Storage Capacity 200 GB SSD, 2x 1 TB HDDs 400 GB SSD, 4x 1 TB HDDs 2x 400 GB SSD, 4x 1 TB HDDs 2x 800 GB SSD, 4x 1 TB HDDs 2x 400 GB SSD, 4x 1 TB HDDs 2x 800 GB SSD, 4x 1 TB HDDs
Memory Configurable; 32 GB or 64 GB Configurable; 64 GB or 128 GB Configurable; 128 GB or 256 GB Configurable; 128 GB, 256 GB or 512 GB
VM Density Up to 15 Virtual Machines* Up to 50 Virtual Machines* Up to 100 Virtual Machines* Up to 115 Virtual Machines*
Certifications CSAus, FCC, CSA, ICES, CE, KCC, C-TICK VCCI-A, BSMI, EAC, SABS, INMETRO, S-MARK, UKRSEPRO** CSAus, FCC, CSA, ICES, CE, KCC, C-TICK VCCI-A, BSMI, EAC, SABS, INMETRO, S-MARK, UKRSEPRO**
Appliance Specifications
Height: 3.5’’ (88mm), Width: 17.25’’ (438mm),
Dimensions Depth:26.75’’ (679mm) Height: 3.5’’ (88mm), Width: 17.25’’ (438mm), Depth:26.75’’ (679mm)
66.45 lbs. (30.1kg) stand-alone / 90.15 lbs. 67.2 lbs. (30.5kg) stand-alone / 77.2 lbs.
Weight (35kg) package / 7 lbs (3.2kg) node* 67.2 lbs. (30.5kg) stand-alone / 77.2 lbs. (35kg) package / 7 lbs (3.2kg) node*
(40.9kg) package / 5.25 lbs (2.4kg) node*
System Cooling 4x80mm heavy duty fans with PWM fan speed controls 4x80mm heavy duty fans with PWM fan speed controls
Power Consumption 470W maximum, 350W typical 1150W maximum, 1000W typical 1350W maximum, 1100W typical
* Package weight includes rails and all accessories, standalone weight includes all drives ©2014 Nutanix, Inc. All Rights Reserved
Virtual Computing Platform Specifications
VM Density Up to 75 Virtual Machines* Up to 100 Virtual Machines* Up to 115 Virtual Machines* Up to 110 Virtual Machines* Up to 115 Virtual Machines*
Users - GRID K1 vSGA: 8-64, Up to 3500 mailboxes,
GRID K2 vSGA: 6-48, GRID K2 vDGA: 6 * 100 messages per day
Network 2x 10 GbE, 2x 1 GbE, 1x 10/100 BASE-T RJ45 2x 10 GbE, 2x 1 GbE, 2x 10 GbE or 4x 10 GbE
Connections 1x 10/100 BASE-T RJ45 4x 1 GbE, 1x 10/100 BASE-T RJ45
CSAus, FCC, CSA, ICES, CE, KCC, C-TICK VCCI-A, CSAus, FCC, CSA, ICES, CE, KCC, C-TICK VCCI-A,
Certifications CSAus, FCC, CSA, ICES, CE, KCC, C-TICK VCCI-A, BSMI, EAC, SABS, INMETRO, S-MARK, UKRSEPRO** BSMI, EAC, SABS, INMETRO, S-MARK, UKRSEPRO ** BSMI, EAC, SABS, INMETRO, S-MARK, UKRSEPRO **
* VM density dependent on use case, ** For more information, email regulatory_compliance@nutanix.com 3x PCIe expansion slots;
GPU/PCoIP Up to 2x GRID K1, 3x GRID K2, 1x APEX
System Cooling 4x80mm heavy duty fans with PWM fan speed controls 5x80mm heavy duty fans with 3x80mm heavy duty fans with
PWM fan speed controls PWM fan speed controls
Op Temp Rng: 50°-95°F (10°-35°C) Op Temp Rng: 50°-95°F (10°-35°C) Op Temp Rng: 50°-95°F (10°-35°C)
Operating Non-Op Temp Rng: -40°-158°F (-40°- 70°C) Non-Op Temp Rng: -40°-158°F (-40°- 70°C) Non-Op Temp Rng: -40°-150°F (-40°- 70°C)
Op Humidity Rng (non-condensing): 8-90% Op Humidity Rng (non-condensing): 8-90% Op Humidity Rng (non-condensing): 8-90%
Environment Non-Op Humidity Rng: 5-95% Non-Op Humidity Rng: 5-95%
Non-Op Humidity Rng: 5-95%
700W maximum,
Power Consumption 900W maximum, 700W typical 1100W maximum, 900W typical 1200W maximum, 900W typical 700W maximum, 525W typical
550W typical
Power Supply 1.1kW Out @100-120V, 12.0-10.0A, 50-60HZ; 1.0kW Out @100-120V, 12.0-10.0A, 50-60HZ;
920W Out @100-240V, 11.0-4.4A, 50-60HZ
(Dual supply/block) 1.62kW Out @180-240V, 10.5-8.0A, 50-60Hz 1.8kW Out @200-240V, 10.0- 8.5A, 50-60Hz
Thermal Dissipation 2400 BTU/hr maximum 3070 BTU/hr maximum, 2400 BTU/hr typical 3750 BTU/hr maximum, 3070 BTU/hr typical 4090 BTU/hr maximum, 1875 BTU/hr maximum,
1700 BTU/hr typical 3070 BTU/hr typical 2475 BTU/hr typical
Operating Input Voltage: 100-240V AC auto-range Input Voltage: 100-240V AC auto-range
Input Voltage: 180-240V AC auto-range, Input Frequency: 50-60Hz Input Frequency: 50-60Hz Input Frequency: 50-60Hz
Requirements
* Package weight includes rails and all accessories, standalone weight includes all drives SS/SpecSheet/8814 ©2014 Nutanix, Inc. All Rights Reserved