SECTION 1000

SECTION 1000
BRIDGES AND CULVERTS

1000. Materials for structures


1000.1 General - Materials to be used in the work shall conform to the specifications
mentioned on the drawings, the requirements laid down in this section and specifications for
relevant items of work covered under these specifications.

If any material, not covered in these specifications, is required to be used in the work, it shall
conform to relevant Indian Standards, if there are any, or to the requirements specified by
the engineer.

1000.2 Sources of material - The contractor shall notify the engineer of his proposed
sources of materials prior to delivery, if it is found after trial that sources of supply previously
approved do not produce uniform and satisfactory products, or if the product from any other
source proves unacceptable at any time, the contractor shall furnish acceptable material
from other sources at his own expense.

1000.3 SPECIFICATIONS FOR MATERIALS - BRICKS - Burnt clay bricks shall conform to
the requirements of IS : 1077, except that the minimum compressive strength when tested
flat shall not be less than 8.4 Mpa for individual bricks and 10.5 Mpa for average of 5
specimens. They shall be free from cracks and flaws and nodules of free time. The brick
shall have smooth rectangular faces with sharp corners and emit a clear ringing sound when
struck. The size may be according to local practice with a tolerance of +/- per cent.

1000.4 SPECIFICATIONS FOR MATERIALS - STONES - Stones shall be of the type


specified. It shall be hard, sound, free from cracks, decay and weathering and shall be
freshly quarried from an approved quarry. Stone with round surface shall not be used.

The stones, when immersed in water for 24 hours, shall not absorb water by more than 5 per
cent of their dry weight when tested in accordance with IS : 1124.

The length of stones shall not exceed 3 times its height nor shall they be less than twice its
height plus one joint. No stone shall be less in width than the height and width on the base
shall not be greater than three-fourth of the thickness of the wall nor less than 150 mm.

1000.5 SPECIFICATIONS FOR MATERIALS - CAST IRON - Cast iron shall conform to IS :
210. The grade number of the material shall not be less than 14.

1000. 6 SPECIFICATIONS FOR MATERIALS - CEMENT - Cement to be used in the works


shall be any of the following types with the prior approval of the engineer :
a) Ordinary Portland Cement, 33 Grade, conforming to IS : 269.
b) Rapid Hardening Portland Cement, conforming to IS : 8041.
c) Ordinary Portland Cement, 43 Grade, conforming to IS : 8112.
1000-1
SECTION 1000

d) Ordinary Portland Cement, 53 Grade, conforming to IS : 12269.


e) Sulphate Resistant Portland Cement, conforming to IS : 12330.

Cement conforming to IS : 269 shall be used only after ensuring that the minimum required
design strength can be achieved without exceeding the maximum permissible cement of 540
kg/cu. m. of concrete.

Cement conforming to IS : 8112 and IS : 12269 may be used provided the minimum cement
content mentioned elsewhere from durability considerations is not reduced. From strength
considerations, these cements shall be used with a certain caution as high early strengths of
cement in the 1 to 28 – day range can be achieved by finer grinding and higher constituent
ratio of C3S/C2S, where C3S is Tricalcium Silicate and C2S is Dicalcium Silicate. In such
cements, the further growth of strength beyond say 4 weeks may be much lower than that
traditionally expected. Therefore, further strength tests shall be carried out for 56 and 90
days to fine tune the mix design from strength considerations.

Cement conforming to IS : 12330 shall be used when sodium sulphate and magnesium
sulphate are present in large enough concentration to be aggressive to concrete. The
recommended threshold values as per IS : 456 are sulphate concentration in excess of 0.2
per cent in soil sub-strata or 300 ppm (0.03 per cent) in ground water. Tests to confirm
actual values of sulphate concentration are essential when the structure is located near the
sea coast, chemical factories, agricultural land using chemical fertilizers and sites where
there are effluent discharges or where soluble sulphate bearing ground water level is high.
Cement conforming to IS : 12330 shall be carefully selected from strength considerations to
ensure that the minimum required design strength can be achieved without exceeding the
maximum permissible cement content of 540 kg/cu. m. of concrete.

Cement conforming to IS : 8041 shall be used only for precast concrete products after
specific approval of the Engineer.

