Temperature Controller E5C2
Temperature Controller E5C2
Temperature Controller E5C2
E5C2
DIN-sized (48 x 48 mm) Temperature
Controller with Analog Setting
• Compact, low-cost Temperature Controller.
• Incorporates proportional control and reset adjustment function.
• Consecutive mounting possible using mounting adapter.
• Incorporates a plug-in socket, thus allows to DIN-track and flush
mounting.
Temperature
Ordering Information
Controller
■ Temperature Controllers
Setting Indication Control mode Output Model
method method
Thermocouple Platinum resistance Thermistor
thermometer THE
K (CA) L (IC) Pt100
Chromel vs. Iron vs.
alumel constantan
Analog setting No indication ON/OFF Relay E5C2-R20K E5C2-R20L-D E5C2-R20P-D E5C2-R20G
P Relay E5C2-R40K E5C2-R40L-D E5C2-R40P-D ---
Note: When placing an order, specify the standard temperature range and supply voltage in addition to the model number.
(e.g., E5C2-R20K 0°C to 200°C 100/110 VAC)
■ Input Ranges
Input Thermocouple Platinum resistance Thermistor (see note 2)
thermometer
K (CA) L (IC) Pt100 THE
Chromel vs. alumel Iron vs. constantan
Range °C 0 to 200 (5), 0 to 200 (5), –50 to 50 (2), –50 to 50 (2) (6 kΩ at 0°C),
0 to 300 (10), 0 to 300 (10), –20 to 80 (2), 0 to 100 (2) (6 kΩ at 0°C),
0 to 400 (10), 0 to 400 (10) 0 to 50 (1), 50 to 150 (2) (30 kΩ at 0°C)
0 to 600 (20), 0 to 100 (2),
0 to 800 (20), 0 to 200 (5),
0 to 1,000 (25), 0 to 300 (10),
0 to 1,200 (25) 0 to 400 (10)
°F 32 to 392 (10), 32 to 392 (10), 32 to 212 (5), ---
32 to 572 (20), 32 to 572 (20), 32 to 392 (10)
32 to 752 (20), 32 to 752 (20)
32 to 1,112 (40),
32 to 1,472 (50),
32 to 1,832 (50),
32 to 2,192 (50)
■ Characteristics
Setting accuracy ±2% FS max.
Hysteresis Approx. 0.5% FS (fixed)
Proportional band 3% FS (fixed)
Control period Approx. 20 s
Reset range (see note 1) 5 ±1% FS min.
Insulation resistance 20 MΩ min. (at 500 VDC)
Dielectric strength 2,000 VAC, 50/60 Hz for 1 min between charged terminals and uncharged metallic parts
Vibration resistance Malfunction: 10 to 55 Hz, 0.15-mm single amplitude for 10 min each in X, Y, and Z directions
Destruction: 16.7 Hz, 2-mm double amplitude for 2 hrs each in X, Y, and Z directions
Shock resistance Malfunction: 147 m/s2, 3 times each in 6 directions
Destruction: 294 m/s2, 3 times each in 6 directions
Life expectancy Electrical: 100,000 operations min. (3 A at 110 VAC, resistive load)
Ambient temperature Operating: –10°C to 55°C (with no icing or condensation)
Ambient humidity Operating: 45% to 85%
Degree of protection Front panel: IEC standard IP40 (see note 2)
Terminals: IEC standard IP00
Weight Approx. 200 g (with flush-mounting adapter)
Note: 1. No reset function is incorporated by any E5C2 model with ON/OFF control.
2. The model number of the special watertight cover conforming to IP66, NEMA4 is Y92A-48B.
Operation indicator
Operation Indicator
Indicator Output
Red Lit ON
Not lit OFF
Dimensions
Note: All units are in millimeters unless otherwise indicated.
Terminal Arrangement
48 x 48 (Bottom View)
44.8 x 44.8
Temperature
and Back Connecting Socket (Sold Separately)
Controller
Flush-mounting Panel
Y92F-30 Flush-mounting adapter
adapter
P3G-08 Back con-
necting socket
Tightening screw
(96) (see note)
N 2 3 4 5 6
L 93+1
0 141+1
0 189+1
0 237+1
0 285+1
0
60 min.
70 max.
Two,
4.5-dia. Note: Can also be
holes mounted to a
DIN track.
50 max.
20 max.
Model Y92A-48B
Installation
■ Connections
Input Output
Connect a thermocouple, the E52-THE@ Thermistor or platinum If the load circuit is a heating control system, be sure to connect the
resistance thermometer to the E5C2 as shown in the following illus- load to terminals 4 and 5. If the load circuit is a cooling control sys-
tration. tem, be sure to connect the load to terminals 4 and 6. If the heating
control system is connected to terminals 4 and 6 or the cooling con-
trol system is connected to terminals 4 and 5, the temperature of the
heating control system or cooling control system will be abnormal
Platinum resistance Relay output and a serious accident may result.
thermometer input
If the E5C2 is in frequent operation, such as proportional operation,
add an appropriate external relay to the E5C2 by considering the
Thermocouple input
capacity of the load and the life of the relay.
Power Supply
Power supply
100/110, 200/220, If a single power supply is used for the E5C2 and the load, the supply
Thermistor input 110/120, 220/240 VAC voltage of the power supply may vary greatly when the load is open
50/60 Hz or closed if the capacity of the power supply is not large enough.
Make sure that the capacity of the power supply is large enough so
that the supply voltage range will be always from 90% to 110% of the
rated supply voltage.
The E5C2 operates at either 50 or 60 Hz.
Hook
Duct
P2CF-08
20
Panel
Flush Mounting
Insert E5C2 into the square hole of the panel and insert an adapter
from the back so that there will be no space between E5C2 and the
panel. Then, secure the E5C2 with a screw.
Tightening screw
The P3G-08 can be wired in the same way as the P2CF-08.
Temperature
Controller
Dismounting
If flush mounted, loosen the screw of the adapter and disengage the
hooks for dismounting.
Temperature Setting
Do not turn the temperature setting knob of the E5C2 with excessive
force, otherwise the stopper of the knob may break.
Others
Do not remove the housing of the E5C2, otherwise the housing may
break.
To clean the surface of the E5C2, use a soft cloth wet with neutral
detergent or alcohol. Do not use any organic solvent, such as paint
thinner or benzine, strong acid or strong alkali to clean the surface of
the E5C2, otherwise the surface of the E5C2 will become damaged.