HBW-200 T5: Industrial Range Standard Soundproofing
HBW-200 T5: Industrial Range Standard Soundproofing
HBW-200 T5: Industrial Range Standard Soundproofing
Powered by BAUDOUIN
G2 class load acceptance in accordance with ISO 8528-5:2013 Himoinsa has the right to modify any feature without prior notice.
HIMOINSA HEADQUARTERS: Weights and dimensions based on standard products. Illustrations may
Fábrica: Ctra. Murcia - San Javier, Km. 23,6 | 30730 SAN JAVIER (Murcia) Spain include optional equipment.
Tel.+34 968 19 11 28 Fax +34 968 19 12 17 Fax +34 968 19 04 20 |
info@himoinsa.com | www.himoinsa.com Technical data described in this catalogue correspond to the available
information at the moment of printing.
Manufacture facilities:
SPAIN • FRANCE • INDIA • CHINA • USA • BRAZIL • ARGENTINA The illustrations and images are indicative and may not coincide in their
Subsidiaries: entirety with the product.
PORTUGAL | POLAND | GERMANY | UK | SINGAPORE | UAE | PANAMA |
DOMINICAN REPUBLIC | ARGENTINA | ANGOLA | SOUTH AFRICA Industrial design under patent.
2020-MAY.-04 18:46
Ctra. Murcia - San Javier, km. 23,6 | 30730 San Javier (Murcia) SPAIN | Tel.: +34 902 19 11 28 / +34 968 19 11 28
Fax: +34 968 19 12 17 | Export Fax +34 968 19 04 20 | E-mail:info@himoinsa.com | www.himoinsa.com
HBW-200 T5
Ctra. Murcia - San Javier, km. 23,6 | 30730 San Javier (Murcia) SPAIN | Tel.: +34 902 19 11 28 / +34 968 19 11 28
Fax: +34 968 19 12 17 | Export Fax +34 968 19 04 20 | E-mail:info@himoinsa.com | www.himoinsa.com
HBW-200 T5
APPLICATION DATA
EXHAUST SYSTEM NECESSARY AMOUNT OF AIR
Exhaust Gas Flow m³/min 38,2 Cooling Air Flow m³/s 6,92
Maximum allowed back pressure mbar 60 Alternator fan air flow m³/s 0,533
Soundproofed version
• Steel chassis • Low noise emissions level • Chassis ready for future mobile kit
installation
• Anti-vibration shock absorbers • Soundproofing provided by
high-density volcanic rock wool • Oil sump extraction kit
• Chassis with integrated fuel tank
• Epoxy polyester powder coating • Versatility to assemble a high capacity
• Fuel level gauge chassis with a metallic fuel tank
• Full access for maintenance (water, oil
• External emergency stop switch and filters, no need to remove the • IP Protection according to ISO
canopy) 8528-13:2016
• Bodywork made from high quality
steel plate • Reinforced lifting hooks for crane • 3 way valve for external fuel supply
hoisting (available in 1/2" and 3/8" fittings) (Opcional).
• High mechanical strength
• Watertight chassis (acts as a double • Fuel transfer pump (Opcional).
barrier against liquid retention) • Steel residential silencer -35db(A)
attenuation. (Opcional).
