bit
digital command (FR-A5AX option), pulse train input (FR-A5AP option), motor thermistor interface (FR-V5AX option), and simple positioning
Ambient Temperature -10°C to +50°C (Non-freezing) / 14°F to 122°F
Ambient Humidity 90% RH or less (Noncondensing)
Storage Temperature (*1) -20°C to +65°C / -4°F to 149°F
Atmosphere For indoor use; no corrosive gasses, flammable gasses, oil mist, dust or dirt present
Attitude 1000m above sea level. Contact factory for higher altitude deratings.
Vibration 5.9 m/s² (0.6G max.) based on JIS C 0911
Display
Selection can be made from speed, output current, output voltage, preset speed, output frequency, motor torque, converter output voltage,
Parameter Unit (FR-DU04-1/ regenerative brake duty, electronic thermal relay load factor, output current peak value, converter output voltage, peak value, input terminal
FR-PU04V) status (PU04V), load meter, motor exciting current, position pulse, cumulative energization time, actual operation time, motor load factor, torque
command, torque current command, feedback pulse, motor output, trace status
Alarm definition is displayed when protective function is activated. 8 past alarm definitions are stored.
Alarm Definition
(Only 4 alarm definitions are stored in the DU04-1)
Overcurrent shut-off (acceleration, deceleration, constant speed), regenerative overvoltage shut-off (acceleration, deceleration, constant speed),
undervoltage, instantaneous power failure, overload shut-off (electronic thermal relay), brake transistor alarm, earth (ground) fault current, power
Protective Functions output short circuit, stall prevention, external thermal relay, fin overheat, fan fault, option alarm, parameter error, PU disconnection, encoder
no-signal, large speed deviation, overspeed large position error, CPU error, encoder phase error, output phase loss excessive retries,
brake sequence error
Note:
1. Temperature that can be applied for short times, such as in transit.
Notes:
1. Terminal PR is provided on the 15kW and smaller capacities, and terminal PX is provided on the 5.5kW and smaller capacities.
2. When using FR-ABR with the 5.5kW or smaller capacity, remove this jumper.
3. Remove this jumper when using FR-BEL for 55kW and smaller capacities. DC link reactor included with 75kW and larger.
4. The converter’s life will be shortened by repeated in-rush currents when the power is turned ON, so do not turn the power ON and OFF frequently.
5. Prepare a ± 10V external power supply for terminals 1 and 3.
6. When using a motor without a thermal protector, set Pr.876 “Thermal protector input” to 0 and set Pr.9 (Pr.452) “Electronic thermal (2nd electronic thermal).
7. The terminal functions can be changed with the input terminal function selection (Pr.180 to Pr.183, Pr.187)
8. The terminal functions can be changed with the output terminal function selection (Pr.190 to Pr.192, Pr.195)
9. Change the connector according to the encoder power supply specifications.
10. The sink logic and source logic will change when the connector is changed.
11. Use of the 2W1kW is recommended when the settings are changed frequently.
12. Always ground the inverter and motor.
442
Engineered Solutions
Manufactured to the highest standards in UL approved facilities, The Engineered Solutions program takes Mitsubishi’s high performance control
products and engineers them into ready-to-use form.
Custom Engineered Solutions offer the performance and reliability of Mitsubishi products in
packages tailored to your exact specification.
