Schlumberger @ Balance
Apache HPU
A
13-007 Operations Manual
2/26/2013
Replacement Filters
Pressure Elements No.: 36012301
Return Line Element No.: 36040337
Breather Element No.: 50340121
Recommended Change Interval: Every 2000 Working Hours
Recommended Cleanliness Code: ISO 16/14/11
(Oil must be filtered into unit)
Fluid Specification
Mineral Based AW Hydraulic Oil, Fina Biohydran 68 or Equal
WARNING:
This unit contains hydraulic accumulators pre-charged with Nitrogen
Do not service this unit unless all hydraulic and electrical sources that intersect with this
system are completely shut down.
Operating Pressure:
o 1350 - 1500 psig
Operating Flow Rate:
o 1.5 gpm
System Operation
The following steps must be followed for proper and safe operation.
Figure 1
1. Verify that the low level light is not on. If it is, follow step 6, check for leaks, and fill the
reservoir to the top of the sight glass with oil. See Figure 2.
Figure 2
2. Verify that the high temperature light is not on. If it is, the oil must be cooled to below
150° F before the unit will run again.
3. Verify that the oil temperature is 70° F or higher by reading the thermometer in the sight
glass. See Figure 2. If it isn’t, let the heater heat the oil to 70° F before operating.
4. Start the motor and let it run for a minute before closing the main system needle valve
(Item 18). The system will begin to build pressure when the main system needle valve
(item 18) is closed.
5. When done using the unit open the main system needle valve (Item 18) to return the oil
in the main system to the reservoir.
13-007 Operations Manual
2/26/2013
Air Pump
Jam Nut
Relief Valve
Figure 3
Electric Pump
Relief Valve
Jam Nut
Figure 4
13-007 Operations Manual
2/26/2013
Unloading Valve
Jam Nut
Figure 6
13-007 Operations Manual
2/26/2013
Trouble Table
Problem Checks/Reminders Corrective Action
Push Start Button But Do you have power on the unit? If no, connect 3P 480V to
Nothing Happens the enclosure.
Is the suction ball valve open? If no, open the ball valve.
Is the low level light on? If yes, check for leaks and fill
the reservoir to the top of
the sight glass (make sure
that the accumulators are
dumped before doing so).
Is the high temperature light on? If yes, the oil must cool
before the unit will start
again.
Was Running but Is the low level light on? If yes, check for leaks and fill
Shutdown the reservoir to the top of
unexpectedly the sight glass (make sure
that the accumulators are
dumped before doing so).
Is the high temperature light on? If yes, the oil must cool
before the unit will start
again.
Is the suction ball valve open? If no, open the ball valve.
Is Running but will not Does the pump rotate in the proper direction? Check by removing the coupler
build pressure cover. Have someone turn the
anywhere motor on & off quickly so you
can see the motor spin to a stop
or spin to a start.
Is the accumulator dump needle valve closed? If no, close the needle valve to
stop the flow from going back
to the reservoir.
Do you have any major leaks? If yes, fix the leaks and fill the
reservoir to the top of the
sight glass (make sure that
the accumulators are
dumped before doing so).
Section B – Hydraulics
B
8 7 6 5 4 3 2 1
F
F
E E
22.000 23.000
D D
C C
70.188
B B
MATERIAL
.0005
MFG APPR.
CUST APPR.
Reservoir 13-007
DRAWING IS THE SOLE PROPERTY OF DWG. NO. REV
Varies
0
CONTROLLED FLUIDS, INC. ANY COMMENTS:
REPRODUCTION IN PART OR AS A WHOLE FINISH
WITHOUT THE WRITTEN PERMISSION OF Varies 11213007
CONTROLLED FLUIDS, INC. IS
PROHIBITED. SCALE: 1:10 WEIGHT: 235.78 LBS SHEET 1 OF 1
8 7 6 5 4 3 2 1
Extended Range
T.R.A.P.™ Breather Technology
Donaldson T.R.A.P. breathers are available in a variety of configurations:
t ABS plastic, nylon or epoxy-coated steel construction
t NPT, BSP, UN straight thread or bayonet connections
t With and without electronic indicator options to fit a broad range of applications
Ø4.50" [114mm]
4.52" [115mm]
6.56
6.56
[166.5mm]
1 6 65
.
1.38" [35mm]
3.38
3.38
8 58
.
[85.8mm] 1" NPT
Bayonet Adaptor
Metal P565858 Top View P565857 (3/4" NPT version, optional mechanical)
P566037 (3/4" BSP version)
Ø3.18" [81mm]
1.56" [40mm]
1.70" [43mm]
2.87" [73mm]
Bayonet
3/4" NPT or 3/4" BS
1.20" [30mm]
2.41" [61mm]
1.36"
34.5
1.36
[34mm]
2.18"
55.5
[55mm] 1.65
Bayonet Flange
Bayonet Flange
Bayonet Flange Gaskets
Gaskets
Mounting Hardware
Mounting Hardware 4.50" [114mm]
3.68" [93mm] 6.74" [171mm]
Technical Features
Particulate Filter
t Highly efficient pleated particulate filter
stops particle sizes down to 3 μm at 97%.
Service Interval
t Optional mechanical indicator available
Models with no indicator: change breather
every 6 months.
Electronic Indicator
t Actuated by pressure differential, flashes
red to indicate change out is needed.
Low Restriction to Air Flow Indicator setting, 1 PSID (6.9kPa).
(lpm)
t Indicator power source: 3V lithium
battery CR2032.
Pressure Drop Return (in H2O)
Standard
Mechanical Indicator Kit
(kPa)
730
720
E E
710
670
650
680
D D
Black Black
700
B B
660
620
610
E E
570
550
580
D D
590
C C
31.319
WIRE SWITCH
Red Red
White Green
B Cut Black B
600
Immersion Heaters
Features
• Keeps oil at 60° to 70° F.
• Automatic built-in fixed setting thermostat normally closed
• Will not burn oil
• UL recognized and CSA certified
• Weatherproof wiring enclosure (NEMA 4)
Notes
1. Heaters must be mounted horizontally and
immersed at all times.
2. Heaters over 10 amps, 480 volt, or three phase,
must be used with a contactor. See instruction sheet.
3. Three phase available on ET 8 models.
Add -3 to the model number. Example: ET 8-2502-3.
4. For tanks larger then 500 gallon use multiple heaters
or consult factory for information on higher wattage
heaters.
5. Amps = Watts ÷ Volts for single phase.
6. Amps = Watts ÷ (Volts x 1.73) for three phase.
NOTE: WITH VESCORS' POLICY OF CONSTANTLY IMPROVING ITS PRODUCTS, SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE. 62
1 JULY 03
120 or 240 VOLT
INSTALLATION AND WIRING SINGLE PHASE
INSTRUCTIONS FOR
ET HYDRAULIC OIL HEATERS
T60 THERMOSTAT
VESCOR (OPTIONAL)
50 N. River Street
South Elgin, IL 60177
847-742-7270
Fax 847-742-5187
D
No.:
Date: 01-JUN-2012
Customer :
TECHNICAL PROPOSAL
Notes:
Date: 01-JUN-2012
DATA SHEET
Three-phase induction motor - Squirrel cage rotor
Customer :
Product line : Three-Phase : Explosion Proof - NEMA Premium
Frame : 145T
Output : 2 HP
Frequency : 60 Hz
Poles : 4
Full load speed : 1750
Slip : 2.78 %
Voltage : 208-230/460 V
Rated current : 6.02-5.44/2.72 A
Locked rotor current : 43.0/21.5 A
Locked rotor current (Il/In) : 7.9
No-load current : 3.00/1.50 A
Full load torque : 5.92 lb.ft
Locked rotor torque : 250 %
Breakdown torque : 320 %
Design : B
Insulation class : F
Temperature rise : 80 K
Locked rotor time : 11 s (hot)
Service factor : 1.15
Duty cycle : S1
Ambient temperature : -20°C - +40°C
Altitude : 1000
Degree of Protection : IP54
Approximate weight : 55 lb
Moment of inertia : 0.15947 sq.ft.lb
Noise level : 51 dB(A)
Notes:
Performed by Checked
No.:
Date: 01-JUN-2012
C - Slip
C
90 0.9 1.0
80 0.8 A 2.0
70 0.7 3.0
60 0.6 4.0
50 0.5 B 5.0
6
A - Efficiency (%)
B - Power factor
D 4
0
0 10 20 30 40 50 60 70 80 90 100 110 120 130
Percent of rated output (%)
Customer :
Product line : Three-Phase : Explosion Proof - NEMA Premium
Notes:
Performed by Checked
No.:
Date: 01-JUN-2012
4.0 B 8.0
A - Torque related to rated torque (C/Cn)
3.5 7.0
A
3.0 6.0
2.5 5.0
2.0 4.0
1.5 3.0
1.0 2.0
0.5 1.0
0.0 0.0
0 10 20 30 40 50 60 70 80 90 100
Speed related to rated speed (%)
Customer :
Product line : Three-Phase : Explosion Proof - NEMA Premium
Notes:
Performed by Checked
1 2 3 4 5 6 7 8
Notes:
E
Performed by:
2E 2F H BA A Checked:
5.500 5.000 0.344 2.250 6.457
B C D G J Customer:
6.142 13.752 3.500 0.429 1.496
K O P ES S Three-Phase : Explosion Proof - NEMA Premium
1.654 7.000 7.000 1.575 0.187
F N-W U R AB AA
2.250 0.875 0.765 6.811 NPT 3/4"
d1 Flange AJ AK BD
A4 FC-149 5.875 4.500 6.500 Three-phase induction motor 01-JUN-2012
BF BB BC AH Frame 145T - IP54
UNC 3/8"x16 0.156 0.125 2.125
with 11 displacement sizes from 0.07 to .82 cu.in/rev. (1.3 to 6.1 cm3/rev).
GP - F10 - 20 - P - C
Aluminium High Displacement Drive Rotation
Horizontal Pump/Motor Mounts
Horizontal Mount Selection Method
1. Check TABLES 2 thru 5 to determine pump flange size.
2. Measure the pump shaft length from the shaft end to the flange mounting face and ADD to the motor shaft length shown
in TABLE 6. An additional 1/16 inch (minimum) is recommended for shaft end clearance.
3. Refer to the appropriate TABLE (7 thru 11) according to the NEMA motor frame size and locate the applicable pump
flange selection form STEP 1, above.
4. Select the mount length option (dimension ‘XM’ or ‘M’ in tables) based on the minimum length determined in STEP 2,
above.
5. Check for proper clearance between the mount inner surfaces and the coupling O.D. (dimension ‘Z’ and ‘CL’ in tables).
Dimensional data for Magnaloy Couplings is shown in TABLE 1 for reference. A complete Magnaloy Coupling catalog is
available upon request or visit www.magnaloy.com.
Consult your Magnaloy Distributor for Magnaloy’s Product CD ROM which includes the Magnaloy Pump/Motor Mount
Selection Program for easy, computerized mount selection.
XAK XAJ2 XBF2 XAJ4 XBF4 MOUNT NO. CL XM MOUNT NO. CL XM MOUNT NO. CL XM
16
88
81
50
7/
5.
6.
4.
USA4F17 4 Bolt 1.782 2.84 5/16-18 M056354F 2.81 3.50 M056424F 3.56 4.25 M056454F 3.81 4.50
SAE AA 2 Bolt 2.001 3.25 3/8-16 M056352AA 2.81 3.50 M056422AA 3.56 4.25 M056452AA 3.81 4.50
SAE 2A 2(4) Bolt 3.251 4.19 3/8-16 4.12 3/8-16 M056352A 2.81 3.50 M056422A 3.56 4.25 M056452A 3.81 4.50
80 2A/B4 2(4) Bolt 80.01mm 109mm 3/8-16 103mm 5/16-18 M0563580M 2.81 3.50 M0564280M 3.56 4.25 M0564580M 3.81 4.50
80 S4 4 Bolt 80.01mm 100mm 5/16-18 M0563580MS 2.81 3.50 M0564280MS 3.56 4.25 M0564580MS 3.81 4.50
PUMP FLANGE PUMP END DATA 3.50 LENGTH 4.25 LENGTH 4.50 LENGTH
81
50
7/
5.
6.
4.
USA4F17 4 Bolt 1.782 2.84 5/16-18 M056504F 4.31 5.00 M056524F 4.56 5.25
SAE AA 2 Bolt 2.001 3.25 3/8-16 M056502AA 4.31 5.00 M056522AA 4.56 5.25
SAE 2A 2(4) Bolt 3.251 4.19 3/8-16 4.12 3/8-16 M056502A 4.31 5.00 M056522A 4.56 5.25
SAE 2B 2(4) Bolt 4.001 5.75 1/2-13 5.00 1/2-13 M056502B* 3.93 5.00 M056522B* 4.18 5.25
80 2A/B4 2(4) Bolt 80.01mm 109mm 3/8-16 103mm 5/16-18 M0565080M 4.31 5.00 M0565280M 4.56 5.25
80 S4 4 Bolt 80.01mm 100mm 5/16-18 M0565080MS 4.31 5.00 M0565280MS 4.56 5.25
80 S4 4 Bolt 80.01mm 100mm 5/16-18 M05650100M* 3.93 5.00 M05652100M* 4.18 5.25
PUMP FLANGE PUMP END DATA 5.00 LENGTH 5.25 LENGTH
magnaloy coupling company P.O. Box 455 Alpena, MI 49707 989 356-2186 5
A Division of Douville Johnston Corporation Fax: 989 354-4190 http://www.magnaloy.com
Premium Flexible Drive Couplings
magnaloy coupling company P.O. Box 455 Alpena, MI 49707 989 356-2186 3
A Division of Douville Johnston Corporation Fax: 989 354-4190 http://www.magnaloy.com
Dimensional Specifications
Magnaloy Coupling Dimensional Specifications
Model 500
500
A 4.67
B 4.800 X*: Maximum Space between
shaft ends to allow full
C 4.00
shaft engagement in
D 1.04 Hub Bore.
E 1.23
F .064 W*: Minimum Space between
shaft ends.
G .070
W 1/16 * Given for reference only.
