5991-1059EN LC - Supplycatalogo
5991-1059EN LC - Supplycatalogo
5991-1059EN LC - Supplycatalogo
Buy online:
www.agilent.com/chem/store
Contact us:
www.agilent.com/chem/contactus
LC AND LC/MS
5991-1059EN
LC AND LC/MS The Essential Chromatography and Spectroscopy Catalog is now available
in a boxed set to help you easily find the products and information you need.
Each catalog is your essential resource for:
• Product photos and ordering information • Troubleshooting tips
Maximize system performance • Selection guides and applications • Maintenance schedules
and produce quality results time after time • Compatibility charts
Agilent HPLC columns and supplies are designed, tested, and manufactured with the same attention to detail you expect from Agilent instruments.
That means your LC or LC/MS system will deliver superior qualitative and quantitative results, consistent reproducibility and reliability, and ultra
high-sensitivity detection.
Your boxed set includes comprehensive information for Agilent's
entire portfolio of Chromatography and Spectroscopy columns
and supplies in the following catalogs:
LC and LC/MS, including CE and CE/MS – Maximize system performance and produce
quality results time after time with LC capillaries, lamps, and the entire family of ZORBAX LC columns
for small molecules, biomolecules and GPC/SEC.
The ZORBAX LC column family Spectroscopy – Satisfy your growing demand to screen large numbers of samples, faster, with supplies
and standards for Atomic Absorption, ICP-OES, ICP-MS, MP-AES and Molecular Spectroscopy.
From research… to leading-edge method development… to routine quality assurance… Agilent ZORBAX
and Poroshell HPLC columns are optimized for high throughput analysis, and feature the sensitivity,
For more information and to request additional catalogs,
accuracy, and reliability that demanding applications require. Other advantages include:
please visit www.agilent.com/chem/catalog
• A wide selection of chemistries, including Eclipse Plus, Eclipse XDB, StableBond, Extend, Bonus-RP,
HILIC and more
• Superior flexibility and scalability with a wide range of particle sizes (1.8, 3.5, 5, and 7 µm) and
column dimensions
Special Offers from Agilent
• Individual column performance reports that document column-to-column and lot-to-lot reproducibility
You don't have to look far to find valuable offers that feature high-performance
• Superior particle strength, even with demanding high-pressure applications columns and supplies, accessories, and more.
Just go to www.agilent.com/chem/specialoffers to find out about our latest offers.
And be sure to check back often, because we'll update this page throughout the year!
For more details about these offers, contact your local Agilent office or Authorized Agilent Distributor.
Table of Contents
Agilent Solutions, Services and Support .......................2 Columns for Small Molecule Separations ..................... 204
Featured Products .............................................................6 HPLC Column Selection....................................................206
Agilent Parts and Supplies Fast Columns for Reversed-Phase HPLC/UHPLC........227
General LC Supplies ..........................................................11 Columns for Reversed-Phase Analytical HPLC ............247
LC Capillaries......................................................................16 Columns for Preparative HPLC ........................................311
Fittings and Unions............................................................22 Columns for Other HPLC Techniques.............................323
Pump Supplies....................................................................47 Agilent Specialty Particles ...............................................347
Autosampler Supplies.......................................................61 Appendices .........................................................................343
Fraction Collector Supplies ..............................................68 Columns for Biomolecules ............................................... 350
Valve Supplies ....................................................................72 Biocolumn Selection Guidelines .....................................354
Thermostatted Column Compartment Suppplies.........82 Biomolecule Separations .................................................353
Detector Supplies ..............................................................89 UHPLC/HPLC Techniques ................................................364
Bio-inert Quaternary LC Supplies ...................................101 Method Development........................................................444
LC/MS Supplies.................................................................103 Capillary and Nano Columns ...........................................452
Agilent CrossLab LC Parts and Supplies........................112 MicroBore Columns ..........................................................461
Product Introductions .......................................................112 Purification – Prep HPLC..................................................464
Supplies for Waters HPLC Systems ...............................137 Appendices .........................................................................477
Supplies for Shimadzu HPLC Systems...........................150 Columns and Standards for GPC/SEC............................ 488
Supplies for Dionex HPLC Systems................................157 GPC/SEC Columns ............................................................490
Supplies for CTC Analytics HPLC Autosamplers .........169 Polymer Standards ............................................................530
CE and CE/MS...................................................................170 Applications ....................................................................... 552
Solution Kits........................................................................170 BioPharmaceutical ............................................................552
Capillaries............................................................................178 Chemical/Industrial...........................................................580
Instrument Parts and Supplies........................................191 Environmental.....................................................................583
Troubleshooting..................................................................201 Food and Consumer Products .........................................594
Pharmaceutical ..................................................................611
Indices ................................................................................ 644
Ordering Information ........................................................ 667
www.AGILEnt.COM/ChEM/LC 1
Agilent Solutions
Put MOrE thAn 40 yEArS OF rELEntLESS InnOvAtIOn
BEhInd yOur EvEry rESuLt
By continually raising the standards for technologies that support your routine analyses, Agilent's R&D efforts have led to breakthroughs such as:
• new GC columns that help you achieve higher levels of inertness and column-to-column reproducibility
• LC column choices that deliver the sensitivity and reliability you need for demanding applications
• Cutting-edge sample preparation products that promote reliable extraction and concentration
• Fresh atomic and molecular spectroscopy ideas for identifying and confirming targets and unknowns
Longtime Agilent customers have experienced our commitment firsthand. And now, we look forward to demonstrating
how Agilent's approach to relentless innovation can work to your advantage, too.
C H E M I C A L A N A LY S I S S O L U T I O N S
Food Forensics
From high-volume screening of vegetables for large numbers of Because the careers of world class athletes and many other
pesticides to rapid identification of pathogens, Agilent understands individuals hinge on drug testing, it’s critical that those doing
the analytical needs of food producers, shippers, and regulators. the testing have the highest level of confidence in the results.
When a new toxin appears, we deploy substantial resources to Forensics analysts worldwide have grown to depend on
quickly help customers develop robust and reliable methods. Agilent tools for accuracy, reliability, and speed in this high
Agilent's leading separations, mass spectrometry, and spectroscopy stakes, high-throughput field. Our best selling GC, GC/MS
solutions are emerging as valuable food testing techniques. and popular LC and LC/MS are workhorses in forensics labs.
2
LIFE SCIENCE SOLUTIONS
Biopharmaceutical
Genomics
As “multi-omics” studies gain momentum in the search
for new therapeutics, Agilent is uniquely positioned Agilent is a global leader in microarrays, scanners, and reagents used
to provide the instruments, reagents, and powerful in a wide variety of genomic-based disease research experiments.
software needed for performing experiments in multiple Our SureSelect Target Enrichment System dominates the category,
disciplines and combining the massive amounts of data streamlining next generation sequencing studies worldwide. Agilent
into biological insight. offers a wide range of catalog microarrays and a highly-developed
capability to produce custom arrays featuring ink jet-based SurePrint
fabrication and the eArray on-line design tool. All Agilent microarrays
feature highly sensitive, selective 60-mer probes. With as many as eight
arrays printed on a standard 1 x 3 in slide, the cost per experiment
Pharmaceutical becomes very affordable.
www.AGILEnt.COM/ChEM/LC 3
AGILEnt SErvICE And SuPPOrt
4
AGILEnt SErvICE And SuPPOrt
www.AGILEnt.COM/ChEM/LC 5
FEAturEd PrOduCtS
6
FEAturEd PrOduCtS
Low-flow LC Solutions
with unmatched Performance and Stability
Low-flow LC separation with high sensitivity detection and low sample consumption is a well-established and
proven technology. The low-flow technique is used frequently for applications where limited amounts of sample
are available, for analysis of trace level components in complex mixtures, or when an optimized LC/MS
combination is required. The Agilent 1260 Infinity Low-flow LC systems offer unsurpassed low-flow
performance and stability.
www.AGILEnt.COM/ChEM/LC 7
FEAturEd PrOduCtS
8
FEAturEd PrOduCtS
www.AGILEnt.COM/ChEM/LC 9
FEAturEd PrOduCtS
Agilent LC Capillaries
Agilent LC capillary starter kits contain the most often used capillaries and fittings. Our genuine flexible
stainless steel capillaries make the best connection in your LC system, no matter the brand. The kits are for
use with 3-4 or 1-2 mm id columns, as well as for Micro LC columns. The free Cybertool, which contains
over 30 tools, is useful in every laboratory.
turn to page 16.
10
AGILEnt PArtS And SuPPLIES
General LC Supplies
Agilent offers a wide range of supplies for operation and maintenance of LC systems. These products have
been carefully designed or selected by Agilent to work with your Agilent instruments for maximum
performance and uptime.
Hex keys, Rheotool 5064-8211
LC Tools
Your Agilent LC system arrives with a full complement of tools needed to perform general maintenance
and operation procedures. Should you need additional or replacement tools, Agilent offers a selection Mounting tool, 0100-1710
of high-precision, high-quality, stainless steel tools, to avoid any deformation of the screws or nuts.
LC tools
description Part no.
Tool kit hex keys, Rheotool 5064-8211
Includes 3 hex keys, 4 mm, 1.5 mm, and 9/64 in, with straight or T-handle plus Rheotool
Torque wrench adapter G1315-45003
Used with nanoliter flow cell for Diode Array Detector to mount capillaries of cell
(P/N G1315-68714)
Insert tool (seal wash option) 01018-23702 HPLC system tool kit, G4203-68708
Mounting tool for flangeless nut 0100-1710
Mounting clamp 5021-1866
Velocity regulator 5062-2486
USB memory stick G4208-68700
Compact flash card 01100-68700
HPLC system tool kit G4203-68708
Compact tool kit G4296-68715
Torque wrench, 2-25 Nm G4220-20012
Bit kit for torque wrench 5023-0282
Compact tool kit, G4296-68715
PEEK Luer lok needle assembly 5190-0924
Plastic tubing cutter 8710-1930
Blades for plastic cutter, 5/pk 8710-1931
Tubing clip 5042-9967 Torque wrench, 2-25 Nm, G4220-20012
Tubing clip 5042-9954
Open end wrench, 14 mm 8710-1924
www.AGILEnt.COM/ChEM/LC 11
AGILEnt PArtS And SuPPLIES
RRLC in-line filter, 5067-1551 Low dispersion in-line filter, 01090-68702 Semi-prep filter, 5064-8273
High pressure semi-prep filter, 5022-2165 1290 Infinity LC in-line filter, 5067-4638
12
AGILEnt PArtS And SuPPLIES
Solvent Filters/Degassers
An added benefit of filtering solvents is that degassing occurs at the same time. This is particularly beneficial
if you do not have an on-line degasser in your system. The benefits of solvent filtration:
Solvent Filters/degassers
description Part no.
HPLC solvent filter/degasser assembly 3150-0577
replacement Parts for 3150-0577
Glass funnel, 250 mL 5188-2743
PTFE coated sieve 5188-2744
PTFE seal 5188-2745 Glass solvent filter degasser, 3150-0577
Funnel base, glass 5188-2746
Filter Membranes
Regenerated cellulose filter membranes 3150-0576
Diameter 47 mm, pore size 0.45 µm, 100/pk
Nylon filter membranes 9301-0895
Diameter 47 mm, pore size 0.45 µm, 100/pk
PTFE filter membranes 3150-0509
Diameter 47 mm, pore size 0.45 µm, 10/pk
www.AGILEnt.COM/ChEM/LC 13
AGILEnt PArtS And SuPPLIES
height 99 cm
width 48 cm
depth 43 cm
weight 27 kg
The Agilent rack can be used to optimize your 1290 Infinity LC for ultra-low dispersion, which can enhance performance of high-efficiency
columns. Further information can be found in application note 5990-9502EN at www.agilent.com/chem/library
14
AGILEnt PArtS And SuPPLIES
LC Standards
LC Standards
description Part no.
Caffeine standards kit for LC OQ/PV 8500-6762
Includes one 10 mL ampoule: 125.0 µg/mL; four 5 mL ampoules: 5.0, 25.0, 250.0
and 500.0 µg/mL caffeine in water
Caffeine standards kit for capillary OQ/PV 5065-4420
Includes 5 ampoules, 5 mL: 2.0, 4.0, 20.0, 100.0, 200.0 µg/mL caffeine in water
Caffeine OQ/PV sample for dissolution test, 150 mg/L caffeine in water, 500 mL 5042-6476
Caffeine OQ/PV sample for dissolution test,
Caffeine standard, 250 µg/mL G4218-85000
5042-6476
Enterprise Edition caffeine standard kit 5190-0488
Fluorescence detector calibration sample, 1 g glycogen 5063-6597
RI detector OQ/PV test sample 5064-8220
Includes 5 ampoules, 5 mL: 5, 10, 15, 25, and 50 mg/mL glycerin in water
Isocratic and gradient standards 01080-68702
Contains 0.15% diethylphthalate, 0.01% biphenyl, and 0.03% terphenyl in MeOH (w/w).
Gradient standard includes 0.32% dioctyl phthalate as well. Two 0.5 mL ampoules of each.
Isocratic standard, 0.5 mL ampoule 01080-68704
RRLC Check out sample, 1 mL ampoule 5188-6529
Chip cube high mass reference (HP-1221), 0.5 mL G1982-85001
Chip cube high mass solvent (FC-70), 25 mL Fluorinert G1982-85002
Chip cube low mass reference sample, 1 g Methyl stearate G1982-85003
ESI+APCI LC demo sample G1978-85000
Contains 5 x 1 mL ampoules with 33 ng/µL crystal violet,
77 ng/µL carbazole, 300 ng/µL 9-phenanthrol, 1 ng/µL 1-hexanesulfonic acid sodium salt
in water/methanol 60:40
ES-TOF biopolymer reference standard kit G1969-85003
Contains 7 x 2 mL ampoules with 5 mM purine, 1 M ammonium formate, 0.5 mM HP-0285,
0.1 mM HP-0321,0.2 mM HP-1221, 0.2 mM HP-1821, 0.5 mM HP-2421
HSA peptide standard mix kit G2455-85001
2 vials with 6 lyophilized peptides
www.AGILEnt.COM/ChEM/LC 15
AGILEnt PArtS And SuPPLIES
LC Capillaries
Your LC system’s components
are only as reliable as
the connections between them
Think of your LC system as a chain from analyte… to pump… to column… to detector… to waste. Every link
must operate at maximum efficiency, or the whole chain risks failure – compromising your results.
Agilent LC capillaries:
Agilent’s unique laser welding process ensures that
Your link to analytical success
the capillary ends are absolutely flat, eliminating
any chance of capillary-induced dead volume. At Agilent, we invest heavily in the quality of our capillary connections. All are engineered and
manufactured to the same quality standards as our columns and instruments, so you can protect the
integrity of your results at every step of your LC flow path.
Using our flexible stainless steel and polymer capillaries and fittings can provide:
• Tight, leak-free connections
• Zero dead volume connections
• An inert surface (when using polymer or PEEK/stainless steel bio-inert capillaries)
• High flexibility without sacrificing durability
• Easy cutting to the exact length you need (PEEK tubing)
• Predefined lengths for specific flow path locations (capillaries)
In addition, all Agilent capillaries are precision cut with square ends, are burr-free, have no inner-diameter
distortion, and come in a variety of materials to suit your needs.
16
AGILEnt PArtS And SuPPLIES
www.AGILEnt.COM/ChEM/LC 17
AGILEnt PArtS And SuPPLIES
Tip: As you move to smaller-volume, high efficiency columns, you’ll want to use narrow id tubing, as
opposed to the wider id tubing used for conventional HPLC instruments.
18
AGILEnt PArtS And SuPPLIES
www.AGILEnt.COM/ChEM/LC 19
AGILEnt PArtS And SuPPLIES
20
AGILEnt PArtS And SuPPLIES
Internal
diameter Pressure limit
Category Applications (mm) (bar) ph range Comments
Stainless steel ü All capillary applications, 0.075 1200 1-14 ü Flexible for easy routing
except where bio-inertness is required 0.12 ü Ready to use: cleaned and
ü 1/32 in od designed for 0.17 passivated to a high standard
Agilent 1100 systems 0.25 ü Pre-cut capillaries are optimized
ü 1/16 in and 1/8 in od for most 0.3 for the lowest internal volume
0.5
applications ü Use pre-cut lengths to maintain
0.61
zero-dead-volume performance
0.93
Titanium ü Where ultimate bio-inertness is essential 0.17 600 1-14
0.61
Stainless-steel-coated ü Universal for standard 0.17 600 1-14 ü Metal-free flow path
PEEK and bio-inert applications ü Robust
ü UHPLC bio-inert applications ü Flexible
ü Resists corrosion better than
stainless steel
PEEK-coated fused silica ü Industry standard for most LC applications 0.025 690 1-10 ü Mechanically strong
0.050 ü Consistent, rigid flow path
0.075 ü Ideal replacement for
0.100 stainless steel
0.125
ü To avoid permanent tube damage,
always use pre-cut lengths
PEEK ü Most HPLC applications 0.13 480* 1-14 ü Smooth internal surface minimizes
0.18 200** turbulence for improved
0.25 resolution
0.50 ü Flexible, easily cut to length
ü Use with PEEK or stainless
steel fittings
ü Excellent solvent compatibility
*At ambient temperature with water
**With acetonitrile at non-ambient temperature
www.AGILEnt.COM/ChEM/LC 21
AGILEnt PArtS And SuPPLIES
• Stainless steel or PEEK delivers permanent high-pressure sealing performance for connections
such as valves, heaters, and columns
• Stainless steel ensures permanent high-pressure sealing and optimal performance throughout
your LC system up to 1200 bar
• Finger-tight fittings (polymeric for 400 bar and polyketone for 600 bar) are a convenient option;
They allow easy end fitting adjustment, so you can seat the capillary into the column properly,
preventing extra-column voids and leaks
• High-pressure fittings, which can be used with pressures up to 1200 bar, can be removed and replaced
• It’s a good idea to use stainless steel nuts and ferrules for instrument connections, and PEEK nuts
and ferrules for column and guard column connections, since these are changed most frequently
22
AGILEnt PArtS And SuPPLIES
Material
Key description
SS Stainless steel
PK PEEK
PTFE PTFE
FS Fused silica
S Swagelok 1.6 mm port id
SH Swagelok 1.6 mm port id, long head
U Swagelok union
www.AGILEnt.COM/ChEM/LC 23
AGILEnt PArtS And SuPPLIES
Stainless steel fittings (S), 5062-2418 Finger-tight PEEK fitting (SPF), 0100-1516 Stainless steel back ferrule, 5180-4114
Images shown are capillary fittings. For complete information on fittings, turn to page 40.
24
AGILEnt PArtS And SuPPLIES
(Continued)
Material
Key description
SS Stainless steel
S Swagelok 1.6 mm port id
SH Swagelok 1.6 mm port id, long head
SL Swagelok 1.6 mm port id, long
SLV Swagelok 1.6 mm port id, long, 1200 bar
SX Swagelok 1.6 mm port id, extra-long
M Metric M4 0.8 mm port id
www.AGILEnt.COM/ChEM/LC 25
AGILEnt PArtS And SuPPLIES
Stainless steel fittings (S), 5062-2418 Stainless steel extra long fitting (SX), 5065-9967 1200 bar removable long fitting (SLV), 5067-4738
1200 bar removable fitting (SV), 5067-4733 PEEK fittings, plugs (MP), 5065-4410
Images shown are capillary fittings. For complete information on fittings, turn to page 40.
26
AGILEnt PArtS And SuPPLIES
Miscellaneous Capillaries
Fitting Fitting Od Od
type From type to (mm) (mm)
Material Id (mm) Length (mm) (A) (B) A* B* notes Part no.
SS 0.12 70 S S 1.6 1.6 G1316-87303
SS 0.12 2000 U U Restriction Capillary 5022-2159
SS 0.12 105 1.6 1.6 Capillary without fitting 5021-1820
SS 0.12 400 1.6 1.6 Capillary without fitting 5021-1823
SS 0.12 150 1.6 1.6 Capillary without fitting 5021-1821
SS 0.12 280 1.6 1.6 Capillary without fitting 5021-1822
SS 0.12 500 1.6 1.6 Capillary without fitting 5065-9964
SS 0.12 200 1.6 1.6 Capillary without fitting 5065-9935
SS 0.12 50 S U 1.6 G1316-87312
SS 0.12 340 S S 1.6 1.6 G1316-87319
SS 0.12 170 S S 1.6 1.6 G1316-87316
SS 0.12 300 S S 1.6 1.6 G1316-87318
SS 0.12 210 S S 1.6 1.6 G1316-87317
SS 0.12 70 S U 1.6 G1316-87313
SS 0.12 90 S U 1.6 G1316-87314
SS 0.12 60 S S Pre-swaged on A and B 79841-87610
SS 0.12 340 S M 0.8 Pre-swaged on A G1316-87305
*1.6 mm = 1/16 in
(Continued)
Material
Key description
SS Stainless steel
S Swagelok 1.6 mm port id
U Swagelok union
SL Swagelok 1.6 mm port id, long
SLV Swagelok 1.6 mm port id, long, 1200 bar
SX Swagelok 1.6 mm port id, extra-long
M Metric M4 0.8 mm port id
Stainless steel fittings (S), 5062-2418
Images shown are capillary fittings. For complete information on fittings, turn to page 40.
www.AGILEnt.COM/ChEM/LC 27
AGILEnt PArtS And SuPPLIES
Miscellaneous Capillaries
Fitting Fitting Od Od
type From type to (mm) (mm)
Material Id (mm) Length (mm) (A) (B) A* B* notes Part no.
SS 0.12 100 M M 0.8 0.8 G1316-27301
SS 0.12 75 S M 1.6 0.8 G1316-87306
SS 0.12 90 S SX 1.6 1.6 5067-4685
SS 0.12 120 SX SX 1.6 1.6 5067-4688
SS 0.17 105 1.6 1.6 Capillary without fitting 5021-1816
SS 0.17 400 1.6 1.6 Capillary without fitting 5021-1819
SS 0.17 150 1.6 1.6 Capillary without fitting 5021-1817
SS 0.17 280 1.6 1.6 Capillary without fitting 5021-1818
SS 0.17 280 S S 1.6 1.6 Pre-swaged on A 01090-87304
SS 0.17 200 1.6 1.6 Capillary without fitting 5065-9931
SS 0.17 600 1.6 1.6 Capillary without fitting 5065-9933
SS 0.17 800 S S 1.6 1.6 Pre-swaged on A 01048-87302
SS 0.17 900 1.6 1.6 Capillary without fitting 5065-9963
SS 0.17 105 S S 1.6 1.6 G1316-87321
SS 0.17 700 1.6 1.6 Capillary without fitting 5065-9932
SS 0.17 170 S S 1.6 1.6 G1316-87323
SS 0.17 250 S S 1.6 1.6 Pre-swaged on A and B G1367-87304
SS 0.17 150 S S 1.6 1.6 Pre-swaged on A and B G1312-87305
SS 0.17 800 SL S 1.6 1.6 Pre-swaged on A 01078-87305
SS 0.17 105 S S 1.6 1.6 Pre-swaged on A and B G1312-87306
SS 0.17 280 SX S 1.6 1.6 Pre-swaged on A and B 5067-4608
SS 0.17 700 S SX 1.6 1.6 Pre-swaged on A and B 5067-4648
SS 0.17 150 M M 0.8 0.8 5067-4737
SS 0.17 700 SL M 1.6 0.8 Pre-swaged on A 5067-5120
*1.6 mm = 1/16 in
(Continued)
Stainless steel extra long fitting (SX), 5065-9967 Stainless steel ferrule (M), 5067-1557
Images shown are capillary fittings. For complete information on fittings, turn to page 40.
