This document contains important information about the SoMove Lite software.
Please read the complete document before you start the installation and
operation of the product.
Schneider Electric assumes no responsibility for any errors that may appear in this document. If you have any suggestions for
improvements or amendments or have found errors in this publication, please notify us. No part of this document may be reproduced in
any form or by any means, electronic or mechanical, including photocopying, without express written permission of Schneider Electric. All
pertinent state, regional, and local safety regulations must be observed when installing and using this product. For reasons of safety and
to help ensure compliance with documented system data, only the manufacturer should perform repairs to components. When devices
are used for applications with technical safety requirements, the relevant instructions must be followed. Failure to use Schneider Electric
software or approved software with our hardware products may result in injury, harm, or improper operating results. Failure to observe this
information can result in injury or equipment damage.
© 2010 Schneider Electric. All rights reserved.
1 SoMove Lite V1.2.2.0
SoMove is user-friendly setup software for PCs, for setting up of Schneider Electric motor
control devices. SoMove software incorporates various functions for the device setup phases,
such as Configuration preparation, Start-up and Maintenance.
1.1 Registration
The Product must be registered with in 4 days of first use, if not the application will stop
working after this period. You must register to continue to use the product.
2 System Requirements
2.4 Pre-requisites
.NET Framework 3.5 SP1 must be installed, before installing SoMove. This is downloadable
from the Microsoft website at below link
http://download.microsoft.com/download/2/0/e/20e90413-712f-438c-988e-fdaa79a8ac3d/
dotnetfx35.exe
3 Installation
In order to install SoMove Lite software, you must have administrative privileges to install and
uninstall programs.
Note: Admin privileges are not required to run SoMove Lite once installed.
You can re-run the installer from the Add/Remove Programs Control Panel.
If you have already installed SoMove Lite, the installer gives you options to Modify, Repair or
Remove SoMove Lite.
Note: To Modify or Repair SoMove installer should be available.
4 Restrictions
5 AltivarDtmLibrary
5.1 Overview
5.4 Information
Dtms
Functions ATV31-3
ATV12 ATV32
12
Connection, Load from device, Store to device
actions are prohibited when ARE<>No in the
connected device. This parameter is reserved to X
transfer ATV31 configurations with a loader or
keypad.
ATV312, 600V references are removed for
V5.1IEXX in SoMove V1.2, users having V5.1
X
600V devices will have to manage with SoMove
V1.1 only
5.5 Restrictions
Dtms
Functions ATV31-
ATV12 ATV32
312
No contextual help X X X
Function block - ATV Logic Monitoring and X
Import/Export functions are not available with the
current version
Dtms
Functions ATV31-
ATV12 ATV32
312
Several Help button exists in dialog boxes but X X X
have no action
Store to device is not permitted when the PLC program X
is running in the connected device, a popup error
indicates «Store to device is not possible».
Command panel sometimes cannot be made X
inactive when the ADC parameter in automatic
DC injection is changed to continuous and
executed a Run and stop.
Command panel is allowing to run the motor in X
reverse when RRS parameters is assigned to
NO.
Factory Settings not possible sometimes or the X
progress bar goes into infinite loop due to
connection lost
Command Panel: Drive status is not updated X
even after resetting the EPF1 (External fault on
Li3). Updates only on restarting the application
Random exception thrown when assigning multi X
configuration through drive.
MyMenu sometimes does not get updated in the X
drive after setting it through the application.
After the connection lost, drive still shows online X
for long time and command panel also is in
active state
Export to PDF file: Some parameters are missing X
in the pdf file. e.g.:-EN 19 to EN 35, OIR and
TAFI.
Several Help button exists in dialog boxes but X X X
have no action
Save project file is not prompted after X
modification of parameters after opening a saved
project file.
5.7 Troubleshoot
1. Load from Device - If a load from device action is interrupted by a device power OFF, then the
subsequent load from device actions will fail.
Resolution:
* Power ON the device and try Load from device again, or if problem persists still then
* Restart SoMove and try Load from device again
2. Functional Block - In ATVLogic configuration dialog box, an error message warns “Date is
integer”.
Resolution:
* The date must be entered in the required format: 8 digits: MMDDYYYY
3. Functional Block - If you want copy / paste a whole program from the PRE to the AUX for
example, we have the following behavior:
> Only blocks are pasted (no Inputs/outputs and no links will be pasted).
> The past operation will not paste all blocks copied from the PRE section. It depends on the
position of the last click in the window.
> Create link on 'paste blocks' is not always possible. In this case, it is necessary to delete
blocks and create new one.
6 AltistartDtmLibrary
6.1 Overview
6.3 Restrictions
Dtms
Functions
ATS22
No contextual help X
Dtms
Functions
ATS22
Several Help button exists in dialog boxes but have no action X
6.5 Troubleshoot
1. Load from Device - If a load from device action is interrupted by a device power OFF, then the
subsequent load from device actions will fail.
Resolution:
* Power ON the device and try Load from device again, or if problem persists still then
* Restart SoMove and try Load from device again
7 ModbusDtmLibrary
This document gives recommendations and provides additional information for installing and running the
Communication DTM for Modbus Serial
Communication DTM for Modbus TCP
Note: During the installation of the Modbus Communication Library also the Schneider PC Driver for
Modbus Serial Line will be installed on the system.
7.2 Directories
By default, Modbus Communication DTM Library Configuration Software will be installed in the directory.
-<CommonProgramFiles>
-Schneider Electric Shared
- Modbus Communication DTM Library
- Modbus Serial Line CommDTM
- Modbus TCP CommDTM
8.1 Overview
8.3. Information
8.4. Restrictions
Effected Dtms
Function LXM32 LXM32
LXM32C
A M
No contextual help X X X
Supported Languages DE, EN, FR, IT, ES X X X
Supported Languages IO Module – English &
n/a n/a X
German only
LXM32M: Safety Assistant not fully
n/a n/a X
implemented
LXM32M: Scaling Wizard not implemented n/a n/a X
Effected Dtms
Function
LXM32 LXM32
LXM32C
A M
Several Help button exists in dialog boxes but
X X X
have no action
Scope: Register Parameters can not be used
X X X
as Trigger
Scope: Trigger Level does not accept values X X X
with fractional digits although the initial value
can show fractional digits. Use raw UINT32
values instead.