Jfy Solar Pump User Manual
Jfy Solar Pump User Manual
Jfy Solar Pump User Manual
User Manual
I
Preface
Thank you very much for using the SPRING series of solar pumping inverter produced by
Shenzhen JFY Tech. Co., Ltd.
Please be sure to read this manual carefully before installation and use in order to give full play
to the performance of this product and ensure the safety of user and equipment.
Please preserve the manual in an orderly manner in order to subsequently facilitate the routine
inspection and maintenance of the inverter and find out the cause of abnormity and treatment
countermeasure.
If there are any puzzling questions or specific requirement during using, please contact the
distributors of our company or directly keep in touch with the technology service center of our
company.
The manual will be subject to change without any further notice.
II
Contents
Safety Instruction.............................................................................................................I
Packing List...................................................................................................................34
Warranty Agreement..................................................................................................... 35
III
JFY Technology Safety Instruction
Safety Instruction
The equipment is provided with several labels, some of them with a yellow
background, which are related to safety issues.
Make sure to read the labels and fully understand them before installing the
equipment.
The symbols are:
Equipment grounding conductor (Main
grounding protective earth, PE)
Alternate Current (AC) value
Phase
To avoid risk of electric shock from energy
stored in capacitor, please wait for at least 5
minutes to access the conductor part of input
5minutes
or output terminals of the inverter after it is
disconnected from the output of PV panel and
solar pump.
Caution: The temperature of metal enclosure
may be high during operation.
I
JFY Technology Safety Instruction
Purchase Inspection
Caution
1. Never install if you find inverter damage or lack of component, or else it
will cause occurrence of accident.
Installation
Caution
1. To ensure a good convective cooling effect, the inverter must be installed
vertically with at least 10 cm space left in the top and bottom.
2. It’s suitable for indoor and outdoor installations. Install it in the indoor
location which is possessed of ventilation opening or ventilating device. It
is forbidden to install where exposes directly to the sunlight.
3. Do not let the drilling remains fall into the inverter fin or fan during
installation in case that heat dissipation is effected.
4. No user serviceable parts inside.
5. It can apply with all types of PV panel; the systems can operate with or
without earthing.
Connection
Warning
1. Connection job must be performed by qualified electric professionals, or
else it will cause electrocution or fire.
2. Please confirm that input power has already been cut off before connection,
or else it will cause electrocution or fire.
3. Earth terminal must be reliably grounded, or else the inverter shell will have
a danger of being electrified.
4. The type selection of PV array, motor load and inverter must be reasonable,
or else the equipment will be damaged.
5. When the photovoltaic array is exposed to light, it supplies a D.C. voltage to
the PV inverter.
II
JFY Technology Safety Instruction
Caution
1. Please use the fasten terminal of the specified torque, or else it will cause
fire.
2. Do not connect the output terminal of the inverter to the capacitor and
phase-advanced LC/RC noise filter. It is recommended to use the output
reactor when the distance between the inverter and motor load exceeds
100m.
Running
Warning
1. Energize after confirming the correct connection or else it will damage the
inverter or cause fire.
2. Do not modify the connection during electrifying, or else it will cause
electrocution.
3. Don’t block any of the ventilation openings.
Caution
1. Adjust partial control parameters according to the steps indicated by the
manual before its first running. Do not change the control parameters of the
inverter randomly, or else it will cause damage to the equipment.
2. Because the heat sink's temperature is high during running, do not touch it
for a long time, or else it will cause burn.
3. In the condition of altitude over 1000m, the inverter should be derated for
use, that is, output current will be de-rated by 10% at every 1500 m
increment of height.
Others
Warning
1. Maintenance and inspection must be performed by the qualified electric
professionals.
2. Do not dismantle the inverter during electrifying. Conduct maintenance and
inspection at least 5 minutes after the power off.
III
JFY Technology Safety Instruction
3. It is absolutely forbidden to reconstruct the inverter by oneself, or else it
will cause personnel injury or equipment damage.
