PR 6130 Cable Junction Boxes

PR 6135, PR 6136 Installation Cables


Cable Junction Boxes
Installation Cables
– Reliable connection between load cells
and the controller
– Cable junction boxes:
– Robust casing made of plastic,
aluminum, or stainless steel
– Protection class IP65 – IP68 | IP69K
– Large service temperature range
– Pressure equalizing membrane
– For four and six-conductor technology
– Installation cables:
– Safe connection over large distances
– Good chemical resistance
– Resistant to interference thanks to
double shielding
– High strength armored version available

Cable boxes PR 6130/04 and PR 6130/08 are The PR 6130/64Sa, PR 6130/65S, and The installation cables of the PR 6135 and
designed as a simple connection solution for PR 6130/68S cable junction boxes are the PR 6136 ranges were specifically developed
installation and load cell cables. Emphasis optimal connection solutions for installation for the special requirements placed on weig­
has been placed on important factors such as and load cell cables. They cover the whole hing technology in industrial environments.
high insulation resistance, prevention of the range of applications: use in potentially They bridge the gap between the junction
undesired effects of leakage current on the explosive atmospheres, and weighing systems boxes and weighing electronics.
measurement signal, etc. for use in legal metrology as well as those
not for such use. The casings are made of The very high transmission reliability of the
The PR 6130/08 plastic cable junction box stainless steel, making them equally well cable is thanks to its double shielding: For
connects up to eight load cell cables to one suited for use both in highly corrosive one, each testing wire is individually shiel­
installation cable. It meets the requirements environments as well as in the extremely ded. For two, the cable itself is additionally
for protection class IP65. The two quadruple hygienic production areas of the pharma­ protected by an overall shield. This ensures
cable glands are fitted for the load cell ceutical industry. Up to four load cells can that nothing can influence the measurement
cables and an M20 cable gland is fitted for be connected to the PR 6130/64Sa and signal during transfer. The blue PR 6136 is
the installation cable. PR 6130/65S cable junction boxes. The used in potentially explosive environments,
PR 6130/65S is especially space-saving due while the gray PR 6135 is designed for all
The PR 6130/04 cable junction box has an to its compact design. other applications. The cable is silicon-free,
aluminum casing, meeting the criteria for flame-resistant and highly resistant to
protection class IP67. It is suited for the Up to eight load cells can be connected to external influences.
connection of up to four load cells and one the PR 6130/68S cable junction boxes.
installation cable. Both cables are also available in an armored
All stainless steel boxes fulfill the require­ design for especially harsh environments.
In either box the cable wires are each laid ments of protection classes IP68 and IP69K, This design incorporates an additional stain­
separately (all lines with supply voltage + guaranteeing reliable measurements for less steel mesh and an extra thick casing
connected to one block). The shields them­ many years. for increased protection against cutting or
selves are similarly combined together. rodents.
PR 6130/08

120
75
60

200

PR 6130/04N
175

d4.2
57
42

52

80
PR 6130/64SA
189
169

d7
20
140
160
58.3

114

All dimensions in mm
PR 6130/65S 104

119
172
160
55.3

d
7
80
94

PR 6130/68S 240
225

68

115.4
140.4

166
d
8

206

All dimensions in mm

Technical Specifications
PR 6130/08 PR 6130/04N PR 6130/64Sa PR 6130/65S PR 6130/68S
Number of load cells 1 – 8 1 – 4 1 – 4 1 – 4 1 – 8
Material Polycarbonate Aluminum, painted 1.4301, AISI 304 1.4301, AISI 304 1.4404, AISI 316L
Protection class IP65 IP67 IP68 | IP69K IP68 | IP69K IP68 | IP69K
ATEX approval No No Yes Yes Yes
Service temperature range -30 °C to +70 °C -30 °C to +70 °C -30 °C to +80 °C -30 °C to +80 °C -30 °C to +80 °C
Transportation and storage -40 °C to +80 °C -30 °C to +80 °C -30 °C to +70 °C -30 °C to +70 °C -40 °C to +70 °C
Corner correction possible No Yes Yes Yes Yes
Insulation resistances
Wire – wire > 1000 MO > 5000 MO > 5000 MO > 5000 MO > 5000 MO
Wire – shield > 1000 MO > 5000 MO > 5000 MO > 5000 MO > 5000 MO
Wire – casing > 1000 MO > 5000 MO > 5000 MO > 5000 MO > 5000 MO
EMC in accordance with 10 V/m 10 V/m 10 V/m 10 V/m
DIN EN 61000-4-3
Overload test 500 VAC 500 VAC 500 VAC 500 VAC
Vibration resistance IEC68-2-6Fc, 5 g IEC68-2-6Fc, 5 g IEC68-2-6Fc, 5 g IEC68-2-6Fc, 30 g

The technical data given here serve only as a product description and must
not be interpreted as guaranteed characteristics in the legal sense.

