Wind Load Calculations
Wind Load Calculations
Wind Load Calculations
01kN
Length = 39.29 m 1 kN = 100 kg
Width/Span = 11.30 m
Bay spacing = 11.68 m
Clear eave height = 12.48 m
Max. eave height = 14.30 m
Roof slope (θ) = 11.03 ˚
DEAD LOAD (DL)
Wt. of sheet & purline = 15.00 Kg/m²
Dead Load (DL) = 1.75 KN/m
ACCIDENTAL LOAD
Collateral Load on Rafter = 20.00 Kg/m² Other Collateral Load = 20.00 Kg/m²
= 2.34 KN/m = 2.34 KN/m
PRESURE COEFFICIENTS:~
Encloser condition of the building = Open
Internal pressure coeff.(Cpi) = 0.70
h/w = 1.27
= 1/2<h/w<=3/2
l/w = 3.48
= 3/2<=l/w<4
External pressure coeff.(Cpe) : Table 4 Table 5
Wind Angle Coeff. For Wall Coeff. For Roof
(ө)
Left Right Left Right
0 degree 0.70 -0.25 -0.9350 -0.40
90 degree -0.80 -0.80 -0.80 -0.80
Wind Across the Ridge (With -Ve Cpi) Wind Across the Ridge (With +Ve Cpi)
-0.24 -17.89 0.30 22.83 -1.64 -124.435 -1.10 -83.72
KN/m
KN/m KN/m KN/m
KN/m KN/m
-114.16 -114.16
-1.50
KN/m -1.50
KN/m
KN/m KN/m
-7.61 0.00
-0.10
KN/m -0.10
KN/m
Note:
1) Values within the circles are the UDL
2) -Ve value means, load applied
away from structure.