X 1.41
T 3/8-16 TOLERANCES: 2 Place Decimals ± .01
3 Place Decimals ± .001
4 magnaloy coupling company P.O. Box 455 Alpena, MI 49707 989 356-2186
A Division of Douville Johnston Corporation Fax: 989 354-4190 http://www.magnaloy.com
Bore & Keyway Combinations
Standard Bore and Keyway Combinations
Magnaloy “Standard” Bore Key Combinations Magnaloy “Standard” Bore Key Combinations
Model Bore/Key Model Model Bore/Key Model
Code Code Bore Key Code Code Bore Key
100
200
300
400
500
600
700
800
900
100
200
300
400
500
600
700
800
900
M _ _ _ 01203 3/8 x 3/32 * * M _ _ _ 12414 1 3/4 x 7/16 * * * * *
M _ _ _ 01403 7/16 x 3/32 * * M _ _ _ 12816 1 7/8 x 1/2 * * * * * *
M _ _ _ 01404 7/16 x 1/8 * * M _ _ _ 13016 15/16 x 1/2 * *
M _ _ _ 01604 1/2 x 1/8 * * * M _ _ _ 20016 2 x 1/2 * * * * *
M _ _ _ 01804 9/16 x 1/8 * * * M _ _ _ 20416 2 1/8 x 1/2 * * * * *
M _ _ _ 02005 5/8 x 5/32 * * * M _ _ _ 20816 2 1/4 x 1/2 * * * * *
M _ _ _ 02006 5/8 x 3/16 * * * * M _ _ _ 21220 2 3/8 x 5/8 * * * * *
M _ _ _ 02206 11/16 x 3/16 * * * * M _ _ _ 21620 2 1/2 x 5/8 * * * *
M _ _ _ 02404 3/4 x 1/8 * * * M _ _ _ 22020 2 5/8 x 5/8 * * * *
M _ _ _ 02406 3/4 x 3/16 * * * * * * M _ _ _ 22420 2 3/4 x 5/8 * * *
M _ _ _ 02806 7/8 x 3/16 * * * * * * M _ _ _ 22824 2 7/8 x 3/4 * * *
M _ _ _ 02808 7/8 x 1/4 * * * * * * M _ _ _ 30024 3 x 3/4 * *
M _ _ _ 03008 15/16 x 1/4 * * * M _ _ _ 30824 3 1/4 x 3/4 * *
M _ _ _ 10006 1 x 3/16 * * * * * * M _ _ _ 31228 3 3/8 x 7/8 * *
M _ _ _ 10008 1 x 1/4 * * * * * * M _ _ _ 31628 3 1/2 x 7/8 * *
M _ _ _ 10408 1 1/8 x 1/4 * * * * * * M _ _ _ 32028 3 5/8 x 7/8 * *
M _ _ _ 10608 1 3/16 x 1/4 * * M _ _ _ 32428 3 3/4 x 7/8 * *
M _ _ _ 10808 1 1/4 x 1/4 * * * * * M _ _ _ 32832 3 7/8 x 1 * *
M _ _ _ 10810 1 1/4 x 5/16 * * * * * * * M _ _ _ 40032 4 x 1 *
M _ _ _ 11210 1 3/8 x 5/16 * * * * * * * M _ _ _ 40432 4 1/8 x 1 *
M _ _ _ 11212 1 3/8 x 3/8 * M _ _ _ 40832 4 1/4 x 1 *
M _ _ _ 11412 1 7/16 x 3/8 * * * M _ _ _ 41232 4 3/8 x 1 *
M _ _ _ 11610 1 1/2 x 5/16 * * * M _ _ _ 41632 4 1/2 x 1 *
M _ _ _ 11612 1 1/2 x 3/8 * * * * * * M _ _ _ 41640 4 1/2 x 1 1/4 *
M _ _ _ 12012 1 5/8 x 3/8 * * * * * * M _ _ _ 42040 4 5/8 x 1 1/4 *
M _ _ _ 12412 1 3/4 x 3/8 * * * * * M _ _ _ 42440 4 3/4 x 1 1/4 *
Shaded Area: AGMA semi-standard bore key combinations.
Part Number Usage: Magnaloy Coupling Hub part numbers may be specified Bore Tolerances
using the following format: Start with letter “M” designating Magnaloy, Over Include Tolerance
followed by 3 digit Model Code (100, 200, etc.), then the specific 5 digit -- 1 +.0008/+.0003
Bore/Key Code. 1 2 +.0013/+.0005
2 3 +.0018/+.0008
Example: Model 500 Hub with a 1 /38 bore and 5/16 keyway would be 3 4 +.0020/+.0010
4 5 +.0023/+.0010
specified as: M50011210 - No bore hubs are designated as “R” code, ie.
M500R.
Additional Coupling Specifications
Model Number 100 200 300 400 500 600 700 800 900
Maximum Bore 1 1/8 1 3/8 1 5/8 1 7/8 2 3/8 2 5/8 2 7/8 3 7/8 4 3/4
Complete Coupling Approx. Weight
3/4 1 2 3 4 7 12 18 38
(Solid Hub)
Number of Drive Lugs 3 3 3 3 4 6 6 6 6
Hub Movement for Insert Removal .74 .74 .75 .98 1.12 1.02 1.50 1.63 2.27
Basic Insert Number 170 270 370 470 570 670 770 870 970
magnaloy coupling company P.O. Box 455 Alpena, MI 49707 989 356-2186 5
A Division of Douville Johnston Corporation Fax: 989 354-4190 http://www.magnaloy.com
Insert Selection Guide
8 magnaloy coupling company P.O. Box 455 Alpena, MI 49707 989 356-2186
A Division of Douville Johnston Corporation Fax: 989 354-4190 http://www.magnaloy.com
Coupling Selection Guide
Service Factors - Load Characteristics
Type of Prime Mover
Load Standard Motor High Torque I.C. Engine I.C. Engine
Classification or Turbine Motor 6 or more cyl. less than 6 cyl.
Uniform (U) 1.0 1.5 1.5 2.0*
Moderate (M) 1.5 2.0 2.0 2.5*
Heavy (H) 2.0* 2.5* 2.5* 3.0*
Uniform Load: Steady loading, non-reversing, torque does not exceed rating.
Moderate Load: Uneven loading with moderate shock, frequent starts, infrequent reversals,
peak torque may exceed average rating of prime mover by up to 125%.
Heavy Load: Uneven loading with heavy shock, frequent reversals, peak torque may exceed
average rating of prime mover by up to 150%.
* Recommend use of Hytrel Insert.
magnaloy coupling company P.O. Box 455 Alpena, MI 49707 989 356-2186 9
A Division of Douville Johnston Corporation Fax: 989 354-4190 http://www.magnaloy.com
Test 20 Typ SMK Connection Thread M 16 x 2
Advantages:
• Coupling at system pressure level
• Leakproof connection before ball valve is open
Test hose • Simple connection to measuring,
with swivel nut control and switching devices
• Self locking metal guard cap
Working pressure:
• Max. working pressure 630 bar
For SMK style G, K and S the recommended working
pressure of fitting manufacturer has to be applied
• Joining under pressure up to 400 bar max.
Materials:
• Metal parts: Steel, Stainless Steel on request
Test coupling • Ball: Stainless Steel
• Seals:
P = NBR (Temperature range – 20° C to + 90° C)
V = FPM (Temperature range – 20° C to + 200° C)
E = EPDM Ethylene Propylene (for Break Fluid)
Temperature range – 40° C to + 150° C
• Hose: Polyamide (Temperature range -35° C . . . 100° C
max.)
Media:
• Suitable for hydraulic oils and other mineral oil based fluids
(Please pay attention to the sealing materials used !)
Protective cap • For use in conjunction with other liquid media please
consult STAUFF
M 16
M 14 x 1,5 37 19 SMK 20 – M 14 x 1,5 – PB SMK 20 – M 14 x 1,5 – VB Metal joint Type B
SW G /8 1
39 17 SMK 20 – G 1/8 – PC SMK 20 – G 1/8 – VC O-Ring Type C
G G /8 3
37 22 SMK 20 – G /8 – PB 3
SMK 20 – G /8 – VB 3
Metal joint Type B
R /8 taper
1
37 17 SMK 20 – R /8 K-PD 1
SMK 20 – R /8 K-VD 1
Taper Type D
R 1/4 taper 36 17 SMK 20 – R 1/4 K-PD SMK 20 – R 1/4 K-VD Taper Type D
1
/8 NPT 36 17 SMK 20 – 1/8 NPT-PD SMK 20 – 1/8 NPT-VD Taper Type D
1
/4 NPT 35 17 SMK 20 – /4 NPT-PD
1
SMK 20 – /4 NPT-VD
1
Taper Type D
5
/16 – 24 UNF 38 17 SMK 20 – /16 UNF-PE
5
SMK 20 – /16 UNF-VE
5
O-Ring Type E
17 10 7
/16 – 20 UNF 38 17 SMK 20 – 7/16 UNF-PE SMK 20 – 7/16 UNF-VE O-Ring Type E
1
/2 – 20 UNF 38 17 SMK 20 – 1/2 UNF-PE SMK 20 – 1/2 UNF-VE O-Ring Type E
9
/16 – 18 UNF 37 19 SMK 20 – /16 UNF-PE
9
SMK 20 – /16 UNF-VE
9
O-Ring Type E
Other port connections and seals on request.
d2
d1 d1
d1 30° 12°
G G G d1
G 90° 90° 90°
1,6
G
0,5
2,5
a
t1
t1
t1
t1
t1
t2
t2
t2
t2
t2
G d1 t1 t2 G d1 t1 t2 a G d1 t1 t2 a G t1 t2 G d1 d2 t1 t2 a
M8 x 1 9,5 + 0,1 11 15,5 M 14 x 1,5 20 12 18,5 1,5 M 12 x 1,5 18 12 18,5 1,5 R /8 taper
1
5,5 9,5 /16 – 24 UNF
5
9,1 17 10,0 12,0 1,9
M 10 x 1 11,5 + 0,1 12 16,5 M 16 x 1,5 22 12 18,5 1,5 G 1/8 15 8 13,0 1,0 R 1/4 taper 8,5 13,5 /16 – 20 UNF 12,4
7
21 11,5 14,0 2,4
h
SW19 1) 72
M18 x 1.5 2.8 B SSK 20/12 L–P SSK 20/12 L–V
max. 12
max. 12
h
(1/2")
(1/2")
7/16 UNF 63
SW19
SW19
(– 4 JIC) A N/A SSK20–J7/16UNF–MV
2.48
TEST
Type A G Type B
54
G 1/4 19
.75 SMA 20 – G /4 – P-OR SMA 20 – G /4 – V-OR
1 1
2.12
64
G 1/2 27
1.06 SMA 20 – G /2 – P-OR SMA 20 – G /2 – V-OR
1 1
2.52
h
54
1/4 NPT 19 SMA 20 – 1/4 NPT–V
SW19
.75 SMA 20 – /4 NPT–P
1
2.12
1/ 64
NPT 27 SMA 20 – 1/2 NPT–V
Mounting hole 2 2.52 1.06 SMA 20 – 1/2 NPT–P
Ø 18 mm Snubber on request
M16 (0.17")
h SW Order No.
(Add C6F for Standard Finish)
G G
mm mm
NBR (BUNA) FPM (VITON)
in in (Standard)
41
G 1/4 19
.75 SMD 20 – G /4 – P-OR SMD 20 – G /4 – V-OR
1 1
SW
1.61
51
G 1/2 27
1.06 SMD 20 – G /2 – P-OR SMD 20 – G /2 – V-OR
1 1
2.0
h
41
1/4 NPT 19 SMD 20 – 1/4 NPT
.75 SMD 20 – /4 NPT
1
1.61
1/2 NPT 51 27 SMD 20 – 1/2 NPT
1.06 SMD 20 – /2 NPT
1
2.0
41
7/16 – 20 UNF 19 — SMD 20 – 7/16 UNF
1.61 .75
M16 5.68
—
Snubber on request
37°
Ød1
Ød2
T7
u
8 7 6 5 4 3 2 1
10.250
11.000
2.000
5.500
6.375
9.000
.672
0
0
.750
F
F .625 Drill x .750
1.750
.250 Drill x 2.250 .625 Drill x .750
3.000
3.250 3x #4 SAE Port
4.328
4.500
4.531
5.000
.250 Drill x 2.500
.250 Drill x 2.875
.500 Drill x 2.375
E E
4x #8 SAE Port
5.000
11.000
.672
3.000
4.500
4.625
5.250
6.000
6.375
9.000
1.000
1.907
3.125
5.000
.375
0
0
Sun Cavity T-13A
0 #8 SAE Port 0 Locating Shoulder .031" 0
from surface
.500 Drill x 1.875 .531 Drill x 4.250
1.000
1.750 #8 SAE Port
2.000 Sun Cavity T-21A 1.750
Locating Shoulder 1.188" 1.813
2.170 from surface
2.375 2.375 2.400 #12 SAE Port
.531 Drill Thru 2.500
2.625
3.500
D .250 Drill x 1.075 D
3.750
.250" Drill x 3.125
4.500 4.500 4.500
.875 Drill x 5.250
Sun Cavity T-162A .250 Drill x .750
Sun Cavity T-162A Locating Shoulder .031" Sun Cavity T-11A .625 Drill x 8.000
Locating Shoulder .031" from surface 3x #4 SAE Port Locating Shoulder .688"
from surface from surface .250 Drill x 4.750
.406 Drill x 1.900
.406 Drill x 3.000 .531 x 3.250 #2 SAE Port
.250 Drill x 2.375
11.000
3.000
4.875
5.500
5.750
9.000
Sun Cavity T-8A #4 SAE Port
0
1.407
#4 SAE Port
1.907
.625 Drill x 2.875 .250 x 2.250
3.125
4.250
B
5.000
.625 Drill Thru B
#2 SAE Port 3x #8 SAE Port
Spot Face .125"
11.000
1.375
2.000
2.625
4.688
5.750
6.313
8.375
9.000
9.625
0
0
.469
.500
.750
.625 Drill x 4.500
UNLESS OTHERWISE SPECIFIED: NAME DATE
(800) 722-2630
2.330 DIMENSIONS ARE IN INCHES MODELED BY JAK 01/30/13 (409) 833-2630
TOLERANCES: 2220 Calder Ave.
FRACTIONAL 1/16"
DRAWN BY JAK 01/31/13 Beaumont, Texas 77701
A
.625 Drill x 2.000 .625 Drill x 3.500 ANGULAR 1/2 "
OSS APPR. www.confluids.com A
3.580 DECIMALS:
.X .05 ENGR APPR. GJH 02/01/13
4.000 8X .257 .903 .XX .015 TITLE:
CUST APPR.
Manifold 13-007-1M PMSI
4.500 DRAWING IS THE SOLE PROPERTY OF DWG. NO. REV
6061-T6 (SS)
0
COMMENTS:
4X .313 1.063 .188 Drill x 3.750 CONTROLLED FLUIDS, INC. ANY
Applications
■ Chemical, Petrochemical
■ Oil and gas refining
■ Food industry
■ Mechanical engineering
Special Features
Description
Approvals meet international standards The IS-21-S and IS-21-F transmitters feature a flush
The IS-20 series of intrinsically safe pressure transmitters diaphragm process connection. They are specifically
are designed for industrial pressure measurement designed for the measurement of viscous fluids or media
applications in hazardous areas where intrinsically safe rat- containing solids that may clog a NPT process connection.
ings are required.
