HFW-50 T5: Industrial Range Open Skid
HFW-50 T5: Industrial Range Open Skid
HFW-50 T5: Industrial Range Open Skid
INDUSTRIAL RANGE
Powered by FPT_IVECO
POWER kVA 50 55
POWER kW 40 44
HIMOINSA HEADQUARTERS:
Fábrica: Ctra. Murcia - San Javier, Km. 23,6 | 30730 SAN JAVIER (Murcia) Spain Himoinsa has the right to modify any feature without prior notice.
Tel.+34 968 19 11 28 Fax +34 968 19 12 17 Fax +34 968 19 04 20 |
info@himoinsa.com | www.himoinsa.com Weights and dimensions based on standard products. Illustrations may
include optional equipment.
Manufacture facilities:
SPAIN • FRANCE • INDIA • CHINA • USA • BRAZIL • ARGENTINA Technical data described in this catalogue correspond to the available
Subsidiaries: information at the moment of printing.
PORTUGAL | POLAND | GERMANY | UK | SINGAPORE | UAE | PANAMA |
DOMINICAN REPUBLIC | ARGENTINA | ANGOLA | SOUTH AFRICA The illustrations and images are indicative and may not coincide in their
entirety with the product.
Industrial design under patent.
2020-FEB.-12 01:29
Ctra. Murcia - San Javier, km. 23,6 | 30730 San Javier (Murcia) SPAIN | Tel.: +34 902 19 11 28 / +34 968 19 11 28
Fax: +34 968 19 12 17 | Export Fax +34 968 19 04 20 | E-mail:info@himoinsa.com | www.himoinsa.com
HFW-50 T5
Ctra. Murcia - San Javier, km. 23,6 | 30730 San Javier (Murcia) SPAIN | Tel.: +34 902 19 11 28 / +34 968 19 11 28
Fax: +34 968 19 12 17 | Export Fax +34 968 19 04 20 | E-mail:info@himoinsa.com | www.himoinsa.com
HFW-50 T5
APPLICATION DATA
EXHAUST SYSTEM NECESSARY AMOUNT OF AIR
Exhaust Gas Flow kg/s 0,069 Cooling Air Flow m³/s 1,6
Maximum allowed back pressure kPa 5 Alternator fan air flow m³/s 0,216
• Steel chassis • Chassis with integrated fuel tank • Fuel tank drain plug
• Emergency stop button • Fuel level gauge • Steel industrial silencer -15db(A)
attenuation
• Oil sump extraction kit • High mechanical strength
• Fuel transfer pump (Opcional).
• Anti-vibration shock absorbers • Epoxy polyester powder coating
• Steel residential silencer -35db(A)
attenuation. (Opcional).
2020-FEB.-12 01:29
Ctra. Murcia - San Javier, km. 23,6 | 30730 San Javier (Murcia) SPAIN | Tel.: +34 902 19 11 28 / +34 968 19 11 28
Fax: +34 968 19 12 17 | Export Fax +34 968 19 04 20 | E-mail:info@himoinsa.com | www.himoinsa.com
HFW-50 T5
FEATURES OF THE
CONTROL UNITS
CEM 7 CEA 7 CEC 7 CEM7 + CEC7
Voltage between phases • • • •
Voltage between neutral and phase • • • •
Current intensities • • • •
Generator Readings
Frequency • • • •
Apparent power (Kva) • • • •
Active power (Kw) • • • •
Reactive power (kVAr) • • • •
Power factor • • • •
Voltage between phases • • •
Voltage between phases and neutral • • •
Current intensities • • •
Frequency • • •
Mains Readings
Apparent power •
Active power •
Reactive power •
Power factor •
Coolant temperature • • •
Oil pressure • • •
Engine Readings
Ctra. Murcia - San Javier, km. 23,6 | 30730 San Javier (Murcia) SPAIN | Tel.: +34 902 19 11 28 / +34 968 19 11 28
Fax: +34 968 19 12 17 | Export Fax +34 968 19 04 20 | E-mail:info@himoinsa.com | www.himoinsa.com