28
AGILEnt PArtS And SuPPLIES
Miscellaneous Capillaries
Fitting Fitting Od Od
type From type to (mm) (mm)
Material Id (mm) Length (mm) (A) (B) A* B* notes Part no.
SS 0.17 280 SX SX 1.6 1.6 Pre-swaged on A and B 5067-4607
SS 0.17 280 SX S 1.6 1.6 Pre-swaged on A and B 5067-4608
SS 0.17 400 1.6 1.6 Capillary without fitting 5021-1819
SS 0.17 500 SX Nut 1.6 1.6 Pre-swaged on A 5067-4609
(P/N
0100-2086)
SS 0.17 600 1.6 1.6 Capillary without fitting 5065-9933
PK/SS 0.17 100 1.6 1.6 Capillary without fitting 5067-4777
PK/SS 0.17 150 1.6 1.6 Capillary without fitting 5067-4778
PK/SS 0.17 200 1.6 1.6 Capillary without fitting 5067-4779
PK/SS 0.17 300 1.6 1.6 Capillary without fitting 5067-4780
PK/SS 0.17 400 1.6 1.6 Capillary without fitting 5067-4781
PK/SS 0.17 500 1.6 1.6 Capillary without fitting 5067-4782
SS 0.25 320 S S 1.6 1.6 Pre-swaged on A and B 79835-87638
SS 0.5 105 1.6 1.6 Capillary without fitting 5065-9927
SS 0.5 150 1.6 1.6 Capillary without fitting 5022-6509
SS 0.5 200 1.6 1.6 Capillary without fitting 5022-6510
SS 0.5 800 1.6 1.6 Capillary without fitting 5065-9926
*1.6 mm = 1/16 in
Material
Key description
SS Stainless steel
PK PEEK
PK/SS PEEK and Stainless steel
Ti Titanium
S Swagelok 1.6 mm port id
U Swagelok union
SL Swagelok 1.6 mm port id, long
SLB Swagelok 1.6 mm port id, long bio
Stainless steel fittings (S), 5062-2418
SV Swagelok 1.6 mm port id, 1200 bar
SLV Swagelok 1.6 mm port id, long, 1200 bar
SX Swagelok 1.6 mm port id, extra-long
Stainless steel extra long fitting (SX), 5065-9967 Stainless steel ferrule (M), 5067-1557
Images shown are capillary fittings. For complete information on fittings, turn to page 40.
www.AGILEnt.COM/ChEM/LC 29
AGILEnt PArtS And SuPPLIES
1200 bar removable fitting (SV), 1200 bar removable long fitting (SLV), Titanium fitting (SLB), Bio-inert Low Dispersion
5067-4733 5067-4738 G5611-60502 Heat Exchanger, G5616-60050
Images shown are capillary fittings. For complete information on fittings, turn to page 40.
30
AGILEnt PArtS And SuPPLIES
Stainless steel fittings, male (G), Ferrule and stainless steel lock ring PEEK fittings, plugs (MP), 5065-4410 Double winged PEEK nut & ferrule
5063-6593 (W), 5065-4423 (WPF), 5065-4422
Images shown are capillary fittings. For complete information on fittings, turn to page 40.
www.AGILEnt.COM/ChEM/LC 31
AGILEnt PArtS And SuPPLIES
Loop Capillaries
volume (µL) Agilent Autosampler Part no.
8 G1389A G1375-87303
G1377A G1375-87315
20 G1367E, G4226A G4226-60310
40 G1367D G1377-87310
G1367E, G4226A 5067-4703
G1377A G1377-87300
G1389A G1329-87302
100 G1313A, G1329A/B, 1120, 1220 Infinity LC 01078-87302
G1367A/B/C G1367-87300
G1367E, G4226A 5067-4710
G5667A G5667-60310
900 G1329A/B, G2260A G1313-87303
5000 G2260A G2260-68711
Material
Key description
FS/PK Fused silica/PEEK
W Swagelok 0.8 mm port id
WG Swagelok 0.8 mm port id, small head
SW 4 mm
MP Metric M4 0.8 mm port id, PEEK
WPF Swagelok 0.8 mm port id, PEEK, finger-tight
32
AGILEnt PArtS And SuPPLIES
Material
Key description
SS Stainless steel
S Swagelok 1.6 mm port id
PK PEEK
PTFE PTFE
Images shown are capillary fittings. For complete information on fittings, turn to page 40.
www.AGILEnt.COM/ChEM/LC 33
AGILEnt PArtS And SuPPLIES
Tubing
PEEK tubing
• Flexible and easy to cut to desired lengths
• Color coded for easy tracking
• Accepts both stainless steel and PEEK fittings
• 1/16 in od
PEEK tubing
Id (mm) Length (m) Color Code Part no.
0.50 1.5 Orange 0890-1761
0.25 1.5 Blue 0890-1762
0.25 5 Blue 5042-6463
0.18 1.5 Yellow 0890-1763
0.18 5 Yellow 5042-6462
0.13 1.5 Red 0890-1915
0.13 5 Red 5042-6461
Other tubing
description Length (m) Id (mm) Od (mm) Part no.
PTFE tubing, FEP, primary use for valve solutions 5 0.7 1.6 5062-2462
PTFE solvent tubing, primary use for flow path from solvent bottle to degasser, to pump 5 1.5 3.1 5062-2483
Corrugated tubing, polypropylene 5 6.5 5062-2463
Silicone tubing 5 1 3 5065-9978
Clamps and micro clamps, 10/pk 5065-9976
Barbed Y-Connector PP for 3/16 in id tube, 10/pk 5065-9971
For G2258A 1100/1200 Series dual Loop Autosampler
Front seat tube, SS 0.1 0.5 G2258-87316
Back seat tube, SS 0.12 0.5 G2258-87315
Front seat tube, PTFE 0.1 0.2 G2258-87312
Back seat tube, PTFE 0.12 0.25 G2258-87313
Waste tube 0.15 0.8 G2258-87310
Waste tube 0.1 0.8 G2258-87311
Drawing tube assembly for flush solvent G2258-87307
Tubing assembly, solvent flush G2258-87314
For G1313/27/29A 1100/1200 Series Autosampler
Waste tube G1313-87300
Corrugated tubing, polypropylene 5 6.5 5062-2463
For G1387A 1100/1200 Series Micro Autosampler
Waste tube, FEP 0.8 1.6 G1375-87326
34
AGILEnt PArtS And SuPPLIES
Accessories
description Part no.
Plastic tubing cutter 8710-1930
Blades for plastic cutter, 5/pk 8710-1931
Fitting screws, stainless steel, 10-32, 4 mm, 5/pk 5065-9948
PEEK ferrule and stainless steel ring for 2 mm tube, 5/pk 5065-9950
Plastic tubing cutter, 8710-1930
Union, PEEK for 1/8 in od tubing 0100-2410
Waste adapter, 1200 Series autosamplers, gray G1313-43216
www.AGILEnt.COM/ChEM/LC 35
AGILEnt PArtS And SuPPLIES
(Continued)
36
AGILEnt PArtS And SuPPLIES
(Continued)
www.AGILEnt.COM/ChEM/LC 37
AGILEnt PArtS And SuPPLIES
(Continued)
38
AGILEnt PArtS And SuPPLIES
www.AGILEnt.COM/ChEM/LC 39
AGILEnt PArtS And SuPPLIES
Fittings
description Key unit Part no.
Stainless steel fittings (S), PEEK fittings (SPF), Swagelok 1.6 mm stainless steel fitting S 10/pk 5062-2418
5062-2418 0100-1516/5063-6591 Swagelok 1.6 mm stainless steel fitting, SL 10/pk 5065-4454
long screw
Swagelok 1.6 mm stainless steel fitting, SX 10/pk 5065-9967
extra long screw
Swagelok 1.6 mm screw 10/pk 5061-3303
Stainless steel long fittings (SL), Finger-tight PEEK fitting (SPF), 1.6 mm stainless steel front ferrule 10/pk 5180-4108
5065-4454 0100-1516
1.6 mm stainless steel back ferrule 10/pk 5180-4114
Swagelok 1.6 mm 1200 bar removable fitting SV 1/ea 5067-4733
Swagelok 1.6 mm 1200 bar SLV 1/ea 5067-4738
removable fitting, long screw
Swagelok 1.6 mm 1200 bar SXV 1/ea 5067-4739
Stainless steel extra long fitting (SX), PEEK long fittings (SPFL), removable fitting, extra long screw
5065-9967 5062-8541
Swagelok 1.6 mm finger-tight PEEK fitting SPF 10/pk 5063-6591
Swagelok 1.6 mm PEEK finger-tight fitting SPF 2/pk 0100-1516
Swagelok 1.6 mm PEEK finger-tight SPLF 10/pk 5062-8541
long fitting
Swagelok 1.6 mm PEEK finger-tight fitting SPF 10/pk 5065-4426
Stainless steel nut, Finger-tight PEEK fittings (SPF), (mixed colors)
5061-3303 5065-4426
Swagelok 1.6 mm finger-tight PEEK SPF 10/pk 5042-6500
double winged fitting
Swagelok 1.6 mm finger-tight PEEK SPF 5/pk 0100-1631
Rheflex fitting
Swagelok 1.6 mm finger-tight PEEK SPF 10/pk 0100-2175
Stainless steel front ferrules, Double winged fitting (SPF), Rheflex fitting (mixed color)
5180-4108 5042-6500 Swagelok 1.6 mm stainless steel blanking nut S 1/ea 01080-83202
Material
Key description
Stainless steel back ferrule, PEEK RheFlex fittings (SPF), S Swagelok 1.6 mm port id
5180-4114 0100-1631 SL Swagelok 1.6 mm port id, long
SX Swagelok 1.6 mm port id, extra-long
SV Swagelok 1.6 mm port id, 1200 bar
SLV Swagelok 1.6 mm port id, long, 1200 bar
1200 bar removable fitting (SV), PEEK RheFlex fittings (SPF), SLB Swagelok 1.6 mm port id, long bio
5067-4733 0100-2175 SXV Swagelok 1.6 mm port id, extra-long, 1200 bar
SPF Swagelok 1.6 mm port id, PEEK, finger-tight
SPLF Swagelok 1.6 mm port id, PEEK, long, finger-tight
1200 bar removable long fitting (SLV), Stainless steel blanking nut,
5067-4738 01080-83202
40
AGILEnt PArtS And SuPPLIES
Fittings
description Key unit Part no.
Swagelok 1.6 mm stainless steel screw S 6/pk 5067-1540 Stainless steel nut and PEEK Ferrule and stainless steel lock ring
for PEEK ferrule 5067-1547 ferrule, 5067-1540 (W), 5065-4423
Swagelok stainless steel screw SP 1/ea 0100-2086
with 1.6 mm PEEK ferrule
1.6 mm PEEK ferrule for 5067-1540 screw SP 6/pk 5067-1547
Swagelok 1.6 mm finger-tight SPF 10/pk 5042-8957
polyketone fitting PEEK ferrule, PEEK fittings, plugs (MP),
M4 stainless steel screw for stainless steel M 6/pk 5067-1558 5067-1547 5065-4410
ferrule 5067-1557
0.8 mm stainless steel ferrule M 6/pk 5067-1557
for 5067-1558 screw
Swagelok 1.6 mm plastic blank nut M 1/ea 0100-1259
Swagelok 1.6 mm ST screw, 4 mm head G 10/pk 5063-6593 Finger-tight polyketone fitting
0.8 mm PEEK ferrule and stainless steel ring W 10/pk 5065-4423 (SPF), 5042-8957
for 5063-6593 screw Double winged PEEK nut & ferrule
(WPF), 5065-4422
M4 0.8 mm PEEK fitting MP 6 fittings, 5065-4410
2 plugs
Swagelok 0.8 mm finger-tight PEEK WPF 10/pk 5065-4422
double winged fitting
M4 stainless steel screw,
Swagelok 0.8 mm finger-tight PEEK WPFL 1/ea 5022-6536 5067-1558
long fitting
Swagelok 2.0 mm stainless steel screw, 5/pk 5065-9948 PEEk fitting, long (WPFL),
4 mm head 5022-6536
2.0 mm PEEK ferrule and stainless steel ring 5/pk 5065-9950
www.AGILEnt.COM/ChEM/LC 41
AGILEnt PArtS And SuPPLIES
unions
description use with Part no.
ZDV union, no fittings Nano LC 5022-2145
Adapter, PEEK, 0100-2298
ZDV union, 5022-2145 ZDV universal union, stainless steel, Standard LC 5022-2184
no fittings
ZDV union, with fittings Standard LC 0100-0900
ZDV union, PEEK with fittings Bio-applications 0100-2441
High flow union, no fittings Prep LC 5022-2133
PEEK adapter 1/4-28 to 10-32 0100-1847
ZDV universal union, 5022-2184 Barbed Y-connector PP, 5065-9971 Adapter, PEEK int. 1/4-28 to ext. 10-32 0100-2298
Barbed Y-connector PP 5065-9971
for 3/16 in id tube, 10/pk
Adapter, union PEEK 1/4-28 5042-8517
Adapter, male Luer to female 1/4-28 5042-8518
SS adapter Swagelok to 1/4-28 5023-1803
ZDV union with fittings, 0100-0900 Union, female to female, 5042-8517
T-connector, PEEK, swept volume 0.57 µL For 1/16 in 5022-2144
od tubing
Micro T-connector, PEEK, swept volume 5042-8519
29 mL, with 1/32 in id fittings
Bio-inert union, stainless steel Bio-applications 5067-4741
with PEEK insert 600 bar
ZDV union, PEEK with fittings, 0100-2441
42
AGILEnt PArtS And SuPPLIES
www.AGILEnt.COM/ChEM/LC 43
AGILEnt PArtS And SuPPLIES
Ideally, you should use the fittings recommended by your column manufacturer. Most analytical reversed phase columns are compatible with Swagelok
or Parker-type fittings when correctly seated in the column.
Stainless steel fittings are the best choice for permanent, high-pressure sealing. Agilent recommends Swagelok-type fittings with front and back ferrules,
because they deliver the best performance for Agilent LC systems – and can be used on most instrument connections, including valves, heaters, and
column connections.
For lower-pressure operation, finger-tight polymeric fittings allow you to easily adjust the end-fitting to seat the capillary into the column properly –
helping avoid extra-column voids and leaks. These connectors can be tightened without wrenches. High-pressure fittings, which are designed
to be removed and resealed, are also available for pressures up to 1200 bar.
44
AGILEnt PArtS And SuPPLIES
1. Select a nut that is long enough for the fitting you’ll be using.
2. Slide the nut over the end of the tubing.
3. Carefully slide the ferrule components on after the nut, then finger-tighten the assembly while making sure the tubing is completely seated in the
bottom of the end fitting.
4. Use a wrench to gently tighten the fitting; this will force the ferrule to seat onto the tubing, ½ to ¾ turn with a wrench. Do not over-tighten!
That will shorten the useful life of the fitting.
5. Once you are sure your fitting is complete, loosen the nut and inspect the ferrule for correct position on the tubing.
note: Avoid re-using a capillary on a different location. The position of the fitting is done the first time it is screwed on a port and all the ports are
not strictly identical.
1. 2. 3. 4. 5.
www.AGILEnt.COM/ChEM/LC 45
AGILEnt PArtS And SuPPLIES
46
AGILEnt PArtS And SuPPLIES
Pump Supplies
Regular pump maintenance helps lower operating costs and generate precise results that make
you feel confident.
You can count on Agilent isocratic, binary, quaternary, capillary, and preparative pumps for superior flow
and composition stability. And by following a regular maintenance routine, you can also count on maximum
uptime and a steady, accurate solvent flow for the life of the pump.
Sapphire piston and seals
www.AGILEnt.COM/ChEM/LC 47
AGILEnt PArtS And SuPPLIES
Purge valves
description Comments Part no.
Purge valve with PTFE frit, For G1310A, G1311A, G1312A, G1376A, G2226A G1311-60009
400 bar
Purge valve with PTFE frit For 1120 G4280-60031
Purge valve assembly, G1311-60009 Purge valve with PTFE frit For G1311C, G1312C, 1220 G4280-60061
Purge valve with PTFE frit For G1310B, G1311B, G1312B, G4302A, G1312-60061
PTFE frit For G1310A, G1311A, G1312A, G1376A, G2226A, 01018-22707
1120, 1220, 1220, G1310B, G1311B, G1312B, G1311C,
G1312C, G4202A
Seal cap Not suitable for outlet ball valves with integrated seal 5067-4728
Seal for purge valve For 1120 0905-1192
Purge valve actuator For 1120 G4280-60033
Bio-inert purge valve For G5611A G5611-60061
5 position / 7 port rotor seal For G4220A, G4220B 5068-0005
Purge valve with PTFE frit, G4280-60061
5 position / 7 port stator For G4220A, G4220B 5068-0004
Multi purpose valve head For G4204A 5067-4174
Stator for 5067-4174 For G4204A 5068-0122
multi purpose valve head
Rotor for 5067-4174 G4204A 5068-0123
multi purpose valve head
Stainless steel filter assembly For G1361A 5022-2192
with PEEK ring,
2 µm pore size
Open end wrench, 14 mm To remove purge valve 8710-1924
PTFE frits, 01018-22707
48
AGILEnt PArtS And SuPPLIES
Inlet valves
description Comments Part no.
Active inlet valve For G1310A, G1311A, G1312A, G1376A, G1312-60025
without cartridge G2226A, G1312B, G1312C
Cartridge for active inlet valve For G1310A, G1311A, G1312A, G1376A, 5062-8562 Active inlet valve without cartridge, G1312-60025
400 bar G2226A, G1312C
Cartridge for active inlet valve For G1312B G1312-60020
600 bar
Bio-inert active inlet valve For G5611A G5611-60025
Bio-inert cartridge for active For G5611A G5611-60020
inlet valve, 600 bar
Cartridge, 400 bar, 5062-8562
Inlet valve for For G4204A G4204-60022*
1290 quaternary pump
Valve assemblies (inlet/outlet) For G1361A G1361-60012
for prep pumps
Passive inlet valve For G1310B, G1311B, G1311C, 1120, 1220, G1312-60066*
G4302A
Passive inlet valve For G4220A, G4220B G4220-60022*
Passive inlet valve, G1312-60066
Seal cap Not suitable for outlet ball valves with integrated seal 5067-4728
*Inlet valve with integrated seal.
Outlet valves
description Comments Part no.
Outlet ball valve For G1310A, G1311A, G1312A,G1376A, G2226A, G1312-60067*
Seal cap, 5067-4728
1120, 1220, G1310B, G1311B, G1311C, G1312B,
G1312C, G4302A
Outlet ball valve For G4220A, G4220B, G4204A G4220-60028*
Bio-inert outlet ball valve For G5611A G5611-60067*
Valve assemblies (inlet/outlet) For G1361A G1361-60012
for prep pumps
Seal cap Not suitable for outlet ball valves with integrated seal 5067-4728
*Outlet ball valve with integrated seal. Outlet ball valve, G1312-60067
www.AGILEnt.COM/ChEM/LC 49
AGILEnt PArtS And SuPPLIES
• Meticulously cut at just the right angle, making them durable – and long lasting
• Precisely aligned in their stainless steel holder to minimize wear on the piston and seal
Sapphire piston and seals Agilent seals are designed to fit snugly around our pistons, and are capable of adapting to a wide range
of flow rates and pressures. Agilent piston seals are:
• Spring-loaded and engineered to deliver optimal performance over highly dynamic flow and
pressure ranges
• Manufactured from a proprietary polymer blend, and feature a spring made from the same high-quality
stainless steel that is used in our pump's flow path
The combination of our piston and seal has undergone extensive testing under temperature stress,
with all common HPLC solvents, and in many instruments. More importantly, they yield consistent,
reproducible results.
Pistons
description Comments Part no.
Sapphire plunger For G5611A, 4302A 5067-4695
Zirconium based For G4220A, G4220B, G4204A 5067-4678
ceramic plunger
Sapphire plunger For G1310A, G1311A, G1312A, G1376A, G2226A, 1120, 5063-6586
1220, G1310B, G1311B, G1312B, G1311C, G1312C
Sapphire plunger For G1361A G1361-22402
50
AGILEnt PArtS And SuPPLIES
Seals
description Comments Part no.
Bio-inert piston seal For G5611A G5611-21503
Piston seal polyethylene For G4220A, G4220B, G4204A 0905-1719
Piston seal graphite filled For G1310A, G1311A, G1312A, G1376A, G2226A, 5063-6589
PTFE (reversed-phase) 1120, 1220, G1310B, G1311B, G1312B, G1311C, Piston seals, 5063-6589
(2/pk) G1312C, G4302A
Piston seal Polyethylene For G1310A, G1311A, G1312A, G1376A, G2226A, 0905-1420
(normal phase) 1120, 1220, G1310B, G1311B, G1312B, G1311C,
G1312C, G4302A
Piston seal For G1361A 5022-2188
www.AGILEnt.COM/ChEM/LC 51
AGILEnt PArtS And SuPPLIES
Seal wash
The routine use of highly concentrated buffer solutions (100 mM) will reduce the life of seals and pistons in
your pump. Counteract the problem with one of Agilent's seal wash kits, which flush the back of the seal
with a wash solvent. note: Water/isopropanol (90/10) is recommended as the wash solvent.
Peristaltic pump, 5042-8507
Seal wash
description Comments Part no.
Peristaltic pump cassette For 1100/1200/1200 RRLC and 1260 Infinity LC pumps 5042-8507
with silicone tubing
Silicone tubing, 1 mm id, 5065-9978
3 mm od, 5 m
Peristalitic pump For 1100/1200/1200 RRLC and 1260 Infinity LC pumps 5065-9952
with ChemSure tubing
ChemSure tubing 5042-8954
for peristaltic pump
Peristalitic pump with ChemSure tubing,
wash Seal and wash Keeper
5065-9952
Wash seal For 1100/1200/1200 RRLC, 0905-1175
1120 and 1260/1220 Infinity LC pumps
Seal keeper For 1100/1200/1200 RRLC and 1120 pumps 5001-3743
Bio-inert seal keeper For G5611A LC pump G5611-26210
Wash seal gasket, 6/pk For 1100/1200/1200 RRLC, 5062-2484
1120 and 1260/1220 Infinity LC pumps
Wash seal PE For 1290/1260/1220 Infinity LC pump 0905-1718
Support ring For 1290/1260/1220 Infinity LC pump G4220-63010
Support ring For 1290 Infinity pump without seal wash G4220-63015
Backup ring for seal holder For 1290/1260/1220 Infinity LC pump G4220-24013
Seal keeper For 1290/1260/1220 Infinity LC pump G4220-26210
52
AGILEnt PArtS And SuPPLIES
www.AGILEnt.COM/ChEM/LC 53
AGILEnt PArtS And SuPPLIES
Solvent Filters
Frit Inlet tube Od
description recommended use Part no. Frit Adapter Part no. Id (mm) (mm)
Glass filter, solvent inlet, Analytical scale, 5041-2168 Frit adapter, PTFE, 3 mm, 4/pk 5062-8517 5 3.2
20 µm pore size micro scale
Glass filter, solvent inlet, Preparative LC 3150-0944 Frit adapter, PTFE for 4.7 mm od tubing G1361-23205 7 4.7
40 µm pore size
Glass filter, solvent inlet, Preparative LC 3150-0944 Frit adapter, PTFE, 4 mm G1361-23204 7 4
40 µm pore size
Glass filter, solvent inlet, For G2258A Dual 3150-0944 Frit adapter, PTFE for 3.2 mm od tubing G2258-23201 7 3.2
40 µm pore size Loop Autosampler
Solvent inlet filter, stainless steel For use in capillary 01018-60025
and nano systems
54
AGILEnt PArtS And SuPPLIES
Safety Caps
Open or partially covered solvent bottles can lead to the evaporation of solvents and harmful solvent vapors.