Types IS-20-F and IS-21-F feature an integral stainless steel
Multiple intrinsically safe approvals include FM, ATEX junction box with internal terminal block for use in extremely
and CSA. These multiple approvals provide for global harsh environments. A ½“ NPT female conduit connection is
recognition and acceptance of the intrinsically safe ratings. standard on all models and a cable compression electrical con-
The transmitters are labeled with all three approvals to help nection is available as an option.
support international shipments of OEM equipment
designed with these transmitters. All types require a 10 to 30 volt supply provided by an
intrinsically safe power supply or through an approved
Rugged construction
intrinsically safe zener diode barrier.
The stainless steel wetted parts feature an all-welded mea-
suring cell for improved media compatibility. There are no
internal soft sealing materials that may react with the media
or deteriorate over time. The compact case is also made of
stainless steel and is available with environmental protection
ratings up to NEMA 6 ( IP 68).
Datasheet IS-20, IS-21 · 1/2011 Page 1 of 8
R
Specifications Type IS-20-S, IS-21-S, IS-20-F, IS-21-F
*) In an oxygen version type IS-21 is not available. In an oxygen version type IS-20 is only available in gauge pressure ranges ≥ 0.25 bar with media temperatures between
-20 … +60 °C / -4 … +140 °F and using stainless steel or Elgiloy® wetted parts.
{ } Items in curved brackets are optional extras for additional price.
permissible range
permissible range
Supply
Voltage
4 ... 20 mA: RA < (UB – 10 V) / 0.02 A 4 ... 20 mA: RA < (UB – 11 V) / 0.02 A
1.77“ (45mm) ) )
* *
1.73” 44mm)
.71” 18mm)
1.69“ (43mm)
1.14“ (29mm)
1.06“
(27mm)
.85”(21.5mm)
.79”(20mm)
.85”(21.5mm)
.12”(3mm)
1.08”(27.5mm)
.51”(13mm)
O.20”
(19mm)
O .24”
.51”(13mm)
.08”(2mm)
.08”(2mm)
.75”
(5mm)
.12”(3mm)
(6mm) O.37”
1/2NPT O .69” (9.5mm)
(17.5mm)
2.
1.00”(25.5mm)
41
2.60”(66mm)
”(6
1m
m
1.24”(31.5mm)
)
Other connections
available 1/2” NPT female conduit
4.41”(112mm)
Case dimensions
2.13”(54mm)
1.06”(27mm)
1.06”(27mm)
1.52”(38.5mm)
Sealing ring
.81”(20.5mm)
Sealing ring
1.22”(31mm)
.81”(20.5mm)
.98”(25mm)
29.7x35.7x2.0
.39”(10mm)
O-ring 21.82x3.53
Matching P-1 weld insert adapters for IS-21-S and IS-21-F transmitters
weld
3.66”(93mm)
3.27”(83mm)
1.79”(45.5mm)
1.22”(30.9mm)
.75”(19mm)
.81”(20.5mm)
.75”(19mm)
sealing ring 18,5x23,9x1,5
.39”(10mm)
O-ring 15.0x2,0
B C
A
Media Temperature in °C
Version A B C
Cooling fins 2 3 5
K* 0.47 0.68 0.76
Wiring details
L-connector Circular connector Cable,
DIN 175301-803 A M12x1, 4 pin 1.5 m
Group I: Electrical equipment for use in mines (hazard due to mine gas)
The specifications given in this document represent the state of engineering at the time of publishing.
We reserve the right to make modifications to the specifications and materials.
Specifications and dimensions given in this data sheet represent the state of engineering at the time of printing.
Modifications may take place and materials specified may be replaced by others without prior notice.
Product Description
Needle valves are fully adjustable orifices used to regulate flow. They are infinitely adjustable from fully closed up to the maximum
orifice diameter. They are not pressure-compensated. They may be used as flow controls or as shutoff valves.
Download
Technical Features
All 2-port flow control cartridges are physically and functionally The sharp-edged orifice design minimizes flow variations due to
interchangeable (i.e. same flow path, same cavity for a given frame viscosity changes.
size). However, cartridge extension dimensions from the mounting
surface may vary.
Because needle valves are non-compensating devices, the fixed orifice The flow path through this valve is bi-directional. The preferred path is
size will regulate flow through the valve in proportion to the square root port 1 to 2, to allow interchangeability with other flow controls.
of the pressure differential across ports 1 and 2.
A balanced adjustment mechanism allows for easy adjustment even at There is no leakage when the adjustment mechanism is turned to the
high pressures. shut-off position.
Special Notes
For cartridges configured with an O control (panel mount handknob), a .75 in. (19 mm) diameter hole is required in the panel.
Technical Data
U.S. Units Metric Units
Cavity T-13A
Capacity .19 in. 4,8 mm
Adjustment - Number of Counterclockwise Turns - Fully Closed to Fully Open 5
Maximum Operating Pressure 5000 psi 350 bar
Series (from Cavity) Series 1
Valve Hex Size 7/8 in. 22,2 mm
Valve Installation Torque 30 - 35 lbf ft 40 - 50 Nm
Adjustment Screw Internal Hex Size 5/32 in. 4 mm
Adjustment Locknut/Cap Hex Size 9/16 in. 15 mm
Adjustment Nut Torque 80 - 90 lbf in. 9 - 10 Nm
Seal Kits - Cartridge Buna: 990-010-007
Seal Kits - Cartridge Viton: 990-010-006
Model Weight 0.32 lb. 0.15 kg.
NFCC-LCN
Material/Coating
Control Maximum Orifice Diameter Seal Material
Modifier
Preferred Options Preferred Options Preferred Options Preferred Options
L Standard Screw Adjustment C .19 in. (4,8 mm) N Buna-N No modifier (standard material
Standard Options Standard Options Standard Options with no special coating)
Special Options
K Handknob Control: L
Control: Y
Our corrosion resistant product
line is growing! If you are
interested in a corrosion
resistant option for this model,
please contact Sun.
APPLICATIONS
• Hy-Pro Low pressure TFR series filters are ideal for
installation on the return line to remove contaminant
ingested or generated by the system.
• Power units
• Mobile equipment
www.hyprofiltration.com
TFR FILTER ASSEMBLY SELECTION AND SIZING GUIDELINES
Effective filter sizing requires consideration of flow rate, viscosity (operating and cold start), fluid type and degree of filtration.
When properly sized, bypass during cold start can be avoided/minimized and optimum element efficiency and life achieved. The
filter assembly differential pressure values provided for sizing differ for each media code, and assume 150 SSU (32Cts) viscosity
and 0.86 fluid specific gravity. Use the following steps to identify the correct high pressure filter assembly.
2. Calculate actual clean filter assembly ∆p at both operating and cold start viscosity:
Actual assembly clean ∆p = Flow rate x ∆p Coefficient x Assembly ∆p factor (from sizing table)
• To avoid or minimize bypass during cold start the actual assembly clean ∆p calculation should be repeated for start-up
conditions if cold starts are frequent.
• Actual assembly clean ∆p should not exceed 5 psid at normal operating viscosity.
• If suitable assembly size is approaching the upper limit of the recommended flow rate at the desired degree of filtration
consider increasing the assembly to the next larger size if a finer degree of filtration might be preferred in the future. This
practice allows the future flexibility to enhance fluid cleanliness without compromising clean ∆p or filter element life.
• Once a suitable filter assembly size is determined consider increasing the assembly to the next larger size to optimize filter
element life and avoid bypass during cold start.
• When using water glycol or other specified synthetics we recommend increasing the filter assembly by 1~2 sizes.
• High viscosity fluid (ie gear lube ISO 220) will typically display very high viscosity as the temperature drops below 100f.
For such applications avoiding bypass during start-up might not be possible.
www.hyprofiltration.com
TFR
TFR FILTER ASSEMBLY SELECTION AND SIZING GUIDELINES
www.hyprofiltration.com
TFR ASSEMBLY PART NUMBER GUIDE
TFR
HPTFR L - -
BOLD text denotes standard options for each size (TFR1, TFR2, TFR3) that are
available for quick shipment. Non-standard options are subject to longer lead times.
Hy-Pro filters are tested to the latest industry New (ISO16889) vs Old (ISO4572) size comparison
standard ISO16889 (replacing ISO4572) resulting in
βx(c)=1000 (ISO16889) 2.5 5 7 12 22
A new scale for defining particle sizes and determining
filtration ratio (formerly known as beta ratio) βx=200 (ISO4572) <1 3 6 12 25
www.hyprofiltration.com
TFR
TFR MOUNTING FLANGES
www.hyprofiltration.com
TFR1 INSTALLATION DRAWING
Length Dimension
Code IN (MM)
(Table 4) A B C D E F G H I J
1.1 (28) or 1" or 4.96
6 7.80 (198) 1.50 (38,1) 3.55 (90,2) 2.68 (68) 11.85 (301) 0.24 (6) 3.50 (89)
1.26 (32) 1 1/4" (126)
1.1 (28) ~ 1" or 4.96
8 9.85 (250,2) 1.50 (38,1) 3.55 (90,2) 2.68 (68) 13.80 (350,5) 0.24 (6) 3.50 (89)
1.26 (32) 1 1/4" (126)
1.1 (28) ~ 1" or 4.96
11 13.8 (350,5) 1.50 (38,1) 3.55 (90,2) 2.68 (68) 18.50 (470) 0.24 (6) 3.50 (89)
1.26 (32) 1 1/4" (126)
www.hyprofiltration.com
TFR
TFR2 INSTALLATION DRAWING
Length Dimension
Code IN (MM)
(Table 4) A B C D E F G H I J
9.25 (235) 5.24 1 1/2”
8 9.85 (250) 1.97 (50) 5.20 (130) 3.94 (100) 3.54 (90) 0.47 (12) 1.42 (36)
EL removal (136) port
12.0 (305) 5.24 1 1/2”
11 12.6 (320) 1.97 (50) 5.20 (130) 3.94 (100) 3.54 (90) 0.47 (12) 1.42 (36)
EL removal (136) port
18.7 (475) 5.24 1 1/2”
18 20.7 (527) 1.97 (50) 5.20 (130) 3.94 (100) 3.54 (90) 0.47 (12) 1.42 (36)
EL removal (136) port
www.hyprofiltration.com
TFR3 INSTALLATION DRAWING
Length Dimension
Code IN (MM)
(Table 4) A B C D E F G H I J
6.52 2.5”
15 18.5 (469) 2.16 (55) 6.10 (155) 4.50 (114) 4.33 (110) 17.19 (437) 0.55 (14) 2.16 (55)
(165,5) Code 61
6.52 2.5”
19 22.0 (560) 2.16 (55) 6.10 (155) 4.50 (114) 4.33 (110) 20.5 (520) 0.55 (14) 2.16 (55)
(165,5) Code 61
6.52 2.5”
34 37.0 (940) 2.16 (55) 6.10 (155) 4.50 (114) 4.33 (110) 35.5 (901) 0.55 (14) 2.16 (55)
(165,5) Code 61
www.hyprofiltration.com
SUPPLYING PRESSURE TO INDUSTRY
Pressure Sustaining
Power on Demand
ATEX Approval Ex II 2 G D,c T6
Infinitely Variable Flow
Energy Efficient KR & GX PUMPS
Air Driven Pumps and Power Packs
Fluid Pressures from 5 to 680 bar
Quality Engineered
Worldwide Availability www.heypac.com
Company
HEYPAC products have been sold throughout the Principal Operation Page 3
world through our own associate companies and
authorized distributors, who operate in Europe,
North America, Africa, the Middle and Far East GX Range Page 4
and Australia. All associate companies and
distributors have been fully trained and are able
KR Range Page 6
to offer application advice, local product
availability, after sales support and service
facilities. Further details are available on request Sizes and Specifications Page 8
or from the web site at www.heypac.com.
Accessories Page 10
The technical information contained in this catalogue, which does not purport to Ordering Codes Page 16
be comprehensive, has been provided by HEYPAC Limited as a general guide and
should not be used as an alternative to obtaining individual technical advice
specific to the intended application. While this information has been prepared in
good faith, no representation or warranty, express or implied, is or will be made
and no responsibility or liability is or will be accepted by HEYPAC Limited or by any
of their respective officers, employees or agents in relation to the accuracy or
completeness of the technical information contained in this catalogue and any such
liability is expressly disclaimed.
2
Operation
3
Performance
Ratio
2.5:1 5:1 10:1 20:1 30:1 40:1 60:1 80:1
fluid: air
* For definitions of Q Max and Q Max avge see 'Technical Data' section on page 7.
FLUID
PRESS. GX025 AIR
PRESS.