Total chloride content in cement shall in no case exceed 0.05 per cent by mass of cement.
Also, total sulphur content calculated as sulphuric anhydride (SO3) shall be in no case
exceed 2.5 per cent and 3.0 per cent when tri-calcium aluminate per cent by mass is up to 5
or greater than 5 respectively.

1000. 7. SPECIFICATIONS FOR MATERIALS - COARSE AGGREGATES - For plain and


reinforced cement concrete (PCC and RCC) or prestressed concrete (PSC) works, coarse
aggregate shall consist of clean, hard, strong, dense, non-porous and durable pieces of
crushed stone, crushed gravel, natural gravel or a suitable combination thereof or other
approved inert material. They shall not consist pieces of disintegrated stones, soft, flaky,
elongated particles, salt, alkali, vegetable matter or other deleterious materials in such
quantities as to reduce the strength and durability of the concrete, or to attack the steel
reinforcement. Coarse aggregate having positive alkali-silica reaction shall not be used. All

1000-2
SECTION 1000

coarse aggregates shall conform to IS : 383 and tests for conformity shall be carried out as
per IS : 2386, Parts 1 to 8

The contractor shall submit for the approval of the engineer, the entire information indicated
in Appendix A of IS : 383.

Maximum nominal size of coarse aggregate for various structural components in PCC, RCC
or PSC, shall conform to section 1700.

The maximum value for flakiness index for coarse aggregate shall not exceed 35 per cent.
The coarse aggregate shall satisfy the following requirements of grading :

Table 1000-1 Requirements of coarse aggregate


IS sieve size Per cent by Weight Passing the Sieve
40 mm 20 mm 12.5 mm
63 mm 100 --- ---
40 mm 95 – 100 100 ---
20 mm 30 – 70 95 – 100 100
12.5 mm --- --- 90 – 100
10 mm 10 – 35 25 – 55 40 – 85
4.75 mm 0–5 0 – 10 0 – 10

1000.8 SPECIFICATIONS FOR MATERIALS - SAND / FINE AGGREGATES - For masonry


work, sand shall conform to the requirements of IS : 2116.

For plain and reinforced cement concrete (PCC and RCC) or pre stressed concrete (PSC)
works, fine aggregates shall consist of clean, hard, strong and durable pieces of crushed
stone, crushed gravel, or a suitable combination of natural sand, crushed stone or gravel.
They shall not contain dust, lumps, soft or flaky, materials, mica or other deleterious
materials in such quantities as to reduce the strength and durability of the concrete, or to
attack the embedded steel. Motorised sand washing machines should be used to remove
impurities from sand. Fine aggregate having positive alkali-silica reaction shall not be used.

All fine aggregates shall conform to IS : 383 and tests for conformity shall be carried out as
per IS : 2386, (Parts I to VIII). The contractor shall submit to the engineer the entire
information indicated in Appendix A of IS : 383. The fineness modules of fine aggregate
shall neither be less than 2.0 nor greater than 3.5.

Sand/fine aggregate for structural concrete shall conform to the following grading
requirements

Table 1000 – 2
IS Sieve size Per cent by Weight Passing the Sieve
1000-3
SECTION 1000

Zone 1 Zone II Zone III


10 mm 100 100 100
4.75 mm 90 – 100 90– 100 90 – 100
2.36 mm 60 – 95 75 – 100 85 – 100
1.18 mm 30 – 70 55 – 90 75 – 100
600 micron 15 – 34 35 – 59 60 – 79
300 micron 5 – 20 8 – 30 12 – 40
150 micron 0 – 10 0 – 10 0 – 10

1000.9 SPECIFICATIONS FOR MATERIALS - STEEL


1000.9.1. Cast steel : The use of cast steel shall be limited to bearings and other similar
parts. Steel for castings shall conform to Grade 280 – 520 N of IS : 1030. In case where
subsequent welding is unavoidable in the relevant cast steel components, the letter N at the
end of the grade designation of the steel casting shall be replaced by letter W. 0.3 per cent
to 0.5 per cent copper may be added to increase the corrosion resistance properties.

1000.9.2. Steel for pre-stressing - The pre-stressing steel shall conform to either of the
following :
a) Plain hard drawn steel wire conforming to IS : 1785 (Part 1) and IS : 1785 (Part II).
b) Cold drawn indented wire conforming to IS : 6003.
c) High tensile steel bar conforming to IS : 2090.
d) Uncoated stress relieved strands conforming to IS : 6006.