Prevent solvent evaporation and possible chemical spills with solvent safety caps from Agilent. These safety
caps have been designed for optimal sealing with an integrated exhaust valve providing pressurization
during solvent extraction and allowing proper solvent flow to your HPLC system. The exhaust valve contains
a PTFE membrane to prevent contamination of your solvents from dirt and dust particles.
Installation Instructions for Safety Caps with Stopcocks Safety Cap I, 5043-0223
These caps have a shut-off valve which can be closed. This keeps the solvent tube
in the bottle during maintenance activities with no risk of having solvent dropping out
of the flow path.
www.AGILEnt.COM/ChEM/LC 55
AGILEnt PArtS And SuPPLIES
56
AGILEnt PArtS And SuPPLIES
www.AGILEnt.COM/ChEM/LC 57
AgileNt PArts AND suPPlies
Vacuum Degassers
A vacuum degasser is recommended for:
Vacuum Degassers
Description Comments Part No.
Tubing kit, degasser to pump, 4/pk, 30 cm pieces of tubing For G1322A, G1379A/B G1322-67300
with screws and bushings
Inlet tubing For Agilent 1260 Infinity 5067-5378
Quaternary Pump VL
Plastic tubing cutter, 8710-1930 Mounting tool for flangeless nut For G1322A, G1379A/B 0100-1710
Plastic tubing cutter For G1322A, G1379A/B 8710-1930
Tefzel ferrules and SS lock rings, 1/8 in, 10/pk For G1322A, G1379A/B 5063-6598
PPS nuts, 1/8 in, 1/4-28 thread, 10/pk For G1322A, G1379A/B 5063-6599
Union, 1/4-28 thread, polypropylene For G1322A, G1379A/B 5022-2155
PTFE solvent tubing, 5 m, 1.5 mm id, 3 mm od For G1322A, G1379A/B 5062-2483
Disposable syringes, 20 mL, 10/pk For G1322A 5062-8534
Syringe adapter, 1/16 in od, 2 in long For G1322A 9301-1337
Micro vacuum degasser tubing kit For G1379A G1379-67310
Ferrules and rings, 5063-6598
Micro vacuum degasser tubing kit For G1379B 5042-8922
Online degasser accessory kit For G1322A, G1379A/B G1322-68705
Includes 8 screws, 8 bushings, 4 markers, tubing,
syringe and syringe adapter
Vaccum chamber (2 channel) For G1379A, G1379B 5067-4798
Tubing kit for 5067-4798 vaccum chamber For G1379A, G1379B 5067-5380
Vaccum chamber replacement kit For G1379A, G1379B 5067-5383
Includes two 5067-4798 and one 5067-5380
58
AgileNt PArts AND suPPlies
Pump Kits
Pump Kits
Description Kit Contents Part No.
start-up Kits
Pump start-up kit Includes 1 outlet cap, 5 PTFE frits, 4 piston seals, 1 outlet gold seal, 2 glass solvent inlet G1311-68710
For 1100/1200/1220 RRLC pumps filters, 20 µm, and 1 cartridge for active inlet valve
Nanoflow LC start-up kit Includes PEEK coated fused silica capillaries, column and fittings to start up a Nanoflow G2228-68700
LC System
seal Wash Kits
Active seal wash kit Includes 2 wash seal gaskets, 2 pump seals, peristaltic pump (includes pump cassette G1311-68711
and motor), 2 seal keepers, 2 support ring assemblies, seal insert tool and silicone tubing
Active seal wash kit Includes 4 wash seal gaskets, 4 pump seals, 2 peristaltic pumps (includes pump cassette G1312-68711
and motor), 4 seal keepers, 4 support ring assemblies, seal insert tool and silicone tubing
Continuous seal wash kit Includes 2 wash seal gaskets, 4 m flex tubing, 2 pump seals, 1 flow regulator, 2 seal 01018-68722
For 1100/1200/1200 RRLC pumps keepers, 2 support ring assemblies, 20 mL luer lock syringe, seal insert tool and abrasive
paper
Seal wash kit for 1260 Capillary/Nano pump Includes 3 adaptor luer/barbs, 2 film washers, 1 insert tool, 2 seal pumps, 1 clamp hose, G1376-60005
2 seal wash, 1 syringe, 2 support ring 1290 Infinity LC w/seal wash, 2 seal keepers for
1290 Infinity LC, and 2 backup rings for seal keeper 1290 Infinity
Seal wash PM kit Includes 2 PTFE wash seals (P/N 0905-1175), 2 gasket wash seals (P/N 01018-07102) G1310-68742
For 1260 Infinity LC pumps
PM kit for seal wash option Includes 2 wash seals and 1 pack of 6 wash seal gaskets G1310-68731
Preventive Maintenance Kits
For 1260 Infinity LC isocratic or quaternary Includes 1 PTFE pump seal (P/N 0905-1503), PTFE frits, 5/pk (P/N 01018-22707), G1310-68741
and 1220 pumps 1 seal cap (P/N 5067-4728)
For 1260 Infinity LC binary pump Includes 1 PTFE pump seals (P/N 0905-1503), PTFE frits, 5/pk (P/N 01018-22707), G1312-68741
1 seal cap (P/N 5067-4728), sieves for outlet valve, 10/pk (P/N 5063-6505)
For 1100/1200 isocratic or quaternary pumps Includes piston seal, PTFE frits, and 2 seal caps G1310-68730
For 1290 Infinity pump Includes pump seal exchange tool, torque wrench, and hex bit 5067-4699
For Bio-inert quaternary pump Includes bio-inert piston seal, 5/pk PTFE frits, seal cap assembly, film washer, peristaltic G5611-68741
pump, silicone tubing, Bio-inert wash seal
(Continued)
WWW.AgileNt.CoM/CheM/lC 59
AgileNt PArts AND suPPlies
Pump Kits
Description Kit Contents Part No.
Preventive Maintenance Kits
For 1100/1200 binary pump Includes 4 piston seals, PTFE frits, 2 sieves, and 3 seal caps G1312-68730
For G1376A capillary pump Includes 4 pump seals, 1 stainless steel frit, and 4 seal cap assemblies G1376-68710
For 1100/1200 and Includes 1 filter cup (P/N 3150-0942), 4 seal prep flange (P/N 5022-2188), G1361-68710
1260 Infinity LC prep pump 1 filter assembly (P/N 5022-2192), 1 peristaltic pump
For 1120 manual injector systems Includes 1 piston seal, 5 PTFE frits, 1 PEEK rotor seal, and 2 seal cap assemblies G4280-68710
For 1220 manual injector systems Includes piston seals, PTFE frits, rotor seal, and 2 seal cap assemblies G4280-68750
For 1220 automated injector systems Includes piston seals, PTFE frits, rotor seal, 2 seal cap assemblies, needle and needle seat G4280-68770
For 1120 automated injector systems Includes 1 piston seal, 5 PTFE frits, 1 Vespel rotor seal, 1 needle, 1 needle seat, and G4280-68730
2 seal cap assemblies
Extended PM kit Includes 2 piston seals (P/N 5063-6589), PTFE frits, 5/pk (P/N 01018-22707), cartridge 5065-4499
For 1100/1050/1200 pumps active inlet valve (P/N 5062-8562), outlet ball valve (P/N G1312-60067) and 2 pistons
(P/N 5063-6586)
Accessory Kits
1260 Infinity LC binary pump accessory kit Includes 1 tubing assembly (P/N 5063-6527), 1 CAN cable (P/N 5181-1519), 1 RRLC G1312-68755
system configurator, 1 stainless steel capillary, 400 x 0.17 mm (P/N G1312-87303),
1 stainless steel capillary, 700 x 0.17 mm (P/N G1312-87304)
1100/1200 pump accessory kit Includes 3 wrenches, 5 PTFE frits, tubing, capillary and wrist strap G1311-68705
Pump configuration kit for G1312B with Includes side cover with fixed rail, top and right cover for pump housing, and 6 connecting G1312-68726
G1158B 2 position/6 port valve capillaries. Allows automatic switching between different delay volumes to optimize the
system for 2.1 mm id or 4.6 mm id columns
Capillary pump accessory kit Includes purge valve and holder, hex keys 2.5 and 3 mm, 2 wrenches 1/2 in x 1/16 in, G1376-68705
wrenches 1/4 in x 5/16 in and 14 mm, wrist strap, torque adaptor and stainless steel frit,
0.5 µm
Accessory kit prep pump/gradient G1361A Includes stainless steel connecting capillaries, solvent mixer, 2 L solvent bottle, bottle head G1361-68707
assembly, filter, glass stop valve, stainless steel union, tubing and other parts
Online degasser accessory kit Includes 8 screws, 8 bushings, 4 markers, tubing, syringe and syringe adapter G1322-68705
Extended flow range kit, 100 µL/min Includes all parts to go from 20 µL/min to 100 µL/min flow rate in a capillary LC system G1376-68707
Manual prep injection valve kit, stainless steel Includes position sensing, 10 mL loop, 25 mL syringe, ring mounting bracket, start cable 5065-9922
and SS connecting capillaries, 0.5 mm id, 40 cm and 60 cm
60
AgileNt PArts AND suPPlies
Autosampler Supplies
Your Agilent autosampler is designed to deliver accurate measurements, precise injection volumes,
and high-quality data. And by following a regular schedule of preventive maintenance, you can ensure
a lifetime of defensible results.
injection Valves
rotor seal
Valve use With Part No. rheBuild Kit Material rotor seal stator stator Face
2 position/6 port injection valve, 400 bar G1313A, 0101-0921 0101-1257 Vespel 0100-1853 0100-1850 0100-1851
G1329A, Tefzel 0100-1849
G1367A/B, 1120
PEEK 0100-2231
2 position/6 port micro injection valve, G1377A, G1389A 0101-1050 Vespel 0100-2088 0100-2089
400 bar
2 position/6 port injection valve, 600 bar G1329B, G1367C 0101-1422 PEEK 0101-1416 0101-1417
SL, G1367D SL
Plus, G1367E,
1220 Infinity LC
10 port, dual loop valve, 400 bar G2258A 0101-1385 Vespel 0101-2415 0101-1390
2 position/6 port MBB injection valve, G2260A 0101-1267 0101-1268 PEEK 0101-1268* 0100-2195
400 bar
2 position/6 port ultra high pressure G4226A 5067-4114 Vespel 5068-0007 5068-0006
valve, 1200 bar
*Includes seal and stator face
Injection Valve Assembly, 0101-0921 Stator for 2 position/6 port injection valve, Stator for 2 position/6 port ultra high pressure
600 bar, 0101-1417 valve, 1200 bar, 5068-0006
WWW.AgileNt.CoM/CheM/lC 61
AgileNt PArts AND suPPlies
(Continued)
Seat Assembly 0.17 mm id standard autosampler, G1329-87017 Seat Assembly 0.12 mm id standard autosampler, G1329-87012
62
AgileNt PArts AND suPPlies
Accessories
Description use With Part No.
Seat adapter G1313A, G1329A, G1389A, G2260A, G1313-43204
1120 and 1220 Infinity LC
Finger caps, for Autosampler Gripper, 15/pk G1313A, G1329A, G1389A, G2260A, 5063-6506
1120 and 1220 Infinity LC
Tool for micro seat capillary mounting G1377A G1377-44900
Needle seat, PEEK 600 bar, with seat capillary, Seat assembly for 1290/1260 Infinity LC, Needle Assembly for 1290/1260 Infinity LC,
G1367-87012 G4226-87012 G4226-87201
WWW.AgileNt.CoM/CheM/lC 63
AgileNt PArts AND suPPlies
loop Capillaries
Description Agilent Autosampler Part No.
Stainless steel loop capillary, 100 µL G5667A G5667-60320
G1313A 01078-87302
G1329A/B
1120
1220 Infinity LC
G1367A/B/C G1367-87300
Piston seals, 5063-6589
G4226A 5067-4710
G1367E
Stainless steel loop capillary, 900 µL G1329A/B G1313-87303
G2260A
Loop capillary, 40 µL G1367D G1377-87310
G4226A 5067-4703
G1367E
Sample loop, 01078-87302 G1377A G1377-87300
G1389A G1329-87302
Loop capillary, 20 µL G4226A G4226-60310
G1367E
Loop capillary, 8 µL G1389A G1375-87303
G1377A G1375-87315
Loop capillary, 20 µL, G4226-60310
Loop capillary, 5 mL G2260A G2260-68711
64
AgileNt PArts AND suPPlies
Autosampler trays
Autosampler trays
Description Part No.
For g1313A, g1329A/B, 1120, 1220 infinity lC samplers
100 position tray for 2 mL vials G1313-44510
Vial plate, G2255-68700
100 position tray for 2 mL vials, thermostattable G1329-60011
40 position tray for 2 mL vials G1313-44512
15 position tray for 6 mL vials G1313-44513
External vial tray for 17 vials (disposal position) G1313-60004
Disposal tube for external vial tray G1313-27302
For g1367A/B/C/D/e, g2258A, g4226A
Well plate tray, 2 well plates, 10 vials (supports 50 mm plates) G2258-60011
Vial plate for 54 x 2 mL vials, 6/pk G2255-68700
Vial plate for 15 x 6 mL vials 5022-6539 Vial plate, 5022-6539
For g1367A/B/C/D/e
100 position tray for micro vials G4226-60021
Also for G4226A
Plate for 27 Eppendorf Safe-lock tubes, 0.5/1.5/2 mL 5022-6538
For g2257A
8.5 in well plate rack, 2/pk G2255-68709
For 16 shallow well plates, 4 deep well plates (max 48 mm height) or 6 vial racks
10 in well plate rack, 2/pk G2255-68710
For 20 shallow well plates (max height 16 mm), not compatible with deep well plates
Plate for 27 Eppendorf Safe-lock tubes, 5022-6538
8.5 in well plate rack extension G2255-68720
Includes 3 racks for 3 x 16 shallow well plates, 2 x 4 deep well plates (max 48 mm height)
or 3 x 6 vial racks
10 in well plate rack extension G2255-68730
Includes 3 racks for 3 x 20 shallow well plates (max height 16 mm), not compatible with
deep well plates
For g2250A
205H rack, two 96-deep well plates G2250-04504
200 rack, 13 x 100 mm tubes (9 mL), 96 G2250-04503
207 rack, 16 x 100 mm tubes (12 mL), 75 G2250-04502
209 rack, 12 x 32 mm tubes (12 mL), 96 G2250-04501
94A special holding 1100 tray G2250-04500
WWW.AgileNt.CoM/CheM/lC 65
AgileNt PArts AND suPPlies
Autosampler Kits
Autosampler Kits
Description Kit Contents Part No.
Preventive Maintenance Kits
For G1329B autosamplers Includes 1 PEEK rotor seal, 1 needle seat, 1 needle G1313-68719
For G1313A, G1329A autosamplers Includes 1 Vespel rotor seal, 1 needle seat, 1 needle, 2 metering seals and 15 finger caps G1313-68709
For G1313A, G1329A samplers Includes 1 Vespel rotor seal, 1 needle seat, 1 needle G1313-68730
For G1367A/B autosamplers Includes 1 Vespel rotor seal, 1 needle seat, 1 needle, 1 peristaltic pump cartridge, G1367-68730
1 seal tight nut
For G1367C/D autosamplers Includes 1 needle assembly, 1 low carry over seat, 1 peristaltic pump, 1 rotor seal G1367-68734
For G1367E autosampler Includes 1 PEEK rotor seal, 1 needle seat, 1 needle, 1 peristaltic pump cartridge, G1367-68741
1 metering seal
For 1220 manual injector systems Includes piston seals, PTFE frits, gold seals and rotor seal G4280-68750
For 1220 automated injector systems Includes piston seals, PTFE frits, gold seals, rotor seal, needle and needle seat G4280-68770
For 1120 manual injector systems Includes 1 piston seal, 5 PTFE frits, 2 gold seals, 4 outlet caps and 1 PEEK rotor seal G4280-68710
For 1120 automated injector systems Includes 1 piston seal, 5 PTFE frits, 2 gold seals, 4 outlet caps, 1 Vespel rotor seal, G4280-68730
1 needle and 1 needle seat
For G4226A HiP autosampler Includes 1 needle seat, 1 needle, 1 rotor 2 position/6 ports, 1 peristaltic pump, G4226-68735
1 metering seal
Extended PM kit Includes 1 Vespel rotor seal, 1 needle seat, 1 needle, 1 metering seal, 1 stator face 5065-4498
For G1313A, G1329A autosamplers
(Continued)
66
AgileNt PArts AND suPPlies
Autosampler Kits
Description Kit Contents Part No.
Door replacement Kits
Cabinet upgrade kit Includes side panel, top cover and front door G1329-68736
for 1260 Infinity LC sampler
Cabinet kit for G1367E and G4226A Includes side panel, base plate and top cover 5067-4662
Door replacement kit Includes front and side doors G1329-68737
for 1260 Infinity LC sampler
Door repair kit for G1367E and G4226A Includes front door G4226-67001
Light protection kit for G1329A Includes opaque front and side doors and front cover G1329-68718
Door replacement kit for G1329A Includes transparent front and side doors G1329-68727
upgrade Kits
Multidraw upgrade kit for Includes 500 µL capillary, 1500 µL capillary and ZDV union G1313-68711
G1313A/G1327A/G1329A autosamplers
Large volume injection kit for the 80 µL seat capillary G4216-68711
Agilent 1290 Infinity autosampler G4226A
WWW.AgileNt.CoM/CheM/lC 67
AgileNt PArts AND suPPlies
68
AgileNt PArts AND suPPlies
WWW.AgileNt.CoM/CheM/lC 69
AgileNt PArts AND suPPlies
70
AgileNt PArts AND suPPlies
WWW.AgileNt.CoM/CheM/lC 71
AgileNt PArts AND suPPlies
Valve Supplies
Agilent's industry-leading Manual Injection Valves are designed to ensure trouble-free operation with your
HPLC System.
Our valves also feature patented "Make-Before-Break" architecture that allows you to switch between
Injection Valve Assembly, 0101-0921 LOAD and INJECT positions without interrupting the flow. So you can analyze more samples in less time.
• PEEK offers a high chemical resistance and versatility, and will tolerate the entire pH range
from 0 to 14
• Tefzel is recommended for use in applications where PEEK cannot be used, such as methylene chloride
or DMSO in higher concentrations
Vespel
PEEK
Tefzel
72
AgileNt PArts AND suPPlies
injection Valves
injection Valves
rotor seal
Valve use With Part No. rheBuild Kit Material rotor seal stator stator Face
2 position/6 port injection valve, 400 bar G1313A, 0101-0921 0101-1257 Vespel 0100-1853 0100-1850 0100-1851
G1329A, Tefzel 0100-1849
G1367A/B, 1120
PEEK 0100-2231
2 position/6 port micro injection valve, G1377A, G1389A 0101-1050 Vespel 0100-2088 0100-2089
400 bar
2 position/6 port injection valve, 600 bar G1329B, G1367C 0101-1422 PEEK 0101-1416 0101-1417
SL, G1367D SL
Plus, G1367E,
1220 Infinity LC
10 port, dual loop valve, 400 bar G2258A 0101-1385 Vespel 0101-2415 0101-1390
2 position/6 port MBB injection valve, G2260A 0101-1267 0101-1268 PEEK 0101-1268* 0100-2195
400 bar
2 position/6 port ultra high pressure G4226A 5067-4114 Vespel 5068-0007 5068-0006
valve, 1200 bar
*Includes seal and stator face
WWW.AgileNt.CoM/CheM/lC 73
AgileNt PArts AND suPPlies
74
AgileNt PArts AND suPPlies
Valve head, 2 position/6 port, 600 bar, 5067-4137 2 position/6 port ultra high pressure valve, Valve head, 2 position/10 ports for ultra high
5067-4117 pressure, 1200 bar, 5067-4118
Stator for 2 position/6 port ultra high pressure Rotar seal, 2 position/6 port, 600 bar for C1316B,
valve, 600 bar, 0101-1417 0101-1409
WWW.AgileNt.CoM/CheM/lC 75
AgileNt PArts AND suPPlies
• A 20 µL loop (installed). Loops are also available in stainless steel or PEEK from 5 µL to 5 mL
(10 mL for PEEK)
• Make-Before-Break (MBB) technology allows switching without flow interruption
• Wide 30° port angles offer easier access to fittings
• Built-in position sensing switch provides the chromatograph with a reproducible start signal
• Versatile ports accommodate 1/8 in (3.2 mm) and 1/16 in (1.6 mm) od tubing.
7725i manual injection valve, 5063-6502
Note: 1/16 in od tubing requires an adapter, P/N 5067-1503
• 1.0 mm diameter passages allow flow rates up to 800 mL/min with virtually no pressure drop
• Make-Before-Break technology allows switching without flow interruption
• High reproducibility for both partial-filling and complete-filling methods
• Sample range is 100 µL to 20 mL (10 mL loop is installed)
• Flow range is 10 to 800 mL/min
• Built-in position sensing switch gives the chromatograph a reproducible start signal
76
AgileNt PArts AND suPPlies
WWW.AgileNt.CoM/CheM/lC 77
AgileNt PArts AND suPPlies
• Stainless steel loops are square cut and free of burrs for a flush connection
• Flexible PEEK loops have a clean, straight cut for low dead volume connections
78
AgileNt PArts AND suPPlies
WWW.AgileNt.CoM/CheM/lC 79
AgileNt PArts AND suPPlies
80
AgileNt PArts AND suPPlies
WWW.AgileNt.CoM/CheM/lC 81
AgileNt PArts AND suPPlies
Thermostatted Column
Compartment Supplies
thermostatted Column Compartment supplies
High temperature heat exchanger, G1316-80002 Description Part No.
Capillary system for 0.12 mm id use G1316-68744
Rapid Resolution High Throughput capillary kit 5065-9947
Used for converting an Agilent 1200 instrument to the RRLC configuration, to enable use
of high efficiency columns (to 600 bar). Can also be used for Agilent 1100 instruments.
1200 capillary kit for 0.12 mm id G1316-68716
High temperature heat exchanger, 1.6 µL, 0.12 mm id, "R" G1316-80002
High temperature heat exchanger, 1.6 µL, 0.12 mm id, "L" G1316-80003
Heat exchanger/cooler, 1.5 µL, 0.12 mm id G1316-80004
High temperature heat exchanger, G1316-80003 Carrier for heat exchanger 1290 Infinity TCC and 1200 Series TCC SL G1316-83200
Column Identification Module (CIM), 3/pk 5062-8588
Column clamp, 6/pk 5063-6526
Column holder for micro LC columns 5001-3702
Column connecting capillary with fittings, 7 cm, 0.12 mm id, 1/16 in male/male G1316-87303
Column connecting capillary with fittings, 9 cm, 0.17 mm id, 1/16 in male/male G1316-87300
Column connecting capillary with fittings, 18 cm, 0.12 mm id, 1/16 in male/male G1313-87304
Column connecting capillary with fittings, 18 cm, 0.17 mm id, 1/16 in male/male G1313-87305
PEEK tubing, 1/32 in od, 0.4 mm id, 450 mm, Micro valve to waste 5022-6503
Heat exchanger/cooler, G1316-80004
Thermal column insulation enclosure kit G1316-60001
82
AgileNt PArts AND suPPlies
WWW.AgileNt.CoM/CheM/lC 83
AgileNt PArts AND suPPlies
(Continued)
84
AgileNt PArts AND suPPlies
(Continued)
WWW.AgileNt.CoM/CheM/lC 85
AgileNt PArts AND suPPlies
(Continued)
86
AgileNt PArts AND suPPlies
(Continued)
WWW.AgileNt.CoM/CheM/lC 87
AgileNt PArts AND suPPlies
88
AgileNt PArts AND suPPlies
Detector Supplies
Agilent wavelength detectors combine exceptional flexibility with superior instrument control, data
communication, and analytical capabilities. This section shows you how to maintain your detector’s high
level of selectivity and sensitivity.