HFW-50 T5
Short-circuit • • •
Asymmetry between phases • • • •
Incorrect phase sequence • • • •
Inverse power • • •
Overload • • •
Genset signal drop • • • •
Total hour counter • • • •
Partial hour counter • • • •
Kilowatt meter • • • •
Starts valid counters • • • •
Counters
GSM/GPRS modem ⓪ ⓪ ⓪ ⓪
Remote screen ⓪ ⓪ ⓪
Tele signal ⓪ (8 + 4) ⓪ (8 + 4) ⓪ (8 + 4)
J1939 ⓪ ⓪ ⓪
Alarm history • • • •
(10) / (opc. +100) (10) / (opc. +100) (10) / (opc. +100) (10) / (opc. +100)
External start • • • •
Start inhibition • • • •
Mains failure start • • •
Start under normative EJP • • •
Pre-heating engine control • • •
Genset contactor activation • • • •
Mains & Genset contactor activation • • •
Fuel transfer control • • •
Engine temperature control • • •
Manual override • • •
Programmable alarms • • •
Genset start function in test mode • • • •
Features
Programmable outputs • • •
Multilingual • • • •
GPS Positioning ⓪ ⓪ ⓪
Synchronisation ⓪ ⓪ ⓪
Mains synchronization
Special Functions
⓪ ⓪ ⓪
Second Zero elimination ⓪ ⓪ ⓪
RAM7 ⓪ ⓪ ⓪
Remote screen ⓪ ⓪ ⓪
Programming timer ⓪ ⓪ ⓪
2020-FEB.-12 01:29
• Standard Optional
Ctra. Murcia - San Javier, km. 23,6 | 30730 San Javier (Murcia) SPAIN | Tel.: +34 902 19 11 28 / +34 968 19 11 28
Fax: +34 968 19 12 17 | Export Fax +34 968 19 04 20 | E-mail:info@himoinsa.com | www.himoinsa.com
HFW-50 T5
CONTROL
PANELS
M5 AS5
Digital manual Automatic panel
Auto-Start control WITHOUT transfer
panel and thermal switch and
magnetic protection WITHOUT mains
(depending on control with CEM7
current and voltage) unit. (*) AS5 as
and differential with optional with CEA7
CEM7. unit. Automatic panel
without transfer
Digital control unit switch and WITH
CEM7 mains control.
CC2 AS5 +
CC2
Himoinsa Switching
cabinet WITH display. Automatic panel
Digital control unit WITH transfer switch
CEC7 and with mains
control. The display
will be on the genset
and on the cabinet.
Digital control unit
CEM7+CEC7
AC5
Automatic mains
failure control panel.
Wall-mounted
cabinet WITH
transfer switch and
thermal magnetic
protection
(depending on
current and voltage).
Digital control unit
CEA7
Electrical system
• Electric control and power panel • Battery charger (standard on • Starter battery/ies installed
with measurements devices gensets with automatic control (cables and bracket included)
and control unit (according to panels)
necessity and configuration) • Ground connection electrical
• Heating resistor (standard on installation with connection
• 4-pole thermal magnetic circuit sets with automatic control ready for ground spike (not
breaker panels) supplied)
• Adjustable earth leakage • Battery charger alternator with • Battery Switch (Opcional).
protection (time & sensitivity) ground connection
standard in M5 and AS5, with
thermal magnetic protection
2020-FEB.-12 01:29
Ctra. Murcia - San Javier, km. 23,6 | 30730 San Javier (Murcia) SPAIN | Tel.: +34 902 19 11 28 / +34 968 19 11 28
Fax: +34 968 19 12 17 | Export Fax +34 968 19 04 20 | E-mail:info@himoinsa.com | www.himoinsa.com