Sika® Bentoshield® Max LM: Product Data Sheet
Sika® Bentoshield® Max LM: Product Data Sheet
Sika® Bentoshield® Max LM: Product Data Sheet
1/5
storage and disposal sites”
▪ EN 13361:2004 - Geosynthetic barriers “Characterist-
ics required for use as a fluid barrier in the construc-
tion of reservoirs and dams”
▪ EN 13362:2006 - Geosynthetic barriers “Characterist-
ics required for use in the construction of Canals
▪ BBA Certificate 16/5342 for waterproofing structures
PRODUCT INFORMATION
Chemical Base Polymer modified natural sodium bentonite and polypropylene geotextiles
Packaging 1.1m x 5m rolls
2.5m x 25m rolls (available on request)
(tolerance ±3%)
Appearance / Colour Black woven / White non-woven geotextiles, yellow polyethylene laminate
Shelf Life 2 years from date of production
Storage Conditions Store properly in dry conditions in undamaged and unopened original
sealed packaging.
Effective Thickness Thickness 6,5mm (EN 964-1)
PE Thickness 0.3mm (ASTM D 5199)
SYSTEM INFORMATION
System Structure ▪ Sika® BentoShield® Max LM is installed with the woven geotextile in con-
tact with the concrete surface to be waterproofed.
▪ No priming is required as the system mechanically bonds to poured con-
crete thus forming an integral seal which prevents water migration.
▪ By lapping joints with a minimum overlap of 100 mm between adjoining
edges and 100 mm between roll ends a continuous waterproof barrier is
created. Laps should be staggered by 300 mm to avoid a build up of
product in one location.
▪ All vertical lap joints are sealed with Sika BentoShield SS50 Bonding Tape.
Horizontal lap joints can be sealed with Sika BentoShield SS50 Bonding
Tape, a 5 mm x 50 mm fillet of Sika BentoShield Granules or a similar fil-
let of Sika BentoShield Paste, and closed with staples or fixing system.
2/5
▪ The concrete slab should be steel re-enforced and of
Important: Always conduct trials before combining a minimum thickness of 150 mm.
products in specific mixes and contact the Sika Tech-
nical Service Department for information and advice
about any specific combinations.
3/5
▪ Protrusions through the membrane, such as piles, user of the product must test the product’s suitability
service pipes, conductors & anchors, should be for the intended application and purpose. Sika re-
sealed by forming a hole through the membrane, fit- serves the right to change the properties of its
ting the membrane securely over the protrusion, products. The proprietary rights of third parties must
bedding the membrane onto the protrusion be observed. All orders are accepted subject to our
▪ using SikaBentoShield Paste or a paste created by current terms of sale and delivery. Users must always
mixing SikaBentoShield Granules with water. refer to the most recent issue of the local Product Data
Sheet for the product concerned, copies of which will
be supplied on request.
FURTHER DOCUMENTS
Index Flux < 5,0 x 10-9 (ASTM D 5887)
m3/sec-m2
Free Swell > 27 ml/2g (ASTM D 5890)
Fluid Loss < 15 ml (ASTM D 5891)
Montmorillonite <80% (XRD Analysis)
Content
Non Woven - 200 g/sq.m (ASTM D 5261)
Mass/Unit Area
(ASTM D
Woven - 110 g/sq.m
5261)
Mass/Unit Area
Density Nominal 5.00
kg/m2
pH Value 9.5 +/- 0.5
VALUE BASE
All technical data stated in this Product Data Sheet are
based on laboratory tests. Actual measured data may
vary due to circumstances beyond our control.
LOCAL RESTRICTIONS
Please note that as a result of specific local regula-
tions the performance of this product may vary from
country to country. Please consult the local Product
Data Sheet for the exact description of the application
fields.
LEGAL NOTES
The information, and, in particular, the recommenda-
tions relating to the application and end-use of Sika
products, are given in good faith based on Sika’s cur-
rent knowledge and experience of the products when
properly stored, handled and applied under normal
conditions in accordance with Sika’s recommenda-
tions. In practice, the differences in materials, sub-
strates and actual site conditions are such that no war-
ranty in respect of merchantability or of fitness for a
particular purpose, nor any liability arising out of any
legal relationship whatsoever, can be inferred either
from this information, or from any written recom-
mendations, or from any other advice offered. The