FLUID
PRESS. GX05
AIR
PRESS.
bar (p.s.i) bar (p.s.i) bar (p.s.i) bar (p.s.i)
18 (261) 35 (508)
16 (232)
30 (435)
14 (203)
25 (363)
12 (174)
10 (145) 20 (290)
7 (100)
6 (87)
8 (116) 15 (218)
7 (100)
5 (73)
6 (87) 6 (87) 4 (58)
10 (145)
4 (58) 5 (73) 3 (44)
4 (58) 2 (29)
3 (44) 5 (73)
2 (29) 1.4 (20)
2 (29)
0 0
0 5 10 15 20 25 30 35 40 45 50 55 0 4 8 12 16 20 24 28 32 36 40
(1.3) (2.7) (4) (5.3) (6.7) (8) (9.3) (10.7) (12) (13.3) (14.7) (1.06) (2.12) (3.17) (4.23) (5.29) (6.35) (7.40) (8.47) (9.52) (10.58)
60 (870)
100 (1450)
50 (725)
80 (1160) 7 (100)
40 (580) 7 (100) 6 (87)
6 (87) 60 (870) 5 (73)
5 (73)
30 (435)
4 (58)
4 (58)
40 (580)
20 (290) 3 (44)
3 (44)
2 (29) 20 (290) 2 (29)
10 (145)
1.4 (20) 1.4 (20)
0 0
0 2 4 6 8 10 12 14 16 18 20 0 1 2 3 4 5 6 7 8 9 10
(0.53) (1.06) (1.59) (2.12) (2.64) (3.17) (3.70) (4.23) (4.76) (5.29) (0.26) (0.53) (0.79) (1.06) (1.32) (1.59) (1.85) (2.12) (2.38) (2.64)
180 (2610)
250 (3625)
160 (2320)
140 (2030)
200 (2900)
120 (1740)
4
GX range
FLUID AIR FLUID AIR
PRESS. GX60 PRESS. PRESS. GX80 PRESS.
bar (p.s.i) bar (p.s.i) bar (p.s.i) bar (p.s.i)
400 (5800) 600 (8700)
350 (5075)
500 (7250)
300 (4350)
400 (5800)
250 (3625) 7 (100)
6 (87)
200 (2900) 5 (73) 300 (4350)
7 (100)
4 (58) 6 (87)
150 (2175) 5 (73)
200 (2900)
3 (44) 4 (58)
100 (1450)
100 (1450) 3 (44)
2 (29)
50 (725) 2 (29)
1.4 (20)
1.4 (20)
0 0
0 0.75 1.5 2.25 3 3.75 0 0.5 1 1.5 2 2.5
(0.20) (0.40) (0.60) (0.79) (0.99) (0.13) (0.26) (0.40) (0.53) (0.66)
L/min (US gpm) L/min (US gpm)
Type 'T1'
5
Port threads
GX Range
Fluid Outlet
Fluid Suction Fluid Outlet M Option Alternative Outlet Air Inlet
Model: OO, T1, W1
BSP SAE BSP SAE BSP SAE BSP SAE BSP SAE
GX025 2" NPT 2" NPT G 1" 1" NPT N/A N/A N/A N/A G 3/4" 3/4" NPT
GX05 G 2" 2" NPT G 3/4" 12 SAE N/A N/A N/A N/A G 3/4" 3/4" NPT
GX10 G 1 1/2" 1 1/2" NPT G 3/4" 12 SAE G 3/8" 6 SAE G 1/2" 8 SAE G 3/4" 3/4" NPT
GX20/30/40 G 1" 16 SAE G 1/2" 8 SAE G 3/8" 6 SAE G 1/2" 8 SAE G 3/4" 3/4" NPT
GX60/80 G 1" 16 SAE G 3/8" 6 SAE G 1/4” 4 SAE G 3/8" 6 SAE G 3/4" 3/4" NPT
Fluid Return
Model: R1, R2, R4
BSP SAE
GX05 N/A N/A G 3/4" 12 SAE N/A N/A G 3/4" 12 SAE G 3/4" 3/4"NPT
GX10 N/A N/A G 3/4" 12 SAE N/A N/A G 3/4" 12 SAE G 3/4" 3/4"NPT
GX20/30/40 N/A N/A G 1/2" 8 SAE G 3/8" 6 SAE G 1/2" 8 SAE G 3/4" 3/4"NPT
GX60/80 N/A N/A G 3/8" 6 SAE G 1/4” 4 SAE G 3/8" 6 SAE G 3/4" 3/4"NPT
KR Range
Fluid Outlet Fluid Return
Fluid Suction Fluid Outlet M Option R5 Only Air Inlet
Model: OO, R5, T2, W2 t
BSP SAE BSP SAE BSP SAE BSP SAE BSP SAE
KR02 G 1" 16 SAE G 3/8" 6 SAE N/A N/A G 3/8" 6 SAE G 3/8" 3/8" NPT
KR05 G 1" 16 SAE G 3/8" 6 SAE G 3/8" 6 SAE G 3/8" 6 SAE G 3/8" 3/8" NPT
KR10 G 1" 16 SAE G 3/8" 6 SAE G 3/8" 6 SAE G 3/8" 6 SAE G 3/8" 3/8" NPT
KR20 G 1" 16 SAE G 1/4" 4 SAE G 3/8" 6 SAE G 3/8" 6 SAE G 3/8" 3/8" NPT
KR40 G 1" 16 SAE G 1/4" 4 SAE G 3/8" 6 SAE G 3/8" 6 SAE G 3/8" 3/8" NPT
KR80 G 1" 16 SAE G 1/4" 4 SAE N/A N/A G 3/8" 6 SAE G 3/8" 3/8" NPT
8
Installation
The HEYPAC GX and KR series
pumps are rugged and high
quality products and their long
service life can be increased by
correct installation.
Filtration
Suction strainers (125 or 40 micron
depending on model) are supplied
in all units fitted with a reservoir
but not included with 00, T and W
configuration pumps.
Mounting Orientation
Pumps can be mounted in any orientation with the exception
of all R configuration pumps. The R1, R2 and R5 models must
be mounted vertically with the reservoir beneath the pump
while the R3 and R4 models should be mounted horizontally.
Flow Control
A suitable flow control must be used if the pump is to be
operated at or near maximum flow rate to prevent
overspeeding.
9
Ordering Information
Water option:
W - Pump for use with water (GX05 to 80 only) Design modifications:
Standard GX025 is water compatible DM** (e.g DM27 - Liquid Gas Application Pump)
Other options upon request.
Design modifications:
DM** (e.g DM14 - Low Temperature Seals.)
Other options upon request If you require more information or assistance with
ordering codes please contact your distributor
HEYPAC LIMITED
Unit 3, The Royston Centre, Lynchford Road, Ash Vale, Surrey GU12 5PQ UK
Tel: +44 (0) 1252 511 003 Fax: +44 (0) 1252 519 003
GXKR11/08
Email: enquiries@heypac.com
HEYPAC INCORPORATED
1098 East Avon Road, Rochester Hills, MI 48307 USA
Tel: +1 248 652 3500 Fax: +1 248 652 1717
Email: answers@heypac.com 12
www.heypac.com
Reg'd office: Unit 3 The Royston Centre, Lynchford Road, Ash Vale, Surrey GU12 5PQ United Kingdom. Registered in England number 1386560
Pneumatics
Combo Units, Connectors & Air Filters
modular connectors
Use Speed Clamps™ instead of pipe nipples to Porting Blocks
interconnect components. Provide 3 auxiliary 1⁄4" NPT outlets to pipe C
high-pressure or nonlubricated air. D
modular Pneumatic lockout ValVes B C
3-way function valves can be padlocked in the manifold Blocks
closed (vented) position only. Installed in the Permit 90° attachment of additional system B
pressure inlet of pneumatic devices, safety components such as filters, regulators, or pres-
lockout valves comply with OSHA regulation 29
A
sure switches.
CFR Part 1910 for lockout/tag-out procedures.
Item $ Item $
Key For Use With NPT (in.) No. Each Key For Use With NPT (in.) No. Each
Modular Pneumatic Lockout Valves Speed Mount Pipe Adapters
A Speedaire Compact 1⁄4 4ZM24 36.50 D Compact 1⁄4 4ZK26 16.58
A Speedaire Compact 3⁄8 4ZM25 39.55 D Compact 3⁄8 4ZK27 10.36
A Speedaire Intermediate and Standard 1⁄4 4ZM26 44.40 D Intermediate and Standard 1⁄4 4ZK37 13.89
A Speedaire Intermediate and Standard 3⁄8 4ZM27 42.90 D Intermediate and Standard 3⁄8 4ZK38 13.89
A Speedaire Intermediate and Standard 1⁄2 4ZM28 42.90 D Intermediate and Standard 1⁄2 4ZK39 13.42
A Speedaire Intermediate and Standard 3⁄4 4ZM29 ✓ 55.35 D Intermediate and Standard 3⁄4 4ZK40 13.89
Speed Clamps™ w/Mounting Bracket Porting Blocks (3 NPT Ports)
B Compact — 4ZK25 11.10 — Compact 1⁄4 4ZK28 16.19
B Intermediate and Standard — 4ZK36 14.59 — Intermediate and Standard 1⁄4 4ZK41 19.97
C Compact — 4ZK24 9.34 Manifold Blocks (4 NPT Ports)
C Intermediate and Standard — 4ZK35 10.07 — Compact 3⁄8 4ZK30 44.60
Mounting Brackets — Intermediate and Standard 3⁄4 4ZK43 41.60
C Compact (used with No. 4ZK24) — 4ZK23 4.17
C Intermediate and Standard (used with No. 4ZK35) — 4ZK34 6.07
4033
Pneumatics
Filter/Regulators/Lubricators & Mufflers
mufflers
Length Width Item $
▪ Max. flow: 160 cfm NPT (in.) Fits (in.) (in.) No. Each
▪ Max. pressure: 300 psi Oil Removing Muffler, 0.9 Microns, 160 CFM Max. Flow
1⁄8 1⁄8 3 1⁄8 1 5⁄8 2YNL8 41.60
▪ Max. temp.: 160°F 1⁄4 1⁄4 3 1⁄8 1 5⁄8 2YNL9 46.70
▪ Filter rating: 0.9 microns 3⁄8 3⁄8 4 ⁄4
3 2 7⁄16 2YNN1 58.65
1⁄2 1⁄2 4 3⁄4 2 7⁄16 2YNN2 59.70
▪ Aluminum material
3⁄4 3⁄4 6 1⁄4 3 5⁄16 2YNN3 70.15
▪ 1⁄4" slip-on drain tube fitting 1 1 6 1⁄4 3 5⁄16 2YNN4 70.15
Reclassifier/mufflers help reduce oil mist Replacement Elements
— 1⁄8 and 1⁄4 2 3⁄4 1 5⁄8 2YNN5 39.80
from exhausted air in many in-plant and — 3⁄8 and 1⁄2 4 5⁄16 2 7⁄16 2YNN6 45.40 No. 2YNL8
white room pneumatic applications. — 3 ⁄4 and 1 5 ⁄2
1 3 5⁄16 2YNN7 43.35
4031
Pneumatics
Air Filter Elements & Oil Removal Filters
POLYCARBONATE
Max. POLYCARBONATE W/GUARD METAL W/SIGHT GLASS Item $
NPT Flow H W Item $ Item $ Item $ For Use On Microns No. Each
Description (in.) (cfm)* (in.) (in.) No. Each No. Each No. Each Replacement Oil Removal Coalescing Filter Elements
1⁄8 6 4.25 1.63 4ZL16 61.80 — — — — Miniature 0.01 4ZK21 55.75
Miniature 1⁄4 Compact 0.01 4ZK70 59.45
6.5 4.25 1.63 4ZL17 59.70 — — — —
1⁄4 10.5 7.93 1.97 — — 4ZL24 94.40 4ZL23 101.20 Intermediate 0.01 4ZK56 61.95
Compact 3⁄8 Standard 0.01 4ZK46 60.25
10.5 7.93 1.97 — — 4ZL26 94.40 4ZL25 101.20
1⁄4 21 8.51 2.68 — — 4ZL32 113.85 4ZL31 121.55 Standard (High Flow) 0.01 4ZK47 88.80
Intermediate 3⁄8 21 8.51 2.68 — — 4ZL34 113.85 4ZL33 125.75 Heavy-Duty (3⁄4" to 1") 0.01 4ZK62 167.75
1⁄2 21 8.51 2.68 — — 4ZL36 113.85 4ZL35 121.55 Heavy-Duty (1 1⁄2" to 2") .01 4ZK15 378.50
3⁄8 20 9.31 3.15 — — 4ZL44 139.80 4ZL43 147.60 General Purpose and Oil Removal Filter Mounting Brackets
Standard 1⁄2 35 9.31 3.15 — — 4ZL46 139.80 4ZL45 143.25 Miniature — 4ZK71 11.43
3⁄4 60 11.4 3.15 — — 4ZL55 142.55 — — Compact — 4ZK29 13.26
1⁄2 60 11.4 3.15 — — — — 4ZL53 189.25 Intermediate — 4ZK53 16.57
Standard (High Flow) 3⁄4 Standard — 4ZK42 19.31
60 11.4 3.15 — — — — 4ZL54 189.25
3⁄4 90 13.24 4.75 — — — — 4ZL18 361.00 Heavy-Duty — 4ZK72 56.65
1 125 13.24 4.75 — — — — 4ZL19 361.00 Automatic Filter Drains
Heavy-Duty Miniature — 4ZK17 17.34
1 1⁄2 250 18.86 8.22 — — — — 4ZL20 1,041.00
2 300 18.86 8.22 — — — — 4ZL21 1,064.00 Compact — 4ZK18 36.00
Heavy-Duty with Auto-Drain 2 600 26.71 8.22 — — — — 4ZL22 1,570.00 Intermediate — 4ZK19 43.40
* cfm measured at 100 psig with a saturated element (3 to 5 psig drop). Standard and Heavy-Duty — 4ZK14 48.20
4028
Pneumatics
Hose Couplings and Clamps
universal couplings
▪ Constructed of malleable iron A sexless common head design eliminates mismatched fitting and
▪ Same gasket, safety clip, and allows direct locking connection between any 2 fittings from 1⁄4" to 1".
lanyard for all coupling sizes Nos. 6YZH1 to 6YZH4 do not require a pin; OSHA compliant.
▪ Gasket temp. range: -20° to 160°F Note: Do not use coupling for steam service. Rated for air service only, up to 110 psi.