Part Number Structure - Sized up to 40HP (208-240V) and 75HP (380 - 480V)
F1
4V 380 - 480V B Manual 3 contactor bypass S5 Drive trip/run relay (non-bypass only)
444
FR-F700 Based VFD Complete Bypass System - NEMA 1
Standard Product with
Circuit Breaker & 3 Contactor 208V Based VFD System Panel 460V Based VFD System Panel
Bypass VFD System Size Size
HP KW Model Number Stk. Item Amps Model Number Stk. Item Amps
1 0.75 F1C2V001BD - 4.2 N1A F1C4V001BD - 2.1 N1A
2 1.5 F1C2V002BD S 7 N1A F1C4V002BD S 3.5 N1A
3 2.2 F1C2V003BD S 9.6 N1A F1C4V003BD S 4.8 N1A
5 3.7 F1C2V005BD S 15.2 N1A F1C4V005BD S 7.6 N1A
7.5 5.5 F1C2V007BD S 23 N1B F1C4V007BD S 11.5 N1A
10 7.5 F1C2V010BD S 31 N1B F1C4V010BD S 16 N1A
15 11 F1C2V015BD S 45 N1B F1C4V015BD S 23 N1B
20 15 F1C2V020BD S 58 N1B F1C4V020BD S 29 N1B
25 18.5 F1C2V025BD S 70 N1C F1C4V025BD S 35 N1C
30 22 F1C2V030BD S 85 N1C F1C4V030BD S 43 N1C
40 30 F1C2V040BD S 114 N1D F1C4V040BD S 57 N1C
50 - - - - - F1C4V050BD S 70 N1D
60 - - - - - F1C4V060BD S 85 N1D
75 - - - - - F1C4V075BD S 106 N1D
HP KW Model Number Stk. Item Amps Model Number Stk. Item Amps
1 1 F3C2V001BD - 4.2 N3A F3C4V001BD - 2.1 N3A
2 1.5 F3C2V002BD - 7 N3A F3C4V002BD - 3.5 N3A
3 2.2 F3C2V003BD - 9.6 N3A F3C4V003BD - 4.8 N3A
5 3.7 F3C2V005BD - 15.2 N3A F3C4V005BD - 7.6 N3A
7.5 5.5 F3C2V007BD - 23 N3A F3C4V007BD - 11.5 N3A
10 7.5 F3C2V010BD - 31 N3B F3C4V010BD - 16 N3B
15 11 F3C2V015BD - 45 N3C F3C4V015BD - 23 N3B
20 15 F3C2V020BD - 58 N3C F3C4V020BD - 29 N3C
25 18.5 F3C2V025BD - 70 N3D F3C4V025BD - 35 N3C
30 22 F3C2V030BD - 85 N3D F3C4V030BD - 43 N3C
40 30 F3C2V040BD - 114 N3D F3C4V040BD - 57 N3C
50 37 F3C2V050BD - 140 N3E F3C4V050BD - 70 N3D
60 45 - - - - F3C4V060BD - 85 N3D
75 55 - - - - F3C4V075BD - 106 N3E
100 75 - - - - F3C4V100BD - 144 N3E
125 90 - - - - F3C4V125BD - 180 N3E
446
C1-D Enclosed Drives for Commercial Pump and Fan Control – NEMA 1
C 1 -D F V
To Motor
448
F8 Type 18 Pulse Controllers
F8 controllers are intended for the control of pumps and fans. 18 pulse technology is used to ensure that the quality of the site power supply
is maintained. These 460VAC Drives (10-800 HP) are LD rated at 120% overload for one minute, available in both bypass and non-bypass
configurations in NEMA 12 Ventilated Floor mounted cabinets. UL508A rated to meet IEEE519-1992 standards.
Base System Includes:
• NEMA 12 ventilated construction • RS-485, Modbus RTU Communication standard, EMI / RFI
• Standard Hoffman ANSI 61 gray paint filter standard
• 18 Pulse Clean Power Design Technology • AutoCAD documentation packet
• 3 contactor bypass with TEST mode • Instruction manuals for VFD and controller
• Choice of bypass or non-bypass units • UL / cUL 508A
• Catch a spinning load / windmill start activated • Hardware options: Damper vane actuator relay, extended analog
output, hand-off autoswitch with potentiometer, PU07 keypad /
• Adjustable overload relay, class 20 equivalent display door mounted
• Programming / display keypad and speed setting dial • Communications Options: BACnet® MS/TP, Metasys® N2,
• Choice of fused disconnect or circuit breaker (standard) LonWorks®, Siemens® FLN(P1), EtherNet/IP™, BACnet® IP,
• Control transformer, fused primary and secondary Modbus® TCP/IP, PROFINET
• Terminal blocks for control connections • 2 year warranty
F8 4V
450
For A700 and F700 VFD – NEMA 12 or NEMA 3R Construction