WWW.AgileNt.CoM/CheM/lC 89
AgileNt PArts AND suPPlies
Certified lamps
• All lamps are tested for noise and drift specifications, correct operating voltage, light intensity
and proper alignment
• Improved coating process increases Agilent lamp lifetimes up to 50%
Deuterium lamp, G1314-60100
• Agilent deuterium lamps are designed with a much narrower aperture providing increased light
intensity and decreased noise – translating into an appreciably higher signal-to-noise ratio
• By providing higher sensitivity, Agilent lamps can extend detection capabilities and improve
qualification at trace levels – for more than 2,000 hours of use
Agilent's lamps are manufactured in an ISO 9001 certified environment and are fully traceable throughout
every step of the production process. Each lamp is then tested to ensure it meets Agilent's performance
specifications. Test equipment is regularly calibrated using optical standards certified by NIST
Long life HiS Deuterium lamp, 5190-0917 (National Institute of Standards and Technology) or PTB (Physikalisch-Technische Bundesanstalt).
Detector lamps
Description Comments Part No.
Variable Wavelength Detector (VWD)
Long life Deuterium lamp with RFID tag For G1314D/E/F G1314-60101
Long life Deuterium lamp For G1314A/B/C, 1120 and 1220 Infinity G1314-60100
Deuterium longlife lamp, 2140-0813 LC
Diode Array Detector (DAD)/Multiple Wavelength Detector (MWD)
Long life HiS Deuterium lamp (8-pin) with For G4212A/B 5190-0917
RFID tag
Long life Deuterium lamp with RFID tag For G1315C/D and G1365C/D 2140-0820
Long life Deuterium lamp For G1315A/B and G1365A/B 2140-0813
Long life Deuterium lamp For G1315A/B and G1365A/B 5182-1530
Deuterium lamp For G1315A/B and G1365A/B 2140-0590*
Tungsten lamp For G1315A/B/C/D and G1365A/B/C/D G1103-60001
*Standard lamp for 1000 hours of use only
90
AgileNt PArts AND suPPlies
typical Column length (cm) typical Peak Width recommended Flow Cell
<=5 0.025 Micro Flow Cell High Pressure
10 0.05 0.05-0.2 mL/min Semi-micro Flow Cell Flow Cell For
Pressure
20 0.1 Standard Flow Cell
Above 100 bar
> = 40 0.2
Typical Flow Rate 0.05-0.2 mL/min 0.2-0.4 mL/min 0.4-0.8 mL/min 1-2 mL/min 0.05-5 mL/min
Internal Column Diameter 1.0 mm 2.1 mm 3.0 mm 4.6 mm
WWW.AgileNt.CoM/CheM/lC 91
AgileNt PArts AND suPPlies
92
AgileNt PArts AND suPPlies
typical Column length (cm) typical Peak Width recommended Flow Cell
<=5 0.025 80/500 nL Flow Cell High Pressure
10 0.05 Semimicro Flow Cell Flow Cell
20 0.1 Standard Flow Cell
> = 40 0.2
Typical Flow Rate 0.05-0.2 mL/min 0.2-0.4 mL/min 0.4-0.8 mL/min 1-2 mL/min 0.05-5 mL/min
Internal Column Diameter 0.3-1 mm 2.1 mm 3.0 mm 4.6 mm
WWW.AgileNt.CoM/CheM/lC 93
AgileNt PArts AND suPPlies
Max-Light cartridge cell, interior view, 60 mm path Max-Light HDR flow cell, interior view,
for high concentrations, G4212-60007 to show short 3.7 mm path length
for high concentrations, G4212-60032
94
AgileNt PArts AND suPPlies
WWW.AgileNt.CoM/CheM/lC 95
AgileNt PArts AND suPPlies
96
AgileNt PArts AND suPPlies
WWW.AgileNt.CoM/CheM/lC 97
AgileNt PArts AND suPPlies
other Detectors
98
AgileNt PArts AND suPPlies
WWW.AgileNt.CoM/CheM/lC 99
AgileNt PArts AND suPPlies
100
AgileNt PArts AND suPPlies
Bio-inert supplies
Agilent 1260 Infinity
Bio-inert Quaternary LC Supplies
For your challenging bio-molecule analyses, the new 1260 Infinity Bio-inert Quaternary LC System sets
new standards in performance, reliability, and robustness. Analysis of proteins and biotherapeutics usually
presents the most challenging solvent conditions for any LC instrument. In addition, bio-molecules tend to
bind unspecifically to surfaces, requiring tedious procedures. To address these needs, Agilent designed this
application-specific LC instrument for bio-molecular analysis – without any compromise in performance –
built on the proven Agilent 1200 Infinity platform technology.
The Agilent 1260 Infinity Bio-inert Quaternary LC features bio-inertness for all components without
exception. The sample flow path through autosampler, capillaries and a variety of detectors are completely
metal-free, with only PEEK and ceramic components coming into contact with your bio-molecule. Thus, the
uncertainty of secondary interaction for proteins and peptides with surfaces which can result in peak tailing,
low recovery and decreased column lifetime is minimized – and your confidence maximized.
(Continued)
WWW.AgileNt.CoM/CheM/lC 101
AgileNt PArts AND suPPlies
102
AgileNt PArts AND suPPlies
LC/MS Supplies
Combined with Agilent's industry-leading LC systems, our single quadrupole, ion trap, triple
quadrupole, TOF and Q-TOF LC/MS solutions combine world-class performance with legendary
reliability and ease-of-use.
This section contains all of the mass spectrometry supplies you need to keep your LC mass
spectrometer running at peak performance.
WWW.AgileNt.CoM/CheM/lC 103
AgileNt PArts AND suPPlies
Save ordering time and money with the LC/MS PM Kit! It contains the common supplies specified in Agilent service engineer preventive maintenance
procedure for LC/MS platforms.
104
AgileNt PArts AND suPPlies
lC/Ms supplies
6100 series 6400 series
single 6300 series triple 6500 series
Quadrupole 6200 series ion trap Quadrupole Accurate-Mass
Description lC/Ms toF lC/Ms lC/Ms lC/Ms Q-toF lC/Ms Part No.
ES nebulizer assembly, original 3 3 3 3 3 G1946-60098
ES nebulizer needle (original) replacement kit 3 3 3 3 3 G2427A
ES nebulizer assembly, new 3 3 3 3 3 G1958-60098
ES nebulizer needle (new) replacement kit 3 3 3 3 3 G1958-60136
APCI nebulizer assembly 3 3 3 3 3 G1946-60037
APCI nebulizer needle replacement kit 3 3 3 3 3 G2428A
Needle assembly APCI/Multimode 3 3 3 3 G1947-60103
Corona needle APCI/Multimode 3 3 3 3 3 G1947-20029
Capillary cap, high temperature, 3.0 mm 3 3 3 3 3 G1946-20301
Capillary, 0.5 mm id, dielectric* 3 3 G1946-80009
Capillary, 0.6 mm id, dielectric* 3 3 3 3 3 59987-20040
Capillary, 0.6 mm id, resistive, fast polarity switching* 3 G1960-80060
Spring, canted coil, 0.25 in id, 0.53 mm 3 3 3 3 3 1460-2571
1/6 in tee, low dead volume, stainless steel 3 3 0100-0969
*Dielectric capillary supports standard polarity switching only. Resistive capillary supports fast polarity switching.
(Continued)
WWW.AgileNt.CoM/CheM/lC 105
AgileNt PArts AND suPPlies
lC/Ms supplies
6100 series 6400 series
single 6300 series triple 6500 series
Quadrupole 6200 series ion trap Quadrupole Accurate-Mass
Description lC/Ms toF lC/Ms lC/Ms lC/Ms Q-toF lC/Ms Part No.
Syringe adapter 3 9301-1291
Syringe pump 3 3162-0178
1/16 in finger-tight PEEK fitting 3 3 3 0100-1516
Female luer to female 10/32 adapter 3 3 3 0100-2304
PEEK tubing 3 3 3 0890-1915
Gas-tight syringe, PTFE Luer lock 3 3 3 5182-9710
High-throughput skimmer, 2 mm 3 3 3 G1969-20302
Skimmer 1 (G1956A/B) 3 G1956-20302
HED assembly 3 G1946-80019
HED assembly (G6140A, G6460A, G6530A) 3 G2571-80103
HED assembly 3 G1956-80000
Electron multiplier replacement horn 3 3 3 05971-80103
Replacement horn and dynode 3 3 3 G2441-80010
106
AgileNt PArts AND suPPlies
lC/Ms Chemicals
6100 series 6400 series
single 6300 series triple 6500 series
Quadrupole 6200 series ion trap Quadropole Accurate-Mass
Description lC/Ms toF lC/Ms lC/Ms lC/Ms Q-toF lC/Ms Part No.
ES/APCI positive ion performance standard,
5 x 1 mL ampoules 3 3 3 3 G2423A
WWW.AgileNt.CoM/CheM/lC 107
AgileNt PArts AND suPPlies
108
AgileNt PArts AND suPPlies
Quiet Cover
Agilent has a solution to the frequent maintenance of LC/MS and ICP-MS rough pumps (visual check of oil
levels, oil changes, oil additions, clean-up of oil leaks, etc.), as well as the inherent noise produced by the
pumps. Quiet Covers are designed for easy movement, maintenance, and better living with rough pumps
used with Agilent and other LC/MS systems.
Quiet Cover
Description Compatible Pump Models Part No. Quiet Cover DS, G6012A
Quiet Cover BOC Edwards Pumps, E2M28, E2M18, or E1M18 G3199B
Quiet Cover MS Agilent MS40+ G6011A
Quiet Cover DS Agilent DS202, DS302, DS402, and DS602 G6012A
Quiet Cover TS Agilent TS300, TS300INV, TS600, TS600INV, and TS800 G6013A
Quiet Cover GC/MS* Agilent DS42, Pfeiffer Duo 2.5 G6014A
*This model does not contain all features.
WWW.AgileNt.CoM/CheM/lC 109
AgileNt PArts AND suPPlies
110
AgileNt PArts AND suPPlies
2No autotune
4Calibration only
WWW.AgileNt.CoM/CheM/lC 111
CrossLAb PArts And suPPLies
AgilentCrossLaboffersagrowingportfolioofHPLCsuppliesmanufacturedforseamlessperformance
CrossLab withavarietyofnon-Agilentanalyticalinstrumentsinyourlab.Lookinsidethisselectionguidetofind
awiderangeofproductsforyourapplications.
Wecurrentlysupport:
• Waters
• Shimadzu
Agilent
• Dionex*
• CTCAnalytics
• Andmoretocome
Ourgrowingportfolioincludesthefollowingproducts:
• Autosamplersyringes
• Capillaries,tubing,andfittings
• Detectorlamps
• PerformanceMaintenancekits
• Pumpsupplies
• Sampleloops
• Valvesupplies
• Vialsandclosures
• Wellplatesandsealingmats
AgilentCrossLabismorethansupplies:
• Over40yearsofchromatographyexpertise
• Therightsuppliesforbothroutineandchallengingapplications
• Hassle-freeoperationsandreproducibleresults
• High-qualityproductsmanufacturedtoAgilentstandards
• Technicalandapplicationsupport
• Dependableworldwideavailabilityanddelivery
• Convenienceofconsolidatingpurchasing
• 90-dayriskfreemoneybackguarantee
*DionexisnowapartofThermoScientific
Agilent CrossLab works with WATERS SHIMADZU THERMO SCIENTIFIC AND MORE
112
CrossLAb PArts And suPPLies
• ManufacturedinanISO9001certifiedenvironment
• Quartzglassbulbsforextendedlifetime
• Individuallytestedforlightintensity,noiseanddrift,correctoperatingvoltage,andproperalignment
forlowlamp-to-lampvariability
• TightQA/QCwithtraceabilityforeachlampthroughouteverystepoftheproductprocess
• Bothdeuteriumlampsandtungstenlampsavailable
deuterium lamps
• Highoutputstabilityandintensityforextendeddetectioncapabilitiesandimprovedqualification
attracelevel
tiPs & tooLs
• Guaranteedlifetimeof2,000hours
Eachtimeafterareplacementof
tungsten lamps adetectorlamp,itisrecommended
toperformawavelengthcalibrationtest
• Offercoverageinthevisiblewavelengthrangeforhighsensitivitydetection andanintensitytestafterwarmup.
• Averagelifetimerangefrom1,200to5,000hoursdependingonoperationconditions
suchasoperationcycles,softstart,andoperationvoltage
www.AgiLent.Com/Chem/CrossLAbhPLC 113
CrossLAb PArts And suPPLies
• ManufacturedinanISO9001certifiedfacility
• MadefromFirstHydrolyticType1ClassAorClassBborosilicateglass,whichconformstoUSFDA,
USP,andEUPharmacopeiastandards
• Protectedbyproprietarypackagingwithacrushbarriertoreducevialbreakage
Snaptopvialswithwrite-onspot,8010-0025
• Packagedinmaterialthathasbeentestedandselectedforcleanliness
• Subjectedtorigorousend-of-linesamplingandqualitycontrolprocedurestoensureallvialsremain
withinspecifications
• Compatiblewithawidevarietyofautosamplersregardlessofmakeandmodel
For Agilent CrossLab Vials and Closures ordering information please see
the General Chromatography catalog (publication # 5991-1059EN)
www.agilent.com/chem/library
AgilentnowoffersafulllineofpHmetersandelectrodes.Designedforchromatographers,
thesepHmetersofferintuitiveuserdesignandexceptionalruggednessforyourlab.
Learnmoreatwww.agilent.com/chem/phmeters
114
CrossLAb PArts And suPPLies
Advantages of Agilent CrossLab well plates: Advantages of Agilent CrossLab sealing mats:
• Madefrompolypropylene • Protectwellcontentsduringstorage
• FreefromRNase,DNase,Endotoxins,andhumanDNA • FreefromRNase,DNase,Endotoxins,andhumanDNA
• Chemicallyresistanttocommonsolvents • Highlyflexibleforatightsealandexactfit
• Autoclavable(121°C/20min) • Insetsineverywelleliminatetheneedforglueduringconnection
• Alpha-numericgrid • Pierceablewithpipettetips(0.5mLand1.0mLsealingmats)
• Compatiblewithpipettingworkstationsandmulti-channelpipettes • Preventsolventevaporation
• Raisedrimsareavailablewith0.5mLand1.0mLdeepwellplates • Madefromthermoplasticelastomer(TPE)orethylene-vinylacetate(EVA)
forefficientsealingandareducedriskofcross-contamination • Compatiblewithcommonsolvents
duringrigorousvortexing
• Availablein96-or384-wellplateformat
• 96-wellplatesrangefrom0.2mLto2mL
• 384-wellplatesavailablein0.1mLand0.25mL
• Stackable
For Agilent CrossLab Well Plates and Sealing Mats ordering information please see
the General Chromatography catalog (publication # 5991-1059EN)
www.agilent.com/chem/library
Cleanliness of well plates and sealing mats: Agilent CrossLab vs. the competition
BlankincompetitorA1.0mL96-wellplate
20000000
BlankincompetitorB1.0mL96-wellplatewithmatchingsealingmat
TotalIonCurrent(TIC)
15000000
BlankinAgilentCrossLab1.0mL96-wellplatewithmatchingsealingmat Thechemicalextractionexperimentsdemonstratethesuperior
10000000 cleanlinessoftheAgilentCrossLabwellplatesandsealingmats
comparedtothecompetition,makingthemidealforLC/MSapplications.
Reagentblank
5000000
Systemblank
0
0 1 2 3 4 5 6 7 8 9 min
LC/MSESIpositivechromatogramcomparison.Reagentblank:1:1Acetonitrile/H2Owith0.1%formicacid
www.AgiLent.Com/Chem/CrossLAbhPLC 115
CrossLAb PArts And suPPLies
• Accuracytowithin±1%ofnominalvolumewithaprecisionof1%at80%ofthetotalvolume
• Achemicallyinertfluidpathofstainlesssteel,borosilicateTypeIglass,orPTFE
• Robustdesignforlonglifetime
116
CrossLAb PArts And suPPLies
Syringeterminationsattheendofthesyringebarrelfunctionastheinterfacebetweenthesyringeanditsmatingconnectionsuchastheneedle.
Terminationsareofferedinanumberofdifferentneedleandconnectionconfigurationstoaccommodateabroadrangeofapplications.
Fixed needle
• Economicaloptionforinjections
• Preferredforapplicationsrequiringtracelevelsamples
• Needleiscementedintotheglasssyringebarrelatapointcorrespondingtothezerograduationmark
• Deadvolumeislimitedtotheneedle’sinternalvolume
• Notautoclavable
• Recommendedforusewhereprobabilityofneedlebendingisminimal
removable needle
• Versatileoptionforinjections
• Needleseatspreciselyatthezerograduationmark
• Needlecanbereplacedifdamagedorclogged
• Allowsforaremovableneedlewithoutincreasingdeadvolume
• Idealforwhenthereisariskofneedleclogging
• Autoclavablewhendisassembled(repeatedautoclavingshortenssyringelife)
Chem
• ¼-28UNFmalefittingthreadconnection
• Usedforlow-volumeapplicationswheresystemdeadvolumemustbeminimized
• Canbescreweddirectlyintoinjectionvalves
www.AgiLent.Com/Chem/CrossLAbhPLC 117
CrossLAb PArts And suPPLies
note: MostmanualHPLCinjectionvalvesaredesigned
tobeusedwitha22-gauge,ora22s-gauge
NeedleGauge22 NeedlePointStyle3 bluntneedlepointstyle3.
118
CrossLAb PArts And suPPLies
www.AgiLent.Com/Chem/CrossLAbhPLC 119
CrossLAb PArts And suPPLies
120
CrossLAb PArts And suPPLies
www.AgiLent.Com/Chem/CrossLAbhPLC 121
CrossLAb PArts And suPPLies
Plungers:
• Availableinsapphireorceramic
Facesealsreplacementkit,8005-0536 • Sapphireplungersaremadefromhighpuritymonocrystallinesapphireforoptimalconcentricity
andresistancetowear
• Aremeticulouslycutandpolishedforgreatdurabilityandlonglife
Seals:
tiPs & tooLs
• Manufacturedfromultra-high-molecular-weightpolyethylene(UHMWPE)orgraphite-filled
Plungers(orpistons)shouldbe polytetrafluoroethylene(GFP)
exchangedonaregularbasis • Designedtoprovideprecisesealingaroundtheplungers
incombinationwithsealstomaintain • Engineeredtodelivertopperformanceoverhighlydynamicflowandpressureranges
thebestsealingsurfaceanddurability
foroptimalinstrumentperformance.
122
CrossLAb PArts And suPPLies
AgilentCrossLabcheckvalvesandassemblycomponents:
• Madetooperateatdifferentpressures(upto16,000psi,or1,100bar)perspecificationsfrom
theOriginalEquipmentManufacturers(OEMs)
• Madefromavarietyofmaterials,suchasstainlesssteel,titanium,ceramic,andPEEK,
dependingonOEMspecifications
• Carefullyassembledtoensurereliabilityandconsistentperformance
• Eachrubyorceramicballandsapphireorceramicseatismanufacturedunderextremelytight
tolerancestoensurepropersealingwithintheoperatingpressurerange
www.AgiLent.Com/Chem/CrossLAbhPLC 123
CrossLAb PArts And suPPLies
124
CrossLAb PArts And suPPLies
• Replacethesolventinletfrits
www.AgiLent.Com/Chem/CrossLAbhPLC 125
CrossLAb PArts And suPPLies
126
CrossLAb PArts And suPPLies
rotor seals:
Avarietyofmaterialsforawiderangeofapplications
Arotorsealisapolymericdiskthatcreatesahigh-pressuresealagainstthestatororstatorfaceseal.
Avarietyofmaterialsareavailablefordifferentapplications.Itisimportanttoreplacerotorsealsona
routinebasistopreventexcessivewear.Therecommendedreplacementintervalformostrotorseals Rotor,6-portvalve,8001-0601
isonceperyearforpreventivemaintenanceorasneededdependingonstressesimposedby
specificapplications.
• Vespel:Vespelisapolyimidewithlowwearandhighchemicalresistance.Recommendedforuse
withsolutionsunderpH10;becausemorebasicsolutionsdissolveVespelovertimeanddamage
therotorseal
• PEEK(Polyetheretherketone):PEEKoffershighresistance,versatility,andapplicabilityfortheentire
pHrangebetween0and14
• Tefzel:RecommendedforuseinapplicationswherePEEKcannotbeused,suchashigher
concentrationsofmethylenechlorideordimethylsulfoxide(DMSO)
PEEKrotorsealsareincompatiblewith
concentratednitricandsulfuricacids.
www.AgiLent.Com/Chem/CrossLAbhPLC 127
CrossLAb PArts And suPPLies
stators
• Availablein316stainlesssteel,PEEK,andceramicdependingonthespecificationsofOEMs
• Typicallyrequirereplacementonlyiftheportsorsealingsurfacesbecomedamaged,which
canbepreventedbyusingproperinjectionneedles.
Stator,6-portvalve,8001-0604
sample Loops
Stainless Steel Sample Loops:
• Haveburr-freeandsquare-cutendstoensureaflushconnectiontovalveports
• Actualvolumesmightdifferduetotoleranceofmetaltubingbore
• Accuracyoflargemetalloops(1.0mm,0.040inbore)is±14%,intermediateloops
(0.5mm,0.020inbore)is±21%,andsmallloops(0.2mm,0.007inbore)is±65%
128
CrossLAb PArts And suPPLies
atpeakperformance
Manyinstrumentfailuresarecausednotbyfunctionalbreakdowns,butbyalackofperformance
maintenance.Assuggestedbyarecentstudy,aregularperformancemaintenanceprogramcanreduce
instrumentfailureratesupto25%,andiscriticaltoensureoptimaloverallsystemoperations.
2960/2965PMkit,8005-0915
up to 25% reduction
in failures
Failures
Improvedperformance
maintenanceregime
Failure
implementedonsite
Time
AgilentCrossLabPMkitscontainthenormalwearparts,toolsfordisassembly/reassembly,
andinstructionsnecessarytokeepyoursystemsoperatingatpeakperformance.Thekitsprovide
aconvenient,cost-effectivewaytomakesureyourinstrumentsareproperlymaintained.Eachkit
containsallthepartsyouneedto:
• Boostsystemefficiencyandreliability
• Reduceunplanneddowntimeandrepaircosts
• Increaseaccuracybyenhancingprecisionandsensitivity
• Complywithregulatoryrequirements,ormeetqualityaccreditationstandards
• Extendinstrumentusefullife
• Eliminateindividualpartordering
• PMkitsavailableforpumps,valves,autosamplers,andHPLCsystems
www.AgiLent.Com/Chem/CrossLAbhPLC 129
CrossLAb PArts And suPPLies
PeeK tubing
• Flexibleandeasytocuttodesiredlengths
• Idealforfrequentlychangedconnections
• Resistsmechanicalandsolventdamage,evenathightemperatures
• Biocompatibleandinerttoalmostallorganicsolvents
• Adurablealternativetostainlesssteelconnections
• AcceptsbothstainlesssteelandPEEKfittings
130
CrossLAb PArts And suPPLies
CrossLab Fittings
TherightLCfittingsmakethebestLCconnections
Toensureleak-freeconnections,andtopreventthelossofpeakshapeandresolution,alwaysusethe
recommendedfittingstyleforcolumns,valvesandunions.