Blank End (F)NPT End (M)NPT End Hose End (F)NPT SELF LOCKING (M)NPT SELF LOCKING
Size Item $ Item $ Item $ Item $ Item $ Item $ No. 3LX85 No. 6YZH2
(in.) No. Each No. Each No. Each No. Each No. Each No. Each
— 3LX85 11.02 — — — — — — — — — —
1⁄4 — — 3LZ01 9.16 3LX98 10.24 — — — — — — Pkg. Item $
3⁄8 — — 3LX99 8.82 3LX97 7.96 3LZ02 10.30 — — — — Type Qty. No. Each
1⁄2 — — 3LX92 6.85 3LX91 6.78 3LX86 6.73 6YZH1 31.95 6YZH3 32.55 Triple Connection 1 3LX87 18.85
5⁄8 — — — — — — 3LX93 9.59 — — — — Safety Clip 25 3LX83 3.84
3⁄4 — — 3LX96 6.86 3LX95 7.21 3LX94 6.25 6YZH2 32.55 6YZH4 31.95 Nylon Lanyard 25 3LX84 6.29
1 — — 3LX90 8.89 3LX89 8.24 3LX88 8.98 — — — — Rubber Washer 50 3LZ03 20.17
Fittings
Dia. (in.) (in.) No. Each
Ducting Hose Bridge Clamps
4 1⁄2 2TA40 8.26
Constructed of durable steel bar stock. 5 1⁄2 2TA41 8.55
Fittings can be used in steam applications, 6 1⁄2 2TA42 10.10
7 1⁄2 2TA43 9.96
if clamps are used. For use with air, water, 8 1⁄2 2TA44 10.10
fluid petroleum, and chemicals. 9 1⁄2 2TA45 16.50
10 1⁄2 2TA46 16.73
(M)NPT Item $ 12 1⁄2 2TA47 17.19 Quick-Release Clamp
Hose Size (in.) Size (in.) No. Each Quick-Release Clamps No. 2TA48
1⁄4 3LZ76 7.50 4 7⁄8 2TA48 19.23
3⁄8 3LZ77 7.25
1⁄2 6 7⁄8 2TA49 20.78
1⁄2 3LZ70 5.95
No. 8 7⁄8 2TA50 20.80
3⁄4 3LZ75 16.62 10 7⁄8 2TA51 21.16
1⁄2 3LZ73 14.10 3LZ71
12 7⁄8 2TA52 21.84
3⁄4 3⁄4 3LZ74 9.54
1 3LZ72 22.28
1 1 3LZ71 14.16
constant tension
clamps
▪ 5⁄8" band width
▪ 300 stainless steel
steam clamps band/housing/bridge
Allow fittings and couplers ▪ Pkg. qty.: 10
to be used for steam appli- Spring design helps to
cations. Clamps need to be eliminate "cold flow" leakage.
sized up to both I.D. and 0.028"-thick clamps, 125
O.D. of hose. No. in.-lb. of torque. No. 16P218
3LZ04
SCREW MATERIAL
Hose Inside Min. Hose Max. Hose Torque Item $ Plated Carbon Steel 410 Stainless Steel
Dia. (in.) Outside Dia. (in.) Outside Dia. (in.) (ft.-lb.) No. Each Item $ Item $
2 Bolt Max. Clamp Dia. (in.) Min. Clamp Dia. (in.) No. Pkg. No. Pkg.
3⁄8 11⁄16 7⁄8 6 3LZ20 7.88 1 3⁄4 1 16P218 62.80 16P234 68.10
13⁄16 15⁄16 6 3LZ27 7.68 2 1⁄8 1 1⁄4 16P219 63.30 16P235 68.60
15⁄16 1 1⁄16 12 3LZ07 7.68 2 5⁄8 1 3⁄4 16P220 63.55 16P236 69.15
1⁄2
1 1 3⁄16 6 3LX81 6.75 3 1⁄8 2 1⁄4 16P221 64.90 16P237 70.20
1 1⁄16 1 3⁄16 12 3LZ08 8.67 3 5⁄8 2 3⁄4 16P222 65.40 16P238 71.05
1 1⁄8 1 5⁄16 12 3LX82 7.48 4 1⁄8 3 1⁄4 16P223 66.50 16P239 72.10
1 5⁄32 1 9⁄32 21 3LZ12 9.05 4 5⁄8 3 3⁄4 16P224 67.05 16P240 72.60
3⁄4 1 3⁄16 1 5⁄16 21 3LZ11 9.36 5 1⁄8 4 1⁄4 16P225 68.35 16P241 73.95
1 5⁄16 1 1⁄2 21 3LZ09 9.66 5 5⁄8 4 3⁄4 16P226 70.70 16P242 76.35
1 1⁄2 1 11⁄16 21 3LZ04 12.59 6 1⁄8 5 1⁄4 16P227 71.55 16P243 77.15
1 5⁄16 1 1⁄2 12 3LX79 12.59 6 5⁄8 5 3⁄4 16P228 71.80 16P244 77.40
1
1 1⁄2 1 13⁄16 21 3LX80 15.96 7 6 1⁄4 16P229 72.90 16P245 78.70
4 Bolt 7 5⁄8 6 3⁄4 16P230 76.10 16P246 81.90
1 17⁄32 1 23⁄32 21 3LZ10 17.88 8 7 1⁄4 16P231 76.85 16P247 82.70
1 1 11⁄16 1 15⁄16 21 3LZ06 19.74 8 5⁄8 7 3⁄4 16P232 77.65 16P248 83.50
1 11⁄16 2 1⁄8 21 3LZ05 18.52 9 1⁄8 8 1⁄4 16P233 78.70 16P249 84.55
3945
Capacity:
Pilot operated, balanced piston relief valve 12 gpm (45 L/min.)
Product Description
Pilot-operated, balanced-piston relief cartridges are normally closed pressure regulating valves. When the pressure at the
inlet (port 1) reaches the valve setting, the valve starts to open to tank (port 2), throttling flow to regulate the pressure.
These valves are accurate, have low pressure rise vs. flow, they are smooth and quiet, and are moderately fast.
Download
Technical Features
All 2-port relief cartridges (except pilot reliefs) are physically and Back pressure on the tank port (port 2) is directly additive to the valve
functionally interchangeable (same flow path, same cavity for a given setting at a 1:1 ratio.
frame size).
Will accept maximum pressure at port 2; suitable for use in cross port The main stage orifice is protected against contamination.
relief circuits. If used in cross port relief circuits, consider spool leakage.
Minimum setting is 75 psi (5 bar) for all spring ranges. Incorporates the Sun floating style construction to minimize the
possibility of internal parts binding due to excessive installation torque
and/or cavity/cartridge machining variations.
Not suitable for use in load holding applications due to spool leakage.
Technical Data
U.S. Units Metric Units
Cavity T-162A
Capacity 12 gpm 45 L/min.
Factory Pressure Settings Established at 4 gpm 15 L/min.
Maximum Operating Pressure 5000 psi 350 bar
Maximum Valve Leakage at 110 SUS (24 cSt) 2 in³/min.@1000 psi 30 cc/min.@70 bar
Response Time - Typical 10 ms
Series (from Cavity) Series 0
Adjustment - Number of Clockwise Turns to Increase Setting 5
Valve Hex Size 3/4 in. 19,1 mm
Valve Installation Torque 20 - 25 lbf ft 27 - 33 Nm
Adjustment Screw Internal Hex Size 5/32 in. 4 mm
Adjustment Locknut/Cap Hex Size 9/16 in. 15 mm
Adjustment Nut Torque 80 - 90 lbf in. 9 - 10 Nm
Seal Kits - Cartridge Buna: 990-162-007
Seal Kits - Cartridge Viton: 990-162-006
Model Weight 0.22 lb. 0.10 kg.
RPCC-LAN
Material/Coating
Control Adjustment Range Seal Material
Modifier
Preferred Options Preferred Options Preferred Options Preferred Options
L Standard Screw Adjustment A 75 - 3000 psi (5 - 210 bar), N Buna-N No modifier (standard material
Standard Options 1000 psi (70 bar) Standard Standard Options with no special coating)
Setting Special Options
W 75 - 4500 psi (5 - 315 bar),
C* Tamper Resistant - Factory V Viton
1000 psi (70 bar) Standard /AP Stainless Steel, Passivated
Set
Setting
F Hex Head Screw with Locknut Control: C
Standard Options
K Handknob Control: L
B 75 - 1500 psi (5 - 105 bar), Our corrosion resistant product
1000 psi (70 bar) Standard line is growing! If you are
Setting interested in a corrosion
C 75 - 6000 psi (5 - 420 bar), resistant option for this model,
1000 psi (70 bar) Standard please contact Sun.
Setting
N 75 - 800 psi (5 - 55 bar), 400
psi (28 bar) Standard Setting
Q 75 - 400 psi (5 - 28 bar), 200
psi (14 bar) Standard Setting
Product Description
Free-flow, side-to-nose check valves are on/off circuit components that allow free flow from the inlet (port 2) to the outlet (port 1) and
block flow in the opposite direction.
Download
Technical Features
Two-port check valves share the same cavity for a given frame size, Will accept 5000 psi (350 bar) at ports 1 and 2.
however, pay close attention as flow paths may be in opposite
directions.
These check valves are considered circuit savers for existing circuits Only available with 4, 30 and 75 psi (0,3, 2 and 5 bar) cracking
where manifold drillings are incorrect. The capacity of side-to-nose (port pressures.
2 to port 1) 2-port check valves is approximately 30% less than
preferred models with a nose-to-side (port 1 to port 2) flow path.
Check valves offer extremely low leakage rates with a maximum Incorporates the Sun floating style construction to minimize the
leakage of less than 1 drop per minute (0,07 cc/min). possibility of internal parts binding due to excessive installation torque
and/or cavity/cartridge machining variations.
Technical Data
U.S. Units Metric Units
Cavity T-162A
Capacity 7.5 gpm 30 L/min.
Maximum Operating Pressure 5000 psi 350 bar
Maximum Valve Leakage at 110 SUS (24 cSt) 1 drops/min. 0,07 cc/min.
Series (from Cavity) Series 0
Valve Hex Size 3/4 in. 19,1 mm
Valve Installation Torque 20 - 25 lbf ft 27 - 33 Nm
Seal Kits - Cartridge Buna: 990-162-007
Seal Kits - Cartridge Viton: 990-162-006
Model Weight 0.17 lb. 0.08 kg.
CXAD-XCN
Material/Coating
Control Cracking Pressure Seal Material
Modifier
Preferred Options Preferred Options Preferred Options Preferred Options
Technical Data
U.S. Units Metric Units
Cavity T-21A
Capacity 12 gpm 45 L/min.
Check Cracking Pressure 4 psi 0,3 bar
Maximum Operating Pressure 5000 psi 350 bar
Pilot Flow Capacity 46 in³/min. 0,75 L/min.
Pressure Drop, Port 1 to Port 2 100 psi@15 gpm 7 bar@60 L/min.
Series (from Cavity) Series 1
Valve Hex Size 7/8 in. 22,2 mm
Valve Installation Torque 30 - 35 lbf ft 40 - 50 Nm
Adjustment Screw Internal Hex Size 5/32 in. 4 mm
Adjustment Locknut/Cap Hex Size 9/16 in. 15 mm
Adjustment Nut Torque 80 - 90 lbf in. 9 - 10 Nm
Model Weight .35 lb 0,15 kg
Seal Kits - Cartridge Buna: 990-021-007
Seal Kits - Cartridge Viton: 990-021-006
Seal
Control Adjustment Range
Material
Standard Screw 1000 - 3000 psi (70 - 210 bar), 1000 psi (70 bar) Standard
L A N Buna-N
Adjustment Setting
Product Description
Ventable, pilot-operated, balanced piston relief cartridges are normally closed pressure regulating valves. When the
pressure at the inlet (port 1) reaches the valve setting, the valve starts to open to tank (port 2), throttling flow to
regulate the pressure. They provide a vent port (port 3) that connects between the main piston and pilot stage to
provide for remote control by other pilot or 2-way valves. These valves are accurate, have low pressure rise vs. flow,
they are smooth and quiet, and are moderately fast.
Download
Technical Features
A remote pilot relief on port 3 (vent) will control the valve below its own Not suitable for use in load holding applications due to spool leakage.
setting.
Will accept maximum pressure at port 2; suitable for use in cross port Back pressure on the tank port (port 2) is directly additive to the valve
relief circuits. If used in cross port relief circuits, consider spool leakage. setting at a 1:1 ratio.
Main stage orifice is protected by a 150 micron stainless steel screen. Incorporates the Sun floating style construction to minimize the
possibility of internal parts binding due to excessive installation torque
and/or cavity/cartridge machining variations.
Special Notes
For cartridges configured with an O control (panel mount handknob), a .75 in. (19 mm) diameter hole is required in the panel.
Technical Data
U.S. Units Metric Units
Cavity T-11A
Capacity 15 gpm 60 L/min.
Control Pilot Flow 7 - 10 in³/min. 0,11 - 0,16 L/min.
Factory Pressure Settings Established at 4 gpm 15 L/min.
Maximum Operating Pressure 5000 psi 350 bar
Maximum Valve Leakage at 110 SUS (24 cSt) 2 in³/min.@1000 psi 30 cc/min.@70 bar
Response Time - Typical 10 ms
Series (from Cavity) Series 1
Adjustment - Number of Clockwise Turns to Increase Setting 5
Valve Hex Size 7/8 in. 22,2 mm
Valve Installation Torque 30 - 35 lbf ft 40 - 50 Nm
Adjustment Screw Internal Hex Size 5/32 in. 4 mm
Adjustment Locknut/Cap Hex Size 9/16 in. 15 mm
Adjustment Nut Torque 80 - 90 lbf in. 9 - 10 Nm
Seal Kits - Cartridge Buna: 990-011-007
Seal Kits - Cartridge Viton: 990-011-006
Model Weight 0.35 lb. 0.16 kg.
RVCA-LAN
Material/Coating
Control Adjustment Range Seal Material
Modifier
Preferred Options Preferred Options Preferred Options Preferred Options
L Standard Screw Adjustment A 100 - 3000 psi (7 - 210 bar), N Buna-N No modifier (standard material
Standard Options 1000 psi (70 bar) Standard Standard Options with no special coating)
Setting Special Options
W 150 - 4500 psi (10,5 - 315
C* Tamper Resistant - Factory V Viton
bar), 1000 psi (70 bar) /AP Stainless Steel, Passivated
Set
Standard Setting
K Handknob Control: C
Standard Options
O Handknob with Panel Mount Control: L
B 50 - 1500 psi (3,5 - 105 bar), Our corrosion resistant product
1000 psi (70 bar) Standard line is growing! If you are
Setting interested in a corrosion
C 150 - 6000 psi (10,5 - 420 resistant option for this model,
bar), 1000 psi (70 bar) please contact Sun.
Standard Setting
D 25 - 800 psi (1,7 - 55 bar), 400
psi (28 bar) Standard Setting
E 25 - 400 psi (1,7 - 28 bar), 200
psi (14 bar) Standard Setting
If the modifier is /AP, the control must be C or L
Product Description
Free-flow, nose-to-side check valves are on/off circuit components that allow free flow from the inlet (port 1) to the outlet (port 2)
and block flow in the opposite direction.
Download
Technical Features
Check valves offer extremely low leakage rates with a maximum Incorporates the Sun floating style construction to minimize the
leakage of less than 1 drop per minute (0,07 cc/min). possibility of internal parts binding due to excessive installation torque
and/or cavity/cartridge machining variations.
Will accept 5000 psi (350 bar) at ports 1 and 2.
Technical Data
U.S. Units Metric Units
Cavity T-8A
Capacity 5 gpm 20 L/min.
Series (from Cavity) Series P
Valve Hex Size 7/8 in. 22,2 mm
Valve Installation Torque 20 - 25 lbf ft 27 - 33 Nm
Seal Kits - Cartridge Buna: 990-008-007
Seal Kits - Cartridge Viton: 990-008-006
Model Weight 0.11 lb. 0.05 kg.
CXAA-XBN
C
Series 8264 ENCLOSURES
Ordering Information
Empty Aluminum Enclosures with Stainless Steel
cover hinges and mounting rails.
