CTE Results For ACCR Core
CTE Results For ACCR Core
CTE Results For ACCR Core
Test 1
Test 2
2
Test 3
Test 4
3
Test 5
Test 6
4
Test 7
Test 8
5
Comparison CTE curves of ACCR obtained from Tests 3-8 under the temperature range (20 -300)C
6
Mean of the CTE curves of ACCR obtained from Tests 3-8 under the temperature range (20 -300)C
7
Calculations for mean and standard dieviation for CTE of ACCR core
8
∆L 13.7∗10−6 −6
α 1= = =5.826∗10 /° C
L ∆ T 10.1∗10−3∗232.8
∆L 13∗10−6 −6
α 2= = =5.652∗10 / °C
L ∆ T 10.1∗10 ∗227.7
−3
∆L 16.52∗10−6 −6
α 3= = =5.837∗10 /° C
L ∆T 10.1∗10−3∗280.5
∆L 16.72∗10−6 −6
α 4= = =5.923∗10 /° C
L ∆ T 10.1∗10−3∗279.2
∆L 17.78∗10−6 −6
α 5= = =6.293∗10 /° C
L ∆ T 10.1∗10 ∗279.8
−3
∆L 15.81∗10−6 −6
α 6= = =5.534∗10 /° C
L ∆ T 10.1∗10−3∗283
∆L 16.4∗10−6 −6
α 7= = =5.756∗10 /° C
L ∆T 10.1∗10−3∗282
∆L 17.58∗10−6 −6
α 8= = =6.243∗10 /° C
L ∆ T 10.1∗10 ∗279
−3
Mean CTE from the average CTE calculations (Room temp -300 ⁰C):
Standard deviation –
σ=
√ ∑ (α i−α mean)2
i=1
Where, N = 6
N
=2.663∗10−7 /° C