Ordering Information
Model Description Packaging Weight (net | gross) Order number
PR 6130/08 Cable junction box 250 × 180 × 90 mm 0.5 kg | 0.87 kg 9405 361 30081
PR 6130/04N Cable junction box 250 × 170 × 70 mm 0.66 kg | 0.73 kg 9405 361 30041
PR 6130/64Sa Stainless steel cable box 260 × 180 × 70 mm 1.6 kg | 1.7 kg 9405 361 30642
PR 6130/65S Stainless steel cable box 260 × 180 × 70 mm 0.64 kg | 0.70 kg 9405 361 30652
PR 6130/68S Stainless steel cable box 260 × 180 × 70 mm 1.6 kg | 1.7 kg 9405 361 30682
Installation Cables
Wire Cross-section Function
Outer sheath red 0.75 mm2 + voltage
Shielding Shielding blue 0.75 mm2 - voltage
white 0.75 mm2 + sense

Sheath Armoring black 0.75 mm2 - sense


Sheath
green 0.56 mm2 + meas/LC out
gray 0.56 mm2 - meas/LC out

Cable Diameter Cable Inductivity Test Voltage


PR 6135: 9 mm 6135 0.80 µH/m 500 V (50 Hz, 1 min)
PR 6136: 11 mm 6136 0.80 µH/m VDE 0472 Part 508 Test B
PR 6135(A), PR 6136(A): 13 mm 6135A 0.80 µH/m
6136A 0.80 µH/m Resistance against Oil
Bending Radii EN 60811-2-1
PR 613x PR 613xA Conductor Resistance at 20 °C
rigid 55 mm 130 mm Supply and sense lines Flame Resistance
flexible 165 mm 260 mm 0.75 mm2 ≤ 26 O/km, EN 50265-2-1, IEC 60332-1
Measurement lines 0.56 mm2 ≤ 35 O/km
Cable Capacity
6135 250 pF/m Temperature range
6136 250 pF/m Operation and storage
6135A 250 pF/m flexible -40 °C to +90 °C
6136A 250 pF/m rigid -60 °C to +90 °C
for a short time up to +125 °C

The technical data given here serve only as a product description and must
not be interpreted as guaranteed characteristics in the legal sense.

Ordering Information
Model Description Packaging Gross weight Order number
PR 6135/01 Installation cable, gray 1 m (minimum length 51 m) Ring 9405 361 35012
PR 6135/11 Installation cable, gray 10 m Ring 1.8 kg 9405 361 35112
PR 6135/21 Installation cable, gray 20 m Ring 3.8 kg 9405 361 35212
PR 6135/31 Installation cable, gray 30 m Ring 5.2 kg 9405 361 35312
PR 6135/51 Installation cable, gray 50 m Ring 8.2 kg 9405 361 35512
PR 6135/12 Installation cable, gray 100 m Ring 13 kg 9405 361 35122
PR 6135/32 Installation cable, gray 300 m Ring 42 kg 9405 361 35322
PR 6135/01A Installation cable, gray 1 m (minimum length 10 m) Ring 9405 361 35019
PR 6135/22A Installation cable, gray 200 m Ring 43 kg 9405 361 35229
PR 6136/01 Installation cable, blue 1 m (minimum length 10 m) Ring 9405 361 36011
PR 6136/51 Installation cable, blue 50 m Ring 8.6 kg 9405 361 36511
PR 6136/12 Installation cable, blue 100 m Ring 18 kg 9405 361 36121
PR 6136/32 Installation cable, blue 300 m Ring 55 kg 9405 361 36321
PR 6136/01A Installation cable, blue 1 m (minimum length 10 m) Ring 9405 361 36019
PR 6136/22A Installation cable, blue 200 m Ring 43 kg 9405 361 36229

Sartorius Mechatronics T & H GmbH


Meiendorfer Strasse 205
22145 Hamburg, Germany
Specifications subject to change
without notice. Phone +49.40.67960.303
Printed in Germany. W Fax +49.40.67960.383
Publication No.: HPR2039-e13102
Order No.: 9498 761 30081
Version 10.2013
info.mechatronics@sartorius.com
www.sartorius.com

You might also like