1000.9.3. Reinforcement / untensioned steel - For plain and reinforced cement concrete
(PCC and RCC ) or prestressed concrete (PSC) works, the reinforcement / intentioned steel
as the case may be shall consist of the following grades of reinforcing bars.

Table 1000 – 3
Grade Bar type conforming to governing IS Characteristic Elastic modulus
designation specification strength Mpa GPa
S 240 IS : 432 Part IMild Steel Bar 240 200
S 415 IS : 1786 High Yield Strength Deformed 415 200
Bars (HYSD)

Other grades of bars conforming to IS : 432 and IS : 1786 shall not be permitted.

All steel shall be procured from original producers, no re-rolled steel shall be incorporated in
the work.

Only new steel shall be delivered to the site. Every bar shall be inspected before
assembling on the work and defective, brittle or burnt but shall be discarded. Cracked ends
of bars shall be discarded.

Fusion – bonded epoxy coated reinforcing bars shall meet the requirements of IS : 13620.
Additional requirements for the use of such reinforcement bars have been given below

1000-4
SECTION 1000

a) Patch up materials shall be procured in sealed containers with certificates from the
agency who has supplied the fusion bonded epoxy bars.

b) PVC coated G. I. binding wires of 18G shall only be used in conjunction with fusion
bonded epoxy bars.

c) Chairs for supporting the reinforcement shall also be of fusion bonded epoxy coated bars.

d) The cut ends and damaged portions shall be touched up with repair patch up material.

e) The bars shall be cut by saw-cutting rather than flame cutting.

f) While bending the bars, the pins of work benches shall be provided with PVC or plastic
sleeves.

g) The coated steel shall not be directly exposed to sun rays or rains and shall be protected
with opaque polyethelene sheets or such other approved materials.

h) While concreting, the workmen or trolleys shall not directly move on coated bars but can
move on wooden planks placed on the bars.

When specified in the contract, protective coating prescribed by CECRI shall be provided in
conformance to specifications given in Annexure 1000-A.1. The CECRI coating process
shall be allowed to be implemented at the site of works provided a representative of the
Institute is present throughout the duration of the coating process who shall certify that the
materials and workmanship are in accordance with prescribed specifications developed by
the Institute.

1000.9.4. Grey iron castings - Grey Iron castings to be used for bearings shall have the
following minimum properties :
(i) Minimum ultimate tensile strength 370 Mpa
(ii) Modulus of Elasticity 147000 Mpa
(iii) Brinell Hardness 230 Mpa
(iv) Shear Strength 370 Mpa
(v) Compressive Strength 1370 Mpa

The testing shall be as specified in IS : 210.

1000.9.5. Steel forgings - Forged steel pins shall comply with clause 3, 3A or 4 of IS : 1875
and steel forgings shall comply with clause 3, 3A, or 4 of IS : 2004. Raw materials of the
forging will be taken as per IS : 1875 with minimum reduction ratio of 1 : 8 : 1. Alternatively, if
forging is made from ingot, a minimum reduction ratio between the ingot and forging will be 4
: 1. Forging shall be normalised.
1000-5
SECTION 1000

1000.9.6. Structural Steel - Unless otherwise permitted herein, all structural steel shall
before fabrication comply with the requirements of the following Indian Standards :

IS : 226 : Structural Steel (Standard Quality)


IS : 961 : Structural Steel (High Tensile)
IS : 2062 : Weldable Structural Steel
IS : 8500 : Weldable Structural Steel (medium & high strength qualities)
IS : 1148 : Hot rolled rivet bars (up to 40 mm dia) for structural purposes
IS : 1149 : High tensile rivet bars for structural purposes
IS : 1161 : Steel tubes for structural purposes
IS : 4923 : Hollow Steel sections for structural use
IS : 11587 : Structural weather resistant steel
IS : 808 : Specifications for Rolled Steel Beam, Channel and Angle Sections
IS : 1239 : Mild Steel Tubes
IS : 1730 : Dimension for Steel plate, sheet and strip for structural and
general engineering purposes
IS : 1731 : Dimension for Steel flats for structural and general engineering
purposes
IS : 1732 : Dimension for round and square steel bars for structural and
general engineering purposes
IS : 1852 : Rolling and cutting tolerances for hot rolled steel products.