4. Treat the inverter as industrial waste when processing the abandoned
inverter. It is possible that the electrolytic capacitor will explode during
incineration and that part of components will produce toxic and harmful
gas.
5. Pollution degree classification: Pollution degree 3.
IV
JFY Technology Products Introduction
DSP TI America
Option of up and down water level detection and control circuit is available.
Protection level IP65 (machine type’s rated power less than 22 kW); ambient
temperature for using: -10 ~ +50˚C.
Protective class: Class I; Overvoltage category PV: OVC II.
www.jfy-tech.com 2
JFY Technology Products Introduction
Product label is stick to the right side of outer casing, which contains the
important information such as product series, voltage, power grade and SW and HW
version that’ll provide important basis for product application, maintenance and after
service.
www.jfy-tech.com 3
JFY Technology Products Introduction
SPRING 2200 L
www.jfy-tech.com 4
JFY Technology Products Introduction
SPRING 3PH
900 680-850 500-680 200 7500 18 0-50
7500 380V
SPRING 3PH
900 680-850 500-680 200 9200 21 0-50
9200 380V
SPRING 3PH
900 680-850 500-680 200 11000 24 0-50
11K 380V
SPRING 3PH
900 680-850 500-680 200 13000 28 0-50
13K 380V
SPRING 3PH
900 680-850 500-680 200 15000 30 0-50
15K 380V
SPRING 3PH
900 680-850 500-680 200 18500 39 0-50
18K5 380V
SPRING 3PH
900 680-850 500-680 200 22000 45 0-50
22K 380V
SPRING 3PH
900 680-850 500-680 200 26000 54 0-50
26K 380V
SPRING 3PH
900 680-850 500-680 200 30000 60 0-50
30K 380V
SPRING 3PH
900 680-850 500-680 200 37000 75 0-50
37K 380V
SPRING 3PH
900 680-850 500-680 200 45000 91 0-50
45K 380V
SPRING 3PH
900 680-850 500-680 200 55000 112 0-50
55K 380V
Caution: Please be sure to select the appropriate model according to the PV
structure.
The input power in the above table indicates total multi-channel input power;
www.jfy-tech.com 5
JFY Technology Installation and Wiring
Damage or exfoliation
Inspect whole appearance
phenomenon
www.jfy-tech.com 6
JFY Technology Installation and Wiring
www.jfy-tech.com 7
JFY Technology Installation and Wiring
ensure that the mounting backplane can support the weight of the inverter.
www.jfy-tech.com 8
JFY Technology Installation and Wiring
Caution: Please identify with the plug to ensure the exact locations of the DC
Caution: Please ensure the AC output wiring based on the marks of the
sockets.
www.jfy-tech.com 9
JFY Technology Installation and Wiring
Wiring Diagram
www.jfy-tech.com 10
JFY Technology Installation and Wiring
www.jfy-tech.com 12
JFY Technology Installation and Wiring
Units: mm2
is ≤50°C.
www.jfy-tech.com 13
JFY Technology Installation and Wiring
input. Wire size of DC of each channel is selected and used as per the
Description
Caution: When use the water level sensors, Please connect high level signal
wire to A/O terminals S2 and COM; connect low level signal wire to A/O terminals
www.jfy-tech.com 14
JFY Technology Operation Control
Running
POWER Green Bright: Inverter is running
indicator light
Alarm indicator
ALARM Yellow Bright: Inverter is alarm
light
Fault indicator
FAULT Red Bright: System fault
light
www.jfy-tech.com 15
JFY Technology Operation Control
Run /Stop key 2. Stop control for the inverter for long
press 2s.
edited;
parameter is displayed;
parameter is displayed;
data editing.
Shift key
2. Viewing the running data when the
www.jfy-tech.com 16
JFY Technology Operation Control
Step 1: Ensure that the DC cable is connected correctly; unused DC plugs and
AC terminal cover is sealed.