WithAgilentCrossLabfittings,yougettheconfidenceandchoicethatcomewith:
• Robustdesignforlonglifeandsmooth,leak-freeoperation
• Stainlesssteelnutsandferrulesforhigh-pressuresystems
• Polymerfittingsforbiocompatibleapplications
www.AgiLent.Com/Chem/CrossLAbhPLC 131
CrossLAb PArts And suPPLies
• In-linesolventfilters,installedbetweentheLCpumpandinjector,preventblockagesbyremoving
particlesfromsolventsbeforetheyreachtheinjector
• Columninletfilters,positionedimmediatelybeforeanLCcolumn,removeparticlesfromboththe
injectionsystemandsample
132
CrossLAb PArts And suPPLies
hPLC troubleshooting
(Continued)
www.AgiLent.Com/Chem/CrossLAbhPLC 133
CrossLAb PArts And suPPLies
hPLC troubleshooting
(Continued)
134
CrossLAb PArts And suPPLies
hPLC troubleshooting
(Continued)
www.AgiLent.Com/Chem/CrossLAbhPLC 135
CrossLAb PArts And suPPLies
hPLC troubleshooting
136
CrossLAb PArts And suPPLies
Thecrossreferencestotheoriginalequipmentmanufacturer(OEM)partnumberslistedhereserveasarecommendationthattheAgilentCrossLab (Continued)
productsareviablealternativestoOEMproducts.CrossLabproductsarecompatiblewiththecorrespondingOEMinstruments,althoughinsome
cases,theCrossLabproductsmayhaveslightlydifferentdesignsascomparedtotheOEMcounterparts.AllCrossLabsuppliesarebackedby
Agilent's90-daymoney-backwarranty.
www.AgiLent.Com/Chem/CrossLAbhPLC 137
CrossLAb PArts And suPPLies
CrossLabSuppliesforWatersHPLCSystems
Thecrossreferencestotheoriginalequipmentmanufacturer(OEM)partnumberslistedhereserveasarecommendationthattheAgilentCrossLabproductsareviablealternatives
toOEMproducts.CrossLabproductsarecompatiblewiththecorrespondingOEMinstruments,althoughinsomecases,theCrossLabproductsmayhaveslightlydifferentdesignsas
comparedtotheOEMcounterparts.AllCrossLabsuppliesarebackedbyAgilent's90-daymoney-backwarranty.
Autosamplersyringe,gastight,8005-0417
138
CrossLAb PArts And suPPLies
CrossLabSuppliesforWatersHPLCSystems
Pump supplies
similar to Agilent
oem CrossLab
model description unit Part no. Part no.
Plungers and seals
2690SeparationsModule Sapphireplungerassembly,standard 1/pk WAT270959 8005-0538
2690DDissolutionSeparationsModule
2695SeparationsModule
2695DDissolutionSeparationsModule
2790SeparationsModule
2795SeparationsModule
2796BioseparationsModule
2690SeparationsModule Plungerseals,clear 2/pk 700001326 8005-0514
2690DDissolutionSeparationsModule
2695SeparationsModule
2695DDissolutionSeparationsModule
2690SeparationsModule Plungersealreplacementkit,standard,yellow 2/pk WAT270938 8005-0535
2690DDissolutionSeparationsModule
2695SeparationsModule
2695DDissolutionSeparationsModule
2790SeparationsModule
2795SeparationsModule
AllianceGPC/V2000Systems
2690SeparationsModule Plungersealreplacementkit,black 2/pk WAT271066 8005-0541
2690DDissolutionSeparationsModule
2695SeparationsModule
2695DDissolutionSeparationsModule
2790SeparationsModule
2795SeparationsModule
2690SeparationsModule Facesealsreplacementkit 4/pk WAT270939 8005-0536
2690DDissolutionSeparationsModule
2695SeparationsModule
2695DDissolution
SeparationsModule
2790SeparationsModule
2795SeparationsModule
AllianceGPC/V2000Systems
Thecrossreferencestotheoriginalequipmentmanufacturer(OEM)partnumberslistedhereserveasarecommendationthattheAgilentCrossLab (Continued)
productsareviablealternativestoOEMproducts.CrossLabproductsarecompatiblewiththecorrespondingOEMinstruments,althoughinsome
cases,theCrossLabproductsmayhaveslightlydifferentdesignsascomparedtotheOEMcounterparts.AllCrossLabsuppliesarebackedby
Agilent's90-daymoney-backwarranty.
www.AgiLent.Com/Chem/CrossLAbhPLC 139
CrossLAb PArts And suPPLies
CrossLabSuppliesforWatersHPLCSystems
Pump supplies
similar to Agilent
oem CrossLab
model description unit Part no. Part no.
Plungers and seals
2690SeparationsModule Sealwashfacesealkit 1/pk WAT271017 8005-0539
2690DDissolutionSeparationsModule
2695SeparationsModule
2695DDissolutionSeparationsModule
2790SeparationsModule
2795SeparationsModule
AllianceGPC/V2000Systems
2796BioseparationsModule Sealwash,plungerseal 4/pk 700002258 8005-0516
2796BioseparationsModule Plungerseal,standard 2/pk 700002257 8005-0515
2690SeparationsModule Sealwashplungersealreplacementkit 2/pk WAT271018 8005-0540
2690DDissolutionSeparationsModule
2695SeparationsModule
2695DDissolutionSeparationsModule
2790SeparationsModule
2795SeparationsModule
AllianceGPC/V2000Systems
510HPLCPump Sapphireplunger 1/pk WAT025656 8005-0527
600MultiSolventDeliverySystem Orientedsapphireplunger 1/pk WAT069511 8005-0533
610PowerLineIsocraticPump
LCModule1
510HPLCPump Plungerseal,graphite-filledPTFE(GFP),black 1/pk WAT026613 8005-0529
515HPLCPump
600MultiSolventDeliverySystem
LCModule1
510HPLCPump Plungerseal,black,225µL 1/pk WAT026644 8005-0530
515HPLCPump
600MultiSolventDeliverySystem
610PowerLineIsocraticPump
LCModule1
616LCSystem Sapphireplunger 1/pk WAT031788 8005-0531
626LCSystem
1515HPLCPump Sapphireplungerassembly 1/pk WAS207069 8005-0523
1525HPLCPump
515HPLCPump
Thecrossreferencestotheoriginalequipmentmanufacturer(OEM)partnumberslistedhere (Continued)
serveasarecommendationthattheAgilentCrossLabproductsareviablealternativestoOEM
products.CrossLabproductsarecompatiblewiththecorrespondingOEMinstruments,
althoughinsomecases,theCrossLabproductsmayhaveslightlydifferentdesignsas
comparedtotheOEMcounterparts.AllCrossLabsuppliesarebackedbyAgilent's90-day
money-backwarranty.
Sealwashfacesealkit,
8005-0539
140
CrossLAb PArts And suPPLies
CrossLabSuppliesforWatersHPLCSystems
Pump supplies
similar to Agilent
oem CrossLab
model description unit Part no. Part no.
Plungers and seals
1515HPLCPump Plungerseal,clear 1/pk WAT022934 8005-0524
1525HPLCPump Plungerseal,clear 4/pk WAT022946 8005-0525
510HPLCPump
515HPLCPump
600MultiSolventDeliverySystem
610PowerLineIsocraticPump
LCModule1
Check Valves and Cartridges
2690SeparationsModule Checkvalvecartridgereplacementkit 2/pk WAT270941 8005-0537
2690DDissolutionSeparationsModule
2695SeparationsModule
2695DDissolutionSeparationsModule
2790SeparationsModule
2795SeparationsModule
AllianceGPC/V2000Systems
626LCSystem Checkvalvecartridge 1/pk WAT024120 8005-0526
1515HPLCPump Checkvalvecartridge 2/pk 700000254 8005-0513
1525HPLCPump
2695SeparationsModule
2695DDissolutionSeparationsModule
2795SeparationsModule
510HPLCPump
515HPLCPump
600MultiSolventDeliverySystem
610PowerLineIsocraticPump
LCModule1
1525HPLCPump Checkvalvecartridge 1/pk 700002399 8005-0508
2695SeparationsModule
2695DDissolutionSeparationsModule
2795SeparationsModule
515HPLCPump
600MultiSolventDeliverySystem
Thecrossreferencestotheoriginalequipmentmanufacturer(OEM)partnumberslistedhereserveasarecommendationthattheAgilentCrossLab (Continued)
productsareviablealternativestoOEMproducts.CrossLabproductsarecompatiblewiththecorrespondingOEMinstruments,althoughinsome
cases,theCrossLabproductsmayhaveslightlydifferentdesignsascomparedtotheOEMcounterparts.AllCrossLabsuppliesarebackedby
Agilent's90-daymoney-backwarranty.
www.AgiLent.Com/Chem/CrossLAbhPLC 141
CrossLAb PArts And suPPLies
CrossLabSuppliesforWatersHPLCSystems
Pump supplies
similar to Agilent
oem CrossLab
model description unit Part no. Part no.
Check Valves and Cartridges
1515HPLCPump Cartridgecheckvalvesystem 2/pk 700000253 8005-0512
1525HPLCPump
515HPLCPump
600MultiSolventDeliverySystem
LCModule1
510HPLCPump Outletcheckvalverebuildkit,225µL 2/pk WAT026014 8005-0528
515HPLCPump
600MultiSolventDeliverySystem
610PowerLineIsocraticPump
LCModule1
detector supplies
similar to Agilent
oem CrossLab
model description unit Part no. Part no.
2996PhotodiodeArrayDetector Cellgasket 2/pk WAT057924 8005-0532
996PhotodiodeArrayDetector
Thecrossreferencestotheoriginalequipmentmanufacturer(OEM)partnumberslistedhereserveasarecommendationthattheAgilentCrossLab (Continued)
productsareviablealternativestoOEMproducts.CrossLabproductsarecompatiblewiththecorrespondingOEMinstruments,althoughinsome
cases,theCrossLabproductsmayhaveslightlydifferentdesignsascomparedtotheOEMcounterparts.AllCrossLabsuppliesarebackedby
Agilent's90-daymoney-backwarranty.
142
CrossLAb PArts And suPPLies
CrossLabSuppliesforWatersHPLCSystems
Thecrossreferencestotheoriginalequipmentmanufacturer(OEM)partnumberslistedhereserveasarecommendationthattheAgilentCrossLabproductsareviablealternatives
toOEMproducts.CrossLabproductsarecompatiblewiththecorrespondingOEMinstruments,althoughinsomecases,theCrossLabproductsmayhaveslightlydifferentdesignsas
comparedtotheOEMcounterparts.AllCrossLabsuppliesarebackedbyAgilent's90-daymoney-backwarranty.
www.AgiLent.Com/Chem/CrossLAbhPLC 143
CrossLAb PArts And suPPLies
CrossLabSuppliesforWatersHPLCSystems
Thecrossreferencestotheoriginalequipmentmanufacturer(OEM)partnumberslistedhereserveasarecommendationthattheAgilentCrossLab (Continued)
productsareviablealternativestoOEMproducts.CrossLabproductsarecompatiblewiththecorrespondingOEMinstruments,althoughinsome
cases,theCrossLabproductsmayhaveslightlydifferentdesignsascomparedtotheOEMcounterparts.AllCrossLabsuppliesarebackedby
Agilent's90-daymoney-backwarranty.
2960/2965PMkit,8005-0915 515pumpPMkit,8005-0913
144
CrossLAb PArts And suPPLies
CrossLabSuppliesforWatersHPLCSystems
Thecrossreferencestotheoriginalequipmentmanufacturer(OEM)partnumberslistedhereserveasarecommendationthattheAgilentCrossLab (Continued)
productsareviablealternativestoOEMproducts.CrossLabproductsarecompatiblewiththecorrespondingOEMinstruments,althoughinsome
cases,theCrossLabproductsmayhaveslightlydifferentdesignsascomparedtotheOEMcounterparts.AllCrossLabsuppliesarebackedby
Agilent's90-daymoney-backwarranty.
www.AgiLent.Com/Chem/CrossLAbhPLC 145
CrossLAb PArts And suPPLies
CrossLabSuppliesforWatersHPLCSystems
Thecrossreferencestotheoriginalequipmentmanufacturer(OEM)partnumberslistedhereserveasarecommendationthattheAgilentCrossLab (Continued)
productsareviablealternativestoOEMproducts.CrossLabproductsarecompatiblewiththecorrespondingOEMinstruments,althoughinsome
cases,theCrossLabproductsmayhaveslightlydifferentdesignsascomparedtotheOEMcounterparts.AllCrossLabsuppliesarebackedby
Agilent's90-daymoney-backwarranty.
Rheodyne7725(i)PMkit,8005-0904
146
CrossLAb PArts And suPPLies
CrossLabSuppliesforWatersHPLCSystems
Thecrossreferencestotheoriginalequipmentmanufacturer(OEM)partnumberslistedhereserveasarecommendationthattheAgilentCrossLabproductsareviablealternatives
toOEMproducts.CrossLabproductsarecompatiblewiththecorrespondingOEMinstruments,althoughinsomecases,theCrossLabproductsmayhaveslightlydifferentdesigns
ascomparedtotheOEMcounterparts.AllCrossLabsuppliesarebackedbyAgilent's90-daymoney-backwarranty.
Rheodyne9125PMkit,8005-0906
www.AgiLent.Com/Chem/CrossLAbhPLC 147
CrossLAb PArts And suPPLies
CrossLabSuppliesforWatersHPLCSystems
Thecrossreferencestotheoriginalequipmentmanufacturer(OEM)partnumberslistedhereserveasarecommendationthattheAgilentCrossLabproductsareviablealternativesto
OEMproducts.CrossLabproductsarecompatiblewiththecorrespondingOEMinstruments,althoughinsomecases,theCrossLabproductsmayhaveslightlydifferentdesignsas
comparedtotheOEMcounterparts.AllCrossLabsuppliesarebackedbyAgilent's90-daymoney-backwarranty.
148
CrossLAb PArts And suPPLies
CrossLabSuppliesforWatersHPLCSystems
Thecrossreferencestotheoriginalequipmentmanufacturer(OEM)partnumberslistedhereserveasarecommendationthattheAgilentCrossLabproductsareviablealternativesto
OEMproducts.CrossLabproductsarecompatiblewiththecorrespondingOEMinstruments,althoughinsomecases,theCrossLabproductsmayhaveslightlydifferentdesignsas
comparedtotheOEMcounterparts.AllCrossLabsuppliesarebackedbyAgilent's90-daymoney-backwarranty.
Please visit www.agilent.com/chem/CrossLabhPLC for up-to-date info for the growing portfolio
of CrossLab LC Supplies for your non-Agilent HPLC systems.
For Agilent CrossLab Vials and Closures ordering information please see
the General Chromatography catalog (publication # 5991-1059EN)
www.agilent.com/chem/library
For Agilent CrossLab Well Plates and Sealing Mats ordering information
please see the General Chromatography catalog (publication # 5991-1059EN)
www.agilent.com/chem/library
www.AgiLent.Com/Chem/CrossLAbhPLC 149
CrossLAb PArts And suPPLies
Long-lifedeuteriumlamp,8001-0704
Thecrossreferencestotheoriginalequipmentmanufacturer(OEM)partnumberslistedhereserveasarecommendationthattheAgilentCrossLabproductsareviablealternativesto
OEMproducts.CrossLabproductsarecompatiblewiththecorrespondingOEMinstruments,althoughinsomecases,theCrossLabproductsmayhaveslightlydifferentdesignsas
comparedtotheOEMcounterparts.AllCrossLabsuppliesarebackedbyAgilent's90-daymoney-backwarranty.
Autosamplersyringe,8001-0401 Replacementsyringeplunger,500µL,8001-0403
150
CrossLAb PArts And suPPLies
CrossLabSuppliesforShimadzuHPLCSystems
Thecrossreferencestotheoriginalequipmentmanufacturer(OEM)partnumberslisted (Continued)
hereserveasarecommendationthattheAgilentCrossLabproductsareviablealternatives
toOEMproducts.CrossLabproductsarecompatiblewiththecorrespondingOEM
instruments,althoughinsomecases,theCrossLabproductsmayhaveslightlydifferent
designsascomparedtotheOEMcounterparts.AllCrossLabsuppliesarebacked
byAgilent's90-daymoney-backwarranty.
www.AgiLent.Com/Chem/CrossLAbhPLC 151
CrossLAb PArts And suPPLies
CrossLabSuppliesforShimadzuHPLCSystems
Thecrossreferencestotheoriginalequipmentmanufacturer(OEM)partnumberslistedhereserveasarecommendationthat
theAgilentCrossLabproductsareviablealternativestoOEMproducts.CrossLabproductsarecompatiblewiththe
correspondingOEMinstruments,althoughinsomecases,theCrossLabproductsmayhaveslightlydifferentdesignsas
comparedtotheOEMcounterparts.AllCrossLabsuppliesarebackedbyAgilent's90-daymoney-backwarranty.
152
CrossLAb PArts And suPPLies
CrossLabSuppliesforShimadzuHPLCSystems
Thecrossreferencestotheoriginalequipmentmanufacturer(OEM)partnumberslistedhereserveasarecommendation
thattheAgilentCrossLabproductsareviablealternativestoOEMproducts.CrossLabproductsarecompatiblewiththe
correspondingOEMinstruments,althoughinsomecases,theCrossLabproductsmayhaveslightlydifferentdesignsas
comparedtotheOEMcounterparts.AllCrossLabsuppliesarebackedbyAgilent's90-daymoney-backwarranty.
www.AgiLent.Com/Chem/CrossLAbhPLC 153
CrossLAb PArts And suPPLies
CrossLabSuppliesforShimadzuHPLCSystems
Thecrossreferencestotheoriginalequipmentmanufacturer(OEM)partnumberslistedhereserveasarecommendationthattheAgilentCrossLabproductsareviablealternativesto
OEMproducts.CrossLabproductsarecompatiblewiththecorrespondingOEMinstruments,althoughinsomecases,theCrossLabproductsmayhaveslightlydifferentdesignsas
comparedtotheOEMcounterparts.AllCrossLabsuppliesarebackedbyAgilent's90-daymoney-backwarranty.
154
CrossLAb PArts And suPPLies
CrossLabSuppliesforShimadzuHPLCSystems
tubing
similar to Agilent
od id Length oem CrossLab
model description (mm) (mm) (mm) Fittings Part no. Part no.
LC-2010 ETFEtubingforusebetweentheinletblock 1.6 0.8 3000 Nofittings 228-18495-01 8001-0807
LC-20AD andthecheckvalve
LC-2010 FEPtubing 3 1.5 3000 Nofittings 670-10321-05 8001-0823
SIl-20A/AC
SPD-20A/AV PEEKtubing 1.6 0.25 500 Nofittings 670-10324-01 8001-0824
SPD-M20A 228-33376-50
Thecrossreferencestotheoriginalequipmentmanufacturer(OEM)partnumberslistedhereserveasarecommendationthattheAgilentCrossLabproductsareviablealternatives
toOEMproducts.CrossLabproductsarecompatiblewiththecorrespondingOEMinstruments,althoughinsomecases,theCrossLabproductsmayhaveslightlydifferentdesignsas
comparedtotheOEMcounterparts.AllCrossLabsuppliesarebackedbyAgilent's90-daymoney-backwarranty.
www.AgiLent.Com/Chem/CrossLAbhPLC 155
CrossLAb PArts And suPPLies
CrossLabSuppliesforShimadzuHPLCSystems
Thecrossreferencestotheoriginalequipmentmanufacturer(OEM)partnumberslistedhereserveasarecommendation
thattheAgilentCrossLabproductsareviablealternativestoOEMproducts.CrossLabproductsarecompatiblewiththe
correspondingOEMinstruments,althoughinsomecases,theCrossLabproductsmayhaveslightlydifferentdesignsas
comparedtotheOEMcounterparts.AllCrossLabsuppliesarebackedbyAgilent's90-daymoney-backwarranty.
Please visit www.agilent.com/chem/CrossLabhPLC for up-to-date info for the growing portfolio of
CrossLab LC Supplies for your non-Agilent HPLC systems.
For Agilent CrossLab Vials and Closures ordering information please see
the General Chromatography catalog (publication # 5991-1059EN)
www.agilent.com/chem/library
For Agilent CrossLab Well Plates and Sealing Mats ordering information please see
the General Chromatography catalog (publication # 5991-1059EN)
www.agilent.com/chem/library
156
CrossLAb PArts And suPPLies
Thecrossreferencestotheoriginalequipmentmanufacturer(OEM)partnumberslistedhereserveasarecommendationthattheAgilentCrossLabproductsareviablealternatives
toOEMproducts.CrossLabproductsarecompatiblewiththecorrespondingOEMinstruments,althoughinsomecases,theCrossLabproductsmayhaveslightlydifferentdesignsas
comparedtotheOEMcounterparts.AllCrossLabsuppliesarebackedbyAgilent's90-daymoney-backwarranty.
Chem(1/4-28UNFscrewthreads),gastight, Removableneedle,gastight,8002-0401
8002-0405
www.AgiLent.Com/Chem/CrossLAbhPLC 157
CrossLAb PArts And suPPLies
CrossLabSuppliesforDionexHPLCSystems
Autosampler supplies
similar to
od id Length Volume oem
model material (mm) (mm) (mm) (µL) Fittings Part no. Part no.
needle seat Capillaries, 1/pk
WPS-3000SL Stainlesssteel 0.8 0.12 120 1.35 Withfittings, 6820.2407 8002-0808
nonpre-swaged
WPS-3000SL Stainlesssteel 0.8 0.18 120 3.1 Withfittings, 6820.2408 8002-0809
nonpre-swaged
WPS-3000SLSemiprep Stainlesssteel 0.8 0.5 120 24 Withfittings, 6820.2409 8002-0810
nonpre-swaged
Pump supplies
similar to Agilent
oem CrossLab
model description unit Part no. Part no.
Pistons and seals
ISO-3100A Piston,sapphire 1/pk 6035.2240 8002-0515
LPG-3400A
LPG-3400AB
LPG-3400M
LPG-3400MB
DGP-3600A
DGP-3600AB
DGP-3600M
DGP-3600MB
HPG-3x00A
HPG-3x00M
ISO-3100SD Pistonseal,reversed-phase 2/pk 6040.0304 8002-0502
LPG-3400SD
LPG-3400RS
DGP-3400SD
DGP-3600RS
HPG-3x00SD
HPG-3x00RS
ISO-3100SD Supportringforpistonsseals 2/pk 6040.0012 8002-0501
LPG-3400SD
LPG-3400RS
DGP-3400SD
DGP-3600RS
HPG-3x00SD
HPG-3x00RS
UltiMate3000pumpseries Ringseal,DR-8,PTFE 10/pk 2266.0082 8002-0601
Thecrossreferencestotheoriginalequipmentmanufacturer(OEM)partnumberslistedhereserveasarecommendationthattheAgilentCrossLab (Continued)
productsareviablealternativestoOEMproducts.CrossLabproductsarecompatiblewiththecorrespondingOEMinstruments,althoughinsome
cases,theCrossLabproductsmayhaveslightlydifferentdesignsascomparedtotheOEMcounterparts.AllCrossLabsuppliesarebackedby
Agilent's90-daymoney-backwarranty.
158
CrossLAb PArts And suPPLies
CrossLabSuppliesforDionexHPLCSystems
Pump supplies
similar to Agilent
oem CrossLab
model description unit Part no. Part no.
