Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Brosura ESM 2 - 5

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

ESM 2 – 5 Series

Screw Compressors

Maximum Flexibility User friendly Control System

Installation of the ESM 2–5 range is quick and easy due to the The Start/Stop operation ensures no idling time and no idling
flexible and compact design. Based on the individual customer energy costs. The ESM 2–5 as standard are equipped with
requirements, the compressors can be combined with different Start/Stop control and direct online starting. Hour meter and
options to provide everything from a stand alone compressor pressure gage are also included.
to the complete compressor station. Options include:
• Compressor base mounted The ESM 4–5 compressors as a premium option are equipped
• Compressor mounted on a tank with Star/Delta starting and the electronic Air Basic controller,
which provides the user with data on total hours of operation,
• Complete compressor station includes compressor
operating temperature and additional information such as:
and refrigerant dryer, both mounted on a tank
• Air filter replacement
• Oil filter replacement
• Separator filter replacement
Easy To Use
• Oil change
Thanks to user-friendly design of the ESM 2–5 range, the • Regular maintenance advice
compressors are ready for plug & play operation. Maintenance
is made easy by the removable side doors providing you with
With star delta the compressors can be set to unloaded
quick and easy access to all service points. The simple design
running with timed stop adjustable between 0 and 3 minutes.
minimizes the number of moving parts and as a result reliabili-
ty is increased and maintenance costs reduced.
The compressors are belt driven, designed for the highest
performance – providing hours of reliable operation.
Thanks to the low noise level of the ESM 2–5 range, the
compressor can be installed at the point of use – requiring no
additional cost for a separate compressor room or expensive
pipework.
ESM 2 – 5: The sound of silence

Technical Data ESM 2 – 5


Type Maximum Volume flow 1) Motor power Net Noise Dimensions in mm (L x W x H)
pressure1) weight 2) level 3) Standard Complete Compressor Station 2)
Compressor
bar psig m3/min cfm kW hp kg dB(A) mm mm
ESM 2 10 145 0.24 9 2.2 3 100 61 620 x 600 x 840
ESM 2–200 10 145 0.24 9 2.2 3 165 61 1450 x 600 x 1355 (200 l receiver)
ESM 3 10 145 0.36 13 3 4 100 61 620 x 600 x 840
ESM 3–200 10 145 0.36 13 3 4 165 61 1450 x 600 x 1355 (200 l receiver)
ESM 4 10 145 0.53 19 4 5.5 105 62 620 x 600 x 840
ESM 4–200 10 145 0.53 19 4 5.5 170 62 1450 x 600 x 1355 (200 l receiver)
ESM 4–500 10 145 0.53 19 4 5.5 255 62 1950 x 680 x 1520 (500 l receiver)
ESM 5 10 145 0.67 24 5.5 7 105 66 620 x 600 x 840
ESM 5–200 10 145 0.67 24 5.5 7 170 66 1450 x 600 x 1355 (200 l receiver)
ESM 5–500 10 145 0.67 24 5.5 7 255 66 1950 x 680 x 1520 (500 l receiver)
1)
Capacity and power measurements according to ISO 1217, ed. 3, Annex C – 1996 test code. Measured at maximum pressure without any options.
2)
Total weight of complete compressor station on 200 l receiver: ESM 2 – ESM 3 = 212 kg, ESM 4 = 213 kg, ESM 5 = 217 kg
3)
Noise values determined according to ISO 2151; Tolerance ± 3dB(A)

Standard Equipment Optional Equipment


• DOL starting • ESM 4 – ESM 5 available with Start/Delta starting
• Overload relay motor protection and AirBasic controller

• Start/Stop control with pressure switch • ESM 4 – ESM 5 with a larger 500 ltr receiver

• On/Off switch • Prefilter and microfilter combination

• Electric motors, IP55, F-class insulation • Timed or float drains for receiver mounted units

• Oil level monitoring, sight glass • Refrigerant dryer ESM 2 –5


Guaranteed best performance combined with low
• Belt transmission pressure losses
• Safety devices for: • 3°C dew point at 25°C ambient temp. (ISO 7183)
– Motor over temperature • Environmentally friendly refrigerant R134a
– Compressor over temperature, trip at 110°C • Digital controller displaying:
– Compressor over pressure (safety valve) – Dew point indication
– Additional energy saving mode
• Running condition indicators:
– Maintenance display
– Pressure
– Fault memory
– Hour-meter
• Epoxy powder coated enclosure
• Oil thermostat
• Factory filled with AEON lubricant

For additional information please contact Gardner Denver or your local representative.

info.tampere@gardnerdenver.com
571 · E · 0609 · B&N

www.gardnerdenverproducts.com

Specifications subject to change without notice.


Copyright 2009 Gardner Denver.