Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Direct & Inverted Pendulum

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Direct & Inverted Pendulum

Pendulum

EASY MONITORING
LONG-TERM RELIABILITY
ACCURACY GREATER THAN WITH GEODESIC SURVEYS

Pendulums are designed to accurately measure the relative internal horizontal displacements
of points along a true vertical line

Description Key Features

Direct pendulum  High accuracy and resolution


The direct pendulum consists of a wire suspended from the upper  Long-term reliability
point and a reading station fixed to the structure at the lower point.  Accuracy greater than with geodesic surveys
The wire is tensioned by a suspended weight submerged in a  Regular monitoring without frequent costly surveys
damper tank.
 Telependulum for remote readings and automatic data
Inverted pendulum acquisition
The fixed end of the inverted pendulum is grouted at the lower point
of the system. A float tensions the wire vertically. When anchored to
a fixed point in the foundation, it measures absolute displacement of Applications
points along the wire.
 Monitoring of movements within dams, dam founda-
The monitoring of the wire position for both direct and inverted pen- tions, nuclear power stations, viaducts and bridge
dulums can be done manually and/or electrically with a remote
piers
readout unit (ref: Model RxTx Telependulum – see separate bro-
 Monitoring of structural and foundation movements in
chure). The method of reading depends upon the concept of moni-
toring, the expected values of movements, and the accuracy re- buildings
quired.  Reference for surveying monitoring method

www.roctest.com 
Direct & Inverted Pendulum
Pendulum

Specifications
PENDULUM COMPONENTS 
   Direct pendulum  Stainless steel or invar wire 
Upper hook and vee‐shaped guide bracket 
Wire tensioning weight and hook 
Damper tank 
   Inverted pendulum  Wire (same as for direct pendulum) 
Anchoring weight 

MODEL 76  
   Range  ±15 mm 
   Resolu on  0.1 mm 
   Accuracy  0.5 mm 
   Reading sta on component  Stainless steel table 
(includes scales, cursors, sights and chart for evalua ng wire posi on) 
MODEL MVR  
   Range  400 mm 
   Accuracy  0.02 mm 
   Focal range  ±50 mm 
   Overall dimensions  500 x 500 mm 

Manual Reading Options and Interpretations

A) Sighting reading table Model 76


To take a reading, the operator aligns the cursors with their respective
sights and with the pendulum wire. The positions of the cursors are
read directly off the scale and the vernier cursor. The readings are
converted to wire displacement values using the chart provided with
each reading station.

B) Optical coordinoscope Model MVR


The setup consists of a reference base permanently installed at the
reading point. The coordinoscope is then installed on its reference
section respectively at X and Y axes on the base frame. Measurements
are taken by focusing or aiming the lens at the pendulum wire and by
reading the current lateral displacement on the vernier. Reading Table Model 76

Ordering Information
Please specify:
• Type of pendulum
• Wire length
• Manual or remote reading station

Optional Accessories
• Mounting brackets
• Creep test kit for long term testing at constant pressure

Roctest Ltd, 
680 Birch  Street 
St‐Lambert, Quebec  Phone  +1 450 465 1113  Email  info@roctest.com 
Canada J4P 2N3  Fax.      +1 450 465 1938  Web    www.roctest.com 
Doc: E50091‐160131  Roctest reserves the right to make any changes in the specifica ons without prior no ce 
 