• Fuel tank drain plug
2020-MAY.-04 18:46
Ctra. Murcia - San Javier, km. 23,6 | 30730 San Javier (Murcia) SPAIN | Tel.: +34 902 19 11 28 / +34 968 19 11 28
Fax: +34 968 19 12 17 | Export Fax +34 968 19 04 20 | E-mail:info@himoinsa.com | www.himoinsa.com
HBW-200 T5
FEATURES OF THE
CONTROL UNITS
CEM 7 CEA 7 CEC 7 CEM7 + CEC7
Voltage between phases • • • •
Voltage between neutral and phase • • • •
Current intensities • • • •
Generator Readings
Frequency • • • •
Apparent power (Kva) • • • •
Active power (Kw) • • • •
Reactive power (kVAr) • • • •
Power factor • • • •
Voltage between phases • • •
Voltage between phases and neutral • • •
Current intensities • • •
Frequency • • •
Mains Readings
Apparent power •
Active power •
Reactive power •
Power factor •
Coolant temperature • • •
Oil pressure • • •
Engine Readings
Ctra. Murcia - San Javier, km. 23,6 | 30730 San Javier (Murcia) SPAIN | Tel.: +34 902 19 11 28 / +34 968 19 11 28
Fax: +34 968 19 12 17 | Export Fax +34 968 19 04 20 | E-mail:info@himoinsa.com | www.himoinsa.com
HBW-200 T5
Short-circuit • • •
Asymmetry between phases • • • •
Incorrect phase sequence • • • •
Inverse power • • •
Overload • • •
Genset signal drop • • • •
Total hour counter • • • •
Partial hour counter • • • •
Kilowatt meter • • • •
Starts valid counters • • • •
Counters
GSM/GPRS modem ⓪ ⓪ ⓪ ⓪
Remote screen ⓪ ⓪ ⓪
Tele signal ⓪ (8 + 4) ⓪ (8 + 4) ⓪ (8 + 4)
J1939 ⓪ ⓪ ⓪
Alarm history • • • •
(10) / (opc. +100) (10) / (opc. +100) (10) / (opc. +100) (10) / (opc. +100)
External start • • • •
Start inhibition • • • •
Mains failure start • • •
Start under normative EJP • • •
Pre-heating engine control • • •
Genset contactor activation • • • •
Mains & Genset contactor activation • • •
Fuel transfer control • • •
Engine temperature control • • •
Manual override • • •
Programmable alarms • • •
Genset start function in test mode • • • •
Features
Programmable outputs • • •
Multilingual • • • •
GPS Positioning ⓪ ⓪ ⓪
Synchronisation ⓪ ⓪ ⓪
Mains synchronization
Special Functions
⓪ ⓪ ⓪
Second Zero elimination ⓪ ⓪ ⓪
RAM7 ⓪ ⓪ ⓪
Remote screen ⓪ ⓪ ⓪
Programming timer ⓪ ⓪ ⓪
2020-MAY.-04 18:46
• Standard Optional
Ctra. Murcia - San Javier, km. 23,6 | 30730 San Javier (Murcia) SPAIN | Tel.: +34 902 19 11 28 / +34 968 19 11 28
Fax: +34 968 19 12 17 | Export Fax +34 968 19 04 20 | E-mail:info@himoinsa.com | www.himoinsa.com
HBW-200 T5
CONTROL
PANELS
M5 AS5
Digital manual Automatic panel
Auto-Start control WITHOUT transfer
panel and thermal switch and
magnetic protection WITHOUT mains
(depending on control with CEM7
current and voltage) unit. (*) AS5 as
and differential with optional with CEA7
CEM7. unit. Automatic panel
without transfer
Digital control unit switch and WITH
CEM7 mains control.
CC2 AS5 +
CC2
Himoinsa Switching
cabinet WITH display. Automatic panel
Digital control unit WITH transfer switch
CEC7 and with mains
control. The display
will be on the genset
and on the cabinet.
Digital control unit
CEM7+CEC7
AC5
Automatic mains
failure control panel.
Wall-mounted
cabinet WITH
transfer switch and
thermal magnetic
protection
(depending on
current and voltage).
Digital control unit
CEA7
Electrical system
• Electric control and power panel • Battery charger (standard on • Starter battery/ies installed
with measurements devices gensets with automatic control (cables and bracket included)
and control unit (according to panels)
necessity and configuration) • Ground connection electrical
• Heating resistor (standard on installation with connection
• Adjustable earth leakage sets with automatic control ready for ground spike (not
protection (time & sensitivity) panels) supplied)
standard in M5 and AS5, with
thermal magnetic protection • Battery charger alternator with • Battery Switch (Opcional).
ground connection
• 3-pole thermal magnetic circuit
breaker
2020-MAY.-04 18:46
Ctra. Murcia - San Javier, km. 23,6 | 30730 San Javier (Murcia) SPAIN | Tel.: +34 902 19 11 28 / +34 968 19 11 28
Fax: +34 968 19 12 17 | Export Fax +34 968 19 04 20 | E-mail:info@himoinsa.com | www.himoinsa.com