Base System Includes: G
• RAL 7035 light gray paint
• Bottom mounted inlet and exhaust vents
• F700 controller with LCD keypad / display
• LD Rated 120% overload for one minute Symbol Input/Output Voltage Symbol Choke/Reactor Type Symbol Options
2V 3/60/208 (230/240)VAC D DC Link Choke
• DC Link Choke included as standard 4V 3/60/460 (480)VAC 3 3% Input Reactor (option)
S4 Alphanumeric keypad
• Choice of fused disconnect or UL 489 circuit 5 5% Input Reactor (option) Symbol Network Type
452
Line / Load Reactor Electrical Data
Model Number Watts Loss Wire Range (AWG) Terminal Torque (in / lbs) Ind. mH Fund Amps Max Amps
MRL-00201 8 22 14 4.5 12 2 3
MRL-00202 12 22 14 4.5 20 2 3
MRL-00203 16 22 14 4.5 32 2 3
MRL-00204 11 22 14 4.5 6 2 3
MRL-00401 15 22 14 4.5 3 4 6
MRL-00402 20 22 14 4.5 6.5 4 6
MRL-00403 20 22 14 4.5 9 4 6
MRL-00404 21 22 14 4.5 12 4 6
MRL-00801 20 22 14 4.5 1.5 8 12
MRL-00802 29 22 14 4.5 3 8 12
MRL-00803 26 22 14 4.5 5 8 12
MRL-00804 28 22 14 4.5 7.5 8 12
MRL-01201 26 22 5 16 1.25 12 18
MRL-01202 31 22 5 16 2.5 12 18
MRL-01203 41 22 5 16 4.2 12 18
MRL-01801 36 22 5 16 0.8 18 27
MRL-01802 43 22 5 16 1.5 18 27
MRL-01803 43 22 5 16 2.5 18 27
MRL-02501 48 22 5 16 0.5 25 37.5
MRL-02502 52 22 5 16 1.2 25 37.5
MRL-02503 61 22 5 16 1.8 25 37.5
MRL-03501 49 22 5 16 0.4 35 52.5
MRL-03502 54 22 5 16 0.8 35 52.5
MRL-03503 54 18 4 20 1.2 35 52.5
MRL-04501 54 18 4 20 0.3 45 67.5
MRL-04502 62 18 4 20 0.7 45 67.5
MRL-04503 65 18 4 20 1.2 45 67.5
MRL-05501 64 6 0 6-4(45) & 2-0(50) 0.25 55 82.5
MRL-05502 67 6 0 6-4(45) & 2-0(50) 0.5 55 82.5
MRL-05503 71 6 0 6-4(45) & 2-0(50) 0.85 55 82.5
MRL-08001 82 6 0 6-4(45) & 2-0(50) 0.2 80 120
MRL-08002 86 6 0 6-4(45) & 2-0(50) 0.4 80 120
MRL-08003 96 6 0 6-4(45) & 2-0(50) 0.7 80 120
MRL-10001 94 6 0 6-4(45) & 2-0(50) 0.15 100 150
MRL-10002 84 6 0 6-4(45) & 2-0(50) 0.3 100 150
MRL-10003 108 6 0 6-4(45) & 2-0(50) 0.45 100 150
MRL-13001 108 2 0000 150 0.1 130 195
MRL-13002 180 2 0000 150 0.2 130 195
MRL-13003 128 2 0000 150 0.3 130 195
MRL-16001 116 2 0000 150 0.075 160 240
MRL-16002 149 2 0000 150 0.15 160 240
MRL-16003 138 2 0000 150 0.23 160 240
MRL-20001B14 124 Copper tab Not Applicable 0.055 200 300
MRL-20002B14 168 Copper tab Not Applicable 0.11 200 300
MRL-20003B14 146 Copper tab Not Applicable 0.185 200 300
MRL-25001B14 154 Copper tab Not Applicable 0.045 250 375
MRL-25002B14 231 Copper tab Not Applicable 0.09 250 375
MRL-25003B14 219 Copper tab Not Applicable 0.15 250 375
MRL-32001B14 224 Copper tab Not Applicable 0.04 320 480
MRL-32002B14 264 Copper tab Not Applicable 0.075 320 480
MRL-32003B14 351 Copper tab Not Applicable 0.125 320 480
MRL-40001B14 231 Copper tab Not Applicable 0.03 400 600
MRL-40002B14 333 Copper tab Not Applicable 0.06 400 600
MRL-40003B14 293 Copper tab Not Applicable 0.105 400 600
MRL-50001 266 Copper tab Not Applicable 0.025 500 750
MRL-50002 340 Copper tab Not Applicable 0.05 500 750
MRL-50003 422 Copper tab Not Applicable 0.085 500 750
MRL-60001 307 Copper tab Not Applicable 0.02 600 900
MRL-60002 414 Copper tab Not Applicable 0.04 600 900
MRL-60003 406 Copper tab Not Applicable 0.065 600 900
MRL-75001 427 Copper tab Not Applicable 0.015 750 1125
MRL-75002 630 Copper tab Not Applicable 0.029 750 1125
MRL-75003 552 Copper tab Not Applicable 0.048 750 1125
MRL-85001 798 Copper tab Not Applicable 0.015 850 1063