Step 2: Connect the solar pump to the AC output terminals (see Fig.2-2). If
there have a AC switch between the pump and inverter (not suggest), Ensure the AC
switch is ON.
Step 3: Connect the PV array to the PV input terminals before ensure the DC
switch is OFF (see Fig.2-2).
Warning: It`s absolutely forbidden to turn on the AC switch when the inverter
is working, or may broken the inverter. The smart mind is turn off the DC switch first,
wait 5 minutes at least to avoid risk of electric shock from energy stored in capacitor,
full-automatic operation:
S00.10, and then modifies the output frequency by pressing Increment key or
Decrement key. In this mode: it`s need to press key to operate and long press
2s to stop.
strong enough, the output frequency will track automatically according to the sunlight.
The control cell array will export maximum power; in this mode, it isn`t need to
www.jfy-tech.com 17
JFY Technology Operation Control
control the inverter, it will start automatically if the sunlight is strong enough and
stop when the sunlight is weak. It could only view running data and parameter, and
inverter; if the rated power of the pump match the inverter, it isn`t need to edit the
parameter; if the rated power of the pump not exceed the inverter, it is need to edit the
www.jfy-tech.com 18
JFY Technology Operation Control
www.jfy-tech.com 19
JFY Technology Operation Control
Press UP or DOWN
or
key to view the S00.01
Represent:S00.01
↓
www.jfy-tech.com 20
JFY Technology Operation Control
Prompt: It can only view the control parameter during inverter operation. The
There are 3 kinds of status for operating panel display: running data display,
control parameter display, historical data display. The default status is the status of
running data display.
Press the can control inverter run/ stop, Press the and
www.jfy-tech.com 21
JFY Technology Operation Control
Set frequency of
↓
the inverter
Represent:50.00Hz
↓
Input voltage of the
inverter
Represent:542.3V
↓
Output voltage of
the inverter
Represent:379V
↓
Output current of
the inverter
↓
Represent:11.1A
Output frequency
of the inverter
Represent:50.00Hz
www.jfy-tech.com 22
JFY Technology Operation Control
or
Select the parameter to
↓
be viewed and edited
Represent:S00.10
↓
Edited the parameter
Represent:40.00Hz
Confirm the editing
↓ and save the parameter
value
Display the next code
Represent:S00.11
number
↓
Quit to the main
parameter
modification interface
for long press 2s Represent:S00 parameter group
www.jfy-tech.com 23
JFY Technology Operation Control
Prompt: It can only view the control parameter during inverter operation. The
Factory
value
off).
LED light).
Maximum
10Hz ~
S00.03 output S00.04 ~ 600Hz 50.00Hz
600Hz
frequency
Maximum
S00.06 ~
S00.04 running S00.05 ~ S00.03 50.00Hz
S00.03
frequency
www.jfy-tech.com 24
JFY Technology Operation Control
Factory
value
Minimum
0.00 ~
S00.05 running 0.00 Hz~ S00.04 0.00Hz
S00.04
frequency
0. Set by keyboard
1. Set by AI1
S00.06 Frequency set 0 ~ 11 0
2. Set by AI2
3. Set by AI3
Running 0.00 ~
S00.10 Only set in manual control model 50.00Hz
frequency set S00.04
Acceleration 0.0 ~
S00.11 0.0 ~ 3600.0s 22s
time 3600.0
Deceleration 0.0 ~
S00.12 0.0 ~ 3600.0s 10s
time 3600.0
Rated
0.01 ~
S02.02 frequency of 0.01 ~ S00.03 50.00Hz
S00.03
the motor
www.jfy-tech.com 25
JFY Technology Operation Control
Factory
value
S1 terminal
S05.01 0. null
function
1. Running in forward model
S2 terminal
S05.02 2. Running in reverse model
function
0 ~ 63 7. Fault reset 0
S3 terminal
S05.03 8. Run and stop
function
42. PV inverter forbidden
S4 terminal
S05.04 43. Water full
function
Temperature
0~
S07.11 of the rectifier
100.0℃
module
www.jfy-tech.com 26
JFY Technology Operation Control
Factory
value
Temperature
0~
S07.12 of the inverter
100.0℃
module
0. null
Current fault
S07.27 1. IGBT Shortcut 0
type
2. Inc over Current/Dec over
over Volt
4. Vbus low
S07.29
Fault type 5. Overload Tel
9. Shortcut GND 1
www.jfy-tech.com 27
JFY Technology Operation Control
Factory
value
12. No Water
Modify the control Modify the S00.01 value as 0. (in this mode, the
1
mode inverter controlled by keyboard)
Modify the rated Modify the S02.01 value follow the motor (Rated
2
power of the motor power).