CLASSIFICATIONS
Catalog External Dimensions
NEC & CEC:
Gas Explosion Protection Number LxWxD
Class I, Division 1, Groups B, C & D 8264/6114-3 9.25" x 9.25" x 10.24"; (235 x 235 x 260 mm)
Class I, Zone 1, Groups IIA, IIB & IIB+H2
8264/6214-3 14.17" x 9.25" x 10.24"; (360 x 235 x 260 mm)
Dust Explosion Protection 8264/6224-3 14.17" x 14.17" x 10.24"; (360 x 360 x 260 mm)
Class II, Division 1 Groups E, F & G 8264/6225-3 14.17" x 14.17" x 12.99"; (360 x 360 x 330 mm)
Class III
8264/6325-3 18.90" x 14.17" x 12.99"; (480 x 360 x 330 mm)
Environmental Protection 8264/6335-3 18.90" x 18.90" x 12.99"; (480 x 480 x 330 mm)
Type 3, 4, 4X, 7 & 9 8264/6935-3 28.74" x 18.90" x 12.99"; (730 x 480 x 330 mm)
8264/6995-3 28.74" x 28.74" x 12.99"; (730 x 730 x 330 mm)
FILE No. E307783
Ordering Information
For ATEX and IEC certification please
contact factory.
Empty Stainless Steel Enclosures with Stainless Steel
cover hinges and mounting rails.
Enclosure Materials Catalog External Dimensions
8264/6•••-3 Copper Free Aluminum Number LxWxD
(Marine Grade)
8264/6•••-2 Stainless Steel 316L 8264/6112-2 9.25" x 9.25" x 10.63"; (235 x 235 x 270 mm)
Ambient Temperature 8264/6212-2 14.17" x 9.25" x 10.63"; (360 x 235 x 270 mm)
+50°C (122°F) max. 8264/6222-2 14.17" x 14.17" x 10.63"; (360 x 360 x 270 mm)
-25°C (-13°F) min.
8264/6223-2 14.17" x 14.17" x 13.39"; (360 x 360 x 340 mm)
APPLICATIONS 8264/6323-2 18.90" x 14.17" x 13.39"; (480 x 360 x 340 mm)
The Series 8264 are Explosion Proof and Dust 8264/6333-2 18.90" x 18.90" x 13.39"; (480 x 480 x 340 mm)
Ignition Proof enclosures made of Copper Free 8264/6933-2 28.74" x 18.90" x 13.39"; (730 x 480 x 340 mm)
Aluminum or Stainless Steel 316L. They are
8264/6993-2 28.74" x 28.74" x 13.39"; (730 x 730 x 340 mm)
suitable for use in hazardous (classified) loca-
tions as specified above.
They are designed to contain ordinary location
Mounting Plates
electrical components for Instrumentation, Item Image Description Catalog Number
Motor Control and Distribution. There are eight
sizes of enclosures and they all come with
Optional enclosure 8264/611•-• 82 649 07 55 0
Stainless Steel cover hinges and mounting
Mounting sizes: 8264/621•-• 82 649 08 55 0
rails as standard. Mounting Plates are optional
Plates for 8264/622•-• 82 649 01 55 0
and need to be ordered separately.
Aluminum or 8264/632•-• 82 649 02 55 0
They can be customized with drilled and Stainless Steel 8264/633•-• 82 649 03 55 0
tapped entry openings as well as round and Enclosures 8264/693•-• 82 649 04 55 0
rectangular windows and operators. 8264/699•-• 82 649 05 55 0
Entry and operator openings can be field Fixing Screw Kit 82 648 01 90 6
modified. For details regarding Aluminum
Enclosures see pages I9 and I10. For
Stainless Steel Enclosures see pages I11 Technical Data
and I12.
DESCRIPTION
MAX. INTERRUPTING CAPACITY 10 kA RMS
OF INSTALLED COMPONENTS Symmetrical Amperes
EXTERNAL AUXILIARY DEVICES Listed for Hazardous Locations
(i.e. Push Buttons or Pilot Lights) USL (NOIV) & CNL (NOIV7)
WINDOW MATERIAL Borosilicate Glass
ENCLOSURE MATERIAL Copper Free Aluminum (Marine Grade)
or Stainless Steel 316L
f = Accessories
Code Description
-FS Finger Safe Option
1025 Eagon Street Barberton, Ohio 44203 Ph: 330-745-8891 Fax: 330-745-2504
www.AkronElectric.Com E-Mail: Sales@AkronElectric.Com AKRON 94
S IO N P R Explosion-Proof Pilot Devices
LO
O
Nema Type 4, 4X, 7 & 9
EX
OF
ELE
S
EM
XP 2 & 3 Position Push-Pull Operators
C
T
RI
CAL SY
S Dimensional Data
Dimensions (Inches [mm])
Note: All dimensions are for reference only Base
Ø1.90 [Ø48.3]
Short Barrel
1.60 [40.6] 4.40 [111.7]
2.90 [73.8] 1.49 [37.9]
1.31 [33.4]
LR86146
1.78 [45.2]
CATALOG # XP
X Cap
P (Optional)
& Ø1.48 [Ø37.5]
X
M
Push-Pull Operator
ex. XPPPL-2JR
Operator bodies are black anodized & teflon Explosion-Proof Operators are suitable for panel
impregnated. or surface mount applications.
Operating Shafts are stainless steel. See Contact Block Information sheet for mounting
and rating information.
3/4-14 NPSM threaded body size
Mushroom Push Buttons are 1-1/2 Diameter Aluminum
Long Series: Accommodates up to 2-1/2 thick enclosure
wall thickness. Jumbo 2-1/2 Dia. Aluminum Red Mushroom Button
available
Short Series: Accommodates up to 1 thick
enclosure wall thickness. Push-Pull Operator available 2 or 3 position
1025 Eagon Street Barberton, Ohio 44203 Ph: 330-745-8891 Fax: 330-745-2504
95 AKRON www.AkronElectric.Com E-Mail: Sales@AkronElectric.Com
Explosion-Proof Pilot Devices
Nema Type 4, 4X, 7 & 9
Specifications
XP B S - F G A - FS (-CEN)
a b c d e f g ATEX Optional Extended Pushbutton
XPBS-ERC Flush Pushbutton
a = Push Button Heads XPBS-FGC
f = Contact Blocks
Code Description
B Standard Push Button Head Code Description
MH (red or green button only) **Standard Mushroom Head-Metal Blank No Contacts
JMH (red button only) **Jumbo Mushroom Head-Metal A 1 N.O.
JMHE (white print/red head) **Jumbo Emergency Stop Engraved
B 1 N.C.
2A 2 N.O.
2B 2 N.C.
b = Barrel Type
C 1 N.O. / 1 N.C.
Code Description *D 2 N.O. / 2 N.C.
S Short Barrel E 1 N.C.L.B.
L Long Barrel F 1 N.O.E.M.
2E 2 N.C.L.B.
1025 Eagon Street Barberton, Ohio 44203 Ph: 330-745-8891 Fax: 330-745-2504
www.AkronElectric.Com E-Mail: Sales@AkronElectric.Com AKRON 92
S IO N P R Explosion-Proof Pilot Devices
LO
O
P
Nema Type 4, 4X, 7 & 9
EX
OF
ELE
MS
XP PUSHBUTTON OPERATORS
TE
T
C
RI
CAL S YS DIMENSIONAL DATA
Dimensions (Inches [mm])
Note: All dimensions are for reference only
(Optional)
Extended Pushbutton Extended Pushbutton
ex. XPBS-ER ex. XPBS-FG Extended Pushbutton
ex. XPJMHS-RA Jumbo
X
Guard Base Base Mushroom
P Guard Head
&
X
M Ø1.90 Ø1.90
[Ø48.3] [Ø48.3]
1.78 [45.2] 1.78 [45.2]
1.60 [40.6] 1.60 [40.6]
Features
Operator bodies are black anodized & teflon-impregnated. CLASS I, Div 1 & 2, GROUPS B, C & D;
Operator shafts are stainless steel. CLASS II, Div 1 & 2, GROUPS E, F & G;
3/4-14 NPSM threaded body size. CLASS III;
NEMA TYPE 4, 4X, 7 & 9
Explosion-proof operators are suitable for panel or
surface mount applications
UL 698 Industrial Control Equipment for use in
Long Series: accommodates up to 2-1/2 thick enclosure wall
hazardous (Classified) locations.
thickness
Short Series: accommodates up to 1 thick enclosure wall UL 1203 Explosion-Proof and Dust-Ignition Proof
thickness Electrical Equipment for use in hazardous
Momentary pushbuttons are available in flush and extended (Classified) locations.
versions.
Momentary pushbuttons are molded thermoplastic protected CSA C22.2 No. 30-LR86146 Explosion-Proof
by a machined aluminum guard. Enclosures for use in Class I Hazardous
locations.
1025 Eagon Street Barberton, Ohio 44203 Ph: 330-745-8891 Fax: 330-745-2504
93 AKRON www.AkronElectric.Com E-Mail: Sales@AkronElectric.Com
S IO N P R Explosion-Proof Pilot Devices
LO
O
P
Nema Type 4, 4X, 7 & 9
EX
OF
ELE
MS
Pilot Lights LED
TE
T
C
RI
CAL SYS
Specifications
1025 Eagon Street Barberton, Ohio 44203 Ph: 330-745-8891 Fax: 330-745-2504
87 AKRON
www.AkronElectric.Com E-Mail: Sales@AkronElectric.Com
Explosion-Proof Pilot Devices
Nema Type 4, 4X, 7 & 9
LR86146
(Optional)
XPL Transformer Series is equipped with bayonet Standard sealed construction can be re-lamped from
base receptacles and 12 volt LED lamps the front by removal of the lens guard. (Disconnect
all power prior to performing this procedure).
3/4-14 NPSM threaded body size.
XP Pilot Light Series is equipped with bayonet
Explosion-Proof Pilot Lights are suitable for panel receptacle bases and your choice of 12, 24, 48,
or surface mount applications. 120 or 240 volt LED lamps.
Long Series: Accommodates up to 2-1/2 thick enclosure LED lamps have an operating life upwards of
wall thickness. 100,000 hours @ 25 Deg. C ambient temperature.
Specify voltage desired.
Short Series: Accommodates up to 1-1/2 thick
enclosure wall thickness. Available light bulb colors are Red, White, Blue,
Green and Amber.
Standard 8 flexible leads for connection to
contact blocks. (Consult Factory for custom lengths). See Contact Block Information sheet for mounting
and rating information.
Lens cap guard comes standard with a light gray
powder coat finish.
1025 Eagon Street Barberton, Ohio 44203 Ph: 330-745-8891 Fax: 330-745-2504
www.AkronElectric.Com E-Mail: Sales@AkronElectric.Com AKRON 88
S IO N P R Explosion-Proof Pilot Devices
LO
O
P
Nema Type 4, 4X, 7 & 9
EX
OF
ELE
MS
XP Pilot Light Operators
TE
T
C
RI
CAL SYS Dimensional Data
Dimensions (Inches [mm])
Note: All dimensions are for reference only
Short Barrel
Lens Guard 5.08 [129.0]
3.52 [89.3] 1.56 [39.7]
1.92 [48.8]
Ø1.750
WHT
A/ #12
BLK
600
X
P
&
X 1.38 [34.9]
M
Short Barrel
5.78 [146.8]
Lens Guard 4.22 [107.1] 1.56 [39.7]
1.92 [48.8]
SEC.
Ø1.750
2.97 [75.4]
SEC.
Ø2.38
[Ø60.3]
1.50 [38.1]
1025 Eagon Street Barberton, Ohio 44203 Ph: 330-745-8891 Fax: 330-745-2504
89 AKRON www.AkronElectric.Com E-Mail: Sales@AkronElectric.Com
Data sheet...
Accessories Weidmüller Interface GmbH & Co. KG
Klingenbergstraße 16
EW 35 D-32758 Detmold
Germany
Fon: +49 5231 14-0
Fax: +49 5231 14-292083
www.weidmueller.com
Technical data www.weidmueller.com
Temperatures
Operating temperature Storage temperature
Dimensions
TS 35 offset 22.5 mm
Material data
Material Polyamide 66 Colour Beige
UL 94 flammability rating V-2
System specifications
Product family Accessories Mounting rail TS 35
Classifications
ETIM 2.0 EC001041 ETIM 3.0 EC001041
UNSPSC 30-21-18-01 eClass 4.1 27-08-10-03
eClass 5.1 27-08-10-03 eClass 6.0 27-08-10-03
eClass 7.0 27-08-10-03
Approvals
Approvals
Downloads
DXF 12723_EW_35_DXF.dxf
3-D model
O
P
Nema Type 4, 4X, 7 & 9
EX
OF
ELE
MS
Reset Pushbutton
TE
T
C
RI
CAL SYS
Potentiometer
Dimensions (Inches [mm]) XPPMS-0
XRB (-CEN)
a ATEX Optional FILE NO. E139669 LR86146
(Optional)
a = Barrel Type FILE NO. E181300
Code Description
S Short Barrel CLASS I, Div 1 & 2, GROUPS B, C & D;
L Long Barrel CLASS II, Div 1 & 2, GROUPS E, F & G;
CLASS III,
NEMA TYPE 4, 4X, 7 & 9
Reset Operators
Dimensional Data
Reset
1025 Eagon Street Barberton, Ohio 44203 Ph: 330-745-8891 Fax: 330-745-2504
101 AKRON www.AkronElectric.Com E-Mail: Sales@AkronElectric.Com
https://www.phoenixcontact.com/us/produkte/3210583
Double-level terminal block, Cross section: 0.14 mm² - 4 mm², AWG: 26 - 12, Connection
type: Push-in connection, Width: 5.2 mm, Color: gray, Mounting type: NS 35/7.5, NS 35/15
Product Features
Compact design for maximum space savings
Connect the levels using FBS ...-PV bridges
GTIN
Technical data
General
Number of levels 2
Number of connections 4
Color gray
Insulating material PA
Inflammability class according to UL 94 V0
Dimensions
Width 5.2 mm
Length 68 mm
Height NS 35/7,5 47.5 mm
Height NS 35/15 55 mm
Technical data
Rated surge voltage 6 kV
Pollution degree 3
Surge voltage category III
Insulating material group I
08.02.2013 Page 1 / 4
https://www.phoenixcontact.com/us/produkte/3210583
ASD level 2 2
1.857 (m/s ) /Hz
Acceleration 0.8 g
Test duration per axis 5h
Test directions X-, Y- and Z-axis
Oscillation, broadband noise test result Test passed
Test specification, shock test DIN EN 50155 (VDE 0115-200):2008-03
Shock form Half-sine
Acceleration 5g
Shock duration 30 ms
Number of shocks per direction 3
Test directions X-, Y- and Z-axis (pos. and neg.)