Check Valves and Cartridges
UltiMate3000RSpumps, Checkvalvecartridge,ceramic 1/pk 6041.2301 8002-0517
optionalforSDandBMpumps
ISO-3100A Checkvalvecartridge,sapphire,biocompatible 1/pk 6035.2300 8002-0516
LPG-3400A
LPG-3400M
LPG-3400MB
LPG-3400AB
DGP-3600A
DGP-3600M
DGP-3600MB
DGP-3600AB
HPG-3x00A
HPG-3x00M
HPG-3200P
Thecrossreferencestotheoriginalequipmentmanufacturer(OEM)partnumberslistedhereserveasarecommendationthattheAgilentCrossLabproductsareviablealternatives
toOEMproducts.CrossLabproductsarecompatiblewiththecorrespondingOEMinstruments,althoughinsomecases,theCrossLabproductsmayhaveslightlydifferentdesignsas
comparedtotheOEMcounterparts.AllCrossLabsuppliesarebackedbyAgilent's90-daymoney-backwarranty.
Vespelrotorseal,8002-0602 Stainlesssteelstator,8002-0603
www.AgiLent.Com/Chem/CrossLAbhPLC 159
CrossLAb PArts And suPPLies
CrossLabSuppliesforDionexHPLCSystems
Thecrossreferencestotheoriginalequipmentmanufacturer(OEM)partnumberslistedhereserveasarecommendation
thattheAgilentCrossLabproductsareviablealternativestoOEMproducts.CrossLabproductsarecompatiblewiththe
correspondingOEMinstruments,althoughinsomecases,theCrossLabproductsmayhaveslightlydifferentdesignsas
comparedtotheOEMcounterparts.AllCrossLabsuppliesarebackedbyAgilent's90-daymoney-backwarranty.
160
CrossLAb PArts And suPPLies
CrossLabSuppliesforDionexHPLCSystems
Thecrossreferencestotheoriginalequipmentmanufacturer(OEM)partnumberslistedhereserveasarecommendationthattheAgilentCrossLab (Continued)
productsareviablealternativestoOEMproducts.CrossLabproductsarecompatiblewiththecorrespondingOEMinstruments,althoughinsome
cases,theCrossLabproductsmayhaveslightlydifferentdesignsascomparedtotheOEMcounterparts.AllCrossLabsuppliesarebackedby
Agilent's90-daymoney-backwarranty.
www.AgiLent.Com/Chem/CrossLAbhPLC 161
CrossLAb PArts And suPPLies
CrossLabSuppliesforDionexHPLCSystems
Thecrossreferencestotheoriginalequipmentmanufacturer(OEM)partnumberslistedhereserveasarecommendationthattheAgilentCrossLab (Continued)
productsareviablealternativestoOEMproducts.CrossLabproductsarecompatiblewiththecorrespondingOEMinstruments,althoughinsome
cases,theCrossLabproductsmayhaveslightlydifferentdesignsascomparedtotheOEMcounterparts.AllCrossLabsuppliesarebackedby
Agilent's90-daymoney-backwarranty.
162
CrossLAb PArts And suPPLies
CrossLabSuppliesforDionexHPLCSystems
Thecrossreferencestotheoriginalequipmentmanufacturer(OEM)partnumberslistedhereserveasarecommendationthattheAgilentCrossLab (Continued)
productsareviablealternativestoOEMproducts.CrossLabproductsarecompatiblewiththecorrespondingOEMinstruments,althoughinsome
cases,theCrossLabproductsmayhaveslightlydifferentdesignsascomparedtotheOEMcounterparts.AllCrossLabsuppliesarebackedby
Agilent's90-daymoney-backwarranty.
www.AgiLent.Com/Chem/CrossLAbhPLC 163
CrossLAb PArts And suPPLies
CrossLabSuppliesforDionexHPLCSystems
Thecrossreferencestotheoriginalequipmentmanufacturer(OEM)partnumberslistedhereserveasarecommendationthattheAgilentCrossLab (Continued)
productsareviablealternativestoOEMproducts.CrossLabproductsarecompatiblewiththecorrespondingOEMinstruments,althoughinsome
cases,theCrossLabproductsmayhaveslightlydifferentdesignsascomparedtotheOEMcounterparts.AllCrossLabsuppliesarebackedby
Agilent's90-daymoney-backwarranty.
164
CrossLAb PArts And suPPLies
CrossLabSuppliesforDionexHPLCSystems
Thecrossreferencestotheoriginalequipmentmanufacturer(OEM)partnumberslistedhereserveasarecommendationthattheAgilentCrossLabproductsareviablealternatives
toOEMproducts.CrossLabproductsarecompatiblewiththecorrespondingOEMinstruments,althoughinsomecases,theCrossLabproductsmayhaveslightlydifferentdesignsas
comparedtotheOEMcounterparts.AllCrossLabsuppliesarebackedbyAgilent's90-daymoney-backwarranty.
www.AgiLent.Com/Chem/CrossLAbhPLC 165
CrossLAb PArts And suPPLies
CrossLabSuppliesforDionexHPLCSystems
Thecrossreferencestotheoriginalequipmentmanufacturer(OEM)partnumberslistedhereserveasarecommendationthattheAgilentCrossLab (Continued)
productsareviablealternativestoOEMproducts.CrossLabproductsarecompatiblewiththecorrespondingOEMinstruments,althoughinsome
cases,theCrossLabproductsmayhaveslightlydifferentdesignsascomparedtotheOEMcounterparts.AllCrossLabsuppliesarebackedby
Agilent's90-daymoney-backwarranty.
166
CrossLAb PArts And suPPLies
CrossLabSuppliesforDionexHPLCSystems
Thecrossreferencestotheoriginalequipmentmanufacturer(OEM)partnumberslistedhereserveasarecommendationthattheAgilentCrossLabproductsareviablealternatives
toOEMproducts.CrossLabproductsarecompatiblewiththecorrespondingOEMinstruments,althoughinsomecases,theCrossLabproductsmayhaveslightlydifferentdesignsas
comparedtotheOEMcounterparts.AllCrossLabsuppliesarebackedbyAgilent's90-daymoney-backwarranty.
www.AgiLent.Com/Chem/CrossLAbhPLC 167
CrossLAb PArts And suPPLies
CrossLabSuppliesforDionexHPLCSystems
tubing
similar to Agilent
oem CrossLab
model description od (mm) id (mm) Length (mm) Fittings Part no. Part no.
LPG-3x00peristalticpump PharMedbiocompatibletubing 3.2 1.6 180 Nofittings 6000.5000 8002-0803
Thecrossreferencestotheoriginalequipmentmanufacturer(OEM)partnumberslistedhereserveasarecommendationthattheAgilentCrossLabproductsareviablealternatives
toOEMproducts.CrossLabproductsarecompatiblewiththecorrespondingOEMinstruments,althoughinsomecases,theCrossLabproductsmayhaveslightlydifferentdesignsas
comparedtotheOEMcounterparts.AllCrossLabsuppliesarebackedbyAgilent's90-daymoney-backwarranty.
Please visit www.agilent.com/chem/CrossLabhPLC for up-to-date info for the growing portfolio of CrossLab LC
Supplies for your non-Agilent HPLC systems.
For Agilent CrossLab Vials and Closures ordering information please see
the General Chromatography catalog (publication # 5991-1059EN)
www.agilent.com/chem/library
For Agilent CrossLab Well Plates and Sealing Mats ordering information please see
the General Chromatography catalog (publication # 5991-1059EN)
www.agilent.com/chem/library
168
CrossLAb PArts And suPPLies
Thecrossreferencestotheoriginalequipmentmanufacturer(OEM)partnumberslistedhereserveasarecommendationthattheAgilentCrossLabproductsareviablealternatives
toOEMproducts.CrossLabproductsarecompatiblewiththecorrespondingOEMinstruments,althoughinsomecases,theCrossLabproductsmayhaveslightlydifferentdesignsas
comparedtotheOEMcounterparts.AllCrossLabsuppliesarebackedbyAgilent's90-daymoney-backwarranty.
www.AgiLent.Com/Chem/CrossLAbhPLC 169
CE and CE/MS
CE and CE/MS
CE Solutions Kits
Agilent continues to introduce new CE solutions kits designed to simplify many of your applications:
• Inorganic anions
• Cations
• Organic acids
• Forensic anions
• µPage
These kits include all you need to begin your CE analyses, including buffers, capillaries, conditioning
solutions, test samples, methods and detailed descriptions. Each kit is designed to take advantage of
the automation of the Agilent CE system to make your time in the laboratory more efficient. All kits are
prepared using the same quality procedures as our buffers and are thoroughly tested and supported.
While the kits have been optimized for use with the Agilent CE system, they may be used with virtually
any commercial or home-built CE system.
170
CE and CE/MS
www.agIlEnt.CoM/ChEM/lC 171
CE and CE/MS
1. Thiosulfate
Ultra pure CE water, 5062-8578 2. Bromide
3. Iodide
4. Chloride
5. Sulfate
6. Nitrite
7. Nitrate
8. Molybdate (VI)
9. Azide
10. Thiocyanate
11. Chlorate
12. Fluoride
172
CE and CE/MS
1. Ammonium
2. Potassium
3. Sodium
4. Calcium
5. Magnesium
Coffee
A Energy drink
B
C
C
Cation standard Cation standard
www.agIlEnt.CoM/ChEM/lC 173
CE and CE/MS
1. Chloride 1. Chloride
11 2. Sulfate 2. Sulfate
3. Oxalate
3 3. Tartarate
10 4. Formate 4. Malate
6 5. Malate 5. Citrate
2 6. Citrate 8 6. Succinate
9 7. Succinate
6 7. Pyruvate
5 7 4 7
1 12 8. Pyruvate 8. Acetate
8 2 5 9
9. Acetate 9. Lactate
3 4 1
10. Lactate
11. Phosphate
12. Pyroglutamate
174
CE and CE/MS
1. Cyanide
2. Chloride
3. Nitrite
4. Nitrate
9 5. Sulfate
10 6. Azide
11 7. Selenate
8 13 8. Carbonate
12
12 67 14
15 9. Fluoride
3 5 10. Arsenate
4
11. Phosphate
12. Glutamate
13. Acetate
14. Arsenite
15. Lactate
www.agIlEnt.CoM/ChEM/lC 175
CE and CE/MS
176
CE and CE/MS
www.agIlEnt.CoM/ChEM/lC 177
CE and CE/MS
CZE of a tryptic digest of recombinant human growth hormone using a standard fused-silica capillary
with 75 µm internal diameter
178
CE and CE/MS
25 µm standard capillary
Analysis of cold medicine ingredients in a standard capillary (25 µm id) and an Agilent Extended Light Path Capillary
www.agIlEnt.CoM/ChEM/lC 179
CE and CE/MS
180
CE and CE/MS
www.agIlEnt.CoM/ChEM/lC 181
CE and CE/MS
Each batch of PVA coated capillaries is rigorously tested by Agilent Technologies and includes a
representative electropherogram to assure quality.
The color coding of the capillary (alignment stopper) and the alignment interfaces allow you to easily
combine the correct interface with the capillary. Capillaries for non-Agilent CE systems have removable
alignment stoppers without color code.
PVA coated capillaries can be used for a variety of applications, including protein analysis at physiological
pH, isoelectric focusing, and small anion analysis without the need for flow-reversal agents in the buffer.
PVA coating is available in standard capillaries, or in Agilent Extended Light Path Capillaries ("bubble" cell
capillaries) for high sensitivity applications. Both capillary types are available in longer lengths for use in
non-Agilent systems.
PVA is also available for use with the High Sensitivity Detection Cell for even further improved HPLC-like
sensitivity. In addition, PVA coated capillaries are offered for CE-MS applications. The capillaries are
provided with a normally positioned detection window to allow tandem UV-Vis and MS detection for
improved sample identification.
182
CE and CE/MS
1. Cytochrome C
2 2. Lysozyme
3. Lactoglobulin A
1
4. Lactoglobulin A
5 PVa coated capillary 5. Lactoglobulin B
4
3
5 1. Benzidine
2. Aniline
1 3. o-Toluidine
2 6
4. p-Cl-Aniline
5. 2-Aminonaphthalene
9
4
7
6. 4,4-Methylene-bis(2-chloroaniline)
3
8 7. 3,3-Dichlorobenzidine
8. 2-Amino-5-azotoluene
9. 2-Methyl-5-nitroaniline
CZE analysis of basic amines using PVA coated capillaries (decomposition products of azo dyes)
Goat
Lamb
www.agIlEnt.CoM/ChEM/lC 183
CE and CE/MS
184
CE and CE/MS
Elimination of EOF also simplifies analysis of anions and organic acids by direct UV detection. Without
EOF reduction, highly mobile ions such as nitrate can migrate in the opposite direction to the slower,
longer chain acids.
The CEP coated capillary is stable from pH 2 to 8. It can be used with borate buffers, offering a
different surface functionality to help alleviate sample adsorption. Each batch of CEP coated capillaries
is rigidly tested by Agilent Technologies and each capillary includes a representative electropherogram
to assure quality.
www.agIlEnt.CoM/ChEM/lC 185
CE and CE/MS
These capillaries are a must-have for cIEF, protein, peptide and carbohydrate separations, as well as
replaceable gel CE applications such as oligonucleotides, DNA fragments, and PCR product separations.
µSIL-DNA capillaries are also coated with an FC polymer but have a 75 µm id to accommodate the
viscosity of entangled polymer solutions. All µSIL capillaries are batch tested to ensure the highest
performance and reproducibility.
186
CE and CE/MS
Analysis of Allelic ladder with µSIL-DNA Analysis of Myoglobin tryptic digest using µSIL-WAX
www.agIlEnt.CoM/ChEM/lC 187
CE and CE/MS
Using the high pressure capabilities of the Agilent CE system, both ends of the CEC capillary can be
pressurized. This process prevents outgassing upon application of high voltage and significantly extends
capillary lifetime.
Use CEC to improve resolution of solutes, which are difficult to resolve by HPLC, for hydrophobic solutes
which cannot be solubilized in MEKC buffers, or for reduced sample and solvent consumption compared
to HPLC.
188
CE and CE/MS
1. Chlorothiazide
2. Hydrochlorothiazide
3. Chlorthalidone
Isocratic conditions I
4. Hydroflumethiazide
5. Bendroflumethiazide
6. Bumetanide
Isocratic conditions II
Buffer: 50 mmol/
Na2HPO4, pH 2.5
2
1. Thiourea
10 2. Methylparaben
34 5 3. Ethylparaben
6 11
4. Propylparaben
1 5. Butylparaben
7 9 6. Pentylparaben
8
7. Naphthalene
8. Biphenyl
12
9. Fluorene
10. Phenanthrene
11. Anthracene
12. Fluoranthene
www.agIlEnt.CoM/ChEM/lC 189
CE and CE/MS
In combination with the capillary cassette, alignment interfaces simplify capillary exchange, protect the
fragile detection window and ensure exact alignment of the window in the detector. Quick-change cassette
allows capillary exchange in less than one minute.
note: The color code of the alignment interface must match the color code of the capillary's built-in
alignment stopper.
alignment Interfaces
Color Corresponding g7100 CE g1600 CE
description Id (µm) Code Capillary Part no. Part no.
Alignment interface for standard 50 Green Green G7100-60210 G1600-60210
capillary 75 Blue Blue G7100-60310 G1600-60310
Alignment interface for standard capillary, 100 Gray Gray
G1600-60310 150 Brown Brown
Alignment interface for Agilent 25 Black Black G7100-60150 G1600-60150
Extended Light Path capillaries 50 Red Red G7100-60230 G1600-60230
75 Yellow Yellow G7100-60330 G1600-60330
CE/MS alignment interface for Blue Blue G7100-60400
360 µm od capillaries, nonmetallic Gray
note: 75, 100 and 150 µm id standard capillaries use the same interface (color blue).
PVA coated 50 and 75 µm id capillary for CE/MS use the same nonmetallic interface with color code blue for use with
standard and extended light path capillaries, and the high sensitivity detector cell.
Capillary cassette
Capillary cassette, G7100-60002 g7100 CE g1600 CE
description Part no. Part no.
Capillary cassette G7100-60002 G1600-60002
note: Only use G7100-60002 cassette in G7100 and G1600-60002 cassette in G1600. Never mix cassettes.
190
CE and CE/MS
The high linear range allows quantification of both <0.1% impurities and the main component in one run.
This is useful for all impurity determinations and is especially useful for determining chiral excess.
The high sensitivity detection cell for the Agilent CE system not only improves detection sensitivity more than
10-fold over standard capillaries, but also extends linearity beyond 2000 mAU and provides unsurpassed
spectral fidelity. These improvements are a result of a proprietary micromachined design which increases
the detection pathlength from 75 µm to 1200 µm while dramatically reducing stray light.
The high sensitivity detection cell has a design comprised of a fused-silica cell body and removable
capillaries. The light path through the cell is made from black fused-silica which significantly minimizes stray
light and defines the aperture for the diode-array spectrometer. In addition, the reflective interior functions
as a "lightpipe," ensuring almost 100% transmission of light which entered the cell. These properties result
in enhanced linearity and unsurpassed spectral fidelity with the diode-array detector.
High Sensitivity Detection Cell
www.agIlEnt.CoM/ChEM/lC 191
CE and CE/MS
75 µm id standard capillary
Agilent high sensitivity detection cell vs. 75 µm standard capillary for the CZE separation of naphthalene sulfonic acids
192
CE and CE/MS
CE/MS accessories
The CE/MS Adapter Kit simplifies coupling the Agilent CE system with MS systems equipped with
an electrospray ionization (ESI) source. Integral to this kit is the CE/MS cassette, which completely
thermostats the capillary until it exits the CE system. The cassette offers multiple capillary paths that vary
the capillary length. A method development configuration uses online diode array detection and MS.
For rapid or routine MS analysis, the detector can be bypassed to decrease the total capillary length and
reduce analysis time. The CE/MS adapter kit can be used with the complete Agilent 6000 Series mass
spectrometers, or virtually any electospray-MS platform.
The CE/MS cassette completely thermostats the capillary until it exits the CE system. Methods
development configuration uses online diode array detection (DAD) and MS. For rapid or routine
MS analysis the DAD can be by-passed to decrease the total capillary length and reduce analysis time.
The CE/MS Sprayer Kit includes the electrospray needle and splitter assembly, which allows the direct
connection of the CE instrument with Agilent and other electrospray MS systems. The CE/MS Sprayer Kit
needs the CE/MS Adapter Kit to fully support CE/MS coupling.
CE with tandem UV-Vis and MS detection allows the analysis of complex mixtures. Analyte mixtures are
separated and the components detected via UV-Vis absorption, allowing preliminary identification based
on peak elution time and UV-Vis spectra, or both, when compared to a standard. Online coupling to
electrospray-ionization mass spectrometry (ESI-MS) then reveals unambiguous information on the solute's
molecular weight, and possibly structure.
www.agIlEnt.CoM/ChEM/lC 193
CE and CE/MS
UV MS-tIC (scan)
194
CE and CE/MS
CE/MS Capillaries
description Color Code Unit Part no.
Bare fused-silica, 50 µm id, 125 cm long Green 2/pk G1600-67311
Bare fused-silica, 50 µm id, 100 cm long Green 2/pk G1600-67312
PVA coated capillary, 50 µm id, 125 cm long Green 1/pk G1600-67219
PVA coated capillary, 50 µm id, 100 cm long Green 1/pk G1600-67220
PVA coated capillary, 75 µm id, 125 cm long Blue 1/pk G1600-67319
www.agIlEnt.CoM/ChEM/lC 195
CE and CE/MS
196
CE and CE/MS
Int. (EmL./Ref)
mAU
150 1
50
3 2 40
30
0 20
200
10
200
Ex [nm]
Em [nm] 0
400 700 2 4 6 8 10 min
The total fluorimetry spectrum of the 50 mM borate buffer CZE analysis of a peptide mixture using pre-made 50 mM
pH 9.2 verifies that the solution is free of fluorescence-active sodium phosphate buffer, pH 2.5
impurities (1 and 2 = Rayleigh stray light of zero and first
order, 3 = Raman stray light).
www.agIlEnt.CoM/ChEM/lC 197
CE and CE/MS
198
CE and CE/MS
Instrument Supplies
description Unit Part no. Electrode O-ring, silicone, 5062-8544
Long life HiS Deuterium lamp (8-pin) with RFID tag 5190-0917
Deuterium lamp 2140-0585
Electrode assembly, standard (for G1600 only) G1600-60007
Electrode assembly, short (for G1600 only) G1600-60033
Electrode assembly, standard (for G7100 only) G7100-60007
Electrode assembly, short (for G7100 only) G7100-60033
Electrode O-ring, silicone 5/pk 5062-8544
Electrolyte bottle, 500 mL 9300-1748
Electrolyte bottle, 100 mL 5042-6478 Electrolyte bottle, 500 mL, 9300-1748
Electrolyte bottle cap 9300-1747
Bottle sealing O-ring 0905-1163
Glass filter, solvent inlet, 20 µm 5041-2168
Filter frit adapter, 3 mm 4/pk 5062-8517
Bottle cap plug G1600-23223
Air filter, 5 µm 3150-0619 Filter frit adapters, 5062-8517
Pre-puncher G1600-67201
Screws for pre-puncher/insulation plate holding 10/pk G1600-62402
www.agIlEnt.CoM/ChEM/lC 199
CE and CE/MS
accessories
description Part no.