The use of structural steel not covered by the above standards may be permitted with the
specific approval of the authority. Refer to section 1900 for further details.

1000.9.7. Stainless steel - Stainless steel shall be austenitic chromium-nickel steel,


possessing rust, acid and heat resistant properties conforming to IS : 6603 and IS : 6911.
Mechanical properties /grade for such stainless steel shall be as specified by the accepting
authority, but in no case be inferior to mild steel. Generally, stainless steel is available as
per AISI grades. AISI 304 which is equivalent to grade 04Cr18Ni110 of IS : 6911 satisfies
the requirements of mechanical properties of structural steel. Other grades of stainless steel
for specific purposes may be provided as per specific requirements. For application in
adverse / corrosive environment, stainless steel shall conform to AISI 316L or 02G17 Ni Mo2
of IS : 6911.

1000.10 SPECIFICATIONS FOR MATERIALS - WATER - Water used for mixing and curing
shall be clean and free from injurious amounts of oils, acids, alkalis, salts, sugar, organic
materials or other substances that may be deleterious to concrete to concrete or steel.
Potable water is generally considered satisfactory for mixing concrete. Mixing and curing
with sea water shall not be permitted. As a guide, the following concentrations represent the
maximum permissible values :

a) To neutralise 200 ml sample of water, using phenolpthalein as an indicator, it should not


require more than 2 ml of 0.1 normal NaOH.
1000-6
SECTION 1000

b) To neutralise 200 ml sample of water, using methyl orange as in indicator, it should not
require more than 10 ml or 0.1 normal HCI.

c) The permissible limits for solids shall be as follows when tested in accordance with IS :
3025

Permissible Limits (max)


Organic 200 mg/lit
Inorganic 3000 mg/lit
Sulphates (SO4) 500 mg/lit
Chlorides (CI) 500 mg/lit *
Suspended matter 2000 mg/lit

* In case of structures of lengths 30 m and below, the permissible limit of chlorides


may be increased up to 1000 mg/lit.

All samples of water (including potable water) shall be tested and suitable measures taken
where necessary to ensure conformity of the water to the requirements stated herein.

a) The pH value shall not be less than 6.

1000.11. SPECIFICATIONS FOR MATERIALS – TIMBER - The timber used for structural
purposes shall conform to IS : 883.

1000.12. SPECIFICATIONS FOR MATERIALS - CONCRETE ADMIXTURES


1000.12.1. General - Admixtures are materials added to the concrete before or during
mixing with a view to modify one or more of the properties of concrete in the plastic or
hardened state.

Concrete admixtures are proprietary items of manufacture and shall be obtained only from
established manufacturers with proven track record, quality assurance and full fledged
laboratory facilities for the manufacture and testing of concrete.

The contractor shall provide the following information concerning each admixture after
obtaining the same from the manufacturer :

a) Normal dosage and detrimental effects, if any, of under dosage and over dosage.

b) The chemical names of the main ingredients in the admixtures.

c) The chloride content, if any, expressed as a percentage by the weight of the admixture.

d) Values of dry material content, ash content and relative density of the admixture which
can be used for Uniformity Tests.
1000-7
SECTION 1000

e) Whether or not the admixture leads to the entertainment of air when used as per the
manufacturer’s recommended dosage, and if so to what extent.

f) Where two or more admixtures are proposed to be used in any one mix, confirmation as
to their compatibility.

g) There would be no increase in risk of corrosion of the reinforcement or other embedments


as a result of using the admixture.

1000.12.2. Physical and chemical requirements - Admixtures shall conform to the


requirements of IS : 9103. In addition, the following conditions shall be satisfied :

a) “Plasticisers” and “Super – Plasticisers” shall meet the requirements indicated for “Water
reducing Admixtures”.

b) Except where resistance to freezing and thawing and to disruptive action of deicing salts
is necessary, the air content of freshly mixed concrete in accordance with the pressure
method given in IS : 1199 shall not be more than 2 per cent higher than that of the
corresponding control mix and in any case not more than 3 per cent of the test mix.

c) The chloride content of the admixture shall not exceed 0.2 per cent when tested in
accordance with IS : 6925. In addition, the maximum permissible limit of chloride content of
all the constituents as indicated in Section 1700 shall also be observed.

d) Uniformity tests on the admixtures are essential to compare qualitatively the composition
of different samples taken from batch to batch or from the same batch at different times.