MRL-85002 930 Copper tab Not Applicable 0.027 850 1063
MRL-85003 1133 Copper tab Not Applicable 0.042 850 1063
MRL-90001 860 Copper tab Not Applicable 0.013 900 1125
MRL-90002 1020 Copper tab Not Applicable 0.025 900 1125
MRL-90003 1365 Copper tab Not Applicable 0.04 900 1125
MRL-100001 940 Copper tab Not Applicable 0.011 1000 1250
MRL-100002 1090 Copper tab Not Applicable 0.022 1000 1250
MRL-100003 1500 Copper tab Not Applicable 0.038 1000 1250
For additional information visit http://www.mtecorp.com/lineload.html
454
Micro MAX™ AC Inverter Duty Motor
1000:1 Constant Torque (TENV) • 20:1 Constant Torque (TEFC)
Designed for direct replacement of PMDC or any other variable speed application where up to a 1000:1 constant torque speed range
is required. Typical uses include: machine tools, conveyors, packaging machines, batching machines and printing equipment.
• Replaces 90 and 180 volt PMDC motors when used with • Continuous duty at 40°C ambient
AC variable frequency drives • “Quick Connect” terminal board as noted
• Constant torque operation from 0 to base speed (TENV ratings) • Top mounted conduit box with pigtail leads
• Constant torque operation from 1/20 speed to base speed (TEFC and 1.5Hp TENV)
(TEFC ratings) • UL recognized and CSA certified
• Constant horsepower to twice base speed (RPM) • Three year warranty
• Class H insulation with CR200 magnetic wire
C-Face Footless
Hp RPM Volts Encl. Frame Catalog No. F.L.A. Weight Notes
1/8 1800 230 TENV 56C Y606 * 1.0 17 N, Q
1/4 1800 230 TENV 56C Y501 * 1.0 17 N, Q
1/3 1800 230 TENV 56C Y503 * 1.2 17 N, Q
1800 230 TENV 56C Y505 * 1.8 19 N, Q
1/2 1800 230/460 TENV 56C Y374 * 1.8/0.9 19 N
1800 575 TENV 56C Y375 * 0.7 19 N, Q
1800 230 TEFC 56C Y507 * 2.8 23
3/4 1800 230/460 TEFC 56C Y376 * 2.8/1.4 23
1800 575 TEFC 56C Y377 1.1 23
1800 230 TEFC 56C Y521 * 3.2 27
1 1800 230/460 TEFC 56C Y378 * 3.2/1.6 27
1800 575 TEFC 56C Y379 * 1.3 27
General Notes:
* Marathon Motors stock item.
N: Totally Enclosed Non Ventilated; Q: “Quick Connect” terminal board; 6: Bolt-on, removable base for footless mounting option.
For additional information visit www.marathonelectric.com/motors/search.asp
456
Blue MAX™ 2000 Vector Duty
2000:1 Constant Torque
Designed for inverter or vector duty applications where up to a 2000:1 constant torque speed range is required. Typical uses
include: material handling, machine tools, conveyors, crane & hoist, metal processing, test stands, pumps, compressors, textile
processing and other industrial machinery installed in dusty or dirty environments where cast iron construction is required.
• Class H MAX GUARD insulation system • Ball bearing (roller bearing available 360 frame and larger)
• Constant torque operation from 0 to base speed on vector • Cast iron frame and brackets
drive, including TEFC (on V/Hz drives, TEFC motors are • Patented “fracket” design (TEBC enclosure)
limited to 20:1 Constant Torque)
• “B” temperature rise on Blower-Cooled motors
• Constant horsepower to twice base speed (143-254 frame);
1.5 times base (all others) • F1 standard, field reversible to F2
• Continuous duty at 40°C ambient • Encoder and brake provisions included on opposite drive end
• Optimized for operation with IGBT inverter (NEMA Design A) • UL recognized and CSA certified
• C-Face foot mount through 100 Hp as noted • Three year warranty
• Class F N/C thermostats
458