Modify the rated Modify the S02.04 value follow the motor (Rated
4
voltage of the motor voltage).
www.jfy-tech.com 28
JFY Technology Operation Control
Modify the rated Modify the S02.05 value follow the motor (Rated
5
current of the motor current).
shining day)
frequency.
www.jfy-tech.com 29
JFY Technology Operation Control
operating frequency f.
(shutdown frequency).
Modify the control Modify the S00.01 value as 1. (in this mode, the
9
mode inverter controlled by terminals)
Caution: Please do not modify the control parameters of the inverter randomly,
www.jfy-tech.com 30
JFY Technology Fault Diagnosis
Code
Code Possible reason Countermeasures
description
PV array
voltage is lower
sunlight
intensity
www.jfy-tech.com 31
JFY Technology Fault Diagnosis
Inc over
Volt
Dec over Too high input
Volt Over-voltage Inspect PV array voltage
voltage
Con over
Volt
voltage
Vbus low Under-voltage Inspect PV array voltage.
Too weak sunlight
intensity
Current wiring
www.jfy-tech.com 32
JFY Technology Fault Diagnosis
Pumping empty,
To check with water level,
pump wire are all
pump running pump wire connection, pump
Lack load broken, pump is
empty rate is match with inverter
not match with
capacity or not.
inverter.
Pumping empty
Too low of the To check with water level
No Water A/O terminals
water level A/O terminals connection
connection error
www.jfy-tech.com 33
JFY Technology Fault Diagnosis
Cistern full
Too high of the To check with water level
Water Full A/O terminals
water level A/O terminals connection
connection error
Restart
Communication Device or circuit
Com Fault Turn to manufacturer for
fault damaged
service
If it cannot be reset or goes wrong after reset, check up on the cause, because
www.jfy-tech.com 34
JFY Technology Service and Maintenance
frequency Inspection
Inspection content Judgment standard
Routi Regul item
ne ar
www.jfy-tech.com 35
JFY Technology Service and Maintenance
Inspect
frequency Inspection
Inspection content Judgment standard
Routi Regul item
ne ar
No peculiar smell,
flammable,
explosive gas.
1. Excellent ventilation
1. Installation in installation
Cooling
√ environment environment.
system
2. Radiator 2. Radiator air duct not
blocked.
1. Stable vibration,
loosen.
www.jfy-tech.com 36
JFY Technology Service and Maintenance
Inspect
frequency Inspection
Inspection content Judgment standard
Routi Regul item
ne ar
uneven noise.
Filter Capacitor
Pulsating current of the main circuit will influence the performance of the
aluminum electrolytic filter capacitor, of which the degree will depend on the ambient
temperature and application condition. The inverter used under normal condition
should replace its electrolytic capacitor every 10 years. When the filter capacitor’s
electrolyte is leaking, safety valve bursting out or the capacitor main body expanding,
replace it immediately.