The tests that shall be performed along with permissible variations in the same are indicated
below

- Dry Material Content : to be within 3 per cent and 5 per cent or liquid and solid
admixtures respectively of the value stated by the manufacturer.
- Ash content : to be within 1 per cent of the value stated by the manufacturer.

Relative Density (for liquid admixture) : to be within 2 per cent of the value stated by the
manufacturer.

e) All tests relating to the concrete admixtures shall be conducted periodically at an


independent laboratory and compared with the data given by the manufacturer.

1000.13. SPECIFICATIONS FOR REINFORCED CONCRETE PIPES - Reinforced concrete


pipes for highway structures shall be of NP4 type conforming to the requirements of IS : 458.

1000-8
SECTION 1000

1000.14. SPECIFICATIONS FOR MATERIALS - STORAGE


1000.14.1. General - All materials may be stored at proper places so as to prevent their
deterioration or intrusion by foreign matter and to ensure their satisfactory quality and fitness
for the work. The storage space must also permit easy inspection, removal and restorage of
the materials. All such materials even though stored in approved godowns/places, must be
subjected to acceptance test prior to their immediate use.

1000.14.2. Brick - Bricks shall not be dumped at site. They shall be stacked in regular tiers
as they are unloaded, to minimise breakage and defacement. The supply of bricks shall be
available at site at any time. Bricks selected for use in different situations shall be stacked
separately.

1000.14.3. Aggregates - Aggregate stockpiles may be made on ground that is denuded of


vegetation, is hard and well drained. If necessary, the ground shall be covered with 50 mm
plank.

Coarse aggregates, unless otherwise agreed by the engineer in writing, shall be delivered to
the site in separate sizes (2 sizes when nominal size is 25 mm or less and 3 sizes when the
nominal size is 32 mm or more). Aggregates placed directly on the ground shall not be
removed from the stockpile within 30 cm of the ground until the final cleaning up of the work,
and then only the clean aggregate will be permitted to be used.

In the case of fine aggregates, these shall be deposited at the mixing site not less than 8
hours before use and shall have been tested and approved by the engineer.

1000.14.4. Cement - Cement shall be transported, handled and stored on the site in such a
manner as to avoid deterioration or contamination. Cement shall be stored above ground
level in perfectly dry and water-tight sheds and shall be stacked not more than eight bags
high. Wherever bulk storage containers are used their capacity should be sufficient to cater
to the requirement at site and should be cleaned at least every 3 to 4 months.

Each consignment shall be stored separately so that it may be readily identified and
inspected and cement shall be used in the sequence in which it is delivered at site. Any
consignment or part of a consignment of cement which had deteriorated in any way, during
storage, shall not be used in the works and shall be removed from the site by the contractor
without charge to the employer.

The contractor shall prepare and maintain proper records on site in respect of delivery,
handling, storage and use of cement and these records shall be available for inspection by
the engineer at all times.

1000-9
SECTION 1000

The contractor shall make a monthly return to the engineer on the date corresponding to the
interim certificate date, showing the quantities of cement received and issued during the
month and in stock at the end of the month.

1000.14.5. Reinforcement / untensioned steel - The reinforcement bars, when delivered


on the job, shall be stored above the surface of the ground upon platforms, skids, or other
supports, and shall be protected from mechanical injury and from deterioration by exposure.

1000.14.6. Pre-stressing materials - All pre stressing steel, sheathing, anchorages and
sleeves or coupling must be protecting during transportation, handling and storage. The
prestressing steel, sheathing and other accessories must be stored under cover from rain or
damp ground and protected from the ambient atmosphere if it is likely to be aggressive.
Storage at site must be kept to the absolute minimum.