CE accessory kit G7100-68705
Includes electrode tool, screwdriver, fuses, air filter, glass frit, vials and caps alignment
interfaces (red and green) standard and 50 µm id capillaries: L 64.5 cm, Standard: L 64.5 cm,
Extended Light Path: L 48.5 cm
Rack for 12 mm, 2 mL vials, holds 50 vials per rack, 5/pk 9301-0722
Vial rack, 9301-0722
CE column cutter 5183-4669
Diamond blade replacement kit for CE column cutter 5183-4670
Capillary tubing cutter, 4/pk 5181-8836
200
CE and CE/MS
Troubleshooting
Basic Capillary Electrophoresis troubleshooting
(Continued)
www.agIlEnt.CoM/ChEM/lC 201
CE and CE/MS
(Continued)
202
CE and CE/MS
www.agIlEnt.CoM/ChEM/lC 203
PRODUCT INDEX
Product Index
Agilent Supplies Gas Purifiers ............................................................108 CE and CE/MS
Instrument Supplies.......................................105-106
Autosamplers Alignment Interface .................................................190
Injection Valves.........................................................61 Maintenance Schedule.........................................103 CE/MS Accessories
Kits..........................................................................66-67 Preventive Maintenance Kit ................................104 Adapter Kit ...............................................................194
Loop Capillaries.........................................................64 Quiet Cover ..............................................................109 Capillaries.................................................................195
Maintenance Schedule ...........................................61 Standards Sprayer Kit................................................................195
Metering Device........................................................64 Analyzer Kit............................................................110 Capillaries
Needles and Needle Seats...............................62-63 Calibrant Mixes.....................................................110 Alignment Interface ...............................................190
Trays.............................................................................65 Kits...........................................................................110 Bulk Fused-Silica ....................................................181
Bio-inert Quaternary Tools...........................................................................108 CEP Coated ..............................................................185
Autosampler ....................................................101-102 Loop Capillaries ...........................................................32 Capillary Cassette...................................................190
Column Compartment ...........................................102 Pumps Capillary Electrochromatography (CEC)........188-189
Detectors ..................................................................102 Cross-linked and Bonded µSIL....................186-187
1290 Infinity LC Pump Supplies ............................51
Fittings.......................................................................102 Extended Light Path
Frits and Adapters ....................................................54
Pumps .......................................................................101 (Bubble Cell) Bare Fused-Silica ..................179-180
Valves ........................................................................102 Inlet Valves.................................................................49
Polyvinyl Alcohol (PVA) Coated..................182-184
Capillaries Kits..........................................................................59-60
Standard Bare Fused-Silica..................................178
1200 and 1100 Prep LC Systems ..........................26 Outlet Valves..............................................................49 Universal Bare Fused-Silica .................................181
1220/1120 Infinity Series LC Systems ................33 Pistons and Seals.....................................................50 Capillary Cassette.....................................................190
1260 Bio-inert LC System.......................................30 Purge Valves ..............................................................48 High Sensitivity Detection Cell......................191-192
1260/1200/1100 Infinity Series LC Systems.....23 Routine Maintenance ..............................................47 Instrument Supplies.................................................199
1290 Infinity Series LC Systems ...........................24 Safety Caps ................................................................55 Solution Kits
1290 Valve Head..................................................25-27 Seal Wash ..................................................................52 Cation ........................................................................173
Loop .............................................................................32 Solvent Filters............................................................54 Forensics ..................................................................175
Miscellaneous .....................................................27-29 Solvent Reservoir......................................................53 Inorganic Anion...............................................171-172
PEEK Coated Fused Silica Capillaries – Organic Acids ..........................................................174
Vacuum Degassers...................................................58
100 µL/min Flow ......................................................32 µPAGE ...............................................................176-177
Rack for LC Systems..................................................14
PEEK Coated Fused Silica Capillaries – Standards & Reagents
20 µL/min Flow.........................................................31 Solvent Filters/Degassers ........................................13
Standards......................................................................15 CZE Buffers for Charged Analytes .....................196
PEEK Coated Fused Silica Capillaries CZE Buffers for Proteins.......................................197
for Nano LC................................................................31 Thermostatted Column Compartment
Capillary Conditioning Solutions.........................196
Chip LC ........................................................................100 Capillary Kits ........................................................83-88
MEKC Buffers for Neutral
Detectors Tools ...............................................................................11 and Charged Analytes...........................................197
80 nL and 500 nL Flow Cell..............................95-96 Troubleshooting.................................................546-549 Plating Bath Analysis Buffer ...............................197
Diode Array Detector (DAD)/ Tubing Ultra Pure CE Water ..............................................196
Multiple Wavelength Detector (MWD)...............93 Accessories................................................................35 µPAGE Buffer Solutions and Oligo Standards...197
Evaporative Light Scattering Detector (ELSD).....98 PEEK.............................................................................34 System Start-up and Test Kits...............................198
Fluorescence Detector (FLD) .................................99 Rigid Capillary Tubing ..............................................35 Troubleshooting.................................................201-203
Lamps ..........................................................................90 Vial Rack .....................................................................200
Unions............................................................................42
Maintenance..............................................................89 Vials and Caps...........................................................199
Valves
Maintenance Kits......................................................97 Window Etching Tool...............................................200
Preparative Flow Cells.............................................96 Injection Valves.........................................................73
Refractive Index Detector (RID) ............................98 Maintenance Notes .................................................72
Variable Wavelength Detector (VWD)...........91-92 Manual Injection Valves Columns for Biomolecule Separations
Fittings and Unions with Position Sensing Switches .....................76-77 Affinity Chromatography
Capillary and Fittings Kits .................................36-39 Sample Loops ......................................................78-79 Agilent Bio-Monolith Protein A ..................434-435
Fittings...................................................................40-41 Switching Valves Multiple Affinity Removal System..............438-440
How to Align Connection Properly.......................45 External Switching Valve......................................74 Multiple Affinity Removal System Starter Kits.....441
How to Prepare Connection...................................44 Internal Switching Valve.......................................75 Protein Fractionation System ..............................437
How to Tighten Correctly........................................43 Syringes for Manual Injection Proteomic Reagents ..............................................442
Fraction Collectors mRP-C18 High-Recovery Protein ................442-443
Fitted Plungers........................................................80
Capillary Kits and Needles .....................................70 Analysis Scale
PTFE-Tipped Plungers............................................81
Collecting Tubes and Trays.....................................69 Capillary and Nano.................................................452
G1364D Micro Fraction Collector..........................71 MicroBore (1.0 mm id)..........................................461
Maintenance Schedule ...........................................68 Applications ZORBAX Bio-SCX Series II...................................458
Well Plate Trays ........................................................69 Citations
In-Line Filters ...............................................................12 BioPharmaceutical ...................................................552 PL-SAX ......................................................................487
LC/MS Chemical/Industrial .................................................580 PL-SCX ......................................................................487
Chemicals.................................................................107 Environmental............................................................583 PLRP-S...............................................................486-487
Cleaning Supplies...................................................108 Food and Consumer Products ...............................594 Poroshell 300...........................................................486
Foreline Pump .........................................................107 Pharmaceutical..........................................................611 ZORBAX 300............................................................485
644
PRODUCT INDEX
WWW.AGILENT.COM/CHEM/LC 645
PART NUMBER INDEX
646
PART NUMBER INDEX
WWW.AGILENT.COM/CHEM/LC 647
PART NUMBER INDEX
648
PART NUMBER INDEX
WWW.AGILENT.COM/CHEM/LC 649
PART NUMBER INDEX
650
PART NUMBER INDEX
823750-911 ...............................229, 246 829975-302 ...............................244, 268 858700-314 ........................................238 863750-906 ........................................372
823750-912 ...............................229, 246 829975-305 ...............................244, 268 858700-902 ...............................238, 268 863953-902 ........................................267
823750-913 ...............................229, 246 829975-306 ...............................244, 268 858700-905 ...............................238, 268 863953-905 ........................................267
823750-914 ...............................229, 246 829975-312 ...............................244, 268 858700-906 ...............................238, 268 863953-906 ........................................267
823975-902 ...............................245, 270 829975-902 ...............................244, 267 858700-912 ...............................238, 268 863953-912 ........................................267
823975-932 ...............................245, 270 829975-905 ...............................244, 267 858700-914 ........................................238 863953-914 ........................................267
824700-902 ...............................244, 269 829975-906 ...............................244, 267 858750-902 ........................................372 863954-302 ........................................267
824700-905 ...............................244, 269 829975-912 ...............................244, 267 858750-906 ........................................372 863954-305 ........................................267
824700-906 ...............................244, 269 829975-914 ...............................244, 267 858750-909 ........................................372 863954-306 ........................................267
824700-912 ...............................244, 269 830668-901 ...............................244, 281 858750-944 .......................372, 374-375 863954-312 ........................................267
824700-914 ...............................244, 269 830975-906 ...............................244, 267 858768-901 ...............................238, 281 863954-314 ........................................267
824975-302 ...............................244, 268 830990-902 ........................................268 859700-302 ...............................238, 268 863967-302 ........................................273
824975-305 ...............................244, 268 830990-906 ........................................268 859700-306 ...............................238, 268 863967-902 ........................................273
824975-306 ...............................244, 268 830990-914 ........................................268 859700-902 ...............................238, 268 863973-902 ...............................210, 372
824975-902 ...............................244, 267 831975-902 ........................................270 859700-905 ...............................238, 268 863973-905 ........................................372
824975-905 ...............................244, 267 831975-906 ........................................270 859700-906 ...............................238, 268 863973-906 ........................................372
824975-906 ...............................244, 267 831975-932 ........................................270 859700-912 ...............................238, 268 863973-909 ........................................372
824975-912 ...............................244, 267 831975-936 ........................................270 859700-914 ........................................238 863974-302 ........................................372
824975-914 ...............................244, 267 832975-902 ........................................267 859768-901 ...............................238, 281 863974-306 ........................................372
825700-902 ...............................245, 270 832975-906 ........................................267 860700-304 ........................................334 863974-309 ........................................372
825700-932 ...............................245, 270 833975-902 ........................................270 860700-704 ........................................334 864668-301 ........................................281
825975-902 ...............................245, 270 833975-906 ........................................270 860700-708 ........................................330 864668-901 ........................................281
825975-932 ...............................245, 270 833975-912 ........................................270 860950-902 ........................................372 865600-902 ........................................269
826700-902 ...............................244, 269 833975-932 ........................................270 860950-905 ........................................372 865600-906 ........................................269
826700-906 ...............................244, 269 833975-936 ........................................270 860950-906 ........................................372 865608-901 ........................................282
826975-302 ...............................244, 268 834975-902 ........................................267 860950-909 ........................................372 865630-902 ...............................372, 463
826975-306 ...............................244, 268 834975-906 ........................................267 860975-902 ........................................268 865630-906 ...............................372, 463
826975-902 ...............................244, 267 835668-901 ........................................281 860975-905 ........................................268 865750-902 ........................................372
826975-906 ...............................244, 267 835975-902 ........................................267 860975-906 ........................................268 865750-906 ........................................372
827668-301 ...............................244, 281 835975-905 ........................................267 860975-909 ........................................268 865973-902 ...............................210, 372
827668-901 ...............................244, 281 835975-906 ........................................267 860975-912 ........................................268 865973-905 ........................................372
827700-901 ...............................244, 329 835975-912 ........................................267 860975-914 ........................................268 865973-906 ........................................372
827700-902 ...............................244, 269 835975-914 ........................................267 861600-902 ........................................269 865973-909 ........................................372
827700-905 ...............................244, 269 840140-901 ............261, 269, 273, 283, 861600-906 ........................................269 8660-0827 ..........................................108
827700-906 ...............................244, 269 329-330, 372, 433 861608-901 ........................................282 866668-901 ........................................281
827700-912 ...............................244, 269 840300-908 ........................................330 861630-902 ...............................372, 463 866735-902 ........................................268
827700-914 ...............................244, 269 843300-908 ........................................330 861700-901 ........................................282 866953-302 ........................................267
827768-901 ...............................244, 282 846952-704 ........................................334 861753-902 ........................................268 866953-902 ........................................267
827975-301 ...............................244, 329 846975-202 ........................................267 861753-905 ........................................268 866953-905 ........................................267
827975-302 ...............................244, 268 846975-902 ........................................267 861753-906 ........................................268 866953-906 ........................................267
827975-305 ...............................244, 268 846975-906 ........................................267 861753-912 ........................................268 866953-912 ........................................267
827975-306 ...............................244, 268 846975-914 ........................................267 861753-914 ........................................268 866953-914 ........................................267
827975-312 ...............................244, 268 8500-1867 ..........................................107 861767-902 ........................................273 866967-902 ........................................273
827975-314 ...............................244, 268 8500-2236 ..........................................107 861768-901 ........................................282 868050-901 ...............................282, 318
827975-901 ........................................244 8500-4410 ..........................................195 861775-902 ........................................372 868100-901 ...............................282, 318
827975-902 ......................244, 267, 329 8500-6762.............................................15 861775-906 ........................................372 868150-901 ...............................282, 318
827975-905 ...............................244, 267 8500-6782 ..........................................196 861953-902 ........................................267 870050-902 ...............................269, 317
827975-906 ...............................244, 267 8500-6785 ..........................................174 861953-905 ........................................267 870050-906 ...............................269, 317
827975-912 ...............................244, 267 8500-6786 ..........................................197 861953-906 ........................................267 870050-914 ...............................269, 317
827975-914 ...............................244, 267 8500-6787 ..........................................197 861953-912 ........................................267 870100-902 ...............................269, 317
828668-301 ...............................244, 281 8500-6797 ..........................................172 861953-914 ........................................267 870100-906 ...............................269, 317
828668-901 ...............................244, 281 8500-6900 ..........................................174 861954-302 ........................................267 870100-914 ...............................269, 317
828700-901 ...............................244, 329 8500-6917 ..........................................110 861954-305 ........................................267 870150-902 ...............................269, 317
828700-902 ...............................244, 269 857700-302 ...............................238, 268 861954-306 ........................................267 870150-906 ...............................269, 317
828700-905 ...............................244, 269 857700-305 ...............................238, 268 861954-309 ........................................267 870150-914 ...............................269, 317
828700-906 ...............................244, 269 857700-306 ...............................238, 268 861954-312 ........................................267 8710-0004 ..........................................108
828700-912 ...............................244, 269 857700-312 ...............................238, 268 861954-314 ........................................267 8710-0510....................................99, 108
828700-914 ...............................244, 269 857700-314 ........................................238 861967-302 ........................................273 8710-0806 ..........................................108
828768-901 ...............................244, 282 857700-902 ...............................238, 268 861967-902 ........................................273 8710-1534.............................................95
828975-301 ...............................244, 329 857700-905 ...............................238, 268 861971-901 ........................................281 8710-1615 ..........................................108
828975-302 ...............................244, 268 857700-906 ...............................238, 268 861973-306 ........................................372 8710-1622 ..........................................108
828975-305 ...............................244, 268 857700-912 ...............................238, 268 861973-902 ........................................372 8710-1924......................................11, 48
828975-306 ...............................244, 268 857700-914 ........................................238 861973-906 ........................................372 8710-1930 ......................11, 35, 58, 108
828975-309 ........................................268 857750-902 ........................................372 863600-902 ........................................269 8710-1931......................................11, 35
828975-312 ...............................244, 268 857750-906 ........................................372 863600-905 ........................................269 8710-2699 ..........................................108
828975-314 ...............................244, 268 857750-909 ........................................372 863600-906 ........................................269 871700-902 ........................................268
828975-901 ...............................244, 329 857750-944 ...............................372, 375 863608-901 ........................................282 871700-906 ........................................268
828975-902 ...............................244, 267 857768-901 ...............................238, 281 863630-902 ...............................372, 463 871700-914 ........................................268
828975-905 ...............................244, 267 858700-302 ...............................238, 268 863630-906 ...............................372, 463 872700-902 ........................................268
828975-906 ...............................244, 267 858700-305 ...............................238, 268 863668-301 ........................................281 872700-906 ........................................268
828975-912 ...............................244, 267 858700-306 ...............................238, 268 863668-901 ........................................281 873700-902 ........................................270
828975-914 ...............................244, 267 858700-312 ........................................268 863700-901 ........................................282 873700-906 ........................................270
WWW.AGILENT.COM/CHEM/LC 651
PART NUMBER INDEX
873700-932 ........................................270 880995-206 ........................................372 895150-909 ......................317, 373, 466 933975-902 ........................................262
873700-936 ........................................270 880995-209 ........................................372 897150-102 ......................317, 373, 466 933975-906 ........................................262
874700-902 ........................................268 880995-902 ........................................372 897150-106 ......................317, 373, 466 933975-932 ........................................262
874700-906 ........................................268 880995-905 ........................................372 897150-109 ......................317, 373, 466 933975-936 ........................................262
875700-902 ........................................270 880995-906 ........................................372 897250-102 ......................317, 373, 466 934967-902 ........................................260
875700-906 ........................................270 880995-909 ........................................372 897250-105 ......................317, 373, 466 934967-906 ........................................260
875700-932 ........................................270 881750-902 ........................................372 897250-106 ......................317, 373, 466 935967-902 ........................................260
875700-936 ........................................270 883668-301 ........................................281 897250-109 ......................317, 373, 466 935967-906 ........................................260
877150-102 ...............................269, 317 883668-901 ........................................281 921700-902 ...............................245, 263 935967-912 ........................................260
877150-106 ...............................269, 317 883700-704 ........................................334 921700-932 ...............................245, 263 946975-902 ........................................260
877150-114 ...............................269, 317 883700-714 ........................................334 921975-902 ...............................245, 263 946975-906 ........................................260
877250-101 ...............................318, 329 883700-901 ........................................329 921975-932 ...............................245, 263 959701-902 ........................................253
877250-102 ...............................269, 317 883700-902 ........................................273 922700-902 ...............................245, 262 959701-906 ........................................253
877250-105 ...............................269, 317 883700-905 ........................................268 922700-932 ...............................245, 262 959701-912 ........................................253
877250-106 ...............................269, 317 883700-906 ........................................268 922975-902 ......................243, 245, 262 959701-918 ...............................253, 255
877250-112 ...............................269, 317 883700-909 ........................................268 922975-906 ...............................245, 262 959731-902 ...............................243, 253
877250-114 ...............................269, 317 883700-912 ........................................268 922975-932 ...............................245, 262 959731-906 ...............................243, 253
877952-101 ...............................317, 330 883700-922 ........................................268 923700-902 ...............................245, 263 959731-912 ...............................243, 253
877952-102 ...............................283, 317 883725-901 ........................................281 923700-932 ...............................245, 263 959733-902 ........................................253
877952-105 ......................283, 317, 330 883750-902 ........................................372 923975-902 ...............................245, 262 959733-906 ........................................253
877952-106 ...............................283, 317 883750-905 ........................................372 923975-932 ...............................245, 262 959733-912 ........................................253
877952-108 ...............................317, 330 883750-906 ........................................372 924700-902 ...............................243, 261 959741-902 ...............................243, 253
877967-102 ...............................273, 318 883750-909 ........................................372 924700-906 ...............................243, 261 959741-906 ...............................243, 253
877974-901 ........................................433 883952-302 ........................................283 924975-302 ...............................243, 260 959741-912 ...............................243, 253
877974-910 ........................................433 883952-701 ........................................330 924975-306 ...............................243, 260 959741-918 ......................243, 253, 255
878150-101 ...............................282, 318 883952-702 ........................................283 924975-902 ...............................243, 260 959743-901 ........................................325
878250-101 ...............................282, 318 883952-703 ........................................334 924975-906 ...............................243, 260 959743-902 ........................................253
880668-301 ........................................281 883952-704 ........................................334 925700-902 ...............................245, 263 959743-906 ........................................253
880668-901 ........................................281 883952-705 ........................................330 925700-932 ...............................245, 263 959743-912 ........................................253
880952-201 ........................................330 883952-706 ........................................283 925975-902 ...............................245, 262 959746-902 ........................................253
880952-202 ........................................283 883952-708 ........................................330 925975-932 ...............................245, 262 959746-906 ........................................253
880952-203 ........................................334 883952-710 ........................................283 926700-902 ...............................243, 261 959757-301 ...............................238, 325
880952-204 ........................................334 883952-712 ........................................283 926700-906 ...............................243, 261 959757-302 ...............................238, 252
880952-205 ........................................330 883952-714 ........................................334 926975-302 ...............................243, 260 959757-306 ...............................238, 252
880952-206 ........................................283 883967-302 ........................................273 926975-306 ...............................243, 260 959757-312 ........................................238
880952-208 ........................................330 883967-901 ........................................273 926975-902 ...............................243, 260 959757-901 ...............................238, 325
880952-302 ........................................283 883967-902 ........................................273 926975-906 ...............................243, 260 959757-902 ......................210, 238, 253
880952-701 ........................................330 883975-202 ........................................267 927700-902 ...............................243, 261 959757-906 ...............................238, 253
880952-702 ........................................283 883975-302 ........................................267 927700-906 ...............................243, 261 959757-912 ........................................238
880952-703 ........................................334 883975-305 ........................................267 927975-302 ...............................243, 260 959758-301 ...............................238, 325
880952-704 ........................................334 883975-306 ........................................267 927975-306 ...............................243, 260 959758-302 ...............................238, 252
880952-705 ........................................330 883975-309 ........................................267 927975-902 ...............................243, 260 959758-306 ...............................238, 252
880952-706 ........................................283 883975-312 ........................................267 927975-906 ...............................243, 260 959758-312 ........................................238
880952-708 ........................................330 883975-314 ........................................267 928700-902 ...............................243, 261 959758-901 ...............................238, 325
880952-710 ........................................283 883975-901 ........................................329 928700-906 ...............................243, 261 959758-902 ...............................238, 253
880952-712 ........................................283 883975-902 ........................................267 928975-302 ...............................243, 260 959758-906 ...............................238, 253
880952-714 ........................................334 883975-905 ........................................267 928975-306 ........................................260 959758-912 ........................................238
880967-201 ...............................267, 273 883975-906 ........................................267 928975-902 ...............................243, 260 959759-302 ...............................238, 252
880967-202 ........................................273 883975-909 ........................................267 928975-906 ........................................260 959759-306 ...............................238, 252
880967-302 ........................................273 883975-912 ........................................267 9300-1747 ..........................................199 959759-901 ...............................238, 325
880967-901 ........................................273 883975-914 ........................................267 9300-1748 ..........................................199 959759-902 ...............................238, 253
880967-902 ........................................273 883995-902 ...............................210, 372 9301-0407.............................................99 959759-906 ...............................238, 253
880975-201 ........................................329 883995-905 ........................................372 9301-0656.............................................53 959759-912 ........................................238
880975-202 ........................................267 883995-906 ........................................372 9301-0722 ..........................................200 959763-902 ........................................253
880975-205 ........................................267 883995-909 ........................................372 9301-0895.............................................13 959763-906 ........................................253
880975-209 ........................................267 884950-507 ........................................283 9301-0978 ..........................................199 959763-912 ........................................253
880975-212 ........................................267 884950-526 ........................................283 9301-1291 ..........................................106 959764-902 ...............................243, 253
880975-302 ........................................267 884950-543 ........................................283 9301-1337.............................................58 959764-906 ...............................243, 253
880975-305 ........................................267 884950-567 ........................................267 9301-1420.............................................53 959764-912 ...............................243, 253
880975-306 ........................................267 884950-577 ........................................281 9301-1421.............................................53 959764-918 ......................243, 253, 255
880975-309 ........................................267 884973-701 ........................................433 9301-1446.............................................99 959790-918 ...............................253, 255
880975-312 ........................................267 884973-901 ........................................433 9301-1450.............................................53 959793-901 ........................................325