Shock test result Test passed
Temperature index, insulating material (DIN EN 60216-1 (VDE
125 °C
0304-21))
Static insulating material application in cold -60 °C
Connection data
Conductor cross section solid min. 0.14 mm²
Conductor cross section solid max. 4 mm²
Conductor cross section stranded min. 0.14 mm²
Conductor cross section stranded max. 2.5 mm²
Conductor cross section AWG/kcmil min. 26
Conductor cross section AWG/kcmil max 12
Conductor cross section stranded, with ferrule without plastic
0.14 mm²
sleeve min.
Conductor cross section stranded, with ferrule without plastic
2.5 mm²
sleeve max.
Conductor cross section stranded, with ferrule with plastic sleeve
0.14 mm²
min.
Conductor cross section stranded, with ferrule with plastic sleeve
2.5 mm²
max.
2 conductors with same cross section, stranded, TWIN ferrules
0.5 mm²
with plastic sleeve, max.
Connection method Push-in connection
Stripping length 10 mm
Internal cylindrical gage A3
Classifications
ETIM
UNSPSC
UNSPSC 11 39121410
UNSPSC 12.01 39121410
UNSPSC 13.2 39121410
UNSPSC 6.01 30211811
UNSPSC 7.0901 39121410
eCl@ss
08.02.2013 Page 4 / 4
https://www.phoenixcontact.com/us/produkte/3210596
Protective conductor double-level terminal block, Cross section: 0.14 mm² - 4 mm², AWG: 26 - 12,
Connection type: Push-in connection, Width: 5.2 mm, Color: green-yellow, Mounting type: NS
35/7.5, NS 35/15
Product Features
Same shape and pitch as the feed-through terminal blocks
Contact is made free from mechanical and electrical errors by simply snapping onto the DIN rail
All the requirements of standard IEC 60947-7-2 are met
GTIN
Technical data
General
Number of levels 2
Number of connections 4
Color green-yellow
Insulating material PA
Inflammability class according to UL 94 V0
Dimensions
Width 5.2 mm
Length 68 mm
Height NS 35/7,5 47.5 mm
Height NS 35/15 55 mm
Technical data
Rated surge voltage 6 kV
08.02.2013 Page 1 / 3
https://www.phoenixcontact.com/us/produkte/3210596
ASD level 2 2
1.857 (m/s ) /Hz
Acceleration 0.8 g
Test duration per axis 5h
Test directions X-, Y- and Z-axis
Oscillation, broadband noise test result Test passed
Test specification, shock test DIN EN 50155 (VDE 0115-200):2008-03
Shock form Half-sine
Acceleration 5g
Shock duration 30 ms
Number of shocks per direction 3
Test directions X-, Y- and Z-axis (pos. and neg.)
Shock test result Test passed
Temperature index, insulating material (DIN EN 60216-1 (VDE
130 °C
0304-21))
Static insulating material application in cold -60 °C
Connection data
Conductor cross section solid min. 0.14 mm²
Conductor cross section solid max. 4 mm²
Conductor cross section stranded min. 0.14 mm²
Conductor cross section stranded max. 2.5 mm²
Conductor cross section AWG/kcmil min. 26
Conductor cross section AWG/kcmil max 12
Conductor cross section stranded, with ferrule without plastic
0.14 mm²
sleeve min.
Conductor cross section stranded, with ferrule without plastic
2.5 mm²
sleeve max.
Conductor cross section stranded, with ferrule with plastic sleeve
0.14 mm²
min.
Conductor cross section stranded, with ferrule with plastic sleeve
2.5 mm²
max.
08.02.2013 Page 2 / 3
https://www.phoenixcontact.com/us/produkte/3210596
Classifications
ETIM
UNSPSC
UNSPSC 11 39121410
UNSPSC 12.01 39121410
UNSPSC 13.2 39121410
UNSPSC 6.01 30211811
UNSPSC 7.0901 39121410
eCl@ss
08.02.2013 Page 3 / 3
Edison Fuses – Fuse Holders Company
Information
Systems
Part number guide for CH series fuse holders: M = Midget class; CC = CC class;
Features 1D, 2D, 3D = 1, 2, and 3 pole configurations; I = with NEON indicator; -1 = quantity of 1.
Overview
• IEC 60947-3
Gearbox
CHM: Edison MCL, MOL, MEQ, MEN midget fuses. • IEC 60947-3
CHCC: Edison HCLR, HCTR, EDCC fuses • CE Compliant • CE Compliant
Steppers/
Servos
Conductor
No. of 17.5mm
Proximity
Configuration
Wire Range
Max
Series Voltage Holder Box Pkg. Fuse Holder Pkg.
Wt. Price with NEON Box Wt. Price degrees C, Max.
Modules*
&
Size Current Without Qty. (lbs.) Indication Qty. (lbs.) Cu Wire Photo
cURus
Torque
cULus
Phase
Sensors
Indication Only) /
IEC
Number of Limit
CHM1D-1 1 0.14 <---> CHM1DI-1 1 0.14 <---> Conductors Switches
• † • 1 pole 1
UL/CSA 600 CHM1D 12 1.8 <---> CHM1DI 12 1.8 <---> 0.8 - 4 mm² Solid, Stranded 2.3 Nm Encoders
CHM VAC/DC, (18 - 12 AWG) / Single (20 lb-in)
30A (3 Watt) CHM2D-1 1 0.3 <---> CHM2DI-1 1 0.3 <--->
Midget • † • 2 pole 2 Current
Sensors
Class IEC 690 VAC, CHM2D 6 1.8 <---> CHM2DI 6 1.8 <---> 5.0 mm²
Solid / Single
32A (10 AWG)
CHM3D-1 1 0.4 <---> CHM3DI-1 1 0.4 <---> Pressure
• † • 3 pole 3 Sensors
CHM3D 4 1.8 <---> CHM3DI 4 1.8 <---> 5.0 - 8.0 mm² Stranded /
CHCC1D-1 1 0.14 <---> CHCC1DI-1 1 0.14 <---> (10 - 8 AWG) Single Temperature
†† • 1 pole 1 2.8 Nm Sensors
CHCC1D 12 1.8 <---> CHCC1DI 12 1.8 <---> (25 lb-in)
CHCC UL/CSA 0.8 - 2.0 mm²
CHCC2D-1 1 0.3 <---> CHCC2DI-1 1 0.3 <---> Solid / Dual Pushbuttons/
Class 600VAC/DC, †† • 2 pole 2 (18 - 14 AWG) Lights
CC 30A CHCC2D 6 1.8 <---> CHCC2DI 6 1.8 <--->
CHCC3D-1 1 0.4 <---> CHCC3DI-1 1 0.4 <---> 0.8 - 5.0 mm² Process
†† • 3 pole 3 Stranded / Dual
(18 - 10 AWG)
CHCC3D 4 1.8 <---> CHCC3DI 4 1.8 <---> Relays/
Timers
*Holder width as compared to standard 17.5 mm module (1 = 17.5 mm, 2 = 35 mm, 3 = 52.5 mm) † cUL Recognized (SCCR:
10 kA †† cUL Listed (SCCR: 200 kA)
Comm.
Note: To add additional poles, see multi-pole connection kit JV-L in Accessories. Retired accessories AL-D and CH810-HP will
not work with new design.
Terminal
Blocks &
Wiring
Fuse Holders Dimensions DIN Rail Removal
Power
Enclosures
Tools
Pneumatics
Safety
Appendix
2 Rotate out.
Product
Index
Part #
Index
Volume 14
Cooper Bussmann
Homepage KTK-R-1-1/2
About Cooper Bussmann Fast Acting, Class CC Fuse
Contact Us
Privacy
Legal
Cooper Bussmann® Brand
Site Map
Product Information
Product Type: Fuse
Product Family: Electrical Power
Upgrade Product: LP-CC-1-1/2 Certifications
Brand: Cooper Bussmann UL Listed
Sub-brand: Limitron CSA Certified
Class: CC
Electrical Properties
Recommended Products Maximum AC
600
Rec. Fuse Block: BC603 Series Voltage:
Physical Properties
1.5in.(L) × 0.41in.(W) × 0in.
Dimensions:
(H)
Bussmann®
LIMITRON® KTK-R
Fast-Acting Fuses
13/32” x 1-1/2”, Class CC - 600 Volt, 1/10 - 30 Amps
Dimensional Data • LIMITRON® fast-acting fuse.
• Melamine tube. Nickel-plated brass endcaps.
• U.L. Listed for branch circuit protection.
• Rejection type; for both standard holders or those which
1.59
reject other type fuses.
(±0.031)
(38.1mm) Time-Current Characteristic Curves–Average Melt
.419
(±0.005)
(10.3mm)
Cooper Bussmann
Homepage KTK-R-2-1/2
About Cooper Bussmann Fast Acting, Class CC Fuse
Contact Us
Privacy
Legal
Cooper Bussmann® Brand
Site Map
Product Information
Product Type: Fuse
Product Family: Electrical Power
Upgrade Product: LP-CC-2-1/2 Certifications
Brand: Cooper Bussmann UL Listed
Sub-brand: Limitron CSA Certified
Class: CC
Electrical Properties
Recommended Products Maximum AC
600
Rec. Fuse Block: BC603 Series Voltage:
Physical Properties
1.5in.(L) × 0.41in.(W) × 0in.
Dimensions:
(H)
Bussmann®
LIMITRON® KTK-R
Fast-Acting Fuses
13/32” x 1-1/2”, Class CC - 600 Volt, 1/10 - 30 Amps
Dimensional Data • LIMITRON® fast-acting fuse.
• Melamine tube. Nickel-plated brass endcaps.
• U.L. Listed for branch circuit protection.
• Rejection type; for both standard holders or those which
1.59
reject other type fuses.
(±0.031)
(38.1mm) Time-Current Characteristic Curves–Average Melt
.419
(±0.005)
(10.3mm)
Cooper Bussmann
Homepage KTK-R-4
About Cooper Bussmann Fast Acting, Class CC Fuse
Contact Us
Privacy
Legal
Cooper Bussmann® Brand
Site Map
Product Information
Product Type: Fuse
Product Family: Electrical Power
Upgrade Product: LP-CC-4 Certifications
Brand: Cooper Bussmann UL Listed
Sub-brand: Limitron CSA Certified
Class: CC
Electrical Properties
Recommended Products Maximum AC
600
Rec. Fuse Block: BC603 Series Voltage:
Physical Properties
1.5in.(L) × 0.41in.(W) × 0in.
Dimensions:
(H)
.419
(±0.005)
(10.3mm)
The HPS ImperatorTM series of machine tool rated industrial control transformers are specifcally
designed to meet high inrush industrial applications where electromagnetic components such as
relays, solenoids and magnetic motor starters are used.
With 11 standard voltage groups, a VA range from 50VA to 5000VA and available with standard
secondary and optional primary fuse kits, the HPS ImperatorTM series provides the perfect solution
for any application.
The HPS Imperator's unique terminal block design (patent pending) allows for the quick and easy
installation of standard secondary or optional primary13/32" x 1 1/2" midget/type CC fuse clips on
every unit. This is the simplest and most inexpensive fusing installation provided on any industrial
control transformer in the market today.
Key features:
• Optional primary fuse kits available utilizing 13/32” x 1 1/2” midget/type CC fuse
clips (available on all standard units up to and including 1500VA)
• Optional finger safe terminal covers available on all units up to and including
1500VA
• UL Listed (approved for U.S. and Canada)
• CE Mark standard on all molded units up to and including 1500VA
(excluding PH***AJ & PH***AR)
• LIFETIME Warranty (Limited)
• RoHS Compliant
1
special voltages and VA sizes available upon request
2
excluding PH750PG, PH1000PG, PH750MLI, PH1000MLI
Warranty
Lifetime
34
© Hammond Power Solutions Inc. Data subject to change without notice.
SECTION
SECTION 1
9 HPS IMPERATORTM
SECTION 1
Terminal connection numbers molded into the
terminal block and correspond to the nameplate
and wiring diagrams which makes
connecting the HPS Imperator
quick and simple. Standard secondary and optional
primary fuse kits utilizing 13/32” x 1 1/2”
midget/type CC fuse clips provide an
economical solution to your fusing
requirements (fuses not available).
35
© Hammond Power Solutions Inc. Data subject to change without notice.
SECTION 1 HPS IMPERATORTM
C
SECTION 1
C
GxH GxH
D E
D E A B
A
B
FIGURE A
FIGURE C
C
GxH
D E
A FIGURE B
Group C
Primary Voltage: 240 x 480 230 x 460 220 x 440
Secondary Voltage: 120 x 240 115 x 230 110 x 220 50/60 Hertz
Overall Mounting Mounting Height Depth Approx. Optional
VA Catalog Mtg. Output Dimensions Centers Slot with with Ship Primary
Rating Number Fig. Amps Finger Finger Weight Fuse
A B C D E GXH Guard Guard Lbs. Kit P/N
50 PH50MQMJ A 0.42/0.21 3.00 4.38 3.19 2.50 2.25 0.22 x 0.44 4.00 5.82 3.50 PFK1
75 PH75MQMJ A 0.63/0.31 3.25 3.88 3.56 2.63 2.50 0.22 x 0.44 4.37 5.32 3.54 PFK1
100 PH100MQMJ A 0.83/0.42 3.25 4.19 3.63 2.63 2.63 0.22 x 0.44 4.44 5.63 4.50 PFK1
150 PH150MQMJ B 1.25/0.63 4.00 4.94 3.81 3.38 2.75 0.22 x 0.75 4.50 6.44 5.70 PFK2
250 PH250MQMJ B 2.08/1.04 4.50 5.44 3.81 3.75 3.13 0.22 x 0.75 4.50 6.94 7.50 PFK2
350 PH350MQMJ B 2.92/1.46 4.50 5.19 4.44 3.75 3.75 0.22 x 0.75 4.94 6.69 10.1 PFK3
500 PH500MQMJ B 4.17/2.08 4.75 5.94 4.31 4.06 3.81 0.31 x 0.94 4.81 7.44 14.2 PFK3
750 PH750MQMJ B 6.25/3.13 5.13 6.69 4.31 4.38 4.31 0.31 x 0.81 4.81 8.19 16.6 PFK3
1000 PH1000MQMJ B 8.33/4.17 5.25 6.81 4.94 4.50 4.44 0.31 x 0.81 5.56 8.31 23.6 PFK3
1500 PH1500MQMJ B 12.5/6.25 5.25 8.19 4.94 4.50 6.06 0.38 x 1.00 5.56 9.69 32.0 PFK3
2000 PH2000MQMJ C 16.7/8.33 6.38 7.50 5.50 4.38/5.31 6.00 0.31 x 1.13 N/A N/A 45.4 N/A
3000 PH3000MQMJ C 25.0/12.5 7.50 10.00 6.25 4.50/6.00 7.00 0.38 x 1.00 N/A N/A 76.7 N/A
5000 PH5000MQMJ C 41.7/20.8 9.00 11.00 7.63 5.25/7.00 7.00 0.44 x 1.00 N/A N/A 121.2 N/A
Secondary fuse clips, fuse clip mounting screws and primary and secondary voltage links/jumpers supplied standard with transformers up to All dimensions in inches
and including 1500VA. Refer to page 54 for wiring schematic drawing. Special voltages and VA sizes available upon request.