Cooling Fan
Of SPRING series of pumping inverter, all the inverters above SPRING 22kW
have cooling fans inside. Cooling fan’s service life is about 1, 5000 hours. If the fan
appears abnormal noise or produces vibration, replace it immediately.
www.jfy-tech.com 37
JFY Technology Service and Maintenance
Storage
If the storage is not used temporarily or stored for long time after purchasing, the
following notice should be paid attention to.
Avoid placing the inverter in high temperature or humid place or where there is
vibration and metal dust, and excellent ventilation should be ensured.
Inside filter capacitor performance of the inverter will decline for long–time
disuse. It is necessary to energize one time every 2 years to restore the performance
of the filter capacitor and inspect the inverter function at the same time. It is
necessary to increase the voltage through a DC power supply during energizing with
power-on time not less than 5 hours.
Warranty
The warranty of this inverter is 2 years. When any fault or damage occurs on the
product, within the warranty period, our company will provide free maintenance.
After the warranty time, we can provide lifetime paid warranty service.
Certain maintenance charge should be considered during warranty period if the
fault is caused by the following reason:
1. Fault caused by operating against the manual or surpass the standard
specification
2. Fault caused by self fix and modification without permission.
3. Fault caused by poor preservation
4. Fault by using the inverter in abnormal function
5. Machine damage caused by fire, salt corrosion, gas corrosion, earthquake,
storm, flood, lightning, abnormal voltage or other force majeure.
Prompt: Warranty only covers the body of the inverter.
www.jfy-tech.com 38
Warranty Card
Warranty length
factory day.)
Distributor (Seal)
Packing List
1. Main machine, 1
2. Operation manual( including warranty card), 1
3. Plug of the positive electrode of the PV array, 1
4. Plug of the negative electrode of the PV array, 1
5. Water level sensor plug, 1 (matching)
39
JFY-tech WARRANTY
Warranty Policy:
Warranty Period: The JFY-TECH SPRING Series Solar pumping inverters
provided by Shenzhen JFY Tech. Co., LTD. (abbr. JFY-tech) have 24-month
warranty period. The system accessories provided by JFY-tech have 12-month
warranty period.
Warranty Time Start: From the date that you get goods from our
distributors.
Warranty Evidence: The Purchasing Invoice from the distributors &
Product Series No.
Note: JFY-tech will count from 2 months later according to ex-factory date
as the warranty start time if client fails to provide the purchasing invoice and
other documents.
Scope: Any damages that occur during the WARRANTY PERIOD will be
evaluated by Distributor and JFY-tech to define its scope and responsibility.
Warranty Principles:
To provide better service to JFY-tech’s end users, all JFY-tech’s authorized
distributors are requested to respond to end users’ warranty claim, and the
authorized distributors will replace any products or parts of the product during
the warranty period proved to be defective in design or manufacture. The
following cases will be excluded from the warranty (the Distributors are liable
for investigation of the following):
40
6) The Product has been improperly stored and damaged while being stored
by the end user.
7) Transport damage, Painting scratch caused by shipping pumping. It
should declare to insurance company as soon as containers unload with
enough evidence.
8) Failure to observe the user manual, the installation guide, and the
maintenance regulations
9) Incorrect use or inappropriate operation
10) Insufficient ventilation of the device
11) The maintenance procedures relating to such product have not been
observed or performed to an acceptable standard.
12) Force majeure (e.g., lightning, overvoltage, storm, fire)
Claims that go beyond the rights cited in the warranty principles, in
particular claims for compensation for direct or indirect damages arising
from the defective device, for compensation for costs arising from
disassembly and installation, or loss of profits are not covered by JFY-tech’s
warranty, insofar JFY-tech is not subject to statutory liability.
41
Contact JFY
Shenzhen JFY Tech. Co., LTD
ADD: 5th Floor, 12th Block, Nangang Second Industrial Park, Nanshan
District, Shenzhen, P.R.China
Tel: +86-755-26632536
Fax: +86-755-26505986
Email: support@jfy-tech.com
42