880975-314 ........................................267 884973-902 ........................................433 9301-6341.............................................53 959793-902 ........................................253
880975-901 ........................................329 884975-202 ........................................267 9301-6342.............................................53 959793-906 ........................................253
880975-902 ........................................267 895050-902 ......................317, 373, 466 930990-902 ........................................260 959793-912 ........................................253
880975-905 ........................................267 895050-906 ......................317, 373, 466 930990-906 ........................................260 959793-918 ...............................253, 255
880975-906 ........................................267 895050-909 ......................317, 373, 466 931975-902 ........................................262 959794-902 ........................................243
880975-909 ........................................267 895100-902 ......................317, 373, 466 931975-906 ........................................262 959931-902 ...............................243, 252
880975-912 ........................................267 895100-906 ......................317, 373, 466 931975-932 ........................................262 959931-906 ...............................243, 252
880975-914 ........................................267 895100-909 ......................317, 373, 466 931975-936 ........................................262 959931-912 ...............................243, 252
880995-202 ........................................372 895150-902 ......................317, 373, 466 932967-902 ........................................260 959931-918 ......................243, 252, 255
880995-205 ........................................372 895150-906 ......................317, 373, 466 932967-906 ........................................260 959933-902 ........................................252
652
PART NUMBER INDEX
WWW.AGILENT.COM/CHEM/LC 653
PART NUMBER INDEX
654
PART NUMBER INDEX
WWW.AGILENT.COM/CHEM/LC 655
PART NUMBER INDEX
656
PART NUMBER INDEX
WWW.AGILENT.COM/CHEM/LC 657
PART NUMBER INDEX
658
PART NUMBER INDEX
WWW.AGILENT.COM/CHEM/LC 659
APPLICATION TITLE INDEX
660
APPLICATION TITLE INDEX
Fast LC/MS/MS analysis of group 4 High sensitivity with capillary columns ..............453 O
pharmaceuticals from EPA 1694 ..........................583 Higher resolution of intact monoclonal antibody...368 Oligosaccharides.......................................................610
Fast method for ginseng analyses Higher resolution of oxidation study..........354, 368 Opiates (drugs of abuse) by LC/MS....................630
scaled from a traditional method.........................612 Hormones/steroids..................................................633 Optimize separations with
Fast separation of recombinant Human serum: Low abundance Eclipse XDB selectivity options.............................259
human erythropoietin..............................................553 protein isolation and identification Optimizing protein separations with
Fast separation of reduced from 1-D gel band by LC/MS .......................454, 566 Agilent weak cation-exchange columns............558
monoclonal antibody...............................................375 Hyaluronic acid..........................................................527 Organic acid analysis...............................................338
Fast vitamin E analysis Hydrophilic purine/pyrimidine separation..........579
on Rapid Resolution HT ..........................................608 Organic acids separated on ZORBAX SB-Aq.......581
Fast, high-resolution separation of Overlay of UV and Light Scattering 90° for a
peptides and proteins with
I Sample of y-globulins, Illustrating Monomer,
Poroshell 300SB-C18 ...............................................572 Ibuprofen: Optimizing selectivity Dimer, Trimer, and Aggregate Peaks....................430
with RRHT Columns.................................................618 Overlay of UV and light scattering 90° for a
Faster analysis of USP Method
for simvastatin tablet...............................................615 Improved peak shape of basic sample of γ-globulins, illustrating monomer,
compounds using Bonus-RP .................................279 dimer, and trimer peaks ..........................................430
Faster separation of sulfa drugs ...........................616
Faster separations using Agilent Improved reproducibility
weak cation-exchange columns...........................560 of monoclonal antibodies.......................................369 P
Fat-soluble vitamins on Improved resolution with smaller particle size pH gradient elution for improved separation
ZORBAX Eclipse XDB-C8........................................605 with Agilent weak cation-exchange columns.....559 of monoclonal antibody charged variants..........561
Five different bonded phases Increase peak capacity with RRHT columns.....240 PLgel LS column .......................................................503
provide selectivity options......................................266 Increased resolution for peptide mapping....357, 369 PLgel Olexis reveals true modalities
Flavoring agents........................................................602 Intact MAb monomer across the range of polyolefins.............................508
Food colors, FD&C....................................................602 and dimer separation.............................355, 419, 563 Parabens: High speed separation.........................604
Four different 300SB Peak shape and efficiency are better
bonded phases optimize separation L with ZORBAX Eclipse Plus.....................................249
of large polypeptides................................................371 LC/MS analysis of angiotensin Peptide RP-HPLC/ESI-MS using NH4OH
Fraction analysis – on Extend-C18 ...........................................................377 mobile phase yields both positive and
the concentration overload purification .............469 LC/MS performance test mix negative ion spectra................................................573
for Polaris C8-A .........................................................299 Peptides/proteins:
G Lamotrigine ................................................................642 Effect of elevated temperature.....................370, 571
Glycosylated proteins: Large Molecules Large fibrous proteins.....................................309, 392 Peptides/proteins:
on Poroshell 300SB-C18 and 300SB- ..................565 Liquid chromatography phase Equivalent gradient separations............................571
Goldenseal and related alkaloids on test mixture (LPTM) on Pursuit C8 ......................290 Peptides: Effect of TFA concentration........370, 569
Rapid Resolution Eclipse XDB-C18 ......................625 Local anesthetics......................................................619 Peptides: Separation of antiotensins
Good peak shape over a wide pH range Long life at high pH with 300Extend-C18...........378 I, II, III with TFA and NH4OH ................................570
with ZORBAX Eclipse XDB ....................................257
Long life at high pH with Extend-C18..................275 Peptides: Separation of antiotensins
Gradient optimizations for ultra-fast
analysis of reduced monoclonal antibody .........556 Long lifetime of RRHT columns I, II, III with TFA and NH4OH ................................632
at elevated temperatures........................................241 Phenols, substituted ................................................592
Guaifenesin: USP analysis of guaifenesin..........629
Phenoxyacid herbicides ..........................................591
H M Plant hormones: Rapid gradient
HPLC of 25 bp DNA ladder ..........................307, 388 Mechanical stability of Pursuit XRs.....................289 elution separation.....................................................593
HPLC separation of 12 phenols perfomed Metronidazole: Updating USP methods..............629 Plasticized PVC.........................................................501
in just 5 minutes – and under 400 bar – using Microbore HPLC for sensitive peptide analysis ...462 Polyamides .................................................................509
an Agilent Poroshell 120 EC-C18 column .............231 MicroBore Poroshell 300 columns Polycyclic aromatic hydrocarbons
HSA tryptic digest on provide maximum sensitivity for LC/MS............382 according to EPA Method 610...............................589
ZORBAX Rapid Resolution HT 1.8 µm.................566 Mixture of beta blockers ........................................613 Polyester .....................................................................519
Heparin........................................................................526 Monoclonal IgG1 chains: Polyesterimide...........................................................520
Herbicide/pesticide standards: Separation on Poroshell 300SB-C8 .............383, 567
Polyethylene Glycol/Oxide standards .................542
Effect of bonded phase ...........................................588 Morphine and metabolites:
Herbicides on different bonded phases ..............587 Polyethylene glycols .......................................307, 388
Extracted blood plasma sample separation.......630
Herbicides: Rapid separation .................................591 Polymethylmethacrylate in DMF...........................517
High Resolution of 24 Amino Acids N Polymethylmethacrylate standards......................540
Using ZORBAX Eclipse AAA Protocol.................396 Naproxen analysis ...................................................611 Polyol...........................................................................501
High purity and high recovery Natural products – capsaicin and Polyphenylene Sulfides...........................................500
with ZORBAX PrepHT columns ............................315 dihydrocapsaicin on Pursuit XRs C18 .................319 Polystyrene standards .............................................538
High resolution and fast analysis Neutraceuticals: Extract from green tea.............603 Polyurethanes............................................................520
on RRHT Eclipse PAH column...............................254 Neutraceuticals: Polyvinyl alcohol ..............................................526, 528
High resolution normal-phase separation Hypericin separation in St. John's Wort.............632 Pore size choice: Mouse IgG ................................421
of octylphenoxy ethanol surfactant
on ZORBAX CN.........................................................327 New levels of sensitivity and resolution.............235 Pore size choice: Proteins......................................421
High resolution separation of a Nucleosides, purines and pyrimidines ................564 Poroshell 120 EC-C18 for fast
Poly-T-Oligonucleotide size standard Nucleosides: Separation of deoxy UHPLC separations ..................................................232
spiked with 10-mer, 15-mer, 30-mer and ribonucleosides.................................................568 Poroshell 300 columns separate
and 50-mer (main peaks)........................................408 Nucleotides: Separation of mononucleotides ...568 proteins and peptides in seconds ........................381
WWW.AGILENT.COM/CHEM/LC 661
APPLICATION TITLE INDEX
662
COMPOUND INDEX
Compound Index
A Anthracene ...............................................189, 589-591 2-Butanone (MEK) – DNPH...................................584
a-1-Antichymotrypsin.....................................454, 566 Butylbenzene.............................................................299
Acebutolol..................................................................613
Antithrombin-III................................................454, 566 Butylparaben ...........................................189, 241, 604
Acenaphthene...................................................589-591
Apomyoglobin ...........................................................572 n-Butyraldehyde – DNPH.......................................584
Acenaphthylene................................................589-591
Aprotinin.....................................................................403
Acephate ....................................................................594
Arabinose ...................................................................341
Acetaldehyde – DNPH ............................................584
Arabitol........................................................................339 C
Acetamide ..................................................................615 Caffeine.........................232, 235, 250, 258, 276, 299,
2-Arachinoylglycerol ................................................381
2-Acetamidophenol.........................................235, 615 316, 334, 599, 608, 615
Arginine .............................................................396, 564
Acetaminophen.....................235, 250, 615, 618, 628 Calcium .......................................................................173
Arsenate .....................................................................175
Acetanilide ........................................................235, 618 Calmodulin .................................................................571
Arsenite ......................................................................175
Acetate................................................................174-175 Canadine.....................................................................625
Ascorbic acid.............................................................612
Acetic Acid.................................................................581 Carbamazepine.................................................618, 632
Asparagine........................................................396, 596
Acetone ......................................................................582 Aspartame.......................................232, 290, 299, 599 Carbaryl.......................................................................594
Acetone – DNPH......................................................584 Aspartic acid.....................................................396, 596 Carbendazim ............................................235, 580, 594
Acetophenone...........................................................599 Aspartic acid-phenylalanine dipeptide................599 Carbonate...................................................................175
6-Acetylmorphine .....................................................628 Atenolol ......................................................................613 Carbonic Anhydrase ......................370-371, 381-382,
Acetylsalicylic acid........................235, 250, 618, 628 Atrazine......................................................587-588, 591 408, 571-572
Acrolein – DNPH......................................................584 Azide..........................................................172, 175, 421 Carvone.......................................................................602
Adenine..............................................................564, 579 Catalase ......................................................................432
Adenosine .........................................................564, 568 Catechol...................................230-231, 584, 603, 625
Adonitol ......................................................................339 B Cefazolin .....................................................................620
Adrenaline..................................................................578 Barberine....................................................................625 Cefepime.....................................................................217
Alanine...............................................................396, 564 Barbital........................................................................258 Cefotaxime .................................................................620
Alanine-3-Glycine-4.........................................308, 390 Barbitone....................................................................643 Ceftazidime ................................................................620
Albuterol ............................................................325, 583 Beclomethasone.......................................................290 Celecoxib ....................................................................235
Alprenolol ...................................................................613 Bendroflumethiazide................................................189 Cephaclor ...................................................................280
2-Amino-5-azotoluene .............................................183 Bentazon ....................................................................587 Cephalexin..................................................................280
4-Aminobenzoic acid ......................................290, 621 Benzaldehyde – DNPH ...........................................584 Cephoxitin ..................................................................280
p-Aminobenzoic acid ...............................................609 Benz(e)pyrene ..........................................................591 Cephuroxime..............................................................280
3-Amino-benzonitrile ...............................................585 Benzidine..................................................183, 583, 598 Chlorate.......................................................................172
7-Aminoclonazepam ................................................289 1,2-Benzisothiazol-3(2H)-one ................................580 Chloride......................................................172, 174-175
2-Amino-4,6-dinitrotoluene ............................586-587 Benzisothiiazol-3(2H)-one ......................................235 Chloroaniline.....................................................583, 598
4-Amino-2,6-dinitrotoluene ....................................587 Benzo(a)anthracene .......................................589-591 m-Chloroaniline.........................................................585
4-Amino-4,6-dinitrotoluene ....................................586 Benzo(a)pyrene.................................................589-591 o-Chloroaniline..........................................................585
7-Aminoflunitrazepam .............................................289 Benzo(b)fluoranthene......................................589-591 p-Chloroaniline..........................................................585
2-Aminonaphthalene ...............................................183 Benzocaine ................................................................619 2-Chlorobenzoic ........................................................623
2-Amino-4-nitrotoluene...................................586-587 Benzo(g,h,i)perylene........................................589-591 Chlorocaine................................................................619
2-Amino-6-nitrotoluene...................................586-587 Benzoic acid....................................232, 290, 389, 580, 4-Chloro-3-methylphenol ........................................592
4-Amino-2-nitrotoluene...........................................586 602, 609, 621, 629 5-Chloro-2-methyl-4-isothiazolin-3-one...............235
Amitriptyline ....................................258, 289, 635-637 Benzo(k)fluoeanthene.....................................589-591 2-Chlorophenol..........................................................592
cis-10-OH -Amitriptyline..........................................637 Benzophenone ..........................................................618 o-Chlorophenoxyacetic acid..........................591, 593
trans-10-OH-Amitriptyline.......................................637 Benzoylecgonine ......................................................627 p-Chlorophenoxyacetic acid..........................591, 593
Ammonium ................................................................173 Benzthiazuron ...........................................................588 o-Chlorophenoxy proprionic acid..........................593
Amylbenzene.............................................................299 n-6-Benzyl adenine ..................................................593 Chlorothiazide............................................................189
Amylobarbitone.........................................................643 5-Benzyl-3,6-dioxo-2-piperazineacetic acid........599 Chlorpheniramine ..........................275, 279, 617, 628
Anadamine.................................................................236 Berberine...........................................................251, 617 Chlorthalidone...........................................................189
Androstadiene 3,17 dione ......................................613 Biosynthetic human insulin...................................384 Chrysene.............................................................589-591
Anethole .....................................................................602 Biotin (B7)..................................................................612 Chymotrypsinogen A ...............................................410
Angiotensin I .................308, 377, 389-390, 462, 570 Biphenyl......................................................................189 Cimetidine ................................................325, 583, 637
Angiotensin II ..........................194, 308, 370, 377, 381, Bovine carbonic anhydrase ..........................407, 576 d-Cinchonine.....................................................266, 619
389-390, 462, 570-572 Bromide ......................................................................172 Cinnamaldehyde .......................................................599
Angiotensin III........................308, 377, 389-390, 570 BSA...................................382, 425-426, 432, 576-577 Ciprofloxacin..............................................................620
Aniline .......................................................183, 583, 598 Bumetanide ...............................................................189 Citrate..........................................................................174
p-Cl-Aniline.................................................................183 Buspirone ...................................................................616 Citric Acid................................338, 396, 581, 609-610
Anisidine.....................................................................598 Butacaine ..........................................................266, 619 Clindamycin ...............................................................620
p-Anisidine .................................................................585 tert-butanol ................................................................582 Clomipramine ............................................................289
WWW.AGILENT.COM/CHEM/LC 663
COMPOUND INDEX
664
COMPOUND INDEX
WWW.AGILENT.COM/CHEM/LC 665
COMPOUND INDEX
Prednisolone.....................................................290, 632 Sorbic acid................................................290, 609, 621 o-Toluidine ................................................183, 583, 598
Prednisolone acetate...............................................290 Sorbitol.......................................................338-341, 604 Trehalulose.................................................................600
Procainamide....................................................616, 640 Stachyose..........................................................340, 604 Triamcinolone ...................................................290, 635
Procaine....................................................266, 619, 640 Succinate....................................................................174 Triamcinolone acetonide ........................................290
Progesterone ....................................................613, 638 Succinic Acid...........................................338, 581, 610 2,4,6-Trichlorophenol................................................592
Promethazine.............................................................632 Sucrose ....................................338, 340-341, 600, 604 2,4,5-Trichlorophenoxyacetic acid.........................591
Prometon....................................................................587 Sulfachloropyridazine ..............................................616 3,4,5-Trichlorophenoxyacetic acid.........................593
Prométryne........................................................587, 591 Sulfadiazine......................................249, 616, 640-641 2,4,5-Trichlorophenoxypropionic acid (Silvex)....591
Propanil..............................................................587, 591 Sulfadimethoxine.............................................616, 641 3,4,5-Trichlorophenoxyproprionic acid .................593
n-Propanol..................................................................582 Sulfamerazine..................................249, 616, 640-641 Triflupromazine..........................................................632
Propanolol ..................................................................636 Sulfamethazine ........................................616, 640-641 Trimipramine ...........................258, 289, 632, 635-636
Propazine...................................................587-588, 591 Sulfamethizole..................................................616, 641 1,3,5-Trinitrobenzene........................................586-587
Propionaldehyde – DNPH ......................................584 Sulfamethoxazole ..........................249, 258, 616, 632 2,4,6-Trinitrotoluene .........................................586-587
Propoxur .....................................................................594 Sulfamethoxypyridazine..........................................616 Tripelennamine..........................................................632
Propranolol......................................241, 613, 636, 640 Sulfanilamide............................................249, 640-641 Triphenylene...............................................................299
Propylparaben ..................................................189, 604 Sulfanilic acid ............................................................641 Triprolidine................................................275, 279, 617
Protriptyline..............................................396, 564, 632 Sulfapyridine..............................................................616 Tryptophan (TRP)....................................396, 459, 564
Pseudoephedrine....................................275, 617, 628 Sulfate........................................................172, 174-175 Tyrosine (TYR) .........................................396, 459, 564
Pymetrozine ...............................................................594 Sulfathiazole ............................................249, 616, 640 Tébuthiuron................................................................591
Pyrene .................................................................589-591 Sulfisoxazole..............................................................641
Pyridine ..............................................................249, 389 Sulfmethazine............................................................249
Pyridoxine...........................................................605-607 Sulfur ...........................................................................507 U
Pyridoxyl phosphate (B6) .......................................612 Sulindac .............................................................235, 615 Uracil...............240-241, 258, 299, 425-426, 564, 579
Pyrilamine...................................................................334 Uridine................................................................564, 568
Pyroglutamate ...........................................................174
Pyruvate......................................................................174 T
Talbarbitone ...............................................................643 V
Tartarate......................................................................175 Valeraldehyde – DNPH ...........................................584
Q Tartaric acid.......................................................338, 610 Valine..................................................................396, 564
Quercetin....................................................................266 Tebuthiuron ................................................................587 Valine3-Glyine4 (Na-acetylated) .................308, 390
Terbutylazine..............................................................588 Valine3-Valine4 (Na-acetylated)..................308, 390
Terphenyl-d14 ...........................................................591 Valine-tyrosine-valine ..............................................572
R o-Terphenyl.................................................................299 Vitamin A....................................................................605
Raffinose...................................................340, 600, 604 Testosterone .....................................................312, 613 Vitamin B12 ...............................................................421
Ranitidine...........................................................325, 583 Tetracaine..........................................................266, 619 Vitamin C...................................................605-606, 609
Reserpine...........................................................290, 299 2,3,4,6-Tetrachlorophenol........................................592 Vitamin D2..................................................................605
Resorcinol..................................................230-231, 584 Tetryl ....................................................................586-587 Vitamin D3..................................................................605
Retinol .........................................................................605 Theobromine............................................276, 316, 608 Vitamin E (a-VE)........................................................605
Retinol acetate..........................................................605 Theophylline ............................................276, 316, 334
Retinol palmitate ......................................................605 Thiabendazole ...........................................................594
Rhamnose ..................................................................600 Thiamine pyrophosphate (TPP) ............................594
W
Riboflavin (B2)..........................................605-606, 612 Thiamine (B1)...................................................607, 612 Warfarin .....................................................................640
Ribonuclease (RNase)...................371, 381, 571-572 Thiocyanate ...............................................................172
Ribonuclease A.......................370, 400, 403, 425-426, Thiosulfate .................................................................172
558-560, 571-572, 576 Thiourea.............................................................189, 590
X
Ribose..........................................................................600 Threonine (THR) ..............................................396, 564 Xanthosine-5’-monophosphate (XMP) ...............568
Ropivacaine................................................................619 Thymidine...................................................................564 Xylitol...........................................................................339
Thymine .............................................................564, 579 Xylose..........................................................................600
Thymol ........................................................................602
S Thyroglobulin...................................421, 425-426, 432
Saccharin....................................................................232 a-Tocopherol.....................................................605, 608
Saccharose ................................................................600 b-Tocopherol ..............................................................608
Salicylic acid ...................................235, 290, 618, 621 g-Tocopherol......................................................605, 608
Sarcosine...........................................................396, 564 Tocopherol acetate...................................................605
Scopolamine .....................................................275, 617 o-Tolidine.....................................................................598
Sebutylazine...............................................................588 Tolmetin ...........................................235, 615, 618, 622
Selenate......................................................................175 m-Tolualdehyde – DNPH.........................................584
Serine .................................................................396, 564 Toluene..............................................240, 299, 589-591
Simazine .............................................................587-588 m-Toluic.......................................................................623
Sodium ........................................................................173 m-Toluidine.................................................................585
666
ORDERING INFORMATION
Ordering Information
Easy Ordering Terms and Conditions
Discounts and Delivery
Agilent Technologies specializes in fast delivery. In the US, if you call before 2 PM EST, we will ship your
order that day. You may also request overnight express delivery before 6 PM EST and you will have your
order the next day. Volume discounts on a variety of individual products are offered when the entire quantity
is shipped to one address at one time.
A shipping and handling fee will be added to your order unless the purchase is over $2000 US for orders
place online or over $4000 for orders place via phone. Special shipping (i.e., overnight in the US) is
available in most regions at an additional cost.
Agilent is required to collect all state and local sales taxes unless the buyer's tax-exempt certificate is on file
with Agilent Technologies. Please be prepared to provide a copy if it is not on file, when placing your order.
Please check with your Agilent Customer Service Representative, local Authorized Distributor, or the Agilent
website for current prices, special offers, promotions and discounts when placing your order.
Satisfaction Guaranteed
If you are not satisfied with your Agilent product within the first 60 days, you may return your purchase in its
original condition for a full refund or credit. A return policy statement is included in every Agilent shipment
and posted under Product Information on the website. In the US and Canada, please call for a Return
Authorization form and return instructions at 1-800-227-9770. If your Agilent product was purchased from
a distributor, please contact the distributor.
Shipping Damages
If items are damages in transit, please follow the instructions below:
• If a shipment is visibly damaged upon arrival, do not accept it until the person making the delivery has
endorsed the bill of lading with statement for the extent of the damage.
• If any damage is found after unpacking, retain all cartons and inner packaging and immediately
request an inspection from the carrier.
• Notify the Agilent Customer Contact Center at 1-800-227-9770 about the damaged shipment so that
we can make the appropriate sales adjustment and/or provide you with return instructions (Sales order
number, product number and quantity damaged will be needed).
WWW.AGILENT.COM/CHEM/LC 667
ORDERING INFORMATION
Payment Options
• In the US, Visa, MasterCard, Discover and American Express are accepted with a minimum order of
$20 (not applicable in all countries).
• Email ePay@agilent.com to make an electronic payment using the ACH/EFT (Automated Clearing
House/Electronic Funds Transfer) method.
• Establish a charge account through your Agilent Customer Service Representative or Your Local Agilent
sales office. An account number will be assigned to you for charging your purchases. Payment terms
are net 30 days from the invoice date. All orders are subject to credit approval.
We will be happy to supply a price quote via, phone, email or fax if you need it in writing.
Warranties
All Agilent Technologies products in this catalog are designed and manufactured to stringent standards
under the Agilent quality system registered to ISO 9001. At Agilent, we back every product with a 90-day
warranty and a money-back guarantee. If Agilent receives notice of defects during the warranty period.
Agilent shall, at its option, either repair or replace products which prove to be defective. If Agilent is unable,
within a reasonable time, to repair or replace any product to a condition as warranted, the buyer shall be
entitled to a refund of the purchase price upon return of the product to Agilent. The warranty period for
each product begins on the day of shipment.
This warranty shall not apply to any defect, failure, or damage caused by improper use or improper or
inadequate maintenance or care. This warranty is exclusive and no other warranty, whether written or oral,
is expressed or implied. Agilent specifically disclaims the implied warranties of merchantability and fitness
for particular purposes. The remedies provided herein are the buyer's sole and exclusive remedies. In no
event shall Agilent be liable for direct, indirect, special, incidental, or consequential damages (including loss
of profits) whether based on contract, tort, or any other legal theory.
668
ORDERING INFORMATION
Tax:
Total:
For Assistance: Please call the Agilent Technologies Customer Contact Center at 1-800-227-9770 (U.S. and Canada)
Email Node: cag_sales-na@agilent.com
Fax Number: 302-633-8901 U.S. and Canada
Note: 1. All pricing, tax, discount, and availability information is subject to verification by Agilent Technologies.
2. Shipping and handling is free for orders over $2000 US.
WWW.AGILENT.COM/CHEM/LC 669
ORDERING INFORMATION
Tax:
Total:
For Assistance: Please call the Agilent Technologies Customer Contact Center at 1-800-227-9770 (U.S. and Canada)
Email Node: cag_sales-na@agilent.com
Fax Number: 302-633-8901 U.S. and Canada
Note: 1. All pricing, tax, discount, and availability information is subject to verification by Agilent Technologies.
2. Shipping and handling is free for orders over $2000 US.
670
ORDERING INFORMATION
Tax:
Total:
For Assistance: Please call the Agilent Technologies Customer Contact Center at 1-800-227-9770 (U.S. and Canada)
Email Node: cag_sales-na@agilent.com
Fax Number: 302-633-8901 U.S. and Canada
Note: 1. All pricing, tax, discount, and availability information is subject to verification by Agilent Technologies.
2. Shipping and handling is free for orders over $2000 US.
WWW.AGILENT.COM/CHEM/LC 671
NOTES
672
THE ESSENTIAL CHROMATOGRAPHY & SPECTROSCOPY CATALOG LC & LC/MS
For more information
Buy online:
www.agilent.com/chem/store
Contact us:
www.agilent.com/chem/contactus
LC AND LC/MS
5991-1059EN