a) Tendon : Wire, strand and bar from which tendons are to be fabricated shall be stored
about 300 mm above the ground in a suitably covered and closed space so as to avoid
direct climatic influences and to protect them from splashes from any other materials and
from the cutting operation of an oxy-acetylene torch or arc welding process in the vicinity.
Under no circumstances, tendon material shall be subjected to any welding operation or on
site heat treatment or metallic coating such as galvanising. Storage facilities and the
procedures for transporting material into or out of store, shall be such that the material does
not become kinked or notched. Wire or strand shall be stored in large diameter coils which
enable the tendons to be laid out straight. As a guide, for wires above 5 mm dia, coils of
about 2 m dia without breaks or joints shall be obtained from manufacturer and stored.
Protective wrapping for tendons shall be chemically neutral. All prestressing steel must be
provided with temporary protection during storage.

b) Anchorage Components : The handling and strong procedures shall maintain the
anchorage components in a condition in which they can subsequently perform their function
to an adequate degree. Components shall be handled and stored so that mechanical
damage and detrimental corrosion are prevented. The corrosion of the gripping and
securing system shall be prevented. The use of correctly formulated oils and greases or of
other corrosion preventing material is recommended where prolonged storage is required.
Such protective material shall be guaranteed by the producer to be non-aggressive and non-
degrading.

Prestressing steel shall be stored in a closed store having single door with double locking
arrangements and no windows. Also the air inside the store shall be kept dry as far as
possible by using various means to the satisfaction of the engineer. Also instrument
measuring the air humidity shall be installed inside the store. This is with a view to
eliminating the possibility of initial rusting of prestressing steel during storage. The
prestressing steel shall be coated with water solvable grease. The prestressing steel should
be absolutely clean and without any signs of rust.

1000-10
SECTION 1000

All prestressing steel shall be stored at least 30 cm above ground level and it shall be
invariably wrapped by protective cover of tar paper or polythene or any other approved
material.

The contractor should see that prestressing steel shall be used within 3 months of its
manufacture. He should chalk out his programme in this respect precisely, so as to avoid
initial corrosion before placing in position.

1000.14.7. Water - Water shall be stored in containers/tanks covered at top and cleaned at
regular intervals in order to prevent intrusion by foreign matter or growth of organic matter.
Water from shallow, muddy or marshy surface shall not be permitted. The intake pipe shall
be enclosed to exclude silt, mud, grass and other solid materials and there shall be a
minimum depth of 0.60 m of water below the intake at all times.

1000.15 SPECIFICATIONS FOR MATERIALS TESTS AND STANDARD OF


ACCEPTANCE - All materials, even though stored in an approved manner shall be
subjected to an acceptance test prior to their immediate use.

Independent testing of cement for every consignment shall be done by the contractor at site
in the laboratory approved by the engineer before use. Any cement with lower quality than
those shown in manufacturer’s certificate shall be debarred from use. In case of imported
cement, the same series of tests shall be carried out before acceptance.

1000.15.1 Testing and approval of material :The contractor shall furnish test certificates
from the manufacturer/supplier of materials along with each batch of material(s) delivered to
site.

The contractor shall set up a field laboratory with necessary equipment, for testing of all
materials, finished products used in the construction as per requirements of conditions of
contract and the relevant specifications. The testing of all the materials shall be carried out
by the engineer or his representative for which the contractor shall make all the necessary
arrangements and bear the entire cost.

Tests which cannot be carried out i8n the field laboratory have to be got done at the
contractor’s cost at any recognised laboratory / testing establishments approved by the
engineer.

1000.15.2. Sampling of materials - Samples provided to the engineer or his representative


for their retention are to be labelled boxes suitable for storage.

Samples required for approval and testing must be supplied well in advance by at least 48
hours or minimum period required for carrying our relevant tests to allow for testing and
approval. Delay to works arising from the late submission of samples will not be acceptable
as a reason for delay in the completion of the works.
1000-11
SECTION 1000

If materials are brought from abroad, the cost of sampling/testing whether in India or abroad
shall be borne by the Contractor.

1000.15.3. Rejection of materials not conforming to the specifications - Any stack or


batch of material (s) of which sample (s) does not conform to the prescribed tests and quality
shall be rejected by the engineer or his representative and such materials shall be removed
from site by the contractor at his own cost. Such rejected materials shall not be made
acceptable by any modifications.

1000.15.4. Testing and approval of plant and equipment - All plants and equipment used
for preparing, testing and production of materials for incorporation into the permanent works
shall be in accordance with manufacturer’s specifications and shall be got approved by the
engineer before use.

1000-12