Units over 1500VA are UL approved and CSA certified, but do not carry the CE mark.
*** Available with FACTORY INSTALLED Primary and Secondary Fuse Kits up to 1500VA. To order,add the suffix “-FK” to the abover part number. Refer to page 49 for details. ***
38
© Hammond Power Solutions Inc.
SECTION 1 HPS IMPERATORTM
HPS IMPERATOR6HULHV:LULQJ6FKHPDWLF'UDZLQJVFRQWLQXHG
Group C
220V HV 440V 3+
040-6FKHPDWLFIRUDQG9$8QLWV
SECTION 1
230V 460V
240V 480V High Voltage (HV) Install Supplied Links Supply Lines Install Fuse
1 2 3 4 1 2 3 4 (Primary Volts) Between Terminals Connect To Clips To
Low Voltage (LV) Install Supplied Links Load Lines Install Fuse
4 3 2 65 1
(Secondary Volts) Between Terminals Connect To Clips To
120 115 110 3-4, 1-2 1, 4 Unfused
4 3 2 1 4 3 2 1 240 230 220 2-3 1, 4 Unfused
110V 220V 120 115 110 3-4, 1-2 4, 6 1-5
115V 230V 240 230 220 2-3 4, 6 1-5
120V LV 240V
Low Voltage (LV) Install Supplied Links Load Lines Install Fuse
5 4 3 17 2 (Secondary Volts) Between Terminals Connect To Clips To
6 5 4 3 2 1 6 5 4 3 2 1 120 115 110 4-5, 2-3 2, 5 Unfused
240 230 220 3-4 2, 5 Unfused
110V 220V
115V 230V 120 115 110 4-5, 2-3 1, 5 2-7
120V LV 240V 240 230 220 3-4 1, 5 2-7
© Hammond Power Solutions Inc. Data subject to change without notice.
SECTION 1
6(&7,21 HPS IMPERATORTM
Fuse Kits
SECTION 1
secondary fuse kits which include: 13/32” x 1 1/2” midget/type CC fuse clips, fuse clip mounting
screws, primary and secondary voltage links and the PHAK1 instruction sheet (note: secondary fuse clips and
fuse clip mounting screws are not supplied on the PH750PG, PH1000PG, PH750MLI, and PH1000MLI).
Sample Assembly Drawing for Sample Assembly Drawing Sample Assembly Drawing
Voltage Link Installation for Secondary Fuse Clip for Primary Fuse Clip
IRU9$WR9$ Installation Installation
IRU9$WR9$ IRU9$WR9$
Note: HPS Imperator primary and secondary fuse kits are not suitable for branch circuit applications!
© Hammond Power Solutions Inc. Data subject to change without notice.
Machine Tool Control Transformers and Accessories 11
INTERCONNECT
Overall Dimensions Mounting Centers Mtg. Slot Optional
Stock Mfr.’s VA Mtg. Output (Inches) (Inches) (Inches) EACH Primary
No. Type Rating Fig. Amps Fuse Kit
A B C D E G×H Stock No.
70191755 PH50MLI 50 A 0.43/2.08 3.25 4.06 3.56 2.63 2.50 0.22 × 0.44 43.96 70191785
70191756 PH75MLI 75 A 0.65/3.13 3.25 4.25 3.56 2.63 2.50 0.22 × 0.44 48.25 70191786
70191757 PH100MLI 100 A 0.87/4.17 3.25 4.69 3.63 2.63 2.63 0.22 × 0.44 54.45 70191786
70191758 PH150MLI 150 B 1.30/6.25 4.00 5.44 3.81 3.38 2.75 0.22 × 0.75 70.73 70191787
70191759 PH250MLI 250 B 2.17/10.42 4.50 5.19 4.44 3.75 3.75 0.22 × 0.75 93.90 70191787
70191760 PH350MLI 350 B 3.04/14.58 4.50 5.56 4.44 3.75 3.75 0.22 × 0.75 109.03 70191788
ENCLOSURES
70191761 PH500MLI 500 B 4.35/20.83 4.75 6.69 4.31 4.06 4.50 0.31 × 0.94 129.94 70191788
70191762 PH750MLI 750 C 6.52/31.25 5.25 6.50 4.94 4.50 4.13 0.31 × 0.81 176.26 70191788
70191763 PH1000MLI 1000 C 8.70/41.67 5.25 8.19 4.94 4.50 5.81 0.31 × 0.81 204.37 70191788
240/480, 230/460, 220/440 Primary Voltage, 12/24, 11.5/23, 11/22 Secondary Voltage — Secondary Fuse Clips Included But Not Installed
Primary Voltage 240 × 480 230 × 460 220 × 440
Secondary Voltage 12 × 24 11.5 × 23 11 × 22
TRANSFORMERS
Stock Mfr.’s VA Mtg. Output (Inches) (Inches) (Inches) EACH Primary
No. Type Rating Fig. Amps Fuse Kit
A B C D E G×H Stock No.
70191729 PH50QR 50 A 4.17/2.08 3.00 4.38 3.19 2.50 2.25 0.22 × 0.44 43.96 70191782
70191730 PH75QR 75 A 6.25/3.13 3.25 3.88 3.56 2.63 2.50 0.22 × 0.44 48.25 70191782
70191731 PH100QR 100 A 8.33/4.17 3.25 4.19 3.63 2.63 2.63 0.22 × 0.44 54.45 70191782
70191732 PH150QR 150 B 12.5/6.25 4.00 4.94 3.81 3.38 2.75 0.22 × 0.75 70.73 70191783
70191733 PH250QR 250 B 20.8/10.4 4.50 5.44 3.81 3.75 3.13 0.22 × 0.75 93.90 70191783
70191734 PH350QR 350 B 29.2/14.6 4.50 5.19 4.44 3.75 3.75 0.22 × 0.75 109.03 70191784
70191735 PH500QR 500 B 41.7/20.8 4.75 5.94 4.31 4.06 3.81 0.31 × 0.94 129.94 70191784
AUTOMATION &
380/277/208 Primary Voltage, 120/240 Secondary Voltage — Secondary Fuse
CONTROL
Clips Included But Not Installed
Primary Voltage 380/277/208
Secondary Voltage 120 × 240
OPTOELECTRONICS
70191773 PH50MGJ 50 A 0.42/0.21 3.25 3.88 3.56 2.63 2.50 0.22 × 0.44 43.96 70191785
70191774 PH75MGJ 75 A 0.63/0.31 3.25 4.19 3.63 2.63 2.63 0.22 × 0.44 48.25 70191786
70191775 PH100MGJ 100 A 0.83/0.42 3.25 4.69 3.63 2.63 2.63 0.22 × 0.44 54.45 70191786
70191776 PH150MGJ 150 B 1.25/0.63 4.00 5.44 3.81 3.38 2.75 0.22 × 0.75 67.24 70191787
70191777 PH250MGJ 250 B 2.08/1.04 4.50 4.88 4.44 3.75 3.75 0.22 × 0.75 89.26 70191787
70191778 PH350MGJ 350 B 2.92/1.46 4.50 5.56 4.44 3.75 3.75 0.22 × 0.75 109.03 70191788
70191779 PH500MGJ 500 B 4.17/2.08 4.75 6.69 4.31 4.06 4.50 0.31 × 0.94 136.71 70191788
70191780 PH750MGJ 750 B 6.25/3.13 5.25 6.81 4.94 4.50 4.44 0.31 × 0.81 185.51 70191788
70191781 PH1000MGJ 1000 B 8.33/4.17 5.25 7.25 4.94 4.50 4.83 0.31 × 0.81 204.37 70191788
70191793 FG5 MBMH, MEMX, MGJ, MLI, PG 750 1 Finger guard 2.71 Stock Mfr.’s Used Applicable
All 1000, 1500 Description EACH
No. Type With VA Sizes
70191794 FGF1 AJ, AR, MQMJ, MEMX, QR, SP, PG, PP 50 1 Finger guard (fused) 2.16 70191789 FG1 AJ, AR, MQMJ, MEMX, QR, SP, PG, PP 50 1 Finger guard (unfused) 1.83
70191795 FGF2 MBMH, MGJ, MLI 50 1 Finger guard (fused) 2.16 70191790 FG2 MBMH, MGJ, MLI 50 1 Finger guard (unfused) 1.83
All 75 All 75
All Except PH100MBMH 100 All — EXCEPT PH100MBMH 100
11
TRANSFORMERS 1017
www.weg.net
Controls
Standard IEC Contactors
CWM / CWME
SERIES
J AC/DC coils with electronic modules available from 100HP and up J Kneading and mixing machines
J Elevator
Certifications
Conformity to Standards
J UL508 Approvalas
J CSA C22.2 No 14 J cULus Listed
J IEC60947-1; IEC60947-4-1 J CE marked
J Bureau Veritas
Certifications
Controls
Standard IEC Contactors - CWM & CWME Series
Catalog part number composition
CWM / CWME
SERIES
CONTROLS
STANDARD IEC CONTACTORS - CWM & CWME Series
CWM 18 - 10 - 30 V18
STANDARD CONTACTOR SERIES:
Data is subject to change without notice. WEG Automation - Products and Solutions B-31
www.weg.net
Controls
IEC Contactors - CWM Series
3 pole contactors with AC coil
CWM / CWME
SERIES
Maximum UL Horsepower
Auxiliary Contacts
Single Phase Three Phase Catalog Number List Price Multiplier Symbol
115V 230V 200V 230V 460V 575V N.O. N.C.
1 0 CWM9-10-30*
1/2 1 1/2 3 3 5 7 1/2 $72 Z1
0 1 CWM9-01-30*
1 0 CWM12-10-30*
3/4 2 3 3 7 1/2 10 $89 Z1
0 1 CWM12-01-30*
1 0 CWM18-10-30*
1 3 5 5 10 15 $103 Z1
0 1 CWM18-01-30*
0 0 CWM25-00-30* $118 Z1
2 5 7 1/2 7 1/2 15 15
1 1 CWM25-11-30* $138 Z1
0 0 CWM32-00-30* $140 Z1
3 5 10 10 20 25
1 1 CWM32-11-30* $160 Z1
0 0 CWM40-00-30* $164 Z1
3 5 10 15 30 25
1 1 CWM40-11-30* $184 Z1
0 0 CWM50-00-30* $190 Z1
3 7 1/2 15 15 40 40
1 1 CWM50-11-30* $210 Z1
0 0 CWM65-00-30* $215 Z1
5 10 20 20 50 50
1 1 CWM65-11-30* $235 Z1
0 0 CWM80-00-30* $261 Z1
7 1/2 15 20 25 50 60
1 1 CWM80-11-30* $281 Z1
0 0 CWM95-00-30* $294 Z1
7 1/2 15 25 30 60 75
1 1 CWM95-11-30* $314 Z1
0 0 CWM105-00-30* $393 Z1
10 20 30 40 75 75
1 1 CWM105-11-30* $413 Z1
Controls
IEC Contactors - CWM Series
CWM / CWME
SERIES
3 pole contactors with DC coil
Maximum UL Horsepower
Auxiliary Contacts
Single Phase Three Phase Catalog Number List Price Multiplier Symbol
115V 230V 200V 230V 460V 575V N.O. N.C.
1 0 CWM9-10-30+
1/2 1 1/2 3 3 5 7 1/2 $93 Z1
0 1 CWM9-01-30+
1 0 CWM12-10-30+
3/4 2 3 3 7 1/2 10 $111 Z1
0 1 CWM12-01-30+
1 0 CWM18-10-30+
1 3 5 5 10 15 $125 Z1
0 1 CWM18-01-30+
2 5 7 1/2 7 1/2 15 15 0 0 CWM25-00-30+ $141 Z1
3 5 10 10 20 25 0 0 CWM32-00-30+ $180 Z1
3 5 10 15 30 25 0 0 CWM40-00-30+ $230 Z1
3 7 1/2 15 15 40 40 0 0 CWM50-00-30+ $255 Z1
5 10 20 20 50 50 0 0 CWM65-00-30+ $280 Z1
7 1/2 15 20 25 50 60 0 0 CWM80-00-30+ $335 Z1
7 1/2 15 25 30 60 75 0 0 CWM95-00-30+ $360 Z1
10 20 30 40 75 75 0 0 CWM105-00-30+ $470 Z1
Data is subject to change without notice. WEG Automation - Products and Solutions B-33
www.weg.net
Controls
Thermal Overload Relays - RW Series
Three-pole Thermal Overload Relay Class 10
JAdjustable tripping current
J Phase-loss sensitivity
J Tripping class 10
J Hand/Auto/Reset button
RW SERIES
ACW
Molded-Case Circuit Breaker
UL 489 Listed
USA ACW
www.weg.net
Overview
Introducing the WEG ACW Series of Molded Case Circuit Breakers now
available with UL489 certification. Available in four different compact
frames, the New ACW Series will assure top performance for both thermal
and short-circuit protection from 15 to 800Amps.
Current ratings
Trip units
Trip type
Applicable to ACW125, 250, 400, and 800 frames
t
Ratings (A) @ 40 Co FTU
Fixed thermal
Number of poles
15…800A rated current
Fixed magnetic
400…8000A trip current
Short-circuit trip
current, Im
0 Ir Im
Trip type
Overload current
setpoint, Ir
Trip type
Overload current
setpoint, Ir
Note: WEG is committed to maintain stock for immediate delivery of the following trip units:
FTU – ACW125P and ACW125W
FMU – ACW250P, ACW250W, ACW400P, ACW400W, ACW800P, ACW800W
Please contact your WEG representative office for availability of other trip units.
Selection guide
A C W 1 2 5 P - F T U 8 0 - 3
kA rating @ Code
Frame Code 460VAC Number of Code
poles
125 ACW125 35 P
3 3
250 ACW250 65 W
400 ACW400
800 ACW800
Note: Wiring terminal (lugs) not included. Lugs are available as accessory at page 12.
ACW250P - FMU trip unit – Adjustable thermal and fixed magnetic
Note: Wiring terminal (lugs) not included. Lugs are available as accessory at page 12.
Note: WEG is committed to maintain stock for immediate delivery of the following trip units:
FTU – ACW125P and ACW125W
FMU – ACW250P, ACW250W, ACW400P, ACW400W, ACW800P, ACW800W
Please contact your WEG representative offce for availability of other trip units.